Oval Wheel Meter OV Series with Pulse Pick
Transcription
Oval Wheel Meter OV Series with Pulse Pick
Oval Wheel Meter with Pulse Pick-Ups with Resistance and Temperature Thermometer OV Series AG 54 PT 100 Operating manual Bopp & Reuther Messtechnik GmbH Am Neuen Rheinhafen 4 67346 Speyer Germany Phone : +49 (6232) 657-0 Fax: +49 (6232) 657-505 [email protected] www.bopp-reuther.de A-EN-01231-00Rev.E 12/2013 Page 1 of 20 Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 Operating manual Table of Contents Foreword ....................................................................................................................................................... 4 I. Transport, Delivery, Storage ...................................................................................................................... 4 II. Warranty ................................................................................................................................................... 4 III. General safety instructions ...................................................................................................................... 4 IV. Special instructions ................................................................................................................................. 5 1. Identification.............................................................................................................................................. 6 2. Area of Application.................................................................................................................................... 6 3. Principle of Operation and System Design ............................................................................................... 6 3.1 Measuring Principle............................................................................................................................. 6 3.2 System Design .................................................................................................................................... 7 4. Input .......................................................................................................................................................... 7 4.1 Measured Variable .............................................................................................................................. 7 4.2 Measuring Range ................................................................................................................................ 7 5. Output ....................................................................................................................................................... 8 5.1 Output Signal ...................................................................................................................................... 8 5.1.1 OV 800 with Pulse Pick-Up AG 54 ............................................................................................... 8 5.1.2 OV 1000 with Pulse Pick-Up AG 54 ............................................................................................. 8 5.2 Electrical and Thermal Safety Relevant Data ..................................................................................... 8 6. Characteristic Values ................................................................................................................................ 9 6.1 Reference Conditions.......................................................................................................................... 9 6.2 Tolerated Deviation ............................................................................................................................. 9 6.3 Repeatability ....................................................................................................................................... 9 6.4 Influence of the Ambient Temperature................................................................................................ 9 6.5 Influence of the Measuring Temperature ............................................................................................ 9 7. Operating Conditions ................................................................................................................................ 9 7.1 Installation Conditions ......................................................................................................................... 9 7.1.1 Installation Instructions ................................................................................................................. 9 7.1.1.1 General Information ............................................................................................................... 9 7.1.1.2 Installation ............................................................................................................................ 10 7.1.2 Start-Up Conditions .................................................................................................................... 10 7.2 Ambient Conditions ........................................................................................................................... 11 7.2.1 Ambient Temperature................................................................................................................. 11 7.2.2 Storage Temperature ................................................................................................................. 11 7.2.3 Degree of Protection .................................................................................................................. 11 7.2.4 Electromagnetic Compatibility .................................................................................................... 11 7.3 Process Conditions ........................................................................................................................... 12 7.3.1 State of Aggregation................................................................................................................... 12 7.3.2 Viscosity ..................................................................................................................................... 12 7.3.3 Liquid Temperature Limits .......................................................................................................... 12 7.3.4 Liquid Pressure Limits ................................................................................................................ 12 7.3.5 Flow Rate Limits ......................................................................................................................... 12 7.3.6 Pressure Loss ............................................................................................................................ 12 8. Constructive Design................................................................................................................................ 13 8.1 Model/Dimensions............................................................................................................................. 13 8.2 Weight ............................................................................................................................................... 13 Page 2 of 20 Details subject to change. A-EN-01231-00Rev.E Bopp & Reuther Messtechnik GmbH Operating manual Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 8.3 Material ............................................................................................................................................. 14 8.4 Process Connection .......................................................................................................................... 14 8.5 Electrical Connection ........................................................................................................................ 15 9. General ................................................................................................................................................... 16 10. Certificates and Approvals .................................................................................................................... 16 Appendix ..................................................................................................................................................... 17 A. Troubleshooting...................................................................................................................................... 17 B Maintenance, Cleaning, Changing the Indicator ..................................................................................... 18 B.1 Maintenance, Cleaning ..................................................................................................................... 18 B.2 Repairs, Hazardous Substances ...................................................................................................... 18 C. Forms ..................................................................................................................................................... 19 C.1 Certificate of Non-Objection for the Contractor ................................................................................ 19 D. Certificates ............................................................................................................................................. 20 D.1. EC Type Examination Certificate Directive 94/9/EC ....................................................................... 20 PTB 00 ATEX 2048 X (Sept.2000) ......................................................................................................... 20 D.1. 1. 1st Supplement (Aug.2002)........................................................................................................ 20 D.1. 2. 2nd Supplement (July 2004) ...................................................................................................... 20 D.1. 3. 3rd Supplement (Oct. 2005) ....................................................................................................... 20 D.1. 4 4th Supplement (Mai 2011) ........................................................................................................ 20 D.2. EC Type Examination Certificate Module B Directive 97/23/EC (July 2005) .................................. 20 D.3. EC-Conformity declaration (Sept. 2013) ......................................................................................... 20 Bopp & Reuther Messtechnik GmbH A-EN-01231-00Rev.E Details subject to change. Page 3 of 20 Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 Operating manual Foreword I. Transport, Delivery, Storage Always protect devices against humidity, soiling, impacts and damages Delivery Inspection: Check the delivery for completeness upon receipt. Compare the device data with the data on the delivery note and in the order records. Report any in-transit damage immediately. Damage reported at a later date shall not be recognized. II. Warranty Please refer the contractual terms and conditions relating to delivery for the scope and period of warranty. Warranty claims shall be conditional to correct installation and commissioning in accordance with the operating instructions of the device. The necessary installation, commissioning and maintenance work should only be carried out by qualified and authorized personnel.. III. General safety instructions 1. Oval Wheel Meters are reliable, high accurate volumetric measuring devices. They should only be used for their intended purpose. Always observe the pressure and temperature limits stated on the type plate, as well as all other technical data and safety information during device installation, start-up and operation. 2. Always observe national and international regulations concerning the operation of devices and systems under pressure. 3. Prior to installation, the operator has to ensure that the pressure bearing parts have not been damaged during transportation. 4. The devices have to be installed, operated and serviced by qualified personnel. The operator has the responsibility to ensure that the personnel have received sufficient and appropriate training. In cause of doubt, please contact the manufacturer. 5. The operator must ensure that the materials used (wetted parts) of the device compared with the measured liquid are chemically resistant. 6. The gaskets or sealing elements must be handled with care according to the operating instructions. 7. The tightening torques for the screw connections at the cover and lower part of the housing, as well as for the flange connections in the pipework are available on request. 8. The sensors (for the pulse pick-up and, if necessary, for the temperature measurement) should only be replaced once it has been ascertained that the meter is depressurised. 9. Symbols used Warning! Failure to observe this warning can lead to injury of persons or a security risk. Attention! Non-compliance can lead to faulty operation or damage to the device. Page 4 of 20 Details subject to change. A-EN-01231-00Rev.E Bopp & Reuther Messtechnik GmbH Operating manual Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 IV. Special instructions Observe the tightening torques below for the screw connections at the cover and lower part of the housing, as well as for the flange connections in the pipework. Type OV 800 OV 1000 Bopp & Reuther Messtechnik GmbH Pressure stage PN 16 PN 16 Tightening torque [Nm] 90 90 A-EN-01231-00Rev.E Nut size M 16 M 16 Details subject to change. Page 5 of 20 Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 Operating manual 1. Identification Manufacturer Bopp & Reuther Messtechnik GmbH Am Neuen Rheinhafen 4 67346 Speyer, Germany Phone : ++ 49 (0) 6232 657-0 Fax : ++ 49 (0) 6232 657-505 Type of product Direct volumetric meter (filling meter) Product name OV oval wheel meters with pulse pick-ups AG 54 and optional resistance thermometer PT100 A-DE-01231-00Rev.E Version no. 2. Area of Application The quantity control of certain industrial liquids is an economic necessity considering the high value of these products. The design and materials of the volume measuring instruments required for these procedures have to be adapted to the particular operating conditions and characteristics of the liquids to be measured. The area of application for OV oval wheel meters includes the measuring, metering and controlling of liquids. OV oval wheel meters meet all these requirements. They are mainly used for measuring liquid gases, benzines (white products) and mineral oils. OV oval wheel meters are manufactured with the nominal sizes 80 and 100 mm and can be used up to PN 16 with a max. operating temperature of up to 60 °C. OV oval wheel meters are extremely versatile, e.g. in the petrochemical industry for loading tank trucks and oil tankers. 3. Principle of Operation and System Design 3.1 Measuring Principle Oval Wheel Meter belong to the group of direct volumetric meters for liquids with movable partition walls (displacement flow meters). The Oval Wheel Meter consists of a measurement chamber housing with two pivoted oval wheels which are toothed and roll off each other in counter-rotations. The diagram displays oval wheel movement during the measurement process. Each revolution the oval wheels displaces a discrete volume of liquid (defined by the space between the oval wheel and measurement chamber) through the chamber. Measurements are transmitted via a flag disk, which is attached to an oval wheel meter, to an inductive sensor. Page 6 of 20 Details subject to change. A-EN-01231-00Rev.E Bopp & Reuther Messtechnik GmbH Operating manual Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 3.2 System Design The oval wheel meters consist of the following components: Meter: Measurement of the liquid volume or the volumetric flow rate occurs via an oval wheel positive displacement meter. Rotation of the oval wheel meter is sensed via the pulse pick-up. Pulse pick-up AG 54: The pulse pick-up consists of two standard inductive proximity switches with NAMUR output in accordance with DIN EN 60947-5-6 and a slot disk attached directly to one of the oval wheels. The slots are distributed around the circumference of the disk in such a way that volume proportional pulses are generated. The pick-up operates wear-resistant. Since the pulse pick-up provides NAMUR signals directly, separate pre-amplifier electronics are not required. These signals are processed and evaluated in suitable flow computers. Approval symbol for pulse pick-up AG54: II 1G Ex ib II C T6 Resistance thermometer PT100: The resistance measured by the PT100 is evaluated by appropriate evaluating units. The screwed resistance thermometer PT100 has a temperature range of between –40 and 100°C. The PT100 is located in a threaded, protective sleeve, its basic values have been engineered in accordance with DIN EN 60751 and it is connected via 4-wire technology. (Approval symbol for PT100: According to the manufacturer’s declaration in accordance with VDE 0165/Section 6.1.3.1.3 or EN 60079-11 a type test is not required). These temperature sensors are passive electrical equipment. 4. Input 4.1 Measured Variable Liquid volumes and volumetric flow rate 4.2 Measuring Range Measurement range for media with Newtonian flow properties, applicable to oval wheel meters with plain bearings Type DN Flow rate: Qmax [ℓ /min] OV 800 80 1500 OV 100 1000 3333 Min Max Cont. operation Batch operation Min Max Cont. operation Batch operation Liquid gas < 3.5 mPas > 3.5 mPas [m³/h] 10 80 54 72 20 180 140 140 [m³/h] 2.4 90 54 7.2 5.3 200 140 140 [m³/h] 1.8 90 75 90 4 200 180 180 The values in the table are general nominal ratings. The exact range depends on the measured media, viscosity and type of meter and is listed in the data sheet. Bopp & Reuther Messtechnik GmbH A-EN-01231-00Rev.E Details subject to change. Page 7 of 20 Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 Operating manual 5. Output 5.1 Output Signal 5.1.1 OV 800 with Pulse Pick-Up AG 54 Technical data (OV800) Number of pulses per rotation 10 (4 pulses/litre) Type of proximity switch NJ 1.5-18GM-N-D Switching element function NAMUR opener Switching frequency 0 – 400 Hz Permissible ambient temperature -25 to + 85°C (248 to 358K) Approval PTB 00 ATEX 2048 X Standard conformity DIN EN 60947-5-6 EMC in accordance with EN 60947-5-2 System of protection IP 65 II 1G Ex ia IIC T6 Ex-protection Hydraulic compressive strength 350 bar dynamic Connection of external devices In compliance with EN 50227 (NAMUR) and explosive approval 5.1.2 OV 1000 with Pulse Pick-Up AG 54 Technical data (use with OV1000) Number of pulses per rotation 15 (2.085 pulses/litre) Type of proximity switch NJ 1.5-18GM-N-D Switching element function NAMUR opener Switching frequency 0 – 400 Hz Permissible ambient temperature -25 to + 85°C (248 to 358K) Approval PTB 00 ATEX 2048 X Standard conformity DIN EN 60947-5-6 EMC in accordance with EN 60947-5-2 System of protection IP 65 II 1G Ex ia IIC T6 Ex-protection Hydraulic compressive strength 350 bar dynamic Connection of external devices In compliance with EN 50227 (NAMUR) and explosive approval 5.2 Electrical and Thermal Safety Relevant Data See Appendix EC Type Examination Certificates Page 8 of 20 Details subject to change. A-EN-01231-00Rev.E Bopp & Reuther Messtechnik GmbH Operating manual Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 6. Characteristic Values 6.1 Reference Conditions Oval wheel meters are calibrated at PTB1 approved test benches. Pressure: 2 to 7 bar. Temperature: 20 to 30°C 6.2 Tolerated Deviation OV800, OV1000: ± 0.1% (1:10) 6.3 Repeatability < 0.05% 6.4 Influence of the Ambient Temperature < 0.005% / °C 6.5 Influence of the Measuring Temperature Negligible 7. Operating Conditions 7.1 Installation Conditions 7.1.1 Installation Instructions Warning! Before mounting and operating the device, carefully read and observe the installation instructions. Before mounting or disassembling the device, depressurize and cool down the system. 7.1.1.1 General Information 1 Only trained personnel who have received authorisation from the system owner are allowed to carry out assembly, electrical installation, start-up, maintenance, and operation. They should have read and fully understood the operating instructions and always follow the information contained therein. Bopp & Reuther oval wheel meters are precision flow meters. Input and output ports are closed to prevent impurities entering the device. Only remove protective caps immediately prior to operation. Observe operating data marked on the oval wheel meters and data in the order confirmation and on the data sheet. If you wish to use the device under different operating conditions, please consult Bopp & Reuther Messtechnik GmbH in advance, always state the serial number. Install the oval wheel meter in the pressure pipe behind the pump. (Approx. 3 m liquid column pressure loss for nominal flow rate). Install the oval wheel meter in a way that it remains completely filled with liquid even when idle. In order to prevent measuring errors due to trapped gas or soiling etc., the user should take appropriate preventative measures (gas separator, strainer). Physikalisch-Technische Bundesanstalt, the German national metrology institute Bopp & Reuther Messtechnik GmbH A-EN-01231-00Rev.E Details subject to change. Page 9 of 20 Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 Operating manual 7.1.1.2 Installation Remove any impurities from the pipework. For this task, install a fitting part instead of the oval wheel meter and flush the pipe. Only remove the protective caps at the oval wheel meter’s input and output ports immediately prior to installation. Prevent any impurities entering the device during installation. The arrows on the oval wheel meter housing indicate the direction of flow. The oval wheel meter’s housing cover has to be vertical to ensure that the oval wheel axles are positioned horizontally, irrespective of the pipework. Install the oval wheel meter strain-free. The sensor can be used together with the pulse pick-up AG 54 according to the type of protection “intrinsically safe” in potentially explosive areas. AG 54 PTB 00 ATEX 2048 II 1G Ex ia IIC T6 EMC protection can only be guaranteed with shielded wires. Shielding has to be applied in the metal PG connecting bolts. 7.1.2 Start-Up Conditions Important Start up the oval wheel meter with a gradually increasing flow rate. In measuring systems for viscous liquids which require heating, switch on the heating system of the oval wheel meter, filter and pipework in sufficient time prior to start-up, subsequently start up the device with a gradually increasing flow rate. Type plates with pressure relevant information Additional type plate at the flange connection with CE0036 mark. The used abbreviations have the following meaning: PT: Achieved test pressure and test date PT 1-40-70288-550/a bar Bopp & Reuther Messtechnik 0036 Page 10 of 20 D-67346 Speyer Details subject to change. A-EN-01231-00Rev.E Bopp & Reuther Messtechnik GmbH Operating manual Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 7.2 Ambient Conditions 7.2.1 Ambient Temperature OV800 with AG 54: OV1000 with AG 54: -10 to +80 °C -10 to +80 °C 7.2.2 Storage Temperature OV: Pulse pick-up: -25° C to +100 °C -25° C to +85 °C 7.2.3 Degree of Protection OV800 with AG 54: IP67 OV1000 with AG 54: IP67 According to EMC / EN 60529-5-6 7.2.4 Electromagnetic Compatibility According to EMC directive 94/9/EG, EN 60079-0; EN 60079-11 The "electromagnetic compatibility" can only guaranteed if the cover is closed. If the cover is open, interferences can arise due to EMC signal pick-up. Bopp & Reuther Messtechnik GmbH A-EN-01231-00Rev.E Details subject to change. Page 11 of 20 Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 Operating manual 7.3 Process Conditions 7.3.1 State of Aggregation Suitable for liquids 7.3.2 Viscosity OV800, OV1000: 0.3 - 150 mPas 7.3.3 Liquid Temperature Limits 60°C 7.3.4 Liquid Pressure Limits DN 80 PN 16 B2 DN 100 PN 16 7.3.5 Flow Rate Limits All details in l/min OV800 OV1000 1500 3300 7.3.6 Pressure Loss OV1000 OV800 0.5 0.5 0.4 0.4 2.6 mPas 0.3 Pressure loss [bar] 2.6 mPas 0.3 Pressure loss [bar] 0.2 0.2 0.1 0.1 Druckverlust in [bar] Druckverlust in [bar] 0 0 0 40 80 120 160 200 Flow rate Q [m³/h] Page 12 of 20 0 20 40 60 80 100 Flow rate Q [m³/h] Details subject to change. A-EN-01231-00Rev.E Bopp & Reuther Messtechnik GmbH Operating manual Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 8. Constructive Design 8.1 Model/Dimensions OV800 AG 54: 248 405 176 550 270 OV1000 AG 54 248 480 258 650 334 8.2 Weight Type Nominal size Weight [kg] Bopp & Reuther Messtechnik GmbH OV 800 DN 80 155 OV 1000 DN 100 260 A-EN-01231-00Rev.E Details subject to change. Page 13 of 20 Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 Operating manual 8.3 Material B 2 Housing Oval wheels Measuring area – cover panel Sliding disk Bearing • Cast steel Brass Aluminium Hard. carbon Materials • • • • 8.4 Process Connection Flanges DIN EN 1092-1 form B1, PN 16 DIN 2545 C, PN 16 ANSI 150 ANSI 300 (drilled acc. to PN16) Page 14 of 20 OV 800 OV 1000 x x x x x Details subject to change. A-EN-01231-00Rev.E Bopp & Reuther Messtechnik GmbH Operating manual Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 8.5 Electrical Connection The electrical connections are located underneath the sensor cover. AG 54 and PT 100: Resistance thermometer Pt100 L- L+ Sensor no. 2 L- brown 10 11 12 blue 9 brown 8 blue red +I 7 L+ not occupied +U 6 not occupied -U 5 not occupied -I 4 red 3 white 2 white not occupied 1 Sensor no. 1 Warning! The pulse pick-up AG 54 and the resistance thermometer sleeve or the drain plug should not be replaced when the oval wheel meter is pressurised (housing cover is under medium pressure). Attention! / Warning! Always observe the respective national installation regulations when installing in potentially explosive areas (for Germany: EN 60079-14 or VDE 0165). Bopp & Reuther Messtechnik GmbH A-EN-01231-00Rev.E Details subject to change. Page 15 of 20 Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 Operating manual 9. General The meters are factory set to the operating conditions specified in the order. See the enclosed configuration data sheet for the set values. 10. Certificates and Approvals Approval for official calibration: OV 800: 5.241/01.55 OV 1000: 5.241/03.57 Electromagnetic compatibility according to EN 60947-5-2, EN EN 60947-5-6 Pulse pick-up AG 54: PTB 00 ATEX 2048 II 1G Ex ia IIC T6 Resistance thermometer PT 100: According to the manufacturer’s declaration in accordance with VDE 0165/Section 6.1.3.1.3 or EN 60079-11 a type test is not required. These temperature sensors are passive electrical equipment. The basic health and safety requirements are fulfilled due to compatibility with: EN 60079-0 General Provisions EN 60079-11 Intrinsic safety "i" CE Mark: The measuring system fulfills the legal requirements of the EC Directives 2004/108/EG and 94/9/EG including all published revisions or amendments to date. Bopp & Reuther Messtechnik GmbH confirms successful device testing and affixing of the CE Mark. The device fulfils the requirements of standards EN1127-1 and En13463-1 according to ATEX 100a. The owner has to observe respective regulations and directives when installing and connecting the device in potentially explosive areas. Pressure equipment directive 97/23/EG The OV oval wheel meters are suitable for group 1 liquids (classification acc. to Category III, Module B and C1) Page 16 of 20 Details subject to change. A-EN-01231-00Rev.E Bopp & Reuther Messtechnik GmbH Operating manual Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 Appendix A. Troubleshooting Oval wheel meters with pulse pick-ups and mechanical counters work maintenance-free. However, if a fault should occur or there is suspicion of incorrect measuring, the following instructions offer help in identifying the cause of possible faults and provide hints to eliminate the problems. Warning! Always observe local regulations and all the safety instructions in these operating instructions when carrying out work at electrical connections. Always observe the information and regulations contained in the explosive documentation guidelines when working with potentially explosive devices. Possible faults and their remedies are described below. General: If the fault cannot be detected, please contact the service department of Bopp & Reuther Messtechnik GmbH or return the device for repair work to Bopp & Reuther Messtechnik GmbH (see Appendix B2). Bopp & Reuther Messtechnik GmbH A-EN-01231-00Rev.E Details subject to change. Page 17 of 20 Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 Operating manual B Maintenance, Cleaning, Changing the Indicator B.1 Maintenance, Cleaning If the oval wheel meter is to be shut down for a longer period, it should be de-installed, cleaned thoroughly and coated with an acid-free oil. Cover the input and output ports with protective caps. Ensure that the oval wheel meters are stored in a dry room. B.2 Repairs, Hazardous Substances Before sending the Oval Wheel Meter to Bopp & Reuther Messtechnik GmbH, make sure to observe the following: Attach a note describing the malfunction, state the application field and the chemical/physical properties of the media (please find the respective form in appendix) Remove all residues of the media and pay special attention to sealing grooves and slits. This is of extreme importance if the medium is hazardous to health, i.e. caustic, toxic, carcinogenic or radioactive etc. Please do not return the device if you are not perfectly sure that all media hazardous to health have been cleaned off. Costs incurred due to inadequate cleaning of the device and possible costs for disposal and/or personal injuries (causticization etc.) will be billed to the operating company. Please ask our customer service for help and advice if your Oval Wheel Meter does not work properly: Bopp & Reuther Messtechnik GmbH Service Am Neuen Rheinhafen 4 67346 Speyer Telefon: +49 (6232) 657-402 Fax: +49 (6232) 657-561 Bopp & Reuther Messtechnik GmbH Werkstatt Karlskron Münchener Str. 23 85123 Karlskron Gewerbegebiet Brautlach, an der B 13 Telefon: +49 (8450) 928330 Fax: +49 (8450) 928332 Mobile: +49 (172) 638 5022 Warning! The pulse pick-up AG 54 and the resistance thermometer PT 100 or the drain plug should not be replaced when the oval wheel meter is pressurised (housing cover is under medium pressure). Page 18 of 20 Details subject to change. A-EN-01231-00Rev.E Bopp & Reuther Messtechnik GmbH Operating manual Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 C. Forms C.1 Certificate of Non-Objection for the Contractor Unbedenklichkeitsbescheinigung für Auftragnehmer / Certificate of non-objection for contractor Fiche de Renseignements / Confirmación de no objeción para mandatarios Kunde / Client / Client / Cliente:.............................................................................................................. Gerätetyp und Gerätenr.: Meter type and Serial No.: Compteur / No. de série Datum: Date: Date: Data: Auftragsnr. / Lieferschein: Order No.: / Delivery note: No. d’ ordre / Bordereau de livraison: N° da encomenda / Guia de Remessa: ............................................................... .................................................... ................................................. .................................................. Auftragstext / Order text / Caractéristiques / Características: ................................................................ ............................................................ ............................................................... ................................................................ ............................................................ ............................................................... ATTENTION – GEFAHREN –HINWEISE – ATTENTION - ATENÇÃO Letzter Stoff / Last medium / Dernier liquide mesuré / Último fluido medido: ............................................................................................... Gerät entleert / Unit drained / Vidangé complètement / Aparelho completamente esvaziado? Eigenschaften angeben! z.B. ätzend, brennbar, giftig State characteristics! i.e. corrosive, flammable, toxic Identification des dangers! p.e. corrosif, inflammable, toxique Indicar características, como p.ex. corrosivo, inflamável, venenoso ja / yes / oui / sim nein / no / non / não ............................................................................................ Spülung mit / drained with / liquide de rinage / Líquido usado ............................................................................................ para a lavagem: ............................................................................................... ............................................................................................ Restverschmutzung / rest of medium / impuretés restantes / Sujidade remanescente? ............................................................................................ ja / yes / oui / sim nein / no / non / não ............................................................................................ ............................................................................................ SCHUTZMASSNAHMEN – PROTECTION MEASURES- MESURES DE PROTECTION - MEDIDAS DE PROTECÇÃO nein / no / non / não Handschuhe / gloves / gants / luvas Schutzanzug / protection suit/ tenue de sécurité / vestuário de protecção Gestellbrille / eye glasses/ lunettes / Óculos de protecção Korbbrille und Gesichtsschutz / Glasses with face protection/ Lunettes avec protection du visage / Óculos com protecção para o rosto Schutzmaßnahmen/protection measures/mesures de protection / medidas de protecção ja / yes / oui / sim Atemschutz / respirator / appareil respiratoire / Aparelho respiratório Mit Absaugungsarbeiten / extractor cowl / travailler sous hotte aspirante / Trabalhar com aspiração Besondere Schutzmaßnahmen / special protection / mesures de protection Particulières / medidas especiais de protecção Bite angeben / please state / à préciser / Favor indicar………………………………………………………............................................................................. Beauftragter / Mandatory / Mandataire / Mandatario: Name in Druckbuchstaben/name in printed letters/ nom en lettres capitales / Encarregado (Nome em maiúsculas)...................................................…………………....................... Ort und Datum / place and date / lieu et date / Local de data: Unterschrift / signature / signature / assinatura: ....................................................................... ................................................................................................ Bopp & Reuther Messtechnik GmbH A-EN-01231-00Rev.E Details subject to change. Page 19 of 20 Oval Wheel Meter OV with Pulse Pick-ups AG54, with PT100 Operating manual D. Certificates D.1. EC Type Examination Certificate Directive 94/9/EC PTB 00 ATEX 2048 X (Sept.2000) D.1. 1. D.1. 2. D.1. 3. D.1. 4 1st Supplement (Aug.2002) 2nd Supplement (July 2004) 3rd Supplement (Oct. 2005) 4th Supplement (Mai 2011) D.2. EC Type Examination Certificate Module B Directive 97/23/EC (July 2005) D.3. EC-Conformity declaration (Sept. 2013) Page 20 of 20 Details subject to change. A-EN-01231-00Rev.E Bopp & Reuther Messtechnik GmbH