pop-up series
Transcription
pop-up series
POP-UP SERIES TECHNICAL DOCUMENTATION SUMMARY 1. Presentation of the Power Moller ® product range......................3 2. Presentation of «Pop-Up»...........................................................4-5 Structure Operating principle Bottom surface of load to be conveyed General technical data 3. Transfer capacity..........................................................................6-9 Speed and rate of load transfer, zone by zone, in isolated singulation mode Speed and rate of load transfer in train mode 4. Installation of the module.............................................................10-15 Assembly principle Dimensions Dimensions of circuit boards 5. POP-UP control...........................................................................16-20 Timing principal for controls Control principle by PLC Connection of circuit boards CBM-105 and CBR-305 Parameter settings 6.Element replacement....................................................................21-22 Replacement of free roller, belt and motorized roller (M1) for straight conveyor Replacement of diverter wheel Replacement of round belt for driving diverter wheels 7. Replacement parts.......................................................................23 Standard Pop-Up references List of accessories Replacement of round and ribbed belts for driving of diverter wheel Annex 1 - Declaration of incorporation.................................................25 POP-UP SERIES TECHNICAL DOCUMENTATION 2 Dated 21/07/2016 1 - PRESENTATION OF THE POWER MOLLER® PRODUCT RANGE (ඔඍඋගකඖඑඋ උ උ 0ගකඑජඍඌකඔඔඍකඛ Standard circuit board AC Induction CB018 CB016 0ඌඝඔඍ 90° transfer DC Brushless HBR605 Ø50 CB016B F-RAT-S PM500 BS (K) 150 PM500 BU (KU) 150 PM500 BS-B (KB) 150 CB030 CBM-105 CBR-305 45° transfer CBM-105 External circuit board ZPA circuit board HB510 Integrated circuit board Ø32 HB510B Ø50 PM320 HS (32HS) HBK-608 LCX-901 50 CB018 Module circuit board PM500 ME PM500 XE Ø50 HBR-605 CBM-105 CBR-305 POP-UP PM500 FE (50E) 300 CBM-105 HB510 PM500 FE-B (50EB) 300 CB016B HB510B PM605 FE (60E) 500 CBM-105 HB510 PM605 FE-B (60EB) 500 CB016B HB510B PM605 KT 1000 CB030 HBK-608 50 LCX-901 300 LCX-901 500 LCX-901 Ø60,5 PM605 XE (60XE) Ø60,5 Corresponding circuit board Max load to be conveyed (60E) Former part number Mechanical brake version POP-UP SERIES TECHNICAL DOCUMENTATION 3 Dated 21/07/2016 2. PRESENTATION OF «POP-UP» Itoh-Denki Pop-Up transfer modules use 24V DC Brushless Motorized Roller technology in a very compact « cassette » structure. This makes it easy to integrate into both new and reconditioned conveyors. It can be used on conveyor lines for order picking, distribution or on assembly lines to adapt to your logistics changes. STRUCTURE Size D, transfer left Motorized roller for diverter (M2) Motorized roller for lifting (M3) Diverter wheel Protective cover l Motorized roller for straight conveyor (M1) L Free roller Circuit boards Ribbed belt CBR-305 CBM-105 OPERATING PRINCIPLE This diverter module works with three brushless motorized rollers, at very low voltage (24 V DC), without pneumatic or other types of energy. The transfer works using the up and down PRYHPHQW RI WKH ZKHHO GHÀHFWRU 1R PRUH than two motors function at any one time, and don’t exceed 147W in nominal operation. Rollers Diverter wheels raised Diverter wheels Diverter wheels lowered BOTTOM SURFACE OF LOAD TO BE CONVEYED 7KH³SRSXS´WUDQVIHUFDVVHWWHLVGHVLJQHGIRUÀDWERWWRPHGSDFNDJHVZLWKRXWHGJHVRUJURRYHV POP-UP SERIES TECHNICAL DOCUMENTATION 4 Dated 21/07/2016 GENERAL TECHNICAL DATA Size Width W (mm) Dimension WxLxH (mm) A B C D 394 494 594 694 600 700 500x650 600x650 18 24 760 Length L (mm) 169 Height H (mm) Frame width mini (mm) Load dimensions WxL (mm) 400 500 Mini Max. 300x300 300x650 400x650 Max load to be conveyed (Kg) 30 1XPEHURIGLYHUWHUZKHHOV 14 18 1XPEHURIWUDQVIHUIUHHUROOHUV 7 Transfer angle 45° (30° option) Transfer direction Right or left (to be specify on order) Weight (Kg) Protective cover 46 Protected as standard Lower face To be planned To be planned Level difference transfer wheel-roller (mm) 3 Zinc-coated steel Frame ø50mm / Zinc-coated steel Roller Cable length (mm) 50mm for M1 and 100 mm for M2 and M3 Connector JST 9p male Circuit board for straight conveyor and diverter CBM-105-FP1-EU1 Circuit board for lifting CBR-305FP-B 313QRUPDOO\RSHQFRQWDFW9'&12 Proximity sensor Power supply Absorbed power Dimensions (mm) ø39,5 Material/hardness Polyurethane 90ShA Voltage 24VDC ± 10% On motor start-up 192W max 1RPLQDO 147W max Ambient temperature Environment Protection rating 0 to 40°C Humidity UHODWLYHKXPLGLW\ZLWKRXWFRQGHQVDWLRQ Vibration * Motorized roller IP54 IP20 Circuit board Extension cable (motorized roller - circuit board) Mounting support 24VDC supply unit Accessories (Optional) POP-UP SERIES 54 Straight conveyor: 60m/min max (adjustable) Diverter 45° : 90m/min max (adjustable) Speed Diverter wheels 51 Upper face Lateral faces Motorized rollers 49 TECHNICAL DOCUMENTATION 5 Dated 21/07/2016 3. TRANSFER CAPACITY SPEED AND RATE OF LOAD TRANSFER, ZONE BY ZONE, IN SINGULATION MODE Plastic box Diverter angle : 45° Straight transfer speed : 60m/min Divert transfer speed 45° : 90m/min Load 600x390mm 5000 t1 Package throughput / hour 4000 t0 3000 5kg 30kg 2000 1000 t2 0 0% 20% 40% 60% 80% 100% Transfer rate (%) Transfer rate (%) = t1 x 100 t0 Load 450x370mm 5000 Transfer capacity depends on dimension, bottom surface and material of the transported load, as well as speed, transfer mode, transfer rate... These curves are given as a guide. Package throughput / hour 4000 3000 5kg 30kg 2000 1000 0 0% 20% 40% 60% 80% 100% Transfer rate (%) Load 360x360mm 5000 Package throughput / hour 4000 3000 5kg 30kg 2000 1000 0 0% 20% 40% 60% 80% 100% Transfer rate (%) POP-UP SERIES TECHNICAL DOCUMENTATION 6 Dated 21/07/2016 Load 600x390mm t1 t0 5000 4000 Package throughput / hour Cardboard box Diverter angle : 45° Straight transfer speed : 60m/min Divert transfer speed 45° : 90m/min 3000 5kg 30kg 2000 1000 0 t2 0% 20% 40% 60% 80% 100% Transfer rate (%) Transfer rate (%) = t1 x 100 t0 Load 450x370mm 5000 Transfer capacity depends on dimension, bottom surface and material of the transported load, as well as speed, transfer mode, transfer rate... These curves are given as a guide. Package throughput / hour 4000 3000 5kg 30kg 2000 1000 0 0% 20% 40% 60% 80% 100% Transfer rate (%) Load 360x360mm 5000 Package throughput / hour 4000 3000 5kg 30kg 2000 1000 0 0% 20% 40% 60% 80% 100% Transfer rate (%) POP-UP SERIES TECHNICAL DOCUMENTATION 7 Dated 21/07/2016 SPEED AND RATE OF LOAD TRANSFER IN TRAIN MODE Plastic box Diverter angle : 45° Straight transfer speed : 60m/min Divert transfer speed 45° : 90m/min Load 600x390mm 5000 t1 Package throughput / hour 4000 t0 3000 5kg 30kg 2000 1000 t2 0 0% 20% 40% 60% 80% 100% Transfer rate (%) Transfer rate (%) = t1 x 100 t0 Load 450x370mm 5000 Transfer capacity depends on dimension, bottom surface and material of the transported load, as well as speed, transfer mode, transfer rate... These curves are given as a guide. Package throughput / hour 4000 3000 5kg 30kg 2000 1000 0 0% 20% 40% 60% 80% 100% Transfer rate (%) Load 360x360mm 5000 Package throughput / hour 4000 3000 5kg 30kg 2000 1000 0 0% 20% 40% 60% 80% 100% Transfer rate (%) POP-UP SERIES TECHNICAL DOCUMENTATION 8 Dated 21/07/2016 Load 600x390mm t1 t0 5000 4000 Package throughput / hour Cardboard box Diverter angle : 45° Straight transfer speed : 60m/min Divert transfer speed 45° : 90m/min 3000 5kg 30kg 2000 1000 0 t2 0% 20% 40% 60% 80% 100% Transfer rate (%) Load 450x370mm Transfer rate (%) = t1 x 100 t0 5000 Transfer capacity depends on dimension, bottom surface and material of the transported load, as well as speed, transfer mode, transfer rate... These curves are given as a guide. Package throughput / hour 4000 3000 5kg 30kg 2000 1000 0 0% 20% 40% 60% 80% 100% Transfer rate (%) Load 360x360mm 5000 Package throughput / hour 4000 3000 5kg 30kg 2000 1000 0 0% 20% 40% 60% 80% 100% Transfer rate (%) POP-UP SERIES TECHNICAL DOCUMENTATION 9 Dated 21/07/2016 4. INSTALLATION OF THE MODULE ASSEMBLY PRINCIPLE Width (W) 7KHFDVVHWWHW\SHVWUXFWXUHLVLQVHUWHGEHWZHHQWKHFRQYH\RUIUDPHDQG¿[HGWRWZREUDFNHWVZLWKWKHDLGRI four M8 screws. Optional mounting supports are available on request. Support Diverter wheel M1 Roller of staright conveyor 51.5 114 44.5 3 4×2 - ̨10 Cassette mounting hole 44.5 Support optional 40 2×4-M8 Support mounting hole 44.5 671 M2 M3 Support 760 The level of the straight conveyor, before and after the “pop-up”, should be aligned with the straight conveyor roller. 7KHOHYHORIWKHDQJOHGFRQYH\RUVKRXOGEHDOLJQHGZLWKWKHGHÀHFWRUUROOHU The lateral and lower parts of the transfer cassette are unprotected against mechanical risks. Appropriate protection should be applied depending on the structure and environment in which it will be installed and in accordance with local security regulations. Integration of the “pop-up” transfer cassette should be designed in order to enable easy insertion/extraction for maintenance purposes. 3 circuit board for the motorized rollers should be placed near the cassette with extension leads as required. POP-UP SERIES TECHNICAL DOCUMENTATION 10 Dated 21/07/2016 DIMENSIONS Size A - Transfer to left L 760 67 63 21 Proximity sensor Mounting position 2-250 100 Output cable M2 for diverter (100mm) 44.5 Mounting holes (4 - Ø8,4mm) Output cable M3 for lifting (100mm) 44.5 100 Level difference between wheels and rollers 3 Mounting position 2-671 94x6(=564) 8 3 7-∅ ∅5 169 0 Distance between level of transfer and support 01,4 W 394 Output sensor cable (50mm) Distance inside the frame Nominal width 400 Output cable M1 for straight conveyor (100mm) M2 for diverter M1 for straight conveyor M3 for lifting Size A - Transfer to right L 760 Output cable M2 for diverter (100mm) Mounting position 2-250 Output cable M1 for straight conveyor (100mm) 21 67 63 Output sensor cable (50mm) Proximity sensor 94x6(=564) 100 38 7-∅ ∅5 169 0 Level difference between wheels and rollers 3 Mounting position 2-671 Distance between level of transfer and support 101,4 44.5 44.5 Distance inside the frame Nominal width 400 Mounting holes (4 - Ø8,4mm) 100 W394 Output cable M3 for lifting (100mm) M2 for diverter POP-UP SERIES M3 for lifting M1 for straight conveyor TECHNICAL DOCUMENTATION 11 Dated 21/07/2016 Size B - Transfer to left L 760 Output cable M1 for straight conveyor (100mm) 75 63 67 21 Proximity sensor 44.5 Mounting holes (4 - Ø8,4mm) Output cable M3 for lifting (100mm) 44.5 100 Level difference between wheels and rollers 3 Mounting position 2-671 94x6(=564) 8 3 7-∅ ∅5 169 0 Distance between level of transfer and support 101,4 Output cable M2 for diverter (100mm) Distance inside the frame Nominal width 500 100 W 494 Mounting position 2-350 Output sensor cable (50mm) M2 for diverter M1 for straight conveyor M3 for lifting Size B - Transfer to right L 760 Output cable M2 for diverter (100mm) Mounting position 2-350 8 3 7-∅ 169 0 Level difference between wheels and rollers 3 94x6(=564) 100 ∅5 75 63 21 Proximity sensor Mounting position 2-671 Distance between level of transfer and support 101,4 W 494 44.5 67 Output sensor cable (50mm) Output cable M1 for straight conveyor (100mm) 44.5 Distance inside the frame Nominal width 500 Mounting holes (4 - Ø8,4mm) 100 Output cable M3 for lifting (100mm) M2 for diverter POP-UP SERIES M3 for lifting M1 for straight conveyor TECHNICAL DOCUMENTATION 12 Dated 21/07/2016 Size C - Transfer to left L 760 75 63 67 21 Proximity sensor Output cable M1 for straight conveyor (100mm) Distance inside the frame Nominal width 600 132 W 594 Mounting position 2-450 Output sensor cable (50mm) 44.5 Mounting holes (4 - Ø8,4mm) Output cable M3 for lifting (100mm) 44.5 100 Level difference between wheels and rollers 3 Mounting position 2-671 94x6(=564) 38 ∅5 7-∅ 169 0 Distance between level of transfer and support 101,4 Output cable M2 for diverter (100mm) M2 for diverter M1 for straight conveyor Size C - Transfer to right M3 for lifting L 760 Output cable M2 for diverter (100mm) W 594 169 Distance between level of transfer and support 101,4 8 3 7-∅ 0 75 63 94x6(=564) 100 ∅5 Level difference between wheels and rollers 3 21 Proximity sensor Mounting position 2-671 44.5 67 Output sensor cable (50mm) Output cable M1 for straight conveyor (100mm) 44.5 Distance inside the frame Nominal width 600 Mounting holes (4 - Ø8,4mm) Mounting position 2-450 Output cable M3 for lifting (100mm) M2 for diverter POP-UP SERIES M3 for lifting M1 for straight conveyor TECHNICAL DOCUMENTATION 13 Dated 21/07/2016 Size D - Transfer to left L 760 75 67 63 21 Proximity sensor Output cable M1 for straight conveyor (100mm) Distance inside the frame Nominal width 700 120 W 694 Mounting position 2-550 Output sensor cable (50mm) 100 94x6(=564) ∅38 ∅5 7- 169 0 Distance between level of transfer and support 101,4 44.5 Mounting holes (4 - Ø8,4mm) Output cable M3 for lifting (100mm) Level difference between wheels and rollers 3 Output cable M2 for diverter (100mm) Mounting position 2-671 44.5 M2 for diverter M1 for straight conveyor M3 for lifting Size D - Transfer to right L 760 Mounting holes (4 - Ø8,4mm) Output cable M2 for diverter (100mm) 38 7-∅ 75 169 0 Distance between level of transfer and support 101,4 63 94x6(=564) 100 ∅5 Proximity sensor Level difference between wheels and rollers 3 21 Mounting position 2-671 44.5 67 Output sensor cable (50mm) Output cable M1 for straight conveyor (100mm) 44.5 Distance inside the frame Nominal width 700 W 694 Mounting position 2-550 120 Output cable M3 for lifting (100mm) M2 for diverter POP-UP SERIES M3 for lifting TECHNICAL DOCUMENTATION M1 for straight conveyor 14 Dated 21/07/2016 CIRCUIT BOARD DIMENSIONS 78 38.5 47 4.5 4.5 0V 24V 3 23 23 3 5.PLS 4.ERR 3.V-IN 2.DIR 1.RUN 40 7 8 ERR/PWR 1. AUTO/MANU 2. INT/EXT 3. DIRECTION 4. E/N-OUT 5. SV-BRK 6. N/P-OUT VR1-ACC VR2-DEC 4.5 52 18 78 18 9 0 1 90 1 456 47 SPEED 23 38.5 M3:昇降用 0V 24V 23 90 1 CBR-305 5.PLS 4.ERR 3.V-IN 2.DIR 1.RUN 40 7 8 STATUS/ERR/PWR 1. SPEED L / H 2. INT/EXT 3. DIRECTION 4. E/N-OUT 5. N/P-OUT VR1-ACC 901 2 3 VR2-DEC SPEED 456 4.5 129 120 23 52 129 120 456 CBM-105 CBR-305 456 CBM-105 POP-UP SERIES TECHNICAL DOCUMENTATION 15 Dated 21/07/2016 5. POP-UP CONTROL TIMING PRINCIPAL FOR CONTROLS SN・R 5 Sensor 4 Sensor 3 4 1 2 SN・S 3 Sensor 0 M1 C/V M2 Sensor 6 Sensor 1 M3 Sensor 5 Sensor 2 TIMETABLE ༃ PLC IN Sensor 0 IN Sensor 1 IN Sensor 2 IN Sensor 3 OUT Motorized roller for straight conveyor (M1) OUT Motorized roller for diverter (M2) OUT Motorized roller for ůŝŌŝŶŐ (M3) ༄ ༅ ༆ ༇ RUN DIR IN Proximity sensor for diverter in lower posiƟon SN-S IN Proximity sensor for diverter in upper posiƟon SN-R Warning : ч 0,03s Warning : ч 0,03s :DUQLQJWKHWUDQVPLVVLRQWLPHIRUWKHVWRSVLJQDOVKRXOGEH¿[HGDWOHVVWKDQVHFRQGVIROORZLQJGHWHFWLRQRI VHQVRU616DQG615 PRINCIPLE CONTROL BY PLC POP-UP Motorized roller for straight conveyor M1 Motorized roller for diverter M2 Motorized roller for lifting M3 Straight conveyor Sensor for diverter can be operated in lower position SN-S when "ON" Sensor for diverter Diverter can be operated when "ON" in upper position SN-R POP-UP SERIES OUT M1 CBM-105 M2 CBM-105 OUT OUT TECHNICAL DOCUMENTATION CBR-305 IN CN2-1 Sensor 0 CN2-1 Sensor 1 CN2-1 M3 PLC CN2-2 Signal «RUN» for upstream conveyor Signal «RUN» for diverter Sensor 2 Sensor 3 Sensor 4 Sensor 5 Sensor 6 Signal «RUN» for straight conveyor 16 Dated 21/07/2016 CONNECTION OF CIRCUIT BOARDS CBM105 / CBR305 M1 M3 SN-S SN-R * *2 7 8 78 23 456 VR2 3 4 7 8 VR1-ACC VR2-DEC ERR/PWR 1. AUTO/MANU 2. INT/EXT 3. DIRECTION 4. E/N-OUT 5. SV-BRK 6. N/P-OUT 78 78 SPEED L / H 4 5 6 901 LED1 LED2 ACC 2 CN1 *1 Sensor extension cable (not provided) *2 Motorized roller extension cable (optional) 9 0 1 2 3 CBM-105 M2 1 0V 24V SW2 CN2 CBM-105FP1-EU1 VR1 9 0 1 90 1 M3 456 SW1 SPEED 6 4 5 6 DEC M3:昇降用 5.PLS 4.ERR 3.V-IN 2.DIR 1.RUN 23 VR2 3 4 23 ACC 2 1 CN1 901 LED2 VR1 2 3 7 8 9 0 1 CBR-305F□-B 2 3 SPEED L / H CN3 LED1 M1 CN3 CN2 CBM-105FP1-EU1 CBM-105 PM500FE series Speed code 17 2 CN2 CN3 PM500FC series Speed code 90 45 *11 * 456 * M2 PM500FE series 2 DEC SW1 CN1 SW2 Extension leads for the sensor and drive rollers should be placed in relation to the control panels, PLC, … Max motor cable length must not exceed 3m (i.e. motor cable + optional extension cable) D313YHUVLRQ&%0&%5 D131YHUVLRQ&%0&%5 &1 ▶ ▶ ◀ ◀ ◀ &1 Pulse signal Error signal Speed variation (0~10V) Direction of rotation Start / Stop Pulse signal Error signal ◀ ◀ Direction of rotation Start / Stop 0 VDC 0 VDC 24 VDC 24 VDC &1 POP-UP SERIES ▶ ▶ TECHNICAL DOCUMENTATION &1 17 Dated 21/07/2016 PARAMETERS SETTINGS 7 8 ERR/PWR 1. AUTO/MANU 2. INT/EXT 3. DIRECTION 4. E/N-OUT 5. SV-BRK 6. N/P-OUT VR1-ACC 7 8 78 18 78 0V 24V 23 456 VR2 SW1 9 0 1 90 1 23 VR1 VR2-DEC STATUS/ERR/PWR 1. SPEED L / H 2. INT/EXT 3. DIRECTION 4. E/N-OUT 5. N/P-OUT 0V 24V 5.PLS 4.ERR 3.V-IN 2.DIR 1.RUN SPEED 456 VR1-ACC M3:昇降用 2 3 23 VR2-DEC 901 90 1 18 CBR-305FP-B 5.PLS 4.ERR 3.V-IN 2.DIR 1.RUN SPEED 456 CBM-105 Circuit board for M3 456 Circuit board for M1 and M2 SW2 VR1 VR2 SW1 SW2 Ɣ TRANSFER TO LEFT Acceleration / Deceleration VR1 VR2 for straight conveyor Output error signal SW1-3 1 SW1-1 ON 2 3 4 SW1-3 SW2 ON 901 78 1 2 3 4 5 SW1-3 VR1 SW1-6 / NPN SW2 VR2 6 for lifting 1 2 3 4 5 OFF SW1-6 / PNP ON 6 901 23 M3 OFF 78 t2 456 for diverter t0 23 t1 M2 VR2 SW1-2 OFF 5 OFF VR1 Selection fixed speed 456 M1 Direction of rotation Do not change. Ɣ TRANSFER TO RIGHT Acceleration / Deceleration VR1 VR2 for straight conveyor Output error signal SW1-3 1 SW1-1 ON 2 3 4 SW1-3 SW2 ON 901 78 for diverter 1 2 3 4 5 SW1-6 / NPN SW2 VR2 6 OFF 1 2 3 OFF 4 5 SW1-6 / PNP ON 6 POP-UP SERIES TECHNICAL DOCUMENTATION 18 901 23 M3 for lifting 78 t1 SW1-3 VR1 456 M2 VR2 23 t2 VR1 SW1-2 OFF 5 OFF t0 Selection fixed speed 456 M1 Direction of rotation Do not change. Dated 21/07/2016 Change of direction of rotationPMdepending on the transfer direction 500 FE (50E) - PM 605 FE (60E) 2 3 4 5 3 6 12 3 45 1 5.PLS 4.ERR 3.V-IN 2.DIR 1.RUN 0V 24V 1 2 ON SW1 Circuit boards characteristics CBM-105 + PM500FE / FC Power supply CBR-305 + PM500FE 24 V DC ±10% Nominal voltage 24 V DC static Intensity 0,03 A nominal 2,9 A / 3,2 A 2,9 A start-up 4,0 A Connector 24V CN1 WRPP$:*a:$*2 Control connector CN2 WRPP$:*a:$*2 Cable dimension Time difference between the ON signal and the motor start Less than 15ms Fuse 6,3A Electrical protection Fuse7A Diode against wiring fault 95°C for circuit board Thermal protection 105°C for motor Current Limiter 4,0A Ambient temperature 0 to 40°C Humidity Lower than 90 % relative humidity without condensation Atmosphere 1RFRUURVLYHJDV Vibrations /HVVWKDQ* Installation Inside 1$ Automatic stop function After 10 pulses CBM-105 + PM500FE / FC (M1 and M2) Connector CN2 1 Start / Stop RUN/ STOP 2 Rotation direction CW/CCW DIR 3 Speed variation 0-10V 4 Error mode CBR305 + PM500FE (M3) Start up and stop motorized roller Input current 7.3mA at 24V Start : close contact Stop : open contact Start up and stop motorized roller Input current 13mA at 24V Start : close contact Stop : open contact Reverse direction of rotation of motorized roller Input current7.3mAat 24V Reverse direction of rotation of motorized roller Input current 13mA at 24V Speed variation by external analog voltage 0-10V on WHUPLQDORIFRQQHFWRU&1 Do not use Output error signal (open collector) ERROR Output 24V, 25mA maxi (adjust according to the control system with a resistance not included) 3URWHFWLRQZLWKUHVLVWDQFHRIȍ 5 Pulse PULSE POP-UP SERIES 2XWSXWSXOVHVLJQDO131VLJQDOE\RSHQFROOHFWRUVLJQDO131E\DQRSHQFROOHFWRUIRUDGMXVWLQJWKHRXWSXW voltage to 24V maxi and 25mA maxi (with a resistance and external power supply not provided) 3URWHFWLRQZLWKDUHVLVWDQFHRIȍ TECHNICAL DOCUMENTATION 19 Dated 21/07/2016 Setting of speed motorized roller for straight conveyor (M1) and motorized roller for diverter (M2) By SW1 and SW2 on circuit board CBM105-FP1-EU1 Do not change speed of motorized roller for lifting (M3) SELECTION OF NOMINAL FIXED SPEED 6 6:21 7 8 6 5 5 4 7 8 6 3 1 SW2 2 3 4 5 6 5 2 2 3 4 1 + 2 3 4 + 9 0 1 9 0 1 SW2 SW1 (1 - OFF) SW2 Code 60 (M1) Code 90 (M2) SW2 Code 60 (M1) Code 90 (M2) 9 53,5 90,2 9 30,9 51,6 8 53,5 90,2 8 28,3 47,2 7 53,5 90,2 7 25,7 42,9 6 51,4 85,8 6 23,1 38,5 5 47,3 81,5 5 20,6 34,4 4 46,3 77,4 4 18 30,2 3 41,1 68,6 3 15,4 25,8 2 38,6 64,4 2 12,9 21,5 1 26 60,0 1 10,3 17,1 0 33,4 55,9 0 7,7 12,8 Connection and characteristic of sensors SN-R and SN-S Model GX-F12A-P (PANASONIC) Supply voltage 12~24 VDC +10-15% Absorbed power P$ Output signal Power max : 100mA Open collector 313QRUPDO\RSHQFRQWDFW12 Brown : 24VDC Blue : 0VDC Black : OUT POP-UP SERIES TECHNICAL DOCUMENTATION 20 Dated 21/07/2016 6. ELEMENTS REPLACEMENT REPLACEMENT OF FREE ROLLER, BELT AND MOTORIZED ROLLER (M1) FOR STRAIGHT CONVEYOR Mounting screws Shaft fixation plate Loosen the screws and remove the plate that holds the axles for the motorized and free rollers in place in order to remove and change elements of the straight conveyor Motorized roller for straight conveyor Ribbed belt ③ Spring shaft Free roller ④ ① ② REPLACEMENT OF WHEEL DIVERTER Wheel ,Q RUGHU WR FKDQJH WKH UROOHU ZKHHO ¿UVW UHPRYH WKH motorized roller and/or free roller. Cover protection Please read the installation and maintenance booklet for full details. Wheel POP-UP SERIES TECHNICAL DOCUMENTATION 1H[WUHPRYHWKHSURWHFWLYHFRYHUWRDFFHVVDQGUHSODFH the worn roller wheel 21 Dated 21/07/2016 REPLACEMENT OF ROUND BELTS FOR DRIVING DIVERTER WHEELS Cables Motorized roller M1 Screw M8 Straight conveyor 7RFKDQJHWKHEHOWV¿UVWUHPRYHWKHXSSHUSDUWRIWKH³SRSXS´ (straight conveyor), then remove the protective cover. 1H[WORRVHQWKHVFUHZDQGPRYHWKHGULYHUROOHUDQGRUIUHHUROOHU to one side in order to change the round belts. Cover protection Please read the installation and maintenance booklet for full details. POP-UP SERIES TECHNICAL DOCUMENTATION 22 Dated 21/07/2016 7. PRODUCT REFERENCES AND ACCESSOIRIES REFERENCES FOR STANDARD POP-UP Size Evacuation left Evacuation right A PUP-45L60P-A-F000 PUP-45R60P-A-F000 B PUP-45L60P-B-F000 PUP-45R60P-B-F000 C PUP-45L60P-C-F000 PUP-45R60P-C-F000 D PUP-45L60P-D-F000 PUP-45R60P-D-F000 PUP – [ 1 ] [ 2 ] [ 3 ] [ 4 ] - [ 5 ] - [ 6] [ 7 ] [ 1 ] DEVIATION ANGLE 45° … 45° (30° … 30° option) [ 2 ] DIRECTION OF EVACUATION L … Evacuation left R … Evacuation right [ 3 ] STRAIGHT CONVEYOR SPEED 60 ... Speed code 60 (60m/min) [ 4 ] PROXIMITY SENSOR LOGIC 1131 3313 [ 5 ] SIZE A … W 394 x L 760 mm B … W 494 x L 760 mm C … W 594 x L 760 mm D … W 694 x L 760 mm Example : PUP-45L60P-B-F00 [ 6 ] TYPE OF MOTORIZED ROLLER F ... PM500FE serie (Angle 45°, evacuation left, Speed code 60m/min, PNP, 494x760mm, motorized roller PM500FE, index 0). [ 7] INDEX VARIANT 0 ... STANDARD 1 ... .... LIST OF ACCESSORIES Optional mounting support Size A Dimension BF A Number of support Reference 400 250 2 PUP-SUP-A B 500 350 2 PUP-SUP-B C 600 450 2 PUP-SUP-C D 700 550 2 PUP-SUP-D POP-UP SERIES TECHNICAL DOCUMENTATION 23 Dated 21/07/2016 24 VDC power supply Reference Input CT-10-241 QT-20-241 380~480V 3 ph QT-40-241 Output Power Start-up boost 24V-10A 240W 120% 24V-20A 480W 150% 24V-40A 960W 150% - Very low inrush current. - Can accomodate over current of 120 to 150% at startup (according to model) Extension cable for motorized rollers (optional) Male side Cable length (mm) Female side Reference 600 ACE-CBM-B0600 1200 ACE-CBM-B1200 60 ±5 37 L Max motor cable length must not exceed 3m (i.e. motor cable + optional extension cable) Wear parts and frequency change Round belt (1) Diverter wheel (4) Motorized roller for straight conveyor Ribbed belt (2) Reference Frequency* MXP5-04/87F L=260mm 5 millions 1 Round belt 2 3 Ribbed belt for straight conveyor 3PJ316 4 Diverter wheel POP-D-ROL 2PJ286 10 millions 5 millions * The frequency of change in number of packages processed is given as an indication. Ribbed belt (3) List of components (excluding wear parts) Motorized roller Size A Size B Size C Size D M1 (straight conveyor) 30)(;3&1 30)(;3&1 30)(;3&1 30)(;3&1 M2 (diverter) 30)&;3'1 30)&;3'1 30)&;3'1 30)&;3'1 M3 (lifting) 30)(;3/1 30)(;3/1 30)(;3/1 30)(;3/1 Free roller )5,';961 )5,';961 )5,';961 )5,';961 Circuit board of motorized rollers PNP logic M1 and M2 CBM-105FP1-EU1 M3 CBR-305FP-B *;)$33$1$621,& Proximity sensor SN-S and SN-R POP-UP SERIES TECHNICAL DOCUMENTATION 24 Dated 21/07/2016 ANNEX 1 DECLARATION OF INCORPORATION in accordance with the EC Machinery Directive 2006/42/EC, Annex II B The manufacturer: ,72+'(1.,&2/WG 1146-2 Asazuma-Cho, Kasai, Hyogo 679-0180 Japan Distributed in Europe by : ,72+'(1.,(XURSH6$6 490 avenue des Jourdies - ZAE les Jourdies - BP 323 74807 St Pierre en Faucigny Cedex - France hereby declares that the product series : POP-UP LVDQLQFRPSOHWHPDFKLQHDVGH¿QHGLQWKH(&0DFKLQHU\'LUHFWLYHDQGWKHUHIRUHGRHVQRWIXOO\PHHW the requirements of this Directive. Commissioning is prohibited until the whole machine/system in which it is incorporated is declared to be in compliance with the EC Machinery Directive The health and safety requirements of Annex I have been applied. The special technical documents in accordance with Annex VII have been drawn up (and, if appropriate, submitted to the competent authorities). Person authorized to compile the technical documentation : ,72+'(1.,&2/WG 7RVKL\XNL7$&+,%$1$ 1146-2 Asazuma-Cho, Kasai, Hyogo 679-0180 Japan EC Directives applied : • Machinery Directive 2006/42/EC • European EMC Directive 2004/108/EC • European RoHS Directive 2011/65/EU 6DLQW3LHUUHHQ)DXFLJQ\1RYHPEHU K. TAMURA, Managing Director POP-UP SERIES TECHNICAL DOCUMENTATION 25 Dated 21/07/2016 ITOH DENKI EUROPE S.A.S. ITOH DENKI GREAT BRITAIN ITOH DENKI GERMANY 490 Av. des Jourdies Z.A.E. les Jourdies 74800 St Pierre en Faucigny - France Tél. : +33 (0)4 50 03 09 99 Fax : +33 (0)4 50 03 07 60 E-mail : [email protected] Suite 1 Trinity Space Centre Waldorf Way :DNH¿HOG:)'+8. Tel : +44 (0)1924 366 539 Fax : +33 (0)4 50 03 07 60 E-mail : [email protected] 1HXPH\HUVWUDEH 1h51%(5*'HXWVFKODQG Tel : +49 911 25 26 - 200 Fax : +49 911 25 26 - 201 E-mail : [email protected] 26 WWW.ITOH-DENKI.COM
Similar documents
tornos y fresas
Weight (net/gross) 44 Kg/54 Kg Packing size(LXWXH) 850 x 340 x 370 mm
More informationKUNST, ANTIEK EN DESIGN 23-06-2016
1 aquarel on paper, signed GAISKA TORREALBA, framed in wooden frame, dim approx 670 x 500 mm, POSITION: C7
More information