LumiLine

Transcription

LumiLine
LumiLine
L140W LumiLine
• Extruded aluminum luminaire with satin anodized finish
• Low profile design with lengths ranging from 20" to 50"
• Proprietary optics are UV stable and optimized for transmission
• Numerous stainless steel and aluminum mounting solutions
• Dimmable, high flux LEDs available in either 3000K or 4000K
Led Specifications
High Output
Standard Output
3000ºK
454 lumens/ft
228 lumens/ft
4000ºK
544 lumens/ft
273 lumens/ft
Power Consumption
10 watts/ft
5 watts/ft
Lumen Maintenance
65,000 hours L70 @ 25ºc
Lumens*
50,000 hours L70 @ 60ºc
Operating Temperature
-30º to 60ºc
Electrical
Input Voltage
Output Voltage
Dimming Control
120V — 277V AC
24V DC
0 — 10V
Certification
Environment
Suitable for wet location. IP65
Listings
UL / cUL / ROHS
* All values are based on initial lumens
www.electrix.com
Custom Submersible LED Luminaire | Client: Lincoln Center | Architect: FX Fowle | Lighting Design: TDA | Photograhy: Iwan Baan
www.electrix.com
3
10
L140W LumiLine
HOW TO SPECIFY
PRODUCT
POWER
LENGTH
LED COLOR
BEAM SPREAD
MOUNT
L140W
05 - 5 W per ft
20"
W3 - 3000K
05 - 5 degree
H - Horizontal
10 - 10 W per ft
30"
W4 - 4000K
60M - 60 degree
lens with
micro
louver
V - Vertical
40"
50"
S - Swivel
60C - 60 degree
clear lens
90F - 90 degree
satine
diffuser
* See www.electrix.com for electronic submittals
with detailed information
DIMENSIONS
CABLES
1 ¼"
(32 mm)
LFC-S32:
1 ⅞"
(48 mm)
11
2"
(50 mm)
www.electrix.com
www.electrix.com
32 ft. primary feed cable
with straight connector.
One required per luminaire.
LFC-A32:
32 ft. primary feed cable
with right angle connector.
12
L140W Photometry
Typical Mounting Detail
Distribution
Illuminance
L140W - 5 degree
90
Center Beam fc
300
1 ft
Color temp:
Fixture length:
Power/lumens:
Power Consumption:
900
3000ºK
4' nominal
39W/1184lm
10W/lin.ft
60
Beam Width
1280
0.1'
358
0.3'
5 ft
95
0.7'
10 ft
26
1.4'
20 ft
8
2.8'
2.5 ft
1500
2100
0
L140W - 60 degree
30
Micro louver
90
Center Beam fc
100
Color temp:
Fixture length:
Power/lumens:
Power Consumption:
3000ºK
4' nominal
39W/932lm
10W/lin.ft
Beam Width
TYPICAL WIRE SCHEMATIC
1 ft
332
0.9'
2.5 ft
108
2.9'
5 ft
28
5.9'
10 ft
8
11.8'
20 ft
3
23.6'
60
300
500
700
0
L140W - 60 degree
30
90
clear
Center Beam fc
175
Color temp:
Fixture length:
Power/lumens:
Power Consumption:
Beam Width
1 ft
354
0.9'
2.5 ft
114
2.9'
5 ft
30
5.9'
10 ft
10
11.8'
20 ft
3
23.6'
60
3000ºK
4' nominal
39W/1275lm
10W/lin.ft
350
If EMI is a consideration, recommended remote driver distance is 15’
Power supplies remotely mount up to 32' from luminaires
525
0
L140W - 90 degree
30
FroST
90
Center Beam fc
175
Color temp:
Fixture length:
Power/lumens:
Power Consumption:
3000ºK
4' nominal
39W/1182lm
10W/lin.ft
60
350
Beam Width
1 ft
1.8'
2.5 ft
4.1'
5 ft
8.3'
10 ft
16.8'
20 ft
33.4'
Typical Wire
Diagram
525
0
Typical Dimming
Diagram 0 - 10V DC
Line Voltage in
32' Feed cable out
32' Feed cable out
120 - 277V AC
to luminaires
to luminaires
0 - 10V Dim control feed
Line voltage in 120 - 277V AC
30
RED (+)
SSL Chromacity Standard - ANSI C78.337
BLUE (-)
3000°K
3000°K White
± 145
WHITE(+)
4000°K White
± 255
Lumen Output Conversions
Color Temperature:
4000°K
Power Consumption
10W/lin.ft
5W/lin.ft
5W/lin.ft
Light Output Multiplier:
1.20
0.61
0.50
4000°K
BLACK (-)
Internal Wiring
Detail
3
13
3
www.electrix.com
www.electrix.com
14

Similar documents