LumiLine
Transcription
LumiLine
LumiLine L140W LumiLine • Extruded aluminum luminaire with satin anodized finish • Low profile design with lengths ranging from 20" to 50" • Proprietary optics are UV stable and optimized for transmission • Numerous stainless steel and aluminum mounting solutions • Dimmable, high flux LEDs available in either 3000K or 4000K Led Specifications High Output Standard Output 3000ºK 454 lumens/ft 228 lumens/ft 4000ºK 544 lumens/ft 273 lumens/ft Power Consumption 10 watts/ft 5 watts/ft Lumen Maintenance 65,000 hours L70 @ 25ºc Lumens* 50,000 hours L70 @ 60ºc Operating Temperature -30º to 60ºc Electrical Input Voltage Output Voltage Dimming Control 120V — 277V AC 24V DC 0 — 10V Certification Environment Suitable for wet location. IP65 Listings UL / cUL / ROHS * All values are based on initial lumens www.electrix.com Custom Submersible LED Luminaire | Client: Lincoln Center | Architect: FX Fowle | Lighting Design: TDA | Photograhy: Iwan Baan www.electrix.com 3 10 L140W LumiLine HOW TO SPECIFY PRODUCT POWER LENGTH LED COLOR BEAM SPREAD MOUNT L140W 05 - 5 W per ft 20" W3 - 3000K 05 - 5 degree H - Horizontal 10 - 10 W per ft 30" W4 - 4000K 60M - 60 degree lens with micro louver V - Vertical 40" 50" S - Swivel 60C - 60 degree clear lens 90F - 90 degree satine diffuser * See www.electrix.com for electronic submittals with detailed information DIMENSIONS CABLES 1 ¼" (32 mm) LFC-S32: 1 ⅞" (48 mm) 11 2" (50 mm) www.electrix.com www.electrix.com 32 ft. primary feed cable with straight connector. One required per luminaire. LFC-A32: 32 ft. primary feed cable with right angle connector. 12 L140W Photometry Typical Mounting Detail Distribution Illuminance L140W - 5 degree 90 Center Beam fc 300 1 ft Color temp: Fixture length: Power/lumens: Power Consumption: 900 3000ºK 4' nominal 39W/1184lm 10W/lin.ft 60 Beam Width 1280 0.1' 358 0.3' 5 ft 95 0.7' 10 ft 26 1.4' 20 ft 8 2.8' 2.5 ft 1500 2100 0 L140W - 60 degree 30 Micro louver 90 Center Beam fc 100 Color temp: Fixture length: Power/lumens: Power Consumption: 3000ºK 4' nominal 39W/932lm 10W/lin.ft Beam Width TYPICAL WIRE SCHEMATIC 1 ft 332 0.9' 2.5 ft 108 2.9' 5 ft 28 5.9' 10 ft 8 11.8' 20 ft 3 23.6' 60 300 500 700 0 L140W - 60 degree 30 90 clear Center Beam fc 175 Color temp: Fixture length: Power/lumens: Power Consumption: Beam Width 1 ft 354 0.9' 2.5 ft 114 2.9' 5 ft 30 5.9' 10 ft 10 11.8' 20 ft 3 23.6' 60 3000ºK 4' nominal 39W/1275lm 10W/lin.ft 350 If EMI is a consideration, recommended remote driver distance is 15’ Power supplies remotely mount up to 32' from luminaires 525 0 L140W - 90 degree 30 FroST 90 Center Beam fc 175 Color temp: Fixture length: Power/lumens: Power Consumption: 3000ºK 4' nominal 39W/1182lm 10W/lin.ft 60 350 Beam Width 1 ft 1.8' 2.5 ft 4.1' 5 ft 8.3' 10 ft 16.8' 20 ft 33.4' Typical Wire Diagram 525 0 Typical Dimming Diagram 0 - 10V DC Line Voltage in 32' Feed cable out 32' Feed cable out 120 - 277V AC to luminaires to luminaires 0 - 10V Dim control feed Line voltage in 120 - 277V AC 30 RED (+) SSL Chromacity Standard - ANSI C78.337 BLUE (-) 3000°K 3000°K White ± 145 WHITE(+) 4000°K White ± 255 Lumen Output Conversions Color Temperature: 4000°K Power Consumption 10W/lin.ft 5W/lin.ft 5W/lin.ft Light Output Multiplier: 1.20 0.61 0.50 4000°K BLACK (-) Internal Wiring Detail 3 13 3 www.electrix.com www.electrix.com 14