934-Resource-Manual-1-up-Revised-10.15
Transcription
934-Resource-Manual-1-up-Revised-10.15
Installation Guide Resource Manual Operating Procedures Parts Breakdown MODEL 934 MOBILE HYDRAULIC COOLING SYSTEMS MODELS AVAILABLE IN BOTH VERSIONS SS/BK934ER SS/BK934EV SS/BK934HR SS/BK934HV SS/BK934E Model #: Serial #: Electric Fan with Relief Valve Electric Fan with Control Valve Hydraulic Fan with Relief Valve Hydraulic Fan with Control Valve Electric Fan with No Valve Installation Date: STAC INC ST PAUL MN 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN MODEL 934 INDEX S TEP DESCRIPTION PAGE Introduction 1 1 Positioning & Mounting 2 2 Installing the PTO & Hyd Pump 2 3 Electrical Wiring 3-4 4 Hydraulic Plumbing 5-6 5 Final Assembly 7 6 Start-Up Procedures 8 System Maintenance 9 Troubleshooting 10 Specifications 11 SS/BK934ER Parts Breakdown 12 SS/BK934EV Parts Breakdown 13 SS/BK934HR Parts Breakdown 14 SS/BK934HV Parts Breakdown 15 SS/BK934E Parts Breakdown 16 Parts List 17 Product Offering 18 Notes 19 Warranty Policy STAC INC ST PAUL MN 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN Please read this guide carefully before installing and operating your MODEL 934 THERMAFLOW system. The THERMAFLOW assembly is designed to cool and filter the oil required to operate your hydraulic system. The oil is cooled by forcing air across cooling fins on the heat exchanger. This system utilizes either an electric or hydraulic fan motor to force air across the fins. The fan motor options and control valve options are described below. The Model 934 has 2 fan motor options, Electric or Hydraulic. The Electric fan motor option has a 12VDC cooling fan which is operated with a temperature control switch. This switch gets wired into keyed power. When the key is turned on, the switch will be ready to activate the fan when the oil temperature gets to 110°F. When the oil temperature falls to 105°F the fan will turn off. The Hydraulic fan motor option has a fixed pressure compensated flow control that automatically cycles the fan “ON” when the hydraulic system is running and “OFF” when not running. This option comes plumbed from the factory. Models 934(E)(H)R comes with a standard relief valve system. While Models 934(E) (H)V have the optional control valve system installed. This control valve system will allow the operator to start, stop, and change rotation of the product pump by simply shifting the control valve. This control valve is integrally mounted and plumbed within the cabinet to save frame rail space, lower installation times, and to reduce hose and fitting costs. Because different product pump applications require different speed and power requirements, your THERMAFLOW system was custom engineered for a particular application. If the system is operated beyond its designed capacity, overheating and/or component damage may result. STAC INC ST PAUL MN PAGE 1 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN STEP 1 POSITIONING & MOUNTING The Model 934 is designed to mount on the frame rail, either on the driver or passenger sides. A) Follow Diagram A for proper mounting and shock mount assembly. NOTE: You will need a minimum of 6 1/2" clearance to remove the filter when mounting under the bunk. ALL MOUNTING ARE SUPPLIED NOTE: FASTENERS IN THE MOUNTING KIT. 1/2-13 GRADE 8 NYLOC NUT (QTY:4) PART #: 600550 1/2-13 GRADE 8 BOLT (QTY:4) RUBBER SHOCK MOUNT (300200 QTY:4) MINIMUM HEIGHT REQUIREDBETWEEN TOP OF FILTER AND BUNK TO REMOVE THE FILTER ELEMENT IS 6-1/2 INCHES 1/2 GRADE 8 WASHER (QTY:8) FRAME RAIL TOP VIEW SPACER (934032 QTY:4) DIAGRAM A STEP 2 INSTALLING THE PTO & HYDRAULIC PUMP A) Install the PTO to the transmission and mount the hydraulic pump according to the instructions included with the PTO. HELPFUL HINT: If you are using a direct mount hydraulic pump/PTO combination, be sure that the pump splines are well lubrication with a heavy grease. This grease will prevent premature spline wear on the PTO and pump shafts. Also available from both MUNCIE and CHELSEA is a new option for a greaseable shaft. This option allows you to grease these splines without pulling the pump off the PTO. STAC INC ST PAUL MN PAGE 2 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN STEP 3 ELECTRICAL WIRING (Models with Electric Fan) Models having a 12 VDC fan motor can be wired two different ways. Listed below are these options. OPTION #1 - FAN SWITCH WIRED HOT This option wires the temp switch so that when the key is turned on it has power going to it. ELECTRICAL CONNECTIONS 10 Gauge RED WIRE: Connect to the positive (+) 12VDC battery terminal (20 Amps) through circuit breaker (150153) provided in electrical kit (934525TC). 10 Gauge BLACK WIRE: Connect to the truck frame or to the negative (-) battery terminal. 18 Gauge RED WIRE: Connect to a keyed power source. For further illustration follow DIAGRAM B on Page 4. NOTE: We recommend that the power supply be taken directly from a battery post or similar high current location. OPTION #2 - TEMP SWITCH WIRED THROUGH AN AIR SWITCH This option wires the temp switch so that you will only be able to run the fan when the PTO is engaged. PTO disengaged fan “OFF”, PTO engaged fan “ON” via an air switch. ELECTRICAL CONNECTIONS 10 Gauge RED WIRE: Connect to the positive (+) 12VDC battery terminal (20 Amps) through circuit breaker (150153) provided in electrical kit (934525TC). 10 Gauge BLACK WIRE: Connect to truck frame or to negative (-) battery terminal. 18 Gauge RED WIRE: Connect to air switch and to positive (+) 12VDC battery terminal with recommended 5 amp fuse. For further illustration follow DIAGRAM C on Page 4. NOTE: We recommend that the power supply be taken directly from a battery post or similar high current location. STAC INC ST PAUL MN PAGE 3 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN STEP 3 ELECTRICAL WIRING (CONTINUED) Diagram B & C below illustrates proper electrical wiring for Models 934ER, 934EV, & 934E. BATTERY CIRCUIT BREAKER 10 GAUGE RED WIRE 18 GAUGE RED WIRE 10 GAUGE BLACK WIRE FRAME GROUND KEYED POWER DIAGRAM B Above electrical schematic illustrates the proper wiring diagram for Option 1. TO PTO AIR LINES TO PTO SWITCH AIR SWITCH 18 GAUGE RED WIRE 5 AMP FUSE (RECOMENDED) 10 GAUGE BLACK WIRE 10 GAUGE RED WIRE CIRCUIT BREAKER FRAME GROUND BATTERY DIAGRAM C Above electrical schematic illustrates the proper wiring diagram for Option 2. STAC INC ST PAUL MN PAGE 4 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN STEP 4 HYDRAULIC PLUMBING DIAGRAMS D & E show proper plumbing for Models 934ER, 934EV, 934HR & 934HV. Please carefully read the Helpful Hints and Notes listed below before beginning. HELPFUL HINT: We recommend the use of 1 1/2” suction hose for all applications, especially if the THERMAFLOW Assembly will be operated in cold weather. If the suction hose is too small the hydraulic pump will cavitate and fail prematurely. 3/4” pressure hose recommended for flows up to 25 gpm. 1” pressure hose recommended for flows greater than 25 gpm. NOTE: Be careful not to over tighten NPT threads. It is very easy to crack these types of ports when tightening fittings. PRESSURE LINE FROM PUMP MAY BE CONNECTED TO EITHER FITTING PRESSURE INLET LINE PRESSURE LINE HYDRAULIC PUMP PTO RETURN FROM SYSTEM PRESSURE TO SYSTEM DIAGRAM D Hydraulic plumbing diagram for THERMAFLOW MODEL 934ER & 934HR STAC INC ST PAUL MN PAGE 5 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN STEP 4 HYDRAULIC PLUMBING (Continued) PRESSURE OUT/RETURN IN PRESSURE IN PRESSURE OUT/RETURN IN INLET LINE PRESSURE LINE HYDRAULIC PUMP PRESSURE OUT/RETURN IN PRESSURE OUT/RETURN IN DIAGRAM E Hydraulic plumbing diagram for THERMAFLOW MODEL 934EV & 934HV STAC INC ST PAUL MN PAGE 6 800-334-7699 PTO INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN STEP 5 Final Assembly A) Complete all hydraulic plumbing. B) Fill the reservoir until the oil level gets to the top black line on the site level gage. NOTE: After the initial start up procedure you will need to add oil due to the hydraulic lines filling up to capacity. NOTE: Over-filling the reservoir will cause the oil to expand up through the breather assembly when the oil warms up. NOTE: We recommend using a high grade of hydraulic oil with a Pour Point of -50 F. This will ensure proper oil flow during extreme cold weather operation. Use of synthetic hydraulic oils is also recommended. Recommended Oil: MOBIL DTE10-32 or equivalent. 1 5 3 ITEM NO. PART NUMBER DESCRIPTION 1 300330ORC COVER O-RING 2 300330OREC CANISTER O-RING 3 300330ORE ELEMENT O-RING 4 300330ORH FILTER HEAD O-RING 5 300331 300330 ELEMENT 300330 FILTER ASSEMBLY WHEN ORDERING A NEW ELEMENT, PART NUMBER 300331 IT INCLUDES A NEW SPRING AND ONE 300330ORE 2 DIAGRAM F 4 STAC INC Filter assembly procedures for all Model 934 Thermaflow's. ST PAUL MN PAGE 7 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN STEP 6 START-UP PROCEDURES The following steps are to ensure that the THERMAFLOW assembly is operating properly. NOTE: Before engaging the PTO, make sure that all hydraulic lines are plumbed and properly tightened. 1) Slowly engage the PTO with engine at idle speed. NOTE: Watch the oil level in the reservoir. Be ready to add more oil as needed to maintain the oil level between the black and red lines on the site level gage. 2) Check for hydraulic leaks and fix as needed. 3) Check for fan operation (Electric & Hydraulic). 4) Carefully Tach the product pump speed. 5) Slowly increase the engine speed until desired product pump speed is obtained. 6) Run system for at least five minutes to ensure that system is sufficiently cooling the hydraulic oil. If you have a Hydraulic Flow Meter Kit set required pressure and flow rates as needed. 7) Slow engine to idle and disengage the PTO. 8) System is ready for operation. STAC INC ST PAUL MN PAGE 8 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN System Maintenance Hydraulic Fluid: Drain and replace hydraulic oil every 6 to 12 months depending on use. Recommended Fluid: MOBIL DTE10-32 or equivalent. Filter: Remove 4 cap screws (10mm) on top of filter housing. Remove filter cartridge and spring. Replace with new filter cartridge and spring Part Number 300331 Apply anti-seize to cap screws and tighten. Pump: Inspect periodically for leaks. Check hoses for signs of wear. Motor: Inspect periodically for leaks. Check hoses for signs of wear. PTO: Grease output shaft every 6 to 12 months depending on use. If PTO does not have a grease zerk on output shaft, remove direct mount hydraulic pump and grease the output shaft using a high quality gear lube. STAC INC ST PAUL MN PAGE 9 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN Troubleshooting Safety First! Think about it before you do it. Our systems use controlled fluid pressure and converts it to rotational movement. This means that the system pressure operates around 2000 psi. A pin hole leak of fluid at this pressure can be dangerous. Use caution when loosening fittings, system pressure can be maintained for a period of time after shutdown. Troubleshooting Always inspect the things easiest to eliminate first. Look for faulty linkage or wiring that controls the PTO,pump or motor. Look at the fluid level and appearance of the oil. Check temperatures and pressures. Excessive Heat: Clean air passages through heat exchanger Check fan operation Check setting of relief valve Check temperature of suction line vs outlet line temperature. If the outlet temperature is noticeably hotter, the pump is cavitating. Check for contamination in relief valve. Clean and replace. Check for added flow controls. If a flow control has been added to the system, excess heat can be generated by the added restriction to flow Loss of Motor Speed: Check oil level. Ensure recommended engine idle speed is maintained. Check output pressure of the pump. If system pressure cannot be maintained, attempt to adjust the relief valve setting to max system pressure. If this does not make a noticeable change, make sure to return relief setting to original position and bring the pump and motor to a hydraulic specialist for bench testing and possible replacement. Excessive Noise: Check oil level. Fill to proper level Ensure use of recommended oil type and weight Ensure suction line to pump is at least 1 1/2” Ensure there is no restriction in suction line. Oil Discoloration: Ensure suction line connections are tight. Ensure oil is free from water and contaminants. Drain and refill with recommended oil and replace filter. Ensure use of recommended oil type and weight STAC INC ST PAUL MN PAGE 10 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN Specifications Max Flow Rate: Max Pressure Reservoir: Weight Suction Line Pressure Lines Warranty 30 gpm 3000/5000 psi 3.5 gal 79 lbs 1.5 Inch 3/4 Inch 2 years Oil - The recommended oil is MOBIL DTE10-32 or equivalent. Mobil DTE 10-32 is a supreme performance anti-wear hydraulic oil engineered for wide temperature range applications. It exhibits optimum flow characteristics at sub-zero temperatures and is resistant to shearing and viscosity loss so that system efficiency is maintained and internal pump leakage is minimized at high operating temperatures and pressures. STAC INC ST PAUL MN PAGE 11 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN MODEL SS934ER/BK934ER 9 ITEM N 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 9 1 16 ? 16 19 7 7 19 5 5 8 8 13 13 2 2 14 15 11 10 15 11 10 3 3 17 12 18 12 6 18 21 20 21 STAC INC ST PAUL MN PAGE 12 22 21 6 21 22 21 21 800-334-7699 20 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN MODEL SS934EV/BK934EV 9 ITEM NO 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 21 22 23 24 25 9 1 16 1 16 7 19 57 19 5 8 13 13 2 14 2 15 11 8 14 15 11 10 3 10 3 17 12 18 12 4 21 21 21 STAC INC ST PAUL MN PAGE 13 18 4 22 22 23 21 21 17 25 24 21 800-334-7699 23 25 24 16 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN MODEL SS934HR/BK934HR 17 1 7 1 9 5 34 2 11 16 19 29 17 29 7 9 11 6 2 19 28 5 30 ITEM NO. 1 2 3 5 6 7 309 11 12 13 14 15 16 17 19 20 21 22 26 27 28 29 30 38 31 32 33 34 35 22 26 6 28 13 3 15 32 33 41 30 12 22 26 13 3 27 21 35 14 15 20 32 33 21 30 31 21 35 12 27 20 21 31 STAC INC ST PAUL MN PAGE 14 800-334-7699 PART NUMBER DESCRIP BLK = 934 BLACK M 300330 FILTER ASS 34 300334 SITE GL 300410 8MORB 300416 16MJIC-16M 300730 12MJIC-12MOR ITEM NO. PAR 375418 16MJIC-16MOR 600332 BREAT 1 934000/934000BLK 934 TA 2 934 LEFT 934010/934010BLK 934020/934020BLK 3 934 RIGH 934030/934030BLK 934 CO 5 934040 6934 VALVE 934050/904050BLK 934 7 SUPPORT 934300 934 9 HEAT EXC 934728 934 TU 11 93400 300702 3000 PSI REL 12 93401 300708 12MJIC-12M 13 93402 934714 12MORB-12FJ 14 93403 150510 HYD FAN M 15 150904 6MJIC-12FJIC 16 93405 150908 8MORB-8MORB 17 150912 6MJIC-8MOR 196MJIC-8M 600732 20 600734 12MJIC-12MJIC 21 FLOW CO 600830 22HYD FAN M 934850 26FAN RETUR 934892 27 FAN INLE 934894 14 28 29 30 31 32 33 34 35 38 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN MODEL SS934HV/BK934HV 1 17 29 1 16 7 5 19 9 29 11 16 9 17 7 2 19 13 5 36 4 11 30 2 13 22 26 33 36 4 30 22 32 15 36 30 3 26 28 33 37 27 32 21 28 23 15 3 30 25 12 21 21 36 21 14 37 38 24 23 14 25 12 21 21 STAC INC ST PAUL MN PAGE 15 24 800-334-7699 ITEM NO. 1 2 3 4 5 7 9 11 12 13 14 15 16 17 19 21 22 23 300330 300334 300410 300412 300416 375418 600332 934000/934000BLK 934010/934010BLK 934020/934020BLK 934030/934303BLK 934040 934050/934050BLK 934300 934728 300708 934714 934070 24 934708 26 150510 25 934722 28 29 30 32 33 34 36 37 150908 150912 600732 600830 934850 934892 934890 934720 BLK = PART NUMBER 1 1 8M INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN MODEL SS934E ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 9 19 16 1 16 7 19 7 5 19 5 8 8 13 13 2 2 14 15 11 15 10 11 3 14 10 3 17 12 12 18 18 6 STAC INC ST PAUL MN PAGE 16 17 4 6 800-334-7699 4 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN Parts List Item Part Number Description Item Part Number Description 1 300330 600/934 FILTER ASSEMBLY 21 300708 12MJIC-12MORB 90° 2 300334 SITE GLASS 22 934714 12MORB-FJIC SWIVEL 3 300410 8MORB PLUG 23 934070 934722 VALVE HANDLE 4 300412 12MORB PLUG 24 934708 12MJIC-12MORB 90° LONG NECK 5 300416 16MJIC-16MORB 90° 25 934722 DIRECTIONAL CONTROL VALVE 6 300730 12MJIC-12MORB STRAIGHT 26 150510 HYD FAN MOTOR 7 375418 16MJIC-16MORB STRAIGHT 27 150904 6MJIC-12FJIC REDUCER 8 600306 11” FAN 28 150908 8MORB-8MORB ADJUSTABLE 9 600332 BREATHER 29 150912 6MJIC-8MORB STRAIGHT 10 800515 TEMP SWITCH 30 600732 6MJIC-8MORB STRAIGHT 11 934000/934000BLK 934 TANK 31 600734 12MJIC-12MJIC-12MORB TEE 12 934010/934010BLK 934 LEFT SIDE 32 600830 FLOW CONTROL 13 934020/934020BLK 934 RIGHT SIDE 33 934850 HYD FAN MOTOR MOUNT 14 934030/934030BLK 934 COVER 34 934892 FAN RETURN HOSE 15 934040 934 VALVE BRACKET 35 934894 FAN INLET HOSE 16 934050/934050BLK 934 SUPPORT BRACKET 36 934890 FAN INLET HOSE 17 934300 934 HEAT EXCHANGER 37 934720 6MJIC-6ORB STRAIGHT 18 934535 934 ELECTRICAL HARNESS 38 600820 HYDRAULIC FAN BLADE 19 934728 934 TUBE BLK = 934 BLACK MODEL PART 20 300702 3000 PSI RELIEF VALVE STAC INC ST PAUL MN PAGE 17 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN Product Offering Fans Spal Multi-Wing Fittings Tompkins Stucci Ryco Heat Exchangers Thermal Transfer Flat Plate AKG Hydraulic Motors Eaton/Charlynn Muncie Permco Hydro Leduc PTO’s Muncie Pumps Muncie Parker Permco Hydro Leduc STAC INC ST PAUL MN PAGE 18 800-334-7699 INSTALLATION GUIDE , OPERATING PROCEDURES & PARTS BREAKDOWN Notes STAC INC ST PAUL MN PAGE 19 800-334-7699 THERMAFLOW WARRANTY The THERMAFLOW 934 Series Hydraulic Cooler is warranted against any defect in material and workmanship which existed at the time of sale by STAC Inc. according to the following provisions, subject to the requirements that the Cooler must be used only in accordance with the catalogue and package instructions. The Cooler is warranted for a period of TWO Years from the date of installation. If during the warranty period the cooler fails to operate to STAC’s specifications due to a defect in any part in material or workmanship that existed at the time of sale by STAC Inc., the defective part will be repaired or replaced, at STAC Inc.’s discretion, at no charge, if the defective part is returned to STAC Inc. with transportation prepaid. The above warranty shall terminate if any alterations or repairs are made to the System other than at an authorized dealer or if the cooler is used on any equipment other than the equipment upon which it is first installed. THE FORGOING WARRANTIES ARE IN LIEU OF ALL OTHER OBLIGATIONS AND LIABILITIES, INCLUDING NEGLIGENCE AND ALL WARRANTIES OF MERCHANTABILITY AND SUITABILITY, EXPRESSED OR IMPLIED AND STATE STAC INC.’S ENTIRE AND EXCLUSIVE LIABILITY AND BUYER’S EXCLUSIVE REMEDY FOR ANY CLAIM OF DAMAGES IN CONNECTION WITH THE SALE, REPAIR OR REPLACEMENT OF THE ABOVE GOODS, THEIR DESIGN, INSTALLATION OR OPERATION. STAC INC. WILL IN NO EVENT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES WHATSOEVER, AND OUR LIABILITY UNDER NO CIRCUMSTANCES WILL EXCEED THE CONTRACT PRICE FOR THE GOODS FOR WHICH LIABILITY IS CLAIMED. Inc. 60 West Sycamore Street, St. Paul MN 55117 800-334-7699 • 763-235-7822 Fax Web: www.thermaflow.com Thermaflow is a registered trademark of STAC, Inc. All Rights Reserved. Form 934901 Rev: 10/2015