Shed Creek Winery Wastewater Plans
Transcription
Shed Creek Winery Wastewater Plans
WASTEWATER PLAN N FOR THE SHED CREEK WINERY N 80 GRAPEVINE LANE NAPA, CA 94558 APN: 033-170-002 ANGWIN CALISTOGA BERRYESSA HIGHLANDS DATE: 5/14/2015 SAINT HELENA NAPA PROJECT LOCATION (E) BARN AMERICAN CANYON PREPARED BY: (E) ACCESSORY BUILDINGS PROJECT #: 00066 CIRCLE OAKS YOUNTVILLE CAMERON PRIDMORE PE, PLS 1607 CAPELL VALLEY ROAD NAPA, CA 94558 (707) 815-0988 RUTHERFORD VICINITY MAP SHED CREEK WINERY 80 GRAPEVINE LANE NAPA, CA 94558 APN: 033-170-002 NTS (E) APPROXIMATE PROPERTY LINE (E) LEACH FIELD, APPROXIMATE LOCATION (E) SEPTIC TANK SHEET INDEX (E) DRIVEWAY (E) LEACH FIELD, APPROXIMATE LOCATION (E) SEPTIC TANK (E) BARN TO BE CONVERTED TO WINERY (E) TEST PIT 1 (P) DOMESTIC AND SEPARATE PROCESS WASTEWATER SYSTEM MEETING CENTRAL VALLEY WQCB REQ. (P) PROCESS SPRINKLER FIELD (P) 200% RESERVE AREA SHT. # DESCRIPTION 1 TITLE SHEET 2 DOMESTIC WASTEWATER PLAN 3 PROCESS WASTEWATER PLAN 4 DOMESTIC SYSTEM NOTES & DETAIL 5 PROCESS SYSTEM NOTES & DETAIL TITLE SHEET (E) RESIDENCE OWNER: (E) 2ND DWELLING (E) TEST PIT 2 UNAUTHORIZED CHANGES & USES: (P) LEACH FIELD (E) TEST PIT 3 (E) ACCESS DRIVEWAY TO GORDON VALLEY ROAD SITE MAP . 12-31-2016 75 150 SCALE: 1"=150' R# DESCRIPTION DATE 1 7-7-15 NC COM. 11-2-15 2 1-7-16 NC COM. 5-26-16 PROPERTY LINES: 1" = 150' 0 THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE DESIGNER OF THESE PLANS. 300 THE PROPERTY LINES SHOWN HEREON ARE BASED ON PRELIMINARY SURVEY DATA, AND ARE FOR REFERENCE ONLY. THIS IS NOT A BOUNDARY SURVEY MAP AND SHOULD NOT BE USED AS SUCH. SHEET: 1 OF 5 ESTABLISH GRASS TYPE VEGETATIVE COVER MOUND FOR DRAINAGE EXISTING GROUND SURFACE TOPSOIL 12" NATIVE FILL ADS ARC 24 INFILTRATOR CHAMBER OR APR. EQ TRENCH DETAIL PREPARED BY: NO SCALE DOMESTIC WASTEWATER PLAN OWNER: LID WITH OBSERVATION PORT AND 4" RISER TUF-TITE 4 HOLE DISTRIBUTION BOX MODEL: 4HD2 LID WITH OBSERVATION PORT 3 S-40 PIPE FITTINGS. FITS SCH. 40 4" PIPE. NO GROUT REQUIRED. 11" 4" SCH 40 SOLID PVC PIPE A A 11" 15 1/2" 2" 6" MIN' CONCRETE BED TOP VIEW SECTION A-A FOR COMPLETE DESIGN AND INSTALLATION DETAILS, CONTACT TUF-TITE DISTRIBUTION BOX DETAIL NO SCALE PROJECT #: 00066 24" CAMERON PRIDMORE PE, PLS 1607 CAPELL VALLEY ROAD NAPA, CA 94558 (707) 815-0988 TRENCH BOTTOM EXCAVATED ALONG LEVEL CONTOUR SHED CREEK WINERY 80 GRAPEVINE LANE NAPA, CA 94558 APN: 033-170-002 INSTALL 140N MIRIFI FILTER FABRIC OR APR. EQ. OVER TOP OF CHAMBER DATE: 5/14/2015 12" TRENCH TUF-TITE SPEED LEVELER (TYP) ADJUST TO EQUALIZE DISTRIBUTION BOX FLOW 0 20 40 SCALE: 1"=40' 60 80 NOTES: 1. ACTUAL TANK LOCATION MAY VARY IN THE FIELD DUE TO TANK SETTING ACCESSIBILITY. IF TANK LOCATION MUST DIFFER FROM PLAN MAINTAIN MIN 2% PIPE FALL TO AND FROM TANK AND CONFIRM NEW LOCATION MEETS ALL NAPA COUNTY CODES & SETBACK REQUIREMENTS. 2. TIME DOSE DIGITAL CONTROL PANEL MUST BE INSTALLED WITHIN 25' FROM HOUSE UNLESS A REMOTE ALARM IS INSTALLED R# DESCRIPTION DATE 1 7-7-15 NC COM. 11-2-15 2 1-7-16 NC COM. 5-26-16 SHEET: 2 OF 5 DATE: 5/14/2015 PROJECT #: 00066 CAMERON PRIDMORE PE, PLS 1607 CAPELL VALLEY ROAD NAPA, CA 94558 (707) 815-0988 SHED CREEK WINERY 80 GRAPEVINE LANE NAPA, CA 94558 APN: 033-170-002 PREPARED BY: OWNER: PROCESS WASTEWATER PLAN (P) 1.5" SCH 40 PVC 0 20 40 SCALE: 1"=40' 60 80 NOTES: 1. ACTUAL TANK LOCATION MAY VARY IN THE FIELD DUE TO TANK SETTING ACCESSIBILITY. IF TANK LOCATION MUST DIFFER FROM PLAN MAINTAIN MIN 2% PIPE FALL TO AND FROM TANK AND CONFIRM NEW LOCATION MEETS ALL NAPA COUNTY CODES & SETBACK REQUIREMENTS. 2. TIME DOSE DIGITAL CONTROL PANEL MUST BE INSTALLED WITHIN 25' FROM BUILDING UNLESS A REMOTE ALARM IS INSTALLED R# DESCRIPTION DATE 1 7-7-15 NC COM. 11-2-15 2 1-7-16 NC COM. 5-26-16 SHEET: 3 OF 5 TIMED DOSE DIGITAL PANEL, INCLUDED WITH ORENCO EASYPAK PUMP PACKAGE MODEL# BEP-10-TDD TO DIGITAL PANEL (SET PUMP ON TIMER FOR 4.5 MIN 10 TIMES PER DAY) SIDE VIEW NORMAL LIQUID LEVEL TIMER ON/OFF 3'-0" 1'-9" 2'-1" SIDE VIEW 1200 GALLON SEPTIC TANK CUTAWAY CUTAWAY HIGH LEVEL ALARM FLOAT / PUMP ON OVERRIDE 1'-6" 1200 GALLON PUMP TANK PUMP OFF FLOAT ORENCO EASYPAK PUMP PACKAGE MODEL # BEP-10-TDD 9'-3" CONDUIT TO PANEL DATE: 5/14/2015 4'-9" 355 GAL RESERVE PROJECT #: 00066 INLET FROM SEPTIC TANK INV. = 5'-8" DETERMINE IN FIELD 4'-3" MAINTAIN 2% MIN FALL FROM SEPTIC TANK PVC SPLICE BOX DISCHARGE ASSEMBLY TO LEACH FIELD WATER TIGHT SEAL CAMERON PRIDMORE PE, PLS 1607 CAPELL VALLEY ROAD NAPA, CA 94558 (707) 815-0988 4" INLET & OUTLET PIPE AND FITTINGS STANDARD (TYP) 24" DIA PVC RISER WITH 24" GASKETED FIBERGLASS LID WITH S.S. BOLTS PREPARED BY: 24" DIA PVC RISER WITH 24" GASKETED FIBERGLASS LID WITH S.S. BOLTS SHED CREEK WINERY 80 GRAPEVINE LANE NAPA, CA 94558 APN: 033-170-002 EASY PACK PUMP 5'-2" LIQUID CAPACITY: 1200 GALLONS BOX DESIGN LOAD: NON-TRAFFIC, UP TO 3 FEET OF SOIL COVER, MAXIMUM 500 PSF. TOP VIEW NOTE: FOR COMPLETE DESIGN AND PRODUCT INFORMATION CONTACT SELVAGE CONCRETE PRODUCTS INC. AND ORENCO SYSTEMS INC. DOMESTIC SYSTEM NOTES & DETAILS TOP VIEW OWNER: TO LEACH FIELD SEPTIC TANK AND PUMP TANK DETAIL SELVAGE SEPTIC/ PUMP TANK, NO SCALE END TOP END CAPS SIDE ADS ARC 24 CHAMBER DETAIL NO SCALE PRIMARY WASTEWATER CALCULATIONS 1. SOIL TYPE IS CLAY LOAM WITH MODERATE GRANULAR STRUCTURE 2. BASED ON SOIL TYPE THE INFILTRATION RATE = 0.25 GAL/SF/DAY 3. USING INFILTRATOR CHAMBERS, THE NET ABSORPTION AREA PER LINEAR FOOT OF TRENCH = 3 SF/LF 3. THE WINERIES EXPECTED PROCESS WASTE IS 250 GALLONS PER DAY, WHICH WILL BE PROCESS VIA THE PROPOSED 2000 GALLON HOLD AN HAUL TANK SYSTEM. THE REQUIRED STORAGE IS 7 X 250 GAL = 1750 G. 4. THE WINERIES EXPECTED SANITARY WASTE IS 105 GALLONS PER DAY 5. THE TOTAL EXPECTED GALLONS PER DAY TO THE WINERY LEACHFIELD IS = 105 GAL/DAY 6. THE MINIMUM TOTAL LENGTH OF TRENCH REQUIRED TO TREAT THE EXPECTED EFFLUENT IS 105 GAL/DAY / [(0.25 GAL/SF/DAY) X (3 SF/LF)] = 140 LF RESERVE WASTEWATER CALCULATIONS 1. SOIL TYPE IN THE TRENCH ZONE IS CLAY LOAM WITH MODERATE GRANULAR STRUCTURE 2. BASED ON SOIL TYPE THE INFILTRATION RATE FOR DRIP = 0.6 GAL/SF/DAY 3. THE WINERIES EXPECTED PROCESS WASTE IS 250 GALLONS PER DAY 4. THE WINERIES EXPECTED SANITARY WASTE IS 105 GALLONS PER DAY 5. THE TOTAL EXPECTED GALLONS PER DAY FROM THE PROPOSED WINERY = 355 GAL/DAY 6. THE MINIMUM DISPERSION FIELD AREA FOR AN ENGINEERED DRIP SYSTEM GIVEN THE ABOVE VARIABLES IS (355 GAL/DAY / 0.6 GAL/SF/DAY X 200%) = 1183 SF R# DESCRIPTION DATE 1 7-7-15 NC COM. 11-2-15 2 1-7-16 NC COM. 5-26-16 SHEET: 4 OF 5 FILTER FLUSH RETURN LINE HOLDING TANK TOP VIEW NTS BIOTUBE & PUMP NTS TO FIELD 24" DIA PVC RISER WITH 24" GASKETED FIBERGLASS LID WITH S.S. BOLTS (TYP) ORENCO INTERNAL SPLICE BOX OUND SLOPE GR M RISER O R AWAY F YP) 2% MIN (T YP) 2% MIN (T PUMP BASIN TOP VIEW NTS 24" DIA PVC RISER WITH 24" GASKETED FIBERGLASS LID WITH S.S. BOLTS (TYP) FILTER ALARM CONDUIT TO PANEL PREPARED BY: 24" DIA PVC RISER WITH 24" GASKETED FIBERGLASS LID WITH S.S. BOLTS (TYP) PVC SPLICE BOX SHED CREEK WINERY 80 GRAPEVINE LANE NAPA, CA 94558 APN: 033-170-002 SEPTIC TANK TOP VIEW 1.5" RETURN LINE FROM FILTER FLUSH TO CONTROL PANEL DISCHARGE ASSEMBLY TO FIELD 1500 GALLON RESERVE HIGH LEVEL ALARM FLOAT SELVAGE 2000 GAL CONCRETE HOLDING TANKS FLOW-THROUGH PORT OWNER: INLET TEE STANDARD SEPTIC FITTING (TYP) SELVAGE 2000 GAL BAFFLED CONCRETE SEPTIC TANK ZABEL A-300 12X20 WITH SMART FILTER ALARM OR EQ . 1.0' 4" FLOW THROUGH CONNECTION FOR MULTIPLE TANKS TIMER ON/OFF OVERRIDE FLOAT REDUNDANT PUMP OFF FLOAT 5.50' 4.00' SEPTIC TANK SECTION VIEW HOLDING TANK SECTION VIEW NTS NTS SEPTIC TANK DETAIL HOLDING TANKS DETAIL FOR SCHEMATICAL PURPOSES, ACTUAL LAYOUT MAY VARY, SEE FOR SCHEMATICAL PURPOSES, ACTUAL LAYOUT MAY VARY, SEE PLAN (N.T.S.) PLAN (N.T.S.) PROCESS SYSTEM NOTES & DETAILS NORMAL LIQUID LEVEL NORMAL LIQUID LEVEL PROJECT #: 00066 CONDUIT TO PANEL CAMERON PRIDMORE PE, PLS 1607 CAPELL VALLEY ROAD NAPA, CA 94558 (707) 815-0988 4" PVC DISCHARGE LINE SLOPE MIN 2% DATE: 5/14/2015 INLET 6" 3.50' 3.00' HOLDING TANKS 4" MIN PVC PIPE FROM TANK BIOTUBE PUMP VAULT MODEL # PVU68-2425 WITH PUMP MODEL # PF203034 CUSTOM ORENCO PUMP BASIN MODEL TO FIT HEIGHT REQ. R# DESCRIPTION DATE PUMP BASIN SECTION VIEW 1 7-7-15 NC COM. 11-2-15 NTS 2 1-7-16 NC COM. 5-26-16 PUMP BASIN DETAIL FOR SCHEMATICAL PURPOSES, ACTUAL LAYOUT MAY VARY, SEE PLAN (N.T.S.) SHEET: 5 OF 5