TROX - The art of handling air
Transcription
TROX - The art of handling air
The art of handling air …… The art of handling air …… Good air is a factor in your quality of life. Whether outside in the open air or in an enclosed space, we only feel truly well in the fresh air. Air, the elixir of life, lets us breathe freely. It is invigorating, inspiring, and gives us the energy to live and work. TROX understands the art of competently handling air like no other company. In close collaboration with demanding customers from around the globe, we have successfully manufactured leading technologies and marketed systems and components for indoor ventilation and air conditioning. We are consistently expanding upon this position by means of intensive research and development activities. Heinz Trox The individual is the focus at TROX: as a customer with visionary ideas and technological goals: as a motivated and qualified company employee, as a responsible decision-maker at the management level and, last but not least, as a human being who would like to live and work in well-ventilated spaces. Since our corporation was founded, we have stood by this philosophy and vouched for our good name. Indicative of our solution-minded approach, it has created our distinctive customer base and thus become the source of our company’s success. Headquarters Neukirchen-Vluyn, Germany On the following pages, we would like to introduce TROX and its extensive product range. Please, take us at our word by challenging us with ambitious tasks and placing trust in our competency and customer oriented thinking! Share the experience: The art of handling air! Heinz Trox 1 … The individual is the deciding factor …… The individual remains the deciding factor in all that TROX undertakes. The individual, by virtue of his or her visions, wishes, needs, abilities, and knowlege, defines the goals that TROX pursues carefully and deliberately. TROX is an owner-led company with horizontal hierarchies in which the individual has decisionmaking powers. Consistency, reliability, and a mature feeling of responsibility for customers, employees and the environment have been the pillars of the TROX GROUP company politics for decades. It is the customers of TROX that decide how the company will act on their behalf. They set goals based upon their well-being as well as their architectural and technological visions, and TROX in turn assists them in realising those goals. The customer-oriented corporate leadership has made TROX what it is today: a world-wide and effective partner for those demanding ventilation and air conditioning solutions for all types of buildings. Each and every employee contributes to the success of the company in that they earn the customers’ trust with their motivation and competence, and then they confirm that trust day after day. The targeted training and continued education of our employees, as well as their lasting job satisfaction, are thus important concerns of TROX management. …… 2 … In a small space of 110 square metres at his living quarters in Neukirchen-Vluyn, Heinrich Trox began the production of diffusers together with his brother Friedrich in 1951. Within a few years, this garage start-up became a successful medium-sized company, which is still family-owned today. Heinrich Trox, company founder TROX, 1951, Neukirchen-Vluyn, Germany TROX in figures …3,000 employees worldwide …EUR 380 million turnover in 2008 …24 subsidiaries in 22 countries …14 production plants in 12 countries …12 research and development centres worldwide …More than 25 additional sales offices and more than 50 representatives and importers across the globe TROX history …1951 The company was founded by Heinrich Trox in Neukirchen-Vluyn. …1960 Klaus and Heinz Trox joined the company. …1962 The international focus of the company began with the establishment of a subsidiary in UK. …1970 The first overseas subsidiary was founded in South Africa. TROX now has more than 1,000 employees. …1994 TROX Malaysia was founded. …2001 Heinz Trox changed from the Board of Management to the Supervisory Board. TROX China was founded. …2005 Takeover of the Auranor Group in Norway and Sweden and founding of the subsidiary in Russia …2006 Heinz Trox became the sole owner. The company name was changed from Gebrüder Trox GmbH to TROX GmbH. TROX AITCS was founded in UK. …2007 TROX implemented the participation programme for executives. TROX Middle East (Dubai), TROX India (Mumbai) and TROX Argentina (Buenos Aires) were founded. …2008 Disincorporation of TROX Deutschland GmbH; start of production in the United States …2009 Establishment of the International Center Fire Protection International Center Fire Protection, Neukirchen-Vluyn, Germany 3 … A tradition of innovation …… The history of the company began with an innovation: the specialisation in components for ventilation technology. In the air conditioning industry, which was still quite young in 1951, this was a revolutionary decision. Trailblazing inventions have since marked the rise of the company to the leading position in marketing and technology. Innovations themselves are tradition with TROX. The company holds over 200 patents and registered designs in ventilation and air conditioning technology. The systematic research and development of the individual product groups enjoys increasing expansion based on project-related development contracts. With its customer-specific solutions, TROX sets an innovating standard and, with that in mind, continues to enter new and lucrative markets and maintain sustainable business opportunities. As a result, TROX, since the introduction of the first ceiling induction diffusers in the 1980s, has been the leading supplier of these multifaceted products in Europe. Cyclone, ISH Trade Fair 2007 4 … Mock-up test for Rio Santos Dumont Airport Selected pioneering feats 1968: 1969: 1974: 1975: 1981: 1988: 1993: 1994: 1995: 2000: 2004: 2005: 2006: 2007: 2008: Development of the Type FD swirl diffuser for mixed flow application Registered design protection for the installation of grilles in ventilation ducting Construction of the first fire damper with an official mark of conformity Development of the Type RN flow rate controller, with which TROX advanced to become the European market leader in the constant flow rate controller sector The first temperature-dependent airstream control unit with electric actuator (DG-VAR) Construction of the first Type DID active chilled beam. Today, TROX leads Europe in the supply of these innovative chilled beams. Innovative new design of the system-powered Type RN air terminal unit with external flow rate scale First refurbishment damper Type E01-K90 Development of the first multi-service chilled beam Development of the decentralised ventilation systems for large construction projects for office and administrative buildings Development of the Type TVR-Easy air terminal unit for variable volume flow rates Introduction of AITCS (Advanced IT Cooling Systems), CO2-based system solutions for the IT sector First-time use of phase change materials (PCM) in decentralised ventilation units Development of the Type VFC orientationindependent, system-powered air terminal unit for low air velocities Introduction of a fire damper compliant with European standards Recipient of the Rietschel-Diplom Excellence Award for TROX Spain TROX is winner of „Austrian Leading Companies“ Selected prizes and awards 1984/ Gold medal for the first temperature-dependent, 1985: automatically-operated air discharge control unit without auxiliary power (DG-SELF) at Interclima in Paris, France 1999: Silver medal for outstanding design of the “Wavestream” at Interclima in Paris, France 2002: Gold medal for outstanding design of the “Passclean” at ExpoComfort in Milan, Italy 2005: The “Architecture and Technology” Innovation Prize in Frankfurt, Germany, for the “Zyklon”, an extremely flat façade ventilation unit 2007: 2008: 2009: Awarding of the Rietschel-Diplom to Heinz Trox; TROX Spain wins the Excellence Award Eight international prizes for CO2-based IT system cooling solutions for TROX AITCS; TROX Austria: winner of the Vienna “Austrian Leading Companies” in the category “Golden mid-size enterprises“ The “Architecture and Technology” Innovation Price in Frankfurt, Germany, for façade ventilation units in project-specific installation-situation; Special award “Architecture and Technology” in Frankfurt, Germany, for undersill induction diffusers. 5 … …… Frauenkirche, Dresden, Germany 6 … More than the sum of its parts …… TROX offers products and components for all areas of centralised and decentralised ventilation and air conditioning technology. The comprehensive product range extends from ventilation to fire control and flow rate control technology to acoustics and filters. An ongoing optimisation of the products and production processes ensures lasting improvements to quality. Passclean design ceiling diffuser for rooms with high occupancy As well as the product diversity and the high number of standard product variations, the sales engineers at TROX will arrive at an optimum solution for their customers with an individual solution for every request. Whoever chooses to enlist the services of TROX will be getting more than just the sum of its parts because each component is designed for optimum compatibility. You can feel the difference. More comfort in a draft-free and noise-controlled atmosphere that never sacrifices its high air quality – the result is one which effectively increases a building’s value and functionality. Fire damper can be used all over Europe TROX components TROX systems … Air terminal devices … Fire and smoke protection components … Air terminal units … Shut-off devices … Sound attenuators … Filters and filter units … Air-water systems … Decentralised ventilation systems … Laboratory ventilation systems … Communication and automation systems ... Advanced IT Cooling Systems (AITCS) 7 … Exciting solutions …… …… In close collaboration with TROX’s customers, the “Architecture and Indoor Climate“ team develops solutions and supports architects and consultants with the development of optimum indoor ventilation concepts for new buildings and refurbishment projects. Whether it is a matter of ventilation systems for laboratories, the connection of fire dampers to control and communication systems, the development of design-oriented air-water systems, or the integration of decentralised ventilation units into façades: the path that TROX takes with its customers has been proven time and again. The earlier TROX engineers are integrated in the design process, the more resounding the success. The “Architecture and Indoor Climate“ team offers planning security and cost control for complex buildings with detailed planning along the collaborative process shared with owners, architects, consultants, and contractors. The collaborative process “Architecture and Indoor Climate“ … Integration into architectural planning … Concept development and optimisation … Variant analysis … Energy usage evaluations … Economic efficiency analysis … Design development … Building of prototypes … Performance tests (cooling, heating,acoustics, air flow behaviour) … Order execution Decentralised undersill units, Lighttower, Frankfurt/Main, Germany 8 … Your advantages … Shorter construction periods … Reduced ceiling void heights … Easier installation (plug-and-play) … Quicker return on investment … Clear reduction interfaces … Less maintenance and operating costs … Energy savings … More flexible retrofitting … Intelligent control by integration into building management systems … Lower wiring costs … Increased operational security … Maximum flexibility of design and technology Mondrian Building, Brussels, Belgium FSL installation situation decentralised ventilation Hotel Leningrad, Moscow, Russia 9 … Clients now, partners later …… Customer-oriented services are an integral part of the successful ventilation and air conditioning solutions at TROX. They decidedly improve the cost-effectiveness of any property during its life. The customers will profit during all phases of the product life cycle from the competency and solution minded approach of our sales representatives, both for building development, as well as for refurbishment and modernisation. TROX CUSTOMER SUPPORT guarantees quick reaction times and short travel distances during each phase of the programme with its extensive network of services. In the setting of TROX ACADEMY, an in-depth exchange of information and experiences is cultivated by TROX with its customers. TROX offers interested customers either the opportunity to learn about the latest research and development breakthroughs in ventilation and air conditioning technology in seminar format, or to further educate themselves more directly in workshops. As such, many satisfied customers become committed partners. …… 10 … Supporting our customers during the development, procurement, and operation of a ventilation and air conditioning system by: … Individual consulting of new building construction and modernisation projects … Product and programme selection … Measurement (flow rate, acoustics, output) … Project design … Online order tracking … Spare parts/online shop Imperial College, London, UK Seminars and symposia on the following topics: … User-oriented ventilation concepts … Fire and smoke protection … Solutions for laboratory systems … Maintenance and refurbishment of ventilation components Fire protection symposia at fortresses and castles in Germany Did you know… …that air is our most important element of life? A human being can live without food for over a month and without water for about a week, but without air a person can survive no more than three to five minutes at the most. And we need a lot of air to live! While we are quite adequately supplied with two litres of water per day, we breathe around 20,000 litres of air each day. In a poorly ventilated room, the air is quickly used up. The concentration of carbon dioxide mounts rapidly. The results are fatigue and decreased performance. 11 … …… In der Welt zu Hause …… Als international tätiges Unternehmen treffen wir in den verschiedenen Ländern und Regionen der Erde auf die unterschiedlichsten klimatischen und kulturellen Besonderheiten. Ob Südafrika, USA, Brasilien, China oder Europa – TROX sorgt überall für eine wohl temperierte Atmosphäre. Ozeanum, Stralsund (D) Jedes Gebäude ist eine Welt für sich. Flughäfen, Bürogebäude, Krankenhäuser, Laboratorien oder Konzertsäle – sie alle stellen ganz individuelle Anforderungen an die Raumluftund Klimatechnik. Und nicht zuletzt erfordert auch jede technische Anwendung – ob Tunnelklappe, Klimazentralgerät oder MultifunktionsKühl-konvektor – ein spezifisches Know-how. Königliche Oper, Kopenhagen (DK) Soccer City, Johannesburg (ZA) 12 … Auditoruim di Roma, Rom (I) Emirates Palace, Abu Dhabi (V.A.E.) 13 … At home everywhere …… As an internationally active company, we have come into contact with the most pronounced climatic and cultural differences in various countries and regions across the world. Whether in South Africa, the United States, Brazil, China, or Northern Europe, TROX ensures a well-tempered atmosphere. Ozeanum, Stralsund, Germany Each building is a world in and of itself. Airports, office buildings, hospitals, laboratories, and concert halls each have their own completely individual needs for climate control and ventilation technology. And last but not least, each technical application requires specific know-how - whether it is a tunnel damper, a central air handling unit, or a multifunctional chilled beam. Operaen, Copenhagen, Denmark Auditorium di Roma, Rome, Italy Emirates Palace, Abu Dhabi, United Arab Emirates 13 … A strong team worldwide …… The TROX GROUP is a strong team in the global world of ventilation and air conditioning technology, which also provides the best possible service for its customers. As a customer, you will find competent sales representatives and development engineers exactly where you expect them to be: right at your side. Efficient information management makes results developed on-site available to the entire company so that a comprehensive reservoir of unrestricted company knowledge will be at the disposal of each and every employee and thus customer, regardless of their location. The numerous factory sites of the TROX GROUP function independently according to strict quality guidelines. TROX can handle large tasks through the expert use of internationally distributed production capacities in short order and with a guaranteed level of quality. 14 … With perfect technical and creative implementation, TROX makes strides in development to achieve your architectural vision. Set a goal and TROX will find a way to reach it quickly and cost-effectively. Formulate your task description and TROX will find a solution that will excite both your customers and your business partners. Expertise for the world of buildings, in all shapes and sizes … Office buildings … Hotels … Concert and theatre halls … Shopping centres … Recreation centres … Hospitals … Exhibition and congress halls … Sports facilities … Universities … Airports … Train stations … Tunnels … Ships … Laboratories … Clean rooms … Data centres … Automotive sites … Oil platforms … Food processing industry … Power plants … Chemical and pharmaceutical industry National Aquatics Center “Water Cube”, Beijing , China 15 … TROX in Europe Headquarters in Germany TROX GmbH, Neukirchen-Vluyn • Founded in 1951 • TCC: Air-water systems, decentralised ventilation systems, fire and smoke protection components, tunnel dampers, filters, air terminal units, laboratory ventilation systems, communication and automation systems Manufacture and sales Sales subsidiary Sales office Foreign representative TROX Deutschland GmbH, Neukirchen-Vluyn, Germany • Disincorporation in 2008 TROX UK Ltd, Thetford, UK • Founded in 1962 • TCC: Multi-service chilled beams Fan coil units Advanced IT cooling components TROX AITCS Ltd., Thetford, UK • Founded in 2006 • TCC: Advanced IT Cooling Systems TROX HESCO Schweiz AG, Rüti, Switzerland • HESCO founded in 1863 • Acquired in 1998 • TCC: Chilled ceilings Displacement flow diffusers Design diffusers TROX Austria GmbH, Vienna, Austria • Founded in 1962 • Management of all Eastern European sales offices: Bulgaria Croatia Poland Serbia Czech Republic Hungary Romania 16 … TROXCellenceCentre TROXCellenceCentre (TCC) Through its manufacturing and R&D base, TROX has developed considerable specialised expertise in specific system and product types that can be applied across markets. Forming a global network these independent ‘centres of excellence’ aim to serve customers on a world wide basis. TROX Auranor Norge AS, Brandbu, Norway • Auranor founded in 1974 • Acquired in 2005 • TCC: Displacement flow diffusers Air-water systems Design diffusers TROX Sverige AB, Stockholm, Sweden • Acquired in 2005 TROX Danmark A/S, Copenhagen, Denmark • Founded in 1981 OOO TROX RUS, Moscow, Russia • Founded in 2005 TROX España, S.A., Saragossa, Spain • Founded in 1966 • TCC: Central air handling units Fan coil units Tunnel dampers TROX Italia, S.p.A., Milan, Italy • Founded in 1962 • TCC: Filters S.A. TROX Belgium N.V., Brussels, Belgium • Founded in 1967 TROX France Sarl, Paris, France • Founded in 1962 17 … TROX in America, Asia, Africa, and Australia TROXCellenceCentre (TCC) In addition to the country-specific ranges of ventilation and air conditioning components and systems offered in the individual countries, TROXCellenceCentres worldwide use their special product and application knowledge to support the national subsidiaries in the development of their markets. Manufacture and sale Sales subsidiary Foreign representative TROX USA, Inc., Atlanta, United States • Founded in 1981 • TCC: Air-water systems Displacement flow diffusers TROX do Brasil Ltda., Sao Paulo, Brazil • Founded in 1975 • TCC: Central air handling units Filters TROX Argentina S.A., Buenos Aires, Argentina • Founded in 2007 TROX South Africa (Pty) Ltd, Pietermaritzburg, South Africa • Founded in 1970 • TCC: Central air handling units 18 … TROX Middle East (LLC), United Arab Emirates, Dubai • Founded in 2006 TROXCellenceCentre TROX Air Conditioning Components (Suzhou) Co., Ltd, Suzhou, China • Founded in 2001 • TCC: Laborotary air management systems Air handling units Plastic processing technology TROX Hong Kong Ltd, Hong Kong • Founded in 1981 TROX Malaysia Sdn. Bhd., Seremban, Malaysia • Founded in 1994 • TCC: Tunnel dampers TROX INDIA PRIVATE LIMITED, Mumbai, India • Founded in 2007 TROX Australia Pty Ltd, Melbourne, Australia • Founded in 2000 19 … Contents Air terminal devices …… . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 – 32 Swirl diffusers and ceiling diffusers . . . . . . . . . . . . . . . . . . . . . . . . 23 – 25 Slot diffusers and linear ball diffusers . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Combination diffusers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Grilles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Displacement flow diffusers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Floor diffusers and staircase swirl diffusers . . . . . . . . . . . . . . . . . . . . . . 30 Air terminal devices for large rooms . . . . . . . . . . . . . . . . . . . . . . . . 31 – 32 Air-water systems …… . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 – 38 Individual system design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Active air-water systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 – 37 Passive air-water systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Decentralised ventilation systems . . . . . . . . . . . . . . . . . . 40 – 45 …… Individual system design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 – 43 Undersill units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Façade units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Underfloor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Fire and smoke protection components …… . . . . . . . . . . . 46 – 50 Fire dampers and fire protection valves . . . . . . . . . . . . . . . . . . . . . 47 – 49 Smoke extraction dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Smoke protection dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Smoke detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Air terminal units …… . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 – 57 System-powered air terminal units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 Air terminal units with auxiliary power . . . . . . . . . . . . . . . . . . . . . .54 – 55 Shut-off devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 – 57 Detailed information regarding our products and services can be found on our homepage (www.troxtechnik.com) or in our technical leaflets. 20 … Sound attenuators …… Splitters, Splitter attenuators, and circular silencers Filters …… . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 – 59 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 – 64 Filter units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 – 62 Filter media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 – 64 Communication and automation systems …… ........ 66 – 67 Individual system design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Laboratory ventilation systems …… Individual system design . . . . . . . . . . . . . . . . . . . . . 68 – 69 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69 AITCS - Advanced IT Cooling Systems . . . . . . . . . . . . . . 70 – 74 …… System description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Blade server cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Dealer desk cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Plant description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73 Explanation of codes and symbols Design/shape Circular Square Rectangular Flow rate (m3/h) Sizes (mm) L = Length W = Width H = Height D = Depth Materials 21 … Air terminal devices Comfortable luxury in futuristic architecture …… The Marqués de Riscal in Elciego, La Rioja, Spain In the heart of the Rioja wine-growing region in northeastern Spain, renowned architect Frank O. Gehry created a futuristic hotel with an innovative roof construction with almost 1,800 m2 of free-floating titanium sheathing. Rising up like a magnificent chateau of the twenty-first century, the exclusive hotel near the old Bodega of Marqués de Riscal, built in 1858, offers its discriminating guests a breathtaking view of the landscape. The building has 43 rooms and 11 suites, an exquisite wellness area with an indoor pool and fitness centre, a gourmet restaurant, a convention and meeting centre, ballrooms, and the future viniculture museum for the Rioja region. Project: Marqués de Riscal Hotel, La Rioja, Spain Owner: Starwood Hotels & Resorts Worldwide, Inc. Architect: Frank O. Gehry Specialist consultant: IDOM Consultants S.A. HVAC-contractor: AXIMA Sistemas e Instalaciones, S.A. Ventilation solution: Jet nozzles, air terminal units, central air handling units, grilles, fire dampers 22 … For this architectonic masterpiece with its sophisticated concept of space, TROX developed an economical ventilation solution for very high demands. Ventilation units and air terminal units guarantee a comfortable atmosphere in the entire building. In this case, TROX jet nozzles and grilles guarantee an optimum, noiseless air discharge in large rooms, such as the restaurant or corridors. With its high-quality products and short delivery terms, TROX is a reliable, preferred partner for prestigious buildings all over the world. Swirl diffusers & ceiling diffusers Swirl diffusers …… Swirl diffusers are an efficient solution for generating mixed air flows. They also enable a fast exchange of a large volume of air, making them suitable for both large and small rooms. With their wide variety of models and finishes, they can be integrated into any ceiling either suspended from or installed flush with the ceiling. Swirl diffusers are available in various designs and all RAL colours. T-Mobile, Prague, the Czech Republic Type TDV•VDW …… • This adjustable diffuser enables flexible room design, for instance, in office buildings with lightweight partition walls and other system walls. circular; square 60 – 1,300 m3/h 300 – 625 mm 300 – 825 mm Type FD•TDF …… • Since this diffuser can be used almost anywhere, it gives you the option of outfitting buildings with a single uniform design. • These diffuser with their discreet design and fixed blades, are easy to clean. circular; square 110 – 900 m3/h 300 – 625 mm Type FDE …… • This fixed swirl diffuser with a rectangular outlet is popular thanks to its optimised acoustic properties and unique design. • It is especially well suited for large rooms, such as sales areas. Square 400 – 1,400 m3/h 600/625 mm 23 … Air terminal devices Swirl diffusers and ceiling diffusers Types RFD•RA …… • This compact swirl diffuser can be ideally integrated into any ceiling system, such as flush in plaster ceilings or over open grid ceilings. Circular; square 35 – 1,000 m3/h 125 – 400 mm Types DCS•ADD•WD …… • These diffurers are available in individual customer designs or with a selection of attractive perforated plates. Circular; square 35 – 1,500 m3/h 250 – 625 mm 250 – 600 mm Ceiling diffusers …… Ceiling diffusers are a comfortable way to generate mixed air flow quietly, even for high flow rates. They give interior designers a great deal of design freedom since they are available not only in the usual range of shapes, but also in rectangular and linear construction, and they can be equipped with blades, a ball jet or perforated sheet steel construction. They consist of powder-coated sheet steel or anodised aluminium. Hohe Düne Hotel, Rostock, Germany Types DLQ•DLQL•DQ•ADLQ•ADQ•DDQF•LDD …… • With the variety of sizes and shapes available, these types can be used in almost all building areas. 24 … Square; rectangular 110 – 3,000 m3/h 250 – 625 mm L: 400 – 2,000 mm H: 50 – 589 mm Swirl diffusers & ceiling diffusers Types ADLR•DDF …… • The radial air discharge ensures a high degree of comfort. • This ceiling diffuser is also available with a square face plate for integration into modular ceilings. …… Types Pass•CF • These two types were developed for public areas with a great deal of foot traffic. • They save cleaning costs because their specialised air discharges prevent rapid soiling of the outlet and the ceiling. Circular; square 70 – 2,000 m3/h 216 – 654 mm 600 – 625 mm Circular; square 250 – 800 m3/h 500 mm 600/625 mm Types LVS•Z-LVS …… • These easy-to-install ventilation valves are a cost-effective solution for small rooms where you only need to circulate lower flow rates. Circular 10 – 400 m3/h 100 – 200 mm 25 … Air terminal devices Slot diffusers and linear ball diffusers Slot diffusers and linear ball diffusers …… Slot diffusers and linear ball diffusers guarantee effective air discharge that can also be individually modified after installation. With their narrow faces they can easily be architecturally integrated into ceilings, even in rooms with low ceilings. Our continuous linear construction and mitred angle sections also enable ambitious visual effects to be achieved. The finishes are available in various RAL colours or in anodised aluminium. Blue Heaven Radisson Hotel, Frankfurt/Main, Germany Types VSD15•VSD35•VSD50 …… SC•SB • These types are generally suitable for laying along a continuous line and can be inconspicuously installed parallel to linear light arrays. …… Type KS • This ball diffuser rail is a specialised design element that can be adjusted radially or individually fitted to the ceiling profile. …… Nozzle ducts • The nozzle ducts have rotating plastic nozzles and are good supply air elements for suspended ceiling installation. • They bring fresh air into a room with low induction and thus without draughts. 26 … Rectangular; 1 to 4 slots 30 – 500 (m3/h) · m L: 600 – 1,950 mm Rectangular; 1 and 2 slots 30 – 130 (m3/h) · m L: 600 – 2,000 mm Circular 50 – 220 (m3/h) · m 160 – 400 mm L: 500 – 2,000 mm Combination diffusers Combination diffusers …… Modern office buildings, which may for example have low energy requirements thanks to use of concrete core cooling, require small air exchange rates on the one hand, whilst providing very little room for installing the ventilation on the other. In such situations, installing combination diffusers into walls as a mixed or displacement flow system is a compact and cost-efficient complete solution. Grafenberger Höfe office park, Düsseldorf, Germany Types VSD 35-3-AZ•QLW-AZ …… • Air is discharged and extracted through a single element in the wall. • The optional cross-talk sound attenuator effectively suppresses the transmission of sounds from room to room. Rectangular; 3-slot perforated plate 60 – 150 m3/h L: 600 – 1,200 mm H: 110 mm Type VSD 50-1-LT …… • This extraordinarily space-saving combination diffuser with integrated cross-talk sound attenuator can be installed into lightweight partition walls. • It is also available as a combined supply and extract air configuration. …… Type KUD2-ZLAL • This supply and extract air combination with integrated crosstalk sound attenuator has ball jets for the supply air. Exhaust air is taken in through a perforated plate in the bottom half of the diffuser. • The unique ball jets are arranged in two rows. Each jet can be adjusted in any direction, thus making the supply airstreams penetration depth extremely variable. 1 slot 50 – 200 m3/h L: 550/1,175 mm W: 75 mm Double-row jet nozzles, perforated plate 80 – 120 m3/h L: 600 – 1,200 mm H: 200 mm 27 … Air terminal devices Grilles Grilles …… Grilles, the classic amongst the air terminal devices, can be used for supply and extract air. When used properly, they continue to enable low-cost and effective ventilation of rooms. Depending on the construction, they have the flexibility to be adjusted to suit specialised requirements and room partitioning. Linear grilles are a good design-oriented solution. They are made of anodised aluminium or steel and available in various RAL colours. Theatre Municipal, Luxembourg Types AH•AF•EF•EFG•AWT•AGS …… LG • Equipped with fixed blades, these robust grilles are very stable and can be used in doors, floors, walls or ceilings. Types ASL•AT•VAT•SL•TR•TRS•TRS-R …… DGL•DG•DGR • Grilles and linear grilles with adjustable face blades can be installed into walls, ducts, and shafts. …… Types DGVAR•DGSELF • These grilles blow warm supply air downward and cold air upward. They regulate the direction of the airstream either automatically without an auxiliary power or by means of an electric actuator. • In industrial construction, they can also be installed into circular ducts. 28 … Rectangular; available in various frame widths 40 – 7,000 m3/h L: 200 – 1,225 mm H: 50 – 525 mm Rectangular; available in various frame widths 90 – 9,000 m3/h L: 200 – 1,225 mm H: 50 – 525 mm Rectangular 50 – 1,900 m3/h L: 600 – 900 mm H: 100 – 250 mm Displacement flow diffusers Displacement flow diffusers …… Displacement flow diffusers allow cooled fresh air to be discharged into rooms at very low air velocity and close to the floor so that a pool of fresh air forms over the floor. This prevents air turbulence and thus drafts. The air rises when it reaches sources of heat such as people or computers, transferring the heat and the used air to the ceiling. The fresh air quality in the areas occupied by people thus remains at the same especially high level while maintaining a pleasant set temperature. Displacement flow diffusers can also be integrated into wall areas or as columns in a room to save space. They are made of galvanised and powder-coated sheet steel and available in a variety of constructions. Airport, Hamburg, Germany Type QLV …… • The multi-cornered design of this displacement flow diffuser is unique. • It is available in a 90° model for corner installation, a 180° model for wall installation and a 360° model as a freestanding column. 90°/180°/360° 60 – 4,200 m3/h 160 – 630 mm H: 500 – 1,750 mm Types QLE•QLF …… • These two types are notable for their flat, space-saving construction and, with a sloped front panel (QLF), for their elegant design. Rectangular 40 – 3,700 m3/h L: 300 – 1,500 mm H: 150 – 2,000 mm Individual displacement flow diffusers …… • The many shapes and models offer convenient solutions with a wide variety of applications. • They can be used flexibly for different purposes and in different locations. Application-specific dimensions and performance data 29 … Air terminal devices Floor diffusers and staircase swirl diffusers Floor diffusers and staircase swirl diffusers …… Floor and staircase swirl diffusers installed in false floors and hollow flooring are an ideal solution for combining the advantages of mixed air flow with the advantages of displacement air flow. The latter can also be achieved using small diffusers. Use them anywhere you have demanding acoustic requirements: in assembly rooms, auditoriums and stage theatres, or cinemas. They are made of aluminium, plastic or steel sheet metal, with a variety of finishes. Expo 2008, Saragossa, Spain Types FBA•FBK …… • These floor diffusers have been designed to withstand very heavy usage. • They can be used with and without a frame. • Control of discharge characteristics and flow rate via the dirt trap are available as accessories. …… Types IAF•IRF • This type was designed for false floors and provides all the advantages of displacement ventilation. Circular 20 – 180 m3/h 150/200 mm Circular; square; rectangular up to 330 m3/h 300 mm 600 mm 450 x 180 mm Types SD•SDRF …… LDD-ST • These staircase swirl diffusers transfer low supply flow rates into a room whilst quickly reducing their speed so that in theatres, for instance, each seat can be supplied with fresh air quietly and without draughts. • They are installed vertically or horizontally in steps. 30 … Circular; rectangular; square 7– 100 m3/h 180 mm (SD) L: 200 – 500 mm H: 70 mm Air terminal devices for large rooms Air terminal devices for large rooms …… Exhibition halls, airports, manufacturing spaces, lobbies, theatres and other large rooms require high performance ventilation capable of fulfilling the changing requirements of heating and cooling. TROX air terminal devices for large rooms control the air discharge direction of the airstream either manually or with an electric actuator, either discharging warm air downwards or distributing cold air horizontally throughout the room. A variety of configurations are available for every ceiling type, whether suspended or flush. The diffusers are made of aluminium or galvanised sheet steel. Water Tower, Expo 2008, Saragossa, Spain Type VDR …… • This adjustable ceiling diffuser discharges warm air downwards into the room when in heating mode. • It is very quiet and an ideal solution for theatres, studios, multipurpose halls and other sound-sensitive areas. Types VD•VDL …… • These two adjustable swirl diffusers allow warm air to penetrate downwards into a room when running in heating mode and ensure optimum comfort in cooling mode. • When fitted with a protection grid, they can also be installed in gymnasiums. Circular 600 – 8,000 m3/h 315 – 800 mm Circular; square 250 – 8,000 m3/h 315 – 800 mm 425 – 1,050 mm Types ISH•QSH …… • These displacement flow diffusers are primarily used in industrial manufacturing and installed as freely suspended units. • They can be adjusted individually for any temperature range. Circular 700 – 8,000 m3/h 250 – 560 mm 31 … Air terminal devices Air terminal devices for large rooms Type IDH …… • This active chilled beam was developed as an air-water system for rooms with high ceilings and can be installed at heights of up to 25 m. It is installed as a freely suspended unit. • The air discharge direction depends on the temperature. • It has been designed for a maximum cooling output of 25 kW to 28 kW. …… Rectangular 300 – 3,200 m3/h L: 1,500 – 2,500 mm B: 305 – 548 mm H: 1,405/1,840 mm Type PCD • This PROCONDIF® ceiling diffuser discharges air from the ceiling with low turbulences and is suitable for laboratories and kitchens. • It contains a highly permeable honeycomb structure and keeps the ceiling from getting dirty. Circular; rectangular 290 – 600 m3/h 725 mm 600/625 mm Type DUK …… AJA • These two compact jet nozzles are inconspicuous and are used to discharge air for long distances in the room. • They can be adjusted electrically or manually and work in heating or cooling modes. Powerful output, great comfort …… In large rooms such as exhibition halls or airport terminals, providing the desired comfort is always a technical challenge. High flow rates have to be distributed into the room in such a way that the visitors always have a fresh atmosphere without draughts independent of the number of people and the current outdoor temperature. TROX masters this challenge mainly using cleverly positioned jet nozzles that can blow fresh air into the room without draughts. Barajas Airport, Madrid, Spain 32 … Circular 70 – 5,000 m3/h 100 – 400 mm (DUK), 200 – 350 mm (AJA) Human beings are one of the biggest sources of humidity indoors. We lose half a litre of water into the environment each day through our skin alone. Too much humidity makes us feel unwell and minimises our ability to work. At room temperatures of 20 – 24°C, the body radiates about 20 – 35% of its excess heat by evaporating sweat on the skin’s surface. As the temperature rises, our sweat production increases as well, and our cardiac and circulatory problems worsen. At relative humidity levels of 60 – 70 % and temperatures above 25°C, we feel that the air is sticky and oppressive, and our ability to work well falls to a minimum. 33 … Air-water systems Ecologically excellent …… The new home of the European Investment Bank in Luxembourg In the summer of 2008, the European Investment Bank (EIB) formally opened its new home in Luxembourg. In the building having a double façade, conservator, and atria, the approximately 1,600 employees of the bank manage the constantly growing financing volume in the 27 EU member states and 173 partner countries. Project/Owner: Main contractor: Architect: HVAC-contractor: Ventilation solution: 34 … European Investment Bank, Luxembourg Joint venture between VINCI Construction Grands Projets and Compagnie d’Entreprises CFE s.a. Ingenhoven Overdiek Architekten GmbH & Co. KG Imtech Deutschland GmbH & Co. KG 1,800 underfloor induction diffusers (BID) In view of the pending climatic change and increasing energy costs, the EIB has been aiming for environmental certification for the evaluation of the ecological qualities of the new building from the beginning. The result was particularly high requirements on the environmental compatibility of the ventilation technology used. At the same time, the most demanding requirements on further criteria such as air quality, comfort, noise level, flexibility, spatial requirements, maintenance-friendliness, and costs were to be met. Thanks to the early involvement of TROX engineers, an extremely economical ventilation concept consisting of 1,800 underfloor induction diffusers (BID) was realised. Integrated unnoticeably into the rooms’ architecture, these underfloor induction diffusers enable the use of economical air-water systems, even in room-high glazed buildings. The decision to use TROX underfloor induction diffusers paid off. The new EIB building was the first building on continental Europe to be evaluated as “Very Good” according to the particularly comprehensive BREEAM environmental certification method. Individual system design COMBEAM®: Air-water systems that can do it all …… Air-water systems use heat exchangers to cool and/or heat indoor air by means of water-based heat exchangers. The system saves energy because it takes less power to transport heat away in water than in air. Air-water systems can be installed in open or suspended ceilings and are very well suited for refurbishment projects. We differentiate between active and passive chilled beams. COMBEAM® or multi-service chilled beams, the multifunctional air-water systems from TROX, not only provide the normal heating, cooling and ventilation functions, but can also be equipped with extra building services, enabling space-saving integration of lighting, smoke detectors, loudspeakers and sprinkler systems. COMBEAMs can also be designed in the form of design elements to accentuate a building’s architecture, for example, as ceiling sails or as inconspicuous ceiling installations. The option of smooth integration into centralised building communication and control systems is also possible. Type MDF multi-functional ceiling sail, installed in the Chambre de Commerce of Luxembourg, designed by Claude Vasconi and Jean Petit Motion detector Advantages for installation and refurbishment • Shortened construction period thanks to integral prefabrication • Easy installation (plug-and-play) • Significant reduction in interfaces • Reduction in ceiling void height • Reduced investment costs • Faster return on investment Advantages in operation • Energy savings • Low maintenance and operating costs • Flexibility for changes of use Smoke detector Sprinkler 35 … Air-water systems Active air-water systems Active air-water systems …… In the case of active air-water systems, fresh air is supplied to rooms from the central plant in addition to water cooling. In comparison to pure air systems, the fresh air volume required for a person’s well-being can be reduced to one-third. Because the system is based on the principle of induction, no extra fans are necessary to transport the air, thus saving energy and reducing noise to an absolute minimum. Active air-water systems are mostly called active chilled beams. These systems save space because they allow you to reduce the size of the central plant systems and supply ducts, and their installation height is very low. They are operationally reliable and low-maintenance because they do not contain any moving parts. They run in both cooling and heating mode, which means you do not need to install extra static heaters. Constitution Center, Washington DC, USA Types DID312•DID300B•DID600B•DID600B-L …… • These active chilled beams are available with optional integrated lighting and extract air systems. • Their supply air discharge is comparable to that of the slot diffuser. • Active chilled beams can be installed parallel or at 90 degrees to the façade. • The DID300 can also be operated under wet coil conditions. Rectangular 10 – 220 m3/h L: 900 – 3,000 mm W: 300/600 mm H: 210 – 240 mm Cooling capacity: up to 1,600 W Heating capacity: up to 1,600 W Type DID-R …… • Type DID-R active chilled beams are especially well suited for upgrading pre-existing tee bar ceilings and for integration into plaster ceilings. • Their supply air discharge and ceiling installation is comparable to that of the classic ceiling diffusers. • The DID-R can also be operated under wet coil conditions. 36 … Circular; square 40 – 80 m3/h 600 mm 600/625 mm H: 250 mm Cooling capacity: up to 500 W Heating capacity: up to 1,200 W Active air-water systems Type DID-E …… • Type DID-E active chilled beams are installed into a formed plaster board bulkhead. • There is a wide variety of options for configuration of the air inlet and discharge openings. • They are especially well suited for hotel bedrooms, hospitals and individual offices. 20 – 130 m3/h L: 700 mm W: 900/1,200/1,500 mm H: 200 mm Cooling capacity: up to 1,500 W Heating capacity: up to 1,500 W Type AKV …… • This attractive active chilled beam can be used with or without a false ceiling. Rectangular 40 – 290 m3/h L: 900 – 3,000 mm W: 300/500 mm H: 200 mm Cooling capacity: up to 1,600 W Heating capacity: up to 1,600 W Type BID …… • The underfloor induction diffuser is the air-water solution for installation into false and void floors in case of room-high glazed buildings without false ceilings. • Due to a cooling system in the vicinity of the façade during summer operation, the heat radiation on the façade is minimised, whilst the reduction of cold air near the façade is prevented during heating operation. Rectangular 10 – 150 m3/h W: 1,100 – 1,800 mm H: 190 mm D: 404 mm Cooling capacity: up to 1,300 W Heating capacity: up to 1,300 W Type QLI …… • This induction type displacement flow diffuser is installed under sills. • It is a simple retrofitting solution for buildings containing high-pressure induction units. Rectangular 10 – 180 m3/h L: 900/1,200/1,500 mm H: 730 mm D: 200 mm Cooling capacity: up to 1,000 W Heating capacity: up to 1,000 W 37 … Air-water systems Passive air-water systems Passive air-water systems …… Neither ventilation systems nor fans are required to operate passive air-water systems. Hot air rises, is cooled by the water cooling elements and falls back into the room. We recommend a combination with air systems for optimum air conditioning and ventilation. Controlled air humidity ensures condensate-free operation with optimum and noise free cooling. Burda Publishing House, Offenburg, Germany Type PKV …… • Type PKV chilled beams have a large performance range during cooling operation. • They give interior designers a great deal of freedom in designing rooms. • They can be an optimum supplement to existing systems for dealing with high heat loads. Rectangular L: 900 – 3,000 mm W: 180 – 600 mm H: 110 – 300 mm Cooling capacity: up to 1,500 W Type WK-D-WF …… WK-D-EL Cooling capacity according to DIN EN 14240 (8K): 130 W/m2 • Chilled ceilings with high output for freely suspended mounting as a ceiling sail. • Beautifully shaped design in various finishes. Types WK-D-UL•WK-D-UM …… WK-D-UG • These chilled ceiling systems provide a high degree of comfort thanks to their radiant cooling area. • They can be used as lay-in elements in metal ceiling tiles or incorporated into a plaster ceiling. 38 … Cooling capacity according to DIN EN 14240 (8K): 80 W/m2 When the air is too dry, it can make you ill. In winter, heating frequently makes the air far too dry. This often results in sore throats, sinus infections and susceptibility to colds. About one-third of all sick days are taken due to illnesses affecting the respiratory passages. Good indoor air quality, ensuring optimum good health, not only keeps employees fit but pays off for employers, too. 39 … Decentralised ventilation systems More flexibility in new construction due to decentralised ventilation …… The “Laimer Würfel” building in Munich, Germany In the Laim quarter of Munich near the downtown area, the “Laimer Würfel” (Cube of Laim) is a contemporary office building characterised by its efficient use of space and individuality. The building has eleven upper floors with about 1,900 m2 gross floor area and a multifunctional circular floor, which also has a convention area and casino in addition to shops. Large plant rooms inside the building and branched, space-consuming air duct works are made superfluous by the use of decentralised façade ventilation units, thus increasing useful floor space. The decentralised ventilation units of TROX/FSL are also designed to save energy and be maintenance friendly, whereby the operating costs are minimised. Project: Laimer Würfel, Munich, Germany Owner: HOCHTIEF Projektentwicklung Architect: FRICK KRÜGER NUSSER PLAN 2 Specialist planer J. Weißenhorn - CAE - H. König Ventilation solution: Decentralised sill units for supply and extract air, as well as secondary air units (FSL-B-ZAB) 40 … At an early construction stage, 1,600 frames were integrated into the outer façade. 800 frames were equipped with decentralised ventilation units. They filter the supply air, provide for, ventilation, and heat recovery, and heat or cool. To achieve the required heating and cooling capacities, 540 additional frames were equipped with secondary air units that can heat or cool the indoor air during pure secondary air operation. The other 260 frames casings act as a reserve and are initially only equipped with insulation boxes for noise and heat insulation. They can later be retrofitted with TROX/FSL ventilation units. The frame type of construction makes it possible to react to changes in use in the office building in an fast, cost-effective manner. Individual system design More individuality with minimised investment and energy costs …… In our decentralised façade system ventilation (FSL) solution, we integrate sound-absorbing ventilation units into a building’s exterior. These units can be installed under sills or into walls or false floors. They discharge fresh air into rooms and/or exhaust air out along the shortest possible route. Both in construction and in retrofitting, TROX decentralised, individually controllable ventilation systems offer a rich variety of design options for ventilating a building. Clients can install a complete decentralised ventilation system or combine the decentralised supply air system with a central extract air system. The product variation ranges from simple flow devices to complex systems with heating and cooling functions and integrated individual room regulation (FSL-CONTROL). Decentralised ventilation systems provide numerous advantages. Individual users can adjust the air quality and room temperature in their rooms according to their own individual tastes. For investors, TROX systems are economical, energy-saving and, above all, flexible solutions that can be re-adapted at any time with very little work to suit change of use. In developing decentralised ventilation units, TROX takes its inspiration from the inventiveness and design resourcefulness of architects to find solutions in which functionality and design merge into an ideal whole. With our cost-efficient prefabrication of façade elements, TROX provides investors with integral construction, reduced installation times and reduced interfaces. Lighttower, Frankfurt/Main, Germany Advantages • Individual heating, cooling, and ventilation • Air filtration • Noise insulation • Heat recovering • Night cooling with the windows closed • Construction cost reductions due to low slab-to-slab heights • Flexible equipping and retrofitting • Low operating costs Pre-mounted façade with integrated building services Lighttower, Frankfurt/Main, Germany 41 … Decentralised ventilation systems Individual system design Creative solutions for the refurbishment of existing buildings …… Office complex in Frankfurt am Main, Germany Existing standard solutions in ventilation technology can often not be used for the refurbishment of existing buildings. Here, companies that can make state-of-the-art technology usable in traditional architecture with creativity and flexibility are in demand. In this area, TROX/FSL has been able to prove its capabilities, especially during the refurbishment of an office complex in Frankfurt. For the refurbishment of the air conditioning system of Feldbergstraße 35, a building in which the German representative of the British National Westminster Bank AG has its headquarters, TROX developed a special ventilation solution between the sill and the ceiling together with the building owners and architect. Project: Office complex, Frankfurt/Main, Germany Owner: CB Richard/Ellis Investors Architect: Collignon Architektur Specialist consultant: INTEG Dipl.-Ing. Georg Mayer & Partner HVAC-contractor: KLU Klima-Lüftungs-Umwelttechnik KG Ventilation Façade-integrated sill ventilation solution: units with supply and secondary air functions (FSL-B-ZUS) Decentralised ventilation unit 42 … The spatial conditions and usage plans required a ventilation concept that could make do without a horizontal air distribution system. Only in this way could the setup of combination and open-plan offices continue to be possible. In the research and development laboratory of TROX/FSL, extensive flow tests were performed to meet the project requirements. The advantage in the use of decentralised units was that no suspended ceilings were required for ducts. The high flexibility through the single room control and user-adapted settlement possibilities were an additional advantage. Further examples for the decentralised sill ventilation solutions of TROX/FSL are the Imtech Haus in Hamburg, the Laimer Würfel in Munich, and the Lighttower in Frankfurt/Main. Individual system design Decentralised ventilation a clever refurbishment alternative …… Complex refurbishment projects confront planners of the technical building equipment with sophisticated problems. Here, a special focus is on optimum, modern air conditioning and ventilation technology. In the process, decentralised ventilation units are increasingly forming the starting point for innovative solutions since they offer great freedom for design and fulfil modern usage requirements. A decisive advantage lies in the lack of duct work. Decentralised ventilation units are installed near or into the outer façade so that the ventilation of the stories takes place directly via the outer façade. This leads to short transport distances with low pressure losses. At the same time, the façade becomes an active component that can assume further air conditioning functions. Through the preassembly of individual components or complete, multifunctional façade modules at the manufacturer’s factory, the assembly and installation work on-site is strongly reduced. If the user is not present, the units switch to standby mode or they are switched off. The energy required for operation can be determined simply so that the energy costs can be settled based on consumption. This motivates the users to use energy more sparingly since they can actively sink their individual operating costs in this manner. Water as an energy-carrying medium FSL units dissipate thermal loads using an air-water heat exchanger. Water as an energy-carrying medium has a high specific heating capacity and lower specific volume than air. In comparison with a given air flow rate, the same thermal load can be dissipated as with a lower water rate flow. As a result, the cross-sections of the transport lines can be reduced. This and the elimination of the duct works can considerably reduce the transport energy expended. Bürkleinhaus, Munich, Germany Supplementary air conditioning systems In many indoor climate concepts, ventilation systems are supplemented by additional systems to achieve high and better comfort. Chilled ceilings, for example, are particularly well suited for dissipating higher thermal loads. INSIDE OUTSIDE Façade ventilation solutions 43 … Decentralised ventilation systems Undersill units Undersill units …… Undersill units are decentralised ventilation units that can be integrated underneath the window. They are available as pure supply air units, extract air units, or combination supply and extract air units. Type FSL-B-60 …… • This undersill unit can be easily installed above or below a window or in façade profiles, as it can be installed either vertically or horizontally. • It contains a manually operated air control blade and a sound insulating element that allows a natural transfer of low flow rates while preserving good insulation properties. 10 – 50 m3/h H: 60 mm; Variable depth and width Unit standard sound level difference up to 47 dB Type FSL-B-100 …… • This façade ventilation unit for office, hotel and residential applications has very high sound absorption levels and enables modular, user-oriented implementation. • The natural ventilation flow can be augmented with a fan. • It can be configured as a supply or exhaust air unit. 30 – 80 m3/h H: 100 mm; Variable depth and width Unit standard sound level difference up to 57 dB Type FSL-B-190 …… • Integration of supply and exhaust air functions in the smallest possible volume, including fans and heat recovery. • There are a number of equipment options, allowing it to be used in a multitude of ways e.g. in schools, seminar rooms, hospital ward blocks, and hotels. • Optionally available with a heat exchanger for heating and cooling modes and with a thermal switch for static heating. 60 – 120 m3/h H: 190 mm; Variable width Cooling capacitiy: max. 560 W Heating capacity: max. 1,750 W Unit standard sound level difference up to 52 dB Type FSL-B-ZAB …… • Individually and flexibly usable due to preassembled frame module construction with freely selectable functions. • Function box, optionally with supply and extract air function or secondary air function or as insulation box. • The plug-and-play principle: ready-for-operation delivery – plug it in – done. 44 … 90 – 180 m3/h W: 946 mm H: 585 mm D: 491 mm For 120 m3/h Cooling capacity: max. 560 W Heating capacity: max. 2,000 W Façade units | Underfloor units Façade units …… Façade units are attached to the sill or are parts of the façade. Type FSL-B-ZUS …… • Sill ventilation units with supply and secondary air functions are used for the decentralised ventilation of rooms and buildings. • In addition to the supply of fresh air, the units have heating, cooling, and filtering functions. • For energetically optimised use, secondary air is added in case of an increased heating or cooling load. • The units are developed in a project-specific manner and adapted to the on-site boundary conditions. 75 – 210 m3/h W: 350 mm H: 1,880 mm D: 300 mm Cooling capacity: max. 840 W Heating capacity: max. 2,150 W Underfloor units …… Underfloor units were developed in particular for buildings with room-high glass façades. The units, which are integrated into false floors, are available with a pure supply air function, as supply/exhaust air combinations, or as supply air units with secondary air admixture. Type FSL-U-ZAB …… • As a convenient supply and exhaust air unit with integrated heat recovery, this is a high-quality replacement for a central ventilation plant. • Static heating is possible when the ventilation is switched off. 60 – 120 m3/h Unit height: 203 mm Grille width: 500 mm Cooling capacity: max. 560 W Heating capacity: max. 1,680 W Type FSL-U-ZUS …… • A narrow, attractive linear grille discharges conditioned supply air into the room for heating or cooling. • This unit works extremely quietly. • Energy consumption is optimised by limiting the outdoor air flow rate which is mixed with recirculated air, with high heating and cooling performance standards. 60 – 200 m3/h Unit height: 180 mm Grille height: 230 mm at 90m3/h outside air Cooling capacity: max. 740 W Heating capacity: max. 1,580 W 45 … Fire and smoke protection components Safe start …… Fire damper in Moses Mabhida Stadium Durban, South Africa In Durban on the east coast of South Africa, the Moses Mabhida Stadium is currently being built for the 2010 Football World Cup. It is the second largest stadium of the Football World Cup 2010 and has room for 70,000 spectators. Two large steel arches span the stadium roof at a height of about 104 metres. © Macina Project: Moses Mabhida Stadium, Durban, South Africa Owner: eThekwini Municipality Architect: gmp - Architekten von Gerkan, Marg und Partner, International Contractor: Group Five, WBHO, Pandev JV Specialist IBHOLA LETHU CONSORTIUM / consultant: LSG International HVAC-consultant: I.E.S. Improvair Enviromental Solutions Ventilation solution: Centralised air conditioning units, fire dampers, swirl diffusers (VDL), disc valves (LVS), various ceiling diffusers © Macina 46 … This “skywalk,” which can be reached by a cable car and a stairway with 550 steps, offers a spectacular view of the city and the Indian Ocean. In addition to the athletic facilities, the stadium has a sports museum and a sports institute. After completion, the stadium forms the focus of the planned Kings Park athletic quarter. In such large public buildings, special attention is always paid to fire and smoke protection. This particularly applies for football stadiums in which the safety of several thousand people must be guaranteed even in case of a fire. In addition to numerous other components for ventilation and air conditioning, TROX supplies fire dampers for the high-prestige new construction project in South Africa. © Macina Fire dampers and fire protection valves Fire and smoke protection components …… For fire and smoke protection components, extensive fire and suitability tests have been legally required. The usability or applicability within the scope of local construction ordinances are certified in the form of general building inspectorate silence from the Deutsches Institut for Bautechnik (German Institute for Construction Technology) in Berlin. In fire and smoke protection, TROX is the market leader for the areas of new construction and refurbishment, which means that experienced maintenance companies are familiar with the products of TROX. TROX gives maintenance and servicing companies the knowledge they need in certified training programmes. Furthermore TROX offers a telephone support line to assist in selecting and installing the right products. TROX makes it convenient for everyone involved. All TROX approvals have been listed on a well-organised CD from the approval for the first fire damper in 1974 to the approvals for todays products. An extensive spare parts service rounds off the services offered by TROX in the area of fire protection. From fusible links and ancillary items to refurbishment dampers, TROX has the widest range of replacement parts available on the market. Fire dampers and fire protection valves …… Fire dampers have to close after a certain temperature is reached, sealing off sections of a building to prevent the spreading of fire and smoke. To prevent smoke from spreading at temperatures below the temperature that triggers the thermal release, fire dampers can also be closed by optional smoke detectors. Fire dampers require approval. TROX provides the right fire damper with general building inspectorate licence for every installation situation. DaimlerChrysler, Sindelfingen, Germany Types FKRS-EU•FKR-K90 …… • Our circular fire dampers are installed both in solid walls and ceilings and in lightweight partition walls. • They are available in various diameters. • The FKRS-EU is the first fire damper approved for use in all of Europe. Circular Type FKRS-EU 100 – 315 mm Type FKR-K90 200 – 710 mm Fire resistance class: max. EI 120 and K 90 47 … Fire and smoke protection components Fire dampers Type FKS-EU …… • This small rectangular fire damper was also designed for integration into both solid walls and ceilings and lightweight partition walls. • This fire damper is also also approved for use in all of Europe. Rectangular W: 200 – 800 mm H: 100 – 200 mm Fire resistance class: EI 90 und K 90 Type FK-K90 …… • These large rectangular fire dampers can be installed not only in solid walls and ceilings and lightweight partition walls, but also on the outside of walls and ceilings. Rectangular W: 200 – 1,500 mm H: 200 – 800 mm Fire resistance class: max. EI 120 und K 90 Type KU-K30 …… • This ceiling plenum box with integrated fire damper has been approved for installation into fire-resistant false ceilings. Square 300 – 625 mm Fire resistance class: K30-U Type E01-K90 …… • This large rectangular fire damper is suitable for installation as a refurbishment damper in solid walls and ceilings. 48 … Rectangular W: approx. 300 – 1,500 mm H: approx. 300 – 800 mm Fire resistance class: K 90 Fire protection valves | Smoke extraction dampers Types FV-K90•FVZ-K30 …… • These fire protection valves can be installed in solid walls and ceilings, lightweight partition walls and fire-resistant false ceilings (F30). Circular 100 – 200 mm Fire resistance class: K 30 U and K 90 Type FVS-K90 …… • This fire protection valve is for installation into ventilation systems in accordance with DIN 18 017-3. Circular 100 – 200 mm Fire resistance class: max. K 90 Smoke extraction dampers …… Smoke extraction dampers are an important part of mechanical smoke extraction systems, which are meant to keep escape routes, for example, free in case of fire. Smoke extraction dampers are all basically equipped with electric actuators and must remain functional for over 25 minutes during a fire. Type EK-01 …… • This smoke extraction damper is suitable for installation into solid walls and ceilings, lightweight partition walls and on the face of walls. Rectangular W: 200 – 1,500 mm H: 200 – 800 mm Fire resistance class: max. EK90 Type EK-02 …… • This dual-function smoke extraction damper was designed for smoke extraction systems with additional ventilation functions. Usage and available sizes match those of Type EK-01. • The required functionalities are realised by using a TROXNETCOM® solution. Rectangular W: 200 – 1,500 mm H: 200 – 800 mm Fire resistance class: max. EK90 49 … Fire and smoke protection components Smoke protection dampers | Smoke detectors Smoke protection dampers …… Smoke protection dampers are used to prevent smoke from spreading in central ventilation plants with full fresh air systems to systems in which the supply air is mixed with recirculated air and in older systems to make them smoke safe. They are not suitable for taking over the function of fire dampers. Type JZ-RS …… • Smoke protection dampers are basically equipped with spring return actuators. Smoke detectors …… Smoke detectors are used to detect smoke in ventilation systems. Type RM-O-VS-D …… • This smoke detector has a wide range of functions for selfmonitoring (dirt contamination, air flow, electronics) and only requires maintenance on an annual basis. • It is optionally available as a BUS-enabled version. • Permissible air velocity is 1 to 20 m/s. Type RM-0-3-D …… • The smoke detector has extensive self-monitoring (dirt contamination, electronics) and must only be maintained once a year. • The application depends on the direction of air flow. • Permissible air velocity is 1 to 20 m/s. 50 … Rectangular W: 400 – 2.000 mm H: 345 – 1,995 mm More than 80 % of the deaths that occur in fires are due to smoke poisoning. In the toxic smoke, people lose consciousness after only two to three breaths. Our lungs cannot withstand much, especially in conjunction with high temperatures; they start to become damaged at 65°C. In nine out of ten cases, fires undergo a relatively long initial smoldering phase in which they produce a great deal of smoke but relatively little heat. 10 kg of foam, for example, will produce a volume of flue and fire gases of 25,000 m3. Intact, well-coordinated fire safety systems and modern building communication and control systems will detect fires early, prevent smoke from spreading within the building and exhaust the flue gas. 51 … Air terminal units Pleasant climate from North Cape to the South Sea …… Solstice cruise ships of the Celebrity Cruise For years, the Meyer shipyard has been building luxury liners for exclusive cruises for the American shipping company Celebrity Cruise. With Celebrity Solstice, which started its maiden voyage at the end of 2008, and its sister ships Celebrity Equinox (completion in 2009) and Celebrity Eclipse (completion in 2010), the Celebrity Cruises’s largest and most luxurious ships ever are being built. Every ship is 315 metres long and has room for 2,800 passengers. © Meyer Werft GmbH Project: Celebrity Solstice cruise ships, Celebrity Equinox and Celebrity Eclipse. Contractor: Meyer shipyard, Papenburg, Germany HVAC-contractor: Imtech Deutschland GmbH & Co. KG Schiffsbau-/Dockbautechnik Ventilation solution: Volume flow controllers (RN;EN), various air terminal devices, like grilles, ceiling diffusers (DLQ, ADLR), jet nozzles (DUK), and slot diffusers (VSD 35) More than 80% of the fully air-conditioned cabins have a balcony. Wellness areas, spa landscapes, exquisite restaurants, and stages provide for the well-being and entertainment of the passengers. A ship places other demands on indoor ventilation and air conditioning technology than a building. When the Solstice class luxury liners sail the seven seas at 24 knots in every wind and weather and set anchor in all climatic zones, the passengers on board should always enjoy a consistently pleasant climate. For this reason, among other things, particularly flexible volume flow control is needed. TROX has solved this task very well with air terminal units of the Type RN, RN stainless steel, and EN. In addition to the required flexibility, TROX was also able to reduce the power consumption of the air conditioning and ventilation system considerably. © Meyer Werft GmbH © Ingrid Fiebak-Kremer 52 … © Ingrid Fiebak-Kremer System-powered air terminal units System-powered air terminal units …… This type of controller eliminates conventional balancing dampers and thus the time-consuming and expensive work of balancing and adjusting the flow rates in the building. With Types RN and EN controllers, the desired flow rate can be simply adjusted manually using the scale located on the outside of the unit. These air terminal units were designed for constant flow rates but are also available with motorised flow rate adjustment. The casing and the damper blade are made of galvanised sheet steel. In the case of the Type VFC, the damper blade is made of plastic. The controllers are generally maintenance free. The plastic Type VFL volume flow limiter is easy to insert into circular ducts. It limits the flow rate to the set value and maintains it at a constant level within a close tolerances when changes in pressure occur. Nuremberg Fairgrounds, Nuremberg, Germany Type RN …… • This air terminal unit for circular ducts can, for instance, be used in front of air terminal devices. • This classic controller was developed back in 1975 and, after being updated in the 1990s, remains the market leader in the area of constant air terminal units. Circular 80 – 400 mm 40 – 5,040 m3/h Δp: 50 – 1,000 Pa Casing air leakage complies with DIN EN 1751, Class C Type EN …… • This controller is designed for rectangular ducts and high flow rates. Square; rectangular W: 200 – 600 mm H: 100 – 600 mm 144 – 11,800 m3/h Δp: 50 – 1,000 Pa Casing air leakage complies with DIN EN 1751, Class B Type VFL …… • The VFL is a plastic volume flow limiter. • It helps balance and adjust volume flow rates, for example, upstream of air terminal devices. • In addition to their more typical application in commercial buildings, volume flow limiters can also be used in residential areas. Circular 80 – 250 mm 15 – 900 m3/h Δp: 30 – 300 Pa Type VFC …… • The VFC is a circular air terminal unit for low air velocities. • The selection is based on the nominal size of the duct. • Commissioning can be performed easily without the use of special tools. • An actuator can be easily retrofitted. Circular 80 – 250 mm 22 – 1,322 m3/h Δp: 30 – 500 Pa Casing air leakage complies with DIN EN 1751, Class C 53 … Air terminal units Air terminal units with auxiliary power VARYCONTROL®: Air terminal units with auxiliary power …… With these air terminal units, you can individually adjust the inside air temperature and/or quality by means of the supply air flow rate. The system only supplies the amount of air required, which saves energy. VARYCONTROL® units can also be used as duct or room pressure controllers. They have electronic or pneumatic control components. Hamburg Airport, Hamburg, Germany The Easy type …… • Air terminal units with TROX electronic compact controllers for easy handling. • The easy selection of the units, by nominal diameter only, and the easy adjustment of the flow rates at the construction site will save you money during design, installation and commissioning. • The function test takes place directly on the controller using the service button and function display with indicator light. • The following types are available: TVR-Easy, TVJ-Easy, TVT-Easy, TVZ-Easy. Features according to unit type: • TVR • TVJ • TVT • TVZ • TVA Types TVR•TVRK …… • These air terminal units are used in circular ducts. • They are suited for medium and low acoustic requirements. • For higher acoustic requirements, you can use silencers and acoustic cladding. Types TVJ•TVT …… • These air terminal units are used in rectangular ducts. • They are suited for medium and low acoustic requirements. • For higher acoustic requirements, you can use silencers and acoustic cladding. 54 … Circular 36 – 6,048 m3/h 100 – 400 mm Low leakage according to DIN EN 1751, Class 4 or 3 Casing air leakage complies with DIN EN 1751, Class C. Rectangular 162 – 36,360 m3/h W: 200 – 1,000 mm H: 100 – 1,000 mm Low leakage according to DIN EN 1751, Class 4 or 3 Casing air leakage complies with DIN EN 1751, Class A. Air terminal devices with auxiliary power Types TVZ•TVA …… • These air terminal units with integrated silencers can be used in case of high acoustic requirements. Circular; rectangular 54 – 6,048 m3/h 125 – 400 mm Low leakage according to DIN EN 1751, Class 4 or 3 Casing air leakage complies with DIN EN 1751, Class A. Type TVM …… • The Type TVM dual duct terminal box controls room temperature by mixing warm and cold air. • The TVM unit is designed for comfort VAV systems and meets high acoustic requirements thanks to its integrated silencer. Circular; rectangular 162 – 6,048 m3/h 125 – 400 mm Low leakage according to DIN EN 1751, Class 4 or 3 Casing air leakage complies with DIN EN 1751, Class A. Type TVRC …… • The Type TVRC comfort air terminal unit was specially developed for the variable flow rate control of ship cabins or hotel rooms. • The TVRC is used in conjunction with either an optional room control unit and integrated temperature sensor or with a centralised direct digital control (DDC) system. • The integrated electric air heater eliminates the need for any other heating systems in the room. • A LONMARK®-compatible variant is available (Siemens version). Circular 72 – 1,152 m3/h 125 – 200 mm Casing air leakage complies with DIN EN 1751, Class B VAV-EasySet …… • The TROX VAV-EasySet is a set of control components for refurbishing air terminal devices. • One typical application is the replacement of velocity sensors. The old control dampers can be reused, which saves money during refurbishment. Suited for systems with circular ducts. 35 – 6,035 m3/h For 100 – 400 mm 55 … Air terminal units Shut-off devices Shut-off devices …… Shut-off dampers are for ventilation systems in which areas have to be isolated for certain operating situations for safety reasons. Multileaf dampers are used to isolate and restrict the air flow in ducts and other openings. External louvres provide good protection to keep rain, leaves, and birds from getting into the supply and exhaust openings of ventilation systems. Pressure relief dampers and non-return dampers are used to isolate individual sections in ventilation systems. When the fan is running, the blades open; the degree of opening depends on the air velocity through the unit. When the fan is switched off, the blades close automatically. Combinations of external louvres and multileaf dampers or pressure relief dampers have a dual function in supply and exhaust openings of ventilation systems. They keep rain, leaves and birds from getting in, but also restrict or isolate the air flow during ventilation system downtime. Pressure relief dampers close automatically when a malfunction leads to excessive pressure differences in duct works. Types AK•AKK•TDK …… • These circular dampers have many applications. • They are available with manual or motorised adjustment. • Shut-off dampers are made of coated steel or plastic. Circular 80 – 400 mm Low leakage according to DIN EN 1751, Class 4 or 3 (not TDK) Casing air leakage complies with DIN EN 1751, Class C Types JFO•JFP …… • The tunnel dampers are available in various designs. If required, several basic modules are combined to one damper unit. • They are made of steel or stainless steel. • Bearing elements are made only of stainless steel or special bearing materials. Rectangular, square W: max. 2,000 mm H: max. 2,000 mm Types JZ•JNE•JZ-L•JZD-G …… • Multileaf dampers are available in a variety of designs depending on customer requirements. • They are made of steel, stainless steel, or aluminium. Rectangular W: 200 – 2,000 mm H: 100 – 1,998 mm Types WG•WGE•AWG•AWK•WG-F•NL …… • External louvres are available in single or multi-sectional units and in a design for façade installation. • They are made of steel, stainless steel, or aluminium. • The Type NL provides weather and sound protection combined. 56 … Rectangular W: between 97 – 2,400mm depending on type H: between 97 – 2,310mm depending on type Shut-off devices Types UL•KUL …… • Pressure relief dampers are used to shut-off supply and exhaust openings in ventilation systems. • They are manufactured from steel or aluminium. Rectangular W: 300 – 1,600 mm H: 215 – 1,615 mm Types WG-JZ•AWG-JZ•WG-KUL•AWG-KUL …… • Various combinations of external louvres and multileaf dampers or pressure relief dampers. Rectangular W: 400 – 2,000 mm H: 345 – 1,995 mm Types ARK•ARK 1 …… • This non-return damper is used to isolate individual sections of ventilation systems. • The permissible pressure load amounts to 5,000 Pa. Rectangular W: 200 – 1,200 mm H: 345 – 1,995 mm Type ARK2 …… • This pressure relief damper is used where a risk of overpressure exists. • The opening differential pressure is set at the factory. • For dampers of up to 600 mm in width, the opening differential pressure is 50 – 1,000 Pa. For dampers wider than 600 – 1,200 mm, the maximum is 600 Pa. Rectangular W: 200 – 1,200 mm H: 345 – 1,995 mm Type NAK (gas-tight) …… • This shut-off damper is for ventilation systems in which areas have to be isolated with a high degree of seal-tightness (gas-tight) under certain operating situations for safety reasons. • The permissible pressure load amounts to 5,000 Pa. • The maximum permissible leakage according to KTA 3601 or DIN 25414 amounts to 0.01 m3/h · m2 at a differential pressure of 2.000 Pa. Rectangular W: 400 – 1,000 mm H: 270 – 1,000 mm 57 … Sound attenuators Oasis of peace on Red Square …… The Ritz-Carlton in Moscow, Russia The exclusive Ritz-Carlton luxury hotel lies in the direct vicinity of Red Square on Tverskaya Street, the main boulevard of Moscow. The rooftop terrace on the twelfth floor provides a unique view of the Kremlin, Red Square, St. Basil’s Cathedral, and the Cathedral of Christ the Saviour. With its 334 spacious rooms and suites, the magnificent building was built in the Imperial Russian style and offers its guests an exquisite, incomparably comfortable ambience. Inside, select materials like marble and fine woods were used. Project: Ritz Carlton Hotel, Moscow, Russia Owner: Hotel Consulting & Development Architect: Andrei Meerson Investor: Red Square Development Company Specialist consultant:POLIMEKS LIMITED LIABILITY COMPANY HVAC-consultant: POLIMEKS LIMITED LIABILITY COMPANY Ventilation Attenuators and splitters solution: (various MSA and MKA type), air terminal units (TVZD), such as grilles (ASL), ceiling diffusers (DLQ), slot diffusers (VSD), and jet nozzles (DUK-V) 58 … High demands were placed on the air conditioning system, especially in regard to comfort and noise protection. In the middle of the hectic Russian capital, the hotel should be an oasis of peace and comfort. For this project, TROX developed an energy-saving, noise-insulating ventilation and air conditioning concept. TROX Types MSA 100 and MSA 200 splitter attenuators and Types MKA 100 and MKA 200 splitters were used. With their profiled splitter frames that aid flow, the latter reduce the pressure drops in comparison with conventional splitters by up to 30%, which makes high energy savings possible in system operation. The splitters are hygienically tested according to VDI 6022. This guarantees that the materials used are generally recognized as safe and do not provide a breeding ground for microorganisms. Splitters | Splitter attenuators | Circular silencers Attenuators …… In ventilation systems, noise stems from a variety of components such as fans, air terminal units, or fire dampers. To comply with a specified noise level, attenuators are added to suitable locations in the ventilation system. The attenuators should have adequate silencing capabilities and low air resistance, as well as being as small as possible. With the introduction of VDI 6022, specific hygiene requirements for air conditioning systems have bee set up for the first time. Splitters and splitter attenuators from TROX are certified for use in air conditioning systems in accordance with VDI 6022 Parts 1 and 3, DIN 1946 Part 4, and VDI 3802. Types MKA•XKA …… • With respect to conventional splitters, the aerodynamically formed splitter frames reduce pressure drops by up to 30% and thus the system operating costs. • As an alternative, designs can be in 1.4301 stainless steel or coated splitters. • Type MKA provides a higher level of sound attenuation, particularly in the area of critical fan noise levels. • Type XKA is well suited for silencing higher frequencies (e.g. in cases of machine noise). The splitter frame is made of galvanised steel. Rectangular; square L: 500 – 1,500 mm W: 100/200/300 mm H: 300 1,800 mm Other dimensions upon request. Types MSA•XSA …… • Attenuators consist of rectangular casings with built-in splitters of Types MKA/XKA. • The connecting frame is an air duct profile with a flange of 30 mm. As an alternative, an angle frame (35 x 3 mm) is also available. The angle frame must be used in case of W or H dimensional graduation. Rectangular; square Maximum one-piece sizes available: L: 500 – 1,500 mm, W: 200 – 2,400 mm, H: 300 – 1,800 mm Casing air leakage complies with DIN EN 1751, class A Types CA•CB•CF•CS•CAK …… • Types CA and CB are made of galvanised sheet steel. The absorption material is mineral wool covered with a nonwoven glass fibre scrim and a perforated plate. Type CA is a good secondary silencers for air terminal units. Type CB is suitable for higher acoustic requirements. • Types CF und CS are made of aluminium. Type CF, a flexible design, is well suited for installation, situations with complex ductwork and/or limited space. Type CS consists of rigid aluminium and is used, for instance, as a secondary silencer for TVR-Easy. • Type CAK is made of plastic (PP) and is well suited for installation into circular ductwork carrying aggressive media. Circular 80 – 1,000 mm L: 500 – 2,000 mm Insulation thickness: CA•CB = 50/100 mm CF•CS = 25/50mm Casing air leakage complies with DIN EN 1751, Class C or B 59 … Filters Not just clean, but pure …… Clean room production of Frank Plastic AG in Waldachtal, Germany On 40 injection moulding machines in a 2,000 m2 clean room of the class 8/D, Frank Plastic AG produces high-quality, medical-technical products, such as pump units for water jet surgery. In the process, very high demands are placed on the air purity and sterility of the entire production process. To achieve the necessary air quality, TROX highefficiency terminal filters of filter grade H14 were installed as ceiling and wall diffusers. The air terminal devices have a tight fit test device and a measuring point to monitor the differential operating pressure. In addition, special pharmacy clean room diffusers provide for sterile air conditions at individual workstations and in particular manufacturing zones. Project: Frank Plastic AG, Waldachtal, Germany Filter solution: High-efficiency filters ceiling-mounted, high-efficiency filters wall-mounted, pharmacy clean room diffusers Air filtration …… The objective of air filtration is to use appropriate filter media and units to establish and maintain the level of cleanliness required for indoor spaces. Air filtration is the most important procedure in a ventilation system, particularly in the case of clean room technology. Air filters in the form of fibre filters are used in various engineering areas. In air conditioning systems they are used as so-called standard air filters for removing coarse and fine dust out of the air, thus simultaneously protecting downstream equipment and system components. In clean room technology (e.g. in the pharmaceutical, medical, and microelectronics industries, etc.), systems require an additional particulate air filter to guarantee the high clean room classes required and to act as “air equalisers” for laminar flows. 60 … The following types of filters can be differentiated: Coarse particle filters as filter pads for automatic roll filters, as cut-to-size pads, and as cardboard frame filters for cell air filters and rolls. Z-Line filters/filter cells. Bag filters made of high-quality, chemical, synthetic or glass fibre media for cell frames in the standard market sizes. Minipleat filters as high-performance filters for extracting fine dust, suspended particles and aerosols. Particulate filter cells for areas with the strictest standards for air purity and hygiene. High-performance filter panels for clean room technology. Filter units Filter units …… Air filters remove contaminants such as dust, microbes and pollen out of the air. A variety of filter housings are available for the different installation situations, as part of a centralised air handling unit or for separate air filtering, for instance, of a contaminated, closed-off area. Filters are used both in ventilation systems for office buildings and for air filtering in production processes that create a lot of dust, as well as in sensitive areas such as microbe-free operating theatres or clean rooms in the pharmaceutical and microelectronic industries. Particulate air filter Universal casings for duct installation …… • These universal casings are used as primary and secondary filter levels in air handling systems. • They can hold coarse, fine, and particulate air filters, as well as activated carbon filters. 1,700 – approx. 54,000 m3/h depending on the filter type as an individual system Duct particulate filters for highly sensitive areas …… • Duct particulate filters are used in areas with the highest air purity requirements, such as in the chemical and pharmaceutical industries or in both hospital and clean room technology. • They can be installed as individual units for varying air flow rates or as a combination of up to six adjacent filter units. High efficiency filters ceiling mounted …… • High efficiency filters ceiling mounted are used as end filters in areas with the highest requirements for air purity and hygiene such as in the medical, biological, and pharmaceutical industries, as well as in other sensitive areas. • HEPA filters can be used. • These filters can be combined with various ceiling diffusers from the TROX standard programme. 500 – 4,000 m3/h according to filter type 250 – 2,100 m3/h according to individual casing 61 … Filters Filter units | Filter media High efficiency terminal filters ceiling mounted …… • High efficiency terminal filters for ceiling installation are used as end filters and for air distribution in highly sensitive areas, such as for clean room technology. • The individual casings can be combined into ceiling sections. Pharmaceutical clean room terminal filters …… • The pharmaceutical clean room terminal filter with a highperformance filter is used for very high requirements on air purity and sterility in the pharmaceutical industry. • The air terminal device part can be folded down for easy disassembly and cleaning. 600 – 1,200 m3/h for each individual casing 240 – 800 m3/h for each individual casing Filter media …… TROX provides filter media for its filter units for every application in industrial and clean room air handling systems. Our programme includes coarse, fine, and particulate air filters and activated carbon filters in filter grades G3 G4, F5 F9, H10 H14, and U15 U17. Specially selected filter materials and the design of the filter elements guarantee fewer pressure drops and thus cost efficiency. All filters have been tested according to European standards and are available in all conventional sizes. All filter media can be disposed of in waste incineration plants, depending on the material chosen. Städtische Krankenanstalten Düsseldorf (Municipal Hospital), Düsseldorf, Germany Coarse/fine dust filters …… • Coarse filters are primarily used as prefilters to extract coarse to fine dust from ventilation systems. • Fine dust filters are used to extract fine dust in ventilation systems with high requirements. • They are available as rolls, cut-to-size filter pads, and panel filters. 62 … Filter grade: G3 – F5 Nominal air stream velocity: 0.9 – 3.1 m/s according to material Filter media Z-Line filters …… • Z-Line filters are especially suited for installation in standard cell frames from TROX for wall and duct installation, as well as for the standard sizes found on the market. • Because they can collect large quantities of dust with only few pressure drops, they have long service lives and maintenance intervals. • They stand out for their relatively low weights and small transport volumes. Bag filter inserts made of chemical, synthetic or glass fibre media …… • Bag filter inserts are used as prefilters or main filters in ventilation systems, depending on the filter type, to extract coarse and fine dust. • The stable plastic front frame ensures easy disposal. • This filter is available in the widest variety of standard market sizes. Minipleat filter inserts and cells used as fine dust and particulate filters …… • Minipleat filter inserts are used as prefilters and terminal filters in ventilation systems that require high volume flow rates and long filter lives. • The wedged shape of the minipleat filter increases the filter area and thus ensures high air flow rates with few pressure drops. Compact filters/particulate filters …… • Compact fine dust filters were developed for gas turbines and industrial use, wherever operating conditions are rough and also for ventilation and air conditioning systems. • They are designed to resist high fluctuations in pressure and well suited for pulsating volume flows. Filter grade: G4 Filter frame: stable cardboard frame Filter grades: G4; F5 – F 9 Bag filter lengths: 360 – 700 mm Filter frame: plastic or galvanised sheet steel Filter grade: F6 – F9; H10 – H14 Filter frame: plastic, galvanised sheet steel, or waterproof pulp wood. Filter grades: F6 – F9; H10 – H13 Filter frame made of sendzimised or stainless sheet steel 63 … Filters Filter media Minipleat filter panels used as fine dust and particulate filters …… • Minipleat filter panels are used as prefilters for extracting coarse and fine dust or as high-performance filters for extracting suspended particles, aerosols, toxic dusts, viruses, microbes, and the like from supply and exhaust air. Filter grades: F7, F9; H11, H13, H14 Filter frame made of aluminium, galvanised steel frame, stainless steel, or pulp wood Minipleat filter panels for clean room technology …… • Minipleat filter panels for clean room technology meet the highest requirements for air purity and sterility, particularly in sensitive areas such as the medical, pharmaceutical, and microelectronic industries. • They are installed as the terminal item in filter ceilings, clean workbenches, and high-efficiency terminal filters, in which both the highest degree of cleanliness and controlled air flow must be guaranteed. Filter grades: H14, U15, U16, U17 Filter frame made of aluminium profile Activated carbon filter cells and inserts …… • Activated carbon filters help adsorb odorous and harmful substances in gaseous form, for example, in airports, as well as hydrocarbons and traces of inorganic compounds. • They are available as panels, cells, cartridges, and inserts for installation in walls and ducts in ventilation systems. 64 … Filter frames made of steel or moisture-resistant pulp wood, plastic. 85% of the costs caused by an air filter are energy expenses incurred during operation. The acquisition, maintenance, and disposal costs only amount to about 15% of their overall costs. To lower the energy costs, TROX has developed bag filters, fine dust filters, and high-performance particulate filters in various filter grades, by means of which up to 50% of the energy costs can be saved in comparison with conventional filter media. 65 … Communication and automation systems ... and now the weather …… The new headquarters of the Deutscher Wetterdienst DWD in Offenbach, Germany Project: DWD, Offenbach, Germany Owner: Hessisches Baumanagement Architect: BLFP, Frielinghaus Architekten Specialist consultant: Alhäuser + König Ingenieurbüro GmbH HVAC-contractor: Zimmer & Hälbig GmbH Fire and smoke protection solution: TROXNETCOM AS-i with basic user software and touch panel, fire dampers, duct smoke detectors 66 … The Deutscher Wetterdienst (German Weather Service) is not only responsible for the weather forecast. It has an extensive legal commission to provide information and do research, the fulfilment of which required a new headquarters. The new building for about 900 employees consists of a three to seven story administration building with two underground stories, an underground garage, a computer centre, an auditorium, a library, and conference rooms. TROX know-how was in demand for fire and smoke protection. Complex scenarios had to be implemented successfully using the TROXNETCOM AS-i technology. In close cooperation with a planning agency, the HVAC contractor, and the supplier of the centralised building management system, a thorough, open automation solution was created, into which external systems were integrated in addition to the components, software, and services of TROX. The connection of a fire detection system and coupling with the centralised building management level rounded off the overall concept. The TROXNETCOM AS-i system with TROX fire dampers and TROX duct smoke detectors with integrated touch panel for operation and visualisation can be operated autonomously. The TROXNETCOM basic user software informs the operating personnel about the current state of the plant on the touch panel and on the building management system level. Warnings, plant faults, and automated function checks of the fire protection system are displayed and recorded. Due to the early inclusion of TROX in the consulting and project planning phases, the objective of a safe, user-friendly TROXNETCOM AS-i system solution was able to be implemented in a cost-saving manner within the available time period. Individual system design TROXNETCOM®: Custom-made solutions for controlling and monitoring ventilation components …… Modern ventilation technology such as air terminal units, decentralised ventilation systems, and safety systems like automation systems for fire protection and smoke extraction communicate and work interactively. Data can be polled and displayed from the centralised building management system. Remote querying via the Internet or by mobile phone can subject the functionality of the systems to continuous checks while simplifying maintenance. by the use of modern communications and automation systems with which systems can be changed to meet changed requirements almost at the push of a button. System safety is increased by its integration into the building management systems since malfunctions can be detected and eliminated immediately. Using the power lines for data communication purposes also eliminates the conventional wiring, reducing the fire loads in a building. Furthermore, the flexible usage required of buildings today is only achieved TROX uses two systems to accomplish this: LON technology as an open standard in building automation, and the AS-interface, an internationally standardised industrial bus system that has been approved by TÜV for use in fire protection and smoke extraction because of its high system stability and data safety (SIL 2 according to IEC/EN 61508). TROX provides its customers with custom-made solutions for the areas of fire protection, smoke extraction, flow rate control, decentralised ventilation, laboratory air regulation, and the control of adjustable air terminal devices. The features of TROXNETCOM® Advantages • Digital monitoring and control of fire dampers and smoke extraction dampers, as well as limit switch recording • Smoke detectors with general building inspectorate licence for detecting smoke in ventilation systems and operating fire dampers • TÜV-tested compliance with the highest safety standards based on EN 61508 (VDMA 24200-1) • Very easy commissioning based on the TROXNETCOM® basic user software • Integrated maintenance routines for checking the functioning of the fire protection components, including logging • Complete LONMARK®-certified LON product portfolio for fire protection • LON components for controlling analogue air terminal units and adjustable diffusers • Custom-made LON regulators for controlling and monitoring decentralised ventilation equipment • LON laboratory control systems for regulating air pressure in rooms and volume flow rates in laboratories • Integration into almost any centralised building management system • Lower wiring costs • Reduction of the fire loads • Power line technology: 24 V and 230 V lines are simultaneously used for data communications • Flexible wiring options • Easiest installation and commissioning • Components are delivered to the construction site already wired for use • High flexibility • High degree of standardisation • Highest levels of system, data and operating safety according to EN 61508 • Manufacturer independence due to our usage of an open standard (LON (ANSI CEA 709.1-4) and the AS interfaces (EN 50295, IEC 62026-2)) • Reduced maintenance costs thanks to integrated function control of the fire protection systems, including documentation 67 … Laboratory ventilation systems Futuristic laboratories with TROX technology …… The Novartis Campus in Basel, Switzerland One of the most ambitious construction projects in Switzerland is in progress at the Novartis Sankt Johann industrial complex in Basel. By 2030, a highly modern research, development, and management centre will be created for about 10,000 employees on the premises of the new Novartis Campus. First-class architects, designers, and consultants are creating openplan laboratory workstations for interdisciplinary cooperation in the individual buildings. The respective buildings on the Campus are being named after their architects. Special value is being placed on sustainability. The energy requirements of the Campus buildings should thus amount to only one-third of the normal energy consumption. In the medium term, the entire area should be supplied with energy generated without CO2. Project: Krischanitz Building, Basel, Switzerland Architect: Professor Adolf Krischanitz Specialist consultant: Kiwi Systemingenieure und Berater HVAC contractor: ATel Gebäudetechnik Fire protection: Type FKI fire dampers with angle frames, Belimo actuators, and LON integration (also ATEX) LABCONTROL: Systems for fume cupboard and room regulation in laboratories using LONWORKS® digital communication (TCU-LON II) Other products: Shut-off dampers, grilles, displacement air terminal devices, air terminal units, various swirl and ceiling diffusers, silencers, valves, multileaf dampers, and floor grilles For the numerous buildings of this gigantic project, TROX is supplying for components and systems for air handling, fire protection, and laboratory air management. In the Krischanitz, Moneo, and Taniguchi buildings, for example, TROX is providing fire protection management on the basis of TROXNETCOM and laboratory air management on the basis of LABCONTROL. The LABCONTROL control system autonomously optimises the volume flow balance within the room under consideration of need-based laboratory air extraction. This balance is adapted according to the air intake speed and the degree of opening of the protective window. System data is exchanged with the building management system via a bus network. This building management system continuously controls functional reliability and energy consumption. In this way, ambitious energy saving objectives can be achieved. Project: Moneo Building, Basel, Switzerland Architect: José Rafael Moneo Vallés Planner: Mayer Ingenieurbüro Installer: Voirol AG LABCONTROL: Systems for fume cupboard and room regulation in laboratories with analogue communication (TCU II) Other products: Fire dampers (ATEX), slot diffusers, grilles, air terminal units, disc valves, multileaf dampers, floor grilles, various displacement air terminal devices, ceiling diffusers, and combined air terminal devices © Badische Zeitung Gehry Building, Basel (CH) 68 … Individual system design LABCONTROL: Custom-made solutions for safe, energy-saving laboratory air management …… Ventilation systems in laboratory buildings must fulfil complex, strict requirements. Protecting lab personnel and reducing energy consumption to the lowest possible levels are the main objectives. The LABCONTROL SYSTEM of TROX provides custom-made solutions that comply with these standards: from controlling and monitoring individual fume cupboards or rooms, all the way to complete ventilation systems for entire laboratory buildings. In the process, all applicable standards such as DIN 1946, Part 7, and EN 14175 are observed. Both the fume cupboard controller and the supply and exhaust air controller have very short reset times and are electronically networked to each other guaranteeing an instant, continuous room pressure balance without a time delay whenever the fume cupboard is opened or closed. The features of LABCONTROL • Digital flow rate controllers for fume cupboards and room balance control based on modern communication systems such as LONWORKS® technology • Flow rate control and monitoring of fume cupboards (variable, constant, two-point) • Option for room pressure and room temperature control, as well as the regulation and monitoring of diversity factors • Option for connecting external displays for fast polling of the system status of the air terminal unit, e.g. for diagnostic purposes • Control unit variants for fume cupboard monitoring, featuring various functions • VAV controllers made of tough materials such as polypropylene or stainless steel • Removable differential pressure sensors for easy cleaning of the flow rate measurement sensor. • Air terminal units certified for potentially explosive areas • Autonomous monitoring systems for laboratory fume cupboards • Room pressure monitoring systems for displaying the current air pressure of the room with optical and acoustic alarms The LABCONTROL family of products also has electronic control variants that have been especially tailored for these demands. That is why our system solutions can be used in hospital areas or in the pharmaceutical industry to maintain both the required flow rates and the thermal room climates. Our electronic controllers use analogue and digital signals (LONWORKS®) to communicate. The efficient central recording and display of all system parameters, including fault messages, for example, also increase safety. The wide range of modification options allows you to build more flexible systems while remote accessing enables diagnosis and adjustment without high personnel and working-hour expenses. Advantages • Competent consultation and support during all the phases of a project, from the planning to the hand-over, as well as during operation • Production-accompanying service package: commissioning, system integration, maintenance, and refurbishment concepts • Easy networking to parent systems by using standardised interfaces • Greatest possible data transparency by using open systems (LONWORKS®, BACnet) • One-stop shopping ventilation system solutions, reducing the number of interfaces required • Reduced fire loads thanks to significant reductions in wiring required for the bus technology used • Support of flexible usage concepts: the systems can be easily modified to meet new standards • Rapid amortisation of investment costs thanks to reductions in operating costs • Energy savings due to optimised operation of the systems • High level of operating safety because the systems monitor themselves • Option of remote access to bus systems for diagnosis or modification purposes 69 … Advanced IT Cooling Systems Optimum cooling for computer centres …… TROX AITCS (Advanced IT Cooling Systems) develops high-density cooling solutions based on CO2 for the IT sector, thus playing an important role in the high availability of computer centres and the air conditioning of heavily thermally loaded IT workstations. Cooling with CO2 The system cooling solutions are based on carbon dioxide (CO2) as an energy transfer medium. Under ecological and safety aspects, CO2 is an almost ideal cooling agent. It is nonflammable, oilfree, and chemically inactive and has only a low ozone depletion potential. It is electrically non-conductive and presents a danger to neither the server nor the electrical lines. Evaporating CO2 is able to take up seven times the amount of heat in comparison with cold water. Both the CO2OLracTM system solution for server racks in computer centres and the CO2OLdeskTM IT workstation air conditioning solution achieve energy savings of 30 - 50% in comparison with conventional systems. Eight international awards are proof of the high performance capabilities of AITCS solutions. Defining characteristics of the technology are its maximum safety features and highest possible energy savings. AITCS solutions can be used for all commercial server racks or desk systems and are thus ideally suited to new and existing buildings and facilities. Project: ABN AMRO-Bank, London, Great Britain Specialist consultant: Norman Disney & Young Contractor: Mitie/Long & Partners Location: 250 Bishopsgate System: CO2OLrac™ server cooling solution The system installed in the computer centre of the ABN AMRO Bank consists of two water-cooled cold water sets with R134A Turbocor compressors and a system water temperature of 6°/12°C. The entire project was carried out according to TIER classification N+1. The installation of the secondary CO2 distribution system was implemented in stainless steel pipes. All 15 CO2OLrac™ rack coolers have temperature sensors, controllable fans, and a cooling capacity of 20 kW each. The total cooling capacity thus amounted to 300 kW. The rack coolers were provided as a customised solution for the bank’s 600 mm x 42 HE high racks. 70 … Blade server cooling TM CO OLrac blade server cooling 2 …… Intensive cooling for blade servers The CO2OLracTM cooling system works with CO2 as the heat transfer medium. By means of a perforated front panel door, inside air is conducted through the blade servers through several fans on the back side of the rack. In the process, the air takes up the heat of the blade servers and cools them. The heated air is then cooled down to room temperature again in the heat exchangers, which are operated using CO2. The heavily thermally loaded rack thus does not have to be in the same room as the existing air conditioning system and does not require a cooling/heating path constellation. Thanks to the high cooling capacity of 30 kW and more per rack, the highest possible packing density of blade servers in the server racks can be achieved. With respect to the use of conventional air conditioning, using the high-performance energy transfer medium saves more than 50% space in the technical infrastructure area of a data centre, as the number of server racks is reduced and a clearly higher room capacity is achieved. Along with this enormous cooling capacity, energy savings of more than 50% can be generated in comparison with conventional systems based on cold water and other cooling agents. CO2OLracTM can be used for all commercial server racks and is ideally suited for both new and existing computer centres. Advantages of the CO2OLrac™ system: 22° C +/- - High cooling capacity of more than 30 kW per rack - Highest possible packing density of the server racks - Reduction of the technical infrastructure areas to up to 50% - 50% energy savings in comparison with conventional cooling - Can be used for all conventional server racks - Highest security due to a CO2 detection system - For new and existing computer centres 24° C +/- 35/40° C 22° C 22° C Normal operation 24° C +/Open rack “e-chain” system, flexible four-wireconnection, N+1 71 … Advanced IT cooling systems Dealer desk cooling TM CO OLdesk dealer desk cooling 2 …… Intensive cooling for dealer desks With the development of CO2OLdeskTM, TROX AITCS offers intensive cooling for dealer desks. This high-performance desk air conditioning system was developed to fulfil the requirements of investment banks for the equipment of high-performance workstations. Function: The heat loads arising in the dealer desks due to computers and other heat sources are directly dissipated via the CO2OLdeskTM system. The cooling creates a microclimate that is confined to the individual workstation. The concept guarantees an optimum adaptation of CO2OLdesk™ to the computer heat load to be removed. The self-regulating system lets users set up their computer tower on either side of the workstation. The high-density cooling system uses CO2 as a heat transfer medium. For the installed data processing technology it presents no potential dangers in comparison with water-based cooling and enables energy savings from 10 to 30% due to the low power consumption. CO2 detection systems continuously monitor the CO2 concentration in the room and guarantee an early warning using acoustic and visual signals in case CO2 escapes. On the whole, CO2OLdesk™ comes off well in system comparisons.The system offers great cooling capacity in the dealer halls and optimum workstation comfort without impairment of the air conditioning. Advantages of the CO2OLdesk™ system: - 72 … Heat loads are dissipated directly at the source High specific cooling capacity CO2OLdesk™ can be used for all commercial desk systems For new and existing dealer desks Space-saving integration into false floors due to low construction height Up to 30% energy savings in comparison with alternatives operated with cold water Versatile, individual areas of application Dealer desk with CO2OLdesk™ (recessed installation) Plant description CO …… 2 plant options: To complete the high density system, a CO2 plant option is specified: CO2OLpacTM When an existing building has sufficient chilled water to cool the high density server load, a CO2OLpac™ solution is specified. The server heat within the vapourised CO2 is rejected via the CO2OLpac™ heat exchanger into the existing chilled water system. CO2OLpac™ units are available from 100 kW to 600 kW. CO2OLpacTM CO2OLairpacTM Where the building’s cooling infrastructure is to be enhanced to satisfy an increased heat load, either the CO2OLairpac™ or CO2OLwaterpac™ are specified. Both chillers provide a packaged plant solution to compliment a dedicated high density server cooling system. For the CO2OLairpac™, aircooled R134a chiller with integral CO2OLpac™, modules are available from 300kW to 750kW capacities. CO2OLairpacTM CO2OLwaterpacTM The CO2OLwaterpac™ solution is a water-cooled R134a chiller with integrated CO2OLpac™ module designed to suit cooling tower systems. This compact unit is available in modules from 300 kW to 900 kW. CO2OLwaterpacTM 73 … Insufficient cooling in computer centres often leads to server failures. For this reason, the cooling of these devices is vital and accordingly consumes many resources. In 2006, the U.S. Environmental Protection Agency has calculated that the servers and memory systems and equipment used to cool these systems in computer centres on American soil in the United States cost 61 billion kilowatt hours of electricity. This is twice as much as in 2000 and makes up 1.5% of the national power consumption. If the power consumption of the computer centres continues to rise at the same rate as at the beginning of the century, it will reach about 100 kilowatt hours by 2011 according to the EPA. For ecological and economical reasons, energy-saving innovations are thus even more in demand today than ever before. 74 … 75 … Headquarters in Germany TROX GmbH Heinrich-Trox-Platz 47504 Neukirchen-Vluyn, Germany Phone +49 (0) 28 45 / 2 02-0 Fax +49 (0) 28 45 / 2 02-2 www.troxtechnik.com [email protected] International Center Air Conditioning and Acoustics, Neukirchen-Vluyn, Germany TROX Deutschland GmbH branches North branch East branch 1 Hanover office 2Berlin office Bothfelder Straße 23 30916 Isernhagen, Germany Phone +49 (0) 5 11 / 61 00 34 Fax Central branch South branch Zur Wetterwarte 50, 4Frankfurt office 5Munich office Rotherstraße 18 Haus 337/C01109 Dresden, Kaiserleistraße 43 Liebigstraße 2 10245 Berlin, Germany Germany 63067 Offenbach am Main, 85301 Schweitenkirchen, Phone +49 (0) 30 / 2 61 80 51 Phone +49(0)3 51 /8890911 +49 (0) 5 11 / 61 00 35 Fax +49 (0) 30 / 2 62 90 78 +49 (0) 5 11 / 61 98 20 [email protected] Fax Germany Germany +49(0)3 51 /8890912 Phone +49 (0) 69 / 9 85 56-0 Phone +49 (0) 84 44 / 9 25-0 +49 (0) 3 51 / 8 89 09 10 Fax +49 (0) 69 / 9 85 56-111 Fax +49 (0) 84 44 / 9 25-10 [email protected] [email protected] [email protected] [email protected] Southwest branch West branch 6Stuttgart office 7Neukirchen-Vluyn office Hohentwielstraße 28 Heinrich-Trox-Platz 70199 Stuttgart, Germany 47504 Neukirchen-Vluyn, Phone +49 (0) 7 11 / 6 48 62-0 Germany Fax +49 (0) 7 11 / 6 48 62-20 Phone +49 (0) 28 45 / 202-611 [email protected] Fax +49 (0) 28 45 / 202-612 [email protected] 76 … 3Dresden office Subsidiaries and sales offices Argentina Denmark India Poland Spain TROX Argentina S.A. TROX Danmark A/S TROX INDIA PRIVATE LIMITED TROX Austria GmbH TROX España, S.A. Australia Germany Italy Romania South Africa TROX Australia Pty Ltd TROX Deutschland GmbH FSL GmbH & Co. KG TROX Italia S.p.A. TROX Austria GmbH TROX South Africa (Pty) Ltd Croatia Russia Czech Republic TROX Austria GmbH OOO TROX RUS TROX Austria GmbH Malaysia Sweden Hungary TROX Malaysia Sdn. Bhd. TROX Sverige AB TROX Austria GmbH Norway Switzerland USA TROX Auranor Norge AS TROX HESCO Schweiz AG TROX USA, Inc. China Austria Serbia United Arab Emirates TROX Air Conditioning Components (Suzhou) Co., Ltd TROX Austria GmbH TROX Austria GmbH TROX Middle East (LLC) Belgium S.A. TROX Belgium N.V. France TROX France Sarl Brazil TROX do Brasil Ltda. Great Britain TROX UK Ltd.TROX AITCS Ltd. Bulgaria TROX Austria GmbH Hong Kong TROX Hong Kong Ltd Foreign representatives Abu Dhabi Indonesia Lithuania Saudi Arabia Thailand Bosnia-Herzegovina Iran Morocco Slovak Republic Turkey Chile Ireland Netherlands Slovenia Ukraine Cypres Israel New Zealand Sweden Uruguay Egypt Jordan Oman Taiwan Venezuela Finland Korea Pakistan Zimbabwe Vietnam Greece Latvia Philippines Iceland Lebanon Portugal 77 … TROX GmbH Heinrich-Trox-Platz D-47504 Neukirchen-Vluyn Telephone +49 (0) 2845 202-0 Telefax +49 (0) 2845 202-265 Internet www.troxtechnik.com e-mail [email protected]