CSRN-XHE 362-904
Transcription
CSRN-XHE 362-904
PACKAGED 362 - 904 ® CSRN-XHE 362-904 HIGH EFFICIENCY "ROOF TOP" AIR COOLED HEAT PUMP • REDUCED ENERGY CONSUMPTION • COMPACT DIMENSIONS • ENERGY RECOVERY STANDARD (CONSTRUCTION CONFIGURATION C) Cooling Heating [kW] [kW] 362 119 116 402 130 130 452 140 142 464 159 155 524 177 174 604 205 200 704 228 225 804 275 276 904 301 302 Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. The CSRN-XHE series of autonomous roof-top air conditioners, air-air heat pump, is a turning point in this type of unit. Intended for air conditioning of large surface areas with average traffic, such as supermarkets, shopping malls, trade fair pavilions, airports, stations, and manufacturing areas), it contains the very latest technology, featuring: VERSATILITY OF USE The wide range of versions, options and accessories allow unique integration and flexibility of choice, regardless of the intended use and the external climate. EASE OF POSITIONING AND INSTALLATION The units are exceptionally compact, perfect for positioning on especially crowded roofs. Attention to client needs and care for details has led to the creation of a machine than can be quickly installed and immediately commissioned. REDUCED OPERATING COSTS These are now guaranteed thanks to the high efficiency of the innovative refrigeration circuit for operation at partial load, of the freecooling and of the heat recovery, standard on all models equipped with air expulsion, of the optional electrostatic air filters. CERTIFIED QUALITY SYSTEM UNI EN ISO 9001:2008 BT08A006GB-04 Size REPLACE: BT08A006GB-02 CSRN-XHE 362 - 904 (R-410A) PACKAGED 362 - 904 GENERAL DESCRIPTION MAIN FUNCTIONS AND APPLICATIONS The CSRN-XHE autonomous roof-top air conditioners are highefficiency air-air heat pumps with completely automatic operation. Based on user settings, the unit provides complete air treatment through ventilation, filtering, cooling, possible heating, complete or partial addition of fresh air, possibility to control humidity. These machines are extremely compact and resistant to atmospheric agents, suitable for outdoor installation on a flat roof, on a platform or on the ground. The distribution of treated air (to be handled by the client) takes place via supply and return ducts and suitable distribution devices such as air outlets or nozzles. They are therefore perfect for air conditioning of large-volume rooms with average traffic, such as large commercial surfaces, trade fair pavilions, airports, stations, and production areas. VERSATILITY OF USE APPLICATIONS VERSATILE POSITIONING: ON FLAT ROOF, ON PLATFORM ON GROUND The wide range of models and the possibility to choose the constructive configurations make it possible to select the product that is best suited to the needs of each installation and to integrate the unit into various architectonic contexts. The selection of accessories completes the possibility to customize the product according to the needs of the client. EXTREME COMPACTNESS The original layout of the sections that make up the machine substantially reduces its footprint, making it easier to position and leaving more space available for parking, additional equipment rooms or other uses. This also reduces the time required for the positioning of the ducts on the various sides of the unit, since its great compactness allows its complete rotation (which is very difficult with traditional units with in-line extension). REDUCTION OF CONSUMPTION AND OPERATING COSTS BT08A006GB-03 The roof-top units of the XHE series were created with the objective of always operating at maximum energy savings through an extremely intelligent and advanced control of power provided only when it is needed, especially during frequent conditions of operation at partial load. The use of the free-cooling device and the adoption of thermodynamic recovery on the expelled air make it possible to further reduce operating costs. Since ventilation represents one of the greatest factors of energy consumption, special attention has been given to the efficiency of the ventilation system through careful selection of components and limitations of internal pressure drops. The limitation of the emissions of carbon dioxide and respect for the environment are guiding thoughts of Clivet which, through the implementation of modern technical solutions, pursues the reduction of energy consumption. EASY MAINTENANCE The entire series is designed with highly reliable industrial components that are easily accessible and available if maintenance is required. It is also equipped with self-diagnosis and safety devices that ensure its proper operation while at the same time protecting users. 2 APPLICATION EXAMPLES PACKAGED 362 - 904 GENERAL DESCRIPTION OF CONFIGURATIONS AVAILABLE IN CATALOGUE The CSRN-XHE range of air conditioners can be extensively personalised and is available in two configurations. Both configurations are capable of conditioning air flow rates with mixtures of return air and fresh air. The machines are extremely versatile, since they have three air flow modes: high, standard, and low. The units can be further personalized with the choice of accessories (optional) that are specially designed to meet various application needs. CB - MANUFACTURER VERSION B WITH MIXING, RECIRCULATION AND FRESH AIR CHAMBER The standard constructional configuration, called version B, allows control of supply and return air flow and the intake of fresh air for required refreshing by means of a manually operated shutter. The version with optional setups is equipped with shutters with a servo-motor for constant adjustment of the refresh air mixture: - operation with a fixed percentage of refresh air with opening or closing of the shutter by means of an actuator (ON-OFF) which intervenes when ventilation is active (optional) - operation with variable percentage of refresh air with opening and closing of the shutters by means of modulating actuators driven by the signal of the air quality probe (optional) - operation with variable percentage of refresh air with opening and closing of the shutters by means of modulating actuators, which intervene when the fresh air conditions are such that they allow lowering of internal thermal loads simply by placing primary air in the room (free-cooling B) (optional). CONFIGURATION B WITH FREE COOLING VERSION B CONFIGURATION B STANDARD OR WITH SHUTTER ON-OFF OR WITH MODULATING SHUTTER SUPPLY + - RETURN 70% SUPPLY 30% + - 70% RETURN 30% MAN AUT FRESH AIR FRESH AIR CC - MANUFACTURER VERSION C WITH MIXING, EXPULSION, HEAT RECOVERY AND FREE COOLING BT08A006GB-03 When the machine is in optional constructive configuration (called version C), it allows automatic management of the supply and return air flows, and the intake of fresh air for required refreshing. In addition, it is capable of expelling the return air from the served room by means of dedicated fans and to recover the energy of the expelled air. The automatic adjustment of the shutters allows operation of the unit: - with full recirculation - with a mixture of re-circulation air and refresh air - with all refresh air and total expulsion of return air (total free-cooling). CONFIGURATION C WITH MODULATING SHUTTERS EXHAUST AIR - + 30% SUPPLY + - 70% RETURN 30% FRESH AIR 3 PACKAGED 362 - 904 CONFIGURATION CODE (1) CSRN - XHE C (2) 452 ( 3) M B (4) 200 M (5) R --- 100 --- R C (1) CONSTRUCTIONAL CONFIGURATION (5) INTAKE STATIC PRESSURE VALUE recirculated/outside air mixing box (B) free cooling version with extract/recirculated/fresh air intake box (C) (6) AIR FLOW Standard (S) Standard air flow (SM) Reduced air flow (RM) Air flow high (HM) (3) OUTLET STATIC PRESSURE VALUE (7) INTAKE AIR FLOW (4) RETURN Standard air flow (SR) Reduced air flow (RR) Air flow high (HR) (2) SUPPLY Standard (S) (6) SM (7) SR SM SR RM RR HM HR UPDATED ELECTRONIC CONTROL The operation of the unit is fully automatic thanks to the Clivet Talk electronic adjustment system. This is a modular device, of automatic origins, with high speed and reliability and control logic specifically designed for this type of product. The user interface is easy to use. This allows better use of available resources, extending the life cycle of the components and thus reducing maintenance costs. With the micro-processor keypad, it is possible to perform daily/weekly programming of the set-point, as well as start-up or shutdown of the machine. The unit can also be connected to supervision systems using clean contacts or by serial with the standards of communication most commonly available on the market. CONTROL LOGICS IN THE EVENT OF ALARM SIGNAL Machine logics BT08A006GB-03 (1)Complete shutdown (2)Room kept de-pressurized (3)Room kept pressurized Vers. B with freecooling option Description Version B standard Version C Supply fan Off Off Off Return fan - - Off Fresh air Shutter Open Closed Closed Discharge camper - - Closed Recirculation shutter - Closed Closed Supply fan - - Off Return fan - - On Fresh air Shutter - - Closed Discharge camper - - Open Recirculation shutter - - Closed Supply fan On On On Off Return fan - - Fresh air Shutter Open Open Open Discharge camper - - Closed Recirculation shutter - Closed Closed The machine logic manages the signal from a fire detection unit, implementing one of the actions shown in the table which can be set as a parameter. If there is an alarm signal and according to the set logic, the compressors are always shut off. The roof-top units may not be used as smoke extractors. 4 PACKAGED 362 - 904 ELECTRONIC EXPANSION VALVE The electronic expansion valve is an essential component of the refrigerant circuit. It offers a number of advantages as compared to the traditional thermostatic valve. These include: - reduction of overheating temperature (greater efficiency of refrigerant circuit) - improved compressor working conditions (COP optimized) - reduction of output temperature of the compressor - reduction of pressure at condenser (less energy absorbed by compressors) - adaptation to all load conditions and transitories without causing swinging at partial loads All this aids in increasing the efficiency of the load for any thermal load condition and to extend the life cycle. LOW EFFICIENCY DANGER OF BREAKAGE OVERHEATING HIGH EFFICIENCY OPTIMAL OPERATION LOW EFFICIENCY P = Provided Power Variation EEV= Electronic valve TEV = Thermostatic valve DANGER OF BREAKAGE PRESENCE OF LIQUID FC - THERMAL FREE COOLING (CONSTRUCTION CONFIGURATION C) BT08A006GB-03 As soon as external conditions allow it, the unit is capable of automatically activating free-cooling mode, which, by keeping the compressors off and drawing in suitably filtered fresh air, cools the served room. The fresh air flow can be varied based on actual needs. This operating mode is especially useful in spring and autumn or with high ambient loads. It allows substantial reduction of the unit's energy consumption and wear of the compressors. OUTSIDE TEMPERATURE PROBE The measurement of the temperature of outside air is an essential parameter of heat adjustment. It takes place via a probe located in a special compartment that connects the external environment and the return duct (always in negative pressure). Clivet has chosen this solution to ensure correct measurement of temperature since the probe is constantly in contact with a minimum flow of air. On request, the temperature probe can be integrated with the optional humidity probe). INTAKE DUCT FRESH AIR OUTSIDE TEMPERATURE PROBE 5 PACKAGED 362 - 904 VERY HIGH EFFICIENCY AT PARTIAL LOAD In air conditioning projects, the choice of the unit is made based on the maximum load of the room to be served. In practice, over the course of the year these operating conditions are limited to short periods of time, whereas operation at partial loads is the actual normal operating condition. The need to adapt the power provided to the load requested becomes essential in limiting energy consumption. This is why we have decided to couple two scroll compressors of different power on a single refrigeration circuit, thus obtaining very high efficiency. The electronic control that the machine is equipped with divides compressor operation into three steps of power (1/3, 2/3, 3/3). This limits the oscillation of the air temperature, and provides perfect adaptation to partial load, offering substantial energy savings. %% WORKING Tempo diTIME lavoro FOR Per90% il 90OF % THE del TIME, LOAD IS tempo il carico LESS THAN 80% è 8 7 6 EER 5 4 inferiore al80% 100% 90% 80% FOR Per70% il 70OF % THE del TIME, LOAD IS tempo il carico è LESS THAN 50% inferiore al50% 70% 60% 50% 40% 3 30% 2 20% 1 10% 0 0% <20% (1) (2) (1) <30% (3) (2) <40% <50% <60% (3) <70% <80% <90% <100% Carico termico %% THERMAL LOAD (1) WITH THE SMALL COMPRESSOR 6.4 =TAGLIA EER = 7.4 (1)OPERATION FUNZIONAMENTO CON SOLO COMPRESSORE INFERIORE 6.4 = EER = 7.4 (2) WITH THE BIGSOLO COMPRESSOR 4.9 = EER = 5.9 SUPERIORE 4.9 = EER = 5.9 (2)OPERATION FUNZIONAMENTO CON COMPRESSORE TAGLIA (3) OPERATION WITH BOTH COMPRESSORS 3.7 = EER = 4.8 (3) FUNZIONAMENTO CON ENTRAMBI I COMPRESSORI 3.7 = EER = 4.8 APPROXIMATE VALUES VALORI INDICATIVI SELF-ADAPTABILITY Thanks to the automatic adjustment of the operating parameters based on the system load conditions, the unit is capable of optimizing its own efficiency, reducing the resulting consumption and extending the life-cycle of the components. The temperature range to be maintained in the room can be set by the user (manual set-point) or managed by the machine logic (automatic set-point). When AUTOMATIC,mode is set, the working set-points are calculated automatically and dynamically by the thermal control device based on the outside temperature and other parameters set during commissioning of the machine, thus avoiding thermal shock between the treated room and the exterior. BT08A006GB-03 COOLING SET POINT AD DE E ON Z ZONE DEAD HEATING SET POINT EXTERNAL AIR TEMPERATURE 6 THE GRAPH SHOWS THE TREND OF THE CURVES OF THE HOT SET POINT (BOTTOM LINE) AND OF THE COLD SET POINT (UPPER LINE) BASED ON THE OUTSIDE TEMPERATURE. THE HIGHLIGHTED TEMPERATURE VALUES ARE THOSE SET AS DEFAULT, BUT THEY MAY BE CHANGED ACCORDING TO CLIENT NEEDS. PACKAGED 362 - 904 DEMAND LIMIT [kW] AVAILABLE POWER The Demand Limit function is a logic that controls the machine's resources dedicated to limiting the input power from the electrical mains (for example when there are special agreements between the user and the operator of the electrical mains) or to selecting the thermal resources to be used based on special needs of the client. The Demand Limit device can control and manage the available steps of thermal power by means of the receipt of an external analogue signal, 0-10V/4-20mA. The control logic does not act on the ventilation which is therefore always ensured. The greater the input signal to the Demand Limit, the less the thermal power available for the system. In the extreme condition of pilot signal at 100%, the system can also shut off the last power step. AS THE DEMAND LIMIT SIGNAL INCREASES, THE POWER STEPS ARE GRADUALLY DISABLED. WHEN THE SIGNAL IS AT 100%, ALL AVAILABLE RESOURCES ARE DISABLED. AUXILIARY ELECTRIC HEATING ELEMENTS AUXILIARY ELECTRIC HEATING ELEMENTS 6 0 2 4 6 8 10 [V] SIGNAL 0-10V DC SFSTRV - FAN BREAKAWAY STARTING CURRENT REDUCING DEVICE. A device which allows the fans to start up gradually and accelerate steadily until the rated speed is reached. This electronic device is able to decrease the starting torque of the motor, reducing the absorbed current on start-up, at the same time protecting the motor and the transmission members (belts and bearings) from heavy stresses, thus guaranteeing an extended life for the components. During shut-off, the device allows the speed to be reduced gradually. T BT08A006GB-03 nominal operating point THE BROKEN LINE INDICATES THE MOTOR TORQUE AS SPEED INCREASES THE SOLID LINE INDICATES THE MOTOR TORQUE AS SPEED INCREASES WITH SOFT STARTER RPM I nominal operating point RPM THE BROKEN LINE INDICATES THE NORMAL CURRENT ABSORPTION ON INCREASE OF THE FAN SPEED. THE SOLID LINE SHOWS THE PLOT OF THE CURRENT ON INCREASE OF FAN SPEED WITH SOFT STARTER. 7 PACKAGED 362 - 904 NEW GENERATION OF AXIAL FANS FOR THE EXTERNAL SECTION The need for continuous improvement in machine performance has led to collaboration with specialized European laboratories for the development of more efficient axial fans. The result of this research has made it possible to develop an innovative winglet-type profile at the end of the blade. The adoption of the new profiles has made it possible to obtain substantial results in noise limitation, with an average reduction of 6 dB(A), and energy savings, with a reduction in consumption of 10%. TRADITIONAL FAN FAN WITH WINGLETS DEVICE TO REDUCE CONSUMPTION OF FANS OF THE EXTERNAL SECTION The device makes it possible to control the external axial fans, adjusting their speed of rotation based on the condensation pressure. When fresh air temperature is low, a minimum air flow rate is required to hold down the condensation pressure. Therefore, at low fresh air temperatures, fan rotation speed is reduced, resulting in reduced energy consumption (low temperature device). In heat pump mode, this device reduces the speed of rotation of the fans when external air temperatures are high (high temperature device). BT08A006GB-03 ICE PROTECTION SYSTEM ICE PROTECTION SYSTEM is a special measure for the refrigeration circuit that reduces the risk of the formation of ice at the base of the external coil. A liquid undercooling circuit maintains the temperature of the lower part of the coil, preventing the formation of a block of ice and avoiding risk of breakage due to freezing. SMART MANAGEMENT OF DEFROSTS During operation in heat-pump mode, the defrost cycles are managed with an advanced, predictive logic that reduces both frequency and duration. The innovative control system makes it possible to activate defrost cycles and to adjust their duration based on actual needs, by measuring not only the outside temperature but also the gradient of evaporation pressure. As a result, overall performance of the machine is improved and there is a reduction in the negative effect that defrost cycles have on supply air temperatures. 8 PACKAGED 362 - 904 FILTRATION Standard units are standard equipped with a suitable filtering section composed of pleated filters, class G4, with an ample surface. They are easily accessible for periodic maintenance. PANELLING The need to improve access to the internal parts of the machine for the ordinary maintenance and at the same time the need to give structural stiffness and increase thermal insulation has brought to the adoption of "sandwich" type panels on all units. The roof and the structure of the air treatment area are made with such panels with dual steel walls with polyurethain foam and feature seal gaskets alongside the ledge. The panels are hinged and feature handles and closures wi t h adjustable clamping. RE1 - ENERGY RECOVERY OF EXPELLED AIR (VERSION C) BT08A006GB-03 The energy contained in the expelled air is recovered by forcing the air flow to pass through the external packaged finned heat exchanger. This makes it possible to reduce the electrical energy absorbed by the compressors, to increase the overall efficiency of the unit and to extend its operating limits. This thermodynamic recovery system does not increase electrical energy consumption for ventilation, as instead happens for recovery with crossed or rotating flows. Greater use of electricity, caused by the enormous pressure drops on the air side in recovery systems with crossed or rotating flows, often nullifies the amount of energy recovered and even exceeds it in some cases. 9 PACKAGED 362 - 904 AIR FLOW: STANDARD GENERAL TECHNICAL SPECIFICATIONS Size 362 402 452 464 524 604 704 804 904 COOLING Cooling capacity Sensible capacity Compressor power input EER HEATING 1 1 1 1 kW kW kW 118,6 84,7 27,2 4,36 129,7 93 31,6 4,11 139,6 97,7 36,4 3,84 158,7 115,6 34,8 4,56 177,4 127,6 42,3 4,19 205,2 150,8 47,5 4,32 227,8 165,5 57,1 3,99 275,2 204,4 60,4 4,56 300,6 220,2 69,5 4,32 Heat output Compressor power input COP COMPRESSOR 2 2 2 kW kW 116,1 21,8 5,32 130,3 25,4 5,12 142 28,7 4,95 154,8 28,3 5,47 173,5 33,8 5,14 200,4 37,2 5,38 224,5 43,9 5,12 275,5 49,2 5,6 302,3 55,5 5,45 Type of compressors No. of Compressors Std Capacity control steps Refrigerant circuits AIR HANDLING SECTION FANS (OUTLET) 3 Nr Nr Nr Scroll 2 3 1 Scroll 2 3 1 Scroll 2 3 1 Scroll 4 6 2 Scroll 4 6 2 Scroll 4 4 2 Scroll 4 6 2 Scroll 4 6 2 Scroll 4 6 2 Type of fans Number of fans Number of impellers Air flow Installed unit power Max outside static pressure Max outside static pressure FANS (RETURN) 4 Nr Nr l/s kW Pa Pa CFG 1 2 5555 7,5 300 570 CFG 1 2 6111 7,5 210 570 CFG 1 2 6666 9 210 570 CFG 1 2 8056 9 240 570 CFG 1 2 9028 11 210 570 CFG 1 2 10000 15 330 510 CFG 1 2 11111 18,5 300 570 CFG 1 2 12500 18,5 330 570 CFG 1 2 13889 22 270 570 Type of fans Number of fans Air flow Installed unit power Max outside static pressure Max outside static pressure EXTERNAL SECTION FANS 7 Nr l/s kW Pa Pa CFG 1 4444 3 210 450 CFG 1 4888 3 120 450 CFG 1 5333 4 120 450 CFG 1 6444 4 150 420 CFG 1 7222 5,5 180 420 CFG 1 8000 7,5 240 450 CFG 1 8889 7,5 120 450 CFG 1 10000 7,5 120 450 CFG 1 11111 11 210 450 Type of fans Number of fans Fan diameter Fan RPM Standard air flow Installed unit power POWER SUPPLY 10 Nr mm rpm l/s kW AX 2 800 880 11528 2 AX 2 800 880 11528 2 AX 2 800 880 11528 2 AX 4 800 880 23585 2 AX 4 800 880 23585 2 AX 4 800 880 23585 2 AX 4 800 880 23585 2 AX 6 800 880 33410 2 AX 6 800 880 33410 2 V 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 Standard power supply 5 6 8 9 BT08A006GB-03 Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) (1) Ambient temperature 27°C/19.5 WB external exchanger air intake 35°C EER referred only to compressors (2) ambient temperature 20°C DB. Outside temperature 7°C DB/6 WB COP referred only to compressors (3) SCROLL = scroll compressor (4) CFG = centrifugal fan (5) with standard electric motors (6) with uprated electric motors (7) Constructional configuration C CFG = centrifugal fan (8) with standard electric motors (9) with uprated electric motors (10) AX = axial-flow fan 10 PACKAGED 362 - 904 CONSTRUCTIONAL CONFIGURATION: MIXING BOX FOR RECYCLE /FRESH AIR (B) ELECTRICAL DATA Size 362 402 452 464 524 604 704 804 904 36,5 30,6 4,1 n.d. 75,8 44,9 30,6 4,1 n.d. 84,2 44,9 36,5 4,1 n.d. 90,1 30,6 15,2 30,6 15,2 4,1 n.d. 108,5 30,6 22,6 30,6 22,6 4,1 n.d. 123,3 30,6 30,6 30,6 30,6 4,1 n.d. 139,3 36,5 30,6 36,5 30,6 4,1 n.d. 151,1 44,9 30,6 44,9 30,6 4,1 n.d. 176,1 44,9 36,5 44,9 36,5 4,1 n.d. 187,9 L.R.A. - Compressor 1 A 225 L.R.A. - Compressor 2 A 173 L.R.A. - Compressor 3 A L.R.A. - Compressor 4 A F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION 272 173 - 272 225 - 173 95 173 95 173 118 173 118 173 173 173 173 225 173 225 173 272 173 272 173 272 225 272 225 27,3 17 1,9 n.d. 48,4 27,3 22,6 1,9 n.d. 54 17 8,9 17 8,9 1,9 n.d. 59,7 17 13,2 17 13,2 1,9 n.d. 68,3 17 17 17 17 1,9 n.d. 75,9 22,6 17 22,6 17 1,9 n.d. 87,1 27,3 16,9 27,3 16,9 1,9 n.d. 100,3 27,3 22,6 27,3 22,6 1,9 n.d. 111,5 F.L.A. - FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS F.L.A. - Compressor 1 F.L.A. - Compressor 2 F.L.A. - Compressor 3 F.L.A. - Compressor 4 F.L.A. - Single External Fan F.L.A. - Single supply fan F.L.A. - Total L.R.A. LOCKED ROTOR AMPERES F.L.I. - Compressor 1 F.L.I. - Compressor 2 F.L.I. - Compressor 3 F.L.I. - Compressor 4 F.L.I. - Single External Fan F.L.I. - Single supply fan F.L.I. - Total 1 2 3 4 A A A A A A A kW kW kW kW kW kW kW 22,6 17 1,9 n.d. 43,7 power supply: 400/3/50 Hz +/-6% voltage unbalance: max 2 % Values not including accessories (1) n.d. = not defined The input of the fan motors is shown in the performance tables of the fans The installed motor must be determined taking into consideration the air flow rate and the usable static pressure (2) value including all standard components of the unit control circuit included This data does not take into consideration the motors of the zone treatment fans nor the accessories to obtain the overall F.L.A. value, add the total F.L.A. value to that of any accessories (see electrical data of accessories) and that of the motors of the treatment area fans (see table of fan performance) (3) n.d. = not defined The input of the fan motors is shown in the performance tables of the fans The installed motor must be determined taking into consideration the air flow rate and the usable static pressure (4) value including all standard components of the unit control circuit included This data does not take into consideration the motors of the zone treatment fans nor the accessories to obtain the overall F.L.I. value, add the total F.L.I. value to that of any accessories (see electrical data of accessories) and that of the motors of the treatment area fans (see table of fan performance) CONSTRUCTIONAL CONFIGURATION: FREE COOLING VERSION WITH EXTRACT/RECIRCULATED/FRESH AIR INTAKE BOX (C) ELECTRICAL DATA Size 362 402 452 464 524 604 704 804 904 36,5 30,6 4,1 n.d. n.d. 75,8 44,9 30,6 4,1 n.d. n.d. 84,2 44,9 36,5 4,1 n.d. n.d. 90,1 30,6 15,2 30,6 15,2 4,1 n.d. n.d. 108,5 30,6 22,6 30,6 22,6 4,1 n.d. n.d. 123,3 30,6 30,6 30,6 30,6 4,1 n.d. n.d. 139,3 36,5 30,6 36,5 30,6 4,1 n.d. n.d. 151,1 44,9 30,6 44,9 30,6 4,1 n.d. n.d. 176,1 44,9 36,5 44,9 36,5 4,1 n.d. n.d. 187,9 L.R.A. - Compressor 1 A 225 L.R.A. - Compressor 2 A 173 L.R.A. - Compressor 3 A L.R.A. - Compressor 4 A F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION 272 173 - 272 225 - 173 95 173 95 173 118 173 118 173 173 173 173 225 173 225 173 272 173 272 173 272 225 272 225 27,3 17 1,9 n.d. n.d. 48,4 27,3 22,6 1,9 n.d. n.d. 54 17 8,9 17 8,9 1,9 n.d. n.d. 59,7 17 13,2 17 13,2 1,9 n.d. n.d. 68,3 17 17 17 17 1,9 n.d. n.d. 75,9 22,6 17 22,6 17 1,9 n.d. n.d. 87,1 27,3 16,9 27,3 16,9 1,9 n.d. n.d. 100,3 27,3 22,6 27,3 22,6 1,9 n.d. n.d. 111,5 F.L.A. - Compressor 1 F.L.A. - Compressor 2 F.L.A. - Compressor 3 F.L.A. - Compressor 4 F.L.A. - Single External Fan F.L.A. - Single supply fan F.L.A. - Single Inlet fan F.L.A. - Total L.R.A. LOCKED ROTOR AMPERES F.L.I. - Compressor 1 F.L.I. - Compressor 2 F.L.I. - Compressor 3 F.L.I. - Compressor 4 F.L.I. - Single External Fan F.L.I. - Single supply fan F.L.I. - Single Inlet fan F.L.I. - Total 1 1 2 3 3 4 A A A A A A A A kW kW kW kW kW kW kW kW 22,6 17 1,9 n.d. n.d. 43,7 BT08A006GB-03 F.L.A. - FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS power supply: 400/3/50 Hz +/-6% voltage unbalance: max 2 % Values not including accessories (1) n.d. = not defined The input of the fan motors is shown in the performance tables of the fans The installed motor must be determined taking into consideration the air flow rate and the usable static pressure (2) value including all standard components of the unit control circuit included This data does not take into consideration the motors of the zone treatment fans nor the accessories to obtain the overall F.L.A. value, add the total F.L.A. value to that of any accessories (see electrical data of accessories) and that of the motors of the treatment area fans (see table of fan performance) (3) n.d. = not defined The input of the fan motors is shown in the performance tables of the fans The installed motor must be determined taking into consideration the air flow rate and the usable static pressure (4) value including all standard components of the unit control circuit included This data does not take into consideration the motors of the zone treatment fans nor the accessories to obtain the overall F.L.I. value, add the total F.L.I. value to that of any accessories (see electrical data of accessories) and that of the motors of the treatment area fans (see table of fan performance) 11 PACKAGED 362 - 904 ELECTRICAL INPUT OF OPTIONAL COMPONENTS To obtain the electrical input of the unit including accessories, add the standard data in Electrical Data table to those for the selected accessories. SIZE F.L.A. FULL LOAD CURRENT F.L.A. EH20 - 24 kW electric heaters F.L.A. EH24 - 36 kW electric heaters F.L.A. EH28 - 48 kW electric heaters F.L.A. EH72 - 72 kW electric heaters F.L.A. EH33 - 96 kW electric heaters F.L.A. HSE8 - Electrode boiler steam humidifier from 8 kg/h F.L.A. HSE9 - Electrode boiler steam humidifier from 15 kg/h F.L.A. FES - High efficiency H10 electrostatic air filter F.L.I. FULL LOAD POWER F.L.I. EH20 - 24 kW electric heaters F.L.I. EH24 - 36 kW electric heaters F.L.I. EH28 - 48 kW electric heaters F.L.I. EH72 - 72 kW electric heaters F.L.I. EH33 - 96 kW electric heaters F.L.I. HSE8 – Electrode boiler steam humidifier from 8 kg/h F.L.I. HSE9 - Electrode boiler steam humidifier from 15 kg/h F.L.I. FES – High efficiency H10 electrostatic air filter 362 402 452 464 524 604 704 804 904 A A A A A A A A 34.6 52.0 69.4 8.7 16.2 2.2 34.6 52.0 69.4 8.7 16.2 2.2 34.6 52.0 69.4 8.7 16.2 2.2 52.0 69.4 104.0 138.6 16.2 2.2 52.0 69.4 104.0 138.6 16.2 2.2 52.0 69.4 104.0 138.6 16.2 2.2 52.0 69.4 104.0 138.6 16.2 2.2 69.4 104.0 138.6 16.2 2.2 69.4 104.0 138.6 16.2 2.2 kW kW kW kW kW kW kW kW 24 36 48 6 11.25 0.5 24 36 48 6 11.25 0.5 24 36 48 6 11.25 0.5 36 48 72 96 11.25 1 36 48 72 96 11.25 1 36 48 72 96 11.25 1 36 48 72 96 11.25 1 48 72 96 11.25 1.25 48 72 96 11.25 1.25 CALCULATION OF BREAKAWAY CURRENT (M.I.C.) The calculation of the breakaway current (M.I.C.) is necessary in order to size the protection up the electrical line from the unit. Its value depends on the selected configuration and the components selected (motor sizes). The M.I.C. is obtained by summing the maximum breakaway current (L.R.A.) of the largest compressor and the input current at the maximum admissible conditions (F.L.A.) of the remaining electrical components. M.I.C. L.R.A.(C1) F.L.A.(C2) F.L.A.(C3) F.L.A.(C4) F.L.A.(Fan Ext.) N (Fan Ext.) F.L.A.(Fan Intake) F.L.A.(Fan Return) L.R.A. (C1) = breakaway current of the larger size compressor (Tandem 1). F.L.A. (C2) = input current of the smaller size compressor (Tandem 1). F.L.A. (C3) = input current of the larger size compressor (Tandem 2). F.L.A. (C4) = input current of the smaller size compressor (Tandem 2). F.L.A.(Fan Ext.) = current absorbed by the fan of the external section. No. (Fan Ext.) = number of fans of external section. F.L.A.(Fan Intake) = input current of supply fan. F.L.A.(Fan Return) = input current of return fan (only for version C). Example of calculation of the M.I.C. for units size 464 configuration C with standard supply fan (9 kW) and standard return fan (4 kW): BT08A006GB-03 M.I.C. = 173.0 + 15.2 + 30.6 + 15.2 + [4.1 x 4] + 19 + 8.3 = 277.7 A 12 PACKAGED 362 - 904 SOUND LEVELS Air flow: standard Sound Power Level (dB) Size Octave band (Hz) Sound pressure level Sound power level 63 125 250 500 1000 2000 4000 8000 dB(A) dB(A) 362 91 84 90 87 87 83 78 69 71 91 402 92 85 91 88 87 84 78 66 72 92 452 93 86 92 89 88 85 79 68 72 93 464 101 97 100 90 86 77 72 69 73 94 524 106 97 97 93 89 83 78 75 74 94 604 106 97 97 93 89 83 78 75 74 94 704 108 98 97 94 89 83 78 76 75 95 804 107 100 100 93 92 85 79 78 77 97 904 108 102 101 95 93 86 80 79 77 98 The sound levels are referred to units working at full load in nominal conditions. The sound pressure level is referred at a distance of 1 m. from the ducted unit surface working in free field conditions.External static pressure 50 Pa. (standard UNI EN ISO 3744) Please note that when the unit is installed in conditions other than nominal test conditions (e.g. near walls or obstacles in general), the sound levels may undergo substantial variations. OPERATING LIMITS (COOLING) THE LIMITS ARE INDICATIVE AND HAVE BEEN CALCULATED CONSIDERING: - VALUES GENERAL AND NOT SPECIFICATIONS, - STANDARD AIR FLOW-RATE, - NON-CRITICAL POSITIONING AND CORRECT USE OF THE UNIT, - OPERATION AT FULL LOAD WITH UNIT OPERATING IN INTAKE OF OUTSIDE AIR CALCULATE THE TEMPERATURES OF MIXES WHICH ARE GENERATED FROM THE EXCHANGERS' INLET TO KNOW THE LIMITS. TO = TEMPERATURE OF AIR ENTERING THE EXTERNAL EXCHANGER D.B.(°C) DB = DRY BULB TA = INTERNAL EXCHANGER INLET AIR TEMPERATURE W.B. (°C) WB = WET BULB (1) THE DASHED AREA REFERS TO THE FIELD OF UNITS OPERATION STANDARD (2) IN THE CROSS-HATCHED AREA IS IDENTIFIED THE UTILITY FIELD FOR UNIT WITH LOW TEMPERATURE DEVICE 30 Ta (W.B.) 25 (2) 20 (1) 15 10 5 0 5 10 15 20 25 30 35 40 45 50 To (D.B.) 30 25 To (D.B.) 20 (1) 15 (2) 10 5 0 -5 -15 -10 -5 0 Ta (W.B.) 5 10 15 20 THE LIMITS ARE INDICATIVE AND HAVE BEEN CALCULATED CONSIDERING: - VALUES GENERAL AND NOT SPECIFICATIONS, - STANDARD AIR FLOW-RATE, - NON-CRITICAL POSITIONING AND CORRECT USE OF THE UNIT, - OPERATION AT FULL LOAD WITH UNIT OPERATING IN INTAKE OF OUTSIDE AIR CALCULATE THE TEMPERATURES OF MIXES WHICH ARE GENERATED FROM THE EXCHANGERS' INLET TO KNOW THE LIMITS. TO = TEMPERATURE OF AIR ENTERING THE INTERNAL EXCHANGER D.B.(°C) DB = DRY BULB TA = EXTERNAL EXCHANGER INLET AIR TEMPERATURE W.B. (°C) WB = WET BULB (1) THE DASHED AREA REFERS TO THE FIELD OF UNITS OPERATION STANDARD (2) INSIDE THE DOTTED AREA, THE UNIT CAN OPERATE ONLY FOR A LIMITED PERIOD OF TIME (MAX 1 HOUR) IN EXTENDED OPERATING MODE, IN HEAT PUMP OPERATION WITH AN OUTSIDE AIR TEMPERATURE OF LESS THAN 6°C, THE UNIT PERFORMS DEFROSTS BY REVERSING THE CYCLE, SO AS TO ELIMINATE THE ICE THAT FORMS ON THE SURFACES OF THE OUTSIDE EXCHANGER; IN ADDITION, IN THE EVENT OF NEGATIVE TEMPERATURES, THE WATER RESULTING FROM THE DEFROSTS MUST BE DRAINED SO AS TO AVOID THE ACCUMULATION OF ICE NEAR THE BASE OF THE UNIT. MAKE SURE THAT THIS DOES NOT CONSTITUTE A DANGER FOR PEOPLE OR THINGS. BT08A006GB-03 OPERATING LIMITS (HEATING) 13 PACKAGED 362 - 904 AIR FLOW: STANDARD Size 362 402 452 464 524 604 704 804 904 5555 570 6111 570 6666 570 8056 570 9028 570 10000 510 11111 570 12500 570 13889 570 AIR HANDLING SECTION FANS (OUTLET) Air flow Max outside static pressure l/s Pa COOLING PERFORMANCE Size Ta (°C) DB/WB BT08A006GB-03 40 44 kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs 22 / 16 110,6 21,6 82,8 110,8 23,8 80,4 111,0 24,7 79,4 111,5 26,2 78,0 112,5 28,8 75,5 113,7 31,0 73,6 24 / 17 113,0 21,9 87,8 112,9 24,1 85,4 113,0 25,0 84,4 113,5 26,5 83,0 114,7 29,1 80,6 116,2 31,4 78,7 26 / 19 117,5 22,5 86,8 117,2 24,6 84,5 117,2 25,6 83,5 117,6 27,1 82,1 118,7 29,7 79,8 120,1 32,1 77,9 27 / 19,5 118,6 22,6 89,3 118,3 24,8 87,0 118,3 25,7 86,0 118,6 27,2 84,7 119,6 29,9 82,4 120,9 32,2 80,5 28 / 21 121,6 22,8 86,2 121,6 25,0 84,0 121,6 26,0 83,1 121,8 27,5 81,8 122,1 30,2 79,6 122,6 32,5 77,9 30 / 22 123,4 23,0 92,0 123,8 25,2 89,9 123,9 26,1 89,0 123,9 27,6 87,8 123,7 30,3 85,6 123,3 32,7 83,9 22 / 16 121,1 25,4 90,7 121,7 27,9 88,0 121,9 29,0 86,9 122,3 30,6 85,2 122,9 33,4 82,5 123,4 35,7 80,4 24 / 17 123,7 25,7 96,3 123,9 28,2 93,6 124,0 29,3 92,5 124,3 30,9 90,9 124,9 33,7 88,2 125,5 36,0 86,1 26 / 19 128,7 26,3 95,5 128,5 28,8 92,9 128,5 29,9 91,8 128,6 31,4 90,3 129,0 34,2 87,6 129,6 36,4 85,5 27 / 19,5 129,9 26,4 98,3 129,7 29,0 95,7 129,7 30,0 94,6 129,7 31,6 93,0 130,1 34,3 90,4 130,6 36,5 88,3 28 / 21 133,5 26,8 94,4 133,3 29,3 91,8 133,3 30,4 90,8 133,3 31,9 89,2 133,3 34,6 86,6 133,3 36,8 84,5 30 / 22 135,8 27,0 99,5 135,9 29,6 96,9 135,8 30,6 95,8 135,7 32,2 94,2 135,4 34,9 91,6 135,0 37,0 89,5 22 / 16 131,1 29,3 97,9 131,3 32,1 95,0 131,5 33,4 93,8 131,8 35,2 92,1 132,4 38,4 89,2 133,1 41,2 86,9 24 / 17 133,5 29,7 103,1 133,4 32,5 100,2 133,5 33,7 99,1 133,7 35,5 97,4 134,5 38,8 94,5 135,5 41,6 92,2 26 / 19 138,9 30,3 100,7 138,3 33,1 97,8 138,3 34,3 96,7 138,3 36,2 95,0 138,9 39,6 92,1 139,8 42,5 89,8 27 / 19,5 140,4 30,4 103,4 139,7 33,3 100,5 139,6 34,5 99,4 139,6 36,4 97,7 140,1 39,8 94,9 140,8 42,7 92,6 28 / 21 145,3 30,8 101,6 144,4 33,8 98,8 144,2 35,0 97,7 143,8 37,0 96,0 143,6 40,4 93,1 143,6 43,4 90,9 30 / 22 148,8 30,9 111,7 147,9 34,1 108,9 147,5 35,4 107,8 147,0 37,4 106,1 146,0 40,9 103,2 145,2 43,8 101,0 22 / 16 147,7 28,0 112,0 147,0 30,8 108,9 147,2 32,1 107,6 147,8 34,0 105,7 149,9 37,4 102,6 152,7 40,3 100,1 24 / 17 150,3 28,2 119,0 150,8 31,1 116,0 151,1 32,3 114,8 151,5 34,2 113,0 152,2 37,6 110,1 153,0 40,4 107,7 26 / 19 156,2 28,7 117,6 157,3 31,6 114,8 157,4 32,8 113,6 157,5 34,7 111,9 157,0 38,0 109,1 156,0 40,8 106,9 27 / 19,5 157,8 28,8 121,3 158,6 31,7 118,4 158,8 33,0 117,3 158,7 34,8 115,6 158,2 38,1 112,8 157,2 40,9 110,5 28 / 21 162,9 29,1 117,3 162,1 32,1 114,3 162,0 33,3 113,1 161,8 35,2 111,4 161,9 38,5 108,4 162,3 41,2 106,1 30 / 22 166,5 29,4 125,8 164,0 32,4 122,7 163,5 33,6 121,5 163,3 35,4 119,6 164,4 38,7 116,5 22 / 16 165,6 34,1 125,0 166,2 37,4 121,5 166,4 38,9 120,0 166,5 41,2 117,9 166,5 45,3 114,3 166,3 49,0 111,4 24 / 17 168,8 34,3 132,3 169,4 37,8 128,9 169,5 39,3 127,5 169,5 41,6 125,4 169,0 45,8 121,9 168,2 49,3 119,1 26 / 19 175,2 34,9 130,5 175,9 38,4 127,1 175,9 39,9 125,8 175,8 42,3 123,8 174,8 46,4 120,4 173,5 49,9 117,7 27 / 19,5 176,8 35,1 134,3 177,5 38,5 131,0 177,6 40,0 129,6 177,4 42,3 127,6 176,5 46,5 124,2 175,1 50,0 121,5 28 / 21 181,7 35,7 130,6 182,5 38,7 127,1 182,6 40,1 125,7 182,6 42,4 123,7 182,0 46,6 120,3 180,9 50,4 117,5 30 / 22 184,9 36,1 140,4 185,8 38,7 136,9 186,0 40,0 135,5 186,2 42,2 133,4 186,0 46,5 129,9 185,5 50,6 127,0 22 / 16 192,4 37,8 144,8 192,5 41,6 140,7 192,8 43,3 139,1 193,5 45,9 136,6 195,1 50,5 132,5 197,0 54,4 129,3 24 / 17 195,8 38,2 154,4 195,8 42,2 150,4 196,0 43,8 148,8 196,6 46,4 146,4 198,5 50,9 142,5 200,6 54,6 139,3 26 / 19 203,0 39,1 153,7 202,7 43,1 149,9 202,9 44,8 148,4 203,4 47,3 146,1 205,3 51,6 142,3 207,6 55,2 139,3 27 / 19,5 204,9 39,2 158,3 204,5 43,3 154,6 204,7 44,9 153,1 205,2 47,5 150,8 207,0 51,8 147,1 209,3 55,4 144,0 28 / 21 210,5 39,7 151,3 210,2 43,7 147,6 210,3 45,4 146,1 210,8 47,9 143,9 212,3 52,4 140,2 214,2 56,1 137,2 30 / 22 214,3 40,0 158,0 214,1 43,9 154,3 214,2 45,6 152,8 214,6 48,2 150,6 215,9 52,8 147,0 22 / 16 212,9 45,5 160,0 213,2 50,1 155,5 213,5 52,1 153,7 214,2 55,2 151,0 216,1 60,7 146,5 218,1 65,5 142,9 24 / 17 216,8 46,1 170,1 216,6 50,7 165,6 216,9 52,6 163,9 217,6 55,7 161,2 219,8 61,2 156,8 222,4 65,9 153,3 524 14 35 kWs 464 704 32 kWe 402 604 30 kWf 362 452 EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) 25 26 / 19 225,5 47,0 169,1 224,9 51,7 164,8 225,0 53,7 163,0 225,6 56,8 160,4 227,6 62,3 156,0 230,3 67,0 152,5 27 / 19,5 227,9 47,2 174,2 227,2 51,9 169,8 227,3 53,9 168,1 227,8 57,1 165,5 229,6 62,6 161,1 232,1 67,3 157,6 28 / 21 235,7 47,8 166,9 235,0 52,7 162,5 234,9 54,8 160,7 235,0 58,0 158,1 235,8 63,6 153,6 237,0 68,4 150,1 30 / 22 241,3 48,1 175,6 240,7 53,2 171,0 240,5 55,3 169,2 240,3 58,6 166,5 240,1 64,4 162,0 240,0 69,3 158,3 Ta = ambient air temperature D.B/W.B DB = dry bulb WB = wet bulb kWf = Cooling capacity in kW kWe = Compressor power input in kW kWs = sensible cooling capacity (kW) Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) the cooling capacities have not accounted for the heat dissipation of the centrifugal fan motors. PACKAGED 362 - 904 AIR FLOW: STANDARD COOLING PERFORMANCE Size 804 904 Ta (°C) DB/WB EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) 25 30 32 35 40 44 kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs 22 / 16 256,7 48,6 193,8 259,3 53,3 188,5 260,2 55,4 186,3 261,4 58,6 183,2 262,8 64,3 177,8 263,6 69,2 173,6 24 / 17 262,5 49,0 207,8 263,2 53,9 202,6 263,7 55,9 200,5 264,7 59,1 197,4 267,1 64,7 192,2 269,7 69,3 188,0 26 / 19 274,0 49,8 208,6 272,2 54,9 203,4 272,1 57,0 201,3 272,9 60,1 198,2 276,0 65,4 193,0 280,3 69,7 188,9 27 / 19,5 276,7 50,0 214,8 274,7 55,1 209,6 274,6 57,2 207,5 275,2 60,4 204,4 278,3 65,6 199,1 282,6 69,8 194,9 28 / 21 285,0 50,6 203,4 282,9 55,8 197,9 282,7 57,9 195,7 283,0 61,0 192,4 285,3 66,2 187,0 288,6 70,3 182,6 30 / 22 290,3 51,0 206,7 288,9 56,2 201,0 288,8 58,3 198,7 288,9 61,4 195,3 290,0 66,6 189,6 22 / 16 281,7 55,9 212,7 282,0 61,2 206,7 282,3 63,4 204,3 282,9 67,0 200,7 284,5 73,5 194,6 286,2 79,0 189,8 24 / 17 287,6 56,3 226,5 287,5 61,8 220,6 287,6 64,1 218,2 287,9 67,8 214,7 288,9 74,2 208,7 290,1 79,7 204,0 26 / 19 299,1 57,3 224,7 298,3 63,1 218,9 298,2 65,5 216,6 298,0 69,2 213,1 298,2 75,6 207,4 298,7 81,0 202,7 27 / 19,5 302,0 57,6 231,7 301,0 63,4 225,9 300,8 65,8 223,6 300,6 69,5 220,2 300,7 76,0 214,4 301,1 81,4 209,8 28 / 21 310,3 58,5 223,0 309,1 64,3 217,3 308,7 66,7 215,0 308,4 70,5 211,5 308,3 77,0 205,8 308,6 82,4 201,2 30 / 22 315,8 59,2 237,2 314,4 64,9 231,5 314,0 67,3 229,2 313,7 71,0 225,7 313,6 77,6 219,9 314,1 83,1 215,3 BT08A006GB-03 Ta = ambient air temperature D.B/W.B DB = dry bulb WB = wet bulb kWf = Cooling capacity in kW kWe = Compressor power input in kW kWs = sensible cooling capacity (kW) Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) the cooling capacities have not accounted for the heat dissipation of the centrifugal fan motors. 15 PACKAGED 362 - 904 AIR FLOW: STANDARD Size 362 402 452 464 524 604 704 804 904 5555 570 6111 570 6666 570 8056 570 9028 570 10000 510 11111 570 12500 570 13889 570 AIR HANDLING SECTION FANS (OUTLET) Air flow Max outside static pressure l/s Pa HEATING PERFORMANCE Size Ta (°C) DB/WB RETURN AIR TEMPERATURE (D.B.) 10 kWt 15 kWe -5 / -5,4 18 19 20 21 25 kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe 92,3 17,0 92,8 17,7 93,0 17,9 93,2 18,2 93,4 18,4 94,5 19,5 0 / -0,6 100,6 16,9 101,1 18,1 101,6 18,9 101,8 19,2 102,0 19,5 102,2 19,7 103,2 21,0 5 / 3,9 110,2 18,1 110,5 19,4 110,9 20,3 111,1 20,7 111,2 21,0 111,4 21,3 112,3 22,7 362 7 / 6,1 115,3 18,8 115,6 20,2 115,9 21,2 116,0 21,5 116,1 21,8 116,3 22,2 117,0 23,7 10 / 8,2 120,5 19,6 120,7 21,1 120,9 22,0 120,9 22,4 121,0 22,7 121,2 23,1 121,7 24,6 15 / 13 133,4 21,5 133,2 23,2 133,1 24,3 133,1 24,7 133,1 25,1 133,1 25,5 133,1 27,1 -5 / -5,4 100,2 18,1 103,3 19,5 104,8 20,4 105,3 20,7 105,7 21,0 106,1 21,3 107,5 22,6 0 / -0,6 111,8 19,4 113,2 20,9 114,1 21,8 114,4 22,2 114,7 22,5 115,0 22,9 116,3 24,4 5 / 3,9 123,0 20,9 123,8 22,6 124,4 23,6 124,6 24,0 124,8 24,4 125,0 24,8 126,1 26,4 7 / 6,1 128,6 21,8 129,4 23,5 129,9 24,7 130,1 25,0 130,3 25,4 130,5 25,9 131,3 27,6 10 / 8,2 134,0 22,6 135,1 24,5 135,6 25,7 135,8 26,1 135,9 26,5 136,1 27,0 136,6 28,7 15 / 13 146,5 24,8 149,0 27,0 149,8 28,4 149,9 28,9 150,1 29,4 150,1 29,8 149,8 31,7 -5 / -5,4 112,0 20,8 110,6 21,9 111,0 22,7 111,3 23,0 111,7 23,4 112,2 23,7 115,3 25,3 0 / -0,6 122,8 22,1 123,0 23,6 123,5 24,6 123,8 25,0 124,1 25,3 124,4 25,7 126,1 27,4 5 / 3,9 134,2 23,7 135,0 25,5 135,6 26,7 135,8 27,1 136,0 27,5 136,2 27,9 137,2 29,7 7 / 6,1 140,2 24,6 141,0 26,6 141,6 27,8 141,8 28,2 142,0 28,7 142,2 29,1 143,0 31,0 10 / 8,2 146,1 25,6 146,8 27,6 147,3 29,0 147,5 29,4 147,7 29,9 147,9 30,4 148,8 32,4 15 / 13 160,8 28,1 160,5 30,4 160,8 31,9 160,9 32,4 161,1 32,9 161,4 33,4 162,8 35,7 121,8 21,4 123,9 22,6 124,6 23,0 125,3 23,4 125,9 23,8 128,4 25,4 402 452 -5 / -5,4 0 / -0,6 133,3 21,3 134,6 23,1 135,6 24,3 135,9 24,7 136,3 25,1 136,7 25,5 138,5 27,3 5 / 3,9 146,8 23,1 147,3 25,0 147,9 26,3 148,1 26,7 148,3 27,2 148,6 27,6 149,7 29,5 464 7 / 6,1 153,0 24,0 153,8 26,0 154,4 27,4 154,6 27,8 154,8 28,3 155,0 28,8 155,9 30,8 10 / 8,2 158,7 24,9 160,1 27,1 160,8 28,5 161,1 29,0 161,3 29,5 161,5 30,0 162,3 32,1 15 / 13 171,1 27,1 175,1 29,7 176,7 31,4 177,1 31,9 177,5 32,5 177,8 33,0 178,2 35,3 136,2 25,8 134,2 26,8 133,8 27,1 133,6 27,5 133,4 27,9 134,5 29,5 -5 / -5,4 0 / -0,6 152,0 25,8 149,9 27,6 149,4 28,9 149,4 29,3 149,5 29,7 149,6 30,2 150,8 32,2 5 / 3,9 164,8 27,7 164,9 29,9 165,1 31,3 165,2 31,8 165,4 32,3 165,6 32,9 166,4 35,0 7 / 6,1 172,4 28,8 173,0 31,2 173,3 32,7 173,4 33,2 173,5 33,8 173,7 34,3 174,1 36,6 10 / 8,2 180,6 30,0 181,2 32,5 181,4 34,1 181,5 34,7 181,5 35,2 181,6 35,8 181,6 38,1 15 / 13 202,2 33,2 201,7 36,0 201,1 37,7 200,9 38,3 200,6 38,9 200,3 39,5 199,0 42,0 157,4 28,7 158,4 30,0 158,8 30,4 159,3 30,9 159,8 31,4 162,4 33,4 0 / -0,6 172,7 28,4 174,0 30,7 174,8 32,1 175,1 32,6 175,4 33,1 175,7 33,7 177,0 35,8 5 / 3,9 189,7 30,6 191,0 33,1 191,6 34,7 191,7 35,2 191,9 35,8 192,0 36,3 192,5 38,7 7 / 6,1 198,7 31,8 199,7 34,4 200,2 36,1 200,3 36,6 200,4 37,2 200,5 37,8 200,6 40,3 10 / 8,2 207,6 33,1 208,4 35,8 208,7 37,5 208,8 38,1 208,8 38,7 208,9 39,3 208,8 41,9 15 / 13 229,7 36,4 229,4 39,3 229,3 41,2 229,2 41,9 229,2 42,6 229,1 43,3 228,9 46,1 -5 / -5,4 179,0 31,9 179,1 33,9 179,5 35,2 179,6 35,7 179,8 36,2 179,9 36,7 180,8 38,8 0 / -0,6 195,2 33,9 195,9 36,2 196,4 37,8 196,6 38,3 196,9 38,9 197,1 39,5 198,2 41,9 5 / 3,9 213,0 36,3 213,8 39,0 214,5 40,8 214,7 41,5 215,0 42,1 215,2 42,8 216,5 45,5 7 / 6,1 222,6 37,7 223,4 40,6 224,0 42,5 224,3 43,2 224,5 43,9 224,8 44,6 226,0 47,5 10 / 8,2 232,3 39,2 233,0 42,3 233,6 44,3 233,8 45,0 234,1 45,7 234,4 46,5 235,6 49,6 15 / 13 256,5 43,0 256,8 46,5 257,2 48,8 257,4 49,6 257,6 50,4 257,8 51,3 258,9 54,7 524 BT08A006GB-03 -5 / -5,4 604 704 Ta = Outside air temperature (°C) DB = dry bulb WB = wet bulb kWt = Heating capacity (kW) with coils free of ice kWe = Compressor power input in kW Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) not all thermal yields take into account the heat dissipated by the fan motors 16 PACKAGED 362 - 904 AIR FLOW: STANDARD HEATING PERFORMANCE Size Ta (°C) DB/WB RETURN AIR TEMPERATURE (D.B.) 10 kWt 15 kWe -5 / -5,4 804 19 20 21 25 kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe 211,1 38,5 210,1 39,8 210,0 40,2 210,1 40,7 210,2 41,3 212,1 43,7 0 / -0,6 236,6 38,0 236,9 40,6 237,4 42,3 237,6 42,9 237,8 43,5 238,0 44,2 239,1 46,9 5 / 3,9 261,2 40,5 262,4 43,7 263,0 45,7 263,1 46,4 263,2 47,1 263,4 47,8 263,7 50,8 7 / 6,1 274,8 42,4 275,3 45,7 275,5 47,8 275,5 48,5 275,5 49,2 275,6 50,0 275,5 53,0 10 / 8,2 288,7 44,5 287,9 47,8 287,4 49,9 287,3 50,7 287,2 51,4 287,1 52,2 286,7 55,4 15 / 13 324,1 50,6 317,6 53,5 314,8 55,7 314,0 56,4 313,4 57,2 312,9 58,0 311,7 61,6 237,0 42,9 236,6 44,4 236,8 45,0 237,0 45,5 237,4 46,1 239,9 48,7 0 / -0,6 261,8 43,1 261,5 45,9 261,9 47,8 262,1 48,4 262,4 49,1 262,7 49,8 264,4 52,7 5 / 3,9 287,8 46,3 288,0 49,5 288,3 51,7 288,5 52,4 288,6 53,2 288,8 54,0 289,6 57,3 7 / 6,1 302,5 48,2 302,3 51,6 302,3 53,9 302,3 54,7 302,3 55,5 302,4 56,3 302,7 59,7 10 / 8,2 317,7 50,2 316,6 53,8 316,2 56,2 316,0 57,0 315,9 57,8 315,8 58,7 315,6 62,2 15 / 13 356,7 55,7 352,2 59,5 350,2 62,0 349,6 62,9 349,0 63,8 348,5 64,7 347,0 68,6 -5 / -5,4 904 18 Ta = Outside air temperature (°C) DB = dry bulb WB = wet bulb kWt = Heating capacity (kW) with coils free of ice kWe = Compressor power input in kW Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) not all thermal yields take into account the heat dissipated by the fan motors INTEGRATED HEATING CAPACITIES Air temperature external exchanger inlet °C (D.B. / W.B.) Heating capacity multiplication coefficient -5 / -5.4 0,89 0 / -0.6 0,88 5 / 3.9 0,94 OTHERS 1 BT08A006GB-03 To obtain the integrated heating capacities (the real heating capacity considering the defrost cycles too), multiply the kWt value in the heating performance tables by the following coefficient. DB = dry bulb WB = wet bulb In case of below zero air ambient temperature with a long period of heat pump operating mode it is necessary to help the evacuation of the water produced during the defrost cycle; this to avoid the formation of ice in the unit basement. Pay attention that the evacuation will not create inconveniences to things or persons. 17 PACKAGED 362 - 904 Size AIR FLOW: REDUCED 362 402 452 464 524 604 704 804 904 4444 570 6389 510 7222 570 8056 570 8888 510 10000 570 11111 510 AIR HANDLING SECTION FANS (OUTLET) Air flow Max outside static pressure l/s Pa 4888 570 5333 570 COOLING PERFORMANCE Size Ta (°C) DB/WB BT08A006GB-03 35 40 44 kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs 24 / 17 106,3 21,9 79,2 106,9 24,2 77,1 107,3 25,2 76,3 108,0 26,7 75,1 109,8 29,3 73,1 111,6 31,6 71,5 26 / 19 112,0 22,1 79,0 112,0 24,4 76,9 112,1 25,4 76,0 112,5 26,9 74,8 113,5 29,6 72,7 114,7 31,9 71,1 27 / 19,5 113,3 22,2 81,1 113,2 24,5 79,0 113,3 25,4 78,1 113,6 27,0 76,9 114,5 29,7 74,8 115,6 32,0 73,1 28 / 21 116,9 22,5 78,3 116,6 24,8 76,2 116,6 25,7 75,4 116,8 27,3 74,1 117,5 30,0 72,0 118,5 32,4 70,4 30 / 22 119,0 22,7 82,2 118,7 25,0 80,2 118,7 26,0 79,3 118,9 27,5 78,1 119,7 30,3 76,0 120,7 32,7 74,4 32 / 23,5 121,7 23,1 83,7 121,6 25,4 81,6 121,7 26,4 80,8 122,0 28,0 79,6 123,1 30,7 77,6 124,3 33,1 76,0 24 / 17 118,2 25,4 87,2 119,0 28,0 84,7 119,3 29,1 83,7 119,6 30,7 82,2 119,9 33,4 79,8 120,0 35,7 77,8 26 / 19 123,0 26,0 86,2 123,3 28,5 83,7 123,4 29,6 82,7 123,6 31,2 81,3 123,7 34,0 78,8 123,8 36,3 76,8 27 / 19,5 124,2 26,1 88,4 124,4 28,6 85,9 124,5 29,7 84,9 124,6 31,3 83,4 124,8 34,1 81,0 124,9 36,4 79,0 28 / 21 127,9 26,5 85,9 128,0 29,0 83,4 128,0 30,1 82,4 128,0 31,7 80,8 128,2 34,5 78,3 128,3 36,8 76,2 30 / 22 130,5 26,8 91,4 130,4 29,3 88,7 130,4 30,4 87,7 130,4 32,0 86,1 130,6 34,7 83,4 130,7 37,0 81,3 32 / 23,5 134,4 27,2 95,9 134,2 29,8 93,1 134,2 30,8 92,0 134,3 32,4 90,3 134,4 35,1 87,5 134,7 37,2 85,2 24 / 17 127,7 29,2 93,4 127,7 32,2 90,9 127,8 33,5 89,9 128,1 35,4 88,4 128,9 38,9 85,8 129,7 41,8 83,8 26 / 19 132,5 29,6 92,4 133,1 32,7 89,7 133,4 34,0 88,7 133,6 35,9 87,1 134,0 39,3 84,4 134,1 42,2 82,3 27 / 19,5 133,8 29,7 94,8 134,5 32,8 92,1 134,7 34,1 91,0 134,9 36,1 89,4 135,2 39,5 86,8 135,2 42,3 84,7 28 / 21 138,1 30,2 92,1 138,4 33,3 89,4 138,5 34,6 88,3 138,6 36,6 86,7 138,5 40,0 84,0 138,2 42,9 81,8 30 / 22 141,1 30,5 97,2 141,0 33,7 94,5 140,9 35,0 93,4 140,8 37,0 91,8 140,5 40,4 89,1 140,2 43,3 86,9 32 / 23,5 145,9 31,1 99,7 144,8 34,3 97,0 144,4 35,6 95,9 143,9 37,6 94,2 143,2 41,2 91,5 142,9 44,1 89,4 24 / 17 147,2 27,6 107,6 144,3 30,5 104,8 144,0 31,7 103,7 144,6 33,6 102,1 148,2 37,0 99,4 153,5 39,8 97,2 26 / 19 150,5 28,3 106,8 149,7 31,3 103,9 149,6 32,5 102,7 149,8 34,4 101,0 151,0 37,8 98,1 152,6 40,7 95,8 27 / 19,5 151,6 28,5 109,7 151,1 31,5 106,8 151,1 32,7 105,6 151,3 34,6 103,8 152,0 38,0 100,9 153,1 40,9 98,6 28 / 21 155,5 28,9 106,0 155,6 31,9 103,0 155,7 33,2 101,8 155,7 35,1 100,1 155,9 38,4 97,1 156,1 41,2 94,7 30 / 22 158,6 29,2 111,7 158,8 32,2 108,8 158,8 33,4 107,6 158,9 35,3 105,8 159,2 38,6 102,8 159,4 41,4 100,5 32 / 23,5 164,0 29,5 114,0 163,7 32,5 111,1 163,8 33,7 109,9 164,1 35,6 108,2 165,1 38,8 105,3 24 / 17 162,0 33,9 121,0 162,1 37,7 117,7 162,1 39,3 116,3 162,1 41,8 114,3 162,1 46,1 110,9 162,1 49,6 108,1 26 / 19 167,7 34,5 120,3 167,6 38,3 116,9 167,6 39,9 115,6 167,6 42,3 113,6 167,8 46,4 110,3 168,1 49,8 107,6 27 / 19,5 169,4 34,7 123,5 169,1 38,4 120,2 169,1 40,0 118,9 169,1 42,4 116,9 169,2 46,5 113,6 169,5 49,9 110,9 28 / 21 175,3 35,1 119,0 174,3 38,8 115,6 173,9 40,3 114,3 173,6 42,7 112,3 173,3 46,9 109,0 173,3 50,4 106,3 524 18 32 kWs 464 704 30 kWe 402 604 25 kWf 362 452 EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) 30 / 22 179,8 35,3 124,8 178,0 39,0 121,4 177,5 40,5 120,1 176,8 42,9 118,1 176,0 47,2 114,7 175,7 50,9 112,0 32 / 23,5 187,4 35,6 125,8 184,3 39,2 122,3 183,2 40,7 120,9 181,8 43,2 118,8 179,9 47,8 115,3 178,8 51,8 112,6 24 / 17 188,0 37,8 138,6 188,5 41,7 135,2 188,8 43,4 133,8 189,5 46,1 131,8 191,0 51,0 128,4 192,5 55,2 125,7 26 / 19 194,6 38,6 139,1 195,3 42,6 135,6 195,7 44,3 134,1 196,4 47,0 132,0 197,7 51,8 128,5 199,0 55,9 125,7 27 / 19,5 196,4 38,8 142,9 197,0 42,8 139,3 197,4 44,5 137,9 198,1 47,2 135,8 199,4 51,9 132,2 200,8 56,0 129,4 28 / 21 202,1 39,3 138,3 202,4 43,3 134,7 202,6 45,0 133,3 203,2 47,7 131,1 204,7 52,4 127,6 206,4 56,4 124,7 30 / 22 206,3 39,6 145,1 206,0 43,7 141,5 206,1 45,4 140,1 206,6 48,0 138,0 208,3 52,7 134,4 210,3 56,6 131,6 32 / 23,5 213,0 40,0 147,4 211,5 44,1 143,9 211,3 45,8 142,5 211,7 48,4 140,4 213,7 53,0 137,0 216,6 56,8 134,2 24 / 17 209,0 45,5 155,6 208,3 50,3 150,7 208,4 52,3 148,7 208,8 55,5 145,8 210,4 61,4 140,8 212,5 66,4 136,8 26 / 19 216,2 46,4 153,7 215,8 51,1 149,3 215,8 53,2 147,5 216,2 56,5 144,8 217,3 62,3 140,3 218,8 67,5 136,8 27 / 19,5 218,3 46,6 157,7 217,8 51,4 153,4 217,9 53,4 151,6 218,1 56,7 149,0 219,2 62,6 144,7 220,6 67,8 141,2 28 / 21 225,7 47,2 151,5 224,5 52,1 147,4 224,3 54,2 145,8 224,3 57,5 143,4 225,2 63,5 139,3 226,5 68,8 136,0 30 / 22 231,3 47,5 159,2 229,4 52,5 155,2 228,9 54,7 153,7 228,7 58,1 151,3 229,4 64,2 147,4 231,0 69,5 144,2 32 / 23,5 240,9 48,0 161,8 237,3 53,2 158,0 236,4 55,5 156,5 235,7 59,0 154,3 236,3 65,3 150,5 238,2 70,7 147,5 Ta = ambient air temperature D.B/W.B DB = dry bulb WB = wet bulb kWf = Cooling capacity in kW kWe = Compressor power input in kW kWs = sensible cooling capacity (kW) Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) the cooling capacities have not accounted for the heat dissipation of the centrifugal fan motors. PACKAGED 362 - 904 AIR FLOW: REDUCED COOLING PERFORMANCE Size 804 904 Ta (°C) DB/WB EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) 25 30 32 35 40 44 kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs 24 / 17 251,6 48,3 186,9 251,9 53,5 181,3 252,1 55,7 179,1 252,6 59,0 175,8 253,9 64,8 170,3 255,3 69,7 165,9 26 / 19 261,6 49,2 186,7 262,2 54,3 181,4 262,5 56,5 179,3 262,9 59,7 176,1 263,5 65,4 170,8 264,1 70,2 166,5 27 / 19,5 264,2 49,4 191,5 264,8 54,5 186,2 265,1 56,7 184,1 265,4 59,9 181,0 266,0 65,6 175,7 266,4 70,4 171,5 28 / 21 272,5 50,1 184,8 272,8 55,2 179,7 272,9 57,2 177,7 273,0 60,5 174,6 273,2 66,1 169,5 273,2 70,8 165,4 30 / 22 278,3 50,6 193,4 278,2 55,6 188,4 278,1 57,6 186,4 278,1 60,8 183,4 278,0 66,4 178,4 277,9 71,1 174,4 32 / 23,5 287,4 51,3 196,2 286,4 56,2 191,4 286,0 58,2 189,5 285,6 61,4 186,6 285,2 66,9 181,7 285,0 71,5 177,9 24 / 17 275,2 55,6 202,4 275,0 61,4 197,0 275,1 63,8 194,8 275,5 67,6 191,6 276,7 74,2 186,2 278,2 79,9 181,9 26 / 19 286,8 56,6 202,2 285,8 62,5 196,9 285,6 64,9 194,7 285,6 68,8 191,5 286,4 75,5 186,1 287,6 81,1 181,8 27 / 19,5 289,6 56,8 207,7 288,5 62,8 202,3 288,3 65,2 200,2 288,3 69,1 197,0 288,9 75,7 191,6 290,0 81,4 187,3 28 / 21 297,6 57,7 201,0 296,8 63,6 195,6 296,7 66,0 193,5 296,6 69,9 190,3 296,8 76,5 184,9 297,3 82,2 180,6 30 / 22 302,6 58,3 211,5 302,4 64,1 206,1 302,4 66,6 204,0 302,3 70,4 200,8 302,3 77,0 195,5 302,4 82,7 191,2 32 / 23,5 309,7 59,2 215,5 310,9 64,9 210,2 311,1 67,3 208,1 311,3 71,0 204,9 311,0 77,7 199,6 310,1 83,3 195,4 BT08A006GB-03 Ta = ambient air temperature D.B/W.B DB = dry bulb WB = wet bulb kWf = Cooling capacity in kW kWe = Compressor power input in kW kWs = sensible cooling capacity (kW) Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) the cooling capacities have not accounted for the heat dissipation of the centrifugal fan motors. 19 PACKAGED 362 - 904 AIR FLOW: REDUCED Size 362 402 452 464 524 604 704 804 904 4444 570 4888 570 5333 570 6389 510 7222 570 8056 570 8888 510 10000 570 11111 510 AIR HANDLING SECTION FANS (OUTLET) Air flow Max outside static pressure l/s Pa HEATING PERFORMANCE Size Ta (°C) DB/WB RETURN AIR TEMPERATURE (D.B.) 10 15 18 19 20 21 25 kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe -5 / -5,4 90,1 16,7 89,6 17,8 89,6 18,5 89,7 18,8 89,9 19,1 90,0 19,4 91,0 20,6 0 / -0,6 99,2 18,0 99,2 19,3 99,2 20,2 99,2 20,5 99,3 20,8 99,3 21,1 99,5 22,4 5 / 3,9 108,8 19,6 108,8 21,1 108,9 22,1 108,9 22,4 108,9 22,8 108,9 23,1 109,1 24,6 7 / 6,1 113,9 20,5 113,7 22,1 113,8 23,1 113,8 23,5 113,9 23,9 114,0 24,2 114,4 25,9 10 / 8,2 119,0 21,4 118,6 23,1 118,6 24,2 118,7 24,6 118,8 25,0 119,0 25,4 119,8 27,2 362 15 / 13 131,4 23,8 130,1 25,6 130,2 26,9 130,5 27,4 130,8 27,9 131,2 28,4 133,6 30,6 -5 / -5,4 98,8 19,1 101,4 20,7 102,6 21,7 103,0 22,0 103,3 22,4 103,6 22,7 104,5 24,2 0 / -0,6 110,9 20,8 112,2 22,5 112,9 23,6 113,2 24,0 113,5 24,4 113,7 24,8 114,7 26,5 5 / 3,9 121,9 22,7 122,6 24,6 123,1 25,8 123,2 26,2 123,4 26,6 123,6 27,1 124,4 28,9 402 7 / 6,1 127,3 23,7 127,8 25,7 128,2 27,0 128,3 27,4 128,4 27,8 128,6 28,3 129,1 30,2 10 / 8,2 132,4 24,7 132,9 26,8 133,1 28,2 133,2 28,6 133,3 29,1 133,4 29,5 133,7 31,5 15 / 13 143,8 27,3 144,7 29,7 144,9 31,2 144,8 31,7 144,8 32,2 144,7 32,7 144,1 34,6 -5 / -5,4 108,2 21,7 110,9 23,3 112,2 24,4 112,6 24,8 113,0 25,2 113,4 25,5 114,5 27,2 0 / -0,6 121,0 23,6 122,6 25,4 123,5 26,6 123,8 27,1 124,1 27,5 124,4 27,9 125,5 29,8 5 / 3,9 132,9 25,6 133,7 27,7 134,3 29,1 134,6 29,5 134,8 30,0 135,0 30,5 136,0 32,6 7 / 6,1 138,6 26,7 139,3 28,9 139,8 30,4 139,9 30,9 140,1 31,4 140,3 31,9 141,1 34,0 10 / 8,2 144,0 27,9 144,6 30,2 145,0 31,7 145,2 32,2 145,3 32,7 145,5 33,3 146,1 35,4 15 / 13 156,3 30,8 157,0 33,4 157,3 35,0 157,4 35,6 157,4 36,1 157,4 36,7 157,4 39,0 -5 / -5,4 117,6 21,1 118,3 22,8 119,7 24,0 120,3 24,4 121,0 24,9 121,7 25,3 125,6 27,4 0 / -0,6 130,7 22,9 131,7 24,9 132,5 26,2 132,8 26,6 133,1 27,1 133,5 27,5 134,9 29,5 5 / 3,9 143,5 24,9 144,4 27,1 144,9 28,6 145,1 29,0 145,3 29,5 145,5 30,1 146,4 32,2 7 / 6,1 150,0 26,1 150,6 28,4 151,1 29,9 151,3 30,4 151,6 30,9 151,8 31,4 152,9 33,7 10 / 8,2 156,4 27,2 156,5 29,6 157,1 31,2 157,4 31,7 157,7 32,3 158,0 32,9 159,8 35,4 15 / 13 171,4 30,1 170,2 32,7 171,1 34,5 171,6 35,1 172,3 35,8 173,1 36,5 177,8 39,6 -5 / -5,4 131,5 25,3 134,7 27,5 134,2 28,7 133,7 29,0 132,9 29,3 132,0 29,7 126,3 30,7 0 / -0,6 147,8 27,5 148,7 29,8 148,6 31,2 148,5 31,6 148,3 32,1 148,0 32,6 146,6 34,5 5 / 3,9 163,5 30,0 163,3 32,5 163,3 34,0 163,3 34,6 163,3 35,1 163,3 35,7 163,4 38,1 452 464 BT08A006GB-03 524 7 / 6,1 171,3 31,4 171,0 34,0 170,9 35,6 170,9 36,2 170,8 36,8 170,8 37,4 170,9 39,9 10 / 8,2 178,8 32,8 178,6 35,5 178,4 37,3 178,3 37,9 178,2 38,5 178,1 39,1 177,6 41,6 15 / 13 196,3 36,4 197,2 39,6 196,5 41,5 196,0 42,1 195,5 42,7 194,8 43,3 191,2 45,7 -5 / -5,4 154,1 28,0 154,6 30,3 155,2 31,7 155,4 32,2 155,7 32,7 155,9 33,2 157,2 35,3 0 / -0,6 170,5 30,4 171,1 32,8 171,6 34,4 171,7 34,9 171,9 35,5 172,1 36,1 173,0 38,4 5 / 3,9 187,6 33,1 188,0 35,8 188,2 37,5 188,3 38,1 188,3 38,8 188,4 39,4 188,8 42,0 604 704 7 / 6,1 196,6 34,6 196,7 37,4 196,7 39,3 196,8 39,9 196,8 40,6 196,8 41,2 196,8 44,0 10 / 8,2 205,5 36,1 205,3 39,2 205,2 41,1 205,1 41,8 205,1 42,4 205,0 43,1 204,8 46,0 15 / 13 227,1 40,1 226,1 43,5 225,4 45,7 225,2 46,4 224,9 47,2 224,7 47,9 223,6 51,1 -5 / -5,4 175,1 33,5 170,3 35,3 169,6 36,7 169,7 37,3 170,0 37,8 170,5 38,4 174,2 41,0 0 / -0,6 192,1 36,0 191,1 38,6 191,2 40,3 191,3 40,9 191,5 41,5 191,7 42,2 193,3 44,9 5 / 3,9 210,3 39,1 210,8 42,2 211,0 44,2 211,1 44,9 211,2 45,6 211,3 46,3 211,7 49,3 7 / 6,1 220,0 40,8 220,4 44,1 220,6 46,2 220,7 47,0 220,7 47,7 220,7 48,5 220,9 51,6 10 / 8,2 229,7 42,7 229,7 46,1 229,7 48,3 229,7 49,1 229,7 49,9 229,7 50,7 229,7 54,0 15 / 13 253,7 47,4 250,9 51,1 250,0 53,6 249,9 54,4 249,8 55,3 249,8 56,2 250,5 59,9 Ta = Outside air temperature (°C) DB = dry bulb WB = wet bulb kWt = Heating capacity (kW) with coils free of ice kWe = Compressor power input in kW Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) not all thermal yields take into account the heat dissipated by the fan motors 20 PACKAGED 362 - 904 AIR FLOW: REDUCED HEATING PERFORMANCE Size 804 904 Ta (°C) DB/WB RETURN AIR TEMPERATURE (D.B.) 10 15 18 19 20 21 25 kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe -5 / -5,4 208,8 37,4 207,5 39,8 208,1 41,5 208,5 42,1 209,0 42,8 209,7 43,4 213,4 46,3 0 / -0,6 232,2 40,4 231,4 43,3 232,2 45,3 232,7 46,0 233,3 46,8 234,0 47,6 238,0 50,9 5 / 3,9 258,2 44,2 257,2 47,5 257,3 49,7 257,5 50,5 257,8 51,3 258,1 52,1 260,0 55,7 7 / 6,1 272,5 46,4 271,0 49,9 270,5 52,2 270,4 53,0 270,3 53,8 270,3 54,7 270,5 58,1 10 / 8,2 286,9 48,8 284,9 52,4 283,6 54,8 283,1 55,6 282,7 56,4 282,2 57,2 280,3 60,6 15 / 13 323,3 54,9 319,3 59,0 315,5 61,3 313,9 62,1 312,2 62,9 310,4 63,6 302,0 66,6 -5 / -5,4 230,1 42,5 229,3 44,9 229,9 46,7 230,3 47,3 230,7 48,0 231,3 48,7 234,3 51,7 0 / -0,6 257,1 45,8 255,3 48,7 255,1 50,8 255,2 51,5 255,4 52,3 255,6 53,1 257,3 56,4 5 / 3,9 283,9 49,8 283,1 53,4 282,8 55,8 282,7 56,6 282,6 57,4 282,5 58,3 282,4 61,9 7 / 6,1 297,7 52,0 297,9 56,1 297,7 58,6 297,5 59,5 297,3 60,3 297,1 61,2 295,9 64,9 10 / 8,2 311,1 54,4 312,8 58,8 312,7 61,5 312,5 62,4 312,3 63,4 311,9 64,3 309,6 68,0 15 / 13 343,1 60,4 349,5 66,0 350,3 69,1 350,1 70,1 349,7 71,1 349,0 72,1 343,8 75,9 Ta = Outside air temperature (°C) DB = dry bulb WB = wet bulb kWt = Heating capacity (kW) with coils free of ice kWe = Compressor power input in kW Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) not all thermal yields take into account the heat dissipated by the fan motors INTEGRATED HEATING CAPACITIES Air temperature external exchanger inlet °C (D.B. / W.B.) Heating capacity multiplication coefficient -5 / -5.4 0,89 0 / -0.6 0,88 5 / 3.9 0,94 OTHERS 1 BT08A006GB-03 To obtain the integrated heating capacities (the real heating capacity considering the defrost cycles too), multiply the kWt value in the heating performance tables by the following coefficient. DB = dry bulb WB = wet bulb In case of below zero air ambient temperature with a long period of heat pump operating mode it is necessary to help the evacuation of the water produced during the defrost cycle; this to avoid the formation of ice in the unit basement. Pay attention that the evacuation will not create inconveniences to things or persons. 21 PACKAGED 362 - 904 AIR FLOW: HIGH Size 362 402 452 464 524 604 704 804 904 6666 570 7222 570 7500 450 9722 570 10833 510 11667 570 12222 570 14722 570 15556 570 AIR HANDLING SECTION FANS (OUTLET) Air flow Max outside static pressure l/s Pa COOLING PERFORMANCE Size Ta (°C) DB/WB 35 40 kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs 16 / 12 105,9 21,0 78,1 106,3 23,1 76,1 106,6 24,0 75,2 107,4 25,4 74,0 109,3 27,9 71,9 111,4 30,0 70,2 20 / 14 110,1 21,4 89,8 110,1 23,6 87,4 110,3 24,5 86,5 110,9 25,9 85,0 112,3 28,4 82,6 114,1 30,5 80,7 24 / 17 116,3 22,2 95,8 116,2 24,3 93,2 116,3 25,2 92,2 116,6 26,7 90,6 117,7 29,2 88,1 118,9 31,4 86,0 26 / 19 120,4 22,7 95,2 120,5 24,8 92,7 120,6 25,7 91,7 120,9 27,2 90,2 121,7 29,8 87,7 122,6 32,1 85,7 27 / 19,5 121,4 22,8 98,1 121,6 24,9 95,7 121,7 25,8 94,7 122,0 27,3 93,2 122,8 29,9 90,8 123,7 32,3 88,8 28 / 21 124,5 23,2 93,7 124,9 25,3 91,5 125,1 26,2 90,6 125,5 27,7 89,2 126,2 30,4 87,0 16 / 12 117,0 24,4 80,0 117,6 26,8 78,0 118,0 27,7 77,2 118,9 29,3 76,0 120,7 31,9 74,0 122,6 34,1 72,4 20 / 14 120,5 25,1 97,8 121,2 27,6 95,4 121,6 28,6 94,4 122,2 30,1 93,0 123,5 32,7 90,6 124,6 34,9 88,6 24 / 17 127,2 26,0 100,9 127,2 28,4 98,3 127,4 29,4 97,3 127,8 30,9 95,7 128,8 33,6 93,1 130,0 35,7 91,1 26 / 19 132,6 26,4 102,1 131,6 28,8 99,7 131,6 29,7 98,7 131,9 31,3 97,3 133,2 33,9 94,8 135,2 36,1 92,9 27 / 19,5 134,1 26,5 106,9 132,8 28,8 104,6 132,7 29,8 103,7 132,9 31,3 102,3 134,5 34,0 99,9 136,7 36,2 98,1 28 / 21 138,8 26,7 111,3 136,4 28,9 109,3 136,0 29,9 108,5 136,2 31,4 107,3 138,3 34,1 105,3 141,6 36,4 103,7 16 / 12 125,1 28,1 82,2 123,9 31,1 78,8 123,9 32,4 77,5 124,5 34,2 75,5 127,0 37,3 72,1 130,3 39,7 69,4 20 / 14 129,2 28,8 102,5 129,7 31,6 99,5 130,0 32,8 98,2 130,4 34,6 96,4 131,4 37,8 93,3 132,4 40,5 90,9 24 / 17 136,2 29,9 108,5 137,2 32,6 105,7 137,5 33,7 104,6 137,7 35,5 102,9 137,6 38,8 100,2 137,2 41,6 97,9 26 / 19 141,5 30,6 106,7 141,4 33,4 104,1 141,4 34,6 103,0 141,4 36,4 101,4 141,5 39,6 98,7 141,5 42,3 96,6 27 / 19,5 142,8 30,7 109,9 142,4 33,6 107,2 142,3 34,8 106,2 142,2 36,6 104,6 142,4 39,8 101,9 142,8 42,5 99,8 28 / 21 147,1 31,2 106,7 144,9 34,3 104,1 144,5 35,5 103,0 144,2 37,4 101,4 145,1 40,5 98,8 146,8 43,0 96,7 16 / 12 142,2 26,4 97,7 144,2 28,9 93,9 145,1 29,9 92,4 146,4 31,5 90,1 148,7 34,4 86,3 150,6 36,8 83,3 20 / 14 146,8 27,3 124,9 149,0 29,9 122,1 149,8 30,9 120,9 151,0 32,5 119,2 152,9 35,4 116,3 154,4 37,8 114,0 24 / 17 154,8 28,4 123,9 156,4 31,0 121,4 157,0 32,1 120,4 157,9 33,7 118,9 159,5 36,5 116,3 160,7 38,9 114,3 26 / 19 160,8 29,0 125,4 161,5 31,6 122,5 161,9 32,7 121,3 162,6 34,3 119,6 163,9 37,1 116,6 165,2 39,4 114,3 27 / 19,5 162,4 29,1 132,1 162,8 31,7 128,9 163,1 32,8 127,7 163,7 34,4 125,8 165,0 37,3 122,7 166,4 39,6 120,2 28 / 21 167,3 29,4 144,5 166,8 32,1 140,6 166,9 33,1 139,1 167,2 34,8 136,8 168,4 37,6 132,9 16 / 12 158,6 32,6 115,3 159,7 36,2 111,5 160,1 37,7 109,9 160,6 40,0 107,7 161,4 44,0 103,9 161,8 47,4 100,8 20 / 14 164,9 33,5 135,5 165,2 37,1 132,5 165,3 38,6 131,2 165,6 40,8 129,4 166,2 44,7 126,3 166,8 47,8 123,9 24 / 17 174,1 34,6 143,8 173,9 38,2 140,9 173,9 39,7 139,7 173,8 41,9 138,0 173,8 45,7 135,0 173,9 48,8 132,7 26 / 19 180,2 35,2 143,2 180,1 38,7 139,7 180,0 40,2 138,3 179,7 42,5 136,2 179,1 46,4 132,7 178,4 49,7 129,8 27 / 19,5 181,7 35,3 148,3 181,7 38,8 144,6 181,6 40,3 143,1 181,2 42,6 140,9 180,4 46,6 137,1 179,5 49,9 134,1 28 / 21 186,2 35,6 144,0 186,5 39,1 139,4 186,4 40,6 137,5 186,0 42,9 134,8 184,5 47,1 130,2 16 / 12 183,8 36,4 125,7 185,6 40,3 121,6 186,3 42,0 120,0 187,1 44,4 117,5 188,3 48,7 113,4 189,0 52,3 110,2 20 / 14 190,4 37,3 154,3 191,6 41,2 150,1 192,1 42,8 148,4 192,8 45,3 145,9 194,0 49,7 141,7 195,0 53,3 138,3 24 / 17 200,9 38,5 166,0 201,3 42,3 161,8 201,6 44,0 160,2 202,1 46,5 157,7 203,4 50,9 153,6 204,7 54,6 150,2 26 / 19 208,3 39,2 164,0 208,3 43,1 160,1 208,5 44,7 158,5 208,9 47,2 156,2 210,2 51,5 152,2 211,7 55,2 149,1 27 / 19,5 210,2 39,4 169,0 210,1 43,2 165,2 210,3 44,9 163,6 210,7 47,3 161,3 212,0 51,7 157,5 213,5 55,4 154,4 28 / 21 216,0 39,9 161,5 215,7 43,7 157,9 215,8 45,3 156,5 216,2 47,8 154,3 217,5 52,1 150,8 16 / 12 201,3 43,8 140,8 202,2 48,2 135,1 202,8 50,0 132,7 204,0 53,0 129,3 206,9 58,4 123,5 209,8 63,0 118,9 20 / 14 209,8 44,8 167,2 209,7 49,3 162,2 210,0 51,2 160,2 210,6 54,2 157,2 212,3 59,5 152,3 214,4 64,0 148,3 24 / 17 222,3 46,3 176,9 221,3 50,9 172,6 221,2 52,8 170,8 221,3 55,9 168,3 222,4 61,2 164,0 224,0 65,8 160,5 26 / 19 230,5 47,2 174,9 229,1 51,9 170,7 229,0 53,8 169,0 229,1 56,9 166,5 230,4 62,4 162,3 232,3 67,1 158,9 27 / 19,5 232,5 47,4 180,2 231,1 52,1 176,0 231,0 54,1 174,3 231,1 57,2 171,7 232,5 62,7 167,5 234,6 67,4 164,1 28 / 21 238,5 48,1 174,0 237,1 52,8 169,6 237,0 54,8 167,8 237,4 58,0 165,2 239,3 63,6 160,7 242,0 68,5 157,2 Ta = ambient air temperature D.B/W.B DB = dry bulb WB = wet bulb kWf = Cooling capacity in kW kWe = Compressor power input in kW kWs = sensible cooling capacity (kW) Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) the cooling capacities have not accounted for the heat dissipation of the centrifugal fan motors. 22 44 kWf 524 BT08A006GB-03 32 kWs 464 704 30 kWe 402 604 25 kWf 362 452 EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) PACKAGED 362 - 904 AIR FLOW: HIGH COOLING PERFORMANCE Size 804 904 Ta (°C) DB/WB EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) 25 30 32 35 40 44 kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs kWf kWe kWs 16 / 12 247,6 46,9 128,3 249,2 51,7 121,9 249,9 53,7 119,4 250,9 56,8 115,6 252,6 62,3 109,2 253,9 67,0 104,1 20 / 14 256,8 47,9 202,3 257,5 52,7 196,2 258,0 54,8 193,7 258,8 57,9 190,0 260,6 63,4 183,9 262,5 68,1 179,0 24 / 17 271,2 49,3 224,9 271,7 54,2 219,1 271,9 56,2 216,8 272,3 59,3 213,3 273,2 64,8 207,4 274,1 69,4 202,8 26 / 19 281,2 50,2 220,2 282,2 55,0 214,5 282,4 57,0 212,3 282,5 60,1 208,9 282,0 65,5 203,2 281,0 70,0 198,7 27 / 19,5 283,8 50,5 227,0 285,0 55,2 221,4 285,2 57,2 219,1 285,1 60,3 215,8 284,2 65,6 210,2 282,7 70,1 205,7 28 / 21 291,5 51,1 220,3 293,7 55,8 214,8 293,9 57,7 212,6 293,5 60,7 209,3 291,0 66,0 203,9 16 / 12 267,8 53,9 192,9 269,4 59,2 185,9 270,1 61,5 183,1 271,3 65,1 178,9 273,6 71,3 171,9 275,6 76,7 166,3 20 / 14 277,7 55,2 223,4 277,7 60,7 217,0 278,0 63,0 214,4 278,9 66,5 210,5 281,2 72,7 204,1 283,8 77,8 199,0 24 / 17 293,4 56,8 239,1 292,3 62,6 233,2 292,2 64,9 230,8 292,5 68,5 227,2 294,1 74,7 221,3 296,3 79,7 216,5 26 / 19 304,4 57,6 237,9 303,4 63,5 232,0 303,3 65,9 229,7 303,2 69,6 226,2 303,8 76,0 220,3 304,8 81,2 215,6 27 / 19,5 307,2 57,8 246,0 306,4 63,7 240,1 306,2 66,2 237,8 306,1 69,9 234,2 306,4 76,3 228,3 307,0 81,6 223,6 28 / 21 315,9 58,2 234,9 315,7 64,3 228,9 315,5 66,8 226,5 315,2 70,6 222,9 314,3 77,2 216,9 313,5 82,8 212,2 BT08A006GB-03 Ta = ambient air temperature D.B/W.B DB = dry bulb WB = wet bulb kWf = Cooling capacity in kW kWe = Compressor power input in kW kWs = sensible cooling capacity (kW) Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) the cooling capacities have not accounted for the heat dissipation of the centrifugal fan motors. 23 PACKAGED 362 - 904 AIR FLOW: HIGH Size 362 402 452 464 524 604 704 804 904 6666 570 7222 570 7500 450 9722 570 10833 510 11667 570 12222 570 14722 570 15556 570 AIR HANDLING SECTION FANS (OUTLET) Air flow Max outside static pressure l/s Pa HEATING PERFORMANCE Size Ta (°C) DB/WB RETURN AIR TEMPERATURE (D.B.) 10 kWt 15 kWe -5 / -5,4 18 19 20 21 25 kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe 92,2 16,2 92,4 16,8 92,5 17,0 92,6 17,2 92,6 17,5 92,8 18,4 0 / -0,6 102,2 16,3 101,9 17,3 102,0 18,0 102,1 18,2 102,2 18,5 102,4 18,7 103,1 19,9 5 / 3,9 111,3 17,3 111,7 18,5 112,0 19,3 112,1 19,6 112,3 19,9 112,4 20,2 113,1 21,5 362 7 / 6,1 115,5 17,9 116,7 19,2 117,2 20,1 117,4 20,4 117,5 20,7 117,7 21,0 118,1 22,3 10 / 8,2 119,4 18,4 121,5 19,9 122,4 20,9 122,6 21,2 122,7 21,5 122,8 21,8 122,9 23,2 15 / 13 127,6 19,7 133,2 21,7 134,9 22,8 135,2 23,2 135,4 23,6 135,4 24,0 134,2 25,4 101,9 18,6 102,8 19,4 103,1 19,6 103,4 19,9 103,7 20,2 105,2 21,4 -5 / -5,4 402 0 / -0,6 112,4 18,6 113,3 19,9 113,9 20,8 114,2 21,1 114,4 21,4 114,7 21,7 115,8 23,1 5 / 3,9 123,8 20,0 124,5 21,4 125,0 22,4 125,2 22,7 125,4 23,1 125,6 23,4 126,5 24,9 7 / 6,1 129,5 20,7 130,2 22,3 130,7 23,3 130,9 23,6 131,1 24,0 131,3 24,4 132,0 26,0 10 / 8,2 135,1 21,4 135,8 23,1 136,3 24,2 136,5 24,6 136,6 25,0 136,8 25,4 137,5 27,0 15 / 13 148,1 23,3 149,0 25,3 149,5 26,5 149,7 27,0 149,8 27,4 150,0 27,8 150,5 29,6 113,4 21,6 114,7 22,4 115,3 22,8 116,0 23,1 116,8 23,4 120,7 25,0 0 / -0,6 123,6 21,5 124,6 22,9 125,7 23,9 126,1 24,3 126,5 24,6 127,0 25,0 129,3 26,7 5 / 3,9 135,1 22,9 136,2 24,6 136,9 25,7 137,2 26,1 137,5 26,5 137,8 26,9 139,1 28,6 7 / 6,1 141,3 23,7 142,2 25,5 142,8 26,7 143,0 27,1 143,2 27,5 143,5 27,9 144,4 29,7 10 / 8,2 147,4 24,6 148,1 26,5 148,6 27,7 148,8 28,1 149,0 28,6 149,1 29,0 149,8 30,9 15 / 13 162,5 26,9 162,6 29,0 162,8 30,4 162,8 30,8 162,9 31,3 163,0 31,8 163,5 33,8 128,8 20,9 129,8 21,9 129,7 22,2 129,3 22,4 128,6 22,7 123,6 23,7 0 / -0,6 133,6 20,3 135,5 22,0 137,0 23,1 137,5 23,5 138,1 23,9 138,6 24,3 141,1 25,9 5 / 3,9 145,6 21,8 146,4 23,5 148,0 24,7 148,7 25,2 149,5 25,6 150,4 26,1 155,0 28,1 -5 / -5,4 452 -5 / -5,4 464 7 / 6,1 152,0 22,6 153,3 24,4 154,9 25,7 155,6 26,2 156,3 26,6 157,1 27,1 160,9 29,2 10 / 8,2 158,4 23,4 160,9 25,4 162,4 26,7 162,9 27,2 163,4 27,7 163,9 28,2 165,9 30,2 15 / 13 174,2 25,3 181,9 28,1 183,0 29,5 182,8 30,0 182,3 30,5 181,5 30,9 175,4 32,5 130,0 24,3 131,1 25,3 132,1 25,8 133,3 26,2 134,8 26,7 143,5 28,8 -5 / -5,4 524 0 / -0,6 150,2 24,6 149,5 26,2 150,3 27,4 150,8 27,9 151,3 28,3 152,0 28,8 155,8 30,8 5 / 3,9 166,2 26,3 166,8 28,3 167,3 29,7 167,5 30,1 167,8 30,6 168,0 31,1 169,3 33,2 7 / 6,1 174,1 27,3 174,8 29,4 175,3 30,8 175,5 31,3 175,6 31,8 175,8 32,3 176,5 34,5 10 / 8,2 181,7 28,2 182,3 30,5 182,7 32,0 182,9 32,5 183,0 33,1 183,2 33,6 183,9 35,8 15 / 13 199,3 30,7 198,6 33,3 199,0 34,9 199,2 35,5 199,6 36,1 199,9 36,7 202,1 39,2 158,4 27,4 160,8 28,7 161,4 29,2 161,9 29,7 162,3 30,1 163,0 31,9 BT08A006GB-03 -5 / -5,4 0 / -0,6 169,4 26,9 176,4 29,5 178,5 31,0 178,8 31,4 179,0 31,9 178,9 32,4 177,0 34,2 5 / 3,9 187,6 29,1 193,9 31,8 195,5 33,3 195,6 33,8 195,6 34,3 195,4 34,8 192,7 36,8 7 / 6,1 197,3 30,3 202,6 33,0 203,9 34,6 204,0 35,1 204,0 35,6 203,8 36,2 201,3 38,3 10 / 8,2 207,0 31,5 211,1 34,2 212,1 35,8 212,2 36,4 212,1 36,9 212,0 37,5 210,1 39,7 15 / 13 230,9 34,4 230,8 37,1 231,0 38,9 231,2 39,5 231,3 40,1 231,5 40,8 232,3 43,5 176,2 33,0 175,4 34,2 175,8 34,6 176,4 35,1 177,4 35,6 184,0 38,0 0 / -0,6 195,5 33,1 196,0 35,3 196,6 36,8 196,9 37,3 197,1 37,9 197,4 38,4 198,8 40,7 5 / 3,9 212,4 35,3 215,3 38,0 216,3 39,7 216,6 40,3 216,7 40,9 216,8 41,5 216,6 44,0 7 / 6,1 222,6 36,6 224,9 39,5 225,9 41,3 226,1 41,9 226,3 42,6 226,5 43,2 226,7 45,9 10 / 8,2 233,4 38,0 234,3 41,0 235,0 42,9 235,3 43,6 235,5 44,3 235,8 45,0 237,2 47,9 15 / 13 262,4 41,8 256,1 44,7 255,6 46,9 256,0 47,7 256,7 48,5 257,6 49,3 264,2 53,0 604 -5 / -5,4 704 24 Ta = Outside air temperature (°C) DB = dry bulb WB = wet bulb kWt = Heating capacity (kW) with coils free of ice kWe = Compressor power input in kW Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) not all thermal yields take into account the heat dissipated by the fan motors PACKAGED 362 - 904 AIR FLOW: HIGH HEATING PERFORMANCE Size Ta (°C) DB/WB RETURN AIR TEMPERATURE (D.B.) 10 kWt 15 kWe -5 / -5,4 804 19 20 21 25 kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe kWt kWe 212,0 36,3 213,9 37,8 214,5 38,3 215,1 38,8 215,7 39,3 217,9 41,6 0 / -0,6 240,4 36,7 241,0 39,1 241,6 40,7 241,8 41,2 242,0 41,8 242,2 42,4 243,4 44,9 5 / 3,9 267,3 39,3 267,0 42,1 267,0 43,9 267,0 44,5 267,1 45,1 267,2 45,8 267,8 48,6 7 / 6,1 279,5 40,7 279,2 43,6 279,2 45,6 279,3 46,2 279,4 46,9 279,5 47,6 280,0 50,5 10 / 8,2 290,4 42,1 290,6 45,2 290,8 47,3 290,9 48,0 291,0 48,7 291,1 49,5 291,8 52,5 15 / 13 313,2 45,4 315,6 49,2 316,8 51,6 317,2 52,4 317,5 53,2 317,9 54,1 319,1 57,5 233,6 41,8 235,4 43,3 236,3 43,8 237,2 44,4 238,2 45,0 243,4 47,6 0 / -0,6 260,6 42,1 262,3 44,7 263,6 46,4 264,1 47,0 264,6 47,7 265,1 48,3 267,5 51,2 5 / 3,9 289,7 45,0 290,5 48,0 291,1 50,0 291,3 50,7 291,5 51,5 291,7 52,2 292,5 55,3 7 / 6,1 304,9 46,7 304,8 49,9 304,9 52,0 305,0 52,8 305,0 53,5 305,1 54,3 305,7 57,6 10 / 8,2 320,1 48,4 318,7 51,9 318,3 54,1 318,3 54,9 318,3 55,7 318,3 56,5 318,8 60,0 15 / 13 357,1 53,1 351,6 56,9 349,9 59,4 349,6 60,3 349,4 61,2 349,4 62,1 350,7 65,9 -5 / -5,4 904 18 Ta = Outside air temperature (°C) DB = dry bulb WB = wet bulb kWt = Heating capacity (kW) with coils free of ice kWe = Compressor power input in kW Performance data are referred to operation with 30% of fresh air intake and same amount of air exhaust. (construction configuration C) not all thermal yields take into account the heat dissipated by the fan motors INTEGRATED HEATING CAPACITIES Air temperature external exchanger inlet °C (D.B. / W.B.) Heating capacity multiplication coefficient -5 / -5.4 0,89 0 / -0.6 0,88 5 / 3.9 0,94 OTHERS 1 To obtain the integrated heating capacities (the real heating capacity considering the defrost cycles too), multiply the kWt value in the heating performance tables by the following coefficient. DB = dry bulb WB = wet bulb In case of below zero air ambient temperature with a long period of heat pump operating mode it is necessary to help the evacuation of the water produced during the defrost cycle; this to avoid the formation of ice in the unit basement. Pay attention that the evacuation will not create inconveniences to things or persons. PRESSURE DROPS OF OPTIONAL COMPONENTS SIZE PRESSURE DROP CHW2 2 rows hot water coil GH03 Gas re-heating module from 96 kW GH05 Gas re-heating module from 150 kW GH06 Gas re-heating module from 200 kW GH08 Gas re-heating module from 300 kW CPHG Hot gas re-heating coil F7 High efficiency F7 air filter FES High efficiency H10 electrostatic air filter HWS Water to waste evaporating wet-deck humidifier Pa Pa Pa Pa Pa Pa 1 Pa Pa Pa 362 402 452 464 524 604 704 804 904 28 90 90 90 20 140 40 21 32 95 95 95 22 160 40 23 35 100 100 100 24 180 40 25 30 85 85 85 120 18 100 40 18 36 90 90 90 130 20 120 40 20 42 95 95 95 140 22 140 40 22 50 100 100 100 150 24 160 40 24 47 95 95 140 22 140 40 21 55 100 100 150 24 160 40 23 BT08A006GB-03 To obtain the performance required of the supply fans, add the value of desired static pressure to the value in Pa shown in the table of pressure drops of the optional components. The values shown are to be considered approximate for units operating power in normal use with standard air flow rate. (1)Pressure drops with filters with average dirtiness 25 PACKAGED 362 - 904 PERFORMANCES OF SUPPLY AIR FANS EXTERNAL STATIC PRESSURE (Pa) Air flow l/s AIR FLOW: STANDARD 120 150 180 210 240 270 300 330 360 390 420 450 510 570 5555 5555 5555 5555 5555 5555 5555 5555 5555 5555 5555 5555 5555 5555 362 Fan RPM rpm 718 742 766 790 814 837 860 883 905 927 949 971 1013 1054 Motor shaft input power kW 4,96 5,22 5,48 5,75 6,02 6,29 6,57 6,85 7,14 7,42 7,71 8,01 8,6 9,2 Sound pressure level dB 86 87 87 87 87 88 88 88 88 89 89 89 90 91 F.L.I. - Single supply fan kW 7,5 7,5 7,5 7,5 7,5 7,5 7,5 9 9 9 9 9 11 11 A 14,9 14,9 14,9 14,9 14,9 14,9 14,9 19,0 19,0 19,0 19,0 19,0 21,0 21,0 F.L.A. Transmission code (fan) PF 2A 250 PF 2A 224 Transmission code (motor) Air flow PV 2A 177 402 l/s 6111 6111 6111 6111 6111 6111 6111 6111 6111 6111 6111 6111 6111 6111 Fan RPM rpm 767 790 812 834 856 878 899 920 941 962 982 1003 1042 1081 Motor shaft input power kW 6,32 6,6 6,88 7,17 7,46 7,76 8,06 8,36 8,67 8,97 9,28 9,6 10,24 10,9 Sound pressure level dB 88 89 89 89 89 89 89 90 90 90 91 91 91 92 F.L.I. - Single supply fan kW 7,5 7,5 7,5 7,5 9 9 9 9 11 11 11 11 11 11 A 14,9 14,9 14,9 14,9 19,0 19,0 19,0 19,0 21,0 21,0 21,0 21,0 21,0 21,0 F.L.A. Transmission code (fan) PF 2A 250 Transmission code (motor) Air flow PF 2A 236 PF 2A 224 PV 2A 156 PV 2A 177 452 l/s 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 Fan RPM rpm 820 841 862 882 902 922 942 962 982 1001 1020 1040 1077 1114 Motor shaft input power kW 7,95 8,26 8,56 8,87 9,19 9,51 9,83 10,15 10,48 10,81 11,14 11,47 11,65 12,3 Sound pressure level dB 90 90 90 91 91 91 91 91 92 92 92 92 93 93 F.L.I. - Single supply fan kW 9 9 9 9 11 11 11 11 11 11 15 15 15 15 A 19,0 19,0 19,0 19,0 21,0 21,0 21,0 21,0 21,0 21,0 28,5 28,5 28,5 28,5 F.L.A. Transmission code (fan) PF 2A 280 PF 2A 250 Transmission code (motor) Air flow PF 2A 315 PV 2A 177 PF 2A 224 PF 2A 236 464 l/s 8056 8056 8056 8056 8056 8056 8056 8056 8056 8056 8056 8056 8056 8056 Fan RPM rpm 680 705 730 756 781 806 831 856 881 905 930 954 1002 1049 Motor shaft input power kW 6,9 7,3 7,7 8,2 8,6 9,1 9,5 10 10,5 11,1 11,6 12,2 12,7 13,8 Sound pressure level dB 86 86 86 87 87 88 88 89 89 90 90 91 92 93 F.L.I. - Single supply fan kW 9 9 9 9 9 11 11 11 11 15 15 15 15 15 A 19,0 19,0 19,0 19,0 19,0 21,0 21,0 21,0 21,0 28,5 28,5 28,5 28,5 28,5 F.L.A. Transmission code (fan) PF 2A 315 PF 2A 280 Transmission code (motor) Air flow PF3A300 PV 2A 177 PF 3A 280 PF 3A 180 PF3A300 PF3A280 PF 3A 200 524 l/s 9028 9028 9028 9028 9028 9028 9028 9028 9028 9028 9028 9028 9028 9028 Fan RPM rpm 731 754 776 799 821 844 866 889 911 934 956 978 1022 1065 Motor shaft input power kW 9,1 9,5 10 10,4 10,9 11,4 11,9 12,2 12,4 12,9 13,4 13,9 15,1 16,2 Sound pressure level dB 88 88 89 89 89 89 90 90 91 91 92 92 93 93 F.L.I. - Single supply fan kW 11 11 11 11 15 15 15 15 15 15 15 15 18,5 18,5 A 21.0 21,0 21,0 21,0 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 35,0 35,0 F.L.A. Transmission code (fan) PF 2A 300 Transmission code (motor) Air flow PF 3A 300 PV 2A 177 PF 3A 170 PF 3A 180 PF 3A 280 PF 3A 190 PF 3A 200 604 l/s 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 Fan RPM rpm 792 812 833 853 873 894 914 935 955 975 995 1016 1056 - Motor shaft input power kW 11,9 12,1 12,3 12,8 13,3 13,7 14,2 14,8 15,3 15,8 16,4 16,9 18,1 - Sound pressure level dB 90 90 91 91 91 91 92 92 92 93 93 93 94 - F.L.I. - Single supply fan kW 15 15 15 15 15 15 15 15 18,5 18,5 18,5 18,5 18,5 - A 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 35,0 35,0 35,0 35,0 35,0 - F.L.A. Transmission code (fan) PF 3A 315 Transmission code (motor) Air flow 704 PF 3A 170 l/s 11111 11111 PF 3A 180 11111 11111 PF 3A 300 PF 3A 190 11111 PF 3A 280 PF 3A 200 11111 11111 - 11111 11111 11111 11111 11111 11111 11111 Fan RPM rpm 855 873 891 910 928 946 965 983 1001 1020 1038 1056 1093 1129 Motor shaft input power kW 14,9 15,4 15,9 16,4 16,9 17,4 18 18,5 19 19,6 20,2 20,8 21,9 23,2 Sound pressure level dB 93 93 93 93 93 94 94 94 94 94 94 95 95 96 F.L.I. - Single supply fan kW 18,5 18,5 18,5 18,5 18,5 18,5 18,5 22 22 22 22 22 30 30 A 35,0 35,0 35,0 35,0 35,0 35,0 35,0 41,0 41,0 41,0 41,0 41,0 57,0 57,0 F.L.A. Transmission code (fan) PF3A300 Transmission code (motor) Air flow 804 BT08A006GB-03 PF 2A 236 PV 2A 156 PF 3A 280 PF 3A 170 PF 3A 300 PF 3A 180 PF 3A 280 PF 3A 300 PF 3A 200 PF 3A 224 l/s 12500 12500 12500 12500 12500 12500 12500 12500 12500 12500 12500 12500 12500 12500 Fan RPM rpm 742 761 780 798 816 835 853 871 889 907 925 943 978 1012 Motor shaft input power kW 14,2 14,7 15,2 15,8 16,4 16,9 17,5 18,1 18,7 19,3 20 20,6 21,9 23,2 Sound pressure level dB 90 90 91 91 91 91 92 92 92 92 92 93 93 94 F.L.I. - Single supply fan kW 18,5 18,5 18,5 18,5 18,5 18,5 18,5 18,5 22 22 22 22 30 30 A 35,0 35,0 35,0 35,0 35,0 35,0 35,0 35,0 41,0 41,0 41,0 41,0 57,0 57,0 F.L.A. Transmission code (fan) PF 3A 355 Transmission code (motor) Air flow PF 3A 180 PF 3A 315 PF 3A 190 PF 3A 300 PF 3A 180 PF 5A 315 PF 3A 190 PF 5A 224 904 l/s 13889 13889 13889 13889 13889 13889 13889 13889 13889 13889 13889 13889 13889 13889 Fan RPM rpm 794 811 828 845 862 878 895 911 928 944 961 977 1009 1041 Motor shaft input power kW 18,3 18,9 19,5 20,1 20,7 21,3 21,9 22,5 23,2 23,8 24,5 25,2 26,5 27,9 Sound pressure level dB 93 93 93 93 93 93 93 94 94 94 94 94 95 95 F.L.I. - Single supply fan kW 22 22 22 22 22 22 30 30 30 30 30 30 30 30 A 41,0 41,0 41,0 41,0 41,0 41,0 57,0 57,0 57,0 57,0 57,0 57,0 57,0 57,0 F.L.A. Transmission code (fan) PF 3A 355 PF 3A 315 PF 5A 355 Transmission code (motor) PF 3A 200 PF 3A 190 PF 5A 224 PF 5A 315 PF 5A 200 PF 5A 224 The performance takes into account the pressure drops in the unit (pressure drops in treatment coil, standard filters, etc.). To determine the performance required by the fans, it is necessary to add the desired usable static pressure to the pressure drops of any accessories (e.g. hot water coils, gas module, additional filter section, etc.). The value of absorbed electrical power has already been corrected by a factor that takes into account the losses in transmission and a minimum tolerance on the number of revs of the fan. 26 PACKAGED 362 - 904 INTAKE AIR FLOW: STANDARD AIR FLOW PERFORMANCES OF RETURN AIR FANS EXTERNAL STATIC PRESSURE (Pa) l/s 60 90 120 150 180 210 240 270 300 330 360 390 420 450 4444 4444 4444 4444 4444 4444 4444 4444 4444 4444 4444 4444 4444 4444 362 Fan RPM rpm 472 504 536 567 598 628 658 687 715 743 770 796 822 848 Motor shaft input power kW 1,91 2,1 2,3 2,5 2,71 2,92 3,14 3,36 3,58 3,81 4,05 4,28 4,52 4,76 Sound pressure level dB 81 81 81 82 82 82 82 83 83 84 84 84 85 85 F.L.I. - Single supply fan kW 3 3 3 3 3 3 4 4 4 4 5,5 5,5 5,5 5,5 A 6,5 6,5 6,5 6,5 6,5 6,5 8,3 8,3 8,3 8,3 11,2 11,2 11,2 11,2 F.L.A. Transmission code (fan) PF 1A 400 PF 1A 315 Transmission code (motor) Air flow PF 1A 280 PF 1A 400 PV 1A 156 PV 1A 250 402 l/s 4888 4888 4888 4888 4888 4888 4888 4888 4888 4888 4888 4888 4888 Fan RPM rpm 510 539 568 597 626 653 681 708 735 761 786 812 836 861 Motor shaft input power kW 2,47 2,68 2,89 3,11 3,33 3,56 3,79 4,03 4,27 4,52 4,76 5,02 5,27 5,53 Sound pressure level dB 83 83 83 84 84 84 84 84 85 85 85 86 86 86 F.L.I. - Single supply fan kW 3 3 3 4 4 4 4 5,5 5,5 5,5 5,5 5,5 5,5 7,5 A 6,5 6,5 6,5 8,3 8,3 8,3 8,3 11,2 11,2 11,2 11,2 11,2 11,2 14,9 F.L.A. Transmission code (fan) PF 1A 355 PF 1A 315 Transmission code (motor) Air flow PF 1A 450 4888 PF 1A 400 PV 1A 156 PV 1A 250 452 l/s 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 Fan RPM rpm 548 575 602 628 655 681 706 732 757 781 805 829 853 876 Motor shaft input power kW 3,14 3,36 3,59 3,82 4,06 4,31 4,55 4,81 5,06 5,32 5,59 5,86 6,13 6,4 Sound pressure level dB 85 85 85 85 85 86 86 86 86 86 87 87 87 88 F.L.I. - Single supply fan kW 4 4 4 5,5 5,5 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 7,5 A 8,3 8,3 8,3 11,2 11,2 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 14,9 F.L.A. Transmission code (fan) PF 1A 355 Transmission code (motor) Air flow PF 1A 315 PF 1A 450 PF 1A 400 PV 1A 156 PV 1A 250 464 l/s - 6444 6444 6444 6444 6444 6444 6444 6444 6444 6444 6444 6444 - Fan RPM rpm - 507 539 571 602 634 665 696 727 757 787 817 846 - Motor shaft input power kW - 3,1 3,4 3,7 4,1 4,4 4,8 5,2 5,6 6 6,5 6,9 7,4 - Sound pressure level dB - 80 80 81 82 82 83 84 85 85 86 87 87 - F.L.I. - Single supply fan kW - 4 4 4 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 7,5 - 8,3 8,3 8,3 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 14,9 - F.L.A. A Transmission code (fan) - PF 1A 315 Transmission code (motor) - PV 1A 139 Air flow PF 2A 300 - PV 2A 156 PV 2A 177 - 524 l/s 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 - Fan RPM rpm 517 546 574 608 630 658 686 715 742 770 798 825 852 - Motor shaft input power kW 3,8 4,1 4,5 4,8 5,2 5,5 5,9 6,3 6,7 7,2 7,6 8,1 8,6 - Sound pressure level dB 82 83 83 83 84 84 84 85 86 86 87 88 88 - F.L.I. - Single supply fan kW 5,5 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 7,5 9 9 9 - A 11,2 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 14,9 19,0 19,0 19,0 - F.L.A. Transmission code (fan) PF 2A 400 PF 2A 355 Transmission code (motor) Air flow PF 2A 300 PF 2A 280 PV 2A 164 - PV 2A 177 - 604 l/s 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 Fan RPM rpm 560 585 611 636 662 687 713 738 764 789 814 839 864 889 Motor shaft input power kW 5 5,4 5,7 6,1 6,4 6,8 7,2 7,6 8,1 8,5 9 9,5 10 10,5 90 Sound pressure level dB 85 85 85 85 86 86 86 87 87 87 88 88 89 F.L.I. - Single supply fan kW 7,5 7,5 7,5 7,5 7,5 7,5 7,5 9 9 9 11 11 11 11 A 14,9 14,9 14,9 14,9 14,9 14,9 14,9 19,0 19,0 19,0 21,0 21,0 21,0 21,0 F.L.A. Transmission code (fan) PF 2A 355 PF 2A 315 Transmission code (motor) Air flow PF 2A 280 PF 2A 250 PV 2A 164 704 l/s 8889 8889 8889 8889 8889 8889 8889 8889 8889 8889 8889 8889 8889 Fan RPM rpm 609 632 655 678 701 724 746 769 792 815 838 861 884 8889 906 Motor shaft input power kW 6,7 7,1 7,4 7,8 8,2 8,6 9 9,5 9,9 10,4 10,9 11,3 11,8 12,2 91 Sound pressure level dB 87 87 87 88 88 88 88 88 89 89 89 90 90 F.L.I. - Single supply fan kW 7,5 7,5 7,5 9 9 9 11 11 11 11 15 15 15 15 A 14,9 14,9 14,9 19,0 19,0 19,0 21,0 21,0 21,0 21,0 28,5 28,5 28,5 28,5 F.L.A. Transmission code (fan) PF 2A 355 PF 2A 315 Transmission code (motor) Air flow PF 2A 280 PF 3A 315 PV 2A 164 PF 3A 190 804 l/s 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 Fan RPM rpm 533 556 580 603 626 649 672 695 718 740 762 784 806 10000 827 Motor shaft input power kW 6,4 6,8 7,2 7,7 8,1 8,6 9 9,5 10 10,5 11,1 11,6 11,7 12,2 89 Sound pressure level dB 85 85 85 85 85 86 86 86 87 87 87 88 88 F.L.I. - Single supply fan kW 7,5 7,5 7,5 9 9 9 11 11 11 11 15 15 15 15 A 14,9 14,9 14,9 19,0 19,0 19,0 21,0 21,0 21,0 21,0 28,5 28,5 28,5 28,5 F.L.A. Transmission code (fan) PF 2A 355 Transmission code (motor) Air flow PV 2A 156 PF 2A 315 PV 2A 164 PF 3A 355 PV 2A 177 PF 3A 190 PF 3A 200 904 l/s 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 Fan RPM rpm 578 599 620 642 663 684 704 725 746 766 787 807 827 847 Motor shaft input power kW 8,5 8,9 9,4 9,8 10,3 10,8 11,3 11,8 12,1 12,4 12,9 13,4 14 14,6 Sound pressure level dB 88 88 88 88 88 88 88 88 89 89 89 89 90 90 F.L.I. - Single supply fan kW 11 11 11 11 11 11 15 15 15 15 15 15 15 15 A 21,0 21,0 21,0 21,0 21,0 21,0 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 F.L.A. Transmission code (fan) Transmission code (motor) PF 2A 400 PF 2A 355 PV 2A 177 PF 3A 355 PF 3A 180 BT08A006GB-03 Air flow 11111 PF 3A 315 PF 3A 170 PF 3A 180 The value of absorbed electrical power has already been corrected by a factor that takes into account the losses in transmission and a minimum tolerance on the number of revs of the fan. 27 PACKAGED 362 - 904 AIR FLOW: REDUCED PERFORMANCES OF SUPPLY AIR FANS EXTERNAL STATIC PRESSURE (Pa) Air flow l/s 120 150 180 210 240 270 300 330 360 390 420 450 510 570 4444 4444 4444 4444 4444 4444 4444 4444 4444 4444 4444 4444 4444 4444 362 Fan RPM rpm 638 667 696 724 752 779 805 831 856 881 905 929 975 1020 Motor shaft input power kW 2,99 3,21 3,44 3,66 3,89 4,13 4,36 4,61 4,85 5,09 5,35 5,6 6,11 6,63 Sound pressure level dB 82 83 83 83 84 84 85 85 86 86 86 87 88 88 F.L.I. - Single supply fan kW 4 4 4 4 5,5 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 7,5 A 8,3 8,3 8,3 8,3 11,2 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 14,9 F.L.A. Transmission code (fan) PF 1A 250 Transmission code (motor) Air flow PF 2A 250 PV 1A 139 PF 2A 200 PV 2A 156 402 l/s 4888 4888 4888 4888 4888 4888 4888 4888 4888 4888 4888 4888 4888 4888 Fan RPM rpm 681 708 735 761 786 812 836 861 885 908 931 954 998 1041 Motor shaft input power kW 3,8 4,03 4,27 4,52 4,77 5,02 5,28 5,53 5,79 6,06 6,33 6,6 7,14 7,7 Sound pressure level dB 84 84 85 85 85 86 86 86 87 87 88 88 89 89 F.L.I. - Single supply fan kW 5,5 5,5 5,5 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 7,5 9 9 A 11,2 11,2 11,2 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 14,9 19,0 19,0 F.L.A. Transmission code (fan) PF 2A 280 PF 2A 250 Transmission code (motor) Air flow PF 2A 224 PF 2A 200 PV 2A 156 452 l/s 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 Fan RPM rpm 727 752 777 801 825 849 872 895 918 940 962 984 1026 1067 Motor shaft input power kW 4,77 5,02 5,28 5,55 5,81 6,08 6,36 6,63 6,92 7,19 7,48 7,77 8,35 8,94 Sound pressure level dB 86 86 86 87 87 87 88 88 88 88 89 89 90 90 F.L.I. - Single supply fan kW 7,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 9 9 9 9 A 14,9 14,9 14,9 14,9 14,9 14,9 14,9 14,9 14,9 14,9 19,0 19,0 19,0 19,0 F.L.A. Transmission code (fan) PF 2A 250 Transmission code (motor) Air flow PF 2A 224 PF 2A 250 PV 2A 156 PF 2A 224 PV 2A 177 464 l/s 6389 6389 6389 6389 6389 6389 6389 6389 6389 6389 6389 6389 6389 6389 Fan RPM rpm 598 630 662 693 724 755 785 815 845 873 902 930 984 - Motor shaft input power kW 4,1 4,5 4,9 5,3 5,7 6,1 6,5 7 7,5 8 8,5 9 10 - Sound pressure level dB 82 82 83 84 85 85 86 87 87 88 88 89 90 - F.L.I. - Single supply fan kW 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 9 9 9 11 11 - A 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 19,0 19,0 19,0 21,0 21,0 - F.L.A. Transmission code (fan) PF 2A 300 PF 2A 250 Transmission code (motor) Air flow PF 2A 236 PF 2A 250 PV 2A 156 PV 2A 177 524 l/s 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 Fan RPM rpm 639 667 695 723 751 779 806 833 860 887 914 Motor shaft input power kW 5,4 5,8 6,2 6,6 7 7,4 7,9 8,4 8,9 9,4 9,9 Sound pressure level dB 84 84 85 85 86 87 87 88 88 89 89 F.L.I. - Single supply fan kW 7,5 7,5 7,5 7,5 7,5 9 9 9 11 11 A 14,9 14,9 14,9 14,9 14,9 19,0 19,0 19,0 21,0 21,0 F.L.A. Transmission code (fan) PF 2A 280 Transmission code (motor) Air flow 7222 - 7222 7222 940 991 1041 10,4 11,5 12,2 90 91 92 11 11 15 15 21,0 21,0 28,5 28,5 PF 2A 250 PV 2A 156 - PF 2A 315 PV 2A 177 PV 2A 250 604 l/s 8056 8056 8056 8056 8056 8056 8056 8056 8056 8056 8056 8056 8056 8056 Fan RPM rpm 686 711 736 762 787 812 837 862 886 911 936 960 1008 1055 Motor shaft input power kW 7 7,4 7,8 8,3 8,7 9,2 9,7 10,2 10,7 11,2 11,7 12,3 12,8 14 Sound pressure level dB 86 86 87 87 87 88 88 89 90 90 91 91 92 93 F.L.I. - Single supply fan kW 9 9 9 9 9 11 11 11 11 15 15 15 15 15 A 19,0 19,0 19,0 19,0 19,0 21,0 21,0 21,0 21,0 28,5 28,5 28,5 28,5 28,5 F.L.A. Transmission code (fan) PF 2A 315 PF 2A 280 Transmission code (motor) Air flow 704 PF 3A 355 PV 2A 177 PF3A315 PF3A300 PF3A280 PF 3A 224 PF 3A 200 l/s 8888 8888 8888 8888 8888 8888 8888 8888 8888 8888 8888 8888 8888 8888 Fan RPM rpm 730 753 776 799 822 845 868 890 913 936 958 981 1025 - Motor shaft input power kW 8,9 9,3 9,7 10,2 10,7 11,2 11,7 11,9 12,2 12,7 13,2 13,7 14,9 - Sound pressure level dB 88 88 88 89 89 89 90 90 91 91 92 92 93 - F.L.I. - Single supply fan kW 11 11 11 11 11 15 15 15 15 15 15 15 15 - A 21,0 21,0 21,0 21,0 21,0 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 - PF3A280 - 10000 10000 10000 F.L.A. Transmission code (fan) PF 2A 300 Transmission code (motor) PV 2A 177 Air flow 804 BT08A006GB-03 PF 2A 224 PF3A315 PF 3A 180 l/s 10000 10000 10000 10000 Fan RPM rpm 639 662 684 Motor shaft input power kW 8,5 9 9,5 Sound pressure level dB 86 86 F.L.I. - Single supply fan kW 11 11 A 21,0 21,0 F.L.A. Transmission code (fan) 10000 PF 3A 190 10000 10000 10000 PF 3A 200 10000 707 729 752 774 796 817 838 859 880 921 961 10 10,5 11 11,6 11,9 12,2 12,7 13,3 13,9 15 16,3 86 87 87 87 88 88 89 89 89 90 91 91 11 11 11 15 15 15 15 15 15 15 18,5 18,5 21,0 21,0 21,0 28,5 28,5 28,5 28,5 28,5 28,5 28,5 35,0 35,0 PF 3A 355 PV 2A 187 PF 3A 190 10000 - 10000 PF 2A 355 Transmission code (motor) Air flow PF 3A 300 PF 3A 315 PF 3A 200 PF 3A 300 PF 3A 190 PF3A200 904 l/s 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 11111 Fan RPM rpm 683 704 724 745 766 786 806 826 846 866 885 905 943 - Motor shaft input power kW 11 11,5 11,8 12 12,5 13,1 13,6 14,2 14,7 15,3 15,9 16,5 17,8 - Sound pressure level dB 88 88 88 89 89 89 89 90 90 90 91 91 92 - F.L.I. - Single supply fan kW 15 15 15 15 15 15 15 15 15 18,5 18,5 18,5 18,5 - A 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 35,0 35,0 35,0 35,0 - F.L.A. Transmission code (fan) Transmission code (motor) PF 3A 355 PF 3A 170 PF 3A 180 PF 3A 315 PF 3A 190 PF 3A 180 PF 3A 300 PF 3A 190 - The performance takes into account the pressure drops in the unit (pressure drops in treatment coil, standard filters, etc.). To determine the performance required by the fans, it is necessary to add the desired usable static pressure to the pressure drops of any accessories (e.g. hot water coils, gas module, additional filter section, etc.). The value of absorbed electrical power has already been corrected by a factor that takes into account the losses in transmission and a minimum tolerance on the number of revs of the fan. 28 PACKAGED 362 - 904 INTAKE AIR FLOW: REDUCED AIR FLOW PERFORMANCES OF RETURN AIR FANS 60 90 120 150 180 210 240 270 300 330 360 390 420 450 l/s - 3555 3555 3555 3555 3555 3555 3555 3555 3555 3555 3555 3555 3555 Fan RPM rpm - 451 489 526 562 597 630 663 694 725 755 783 811 839 Motor shaft input power kW - 1,27 1,44 1,61 1,79 1,97 2,16 2,35 2,55 2,75 2,95 3,16 3,36 3,58 Sound pressure level dB - 76 77 78 78 79 79 80 81 81 82 83 83 84 F.L.I. - Single supply fan kW - 2,2 2,2 2,2 2,2 2,2 3 3 3 4 4 4 4 4 A - 4,8 4,8 4,8 4,8 4,8 6,5 6,5 6,5 8,3 8,3 8,3 8,3 8,3 Air flow 362 F.L.A. Transmission code (fan) - Transmission code (motor) - Air flow PF 1A 355 PF 1A 315 PF 1A 300 PF 1A 250 PV 1A 139 PV 1A 156 402 l/s 3911 3911 3911 3911 3911 3911 3911 3911 3911 3911 3911 3911 3911 - Fan RPM rpm 441 512 512 547 580 613 645 676 706 735 764 792 819 - Motor shaft input power kW 1,42 1,77 1,77 1,96 2,15 2,35 2,55 2,75 2,96 3,17 3,39 3,6 3,83 - Sound pressure level dB 78 79 79 79 80 80 81 81 82 82 83 83 84 - F.L.I. - Single supply fan kW 2,2 2,2 2,2 3 3 3 3 3 4 4 4 4 4 - A 4,8 4,8 4,8 6,5 6,5 6,5 6,5 6,5 8,3 8,3 8,3 8,3 8,3 - F.L.A. Transmission code (fan) PF 1A 355 Transmission code (motor) Air flow PF 1A 315 PV 1A 139 l/s 4267 4267 PF 1A 280 PF 1A 250 PV 1A 156 4267 4267 4267 4267 4267 4267 4267 - 4267 4267 4267 4267 4267 452 Fan RPM rpm 471 504 537 569 600 631 661 691 719 747 775 802 828 853 Motor shaft input power kW 1,78 1,97 2,16 2,36 2,56 2,77 2,99 3,2 3,42 3,65 3,88 4,11 4,34 4,58 Sound pressure level dB 80 80 81 81 81 82 82 82 83 83 84 84 85 85 F.L.I. - Single supply fan kW 3 3 3 3 3 3 4 4 4 4 5,5 5,5 5,5 5,5 A 6,5 6,5 6,5 6,5 6,5 6,5 8,3 8,3 8,3 8,3 11,2 11,2 11,2 11,2 F.L.A. Transmission code (fan) PF 1A 400 PF 1A 315 Transmission code (motor) Air flow PF 1A 280 PF 1A 400 PV 1A 156 PV 1A 250 464 l/s - - 5111 5111 5111 5111 5111 5111 5111 5111 5111 5111 5111 5111 Fan RPM rpm - - 492 532 571 609 647 683 719 754 788 821 853 884 Motor shaft input power kW - - 2,1 2,4 2,8 3,1 3,5 3,8 4,2 4,6 5,1 5,5 6 6,4 Sound pressure level dB - - 76 78 79 80 81 82 83 84 85 85 86 87 F.L.I. - Single supply fan kW - - 3 3 3 4 4 4 5,5 5,5 5,5 7,5 7,5 7,5 A - - 6,5 6,5 6,5 8,3 8,3 8,3 11,2 11,2 11,2 14,9 14,9 14,9 - - F.L.A. Transmission code (fan) Transmission code (motor) PF 1A 355 PF 1A 315 PF 2A 300 - - l/s 5778 5778 5778 5778 5778 5778 5778 5778 5778 5778 5778 5778 5778 5778 Fan RPM rpm 446 481 517 552 587 622 656 690 723 756 788 819 850 880 Motor shaft input power kW 2,2 2,5 2,7 3,1 3,4 3,7 4,1 4,5 4,9 5,3 5,8 6,2 6,7 7,1 Sound pressure level dB 77 78 79 79 80 81 82 83 84 85 85 86 87 87 F.L.I. - Single supply fan kW 4 4 4 4 4 4 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 A 8,3 8,3 8,3 8,3 8,3 8,3 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 Air flow 524 F.L.A. Transmission code (fan) PF 1A 355 Transmission code (motor) Air flow PV 1A 156 PF 2A 280 PV 2A 177 PF 1A 300 PF 2A 280 PV 1A 139 PV 2A 156 PV 2A 177 604 l/s 6444 6444 6444 6444 6444 6444 6444 6444 6444 6444 6444 6444 6444 6444 Fan RPM rpm 481 513 544 576 607 639 670 701 732 762 792 822 851 880 Motor shaft input power kW 2,9 3,2 3,5 3,8 4,1 4,5 4,9 5,3 5,7 6,1 6,6 7 7,5 8 Sound pressure level dB 80 80 81 81 82 83 83 84 85 85 86 87 87 88 F.L.I. - Single supply fan kW 4 4 4 4 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 9 9 A 8,3 8,3 8,3 8,3 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 19,0 19,0 F.L.A. Transmission code (fan) PF 1A 315 Transmission code (motor) PV 1A 139 Air flow PF 2A 300 PF 2A 280 PV 2A 156 PV 2A 177 704 l/s 7111 7111 7111 7111 7111 7111 7111 7111 7111 7111 7111 7111 7111 - Fan RPM rpm 517 545 574 603 631 660 689 717 745 773 801 829 856 - Motor shaft input power kW 3,7 4 4,4 4,7 5,1 5,4 5,8 6,2 6,6 7,1 7,5 8 8,5 - Sound pressure level dB 82 82 83 83 84 84 84 85 86 86 87 88 88 - F.L.I. - Single supply fan kW 5,5 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 7,5 9 9 9 - A 11,2 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 14,9 19,0 19,0 19,0 - F.L.A. Transmission code (fan) PF 2A 355 PF 2A 300 Transmission code (motor) Air flow PF 2A 280 PV 2A 164 - PV 2A 177 - 804 l/s 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 Fan RPM rpm 458 488 516 545 573 601 629 656 682 708 734 759 784 808 Motor shaft input power kW 3,6 4 4,4 4,7 5,1 5,6 6 6,4 6,9 7,4 7,9 8,4 8,9 9,4 Sound pressure level dB 80 80 81 81 81 82 83 83 84 84 85 86 86 87 F.L.I. - Single supply fan kW 5,5 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 9 9 9 11 11 A 11,2 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 19,0 19,0 19,0 21,0 21,0 8889 F.L.A. Transmission code (fan) PF 2A 400 Transmission code (motor) PV 2A 164 Air flow PF 2A 355 PF 2A 315 PV 2A 177 904 l/s 8889 8889 8889 8889 8889 8889 8889 8889 8889 8889 8889 8889 8889 Fan RPM rpm 493 519 546 572 597 623 648 673 698 722 746 770 793 816 Motor shaft input power kW 4,8 5,1 5,5 5,9 6,4 6,8 7,2 7,7 8,2 8,7 9,2 9,7 10,2 10,8 88 Sound pressure level dB 82 82 83 83 83 84 84 85 85 86 86 87 87 F.L.I. - Single supply fan kW 5,5 5,5 7,5 7,5 7,5 7,5 7,5 9 9 9 11 11 11 11 A 11,2 11,2 14,9 14,9 14,9 14,9 14,9 19,0 19,0 19,0 21,0 21,0 21,0 21,0 F.L.A. Transmission code (fan) Transmission code (motor) PF 2A 400 BT08A006GB-03 EXTERNAL STATIC PRESSURE (Pa) PF 2A 355 PV 2A 164 PF 2A 315 PF 2A 300 PV 2A 177 The value of absorbed electrical power has already been corrected by a factor that takes into account the losses in transmission and a minimum tolerance on the number of revs of the fan. 29 PACKAGED 362 - 904 AIR FLOW: HIGH PERFORMANCES OF SUPPLY AIR FANS EXTERNAL STATIC PRESSURE (Pa) Air flow l/s 120 150 180 210 240 270 300 330 360 390 420 450 510 570 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 6666 362 Fan RPM rpm 824 844 865 885 906 926 946 965 985 1004 1024 1043 1080 1117 Motor shaft input power kW 8,01 8,31 8,62 8,93 9,24 9,56 9,88 10,21 10,53 10,86 11,2 11,53 11,7 12,36 Sound pressure level dB 90 90 90 91 91 91 91 91 92 92 92 92 93 93 F.L.I. - Single supply fan kW 9 9 9 9 11 11 11 11 11 11 15 15 15 15 A 19,0 19,0 19,0 19,0 21,0 21,0 21,0 21,0 21,0 21,0 28,5 28,5 28,5 28,5 F.L.A. Transmission code (fan) PF 2A 280 PF 2A 250 Transmission code (motor) Air flow PF 2A 236 402 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 7222 Fan RPM rpm 869 889 908 927 946 965 983 1002 1020 1039 1057 1075 1110 1145 Motor shaft input power kW 9,79 10,11 10,44 10,77 11,11 11,45 11,79 11,87 11,96 12,3 12,63 12,97 13,66 14,36 Sound pressure level dB 92 92 92 92 92 92 93 93 93 93 93 93 94 94 F.L.I. - Single supply fan kW 11 11 11 11 15 15 15 15 15 15 15 15 15 15 A 21,0 21,0 21,0 21,0 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 Transmission code (fan) PF 2A 250 Transmission code (motor) PV 2A 177 Air flow PF 2A 355 PF 2A 236 7222 PF 2A 300 PF 2A 250 PF 2A 224 PF 2A 236 452 l/s 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 - - Fan RPM rpm 905 923 942 960 979 997 1015 1033 1050 1068 1086 1103 - - Motor shaft input power kW 11 11,33 11,68 11,76 11,85 12,19 12,53 12,87 13,21 13,56 13,91 14,26 - - Sound pressure level dB 93 93 93 93 93 93 93 94 94 94 94 94 - - F.L.I. - Single supply fan kW 15 15 15 15 15 15 15 15 15 15 15 15 - - A 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 - - - - F.L.A. Transmission code (fan) PF 2A 355 Transmission code (motor) Air flow PF 2A 224 PF 2A 236 464 rpm 770 791 812 833 854 875 896 917 938 Motor shaft input power kW 11 11,4 11,9 12,1 12,3 12,8 13,3 13,8 14,3 Sound pressure level dB 90 90 90 90 91 91 91 91 92 F.L.I. - Single supply fan kW 15 15 15 15 15 15 15 15 A 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 PF 3A 355 Transmission code (motor) 9722 9722 PF 3A 315 9722 9722 PF 3A 300 PF 3A 190 9722 PF 2A 236 Fan RPM Air flow 9722 PF 2A 224 9722 Transmission code (fan) 9722 PF 2A 315 l/s F.L.A. 9722 9722 - - 9722 9722 9722 9722 959 979 1000 1041 1082 14,8 15,4 15,9 17 18,2 92 92 93 93 94 15 18,5 18,5 18,5 18,5 18,5 28,5 35,0 35,0 35,0 35,0 35,0 PF 3A 280 PF 3A 300 PF 3A 180 PF 3A 280 PF 3A 200 524 l/s 10833 10833 10833 10833 10833 10833 10833 10833 10833 10833 10833 10833 10833 10833 Fan RPM rpm 832 851 870 889 907 926 945 964 983 1001 1020 1039 1076 - Motor shaft input power kW 13,8 14,3 14,8 15,3 15,8 16,3 16,8 17,3 17,8 18,4 19 19,5 20,7 - Sound pressure level dB 92 92 92 92 93 93 93 93 94 94 94 94 95 - F.L.I. - Single supply fan kW 15 15 15 18,5 18,5 18,5 18,5 18,5 18,5 22 22 22 22 - A 28,5 28,5 28,5 35,0 35,0 35,0 35,0 35,0 35,0 41,0 41,0 41,0 41,0 - F.L.A. Transmission code (fan) PF 3A 315 Transmission code (motor) Air flow PF 3A 180 604 l/s 11667 Fan RPM rpm Motor shaft input power kW Sound pressure level F.L.I. - Single supply fan F.L.A. PF 3A 190 11667 888 906 923 941 958 17 17,5 18 18,5 19,1 dB 94 94 94 94 94 kW 18,5 18,5 18,5 22 A 35,0 35,0 35,0 41,0 PF3A315 PF 3A 280 PF 3A 200 11667 Transmission code (motor) Air flow PF 3A 300 11667 Transmission code (fan) 704 11667 11667 PF 3A 190 - PF 3A 200 - 11667 11667 11667 11667 11667 11667 11667 11667 976 993 1010 1028 1045 1063 1080 1115 1150 19,6 20,1 20,7 21,3 21,8 22,4 23 24,2 25,5 94 95 95 95 95 95 95 96 96 22 22 22 22 22 22 30 30 30 30 41,0 41,0 41,0 41,0 41,0 41,0 57,0 57,0 57,0 57,0 PF 3A 300 PF 3A 280 PF 3A 190 PF 3A 315 PF 3A 200 PF3A300 PF 3A 236 l/s 12222 12222 12222 12222 12222 12222 12222 12222 12222 12222 12222 12222 12222 12222 Fan RPM rpm 922 939 955 972 988 1005 1022 1038 1055 1072 1088 1105 1138 1172 Motor shaft input power kW 19,3 19,8 20,3 20,9 21,4 21,9 22,5 23,1 23,6 24,2 24,8 25,4 26,7 27,9 Sound pressure level dB 95 95 95 95 95 95 95 96 96 96 96 96 97 97 F.L.I. - Single supply fan kW 22 22 22 22 22 30 30 30 30 30 30 30 30 30 A 41,0 41,0 41,0 41,0 41,0 57,0 57,0 57,0 57,0 57,0 57,0 57,0 57,0 57,0 F.L.A. Transmission code (fan) PF 3A 300 Transmission code (motor) Air flow 804 BT08A006GB-03 PF 2A 224 l/s F.L.A. PF 3A 190 PF 3A 280 PF 3A 200 PF 3A 190 PF 3A 315 PF 3A 200 PF 3A 300 PF 3A 236 l/s 14722 14722 14722 14722 14722 14722 14722 14722 14722 14722 14722 14722 14722 14722 Fan RPM rpm 839 855 871 887 902 918 934 950 965 981 996 1012 1042 1073 Motor shaft input power kW 21,7 22,3 22,9 23,5 24,2 24,8 25,5 26,1 26,8 27,4 28,1 28,8 30,2 31,7 Sound pressure level dB 94 94 94 94 94 94 95 95 95 95 95 95 96 96 F.L.I. - Single supply fan kW 30 30 30 30 30 30 30 30 30 30 30 30 37 37 A 57,0 57,0 57,0 57,0 57,0 57,0 57,0 57,0 57,0 57,0 57,0 57,0 66,0 66,0 F.L.A. Transmission code (fan) PF 5A 355 PF 5A 315 Transmission code (motor) Air flow PF 5A 200 PF 5A 224 904 l/s 15556 15556 15556 15556 15556 15556 15556 15556 15556 15556 15556 15556 15556 15556 Fan RPM rpm 865 881 896 911 926 941 956 971 986 1000 1015 1030 1059 1088 Motor shaft input power kW 24,7 25,3 26 26,6 27,3 27,9 28,6 29,3 29,9 30,6 31,3 32 33,5 35 Sound pressure level dB 95 95 95 95 95 95 96 96 96 96 96 96 97 97 F.L.I. - Single supply fan kW 30 30 30 30 30 30 30 30 37 37 37 37 37 37 A 57,0 57,0 57,0 57,0 57,0 57,0 57,0 57,0 66,0 66,0 66,0 66,0 66,0 66,0 F.L.A. Transmission code (fan) Transmission code (motor) 30 PF 2A 315 PV 2A 177 PF 5A 355 PF 5A 200 PF 5A 224 PF 5A 315 PF 5A 200 PF 5A 224 The performance takes into account the pressure drops in the unit (pressure drops in treatment coil, standard filters, etc.). To determine the performance required by the fans, it is necessary to add the desired usable static pressure to the pressure drops of any accessories (e.g. hot water coils, gas module, additional filter section, etc.). The value of absorbed electrical power has already been corrected by a factor that takes into account the losses in transmission and a minimum tolerance on the number of revs of the fan. PACKAGED 362 - 904 INTAKE AIR FLOW: HIGH AIR FLOW PERFORMANCES OF RETURN AIR FANS Air flow l/s 60 90 120 150 180 210 240 270 300 330 360 390 420 450 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 5333 362 Fan RPM rpm 539 566 593 620 646 672 698 723 748 773 797 821 845 868 Motor shaft input power kW 3,07 3,29 3,51 3,75 3,98 4,22 4,47 4,72 4,98 5,24 5,5 5,77 6,04 6,31 Sound pressure level dB 85 85 85 85 85 85 86 86 86 86 87 87 87 88 F.L.I. - Single supply fan kW 4 4 4 5,5 5,5 5,5 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 A 8,3 8,3 8,3 11,2 11,2 11,2 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 F.L.A. Transmission code (fan) PF 1A 355 Transmission code (motor) Air flow PF 1A 315 PF 1A 450 PF 1A 400 PV 1A 156 PV 1A 250 l/s 5778 5778 5778 5778 5778 5778 5778 5778 5778 5778 5778 5778 5778 Fan RPM rpm 578 603 628 652 677 701 725 749 773 796 819 842 864 5778 887 Motor shaft input power kW 3,84 4,08 4,32 4,57 4,82 5,08 5,34 5,61 5,88 6,15 6,43 6,71 7 7,28 402 Sound pressure level dB 87 87 87 87 87 87 87 87 87 88 88 88 88 89 F.L.I. - Single supply fan kW 5,5 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 A 11,2 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 14,9 14,9 14,9 14,9 14,9 F.L.A. Transmission code (fan) PF 1A 315 Transmission code (motor) Air flow PF 1A 450 PF 1A 400 PV 1A 156 PV 1A 250 452 l/s 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 - - Fan RPM rpm 599 623 647 671 695 718 742 765 788 810 833 855 - - Motor shaft input power kW 4,29 4,54 4,79 5,05 5,31 5,57 5,84 6,12 6,4 6,68 6,96 7,25 - - Sound pressure level dB 88 88 88 88 88 88 88 88 88 88 89 89 - - F.L.I. - Single supply fan kW 5,5 5,5 5,5 5,5 5,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 - - A 11,2 11,2 11,2 11,2 11,2 14,9 14,9 14,9 14,9 14,9 14,9 14,9 - - - - F.L.A. Transmission code (fan) PF 1A 315 Transmission code (motor) PV 1A 156 Air flow PF 1A 450 PF 1A 400 PV 1A 250 - - 464 l/s 7778 7778 7778 7778 7778 7778 7778 7778 7778 7778 7778 7778 7778 7778 Fan RPM rpm 545 571 597 623 649 676 702 728 754 780 806 832 857 883 Motor shaft input power kW 4,6 5 5,3 5,6 6 6,4 6,8 7,2 7,6 8,1 8,5 9 9,5 10 Sound pressure level dB 84 84 85 85 85 85 86 86 86 87 88 88 89 89 F.L.I. - Single supply fan kW 5,5 5,5 5,5 7,5 7,5 7,5 7,5 7,5 9 9 9 11 11 11 A 11,2 11,2 11,2 14,9 14,9 14,9 14,9 14,9 19,0 19,0 19,0 21,0 21,0 21,0 F.L.A. Transmission code (fan) PF 2A 355 Transmission code (motor) PV 2A 156 Air flow PF 2A 315 PF 2A 280 PF 2A 250 PV 2A 164 524 l/s 8667 8667 8667 8667 8667 8667 8667 8667 8667 8667 8667 8667 8667 Fan RPM rpm 594 617 641 664 688 711 735 758 782 805 829 852 875 8667 899 Motor shaft input power kW 6,2 6,6 6,9 7,3 7,5 8,1 8,5 8,9 9,4 9,8 10,3 10,8 11,3 11,8 90 Sound pressure level dB 86 87 87 87 87 87 87 88 88 88 89 89 90 F.L.I. - Single supply fan kW 7,5 7,5 7,5 7,5 9 9 9 11 11 11 11 11 15 15 A 14,9 14,9 14,9 14,9 19,0 19,0 19,0 21,0 21,0 21,0 21,0 21,0 28,5 28,5 F.L.A. Transmission code (fan) PF 2A 315 Transmission code (motor) Air flow PF 2A 300 PV 2A 156 PF 3A 315 PV 2A 177 PF 3A 190 604 l/s 9333 9333 9333 9333 9333 9333 9333 9333 9333 9333 9333 9333 9333 Fan RPM rpm 632 654 676 698 719 741 763 785 807 828 850 872 894 915 Motor shaft input power kW 7,6 8 8,4 8,8 9,2 9,6 10 10,5 10,9 11,4 11,9 12,1 12,3 12,8 Sound pressure level dB 88 88 88 89 89 89 89 89 89 90 90 90 91 91 F.L.I. - Single supply fan kW 9 9 9 9 11 11 11 11 15 15 15 15 15 15 A 19,0 19,0 19,0 19,0 21,0 21,0 21,0 21,0 28,5 28,5 28,5 28,5 28,5 28,5 F.L.A. Transmission code (fan) PF 2A 315 PF 2A 280 Transmission code (motor) Air flow 9333 PF 3A 315 PV 2A 164 PF 3A 180 PF 3A 190 704 l/s 9778 9778 9778 9778 9778 9778 9778 9778 9778 9778 9778 9778 9778 9778 Fan RPM rpm 659 680 700 721 742 763 784 805 825 846 867 888 909 929 Motor shaft input power kW 8,7 9,1 9,5 9,9 10,3 10,8 11,2 11,6 11,9 12,1 12,5 13 13,5 14 Sound pressure level dB 89 89 89 89 90 90 90 90 90 91 91 91 91 92 F.L.I. - Single supply fan kW 11 11 11 11 11 11 15 15 15 15 15 15 15 15 A 21,0 21,0 21,0 21,0 21,0 21,0 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 F.L.A. Transmission code (fan) PF 2A 300 Transmission code (motor) PV 2A 164 Air flow PF 3A 315 PF 3A 170 PF 3A 300 PF 3A 180 PF 3A 190 804 l/s 11778 11778 11778 11778 11778 11778 11778 11778 11778 11778 11778 - - - Fan RPM rpm 603 623 644 664 684 703 723 743 762 782 801 - - - Motor shaft input power kW 9,9 10,3 10,8 11,3 11,8 12 12,3 12,8 13,3 13,9 14,4 - - - Sound pressure level dB 89 89 89 89 89 89 89 89 90 90 90 - - - F.L.I. - Single supply fan kW 11 11 11 15 15 15 15 15 15 15 15 - - - A 21.0 21.0 21.0 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 - - - PF 3A 315 - - - PF 3A 170 - - - F.L.A. Transmission code (fan) PF 2A 355 Transmission code (motor) PV 2A 164 Air flow PF 3A 355 PF 3A 170 PF 3A 180 904 l/s 12444 12444 12444 12444 12444 12444 12444 12444 - - - - - - Fan RPM rpm 632 651 671 690 709 728 746 765 - - - - - - Motor shaft input power kW 11,5 11,8 12 12,5 13 13,5 14 14,5 - - - - - - Sound pressure level dB 90 90 90 90 90 90 90 90 - - - - - - F.L.I. - Single supply fan kW 15 15 15 15 15 15 15 15 - - - - - - A 28,5 28,5 28,5 28,5 28,5 28,5 28,5 28,5 - - - - - - PF 3A 355 - - - - - - PF 3A 180 - - - - - - F.L.A. Transmission code (fan) Transmission code (motor) PF 3A 400 PF 3A 180 PF 3A 190 BT08A006GB-03 EXTERNAL STATIC PRESSURE (Pa) The value of absorbed electrical power has already been corrected by a factor that takes into account the losses in transmission and a minimum tolerance on the number of revs of the fan. 31 PACKAGED 362 - 904 HIGH CUSTOMIZATION OF UNIT Constructive configuration B is equipped with a recirculation air and fresh air mixture chamber, and a single ventilation section for both supply and return. Constructive configuration C is equipped with a recirculation air and fresh air mixture chamber, a ventilation section dedicated to supply and a ventilation section dedicated to return/expulsion. Both constructive configurations B and C can be customized with the selection of a flow rate with three possible values: standard, high, or reduced, based on design needs. EXCLUSIVE OPTIONAL ACCESSORIES OF THE CONFIGURATION B FCB - FREE-COOLING THERMAL VERSION B The configuration with thermal free-cooling for version B allows operation with a variable percentage of refresh air, with opening or closing of the shutters on fresh air and on recirculation air by means of modulating actuators, which intervene when the conditions of fresh air are such that it allows lowering of the internal thermal loads simply by placing primary air in the room. Conditions of adjustment are identified by comparing the outside temperature with that of the served room. In spring or autumn, or in applications where there are high room loads, the configuration with free-cooling makes it possible to substantially reduce the energy consumption of the units and the wear of the compressors. In heat-pump operating mode, the free-heating logic is used. With the same principle as free-cooling, it makes use of the energy contained in the fresh air to increase the thermal load of the served room without the aid of the compressors. The component requires a system for extraction and expulsion of air from the served room, outside the unit (to be provided by the client). FCEB - FREE-COOLING ENTHALPIC VERSION B The configuration with enthalpic free-cooling for version B allows operation with a variable percentage of refresh air, with opening or closing of the shutters on fresh air and on recirculation air by means of modulating actuators, which intervene when the conditions of fresh air are such that it allows lowering of the internal thermal loads simply by placing primary air in the room. Conditions of adjustments are determined by the comparison not only of the temperature but also of the humidity between the exterior and the served room. SERM - MOTORIZED FRESH AIR SHUTTER ON/OFF Opening or closing of the fresh air shutter is controlled by an ON-OFF actuator which, with the machine running, opens the shutter to a preset value while, with the machine shut down, closes the shutter, thus avoiding the "chimney effect" of the ducts with heat loss to the exterior. SERMD - MODULATING MOTORIZED FRESH AIR SHUTTER The configuration with motorized shutter with modulating adjustment for configuration B allows operation with a variable percentage of refresh air with opening or closing of the shutter by means of an actuator driven by a 0-10V signal based on concentrations of CO2 or CO2+VOC detected by the air quality probe. This configuration can be selected only in combination with the air quality probe. BT08A006GB-03 EXCLUSIVE OPTIONAL ACCESSORIES OF THE CONFIGURATION C FCE - ENTHALPIC FREE COOLING The configuration with enthalpic free-cooling is the optional version of version C. This device allows operation with a variable percentage of refresh air, with opening or closing of the shutters on fresh air and on recirculation air by means of modulating actuators, which intervene when the conditions of fresh air are such that it allows lowering of the internal thermal loads simply by placing primary air in the room. Conditions of adjustments are determined by the comparison not only of the temperature but also of the humidity between the exterior and the served room. CANT- APPLICATION WITH FABRIC DUCTS This option allows the fans to start up gradually and means the unit can be adapted to most of the appliances which use fabric ducts to convey the air. Using the soft starter and special technical design features allows the stress on the fabric ducts when the machine starts up to be reduced to a minimum. This option is supplied with the unit in constructive configuration C and a soft starter device. 32 PACKAGED 362 - 904 OPTIONAL ACCESSORIES COMMON TO CONFIGURATIONS B AND C EH - ELECTRIC HEATERS. This option is advisable for cold climates. Available in various powers, it allows heating of the served room. The electrical heating elements are managed by a thermal control device with two power settings. The fins are made of aluminium, with a size suitable to ensure high efficiency and maintain low power density on the surfaces to limit overheating. The low temperature of the heating elements increases their lifespan and limits the effect of air ionization. In heat pump mode, the heating elements may be automatically activated to preheat the inlet air to the main coil, for example during operation with high percentages of fresh air. This extends the operating limits of the machine. The electrical heating elements can be used to boost the yield of the heat pump. The thermal control device is capable of simultaneously activating the preheating and integration functions. Also, the electrical heating elements can be used to reduce the time required for defrosting. COMBINATIONS ELECTRIC HEATERS. 362 Size 402 452 464 524 604 704 804 904 24kW 36kW 48kW 72kW 96kW This operation involves variation of the main electrical data of the machine. hot water coil and electric heaters cannot be mounted at the same time OPERATING LIMITS (Heating) 30 25 To (D.B.) 20 (1) 15 10 5 (2) 0 Delta T -5 -15 -10 -5 0 5 10 15 THE LIMITS ARE INDICATIVE AND HAVE BEEN CALCULATED CONSIDERING: - VALUES GENERAL AND NOT SPECIFICATIONS, - STANDARD AIR FLOW-RATE, - NON-CRITICAL POSITIONING AND CORRECT USE OF THE UNIT, - OPERATION AT FULL LOAD TO = D.B: TEMPERATURE OF INLET AIR MIXTURE (°C) DB = DRY BULB TA = EXTERNAL EXCHANGER INLET AIR TEMPERATURE W.B. (°C) WB = WET BULB (1) THE DASHED AREA REFERS TO THE FIELD OF UNITS OPERATION STANDARD (2) EXTENSION OF THE FIELD OF OPERATION WITH PREHEATING HEATING ELEMENTS. TO OBTAIN THE LOWER LIMIT CURVE, CONSIDER AS THE TEMPERATURE DIFFERENCE (DELTA T) THE VALUE SHOWN IN THE TABLE “EXTENSION OF OPERATING LIMITS WITH PRE-HEATING ELEMENTS”. 20 EXTENSION OF OPERATING LIMITS WITH PRE-HEATING ELEMENTS The pre-heating elements make it possible to increase the temperature of the air mixture entering treatment (temperature To) and make it possible to work with lower temperature limits of the mixture entering the internal heat exchanger, extending the operating range of the machine in winter operation. The table of extension of limits of operation shows the temperature differences (Delta T) to be subtracted from the lower limits of the temperature of the air entering the internal heat exchanger (To) in order to obtain the new limit of operation. 24 kW 36 kW 48 kW 72 kW 96 kW 5555 6111 6666 8055 3.6 3.2 3.0 - 5.3 4.9 4.4 3.7 7.1 6.5 5.9 4.9 7.4 9.8 524 604 704 804 9028 10000 11111 12500 - 3.3 3.0 2.7 1.9 4.4 4.0 3.6 3.2 6.6 5.9 5.3 4.7 8.8 7.9 7.1 6.3 904 13889 - 1.7 2.8 4.3 5.7 Temperature differential (Delta T) of the air that passes through the electrical heating elements [°C] Air flow rate [l/s] 362 402 452 464 Size BT08A006GB-03 Ta (W.B.) 33 PACKAGED 362 - 904 CHW2 - TWO-ROW HOT WATER COIL Option recommended for very cold climates since it allows heating of the served room. The battery is equipped with a thermostat for the anti-freeze function. The anti-freeze function is always active, even when the unit is in standby. If necessary, it forces opening of the valve to the maximum allowable value for allow passage of water in the coil and to prevent the formation of ice. In heat pump mode, the hot water coil may allow both pre-heating of the inlet air to the main coil, as well as integration of the capacity provided by the heat pump. As an alternative, it may intervene in complete substitution of the thermal capacity provided by the compressors. This is possible by setting a turning point, i.e. a temperature limit of the fresh air below which use of the compressors is blocked, and the water coil is used as the sole resource. If the water coil provides pre-heating of the air, the control logic reduces its power to a preset value, which keeps the compressors from working with condensation temperatures that are too high. If instead the water coil is used as the main resource (e.g. because the compressors are not available), the maximum power will be provided. HOT WATER COIL PRESSURE DROP: AIR SIDE 65 464-704 60 804-904 THE AIR SIDE PRESSURE DROPS ARE RELATIVE TO THE MEDIUM AIR TEMPERATURE OF 20°C AND ARE TO BE ADDED TO THE PRESSURE DROPS DUE TO DUCTS, TERMINAL DEVICES AND ANY OTHER COMPONENT THAT CAUSES A DROP IN WORKING DISCHARGE HEAD. Q [L/S] = AIR FLOW RATE 55 50 [Pa] 45 362-452 40 35 30 25 20 15 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 Q [l/s] HOT WATER COIL PRESSURE DROP: WATER SIDE PRESSURE DROPS ON THE WATER SIDE ARE CALCULATED CONSIDERING AN AVERAGE WATER TEMPERATURE OF 65°C Q[L/S]= WATER-FLOW RATE This option reduces the available static pressure (air side). BT08A006GB-03 The component requires connection to the hot water plumbing system (to be provided for by the client). 3WVM - MODULATING 3-WAY VALVE To be used in conjunction with the hot water coil (optional). It is controlled by the on-board microprocessor by means of a 0-10V signal and allows fully automatic adjustment of the hot water coil. The valve with modulating actuator is provided already installed and wired on the machine. PRESSURE DROP MODULATING THREE-WAY VALVE Q[l/s]= WATER-FLOW RATE 34 PACKAGED 362 - 904 PERFORMANCES OF HOT WATER COIL (2 ROWS) Ti/To (°C) Size 80,0 / 65,0 70,0 / 55,0 60,0 / 40,0 80,0 / 65,0 70,0 / 55,0 60,0 / 40,0 80,0 / 65,0 70,0 / 55,0 60,0 / 40,0 Ta (°C) 362 239,4 201,8 151,8 269,8 227,3 170,4 114,4 219,3 182,0 132,4 247,1 205,1 148,6 14 175,0 143,4 101,1 203,4 166,5 117,0 229,3 187,6 131,4 16 168,3 136,8 94,6 195,6 158,8 109,4 220,5 178,9 122,7 18 161,5 130,1 88,1 187,8 151,1 101,8 211,8 170,3 114,2 20 154,9 123,7 81,6 180,1 143,6 94,2 203,1 161,6 105,6 Ta (°C) 4889 Ta (°C) Ta (°C) Ta (°C) Ta (°C) Ta (°C) Ta (°C) Ta (°C) 6111 7222 5 219,8 185,3 139,6 254,9 214,8 161,3 284,1 239,3 179,1 10 201,3 167,2 121,8 233,5 193,8 140,6 260,3 215,9 156,2 14 186,7 152,9 107,7 216,7 177,3 124,3 241,5 197,5 138,1 16 179,6 145,8 100,7 208,3 169,1 116,2 232,2 188,3 129,1 18 172,4 138,8 93,7 200,1 160,9 108,1 223,0 179,3 120,0 20 165,3 131,9 86,8 191,8 152,8 100,1 213,9 170,1 111,0 5333 6667 7500 5 233,0 196,4 147,7 269,8 227,3 170,4 291,0 245,1 183,4 10 213,4 177,2 128,8 247,1 205,1 148,6 266,6 221,2 159,8 14 198,0 162,0 113,9 229,3 187,6 131,4 247,4 202,3 141,3 16 190,4 154,5 106,5 220,5 178,9 122,7 237,9 192,9 132,1 18 182,8 147,1 99,1 211,8 170,3 114,2 228,5 183,6 122,8 20 175,3 139,7 91,7 203,1 161,6 105,6 219,1 174,4 113,6 6389 8056 9722 5 308,1 260,7 198,6 360,2 304,5 230,9 407,5 344,2 260,4 10 283,1 236,2 174,1 331,0 276,0 202,5 374,8 311,9 228,1 14 263,6 216,8 154,7 308,2 253,3 179,9 348,7 286,3 202,5 16 253,9 207,1 145,0 296,9 242,0 168,5 335,8 273,6 189,8 18 244,2 197,5 135,3 285,5 230,8 157,2 323,1 260,9 177,1 20 234,5 188,0 125,6 274,3 219,6 145,9 310,3 248,2 164,2 7222 9028 10833 5 334,8 283,2 215,2 388,3 328,1 248,6 436,8 368,9 278,6 10 307,7 256,6 188,7 357,1 297,3 217,7 401,8 334,3 244,1 14 286,5 235,5 167,6 332,3 272,9 193,4 373,8 306,8 216,5 16 275,9 225,1 157,1 320,0 260,8 181,2 360,0 293,1 202,9 18 265,4 214,6 146,6 307,8 248,7 169,0 346,3 279,5 189,2 20 254,9 204,1 136,0 295,7 236,6 156,8 332,7 265,9 175,5 8056 10000 11667 5 360,2 304,5 230,9 414,9 350,5 265,1 457,8 386,5 291,6 10 331,0 276,0 202,5 381,7 317,6 232,2 420,8 350,2 255,5 14 308,2 253,3 179,9 355,1 291,5 206,1 391,8 321,5 226,6 16 296,9 242,0 168,5 342,0 278,6 193,1 377,4 307,1 212,2 18 285,5 230,8 157,2 329,0 265,6 180,2 363,0 292,9 198,0 20 274,3 219,6 145,9 316,0 252,7 167,0 348,7 278,6 183,5 8889 11111 12222 5 384,4 324,8 246,1 443,8 374,8 283,0 471,3 397,9 299,9 10 353,2 294,4 215,5 408,3 339,7 248,1 433,3 360,6 262,9 14 328,9 270,2 191,5 379,9 311,7 220,0 403,4 330,9 233,1 16 316,8 258,2 179,5 365,9 297,9 206,0 388,6 316,2 218,3 18 304,7 246,2 167,3 352,0 284,0 192,2 373,8 301,5 203,5 20 292,7 234,2 155,2 338,1 270,2 178,2 359,0 286,8 188,7 10000 12500 14722 5 459,3 387,3 290,5 532,4 448,7 335,0 591,7 498,3 371,1 10 421,7 350,4 253,7 489,3 405,8 292,7 543,8 450,8 324,0 14 392,4 321,2 224,7 455,1 372,2 258,8 505,8 413,1 286,5 16 377,8 306,5 210,0 438,1 355,2 242,0 486,9 394,4 267,8 18 363,0 292,3 195,5 420,9 338,3 225,1 468,1 376,1 249,0 20 348,6 277,9 181,0 404,2 321,7 208,4 449,3 357,0 230,2 Qo (l / s) 904 kWt 131,1 Qo (l / s) 804 kWt 6667 156,7 Qo (l / s) 704 kWt 173,8 Qo (l / s) 604 kWt 188,7 Qo (l / s) 524 kWt 5556 206,0 Qo (l / s) 464 kWt 5 Qo (l / s) 452 kWt 10 Qo (l / s) 402 kWt 4444 11111 13889 BT08A006GB-03 kWt Qo (l / s) 15555 5 492,8 415,2 310,8 570,0 480,2 358,1 612,7 515,9 383,9 10 452,8 375,8 271,5 523,9 434,1 312,5 563,1 466,8 335,1 14 420,9 344,5 240,3 487,3 398,1 276,4 523,8 427,6 296,2 16 405,3 328,7 224,7 469,1 380,1 258,5 504,3 408,3 276,9 18 389,7 313,4 209,1 450,9 362,0 240,3 484,8 389,1 257,6 20 374,3 298,1 193,5 432,6 344,0 222,2 465,4 369,9 238,0 Ta = air temperature entering the air handling coil (°C) Ti/To = water temperature inlet/outlet (°C) Qo = air flow (l/s) kWt = Heating capacity (kW) 35 PACKAGED 362 - 904 GH - GAS BURNER This option is advisable for very cold climates. The gas module is available in various powers and allows heating of the served room. Perfect for situations in which climatic conditions make heat pump operation inconvenient or even unsuitable. The gas module must be capable of working as an alternative to the heat pump. Therefore it must be sized with the same thermal power as the design. Thanks to the technology of condensation with premixing and very highefficiency modulation (up to 105% based on the net calorific value), consumption is extremely limited and further reduced during operation at partial loads. Emissions into the atmosphere are minimal, completely free of nitrogen monoxide and with a low content of CO2 which remains constant in the entire working range, as opposed to atmospheric burners. The heating module includes a condensation hot air generator with modulating adjustment, fuelled with methane gas or LPG, and is complete with a steel flue pipe kit and all safety and adjustment devices. The flue pipe kit requires assembly and is to be installed at the worksite. The module is provided standard set up for methane gas. A kit is provided for changeover to LPG. COMBINATIONS GAS MODULE Size 362 402 452 464 524 604 704 804 904 96kW 150kW 200kW 300kW This option reduces the available static pressure (air side). The component requires a supply of gas (gas connection to be provided by the client). Note the presence of the flue pipe and the need to comply with legal requirements in positioning the machine. GAS CONNECTION DIAGRAM (1) MAIN BURNER GAS SOLENOID VALVE (2) PRESSURE STABILIZER (3) GAS SAFETY SOLENOID VALVE (4) GAS FILTER (SMALL SECTION) (5) ANTI-VIBRATION JOINT (6) GAS FILTER (LARGE SECTION) (7) GAS BIBCOCK (8) PILOT BURNER GAS SOLENOID VALVE BT08A006GB-03 INCLUDED GAS CONSUMPTION 96 kW Size description Nominal power efficiency produced condensation gas connection diameter flue pipe diameter supply pressure G20 methane gas consumption supply pressure G31 gas consumption 36 PROVIDED BY THE kW % l/h mm mbar 3 m /h mbar 3 m /h min 31,5 105 150 kW max 93,4 95,3 min 46,3 105,2 max 145 93,5 200 kW min 55,7 105,1 max 197 91,6 300 kW min 92,6 105,2 max 290 93,5 2,6 3,87 4,9 7,74 UNI ISO 7/1-1" M UNI ISO 7/1-1" M UNI ISO 7/1-1" M UNI ISO 7/1-1" M 100 3,17 10,37 1,9 6,21 130 130 20 (Min.17 Max.25) 4,66 16,4 5,61 22,75 37 (Min.25 Max.45) 2,79 9,83 3,36 13,63 130 9,32 32,8 6,72 27,26 PACKAGED 362 - 904 HSE - STEAM HUMIDIFIER WITH IMMERGED ELECTRODES This device is perfect for the winter period when it is necessary to add humidity to the room without cooling the air flow. The modulating automatic adjustment makes it possible to adapt the production of steam and the related operating costs to meet actual needs. Available in different powers, the device is suitable for use with unsoftened water of medium conductivity. It is complete with water filling solenoid valve, disposable cylinder, water drainage solenoid valve, distribution nozzle, electronic control card with functions of verification of water level, verification of conductivity, anti-foam, manual override of water drainage. To ensure the utmost hygiene, the cylinder is automatically drained after a certain period of inactivity. The device includes an automatically activated antifreeze device. A supply probe is used to monitor the humidity level. It is installed and wired on-board the machine. COMBINATIONS ELECTRODE BOILER STEAM HUMIDIFIER Size This operation involves variation of the main electrical data of the machine. This accessory requires the presence of a water circuit and drain on board the machine. Provided by the customer HWS - WATER TO WASTE EVAPORATING WET-DECK HUMIDIFIER This option is recommended when quick, efficient humidification of the served room is required. Humidification of the air mixture occurs by passing the air flow through a honeycomb package that is kept humid at all times by a series of nozzles that inject water in small drops. The reserve of water for treatment is taken directly from the water mains. During operation, the pure water vapour is mixed with the air currents. The remaining part, enriched with mineral salts, is collected in the tub and eliminated. The constant exchange of water ensures cleaning of the evaporation septum and provides maximum limitation of the formation and proliferation of Legionnaire's Disease. With this option, energy consumption for water evaporation is limited. Whenever the packaged humidifier is active, in addition to humidifying, adiabatic cooling of the air takes place, which is constantly compensated for by the thermal control device. Direct connection to the plumbing system eliminates the need for special water treatment and easy control of the humidification process by means of the measuring and adjusting device of the water flow rate provided standard. MEASURING DEVICE ADJUSTER MANUAL SHUT-OFF VALVE This accessory requires the presence of a water circuit and drain on board the machine. Provided by the customer MAXIMUM RATE OF STEAM RELEASED BY THE WET DECK HUMIDIFIER Size 362 402 452 464 524 604 704 804 904 Ta (°C) D.B. Ta (°C) W.B. Kg/h Kg/h Kg/h Kg/h Kg/h Kg/h Kg/h Kg/h Kg/h 30 35 40 15.1 17.6 19.8 115 144 175 127 158 193 138 173 210 167 209 254 187 234 285 207 259 315 230 288 350 259 324 394 288 360 438 BT08A006GB-03 SOLENOID VALVE This option reduces the available static pressure (air side). Ta D.B.= dry bulb temperature of inlet air to the wet deck. Ta W.B.= wet bulb temperature of inlet air to the wet deck. Approximate values of the maximum rate of steam released by the wet deck humidifier to the air to obtain controlled thermal and humidity conditions in supply. The data refer to a unit with standard air flow rate in supply. 37 PACKAGED 362 - 904 AIR FILTERING This is an essential function for proper maintenance of conditions of well-being and hygiene in the served rooms. For this reason it is the subject of precise standards based on the specific applications. The units are standard equipped with filters with an efficiency of G4 on the treatment section. They have an ample surface and low pressure drops. The second filtering stage is available through innovative, high-efficiency filters, electro-static, automatically controlled, class H10. Thanks to the minimum pressure drops and the possibility to wash them, they substantially reduce consumption and hence ventilation costs, while at the same time ensuring excellent performance. As an alternative the more traditional high-efficiency F7 rigid pocket filters are available. F7 - HIGH EFFICIENCY F7 AIR FILTER The multi-dihedral filters with rigid pockets, class F7, are filtering components that are in addition to the standard G4 filters, for more effective filtering. They are widely used in civil air conditioning systems and in industrial applications that require suitable performance concerning fine dusts and particles with dimensions greater than µm. Class F7 filters are made of fibreglass paper, pleated with constant calibrated spacing, mounted on frames with a sturdy structure in extruded moulded polyester; the ample filtering surface reduces air side pressure drops. Class F7 filters must be replaced after reaching their limits of dirtiness with scheduled periodic maintenance. It is possible to provide as an accessory the dirty filters differential switch, which informs the user that the admissible limit of dirtiness has been reached so as not to excessively reduce the air flow rate with respect to the nominal value. This option reduces the available static pressure (air side). FES - AIR FILTER, ELECTRO-STATIC, HIGH-EFFICIENCY, H10 BT08A006GB-03 Class H10 high-efficiency filters are additional filtering components with an active electrostatic system. Solid or liquid particles contained in the air flow are trapped by and electrical field. The air flow through the filter is affected in two main phases: release of an electrical charge to the particles (ionization), and capture of the particles by electrostatic deposit (captivation). On a periodic basis, the filters must be washed to remove the captured particles. The filters are capable of trapping fine dusts, some types of viruses and microorganisms (anti-bacterial action) with very modest pressure drops. The range of use normally includes fine powders that measure less than 1 µm. Typical pollutants are cigarette smoke (0.5÷0.3 µm), oily vapours (1÷0.2 µm), PM10 (particles < 10 µm), PM2.5 (particles < 2.5µm), PM1 (particles < 1µm), etc. Dirtiness of the electric filter is signalled by a sensor that makes it possible to schedule periodic maintenance, which can be easily performed by washing in water with a special non-aggressive detergent for aluminium. The greater initial cost, as compared to a traditional pocket filter, is recovered quickly since the electrostatic filters last for the entire life of the machine, whereas pocket filters require periodic replacement. FLOW OF CONTAMINATED AIR IONIZATION This option reduces the available static pressure (air side). This operation involves variation of the main electrical data of the machine. 38 CAPTIVATION PACKAGED 362 - 904 COMPARISON OF OPERATING COSTS: A CASE STUDY The high-efficiency electrostatic filters allow very rapid return of the initial investment as compared with a traditional filtering system, thanks to the reduction of electrical consumption of the ventilation sections and the greatly reduced maintenance costs, since the filters do not require periodic replacement. A typical case study shows how return on investment occurs in just a few months. In the heavy-duty use of a shopping centre, this occurs by the second year with respect to a traditional system with pocket, F7, highefficiency second stage filtering. This also greatly reduces environmental impact, both due to more rational use of energy, and because no special waste is produced, such as the used traditional pocket filters. 150 (1) COST FOR PURCHASE AND OPERATION OF THE SECOND FILTERING STAGE, TRADITIONAL TYPE, WITH POCKETS, EFFICIENCY F7 (1) 100 Earning as a ofpartire 19th Guadagno month dal 19° mese (2) COST FOR PURCHASE AND OPERATION OF THE SECOND FILTERING STAGE, ELECTROSTATIC TYPE, WITH POCKETS, EFFICIENCY H10 Risparmio Saving [%] unitstandard standard cost for Percentage Costi percentuali riferiti a unità [%] Analysis of costs (electrostatic filters- -filtri pocket filters) Analisi dei costi (filtri elettrostatici a tasche) IN ORDER, THE PERCENTAGE OF COST INCREASES ARE PRESENTED FOR A STANDARD UNIT WITH SINGLE FILTERING STAGE OF G4 EFFICIENCY.OPERATION INCLUDES GREATER COSTS FOR VENTILATION AND MAINTENANCE. PERFORMANCE OF ELECTROSTATIC FILTER: - -25% ON VENTILATION COSTS - -90% ON COSTS OF MAINTENANCE (2) 50 EXAMPLE BASED ON MEDIUM SIZED UNITS USED ON A SHOPPING CENTRE THAT IS OPEN 12 HOURS A DAY, 6 DAYS A WEEK, AND SUBJECT TO ROUTINE MAINTENANCE 3 TIMES A YEAR 0 0 1 2 3 4 5 6 Time [years] Tempo [anni] The values are to be considered approximate. The H10 class electrostatic filters and the F7 pocket filters cannot be included simultaneously on the machine. PSAF - DIFFERENTIAL PRESSURE SWITCH FOR DIRTY AIR FILTERS BT08A006GB-03 It makes it possible to detect and signal (with a suitable alarm) when the dirtiness of the air filter reaches its maximum level. This provides the machine operator with information on when filter maintenance is required. The detection signal is installed in the unit. It is already connected to the electrical panel and pre-calibrated in the factory. Calibration can be modified by a specialized service centre during the commissioning phase. 39 PACKAGED 362 - 904 CPHG - HOT GAS RE-HEATING COIL This option is recommended during the summer when dehumidification of the room is required. The flow of air to enter the room may contain a higher level of humidity than desired. The dehumidification process is used to reduce it. The air flow is first cooled in the treatment coil with separation of condensation. It is then freely postheated to maintain the desired condition of comfort in the room served. The post-heating coil is located behind the treatment coil and is activated by drawing a flow of hot gas down the line from the compressors through the action of a dedicated solenoid valve. The process starts working based on the humidity set-point established by the user. With respect to traditional devices, such as electrical heating elements or hot water coils, the use of the post-heating coil does not consume any energy. It also lowers the condensation temperature, which provides two positive effects: the power absorbed by the compressors is considerably reduced, and at the same time the cooling power is increased with greater EER. TREATMENT COIL HUMID AIR RE-HEATING COIL COLD AIR TREATED AIR HUMIDITY CONDENSATE DISCHARGE COMPRESSORS TO THE CONDENSER BT08A006GB-03 ELECTRONIC EXPANSION VALVE 40 This option reduces the available static pressure (air side). PACKAGED 362 - 904 PERFORMANCE HOT GAS RE-HEATING COIL outdoor air temperature °C 25 27 30 32 35 25 27 30 32 35 25 27 30 32 35 kWt kWt kWt 4444 kWt kWt kWt kWt kWt 5556 kWt kWt kWt kWt kWt 6667 kWt kWt 10 34,0 36,6 40,6 43,3 47,4 38,8 41,8 46,4 49,5 54,2 41,7 45,0 50,0 53,4 58,5 12 31,3 33,9 37,9 40,6 44,7 35,7 38,7 43,3 46,4 51,0 38,4 41,7 46,7 50,0 55,1 14 28,6 31,2 35,2 37,9 41,9 32,6 35,6 40,2 43,3 47,9 35,1 38,4 43,3 46,6 51,7 16 26,0 28,6 32,5 35,2 39,2 29,6 32,6 37,1 40,2 44,8 31,9 35,1 40,0 43,3 48,3 18 23,3 25,9 29,8 32,5 36,5 26,6 29,6 34,0 37,1 41,7 28,6 31,8 36,7 40,0 44,9 20 20,7 23,3 27,2 29,8 33,8 23,6 26,5 31,0 34,0 38,6 25,4 28,6 33,4 36,7 41,6 362 Ta (°C) Qo (l / s) 402 Ta (°C) Qo (l / s) 4889 35,9 38,8 43,0 45,9 50,2 40,9 44,2 49,1 52,4 57,3 45,0 48,6 54,0 57,6 63,1 12 33,1 35,9 40,1 43,0 47,3 37,7 40,9 45,8 49,0 54,0 41,4 45,0 50,3 53,9 59,4 14 30,3 33,1 37,3 40,1 44,4 34,5 37,7 42,5 45,7 50,6 37,9 41,4 46,7 50,3 55,7 16 27,5 30,2 34,4 37,2 41,5 31,3 34,4 39,2 42,4 47,3 34,4 37,8 43,1 46,7 52,1 18 24,7 27,4 31,6 34,4 38,6 28,1 31,2 36,0 39,2 44,1 30,8 34,3 39,6 43,1 48,5 20 21,9 24,6 28,8 31,6 35,8 24,9 28,0 32,8 36,0 40,8 27,4 30,8 36,0 39,5 44,9 Ta (°C) 5333 37,8 40,8 45,3 48,3 52,9 43,0 46,4 51,6 55,1 60,3 46,0 49,6 55,1 58,9 64,5 34,8 37,8 42,3 45,3 49,8 39,6 43,0 48,1 51,5 56,8 42,3 45,9 51,4 55,1 60,7 14 31,9 34,8 39,2 42,2 46,8 36,2 39,6 44,6 48,1 53,3 38,7 42,3 47,7 51,4 56,9 16 28,9 31,8 36,2 39,2 43,7 32,9 36,2 41,2 44,6 49,8 35,1 38,6 44,0 47,7 53,2 18 26,0 28,9 33,2 36,2 40,7 29,5 32,8 37,8 41,2 46,3 31,5 35,0 40,4 44,0 49,5 20 23,0 25,9 30,3 33,2 37,7 26,1 29,4 34,4 37,8 42,9 27,9 31,4 36,8 40,4 45,8 Ta (°C) 6389 50,2 54,1 60,2 64,2 70,4 55,9 60,4 67,2 71,7 78,6 64,4 69,6 77,4 82,7 90,6 46,1 50,0 56,0 60,1 66,2 51,4 55,8 62,5 67,1 73,9 59,1 64,3 72,0 77,3 85,2 14 42,0 46,0 51,9 55,9 62,0 46,9 51,3 57,9 62,4 69,2 53,9 59,0 66,7 71,9 79,8 16 38,0 42,0 47,9 51,9 57,9 42,4 46,8 53,4 57,9 64,6 48,7 53,8 61,5 66,6 74,4 18 34,1 38,0 43,9 47,8 53,8 37,9 42,3 48,9 53,3 60,0 43,6 48,6 56,3 61,4 69,1 20 30,2 34,1 39,9 43,8 49,7 33,6 37,9 44,5 48,8 55,4 38,5 43,6 51,1 56,2 63,8 Ta (°C) 7222 Ta (°C) Ta (°C) Ta (°C) Ta (°C) 10833 54,0 58,3 64,8 69,2 75,9 61,7 66,6 74,1 79,1 86,7 68,6 74,1 82,4 88,0 96,5 12 49,6 53,9 60,4 64,7 71,3 56,6 61,5 69,0 74,0 81,5 62,9 68,4 76,7 82,2 90,7 14 45,3 49,5 55,9 60,3 66,8 51,6 56,5 63,9 68,9 76,4 57,3 62,8 71,0 76,6 85,0 16 41,0 45,2 51,6 55,9 62,4 46,7 51,5 58,9 63,8 71,3 51,8 57,2 65,4 70,9 79,3 18 36,7 40,9 47,2 51,5 57,9 41,8 46,6 53,9 58,8 66,2 46,3 51,7 59,9 65,3 73,6 20 32,5 36,7 43,0 47,2 53,6 36,9 41,7 49,0 53,8 61,2 40,9 46,3 54,4 59,8 68,0 8056 10000 11667 10 57,7 62,3 69,3 73,9 81,0 65,5 70,7 78,7 84,0 92,1 71,5 77,3 86,0 91,8 100,7 12 53,0 57,5 64,5 69,1 76,2 60,1 65,3 73,2 78,5 86,6 65,6 71,3 80,0 85,8 94,6 14 48,3 52,8 59,7 64,4 71,4 54,8 60,0 67,8 73,1 81,1 59,8 65,5 74,1 79,9 88,6 16 43,7 48,2 55,0 59,6 66,6 49,5 54,7 62,5 67,7 75,7 54,0 59,7 68,2 74,0 82,7 18 39,1 43,6 50,4 55,0 61,9 44,3 49,4 57,2 62,4 70,3 48,3 53,9 62,4 68,1 76,8 20 34,6 39,1 45,8 50,3 57,1 39,1 44,3 52,0 57,1 64,9 42,7 48,3 56,7 62,4 70,9 8889 11111 12222 10 61,1 66,0 73,4 78,4 85,9 69,5 75,1 83,6 89,3 97,9 73,4 79,3 88,3 94,3 103,4 12 56,1 61,0 68,3 73,3 80,8 63,8 69,4 77,8 83,5 92,0 67,3 73,2 82,1 88,1 97,2 14 51,2 56,0 63,3 68,2 75,7 58,2 63,7 72,0 77,7 86,2 61,4 67,2 76,0 82,0 91,0 16 46,3 51,1 58,3 63,2 70,6 52,6 58,0 66,4 72,0 80,4 55,4 61,2 70,0 75,9 84,9 18 41,4 46,2 53,4 58,3 65,6 47,0 52,5 60,7 66,3 74,7 49,6 55,3 64,1 70,0 78,8 20 36,6 41,4 48,5 53,3 60,6 41,5 47,0 55,2 60,7 69,0 43,7 49,5 58,2 64,0 72,8 10000 12500 14722 10 78,5 84,6 93,7 99,9 109,3 89,6 96,6 107,1 114,2 124,9 98,5 106,2 117,8 125,6 137,5 12 72,4 78,4 87,5 93,7 103,0 82,7 89,6 100,0 107,1 117,8 90,8 98,5 110,0 117,8 129,6 14 66,4 72,3 81,4 87,5 96,8 75,8 82,6 93,0 100,0 110,6 83,2 90,8 102,3 110,0 121,7 16 60,4 66,3 75,3 81,4 90,6 68,9 75,7 86,0 93,0 103,5 75,6 83,1 94,5 102,2 113,9 18 54,4 60,3 69,2 75,3 84,4 62,0 68,8 79,0 86,0 96,5 68,1 75,6 86,9 94,5 106,1 20 48,4 54,3 63,2 69,2 78,3 55,2 61,9 72,1 79,0 89,5 60,7 68,1 79,3 86,9 98,4 Qo (l / s) 904 9028 10 Qo (l / s) 804 9722 12 Qo (l / s) 704 8056 10 Qo (l / s) 604 7500 12 Qo (l / s) 524 6667 10 Qo (l / s) 464 7222 10 Qo (l / s) 452 6111 11111 13889 BT08A006GB-03 Size 15555 10 83,6 90,1 99,9 106,5 116,5 95,3 102,7 113,9 121,5 132,9 101,7 109,6 121,6 129,7 141,9 12 77,1 83,6 93,3 99,8 109,8 87,8 95,2 106,4 113,9 125,3 93,7 101,6 113,5 121,6 133,7 14 70,7 77,1 86,7 93,2 103,1 80,5 87,8 98,9 106,3 117,7 85,8 93,7 105,5 113,5 125,6 16 64,3 70,6 80,2 86,7 96,5 73,1 80,4 91,4 98,9 110,1 78,0 85,8 97,6 105,5 117,5 18 57,9 64,2 73,7 80,2 90,0 65,9 73,1 84,0 91,4 102,6 70,3 78,0 89,7 97,6 109,5 20 51,5 57,8 67,3 73,7 83,4 58,7 65,9 76,7 84,0 95,2 62,6 70,2 81,8 89,7 101,6 Ta = outlet air temperature from the treatment coil and entering the post-heating coil Qo = air flow rate (l/s) kWt = thermal power provided (kW) The post-heating coil is supplied with hot gas released between the supply of the compressor and the condensation coil. Since the temperature of the hot condensation gas is related to the outside air temperature, the approximate powers of the post-heating coil are expressed based on the outside air temperature. 41 PACKAGED 362 - 904 PAQC - AIR QUALITY SENSOR FOR CO2 P.P.M. CONTROL This option is recommended for areas with highly variable rates of traffic. The probe measure the amount of CO2 in the environment and sends the machine a 0/10V proportional signal. Based on the received signal, the machine manages the input of the correct amount of refresh air, preventing wasted energy and money due to a treatment of fresh air in excess of actual needs. The probe is installed and wired on board the machine and is located in the unit's supply duct. In units in constructive configuration B, the probe must be combined with the modulating fresh air shutter accessory for efficient adjustment of the intake of fresh air. PAQCV - AIR QUALITY SENSOR FOR CO2 AND VOC P.P.M. CONTROL The option is recommended in areas with tobacco smoke, formaldehyde (from solvents, deodorants, glues, paints, detergents), food preparation, etc. The probe measure the amount of CO2 and VOC (volatile organic compounds) in the environment and sends the machine a 0/10V proportional signal. Based on the received signal, the machine manages the input of the correct amount of refresh air, preventing wasted energy and money due to a treatment of fresh air in excess of actual needs. The probe is installed and wired on board the machine and is located in the unit's supply duct. In units in constructive configuration B, the probe must be combined with the modulating fresh air shutter accessory for efficient adjustment of the intake of fresh air. MHP - HIGH AND LOW PRESSURE GAUGES It allows measurement of the pressure of the refrigerant at the supply and return of the compressors, making these parameters easier to check by technicians assigned to operate the machine. The two liquid pressure gauges and corresponding pressure sockets are installed on the machine in an easily accessible location. BT08A006GB-03 CREFB - DEVICE FOR REDUCTION OF FAN CONSUMPTION ECOBREEZE This option is recommended for substantial reduction in the consumption of electrical energy for ventilation and to limit noise emissions in the external section of the machine. The Eco-Breeze logic makes it possible to run the external axial fans with variable rotation speed based on the condensation pressure. When fresh air temperature is low, a minimum air flow rate is required to hold down the condensation pressure. Therefore, at low fresh air temperatures, fan rotation speed is reduced, resulting in reduced electricity consumption and noise emission (summer operation). In operation in heat pump mode with low outside temperature, ventilation is reduced to the external coil so as not to exceed the evaporation pressure limits for correct operation of the unit, with the added benefit of reduced electrical consumption and noise. The Eco-Breeze option uses special fans driven by brushless electric motors with complete electronic control and very high efficiency. 2000 1800 90% 1600 80% 40% 30% 20% 10% % 1200 Input power [W] 50% 3 ph motor Efficiency 60% EcoBreeze 1400 70% 1000 800 600 400 Traditional fans 200 0 1500 EcoBreeze 2000 2500 3000 3500 Air Performance [l/s] 42 4000 4500 5000 PACKAGED 362 - 904 PM - PHASE MONITOR The phase monitor makes it possible to check the correct connection of the phases and their imbalance in units powered with a tri-phase system. If the connection of the phases is not correct, or the limit is exceeded for imbalance between phases, the monitor acts on the control circuit, which orders shutdown of the machine. PFCP - POWER FACTOR CORRECTION CAPACITORS (COSFI > 0.9) The component is necessary to lower the phase difference between current and voltage in the electromagnetic components of the machine, such as asynchronous motors. By re -phasing it is possible to reduce the intensity of the line current by reducing a part of the power of the mains (reactive power). This leads to an economic benefit which the energy provider grants to the final user. The component makes it possible to bring the cosfi power factor to values which on average are greater than 0.9. MOB - SERIAL PORT RS485 WITH MODBUS PROTOCOL It allows serial connection of supervision systems, using ModBus as the communication protocol. It allows access to the complete list of operating variables, controls and alarms. LON - SERIAL PORT RS485 WITH LONWORKS PROTOCOL It allows serial connection of supervision systems, using LonWorks as the communication protocol. It allows access to a list of operating variables, control and alarms compliant with the Echelon standard. RCMRX - REMOTE CONTROL WITH REMOTE MICROPROCESSOR CONTROL Roof-top connection Cable 120 Device which allows complete control of the machine from a remote location. It is easily wallmounted, and has the same appearance and functions as the user interface on board the unit (user-friendly software). To be connected during commissioning of the machine at a maximum distance of 100 m. power supply 150 separately supplied accessories Clivet Management System (CMS) is a Clivet supervision system that allow to schedule and manage all the installed Clivet conditioning units, optimizing their functional working and the others systems in order to reduce the energy consumption. Thanks to the simple use of the software and to the tridimensional graphic interface, it is possible to change complex activities of system operating into simple activities made by the customer. Clivet management system let to visualize the maintenance state of the conditioning units, valuate and manage the alarms. The user makes operation on the supervision workstation or on the PLC (Programmable Logic Controller) interface display. The exchange data between workstation, units, control electronic devices, remote managing electronic devices is made on serial bus networks by communication standard protocol RS485, or on local network LAN (Local Area Network) Ethernet TCP/IP. The control software let to verify the conditioning unit and to make the on-line assistance directly from Clivet factory using the telephone network. BT08A006GB-03 CMS - CLIVET MANAGEMENT SYSTEM (CMS) 43 PACKAGED 362 - 904 CSRN-XHE OPTIONS OPTION DESCRIPTION VERSION B VERSION C Active energy recovery of expelled air - ● Versions RE1 FC Thermal free cooling ○ ● FCE Enthalpy free cooling ○ ○ CB Configuration with mixing and recycling box and ambient air intake ● - CC Configuration with exhaust air fan and mixing box - ● Configurations CREFP Device for fan consumption reduction of the external section with variable speed (phase-cutting) ○ ○ CREFB Device for reduction of fan consumption EcoBreeze ○ ○ CHW2 2 rows hot water coil ○ ○ 3WVM Modulating three-way valve ○ ○ EH Electric heaters ○ ○ GH Gas burner ○ ○ Refrigerant Circuit EVE Electronic expansion valve ● ● MHP High and low pressure gauges ○ ○ CPHG Hot gas re-heating coil ○ ○ FPG4 Pleated air filter class G4 (EN779 norm) ● ● High efficiency F7 air filter ○ ○ High efficiency H10 electrostatic air filter ○ ○ PSAF Differential pressure switch for dirty air filters ○ ○ Ducting Circuit F7 FES HSE Electrode boiler steam humidifier ○ ○ HWS Water to waste evaporating wet-deck humidifier ○ ○ SERM On/off motorized air outlet damper ○ - SERMD Modulating air outlet damper ○* ● SFSTRV Fan breakaway starting current reducing device. * * Application with fabric ducts - ○ CANT Electric Circuit Remote control with remote microprocessor control ○ ○ MOB Serial port RS485 with MODBUS protocol ○ ○ LON Serial port RS485 with LONWORKS protocol ○ ○ Air quality sensor for CO2 p.p.m. control ○ ○ Air quality sensor for CO2 and VOC p.p.m. control ○ ○ Phase monitor ○ ○ Power factor correction capacitors (cosfi > 0.9) ○ ○ RCMRX PAQC PAQCV BT08A006GB-03 PM PFCP ● Standard component. ○ - Optional component. Component not included. ○* Component not necessary with selection of air quality probe; component not necessary with option free-cooling B. * standard for sizes 362-402-452; optional for sizes from 464 to 904 separately supplied accessories 44 PACKAGED 362 - 904 FUNCTIONAL CLEARANCES When placing the unit, it is necessary to comply with the functional spaces indicated in the dimensions. Compliance with fictional spaces is essential to: - ensure proper operation of the unit - allow maintenance technicians easy access to the equipment compartments - protect authorized operators and exposed persons. If several units are placed near one another, the functional spaces between machines must be doubled. DIMENSIONAL DRAWING SIZE 362 – 452 CONSTRUCTION VERSION B DIMENSIONAL DRAWING(1) 4810 3 2 2 546 M 620 * 5 20 17 311 6 4 60 300 1877 2730 * 3970 21 R 113 8 1 905 9 620 * H1 1500** 201 R 2250 297 M 22 W1 W2 1250 2180 2280 60 630 4 7 10 1500** 15 11 16 12 13 18 14 2 1500** 14 W3 AE 6 7 WEIGHT DISTRIBUTION CONSTRUCTIONAL CONFIGURATION: RECIRCULATED/OUTSIDE AIR MIXING BOX (B) Size W1 W2 W3 W4 Shipping weight kg kg kg kg kg 362 402 452 482 504 608 699 2293 486 509 613 705 2313 497 521 627 722 2367 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (8) WATER INLET INTEGRATING COIL Ø 1 1/2" (9) WATER OUTLET INTEGRATING COIL Ø 1 1/2" (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (12) WATER HEATING COIL (OPTIONAL) (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) OUTLET CENTRIFUGAL FAN (16) MOTOR WITH SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (20) RECIRCULATION SHUTTER (OPTIONAL) (21) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (22) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE BT08A006GB-03 H1 W4 The presence of optional accessories may result in a substantial variation of the weights shown in the table. 45 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 362 – 452 CONSTRUCTION VERSION B GAS MODULE 96 kW - 200 kW DIMENSIONAL DRAWING(2) 5962 25 26 24 2 3 28 M 29 890 27 R 20 2 219 2250 872 M R 4 1 619 * 113 17 6 2062 * 2062 * 379 * 60 298 1500 ** 5121 21 7 W3 W2 375 4 H1 1500 10 15 1506 2180 2280 60 H1 22 W1 5 ** 11 16 23 13 18 14 W4 W5 26 6 14 AE 1500 ** 2 W6 7 BT08A006GB-03 WEIGHT DISTRIBUTION 46 CONSTRUCTIONAL CONFIGURATION: RECIRCULATED/OUTSIDE AIR MIXING BOX (B) Size 362 402 452 W1 kg 438 442 450 W2 kg 446 449 458 W3 kg 447 450 459 W4 kg 461 464 473 W5 kg 474 477 487 W6 Shipping weight kg 461 464 473 kg 2726 2746 2800 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) OUTLET CENTRIFUGAL FAN (16) MOTOR WITH SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (20) RECIRCULATION SHUTTER (OPTIONAL) (21) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (22) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS (23) GAS MODULE (24) DISCHARGE WASTE GAS (PROVIDED UN-ASSEMBLED) (25) INTAKING AIR BURNER (26) GAS BURNER COMPARTMENT (27) GAS MODULE SUPPLY (1" GAS) (28) SAFETY THERMOSTAT INSPECTION COMPARTMENT (29) SUPPLY TEMPERATURE PROBE INSPECTION COMPARTMENT R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 362 – 452 CONSTRUCTION VERSION C DIMENSIONAL DRAWING(3) 4810 3 2 2 546 M R 8 6 R 5 19 20 17 311 1 620 * 905 9 60 300 1877 2730 * 3970 4 113 201 ES 2250 297 M 620 * H1 1250 2180 60 630 4 21 22 W1 W2 1500** 2280 7 10 1500** 15 11 16 12 13 18 14 2 AE 6 7 WEIGHT DISTRIBUTION CONSTRUCTIONAL CONFIGURATION: FREE COOLING VERSION WITH EXTRACT/ RECIRCULATED/FRESH AIR INTAKE BOX (C) Size W1 W2 W3 W4 Shipping weight kg kg kg kg kg 362 402 452 552 528 624 696 2399 556 532 629 702 2419 570 546 645 719 2480 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (8) WATER INLET INTEGRATING COIL Ø 1 1/2" (9) WATER OUTLET INTEGRATING COIL Ø 1 1/2" (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (12) WATER HEATING COIL (OPTIONAL) (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) SUPPLY AND RETURN CENTRIFUGAL FANS (16) MOTORS WITH RETURN AND SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (19) DISCHARGE DAMPER (20) RECIRCULATION SHUTTER (21) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (22) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE ES = AIR EXPULSION H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE BT08A006GB-03 14 W3 1500** H1 W4 The presence of optional accessories may result in a substantial variation of the weights shown in the table. 47 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 362 – 452 CONSTRUCTION VERSION C GAS MODULE 96 kW - 200 kW DIMENSIONAL DRAWING(4) 5962 25 26 24 2 3 28 20 M 29 890 27 R ES 2 219 2250 872 M R 19 6 2062 * 113 1 619 * 4 17 2062 * 60 379 * 1500 ** 5121 21 7 4 H1 1500** 10 15 60 375 2280 W3 W2 1506 2180 H1 22 W1 5 298 11 16 23 13 14 18 26 BT08A006GB-03 W4 W5 W6 6 AE 14 1500 ** 2 7 WEIGHT DISTRIBUTION CONSTRUCTIONAL CONFIGURATION: FREE COOLING VERSION WITH EXTRACT/ RECIRCULATED/FRESH AIR INTAKE BOX (C) 362 402 452 W1 kg 467 471 481 W2 kg 471 474 484 W3 kg 459 462 472 W4 kg 476 479 489 W5 kg 487 491 501 W6 Shipping weight kg 472 475 486 kg 2832 2852 2913 Size (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) SUPPLY AND RETURN CENTRIFUGAL FANS (16) MOTORS WITH RETURN AND SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (19) DISCHARGE DAMPER (20) RECIRCULATION SHUTTER (21) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (22) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS (23) GAS MODULE (24) DISCHARGE WASTE GAS (PROVIDED UN-ASSEMBLED) (25) INTAKING AIR BURNER (26) GAS BURNER COMPARTMENT (27) GAS MODULE SUPPLY (1" GAS) (28) SAFETY THERMOSTAT INSPECTION COMPARTMENT (29) SUPPLY TEMPERATURE PROBE INSPECTION COMPARTMENT R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE ES = AIR EXPULSION H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE The presence of optional accessories may result in a substantial variation of the weights shown in the table. 48 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 464 – 704 CONSTRUCTION VERSION B DIMENSIONAL DRAWING(5) 5890 3 2 1680 870 138 185 M R 640 828 1 2 18 2272 5 M 8 660 AE 9 R 2158 2361 * 385 * 1970 2361 * 4 198 6 17 661 693 * 65 1 1 17 65 2185 6 5800 2296 2000* H1 7 8-9 6 7 AE W2 W1 1500** H1 W3 18 14 13 1200** 21 10 11 12 16 2 W6 W5 20 W4 15 WEIGHT DISTRIBUTION CONSTRUCTIONAL CONFIGURATION: RECIRCULATED/OUTSIDE AIR MIXING BOX (B) Size W1 W2 W3 W4 W5 W6 Shipping weight kg kg kg kg kg kg kg 464 524 604 704 498 473 472 484 465 500 2893 511 486 485 498 478 514 2973 556 529 528 541 520 559 3233 568 540 539 553 531 571 3303 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (8) WATER INLET INTEGRATING COIL Ø 2" (9) WATER OUTLET INTEGRATING COIL Ø 2" (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (12) WATER HEATING COIL (OPTIONAL) (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) OUTLET CENTRIFUGAL FAN (16) MOTOR WITH SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (20) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (21) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE BT08A006GB-03 6 The presence of optional accessories may result in a substantial variation of the weights shown in the table. 49 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 464 – 704 CONSTRUCTION VERSION B GAS MODULE 96 kW - 200 kW DIMENSIONAL DRAWING(6) 5890 18 2030 2 24 25 M 5 3 2 2030 1 536 27 26 R R 660 152 2272 M 1015 23 4 64 64 2185 385 * 2361 * 459 2361 * 2000** W1 3976 13 18 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) OUTLET CENTRIFUGAL FAN (16) MOTOR WITH SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (20) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (21) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS (22) GAS MODULE (TO BE CONNECTED TO THE UNIT DURING INSTALLATION) (23) DISCHARGE WASTE GAS (PROVIDED UN-ASSEMBLED) (24) INTAKING AIR BURNER (25) GAS BURNER COMPARTMENT (26) GAS MODULE SUPPLY (1" GAS) (27) CONDENSATE DISCHARGE GAS MODULE R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE 11 20 15 16 2 W4 H1 W5 W7 W8 22 W10 W9 WEIGHT DISTRIBUTION BT08A006GB-03 CONSTRUCTIONAL CONFIGURATION: RECIRCULATED/OUTSIDE AIR MIXING BOX (B) Size kg kg kg kg kg kg kg Size 464 524 604 704 498 473 472 484 465 500 2893 511 486 485 498 478 514 2973 556 529 528 541 520 559 3233 568 540 539 553 531 571 3303 96kW 150-200kW 94 W7 kg 86 W8 kg 83 90 W9 kg 134 146 W10 kg 147 160 Shipping weight kg 450 490 The presence of optional accessories may result in a substantial variation of the weights shown in the table. 50 255 * 46 1200** 6 W1 W2 W3 W4 W5 W6 Shipping weight 1235 * W3 21 W6 255 * 7 AE W2 10 17 64 H1 6 14 1500** 1 2185 693 * 5800 7 1 64 6 148 17 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 464 – 704 CONSTRUCTION VERSION B GAS MODULE 300 kW DIMENSIONAL DRAWING(7) 5890 5169 23 18 5 2272 25 M 2 M 26 25 152 2030 3 1230 24 2 1 R 4 64 2185 7 W1 2361 * 2000** 385 * 2361 * 6 693 * 6 AE 2185 17 255 * 2356 * 255 * 5097 7 W3 18 14 13 21 6 10 11 20 15 2 W6 64 46 H1 5800 W2 1 64 1 64 459 148 17 445 27 536 2030 R W4 16 W5 W8 W7 1500** 1200** H1 22 22 W9 W10 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) OUTLET CENTRIFUGAL FAN (16) MOTOR WITH SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (20) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (21) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS (22) GAS MODULE (TO BE CONNECTED TO THE UNIT DURING INSTALLATION) (23) DISCHARGE WASTE GAS (PROVIDED UN-ASSEMBLED) (24) INTAKING AIR BURNER (25) GAS BURNER COMPARTMENT (26) GAS MODULE SUPPLY (1" GAS) (27) CONDENSATE DISCHARGE GAS MODULE R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE WEIGHT DISTRIBUTION Size W1 W2 W3 W4 W5 W6 Shipping weight kg kg kg kg kg kg kg 464 524 604 704 498 473 472 484 465 500 2893 511 486 485 498 478 514 2973 556 529 528 541 520 559 3233 568 540 539 553 531 571 3303 BT08A006GB-03 CONSTRUCTIONAL CONFIGURATION: FREE COOLING VERSION WITH EXTRACT/RECIRCULATED/ FRESH AIR INTAKE BOX (C) 300kW Size W7 kg 182 W8 kg 173 W9 kg 270 W10 kg 295 Shipping weight kg 920 The presence of optional accessories may result in a substantial variation of the weights shown in the table. 51 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 464 – 704 CONSTRUCTION VERSION C DIMENSIONAL DRAWING(8) 5890 3 2 1680 870 M ES 2 18 M R 640 828 1 138 185 8 660 5 2272 AE 9 R 2158 19 2361 * 385 * 1970 4 198 6 17 661 2361 * 65 1 ES 1 17 65 2185 693 * 6 5800 2296 2000* H1 7 8-9 6 7 W2 W1 1500** AE H1 W3 18 14 13 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (8) WATER INLET INTEGRATING COIL Ø 2" (9) WATER OUTLET INTEGRATING COIL Ø 2" (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (12) WATER HEATING COIL (OPTIONAL) (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) SUPPLY AND RETURN CENTRIFUGAL FANS (16) MOTORS WITH RETURN AND SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (19) DISCHARGE DAMPER (20) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (21) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE ES = AIR EXPULSION H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE 1200** 21 6 10 11 12 16 2 W6 W5 20 W4 BT08A006GB-03 15 WEIGHT DISTRIBUTION CONSTRUCTIONAL CONFIGURATION: FREE COOLING VERSION WITH EXTRACT/ RECIRCULATED/FRESH AIR INTAKE BOX (C) Size W1 W2 W3 W4 W5 W6 Shipping weight kg kg kg kg kg kg kg 464 524 604 704 500 493 492 522 503 502 3013 513 506 505 536 517 516 3093 557 548 548 581 560 559 3353 568 560 559 594 572 571 3423 The presence of optional accessories may result in a substantial variation of the weights shown in the table. 52 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 464 – 704 CONSTRUCTION VERSION C GAS MODULE 96 kW - 200 kW DIMENSIONAL DRAWING(9) 5890 2 2030 3 M 24 25 18 M 5 2 2272 ES 2030 1 536 27 26 R R 660 152 19 1015 23 4 64 64 2185 385 * 2361 * 459 2361 * 2000** W1 17 64 255 * 3976 1235 * 255 * 46 7 AE W3 13 18 1200** 21 6 11 20 15 16 2 W6 1 H1 W2 10 ES 2185 6 14 1500** 1 693 * 5800 7 64 6 148 17 W4 H1 W5 W7 W8 22 W10 W9 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) SUPPLY AND RETURN CENTRIFUGAL FANS (16) MOTORS WITH RETURN AND SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (19) DISCHARGE DAMPER (20) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (21) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS (22) GAS MODULE (TO BE CONNECTED TO THE UNIT DURING INSTALLATION) (23) DISCHARGE WASTE GAS (PROVIDED UN-ASSEMBLED) (24) INTAKING AIR BURNER (25) GAS BURNER COMPARTMENT (26) GAS MODULE SUPPLY (1" GAS) (27) CONDENSATE DISCHARGE GAS MODULE R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE ES = AIR EXPULSION H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE WEIGHT DISTRIBUTION Size W1 W2 W3 W4 W5 W6 Shipping weight kg kg kg kg kg kg kg Size 464 524 604 704 500 493 492 522 503 502 3013 513 506 505 536 517 516 3093 557 548 548 581 560 559 3353 568 560 559 594 572 571 3423 96kW 150-200kW 94 W7 kg 86 W8 kg 83 90 W9 kg 134 146 W10 kg 147 160 Shipping weight kg 450 490 BT08A006GB-03 CONSTRUCTIONAL CONFIGURATION: FREE COOLING VERSION WITH EXTRACT/ RECIRCULATED/FRESH AIR INTAKE BOX (C) The presence of optional accessories may result in a substantial variation of the weights shown in the table. 53 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 464 – 704 CONSTRUCTION VERSION C GAS MODULE 300 kW DIMENSIONAL DRAWING(10) 5890 5169 23 18 5 2272 M 19 25 2 M 26 25 152 2030 3 1230 24 2 R 4 64 64 459 2185 7 2361 * 2000** 385 * W1 2361 * 693 * 5800 64 6 AE 1 64 17 255 * 2356 * 46 5097 18 21 6 10 11 20 15 2 W4 16 W5 W8 W7 1500** 1200** H1 22 22 W10 W9 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) SUPPLY AND RETURN CENTRIFUGAL FANS (16) MOTORS WITH RETURN AND SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (19) DISCHARGE DAMPER (20) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (21) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS (22) GAS MODULE (TO BE CONNECTED TO THE UNIT DURING INSTALLATION) (23) DISCHARGE WASTE GAS (PROVIDED UN-ASSEMBLED) (24) INTAKING AIR BURNER (25) GAS BURNER COMPARTMENT (26) GAS MODULE SUPPLY (1" GAS) (27) CONDENSATE DISCHARGE GAS MODULE R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE ES = AIR EXPULSION H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE WEIGHT DISTRIBUTION BT08A006GB-03 CONSTRUCTIONAL CONFIGURATION: FREE COOLING VERSION WITH EXTRACT/ RECIRCULATED/FRESH AIR INTAKE BOX (C) Size W1 W2 W3 W4 W5 W6 Shipping weight kg kg kg kg kg kg kg 464 524 604 704 500 493 492 522 503 502 3013 513 506 505 536 517 516 3093 557 548 548 581 560 559 3353 568 560 559 594 572 571 3423 300kW Size W7 kg 182 W8 kg 173 W9 kg 270 W10 kg 295 Shipping weight kg 920 The presence of optional accessories may result in a substantial variation of the weights shown in the table. 54 255 * 7 W3 14 13 W6 ES 2185 H1 6 W2 1 148 17 445 27 536 2030 R ES 1 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 804 – 904 CONSTRUCTION VERSION B DIMENSIONAL DRAWING(11) 8024 2 3 1868 1203 9 730 R 740 18 2 M 2272 148 185 1 AE 828 8 5 M R 4 3107 675 * 3093 * 614 2700 3093 * 198 17 64 17 1075 * 1 64 2185 6 7935 1 2296 2000** H1 8-9 6 7 W1 W2 1500** AE 7 H1 W3 1500** 18 14 13 21 6 10 11 12 20 16 2 W6 W4 W5 WEIGHT DISTRIBUTION CONSTRUCTIONAL CONFIGURATION: RECIRCULATED/OUTSIDE AIR MIXING BOX (B) Size W1 W2 W3 W4 W5 W6 Shipping weight kg kg kg kg kg kg kg 804 904 802 766 765 782 753 805 4673 818 782 780 797 769 821 4768 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (8) WATER INLET INTEGRATING COIL Ø 2" (9) WATER OUTLET INTEGRATING COIL Ø 2" (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (12) WATER HEATING COIL (OPTIONAL) (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) OUTLET CENTRIFUGAL FAN (16) MOTOR WITH SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (20) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (21) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE BT08A006GB-03 15 The presence of optional accessories may result in a substantial variation of the weights shown in the table. 55 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 804 – 904 CONSTRUCTION VERSION B GAS MODULE 150 kW - 200 kW DIMENSIONAL DRAWING(12) 8024 2780 AE 5 3 18 M 2 2780 1 1 52 2272 M 536 26 27 R R 660 2 24 25 1015 23 4 64 64 64 2937 676 * 3092 * 3092 * 17 6 459 1 1 17 64 2185 255 * 1235 * 2 55 * 148 17 46 1075 * 3976 7935 2000** H1 6 7 W1 W2 1500** 14 AE 7 H1 W3 1500** 18 13 21 6 10 11 20 16 2 W6 W4 W5 15 W7 W8 22 W10 W9 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) OUTLET CENTRIFUGAL FAN (16) MOTOR WITH SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (20) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (21) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS (22) GAS MODULE (TO BE CONNECTED TO THE UNIT DURING INSTALLATION) (23) DISCHARGE WASTE GAS (PROVIDED UN-ASSEMBLED) (24) INTAKING AIR BURNER (25) GAS BURNER COMPARTMENT (26) GAS MODULE SUPPLY (1" GAS) (27) CONDENSATE DISCHARGE GAS MODULE R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE WEIGHT DISTRIBUTION CONSTRUCTIONAL CONFIGURATION: RECIRCULATED/OUTSIDE AIR MIXING BOX (B) BT08A006GB-03 Size W1 W2 W3 W4 W5 W6 Shipping weight kg kg kg kg kg kg kg 804 904 802 766 765 782 753 805 4673 818 782 780 797 769 821 4768 150-200kW Size W7 kg 111 W8 kg 107 W9 kg 173 W10 kg 189 Shipping weight kg 580 The presence of optional accessories may result in a substantial variation of the weights shown in the table. 56 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 804 – 904 CONSTRUCTION VERSION B GAS MODULE 300 kW DIMENSIONAL DRAWING(13) 8024 5169 23 18 5 2 M M 536 2780 1 2272 26 25 27 R R 17 64 64 4 64 459 6 2937 676 * 3092 * 3092 * 1075 * 6 W1 W2 AE W3 7 17 255 * 2356 * 255 * 46 5097 H1 1500** 18 14 13 1500** 2000** 7 2185 H1 7935 1 64 1 445 3 25 152 AE 148 2780 1230 24 2 21 6 10 11 20 16 2 W6 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) OUTLET CENTRIFUGAL FAN (16) MOTOR WITH SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (20) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (21) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS (22) GAS MODULE (TO BE CONNECTED TO THE UNIT DURING INSTALLATION) (23) DISCHARGE WASTE GAS (PROVIDED UN-ASSEMBLED) (24) INTAKING AIR BURNER (25) GAS BURNER COMPARTMENT (26) GAS MODULE SUPPLY (1" GAS) (27) CONDENSATE DISCHARGE GAS MODULE R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE W4 W5 W7 W8 15 22 22 W9 W10 WEIGHT DISTRIBUTION Size W1 W2 W3 W4 W5 W6 Shipping weight kg kg kg kg kg kg kg 804 904 802 766 765 782 753 805 4673 818 782 780 797 769 821 4768 BT08A006GB-03 CONSTRUCTIONAL CONFIGURATION: RECIRCULATED/OUTSIDE AIR MIXING BOX (B) 300kW Size W7 kg 214 W8 kg 203 W9 kg 317 W10 kg 346 Shipping weight kg 1080 The presence of optional accessories may result in a substantial variation of the weights shown in the table. 57 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 804 – 904 CONSTRUCTION VERSION C DIMENSIONAL DRAWING(14) 8024 2 3 1868 1203 9 R 18 2 M 2272 148 730 ES 740 1 185 19 AE 828 8 5 M R 4 3107 675 * 3093 * 614 2700 3093 * 198 17 1075 * 64 17 ES 1 64 2185 6 7935 1 2296 2000** H1 8-9 6 7 W1 W2 1500** AE 7 H1 W3 1500** 18 14 13 21 6 10 11 12 20 16 2 W6 W4 W5 BT08A006GB-03 15 WEIGHT DISTRIBUTION CONSTRUCTIONAL CONFIGURATION: FREE COOLING VERSION WITH EXTRACT/RECIRCULATED/FRESH AIR INTAKE BOX (C) Size W1 W2 W3 W4 W5 W6 Shipping weight kg kg kg kg kg kg kg 804 904 804 793 791 834 807 806 4835 819 808 807 851 823 822 4930 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (8) WATER INLET INTEGRATING COIL Ø 2" (9) WATER OUTLET INTEGRATING COIL Ø 2" (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (12) WATER HEATING COIL (OPTIONAL) (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) SUPPLY AND RETURN CENTRIFUGAL FANS (16) MOTORS WITH RETURN AND SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (19) DISCHARGE DAMPER (20) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (21) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE ES = AIR EXPULSION H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE The presence of optional accessories may result in a substantial variation of the weights shown in the table. 58 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 804 – 904 CONSTRUCTION VERSION C GAS MODULE 150 kW - 200 kW DIMENSIONAL DRAWING(15) 8024 2780 AE 5 3 18 2780 ES 1 52 19 1 M 2 2272 M 536 26 27 R R 660 2 24 25 1015 23 4 64 64 2937 676 * 3092 * 3092 64 459 * 17 6 1 ES 1 2185 17 64 255 * 1235 * 2 55 * 148 17 46 1075 * 3976 7935 2000** H1 6 7 W1 W2 1500** 14 AE 7 H1 W3 1500** 18 13 21 6 10 11 20 W6 W4 W5 15 W7 W8 22 W10 W9 WEIGHT DISTRIBUTION CONSTRUCTIONAL CONFIGURATION: FREE COOLING VERSION WITH EXTRACT/RECIRCULATED/FRESH AIR INTAKE BOX (C) Size W1 W2 W3 W4 W5 W6 Shipping weight kg kg kg kg kg kg kg 804 904 804 793 791 834 807 806 4835 819 808 807 851 823 822 4930 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) SUPPLY AND RETURN CENTRIFUGAL FANS (16) MOTORS WITH RETURN AND SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (19) DISCHARGE DAMPER (20) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (21) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS (22) GAS MODULE (TO BE CONNECTED TO THE UNIT DURING INSTALLATION) (23) DISCHARGE WASTE GAS (PROVIDED UN-ASSEMBLED) (24) INTAKING AIR BURNER (25) GAS BURNER COMPARTMENT (26) GAS MODULE SUPPLY (1" GAS) (27) CONDENSATE DISCHARGE GAS MODULE R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE ES = AIR EXPULSION H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE BT08A006GB-03 16 2 150-200kW Size W7 kg 111 W8 kg 107 W9 kg 173 W10 kg 189 Shipping weight kg 580 The presence of optional accessories may result in a substantial variation of the weights shown in the table. 59 PACKAGED 362 - 904 DIMENSIONAL DRAWING SIZE 804 – 904 CONSTRUCTION VERSION C GAS MODULE 300 kW DIMENSIONAL DRAWING(16) 8024 5169 23 18 5 M 26 536 2780 ES 2272 19 1 2 M 25 27 R R 17 64 64 4 64 459 6 2937 676 * 3092 * 3092 * 1075 * 6 W1 W2 AE W3 7 64 17 255 * 2356 * 255 * 46 5097 H1 1500** 18 14 13 1500** 2000** 7 ES 1 2185 H1 7935 1 445 3 25 152 AE 148 2780 1230 24 2 21 6 10 11 20 16 2 W6 W4 W5 W7 W8 15 22 22 W9 W10 WEIGHT DISTRIBUTION CONSTRUCTIONAL CONFIGURATION: FREE COOLING VERSION WITH EXTRACT/RECIRCULATED/FRESH AIR INTAKE BOX (C) BT08A006GB-03 Size W1 W2 W3 W4 W5 W6 Shipping weight kg kg kg kg kg kg kg 804 904 804 793 791 834 807 806 4835 819 808 807 851 823 822 4930 (1) REMOVABLE PANEL FOR ACCESS TO THE COMPRESSOR COMPARTMENT (2) ELECTRICAL PANEL (3) MICROPROCESSOR KEYBOARD (4) POWER INPUT (5) HUMIDIFIER INLET CONNECTIONS (6) CONDENSATE DISCHARGE (7) FUNCTIONAL CLEARANCES (10) RE-HEATING COIL (OPTIONAL) (11) TREATMENT COIL (13) ELECTRONIC AIR FILTERS / F7 BAG FILTERS (OPTIONAL) (14) G4 AIR FILTERS (15) SUPPLY AND RETURN CENTRIFUGAL FANS (16) MOTORS WITH RETURN AND SUPPLY TRANSMISSION (17) LIFTING BRACKETS (REMOVABLE, IF REQUIRED, AFTER POSITIONING THE UNIT) (18) FRESH AIR SHUTTER (19) DISCHARGE DAMPER (20) ACCESS TO FANS/MOTORS AND TRANSMISSIONS (21) ACCESS FOR INSPECTION OF COILS, FILTERS, HEATING ELEMENTS (22) GAS MODULE (TO BE CONNECTED TO THE UNIT DURING INSTALLATION) (23) DISCHARGE WASTE GAS (PROVIDED UN-ASSEMBLED) (24) INTAKING AIR BURNER (25) GAS BURNER COMPARTMENT (26) GAS MODULE SUPPLY (1" GAS) (27) CONDENSATE DISCHARGE GAS MODULE R = AIR INTAKE FROM OUTSIDE M=OUTLET AIR AE = FRESH AIR INTAKE ES = AIR EXPULSION H1 = WALL ON TWO SIDES MAX. (*) VIBRATION MOUNTS POSITION (**) SUGGESTED CLEARANCE 300kW Size W7 kg 214 W8 kg 203 W9 kg 317 W10 kg 346 Shipping weight kg 1080 The presence of optional accessories may result in a substantial variation of the weights shown in the table. 60 PACKAGED 362 - 904 STANDARD UNIT SPECIFICATIONS STRUCTURE The basement is assembled with a painted galvanized steel frame. The internal structure is made of “ALUZINK” bent galvanized steel . The alloy that protects the Aluzink allow an excellent corrosion proofing thanks to the galvanic protection typical of the combination aluminium-zinc. PANELLING Panels of the compressor panel in steel sheet metal, painted using polyester powders, colour RAL 9001 and covered on the inside with ashlared soundabsorbent material. Sandwich panels in the air treatment section with dual walls in steel sheet metal with polyurethane insulation (40 kg/m3), thickness of outer sheet metal 6/10 mm galvanized and painted using polyester powders colour RAL 9001, polyurethane thickness with thermal conductivity coefficient 0.022W/mK, thickness of internal sheet metal 5/10 mm hot galvanized. The panel is also provided with a PVC profile for thermal insulation and a EPDM rubber gasket that ensures the hermetic seal. All panelling can easily be removed to allow complete accessibility to internal components. INTERNAL EXCHANGER Direct expansion finned exchanger, made from copper pipes in staggered rows and mechanically expanded to the fin collars. The fins are made from aluminium with a corrugated surface and adequately distanced to ensure the maximum heat exchange efficiency. EXTERNAL EXCHANGER Direct expansion finned exchanger, made from copper pipes in staggered rows and mechanically expanded to the fin collars. The fins are made from aluminium with a corrugated surface and adequately distanced to ensure the maximum heat exchange efficiency. Correct power supply to the expansion valve is ensured by the under-cooling circuit. This circuit also prevents the formation of ice at the base of the heat exchanger during winter operation. FAN INTERNAL SECTION Centrifugal fan with double intake, blades curved forward to achieve maximum performance and silence. Statically and dynamically balanced as per standards ISO 1940 degree 6.3. Fastened to rubber anti-vibration devices. The screw, rotor and frame are made of galvanized sheet metal (semdzimir) the shaft is made of C40 steel. Connection to electric motor with belt and pulleys. EXTERNAL SECTION Helical fans with shaped aluminium blades, directly coupled to the three-phase electric motor, with built-in thermal overload protection, minimum IP 54 construction. Mounted in aerodynamic housings to increase efficiency and minimise noise levels, and fitted with safety grills. REFRIGERANT CIRCUIT The circuit is complete with: - refrigerant charge - sight glass with moisture indicator - high pressure switch - low pressure switch - filter dryer - electronic expansion valve - non-return valve - 4-way reverse cycle valve - liquid receiver - liquid separator - high pressure safety valve - low pressure safety valve FILTRATION Pleated filter for greater filtering surface, made up of galvanized plate frame with galvanized and electric-welded protective mesh, and regenerable filtering media made from polyester fibre sized with synthetic resins. G4 efficiency according to CEN-EN 779 standard (Eurovent class EU4/5 - average efficiency 90.1% ASHRAE 52-76 Atm). Self-extinguishing (resistance to fire class 1 - DIN 53438). ELECTRICAL PANEL The electrical panel is situated inside the units and is accessed through a hinged door that is opened by a special key The Power Section includes: - main door lock isolator switch - compressor circuit breaker - compressor power supply remote control switch - fan motor thermal protections of internal section and external section - circuit breaker to protect auxiliary circuit Microprocessor control section: - treated air temperature control - compressor overload - centralised alarms with remote signalling - self-diagnosis system with immediate display of the error code - demand limit - clean contacts for remote ON-OFF, cumulative alarm, fan status, compressor status, summer/winter mode - control keypad, including: display of the parameter index display of the set values and the error codes menu button to display the parameter index ALARM button to access the alarm management functions status button to display the status list unit operation or ventilation only selection button On/Off and manual reset button for overload device activation UP and DOWN buttons to increase and decrease the values Selected function signal LED Compressor timer / operation signal LED RETURN FAN (Constructional configuration C) Centrifugal fan with double intake, blades curved forward to achieve maximum performance and silence. Statically and dynamically balanced as per standards ISO 1940 degree 6.3. Fastened to rubber anti-vibration devices. The screw, rotor and frame are made of galvanized sheet metal (semdzimir) the shaft is made of C40 steel. Connection to electric motor with belt and pulleys. TEST Unit manufactured according to the ISO 9001 quality standards and subject to functional testing at the end of the production line ACCESSORIES - copper / copper evaporator coils - copper / copper condenser coils - water heating coil - modulating three-way valve - hot gas re-heating coil - Copper / copper hot gas re-heating coil - electrode boiler steam humidifier - water to waste evaporating wet-deck humidifier - Heating module with modulating condensing gas burner - Electric heaters. - Air quality sensor for CO2 p.p.m. control - Air quality sensor for CO2 and VOC p.p.m. control - bag filters section F7 class - High efficiency electrostatic filters additional section - differential pressure switch for dirty air filters - free-cooling with temperature comparison only (standard for version C) - free-cooling with independent comparison of temperature and absolute humidity - Variable fan speed control for operation at low ambient temperature ECOBreeze - fan breakaway starting current reducing device. standard for sizes 362-402-452; optional for sizes from 464 to 904 - Application with fabric ducts (only for C version) - high and low pressure gauges - phase monitor - power factor correction capacitors (cosfi > 0.9) - serial port RS485 with MODBUS protocol - serial port RS485 with LONWORKS protocol - Remote control with remote microprocessor control (separately supplied accessories) BT08A006GB-03 COMPRESSOR Scroll compressor complete with: overload thermal protection, high refrigerant discharge temperature, rubber antivibration mounts, oil charge. A oil heater is automatically switched on at the compressor shut-down to prevent oil dilution by the refrigerant. The compressors are connected in tandem on a single refrigerator circuit. They have bi-phase equalization of the oil and are equipped with cut-off bibcocks TRAY Condensation collection basin in aluminium alloy 1050 H24 with anticondensation insulation, welded and equipped with siphoned drain tube 61 PACKAGED 362 - 904 CLIVET SPA Feltre (BL) ITALY Tel. + 39 0439 3131 Fax + 39 0439 313300 [email protected] CLIVET UK LTD Fareham (Hampshire) U.K. Tel. + 44 (0) 1489 572238 Fax + 44 (0) 1489 573033 [email protected] CLIVET SAS Verrierès le Buisson - FRANCE Tel. + 33 (0)1 69 20 25 75 Fax + 33 (0)1 69 20 60 76 [email protected] CLIVET ESPAÑA S.A. Madrid - SPAIN Tel. + 34 91 6658280 Fax + 34 91 6657806 [email protected] CLIVET GmbH Norderstedt - GERMANY Tel. +49 (0) 40 32 59 57-0 Fax +49 (0) 40 32 59 57-194 [email protected] CLIVET NEDERLAND B.V. Amersfoort - Netherlands Tel. + 31 (0) 33 7503420 Fax + 31 (0) 33 7503424 [email protected] CLIVET RUSSIA Moscow - RUSSIA Tel. +74956462009 Fax +74956462009 [email protected] CLIVET MIDEAST FZC Dubai - UAE Tel. +97 14 3518501 Fax +97 14 3518502 [email protected] CLIVET TF AIR SYSTEMS (P) LTD. Malur - INDIA Tel. +91 8151 232683/5 Fax +91-8151-232684 [email protected] The data contained in this bulletin is not binding and may be changed by the manufacturer without prior notice. All reproduction, even partial, is prohibited. © Copyright - CLIVET S.p.A. - Feltre (BL) - Italy
Similar documents
zephir
ambient. In this way it eliminates the external fresh air load and provides additional capacity to maintain comfort conditions. For users this means a reduction up to 50% in the consumption of prim...
More information