reotemp

Transcription

reotemp
REOTEMP INSTRUMENT CORPORATION
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Table of Contents
Bimetal Thermometers
General Bimetal Specifications
3”, 4” & 5” Back Connection
3”, 4” & 5” All-Angle Connection
3”, 4” & 5” Bottom Connection
Heavy-Duty Navy Thermometer
Dual Mode Thermometer (DMT)
OEM Thermometers
Laboratory Thermometers
Compost Thermometers
Sanitary Bimetal Thermometer
Bimetal Thermometer Accessories
and Ranges
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8-9
Page 10
Page 11
Page 11
Page 12
Page 13
Thermowells
Threaded Type (1/4” elements)
(3/8” elements)
Sanitary Type
Flanged Type
Page 14
Page 24
Page 14
Page 15
Filled System Thermometers
2
Industrial Glass Thermometer
Vapor Actuated
Remote Thermometers
Page 16
Page 17-19
Gas Actuated Remote Thermometers
Bourdon Tube Type
Direct-Drive Type
Page 21-24
Page 25-27
Digital Thermometers
Page 28
RTD’s & Thermocouples
Page 29-32
Sanitary RTD’s
Page 33-34
Surface Thermometers
Page 35
Pocket Thermometers
Page 35
Warranty
Back Page
Established in 1965 and located
in San Diego, California,
R E G I S T E R E D
REOTEMP Instrument Corporation is recognized as a leading
manufacturer of pressure and temperature
instrumentation. REOTEMP provides bimetal
thermometers, pressure gauges, diaphragm
seals and related accessories to a variety of
process markets worldwide. Recognized for
exceptional customer service, on-time deliveries
and innovative engineering services,
REOTEMP is an ISO 9002 certified manufacturer. We are dedicated to continuous improvement, on-time deliveries, high quality products,
and exceptional customer satisfaction.
Markets Served
Oil, Gas & Petrochemical
Pharmaceutical
Food & Beverage
Paper & Pulp
Mining
Utilities
Marine
Waste Water
Compost
Military
Dairy
Power Generation
Refrigeration
And More!
Bimetal Thermometers
Specifications
R E G I S T E R E D
Specifications – Bimetal Dial Thermometers
Dial Sizes: 1 1/8”, 1 3/4” 2 3/8”, 3” 4” 5”
Stem Length: Between 2” and 80”
Stem Diameters: 1/4” (standard),
also available 5/16”, 3/8”.
Heads, bezels, mounting bushing, stems:
All Models 300 series SS
Operating Conditions: The temperature of the
head should not be allowed to exceed 200° F (150°
F if silicone filled). Stems should not be exposed to
continuous temperatures exceeding 50% overrange, or 800° F.
Hermetic seal: All 3”, 4”, and 5” models (except
DM4) are hermetically sealed per ASME B40.3.
Pointed Stems: Optional on all models. Excellent
for probing asphalt, compost, soil, frozen foods or
other semi-solid materials.
Dials: Anodized aluminum. Black marks and numbers with satin matte finish background.
Crystals: Optically clear strong glass.
Optional: Unbreakable clear plastic: all models (Not
recommended for ranges over 500° F).
Optional: “Shatterproof” tempered glass (3”, 4”, and
5” models).
Accuracy: All Models are guaranteed accurate to
within plus or minus 1% of the full scale (Grade A
per ASME B40.3). Temperature readings are
stabilized within 40 seconds.
Immersion: For correct temperature measurement,
the stem of all Models in all ranges must be immersed 2 inches in liquid, and 4 inches in gas except
for 0 to 100° F, 25 to 125° F, and 0 to 50° C which
require 3 1/2 inches in liquid and 5 inches in gas.
Mounting Connections: 1/2” NPT (std. on 3”, 4”,
5” models), 1/8” NPT, 1/4” NPT, 3/8” NPT, 3/4” NPT,
3/8”-24” NF, Plain or Reset Bushing, 1/2” NPT
Union, 1/2” BSPT, BSPP Adapters.
Thermowells
Thermowells should be used whenever the stem or bulb would be exposed to pressure, corrosion, or
shear forces. Thermowells also make it possible to remove the thermometer without losing pressure or
contents. (See pages 14-15 for more details)
O.E.M. Applications
If you are an Original Equipment Manufacturer and plan to incorporate the REOTEMP Thermometer in your
finished product for resale, special ranges or special dials can be made to suit your particular requirements.
Such specials can bear your own company name and/or trademark on the dial. The quality, appearance,
and performance of a REOTEMP Thermometer will complement and enhance your equipment.
3
Bimetal Thermometers
Back Connected
(Angle Form)
Industrial 3”, 4”, 5” Dial
REOTEMP Angle Form thermometers are ideal for
local, eye-level temperature readings in most
process applications.
Standard Features
•
•
•
•
•
All Stainless Steel Construction
Hermetically Sealed (ASME B40.3)
Accurate to 1% of Full Scale
Standard External Reset
Silicone Fillable for Vibration
How to Order
AA
Models
060
Stem
Length
Standard Models
AA = Model A
025 = 2.5"
1
Connection
Standard Threaded*
1 = 1/2" NPT (std.)
(3" dial, reset)
040 = 4"
4 = 1/4" NPT
060 = 6"
5 = 3/4" NPT adapter
090 = 9"
X = Plain Hex Bushing
BB = Model B
(5" dial, reset)
CC = Model C
(4" dial, reset)
(no threads)
120 = 12"
Non-Reset Models
RR = Model R
B = 1/2" BSPT
150 = 15"
Sanitary*
(3" dial, no reset)
180 = 18"
C = 1-1/2" Tri-Clamp
240 = 24"
L = 2" Tri-Clamp
300 = 30"
M = 3/4" Tri-Clamp
360 = 36"
For more information on
Sanitary Thermometers
see page 12
SS = Model S
(5" dial, no reset)
CN = Model CN
(4" dial, no reset)
-Intermediate
lengths available
up to 80”
-Specify length in
inches + tenths
*-Other sizes available
F43
Temperature Ranges
See pg.13 for a full list.
Fahrenheit Ranges
-40 TO 160°F
25 TO 125°F
0 TO 200°F
0 TO 250°F
50 TO 300°F
50 TO 500°F
150 TO 750°F
200 TO 1000°F
Celsius Ranges
-40 TO 70°C
C23
0 TO 50°C
C55*
0 TO 100°C
C43
-20 TO 120°C
C47
0 TO 150°C
C59
0 TO 250°C
C67
0 TO 400°C
C81
100 TO 500°C
C85
Dual F/C Ranges
D23
-40 TO 160°F & -40 TO 70°C
D55*
25 TO 125°F &
0 TO 50°C
0 TO 100°C
0 TO 200°F &
D43
0 TO 250°F & -20 TO 120°C
D47
10 TO 150°C
50 TO 300°F &
D63
0 TO 250°C
50 TO 500°F &
D67
0 TO 400°C
150 TO 750°F &
D81
200 TO 1000°F & 100 TO 500°C
D85
F23
F55*
F43
F47
F63
F67
F81
F85
SF
Options
PS = Pointed Stem
SF = Silicone Fill
(max temp 550°F)
SS = 316 SS Stem
F3 = 3/8" dia. Stem
PC = Acrylic Window
PY = Polycarbonate
Window
TG = Tempered Glass
Window
MM = Max/Min Pointer
For Thermowells
see pg. 14
*-Not available in 2.5" stem.
REOTEMP INSTRUMENT CORPORATION
Telephone: (800) 648-7737 FAX (858) 784-0720 · [email protected] · www.reotemp.com
4
Bimetal Thermometers
Adjustable Angle
Industrial 3”, 4”, 5” Dial
R E G I S T E R E D
REOTEMP All-Angle thermometer allows for easy temperature
monitoring from any position.
Standard Features
•
•
•
•
•
•
•
Complete 180° Adjustability
All Stainless Steel Construction
Hermetically Sealed (ASME B40.3)
Accurate to 1% of Full Scale
Standard External Reset
Silicone Fillable for Vibration
360° Case Rotation
How to Order
LL
Models
Standard Models
LL = Model L
(3" dial, reset)
060
Stem
Length
1
Connection
025 = 2.5"
Standard Threaded
1 = 1/2" NPT (std.)
040 = 4"
5 = 3/4" NPT adapter
060 = 6"
U = 1/2" NPT Union
090 = 9"
Sanitary*
C = 1-1/2" Tri-Clamp
MM = Model M
(4" dial, reset)
JJ = Model J
(5" dial, reset)
120 = 12"
L = 2" Tri-Clamp
150 = 15"
M = 3/4" Tri-Clamp
180 = 18"
240 = 24"
300 = 30"
360 = 36"
For more information on
Sanitary Thermometers see
page 12
-Intermediate
lengths available
up to 80”
-Specify length in
inches + tenths
*-Other sizes available
F43
Temperature Ranges
See pg.13 for a full list.
Fahrenheit Ranges
-40 TO 160°F
F23
25 TO 125°F
F55*
0 TO 200°F
F43
0 TO 250°F
F47
50 TO 300°F
F63
50 TO 500°F
F67
150 TO 750°F
F81
200 TO 1000°F
F85
Celsius Ranges
-40 TO 70°C
C23
0 TO 50°C
C55*
0 TO 100°C
C43
-20 TO 120°C
C47
0 TO 150°C
C59
0 TO 250°C
C67
0 TO 400°C
C81
100 TO 500°C
C85
Dual F/C Ranges
-40
TO 160°F &
-40 TO 70°C
D23
0 TO 50°C
D55* 25 TO 125°F &
0 TO 100°C
0 TO 200°F &
D43
0
TO
250°F
-20
TO 120°C
&
D47
10 TO 150°C
50 TO 300°F &
D63
0 TO 250°C
50 TO 500°F &
D67
0 TO 400°C
D81 150 TO 750°F &
D85 200 TO 1000°F& 100 TO 500°C
SF
Options
PS = Pointed Stem
SF = Silicone Fill
(max temp 550°F)
SS = 316 SS Stem
F3 = 3/8" dia. Stem
PC = Acrylic Window
PY = Polycarbonate
Window
TG = Tempered Glass
Window
MM = Max/Min Pointer
For Thermowells
see pg. 14
*-Not available in 2.5" stem.
5
Bimetal Thermometers
Bottom Connected
(Straight Form)
Industrial 3”, 4”, 5” Dial
.75
Reset
3" dia (Model XR)
4" dia (Model Y)
5" dia (Model VR)
REOTEMP
Straight Form
R E G I S T E R E D
thermometers
are ideal for
side and elevated installations
on tops or sides of tanks or
pipes.
Standard Features
• Bottom, Top, Right or Left
Side Mounting
• All Stainless Steel
Construction
• Hermetically Sealed
(ASME B40.3)
• Accurate to 1% of Full Scale
• Standard External Reset
• Silicone Fillable for Vibration
.62
Stem
Length
1/4" dia
(Standard)
How to Order
XR
060
Models
Stem
Length
Standard Models
XR = Model XR
1
Connection
025 = 2.5"
Standard Threaded*
1 = 1/2" NPT (std.)
040 = 4"
4 = 1/4" NPT
060 = 6"
5 = 3/4" NPT adapter
090 = 9"
Sanitary*
C = 1-1/2" Tri-Clamp
(3" dial, reset)
YY = Model Y
(4" dial, reset)
VR = Model VR
(5" dial, reset)
120 = 12"
Non-Reset Models
XX = Model X
L = 2" Tri-Clamp
150 = 15"
(3" dial, no reset)
M = 3/4" Tri-Clamp
180 = 18"
YN = Model YN
(4" dial, no reset)
VV = Model V
240 = 24"
300 = 30"
For more information on
Sanitary Thermometers
see page 12
(5" dial, no reset)
360 = 36"
-Intermediate
lengths available
up to 80”
-Specify length in
inches + tenths
*-Other sizes available
F43
Temperature Ranges
See pg.13 for a full list.
Fahrenheit Ranges
-40 TO 160°F
25 TO 125°F
0 TO 200°F
0 TO 250°F
50 TO 300°F
50 TO 500°F
150 TO 750°F
200 TO 1000°F
Celsius Ranges
-40 TO 70°C
C23
0 TO 50°C
C55*
0 TO 100°C
C43
-20 TO 120°C
C47
0 TO 150°C
C59
0 TO 250°C
C67
0 TO 400°C
C81
100 TO 500°C
C85
Dual F/C Ranges
D23 -40 TO 160°F & -40 TO 70°C
0 TO 50°C
&
D55* 25 TO 125°F
0 TO 100°C
0 TO 200°F
&
D43
0 TO 250°F
& -20 TO 120°C
D47
50 TO 300°F
& 10 TO 150°C
D63
0 TO 250°C
50 TO 500°F
&
D67
0 TO 400°C
D81 150 TO 750°F &
D85 200 TO 1000°F & 100 TO 500°C
F23
F55*
F43
F47
F63
F67
F81
F85
*-Not available in 2.5" stem.
SF
Options
PS = Pointed Stem
SF = Silicone Fill
(max temp 550°F)
SS = 316 SS Stem
F3 = 3/8" dia. Stem
PC = Acrylic Window
PY = Polycarbonate
Window
TG = Tempered Glass
Window
MM = Max/Min Pointer
99 = 9 O'Clock Stem
(left side)
33 = 3 O'Clock Stem
(right side)
12 = 12 O'Clock Stem
(top mount)
REOTEMP INSTRUMENT CORPORATION
Telephone: (800) 648-7737 FAX (858) 784-0720 · [email protected] · www.reotemp.com
6
Bimetal Thermometers
Heavy-Duty
“Navy” Type
Heavy-Duty Navy Type
Standard Features
•
•
•
•
•
•
•
•
Back (Angle) Form
3” Dial – Bimetal Actuation
Heavy Duty – Vibration and Shock Resistant
Stainless Steel – Sealed Construction
Plastic Crystal
External Reset is Standard
1% Accuracy
Fits in 5” Scale “Submarine” Thermometer Well
3/4” – 28 UN2A Union Connection – (to be used in thermowell)
How to Order
1. Model
2. Range
M odels
Straight Form
Ran ges
B ack Angle Form
AN2= 2”
AN4= 4”
AN6= 6”
Straight Form
XN2= 2”
XN4= 4”
XN6= 6”
F23
F25
F43
F53
F63
F65
F69
F73
N ote: m inim um
im m ersion length is 2”
C13
C53
C59
C65
C69
Fahrenheit R ang es
-40 TO 120° F in 2° divs.*
-40 TO 180° F in 2° divs.
0 T O 200° F in 2° divs.
20 T O 240° F in 2° divs.
50 T O 300° F in 2° divs.
50 T O 400° F in 5° divs.
50 T O 550° F in 5° divs.
50 T O 750° F in 10° divs.
C elsius R anges
-50 TO 50° C in 1° divs.*
-10 TO 110° C in 1° divs.
0 T O 150° C in 2° divs.
0 T O 200° C in 2° divs.
0 T O 300° C in 5° divs.
*-4" M inim um stem length
(on straight, left, or right side form s only)
Thermometer
Wells
Well
Class
Class A
(3/4" NPT)
Class W
(Socket Weld)
Thermometer Well Length
Model No.
Stem Length
(overall)
Brass 304 SS 316 SS
2"
4"
6"
2"
4"
6"
3 1/4"
5 1/4"
7 1/4"
3 5/16"
5 5/16"
7 5/16"
STN2B
STN4B
STN6B
STN2S STN2SS
STN4S STN4SS
STN6S STN6SS
SWN2SS
SWN4SS
SWN6SS
A & W Wells
1"
2
3"
4
STEM
LENGTH
1 "DIA.
2
1 5/16"
STEM
LENGTH
1.05"
DIA.
Bimetal Thermometers
Silicone-Filled Thermometers
REOTEMP Silicone-filled thermometers are offered for severe industrial applications,
where vibration is a problem. Silicone dampening prolongs instrument life by preventing wear and fatigue in the instrument’s internal parts. The silicone also improves
readability by reducing pointer flutter, and promotes faster temperature response.
Any REOTEMP 3”, 4” or 5” dial bimetal thermometer (except Model DM4)
can be silicone filled, in any stem length, and any temperature range up to
550° F. (Silicone filling with ranges over 550° F not recommended.) All
silicone-filled thermometers come with a durable polycarbonate crystal.
How to Order
Specify option “SF” at the end of any 3”, 4” or 5” dial bimetal thermometer.
(e.g., Model AA-040-1-F47-SF). See pg. 4-6
7
Bimetal Thermometers
Dual-Mode Thermometer
R E G I S T E R E D
REOTEMP DUAL MODE THERMOMETER (model DMT) is a convenient, multipurpose indicator for
local and remote temperature monitoring. This rugged dual-sensor system puts TWO SENSORS in
ONE THERMOWELL, and allows easy tie-in to process control. Both sensors are NIST traceable,
and easily calibrated. Special sensor encapsulation and optional liquid filling make the DMT the most
rugged, durable instrument of its kind.
Bimetal Thermometer
• Local easy-to-read Temperature Indication
• Self-actuating, Dampened Bimetal Helix
• Choice of three Dial Sizes, with Back, Bottom, or Adjustable Angle Connection
• Hermetically Sealed per ASME B40.3
• Thermometer is Easily Calibrated, and Field Replaceable
• NIST Traceable Calibration
Thermocouple or RTD
• Remote and Local Indication
• Data Acquisition for Process Control
• Choice of Connection Styles (see drawing below)
• 4-20mA Transmitter Output Available
Model DMT with
Screw Cover Terminal
Head, and AdjustableAngle Head
DMT Advantages:
• Allows local and remote reading (Up to 1000°F) from one thermowell.
• Bimetal dependability with RTD (or thermocouple) accuracy.
• Redundant sensors for simple, effective calibration or spot checking without
removing instrument from thermowell!
• Easily installed in any standard thermowell.
• Interchangeable with existing thermometer, RTD, Thermocouple.
with optional T/C Transmitter (HT)
or with optiona RTD Transmitter (HR)
REOTEMP INSTRUMENT CORPORATION
8
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Bimetal Thermometers
Dual-Mode Thermometer
How to Order
Model
Style/Stem Stem Length
Temp Range Sensor
(Table 1)
(Table 3)
(Table 2)
(Table 4)
Output
Connection
Thermowell
(Table 6)
(Table 5)
DM
TA
04
F24
TK
MC
046
Table 1 - Style & Stem Dia.
Code
Description
3/8" Stem 1/4" Stem
TA
TC
TB
TL
TM
TJ
4A
4C
4B
4L
4M
4J
Table 6 - Thermowell (.385” & .260” bore)
Process
Stem "U" 3/8 Stem
1/4" Stem
Connection Length Dim 304 SS 316 SS 304 SS 316 SS
3"
4"
5"
3"
4"
5"
Back Connected
Back Connected
Back Connected
Adjustable-Angle
Adjustable-Angle
Adjustable-Angle
1/2" NPT
3/4" NPT
Table 2 - Stem Length
Code Length Code Length
02*
04
06
09
12
2.5"
4"
6"
9"
12"
15
18
24
30
36
Table 3-Temperature Range
Code
* min. stem length 4”
Degrees F & C
D03 -100 TO 100°F & -70 TO 70°C
D23 140 TO 160°F & -40 TO 70°C
D55
25 TO 125°F & 0 TO 50°C
D43
0 TO 200°F & 0 TO 100°C
D47
0 TO 250°F & -20 TO 120°C
D53
20 TO 240°F & -10 TO 115°C
D63
50 TO 300°F & 10 TO 150°C
D65
50 TO 400°F & 10 TO 200°C
D69
50 TO 550°F & 10 TO 290°C
D79 100 TO 800°F & 40 TO 400°C
D85** 200 TO 1000°F&100 TO 500°C
**continuous use over 800F not recommended.
DMT Specifications
Case and Bezel:
Case Style:
Dial Size:
Process
Connection:
External Reset:
Crystal:
071
072
073
074
046
047
048
049
053
054
055
056
171
172
173
174
146
147
148
149
153
154
155
156
011
012
013
014
018
019
020
021
025
026
027
028
111
112
113
114
118
119
120
121
125
126
127
128
304 SS (316 SS Available)
Back, Bottom or Adjustable Angle connection.
3”, 4” or 5”
1/2” NPT Standard, (1/2” NPT Union available)
Slotted Hex Screw
Glass Standard, Plastic or Tempered Glass
optional
Hermetic Seal: Bi-Metal Thermometer per ASME B40.3
Stem:
304 SS, 0.375” O.D. (1/4” O.D. - specify
“DMT4”) Lengths from 2-1/2” to 36”
RTD-T/C Encapsulation Sleeve (Pat.pending): 304 SS
RTD:
100Ω (or 1000Ω optional) Platinum;
0.00385Ω/Ω/°C, 3-wire std.
Thermocouple: Type K grounded junction std. (Optional: types
T, E, J, or ungrounded.)
Description
MP Mini - Plug Receptacle (Thermocouple Only)
MC Mini - Connection Head, w/screw terminals &
protection head
EC 1/2" NPT Male Electrical Connection, w/Lead Wire
* available only with
3/8” dia. stem.
C03 -70 TO 70°C
C23 -40 TO 70°C
C55* 0 TO 50°C
0 TO 100°C
C43
C47 -20 TO 120°C
C53 -10 TO 110°C
0 TO 150°C
C59
0 TO 200°C
C65
0 TO 300°C
C69
C79 50 TO 400°C
C85** 100 TO 500°C
2.5
4.5
7.5
10.5
2.5
4.5
7.5
10.5
2.5
4.5
7.5
10.5
Table 5 - Output Connection
Code Degrees F Code Degrees C Code
F03 -100 TO 100°F
F23
40 TO 160°F
F55* 25 TO 125°F
F43
0 TO 200°F
F47
0 TO 250°F
F53
20 TO 240°F
F63
50 TO 300°F
F65
50 TO 400°F
F69
50 TO 550°F
F79 100 TO 800°F
F85** 200 TO 1000°F
1" NPT
15"
18"
24"
30"
36"
4"
6"
9"
12"
4"
6"
9"
12"
4"
6"
9"
12"
Aluminum screw - Cover Head w/3/4" NPT Conduit Connection
HA with Terminal Block
HT with 4-20 mA Transmitter (for Thermocouple)
HR with 4-20 mA Transmitter (for RTD)
Table 4 - Sensor
Code
Description
TK
TJ
TE
TT
UK
UJ
UE
UT
RC
RK
Thermocouple, Type K (grounded)
Thermocouple, Type J (grounded)
Thermocouple, Type E (grounded)
Thermocouple, Type T (grounded)
Thermocouple, Type K (ungrounded)
Thermocouple, Type J (ungrounded)
Thermocouple, Type E (ungrounded)
Thermocouple, Type T (ungrounded)
RTD, 100 ohm, 3-wire
max.
550°F
RTD, 1000 ohm, 3-wire
}
Connection:
T/C plug, Mini connection head, or Standard
screw-cover connection head are available,
Special customer requirements accommodated.
Ranges:
Std. REOTEMP ranges and divisions to 1000F
(500C)
Over Ranges:
50% over range to 550F, 1000F max.
Accuracy:
(+/-) 1% of full scale
Thermowell:
Model DMT fits any standard 0.385” bore
thermowell. (See table for Std. Models).
Options:
Silicone Case Fill for Vibration. (3/8” stem only)
NOTE: Model DMT is intended for use ONLY in a thermowell.
3-A and NACE conformity available.
9
Bimetal Thermometers
R E G I S T E R E D
OEM Dial Bimetal Thermometers
REOTEMP OEM Thermometers (Models Q, G, and H) are the perfect choice for equipment with limited space and
requiring a rugged, dependable and economical temperature sensor. Available with a wide variety of mounting threads.
Model H - 2 3/8” Dial
Model G - 1 11/16” Dial
Model Q - 1 5/32” Dial
.24
.17
.24
.24
.17
.33 dia
.33 dia
1/4" dia
1.16 dia
2.37 dia
1.70 dia
Stem
Length
Stem
Length
Stem
Length
.29
1/4" dia
1/4”
Dia.
1/4" dia
.30
.36
Mounting Thread Options
1/2” NPT
3/8” NPT
1/4” NPT
3/8-24 UNF
9/16” HEX
BUSHING
1/8” NPT
How to Order
QQ
Models
025
Stem
Length
2
Connection
OEM Models
025 = 2.5"
2 = Plain Bushing (std.)
040 = 4"
1 = 1/2" NPT
(1-3/4" dial)
060 = 6"
3 = 3/8-24 NF
HH = Model H
(2-3/8" dial)
090 = 9"
QQ = Model Q
(1-1/4" dial)
GG = Model G
(straight threaded)
4 = 1/4" NPT
120 = 12"
Lab & Test Models
QP = Model QP
(1-1/4" dial)
5" Stem
6 = 1/8" NPT
150 = 15"
7 = 3/8" NPT
180 = 18"
8 = Hex Reset Bushing
GL = Model GL
(1-3/4" dial)
8" Stem
HL = Model HL
(2-3/8" dial)
8" Stem
240 = 24"
300 = 30"
360 = 36"
-Intermediate
lengths available
up to 80"
-specify length in
inches + tenths
*-Other sizes available
F43
Temperature Ranges
(See pg 13 for full list)
Fahrenheit Ranges
-40 TO 160°F
25 TO 125°F
0 TO 200°F
0 TO 250°F
0 TO 300°F
50 TO 500°F
150 TO 750°F
200 TO 1000°F
Celsius Ranges
-40 TO 70°C
C23
0 TO 50°C
C55*
C43
0 TO 100°C
C47
-20 TO 120°C
C63
0 TO 150°C
C67
0 TO 250°C
C81
0 TO 400°C
C85
100 TO 500°C
Dual F/C Ranges
-40 TO 160°F & -40 TO 70°C
D23
25 TO 125°F &
0 TO 50°C
D55*
0 TO 200°F &
0 TO 100°C
D43
D47
0 TO 250°F & -20 TO 120°C
D63
0 TO 300°F &
0 TO 150°C
D67
50 TO 500°F &
0 TO 250°C
D81
150 TO 750°F &
0 TO 400°C
200 TO 1000°F & 100 TO 500°C
D85
F23
F55*
F43
F47
F63
F67
F81
F85
PS
Options
PS = Pointed Stem
SS = 316 SS Stem
PC = Plastic Window
PB = Plain Bushing
(non-reset)*
*for lab and test
Models only
*-Not available in model Q.
REOTEMP INSTRUMENT CORPORATION
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
10
Bimetal Thermometers
Hand-held Laboratory Thermometers
REOTEMP Laboratory Thermometers (QP, GL & HL) are ideal for testing and spot checking local temperatures in a
variety of critical process or lab applications. Pointed stems are available for insertion in semi-solids such as soil, meat, etc.
Model QP - 1 5/32” Dial
Model GL - 1 11/16” Dial
(with point - Model QPP)
Model HL - 2 3/8” Dial
(with point - Model GLP)
(with point - Model HLP)
.24
.24
.24
9/16" Hex
Re-set Bushing
1/4" dia
1.16" dia
9/16" Hex
Re-set Bushing
9/16" HEX
RE-SET BUSHING
1/4" dia
2.37" dia
1.70" dia
6"
Stem
1/4" dia
8" Stem
8"
Stem
.30
.30
.36
How to Order
Specify Model and Range (see table, pg. 10), Example: QP - F43
Bimetal Thermometers
Compost Thermometers
Applications
For Composting Food and
Yard Waste
Ideally suited for monitoring interior
temperature of compost bins or
windrows.
Used By:
Waste Treatment Plants.
City, State and Federal
Recycling Programs.
Farms and University
Compost Programs.
Compost Chicken, Hog
and Fish wastes.
Mushroom Farms.
Standard Model: A36 PF (36” Pointed Stem, 0/200° F)
Also Backyard Compost Thermometer:
G20P (2” Dial, 20” Stem, 0/200° F)
Standard Features
Hermetically sealed — will not fog
Pointed stem for easy insertion
Rugged, all stainless construction
Heavy duty 5/16” diameter stem
Easy to read 3” diameter dial
Unbreakable plastic crystal
°F & °C scales available
(Std. range, 0 - 200°F)
• Accuracy +/- 1% of scale
• Stem lengths up to 72” available
•
•
•
•
•
•
•
11
Sanitary Bimetal Thermometers
Sani-Temp
REOTEMP SANI-TEMP Bimetal Thermometer is specially designed for direct insertion into sanitary process applications when a standard thermowell
is not specified or the process environment is not exposed to pressure. The
SANI-TEMP provides a quick temperature response and will mate with existing process connections. The SANI-TEMP is ideal for the food, beverage
and pharmaceutical industries.
“C”
Dia.
•
•
•
•
•
•
Quick connect Tri-clamp design
Fast installation and removal
Hermetically sealed case
Ideal for CIP and SIP
Designed to meet 3A Sanitary standards
External Reset
Specifications
Sanitary Flange "C"
see chart
1 " dia
4
Thermometer
Head
Stem Length
Customer Specified
How
HowtotoOrder
Order
Flange
Type
Sanitary
Flange Sizes
Specify Sanitary Connection.
3” 4” 5”
316/316L polished stainless
300 series polished st. stl.
Tri-clamp (standard),
Cherry-Burrell (optional)
Windows:
Glass- (standard) see option
table
Optional:
Acrylic, Polycarbonate, or
Tempered Glass
Silicone Filling available for Vibration
Bimetal
Models
Stem
Lengths
Temperature Range
(See pg. 13 for a full list.)
Back
Connected
Use “How to Order” Codes on
pg. 4, 5, 6.
Dial Size:
Wetted Parts:
Case & Ring:
Process Connection:
Tri-Clamp
(standard)
M = 3/4"
C = 1" or 1 1/2"
A = 3"
C = 4"
B = 5"
2 1/2"
4"
See pg. 4
L = 2"
A = 2 1/2"
T = 3"
Bottom
Connected
XR = 3"
Y = 4"
VR = 5"
6"
9"
Other
Types
Available
See pg. 5
Celsius
F23 -40 TO 160°F
F55* 25 TO 125°F
F43 0 TO 200°F
F47 0 TO 250°F
F63 20 TO 240°F
F67
F81 50 TO 300°F
F85 50 TO 400°F
C23 -40 TO 70°C
C55* 0 TO 50°C
C43 0 TO 100°C
C47 -20 TO 120°C
C63
-10 TO 110°C
C67
C81 0 TO 150°C
C85 0 TO 200°C
12"
See pg. 6
Adjustable
Angle
L = 3"
M = 4"
J = 5"
Farenheit
15"
Other
Stems
Available
D23
D55*
D43
D47
D63
D67
D81
D85
Dual F/C Ranges
-40 TO 160°F
-40 TO 70°C
&
&
25 TO 125°F
-5 TO 50°C
&
0 TO 200°F
-10 TO 90°C
&
0 TO 250°F
-20 TO 120°C
&
20 TO 240°F
-10
TO 115°C
&
50 TO 350°F
10 TO 150°C
&
50 TO 400°F
10 TO 200°C
&
REOTEMP INSTRUMENT CORPORATION
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
12
Sanitary Bimetal Thermometers
Temperature Ranges
R E G I S T E R E D
Bimetal Temperature Range Master List - (Other ranges available on application. Y = available)
Code
F03
F07
F11
F21
F23
F Ranges Div Q G H 3,4,5**
-100/100F 2
Y Y
Y
-80/120F
2
Y
Y
-70/150F
2
Y
-40/120F
2
Y
-40/160F
2 Y Y Y
Y
F19
F31
F35
F55
F37
F39
F43
F45
F47
F53
F63
F65
F67
F69
F79
F81
F85
-50/300F
2
Y
-20/120F
2
Y
0/100F*
1
25/125F*
1 Y Y
0/140F
2
0/150F
1
0/200F
2 Y Y
0/220F
2
Y
0/250F
2 Y Y
20/240F
2
Y
50/300F
2 Y Y
50/400F
5
50/500F
5 Y Y
50/550F
5
100/800F 10
Y
150/750F 10 Y Y
200/1000F 10 Y Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
* = Minimum stem 4"
** Includes all 3", 4", and 5" models
(back, bottom, or all-angle)
Code
C03
C07
C11
C23
C Ranges
-70/70C
-50/50C
-50/100C
C19
C31
-40/70C
-50/200C
-40/160C
-20/40C*
C55
C37
0/50C*
0/60C*
C43
0/100C
C47
C53
C63
C65
C67
C69
C79
C81
C85
-20/120C
-10/110C
0/150C
0/200C
0/250C
0/300C
0/400C
50/400C
100/500C
DivQ G H 3,4,5**
Y
1
Y Y
Y
2
Y Y
Y
Code
Dual Ranges
D03 -100/100F & -70/40C
Q G H 3,4,5**
Y Y
Y
D11
-50/210F & -50/100C
Y
Y
Y
Y
D23
-40/160F & -40/70C
Y Y
Y
Y
1 Y Y Y
Y
D55
D37
D39
D43
25/125F
0/140F
0/150F
0/200F
&
&
&
&
-5/50C*
-15/60C
-20/70C
-10/90C
2
1
1
2
2
2
5
5
5
Y
Y
Y
Y
Y
Y
Y
D47
D53
D63
D65
D67
D69
0/250F
20/240F
50/300F
50/400F
50/500F
50/550F
&
&
&
&
&
&
-20/120C
-10/115C
10/150C
10/200C
10/260C Y
10/290C
1 Y Y Y
2
2
1
1/2
Y Y
Y Y Y
Y Y Y
Y Y Y
Y Y
Y
Y Y
Y
Y
Y
Y
Y
Y
Y
Y Y
Y
Y Y
Y Y
Y
Y Y Y
Y Y
Y Y
Y Y
Y Y
D81 150/750F & 70/400C
D85 200/1000F & 100/500C Y Y Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Bimetal Thermometers
Accessories
Accessories
AS-86 Adapter Kit: permits
installation of bimetal
thermometer in existing
mercury-in glass-industrial
thermometer thermowell.
HT
Heat Transfer Compound
(2 oz, 1 lb containers)
D3
Duct Flange (1/2" NPT)
CH
T-27 spring handle
CP
Pan Clip
Calibration
CC
Certificate of Conformance
C1
1 Point Calibration
Certificate
C3
3 Point Calibration
Certificate
Options
Code
MM
MA
TG
PC
SF
SD
GF
PS
3H
SS
F5
S3
F3
TF
MB
TS
TP
NL
BQ
Description
Minimum or Maximum
resettable pointer (one hand)
Minimum and Maximum
resettable pointer (two hands)
Tempered Glass Lens
Plastic Lens
Silicone Filled
Silicone Filled, food grade
Glycerine Filled
Pointed Stem
316SS Head and Bezel
316SS Stem
5/16” diameter stem
3/8” diameter stem
3/8” diameter aluminum sleeve
Teflon Coating (stem only)
External Mounting Brackets
Stainless Steel Tags
Paper Tags
No Logo Dial
BBQ Dial
Model
3”, 5”
3”, 5”
3”, 4”, 5”
All
3”, 4”, 5”
3”, 4”, 5”
3”, 4”, 5”
All
3”, 4”, 5”
All
3”, 4”, 5”
3”, 4”, 5”
3”, 4”, 5”
All
G, H
All
All
All
3”
Also available on request – Custom dials, special ranges, special configurations.
13
Thermowells
Threaded, for Bimetal Thermometers
R E G I S T E R E D
Thermowells make it possible to remove instruments without dropping pressure or losing contents. Each
stainless Thermowell die stamped with type of material from which it is made.
Type ST
How to Order
1.
2.
3.
4.
Type LG
“T” Lag
Extension
Type:
Thermometer Stem Length:
Material:
ST
External Thread:
M odels
Stem
"A" Dim
2 1/2"
4"
6"
ST
9"
12"
15"
18"
"A" Dim
6"
9"
LG
12"
(lagging)
15"
18"
24"
"U" Dim
1 5/8"
2 1/2"
4 1/2"
7 1/2"
10 1/2"
13 1/2"
16 1/2"
"U" Dim "T" Dim
2 1/2"
2"
4 1/2"
3"
7 1/2"
3"
10 1/2"
3"
13 1/2"
3"
19 1/2"
3"
Example:
4”
M aterial
304 SS
304 SS
External
Thread
3/4”
Options
3/4" NPT Socket-W eld
W ell
(Standard)
316 SS
Brass
Optional:
1/2" NPT
Tapered
Straight
Carbon
Steel
1" NPT
Santary
Tri-Clamp
.385 Bore
(for 3/8"
elements)
Sanitary Thermowells
Features
Provides Sanitary Protection for Temperature Probes
All 316L Stainless Steel Construction
Fast Installation & Removal
Ideal for Food, Beverage, Biotech & Pharmaceutical
Applications
• Finish Exceeds Ra 32 max.
• Exceeds 3A #4 Finish
•
•
•
•
How to Order
Specify Part Number:
Tri-Clamp "A" Stem
Size
Lengths
1 1/2"
1/2” MAX O.D.
2"
2 1/2"
.260
BORE
3"
2 1/2"
4"
6"
9"
2 1/2"
4"
6"
9"
2 1/2"
4"
6"
9"
2 1/2"
4"
6"
9"
Part No. "U" Dim
STF-1.5-2.5
STF1.5-4
STF1.5-6
STF1.5-9
STF2-2.5
STF2-4
STF2-6
STF2-9
STF2.5-2.5
STF2.5-4
STF2.5-6
STF2.5-9
STF3-2.5
STF3-4
STF3-6
STF3-9
1
2
4
7
1
2
4
7
1
2
4
7
1
2
4
7
5/8"
1/2"
1/2"
1/2"
5/8"
1/2"
1/2"
1/2"
5/8"
1/2"
1/2"
1/2"
5/8"
1/2"
1/2"
1/2"
REOTEMP INSTRUMENT CORPORATION
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
14
"C" Dim
(Flange Dia.)
2
(51mm)
2.5
(63mm)
3.6
(76mm)
4.7
(91mm)
Thermowells
R E G I S T E R E D
TYPES
Flanged Well
2-1/4
Standard Threaded Wells
U
INSERTION LENGTH
1/4"
1/4"
BORE
A
(.75)
1-1/4" dia
1.0
BORE DIA
Q
Q
(.50)
1/2" NPT
FLANGE SIZE & RATING
CUSTOMER SPECIFIED
P
U
A
ELEMENT LENGTH
Socket-Weld Well
Sanitary Well
A
U
1/8"
1-3/4"
3/8" DIA
1/4"
Q2
C
BORE SIZE
Q1
P
1/4"
1/2" NPT
1/2" NPT
(.250 DIA)
U
Standard Stepped Shank
A
SHANK STYLES
Tapered Shank
Q1
Q1
Q2
Q2
Straight Shank
Q
How to Order
Type
Material
Shank
Style
or (U-dim)
Order By Specifying:
1. Type and Bore Dia.
2. Thermometer Stem “A”
Length or “U” dimension.
3. Material.
4. Shank Style.
5. For Flanged Wells:
-Flange Size and Rating.
6. For Threaded Wells:
-Process Thread (P).
7. For Socket-Weld Wells:
-Nominal Pipe Size.
Element
Length
Externally Threaded
(Standard Bimetal Type)
Flanged
Socket Weld
Sanitary Type
See Table
pg. 14
304 SS
316 SS
Carbon Steel
Brass
316L SS
Monel
Hastelloy B
Hastelloy C
Titanium
Tantalum
Teflon
Stepped
Straight
Tapered
Flange
Wells
Socket-Weld
Wells
Flange Size
and Rating
Pipe Size
Nom.
Example:
1 1/2", 150#
Example:
3/4" Pipe
Call Factory for help
specifying well, if needed
15
Liquid-In-Glass Thermometer
All Angle Industrial
Specifications:
Case: Modern V-shape design with parts molded of GE Valox®
polyester, in black textured finish. Heavy glass protected front firmly
secured by spring action.
Stem: Tapered bulb chambers are made of precision ground aluminum. The tapered chamber forms a metal contact with matching
taper in the sockets assuring maximum speed of response to
temperature changes. Graphite is used as a conducting media
between bulb chamber and glass tube.
Locking Device: Adjustable case locknut and angle adjusting screw
work independently to provide full 360° positioning of thermometer
case and stem.
Tube & Capillary: Mercury filled-magnifying lens “Red Reading”
tube (Spirit Filled option available). Precision made to guarantee
accuracy within 1% of scale range. Silicone shock mounting for
lasting durability. When Mercury is not desired, alcohol-based spirit
fill is available
Scale: 9" scale with white coated aluminum and permanently baked
bold black markings.
Applications: REOTEMP “All Angle” Industrial Thermometers are
used in pipelines of all types, commercial building application
(heating & cooling), process piping, tanks, boilers, etc.
How to Order
9VX35
016
SOC35B
RETORT THERMOMETERS
For Rubber Vulcanizers, Retorts,
Coolers, Kettles.
9” Scale Straight or Angle Form,
3 ½” 304 SS Stem, with ¾ NPT 304 S.S. Hub.
INDUSTRIAL THERMOMETERS
9” Scale, All Angle with
1 1/4”-18” Swivel Nut
Stem
3 ½"
6"
9"
1. Part #
2. Range Code
3. Accessories
Part #
Mercury Filled Spirit Filled
9VX35
9VS35
9VX06
9VS06
9VX09
9VS09
Shaded items normally in
stock.
STANDARD
Code
Range
Divisions
411
118
212
012
016
318
324
330
-40 TO 110°F
-10 TO 180°F
-20 TO 120°F
0 TO 120°F
0 TO 160°F
30 TO 180°F
30 TO 240°F
30 TO 300°F
2°
2°
2°
1°
2°
2°
2°
2°
Range
Form
Part #
170/270°F & 0/30psi
170/270°F & 0/30psi
80/130°C & 0/2 kg/cm2
80/130°C & 0/2 kg/cm2
200/400°F & 0/200psi
200/400°F & 0/200psi
Angle
Straight
Angle
Straight
Angle
Straight
9RA35F
9RS35F
9RA35C
9RS35C
9RA35FV
9RS35FV
Separable Sockets
Extension
Stem Insertion
¾” NPT External
Length
Length
Neck
Length
Brass 304 SS
3 ½"
6"
9"
2 ½"
5"
8"
-
SOC35B SOC35S
SOC06B SOC06S
SOC09B SOC09S
6"
2 ½"
2 ½"
SEN06B SEN06S
5 ½"
2 ½"
¾ NPT External Thread
SEN09B SEN09S
U
A
U
1"
T
A
Union Hubs
9"
UH3B
REOTEMP INSTRUMENT CORPORATION
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
16
UH3S
Filled System Thermometers
Vapor Actuated
R E G I S T E R E D
REOTEMP remote Vapor actuated Thermometers
are manufactured to the highest standards for a
wide range of uses and may be fitted into almost
any temperature indicating application. These
instruments are ideal for remote reading, such as
panel installations, with capillary lengths of 1 to
100 feet.
Being vapor actuated, they are not subject to
indicator error due to ambient temperature variations along the capillary tube system, and will give
excellent readings provided the temperature being
measured is above or below ambient temperature.
Vapor instruments have progressive graduations,
and are best read in the upper 2/3 of the dial range.
Many ranges are available between –40°F and
+450°F, and care should be exercised to select a
range that will locate the operating temperatures
within the upper 2/3 of the dial range (see ranges on
back page).
Specifications:
Dial Sizes: 2", 2 ½”, 3 ½”, 4 ½”
Window: Polycarbonate, or Glass.
Dial: Aluminum with white finish and black markings, other
colors available.
Bulb: Stainless Steel or copper. Bulb O.D. 7/16"
(threaded), 3/8" (plain). Bulb lengths vary from 2 ½”
to 9 ¼” depending on capillary length.
Pointer: Standard adjustable.
Accuracy: Plus or minus one scale division.
Capillary: Copper, copper with bronze braid armor,
stainless steel, stainless steel with stainless steel
armor. Capillary lengths 1 to 100 feet (standard length
5 feet).
Case: All stainless steel, except: VA45FL (Aluminum)
VA45TB (Phenolic).
Ranges: Over twenty °F and °F/°C ranges available,
from –40° to + 450°F (see illustration, back page).
Process Connection: Plain Bulb, 1/2" NPT
Union, ½” NPT sliding union on 12" bendable extension, or
Thermowell. NOTE: Thermowells must be used whenever
the bulb would be exposed to pressure, fluid velocity, or
corrosive media
Applications: Control panels, chemical processing,
pipelines, food processing, OEM applications, ovens,
Movement: Brass with precision gearing.
Bourdon Tube: Phosphor bronze.
solar heating, refrigeration, etc.
17
Filled System Thermometers
Vapor Actuated - How to Order
Model V
Vapor
Actuated
Case Style
& Size
(Table 1)
Temperature
Range
(Table 2)
Capillary
& Bulb
(Table 3)
V
20FR
21
D
Capillary
Length (in Ft.)
(Table 4)
Process
Connection
(Table 5)
05
L2
Table 1 - Case Style
Front Flanged (Panel Mount)
Code Dial
Case
Lens
Connection Location
SS
SS
SS
SS
Polycarbonate*
Polycarbonate*
Polycarbonate*
Polycarbonate*
Rear
Rear
Rear
Rear
Black Aluminum
(hinge ring type)
Glass
Rear
Code Dial
Case
Lens
Connection Location
2"
20UR
25UR 2 1/2"
35UR 3 1/2"
SS
SS
SS
Polycarbonate*
Polycarbonate*
Polycarbonate*
Rear
Rear
Rear
Case
Lens
Connection Location
SS
SS
SS
SS
SS
Phenolic
Polycarbonate*
Polycarbonate*
Polycarbonate*
Polycarbonate*
Polycarbonate*
Glass**
Rear
Rear
Bottom
Rear
Bottom
Bottom (Turrent Mount)
20FR
25FR
35FR
45FR
2"
2 1/2"
3 1/2"
4 1/2"
45FL 4 1/2"
U-Clamp (Panel Mount)
Rear Flanged (Panel Mount)
Code Dial
20RR
35RR
35RB
45RR
45RB
45TB
2"
3 1/2"
3 1/2"
4 1/2"
4 1/2"
4 1/2"
Other Case Styles
*Glass lens available, specify “Glass Lens”
**Polycarbonate, lens available, specify “Poly Lens”
Code Dial
Case
Lens
Connection Location*
35SB 3 1/2"
45SB 4 1/2"
SS
Polycarbonate
SS
Polycarbonate
Adjustable Bracket
Mount
35DA 3 1/2"
45DA 4 1/2"
SS
Polycarbonate
SS
Polycarbonate
"Direct" adj. Mount
w/3.4 Cu bulb, 1/2" NPT*
*Specify Model & Range Only.
Example: V45DA-80
REOTEMP INSTRUMENT CORPORATION
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
18
Filled SystemThermometers
Vapor Actuated - How to Order
R E G I S T E R E D
*Ranges over 300° come with
316SS Capillary only.
Table 2 -- Temperature Ranges
°F and °C Ranges
Code °F Ranges Code
20
30
32
72
49
80
50
56
60
68*
70*
-40 TO 60°F
-40 TO 110°F
-20 TO 120°F
0 TO 180°F
0 TO 150°F
20 TO 220°F
40 TO 240°F
0 TO 250°F
30 TO 300°F
100 TO 350°F
200 TO 450°F
K2
L2
M2
-40 TO 60°F
-40 TO 110°F
-20 TO 120°F
0 TO 180°F
0 TO 150°F
20 TO 220°F
40 TO 240°F
0 TO 250°F
30 TO 300°F
100 TO 350°F
200 TO 450°F
21
31
33
73
79
81
51
57
61*
66*
71*
Table 5 -- Code
J1
Process
J2
Connection J3
Table 3 -- Capillary & Bulbs
Capillary & Capillary
Bulb Material Protection
Code
& -40 TO 15°C
& -40 TO 40°C
& -30 TO 50°C
& -20 TO 80°C
&
-15 TO 65°C
&
0 TO 105°C
&
0
TO 115°C
&
& -20 TO 120°C
& 0 TO 150°C
& 40 TO 175°C
& 100 TO 230°C
Copper
Copper
316 SS
316 SS
A
C
D
E
Table 4 -- Capillary Length
Specify Length in feet.
Standard Length = 5 Ft.
Available Capillary Length: 1-100Ft.
Note: Capillary Lengths over 5 feet affect bulb length.
See table at bottom of page.
Connection Type
Material
None (Plain Bulb)
Jam Nut Only
Brass - (For Existing Brass Well)
Jam Nut Only
316 SS - (For Existing Stainless Well)
1/2" NPT Union
Brass
1/2" NPT Union
316 SS
1/2" NPT Sliding Union on Bendable Extension 316 SS - (Only Avail. with 316 SS Capillary)
Brass
Thermowells
For Vapor
Actuated
Bulbs
(except M2)
None
Bronze Braid
None
S.S. Armor
316 SS
1/2 NPT
3/4 NPT
1/2 NPT
3/4 NPT
For 1-10 ft. Capillary (bulb #1)
12B
13B
12S
13S
For 11-25 ft. Capillary (bulb #2)
22B
23B
22S
23S
For 26-50 ft. Capillary (bulb #3)
32B
33B
32S
33S
For 51-75 ft. Capillary (bulb #4)
42B
43B
42S
43S
For 76-100 ft. Capillary (bulb #5)
52B
53B
52S
53S
Bulb Configurations
S
L
S
U
12"
D
D
Plain Bulb
D
L
U
D
S
Union Connection
Bendable Extension
Thermowell
Standard Bulb Dimensions (inches)
CAPILLARY
LENGTH
PLAIN BULB
L
D
1
1-10 ft. (bulb #1)
11-25 ft. (bulb #2)
26-50 ft. (bulb #3)
51-75 ft. (bulb #4)
76-100 ft. (bulb #5)
2 /2 (1-5ft.)
7
3 /16 (6-10ft)
7
/16
7
4 /8
7
7 /8
7
10 /8
3
3
3
/8
/8
3
/8
3
/8
3
/8
UNION CONNECTION
U
S
D
13
2
1
3
1 /16
/2
1
4 /2
1
6 /2
1
8 /2
2
3
/8
7
1
/4
1
5 /4
1
7 /4
1
9 /4
7
/16
/16
7
/16
7
/16
7
/16
THERMOWELL
U
S
D
15
1
/2
9
3
/8
3
5 /8
3
7 /8
3
9 /8
9
/16
2
5
3
1
/8
5
4 /8
5
6 /8
5
8 /8
2
/16
/16
9
/16
9
/16
9
/16
BENDABLE EXT.
S
D
1
2 /2 (1-5ft.) 3 - 13
3
/8
7
3 /16 (6-10ft) 4 - 14
L
7
/16
7
4 /8
7
7 /8
7
10 /8
3
4 - 14
3
5 - 15
3
8 - 18
11- 21
/8
/8
3
/8
3
/8
19
Filled System Thermometers
Vapor Actuated
Dial Faces
Typical dial faces shown below; complete list shown on page 19.
Operating temperatures should be in upper 2/3 of selected range.
C
No. 21
No. 31
F
No. 61
No. 73
C
No. 51
F
C
No. 66
F
C
No. 79
F
C
F
C
F
C
No. 81
F
C
F
For Temperatures above or below those shown, ask for information on REOTEMP Gas Actuated Thermometers.
Case and Mounting Dimensions (inches)
Front Flange
U-Clamp
Rear Flange
Dial Sizes
A
B
C
D
E
F
G
H
J
2"
2 1/2"
2.94
3.69
2.25
2.81
2.94
1.28R
1.66R
2.05
2.56
1.28R
2.3
0.14
0.17
3 1/2"
4.75
3.97
4.75
2.16R
3.59
2.16R
3.69
0.16
4 1/2"
5.88FR
6.31FL
5.88RR,RB
5.83TB
2.69R
4.59FR
47RR,
RB, FL
0.98
1
1.41RF
.75UC, FF
1.41RF
.75UC, FF
2.56TB
1.63FL
2.69R
4.69
0.22
REOTEMP INSTRUMENT CORPORATION
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
20
Filled System Thermometers
R E G I S T E R E D
Gas Actuated
REOTEMP Gas Actuated Thermometers
combine advanced gas coil technology with a
state-of-the-art adsorbent (Class IV) thermal
system, producing superior temperature measurement instrument that can be fitted to a
wide variety applications
Features include high accuracy, low ambient
error, no head error, and a high degree of
over-range protection. The compact (3/8” dia.
x 3” active length) bulb, and a wide range of
case styles and thermal systems, allow great
flexibility in installation.
The linear dial on all REOTEMP gas thermometers provides a consistent 1% accuracy
across the full span of each range. This,
combined with over twenty Fahrenheit and
dual ranges, from -320 F to +1200 F, provides
complete coverage of all normal temperature
requirements.
Specifications
Accuracy: +/- 1 % of full scale. Calibration to NIST
Windows: Glass is standard. Shatterproof glass
traceable standards.
and acrylic are optional.
Ranges: Twenty °F and °F & °C ranges available from
-320°F to 1200°F.
Pointers: Slotted adjustable type to permit zero-
Overrange: Minimum 50% of span above top of range,
or 1300°F, whichever is less.
Ambient Error: 1/4% of span per 25°F change in ambient temperature at midscale.
Dial Sizes: 41/2"& 6". Dials are white with black mark-
set adjustments.
Bulbs: 316 Stainless Steel, 3/8" dia. x 3" active
length. Other diameters and lengths are available.
Process Connections: Plain bulb; 1/2" NPT
sliding union; 1/2" NPT fixed (on All-Angle); or
thermowell. Note: Thermowells should be used
whenever the bulb would be exposed to pressure,
fluid velocity, or corrosive or abrasive media.
ings.
Thermal Systems: Stainless steel capillary with
Case Materials: Stainless steel, Phenolic,
or Aluminum.
stainless steel spring armor (up to 40ft).
Over 40 feet, stainless steel interlock armor is standard. Direct mount stems, 316 SS, 4" to 48".
Case Styles: Panel Mount, Surface Mount, or Direct
(stem) Mount.
21
Filled System Thermometers
Gas Actuated - How to Order
Table 1
Case Size
& Style
Table 2
Thermal System
& Bulb
Table 3
Capillary Length
(feet)
G
G
Table 5
Options
Table 4
Temperature
X
L
4
5
E
R
–
8 7
Table 1-Case Style
CASE
CODE
Wall Mount (“E” or “K” case)
A
G45ER
G45EL
B
“E” Case
Phenolic
Turret
Mount
–
L 1 5
–
CASE
DIAMETER CONNECTION
41/2"
41/2"
F B
–
X A W
Panel Mount (“F”, “S” or “U” case)
3 HOLES
G DIA. ON
H BOLT
CIRCLE
REAR
LOWER
“F” Case
Aluminum
D Front Flange
Hinge Ring
C
F
F
D
1
REAR
G60FR
6"
REAR
A
G45KR
41/2"
REAR
A
G45FR
3 HOLES G DIA. ON
H BOLT CIRCLE
E
A
“K” Case
S.S.,
Back
Flange
1
LOWER
G60KR
G60KL
6"
6"
REAR
LOWER
G45SR
41/2"
REAR
G60SR
6"
REAR
G45DA
41/2"
ADJUST
G60DA
6"
ADJUST
G45UR
41/2"
REAR
G60UR
6"
REAR
G45KL
C
3 HOLES G
DIA. ON
H BOLT
CIRCLE
/2"
4
/2"
4
B
.44
3 HOLES G DIA. ON
H BOLT CIRCLE
“S” Case
S.S.,
SemiFlush
Front
Flange
D
C
.75
B
Direct Mount (“D” case)
360°
ROTATION
“D” Case
S.S.,
All-Angle
Direct
Mount
B
E
A
F
B
“U” Case
S.S.,
D U-Clamp
A
180°
ROTATION
.88
PANEL .5 MAX THK
Case Dimensions
Case Size Case
Type
A
B
C
D
E
F
G
H
5.83
2.56
5.08
2.62
1.0
.20
.24
5.39
1.63
-
4.88
-
1.35
.19
5.38
2.15
5.04
-
-
-
0.22
5.38
41/2"
“E”
41/2"
“F”
Front Flange
6.31
41/2"
“K”
Back Flange
5.88
Turret Phenolic
41/2"
“S”
Semi-Flush
5.88
2.15
5.04
4.51
-
1.00
0.22
5.38
41/2"
“D”
All Angle
5.04
2.00
-
-
1.70
-
-
-
41/2"
“U”
U-Clamp
5.04
-
-
4.51
-
-
-
-
6"
“F”
Front Flange
7.87
1.59
-
6.34
-
1.75
0.19
6.69
6"
“K”
Back Flange
7.50
2.15
6.38
-
-
-
0.25
6.84
6"
“S”
Semi-Flush
7.50
2.15
6.38
5.88
-
1.00
0.25
6.84
6"
“D”
All Angle
6.38
2.15
-
-
1.70
-
-
-
6"
“U”
U-Clamp
6.38
-
-
5.88
-
-
-
-
REOTEMP INSTRUMENT CORPORATION
22
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Filled System Thermometers
Gas Actuated
R E G I S T E R E D
Table 2-Thermal Systems (all bulbs & capillaries are 316 SS)
CODE
DESCRIPTION
All Angle Direct Mount with 1/2” NPT
(with “D” case only)
Stem Length
All Angle Bulb
04
4” stem x 3/8” diameter
06
6” stem x 3/8” diameter
09
9” stem x 3/8” diameter
0X
12” or longer stem x 3/8” dia. - specify stem length
.38 DIA.
3"
Active Length
1/2" NPT
EXAMPLE: G45DA - 0X - 12” FB
#11 bulb
Plain Bulbs
11
BULB/316, S.S.
.38 DIA. EXT/316, S.S.
.38 DIA.
Plain bulb, 3/8” x 3” active, + 12” rigid
extension
ARMOR
#12 bulb
12"
3"
Active Length
ARMOR
.38 DIA.
12
Plain bulb, 3/8” x 3” active
REINFORCING
SPRING, S.S
Sliding 1/2” NPT on
Bendable Extension
3"
Active Length
Bendable Extension
1/2" NPT
87
3/8” x 3” active, 12” bendable extension
88
3/8” x 3” active, 18” bendable extension
8X
3/8” x 3” active, over 18” bendable (Specify)
.38 DIA.
3"
Extension Length
Active Length
Table 3-Capillary Length
Specify Armored Capillary Length in Feet, up to 99 ft. (omit for “D” case).
L05 = 5 feet
L10 = 10 feet
L15 = 15 feet…etc.
Note: Stainless steel spring armor is standard protection on all capillary. Capillary over 40 feet requires XSI Spiral Interlock Armor option.
Table 4-Temperature Ranges
CODE
FB
FE
FG
FH
FJ
FL
FN
FP
FR
FT
°F RANGES
DIV.
CODE
-320/100°F
-120/120°F
-40/180°F
0/120°F
60/120°F
20/240°F
0/300°F
50/550°F
50/750°F
400/1200°F
5°
2°
2°
1°
1°
2°
5°
5°
5°
10°
DB
DE
DG
DH
DJ
DL
DN
DP
DR
DT
°F & °C RANGES
-320/100°F / -200/40°C
-120/120°F / -85/50°C
-40/180°F / -40/80°C
0/120°F / -15/50°C
60/120°F / 15/5°0C
20/240°F / -5/110°C
0/300°F / -10/150°C
50/550°F / 10/290°C
50/750°F / 0/400°C
400/1200°F / -200/650°C
DIV.
5°/2°
2°/1°
2°/2°
1°/1°
1°/1/2°
2°/1°
5°/1°
5°/5°
5°/5°
10°/5°
Note: °C Ranges available on request
23
Filled System Thermometers
Gas Actuated
Table 5 - Accessories & Options
Code
Description
XAW
Acrylic Window (41/2" Cases only; not available in “F” Case).
XSG
Safety Glass Window (41/2" Cases only; not available in “F” Case).
XMH
Maximum or Minimum Hand.
XMM
Maximum and Minimum Dual Hands.
XFR
Flush Mounting Ring for “E” Case.
XBF
1/2" NPT Fitting for #11 Bulb - Fits on Bulb or extension.
XCF
1/2" NPT Fitting - Fastens on spiral interlock armor (requires XSI option).
XSI
Spiral Interlock Armor (required over 40 feet).
XVD
Vibration Dampening feature (dampens vibration - available in all rear connected models).
XTW
Thermowell (see thermowell table below for order codes).
Thermowells for 3/8” dia. Elements
Lagging Wells
Standard Wells
External
Thread
P
3/4" NPT
1" NPT
Stem
length
A"
Insert
Length
U"
Order
Code
304 s.s. 316 s.s.
4
6
9
12
15
18
24
2 1/2
4 1/2
7 1/2
10 1/2
13 1/2
16 1/2
22 1/2
046
047
048
049
050
051
052
146
147
148
149
150
151
152
4
6
9
12
15
18
24
2 1/2
4 1/2
7 1/2
10 1/2
13 1/2
16 1/2
22 1/2
053
054
055
056
057
058
059
153
154
155
156
157
158
159
External
Thread
P
Stem
length
A"
Insert
Length
U"
Lag
Ext.
T"
3/4” NPT
6
9
12
15
18
24
2 1/2
4 1/2
7 1/2
10 1/2
13 1/2
16 1/2
2
3
3
3
3
3
Order
Code
304 s.s. 316 s.s.
247
248
249
250
251
252
STEM LENGTH A
1
/2" NPSM
STEM LENGTH A
.385 DIA
1
/2" NPSM
How to Order
Specify “TW” Plus Order Code
Example: TW-146
REOTEMP INSTRUMENT CORPORATION
24
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
347
348
349
350
351
352
Filled Systems Thermometers
Direct Drive Gas Actuated
R E G I S T E R E D
Available in Four styles
45GW
45GF
45GFF
45GAW
WALL MOUNTED
FLUSH MOUNTED
FRONT FLANGE
ADJUSTABLE WALL
Specifications
CASE:
Stainless Steel (SS)
DIAL FACE:
4 1/2" Satin Finish Aluminum, Black Lines and
Numbers.
Gasket Sealed Glass (Plexi Glass Optional)
Micrometer Adjustment Type
LENS:
POINTER:
CAPILLARY:
SS Protected by 1/4" Dia. Flexible SS Armor or
3/16" Dia. Plain Armor
BULB:
SS Welded Construction
ACTUATION:
Nitrogen thru SS Direct Drive Bourdon Coil
ACCURACY:
+/- 1 % of Range Span
REOTEMP’s Rugged Direct Drive System makes our 45G series
gas – actuated series the right choice for temperature indication in
heavy duty or high vibration applications.
Its all-stainless steel case and internals, along
with the direct drive system, result in superior
instrument life in severe environments.
NITROGEN FILLED
DIRECT DRIVE SYSTEM
Temperature Ranges
Celsius Ranges
00
01
02
04
05
06
07
08
09
10
11
12
13
14
39
-200/100°C
-100/100°C
-30/60°C
-10/80°C
-30/120°C
-10/150°C
0/100°C
0/200°C
0/240°C
0/300°C
0/400°C
100/400°C
0/500°C
0/600°C
0/50°C
Fahrenheit Ranges
16
17
19
20
21
23
24
25
26
27
30
31
32
33
34
36
38
-350/150°F
-100/100°F
-40/120°F
-40/200°F
0/100°F
0/150°F
25/125°F
0/200°F
0/240°F
0/300°F
0/400°F
0/500°F
0/600°F
150/750°F
0/800°F
0/1200°F
20/240°F
25
Filled Systems Thermometers
Direct Drive Gas Filled Remote
Case Specifications
Model 45GAW
Model 45GW
Adjustable Wall Mounted
Complete with Flange
Wall Mounted
Complete with Bracket
Model 45GF
Model 45GFF
Flush Mounted Complete
with U - Bracket
Flush Mounted Complete
with U - Bracket
Bulbs
G1
G2
12”
3/8” dia. bulb with 3/16” bendable complete with 1/2” NPT
compression fitting; All SS
3/8” dia. bulb with 3/8” extension up to 48” with
optional 1/2” NPT compression fitting; All SS
How to Order
45GW
Model
06
Armored Capillary Temperature
Length
Range
45GW =
Wall Mount
05 = 5 Feet
45GF =
Flush Mount
06 = 6 Feet
45GFF = Front Flange
45GAW = Adjustable
Wall Mount
08
10 = 10 Feet
Other = Specify Length
in Feet
See chart on
Page 25.
G118
Bulb Type
G112 = 12" Bendable Extension
with 1/2" NPT Union
G118 = 18" Bendable Extention
with 1/2" NPT Union
G212 = 12" Plain Bulb with Rigid
Extension
G224 = 24" Bendable Extension
with 1/2" NPT Union
45SG
Accessories
for Thermowells see pg. 24
EC = Electrical Contacts
MP = Max Hand Pointer
SG = Tempered Glass
PC = Polycarbonate
Crystal
REOTEMP INSTRUMENT CORPORATION
26
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Filled Systems Thermometers
Direct Drive Gas & Liquid Filled
R E G I S T E R E D
REOTEMP’s Rugged Direct Drive System
makes our 45GR and 45LR the right choice for
temperature indication in heavy duty or high
vibration applications. Its all-stainless steel
case and internals, along with the direct drive
system, result in superior instrument life in
severe environments.
EVERY ANGLE
MODEL
45LR
Specifications:
CASE:
DIAL FACE:
LENS:
POINTER:
BULB:
Stainless Steel (SS)
4 1/2" Satin Finish Aluminum, Black Lines and Numbers
Gasket Sealed Glass (Polycarbonate Optional)
Micrometer Adjustment Type
SS Welded Construction
ACTUATION: 45 LR - Inert Liquid thru SS Direct Drive Bourdon Coil (For
*ranges, Nitrogen thru SS), Direct Drive Bourdon Coil.
45GR - Nitrogen thru SS Direct Drive Bourdon Coil.
MODEL
45GR
ACCURACY: +/- 1 % of Range Span
How to Order
45GR
Model
45GR = Gas Actuated
3/8" Stem
45LR = Inert Liquid
Actuated, 1/4" Stem
06
ST6 316
08
Armored
Temperature
Capillary Length
Range
Accessories
02 = 2 1/2" (LR Only)
Standard Thermowells (3/4"NPT, 316SS)
04 = 4"
Stem
"U"
1/4"
06 = 6"
Length
Dim.
element
element
09 = 9"
4"
2.5"
ST4316
GXTW146
6"
4.5"
9"
7.5"
ST6316
ST9316
GXTW147
GXTW148
p. 14
p. 24 )
12 = 12"
15 = 15"
See chart on
Page 25.
(More wells on:
3/8"
EC = Elec. Connection SG = Tempered Glass
MP = Max Pointer
PC = Plastic Crystal
27
Digital Thermometers
Hand-Held Thermometers
Durable, shock
resistant ABS
plastic carrying
case
Easy-to-read,
backlighted
LCD displays
both °F
and °C
Model 701K - Pocket Size
Magnet on back - stick it anywhere
In Stock in °F; Also available °C.
Sealed
membrane
touch pad
Features
•
•
•
•
Features
Model TM99A
All Solid State
(with disposable battery)
High Accuracy
Model TC100A
(with rechargeable battery)
Detachable Probes
Wide Temperature Ranges
Accuracy
Ambient Range
Display
Probe
Size
Model HI 9063
HI 9063
Greater of ±0.3 F, or ±0.5% of reading
0 To 150 F max, RH -90%, noncondensing
Backlighted .4" LCD
#1075 10K Thermistor, detachable
Type K Thermocouple
TM99A - 9V alkaline battery (provided)
4 - 1.5V AAA batteries
TC100A - 9V NiCad battery with 110V charger
9 1/2" x 6 1/2" x 2 1/2" (case closed)
7.7" x 3.1" x 2.4" (196 x 80 x 60mm)
1. Specify Model #.
2. Specify Probe.
Model #
701K
Hand-Held
Thermometer Models
Thermistor
Models
Disposable Battery
1075
TC100A Rechargable Battery
"K" Thermocouple
Models
4040
Compact
HI9063
Full Functioned
Probe
SPK1
Probes for Models:
TM99A and TC100A
10K Thermistor Probes
All but 2010 and 7041 have 3”
handle and 48” coiled lead.
Probe
Model Description
Dimensions
1052
701K
Type K Thermocouple (Optional)
1 - 9V battery
3.1" x 2.4" x 1.1" (80 x 60 x 33.5mm)
Probes for Models:
How to Order
TM99A
701KF
C/LO Mode: -50 TO 150 C with 0.1 C Resolution
C/HI Mode: -50 TO 950 C with 1 C Resolution
-50 To 1,000 F with 1 F Resolution
F/LO Mode: -58 TO 302 F with 0.1 F Resolution
F/HI Mode: -58 TO 1742 F with 1 F Resolution
±0.3% Full Scale / ±3 C (hi), ±0.6 C (lo)
±.25%* (±1 Digit)
-10 TO 50 C (14 To 122 F) RH 100%
32 TO 104 F
-40 F TO +300 F
(-40 C TO +150 C)
0.1 F or C Resolution
Range &
Resolution
All Solid State
High Stability
Cold Junction Compensation
Wide Temperature Ranges
Water Resistant Min - Max, °F/°C
TM99A
TC100A
Specifications:
Power
•
•
•
•
5005
2010
S/S Immersion
(comes standard)
S/S Piercing
Tip Probe
Fast Surface
Probe
Air Probe
General Purpose
Probe
HI 9063 and 701KF
Thermocouple Probes (intermediate sizes, or
industrial configurations avalaible on application)
Probes have 4” handle and min. 36” lead, except
where noted.
Probe
Model
Description
Dimensions
LPK5
XPK2
Immersion/General
Purpose
Fast Response (no
handle)
Fast Response
Piercing Tip
.142" x 4"
FRK4
HPK2
REK1
.041" x 2.8"
SPK1
Surface Temperature
LPKA
Gas Temperature
LPK12
Heavy Duty General
Purpose
.125" x 4"
.18" x .6"
Soft-wire Disposable
(no handle)
.156" x 5"
1/16" x 12"
1/16" x 4"
.156" x 4"
exposed tip 48"
MRK36, Heavy Duty
.40" x 36", 48" or 60"
48,60
Penetration (pointed)
REOTEMP INSTRUMENT CORPORATION
28
1/4" x 12"
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Thermocouples & RTD’s
R E G I S T E R E D
RTD’s (Resistance Temperature Detectors)
How
Howto
toOrder:
Order
Construct part number from table D below.
For Thermowell Assembly:
Insert part number obtained below into assembly part number on page 31.
RTD Styles
TABLE D
Resistance Temperatures Detectors
STEP 1 - RTD Style
A
B
A standard RTD Assembly may be supplied with
an adjustable compression fitting. Specify.
Welded
Choose from “Styles” table. Insert letter below. (for thermowell assemblies, specify style “A”)
STEP 2 - Sensor Material (Px is standard)
1
/2 NPT Std.
B
B
A standard 1/2 x 1/2 NPT stainless bushing is welded to
the element sheath. 1/4 x 1/4 and 3/4 x 3/4 are available.
Specify.
Insert letter designated below.
Px - Platinum 0.00385 Ω/Ω/°C
P - Platinum 0.00392 Ω/Ω/°C
Pl - Platinum 0.00390 Ω/Ω/°C
N - Nickel 0.06725 Ω/Ω/°C
C - Copper 000421 Ω/Ω/°C
Ba - Balco
STEP 3 - Temperature
Insert single-digit number designated below.
1 (standard) -200 / +400°F (-130 TO +200°C)
2 (hi temp) -200 / +1100°F (-130 To +600°C)
C
A quick-disconnect male plug is mounted on the cold
end of the element. Two or three prong standard plugs
are available. Two prong miniature plugs are
available. Specify.
Special Ranges available on
application
STEP 4 - Sheath Diameter
Insert two-digit number designated be designated below.
18 = .188 dia.
25 = .250 dia.
37 = .375 dia.
STEP 5 - Sheath Material
D
A quick-disconnect female jack is mounted on the
cold end of the element. Two or three prong standard
jacks are available. Two prong miniature jacks are
available. Specify.
Insert single-digit number designated below.
1 = 316 SS
3 = 304 SS
5 = INC 600
STEP 6 - Resistance 32°F (0°C) Ohms ±.5% (#1 IS STANDARD)
Insert single-digit number designated below.
(STD) Platinum - 1 = 100 Ohms 2 = 200 Ohms 5 = 500 Ohms
Nickel 7 = 120 Ohms
Copper 8 = 10 Ohms
E
STEP 7 - Determine the required length “L” in inches
For Thermowell assemblies, specify “AR” (as required)
This RTD is terminated with an “O” ring seal.
Canister Head.
STEP 8 - Number of Leads/RTD’s
Spring Loaded
1
/2 NPT Std.
H
B
A standard 1/2 x 1/2 NPT stainless hex bushing allows
the element to be spring-loaded up to 1/2.
Single RTD
W
X
Y
Leads/RTD
2-wire
3-wire
4-wire
Duplex RTD
WW
XX
YY
STEP 9 - Lead Length
Need something you don’t see?
Call REOTEMP for information.
•1-800-648-7737•
Specify lead length “B” in inches.
(Omit for T/W assemblies, or where N/A)
29
Thermocouples & RTD’s
Mineral Insulated Thermocouples
TABLE C
Thermocouples
STEP 1
Metal Sheathed Thermocouple Assembly - Insert “M”
How
HowTo
to Order:
Order
Construct part number
STEP 2 - Sheath Diameter
Insert 2 digit number designated below.
12 = .125in.
18 = .188in
from table “C”.
25 = .250 in.
37 = .375in.
STEP 3 - ANSI Type Thermocouple Element
Insert designation below.
K = Chromel Alumel
T = Copper Constantan
J = Iron Constantan
E = Chromel Constantan
For Thermowell
Assembly:
Insert part number
obtained below into
assembly part number
on page 31.
STEP 4 - Type of Sheath Material
Insert single-digit number designated below.
1 = 316 SS 1700°F (927°C)
3 = 304 SS 1650°F (899°C)
2 = 310 SS 2100°F (1149°C)
5 = Inconel 600 2100°F (1149°C)
STEP 5 - Style
Choose style from “Styles Table”. Insert letter(s) below. (For thermowell
assemblies specify “A”)
STEP 6 - Number of Element
S = Single element assembly
D = Dual element assembly
STEP 7 - Type of Junction
Elements:
G = Grounded
U = Ungrounded
STEP 8 - Probe Length
Length “L” in inches. For complete assembly with
thermowell specify “AR” (as required).
STEP 9 - Specify Lead Length
“B” in inches (omit for thermowell
assemblies, or where n/a)
M
Thermocouple Styles
Thermocouple Styles
A
B
Plain sheath with wire leads. Cold end epoxy sealed.
Choose this style for Thermowell assemblies.
Welded
1
D
Female Mini-plug is mounted to cold end of sheath.
Standard size plug available (specify).
/2 NPT Std.
Spring Loaded
1
/2 NPT Std.
B
B
A standard 1/2 x 1/2 NPT stainless bushing is welded to
the element sheath.
C
Male Mini-plug is mounted to cold end of sheath. Standard
size plug available (specify).
H
B
A standard 1/2 x 1/2 NPT stainless bushing allows the
element to be Spring Loaded up to 1/2".
Need something you don’t see?
Call REOTEMP for information.
•1-800-648-7737•
REOTEMP INSTRUMENT CORPORATION
30
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Thermocouples & RTD’s
Thermowell Assemblies
R E G I S T E R E D
How to Order
Screw
Cover Head
Table A
Below
Example:
B
Threaded
Connection
Table B
Below
–
1
L
–
M 25 K
3
TABLE A
Screw Cover Heads
UNIVERSAL CAST IRON
TYPE A
•
•
•
•
Thermowell
Table E (p.32) optional
Probe Element
Thermocouples - Table C (pg.30)
or RTD’s - Table D (pg.29)
Universal head
Cast iron
Heavy Duty
1/2 NPT process with 3/4 NPT
conduit is standard
UNIVERSAL CAST ALUMINUM
A
S
G AR
–
TABLE B
S T 4
3 0 4
Threaded Connection Configuration
CONFIGURATION: Dimensions are approximate.
(with thermowell, sheath
length “L” does not have to
be specified)
TYPE B
Stems are spring loaded*
for positive contact with
bottom of thermowell.
Standard
Steel
Fittings
316 SS
Fittings
1L
1T
2L
2T
3L
3T
4L
4T
Head-Bushing
• Universal head
• Cast aluminum
• 1/2 NPT process with 3/4 NPT
conduit is standard
L
5
115/8"*
/8" (Nominal)
Head-Nipple
FDA WHITE POLY
TYPE S
• Screw cover Poly head
• Impervious to most
corrosive media
• 1/2 NPT process with 3/4 NPT
conduit
• SS Chain & Screws
2-1/2"*
21/2" (Nom.)
L
Head-Nipple-Union
3"*
3" (Nom.)
EXPLOSION PROOF
TYPE E
• Explosion Proof
• Cast aluminum
body & cap
• For use with two wire transmitter
• Rated for Class I, Groups C, D,
Class II, Groups E, F, G, Class III
• 1/2 NPT process with 1/2 NPT
conduit is standard
Transmitters
- Specify 4-20mA transmitter by
adding “X” to head type.
Example:
Type B head with Transmitter =
BX (specify Temp. Range)
Terminal Blocks - Standard in all heads.
L
Head-Nipple-Union-Nipple
5”
5"*(Nom.)
L
* For welded SS fittings, substitute”F” for “T”
Example: 1F
Also Available:
•
•
•
•
•
Thermocouple Wire
Transmitters
Multipoint Thermocouple Assemblies
Protection Tubes
Stainless Steel Fittings
31
Thermocouples, RTD’s & Accessories
Finished Assemblies - Ready to Go
Popular Thermocouple & RTD Assemblies
• Type K or J Thermocouple (single element, ungrounded)
• Weatherproof Cast Aluminum Screw Cover Head,
with Terminal Block
• 316 SS Bushing, or steel Nipple
• 1/4" dia. 316 SS Spring-loaded Stems, 4"’ 6"’ 9"’ or 12 “
• Available for fast delivery
Head-Bushing Assemblies
Head-Nipple-Union-Nipple Assemblies
L
Thermocouples
Thermocouples
Stem (L)
4"
6"
9"
12"
Type K
Type J
B1TM25K1ASU4
B1TM25K1ASU6
B1TM25K1ASU9
B1TM25K1ASU12
B1TM25J1ASU4
B1TM25J1ASU6
B1TM25J1ASU9
B1TM25J1ASU12
Stem (L)
4"
6"
9"
12"
Type K
Type J
B2LM25K1ASU4
B2LM25K1ASU6
B2LM25K1ASU9
B2LM25K1ASU12
B2LM25J1ASU4
B2LM25J1ASU6
B2LM25J1ASU9
B2LM25J1ASU12
RTD’s (3-wire, 100 ohm)
Stem (L)
Model #
B2TAPX125114X
4"
B2TAPX125116X
6"
B2TAPX125119X
9"
12"
B2TAPX1251112X
RTD’s (3-wire, 100 ohm)
Stem (L)
4"
6"
9"
12"
L
5"*
1 5/8"*
Model #
B1TAPX125114X
B1TAPX125116X
B1TAPX125119X
B1TAPX1251112X
R E G I S T E R E D
Table E Thermowells - Common Threaded Thermowells (3/4"NPT external thread).
Stem
Length
"U"
Dim
4"
6"
9"
2 1/2"
4 1/2"
7 1/2"
1/4" DIA. ELEMENTS
304 SS
316 SS
ST4304
ST6304
ST9304
ST4316
ST6316
ST9316
For other similar wells, see complete listing, p. 14.
Stem
Length
"U"
Dim
4"
6"
9"
2 1/2"
4 1/2"
7 1/2"
3/8" DIA. ELEMENTS
304 SS
316 SS
GTXW046
GTXW047
GTXW048
GTXW146
GTXW147
GTXW148
For other similar wells, see complete listing, p. 24.
Field- Cuttable Thermocouples & RTD’s
• Adjustable probe length, 2.5" to 18"
• Probe is cut with simple tube cutter
• One size fits many - simplify inventory.
How to Order
Thermocouples, Specify:
1. Model (TC-1350 or RTD-1340)
Other Accessories:
2. Sensor type (K, J, T, E, Etc.)
Description
Model #
Description
3. G (grounded) or U(ungrounded) Model #
Example:
TC-1350-K-G
Cast
Iron
Head
Terminal
Block, 2-wire
TCX 006 A
TCX 001 T2
TCX 006 B Cast Aluminum Head
TCX 001 T3 Terminal Block, 3-wire
How to Order
TCX BSL 22 Spring loaded Bushing TCX 001 T4 Terminal Block, 4-wire
RTD’s, specify Model only.
TCXT4
2 Wire Temperature Transmitter, 4-20 mA (specify calibration)
Example:
RTD-1340
REOTEMP INSTRUMENT CORPORATION
Telephone: (800) 648-7737 FAX (858) 784-0720 · [email protected] · www.reotemp.com
32
Thermocouples & RTD’s
CIP Sanitary RTD’s
ROETEMP’s Santary RTD’s are designed for temperature sensing in food,
dairy, beverage and pharmaceutical
applications where sensor corrosion
and product contamination are critical factors.
Features:
• Ideal for CIP (Clean-in-Place)
• All Sensors Highly Polished to Exceed 3A Requirements
• Quick-Connect Tri-Clamp Design
• Fast Response Tip Available
• Variety of Stem and Termination Options
Stem Options
Termination Options
Connection Head Types S, Y (or Type T w/transmitter)
Standard Stem Type A
Immersion
X
3”
Sensitive
Portion
1/2”
FDA Compliant
White Polypropylene Screw Cover
Head (Standard)
1/4” OD, 316L SS
S/S Sanitary Cap
Reduced Tip Stem Type B, C, E
Immersion
X
3”
1 1/4”
316L SS
Type L (with Teflon Leads)
E
Lead Length
(STD. = 6”)
2 1/4”
S/S Sanitary Cap
1/2” NPT
Type D Mini-Stem with T-75 Mini-Cap
Type N (with Teflon Leads)
4 1/2”
5/32” OD
3/4”
Tri-Clamp
All Stems are Polished 316L SS
E
Lead Length
(STD. = 6”)
2 1/4”
X
Other Options Available
See Easy “How to Order” guide on page 34.
33
Thermocouples & RTD’s
CIP Sanitary RTD’s
How to Order
R
L3
030
A
T15
L 12
Table 1 - RTD Type
α 3 wire
100 ohm; .00385µ;
Table 5 - Termination
Description
Accuracy # Elements
1
L3 = 0.10%
1
H3 = 0.01%
2
L6 = 0.10%
2
H6 = 0.01%
Maximum temperature: 400°F (204°C)
Table 2 - Immersion Length (X)
Length
Length
020 =
060 =
2"
6"
3"
9"
030 =
090 =
4"
12"
040 =
120 =
Long or intermediate lengths OK
Please specify length
Table 3 - Stem Style (All stems hightly polished to exceed 3-A#09-08).
A=
Description
1/4" Diameter
B=
Reduced Tip (3/16" tip OD X 3/8" sheath OD)
C=
Reduced Tip (1/4" tip OD X 1/2" sheath OD)
D=
5/32" Diameter Tip (with T75 mini-cap only)
Single Element Only
E=
Special HTST Fast Response Reduced Tip (3/16
tip OD X 3/8" sheath OD, response time 3 to 3.5
sec.) Available in H3 & H6 RTD Type Only.
S=
Std. White Polypropylene
Connection Head (FDA Compliant)
T=
White Polypropylene Connection
Head with 4-20ma Transmitter
Y=
White Epoxy Coated Aluminum
Head
L=
1/2" OD 316SS transition with (E")
Teflon Leads (Specify Length, e.g.
12" =L12 )
N=
1/2" NPT 316SS Threaded Fitting
with Teflon Lead (Specify Length,
e.g. 6" =N6)
See stem options table pg. 33
Other Available Options:
• Alternate Wire Termination
• Alternate Sanitary Cap Styles
• Digital Indicating Meters (Suitable for Washdown)
• Thermocouple Sensors (Sanitary & Industrial)
(See Termination
Options pg. 33)
Table 4 - Sanitary Cap
Tri-Clamp Caps (Triclover 16 AMP Type)
Description
T15 = 1.5" (Standard)
T20 = 2"
T30 = 3"
T75 = 3/4" Fractional (with "D" stem only)
Other Cap Styles Available - Please Specify
•
•
•
•
RTD’s with CIP Sanitary Connected Wells
Penetration Probes
Chemical Resistant Thermocouples
Stainless Steel Tags
Other REOTEMP CIP Sanitary Products
Sanitary Pressure
Gauges
Sanitary Thermowells
Sanitary Bimetal
Thermometers
Sanitary Pressure
Transmitters
REOTEMP INSTRUMENT CORPORATION
34
Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com
Bimetal Thermometers
Surface Thermometers
R E G I S T E R E D
• Measures Temperature of any
Specifications
•
Accuracy - Within 2% of full scale
Head - 2” (5.08cm)
Dial - White Background, blue marks &
numbers
Height - 1/2” (1.27cm)
Weight - 2 ounces (56.7G) approx.
Case - aluminum with optically clear
crystal
Sensing Element - precision calibrated
bimetal coil
Response Time - approximately 1 minute
Mounting - two Alnico magnets on back
•
Horizontal Surface
Magnetic Feet hold to any Ferrous
Surface
Used on Griddles, Ovens, Motors,
Piping, Tanks, etc..
Front View
Magnets
How
Order
How
to to
Order
Model #
Temperature Ranges
SUR-15
SUR-50
SUR-25
SUR-75
0 to 150°F/-20 to 65°C
0 to 500°F/-20 to 260°C
0 to 250°F/-20 to 120°C
50 to 750°F/10 to 400°C
Protecitive
Cover and
Heat Collector
Bimetal
Sensing
Element
Back View
Bimetal Thermometers
Pocket Thermometers
Analog (Dial) Models
Digital Pocket Thermometer
Model K-79
Model D-450
•
•
•
•
•
•
•
•
•
•
•
•
Accurate & Rugged
Quick Response
Shock Resistant
Sensitive Bimetal Element
External Reset Adjustment
Waterproof and Dustproof
Stainless Steel or Plastic Pocket Case
Resolution 0.1°F
Stainless Steel Stem, .14 x 5”
Accuracy 1% of span
Comes with Pocket Case
1/4” High LCD Display
Also Available: D-302, -58 to 320°F
Specifications
Digital Specifications
Model #
Accuracy - 1% of Scale
Head - 1” Diameter (25mm)
Dial - White Background with crisp
letters, marks, and numbers.
Stem - .142 OD, 5” long, pointed
(3.6mm x 127mm)
Reset Nut - 7/16” Hex (11mm)
Pocket Case - Stainless Steel or
Plastic with Clip and Holder Loop
Weight - .65 ounces (18.5G)
Packed - 1 per box, 12 per carton
Analog
K-79-2
K-79-3
K-79-4
K-79-5
K-79-7
K-79-8
K-79-9
Digital
D-450
D-302
Temperature
Ranges
-40 to 160°F
0 to 220°F
25 to 125°F
50 to 550°F
-10 to 110°C
0 to 150°C
0 to 250°C
Range
Resolution
Accuracy
Display
OFF Function
Update
D-450
D-302
-40/450° F
0.1° F
± 0.8% of span
¼” LCD
50 Min. Auto
10 Seconds
-58/302° F
0.1° F
± 1% span
¼” LCD
Manual
4 Seconds
-40 to 450°F
-58 to 302°F
35
How to