reotemp
Transcription
reotemp
REOTEMP INSTRUMENT CORPORATION Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com Table of Contents Bimetal Thermometers General Bimetal Specifications 3”, 4” & 5” Back Connection 3”, 4” & 5” All-Angle Connection 3”, 4” & 5” Bottom Connection Heavy-Duty Navy Thermometer Dual Mode Thermometer (DMT) OEM Thermometers Laboratory Thermometers Compost Thermometers Sanitary Bimetal Thermometer Bimetal Thermometer Accessories and Ranges Page 3 Page 4 Page 5 Page 6 Page 7 Page 8-9 Page 10 Page 11 Page 11 Page 12 Page 13 Thermowells Threaded Type (1/4” elements) (3/8” elements) Sanitary Type Flanged Type Page 14 Page 24 Page 14 Page 15 Filled System Thermometers 2 Industrial Glass Thermometer Vapor Actuated Remote Thermometers Page 16 Page 17-19 Gas Actuated Remote Thermometers Bourdon Tube Type Direct-Drive Type Page 21-24 Page 25-27 Digital Thermometers Page 28 RTD’s & Thermocouples Page 29-32 Sanitary RTD’s Page 33-34 Surface Thermometers Page 35 Pocket Thermometers Page 35 Warranty Back Page Established in 1965 and located in San Diego, California, R E G I S T E R E D REOTEMP Instrument Corporation is recognized as a leading manufacturer of pressure and temperature instrumentation. REOTEMP provides bimetal thermometers, pressure gauges, diaphragm seals and related accessories to a variety of process markets worldwide. Recognized for exceptional customer service, on-time deliveries and innovative engineering services, REOTEMP is an ISO 9002 certified manufacturer. We are dedicated to continuous improvement, on-time deliveries, high quality products, and exceptional customer satisfaction. Markets Served Oil, Gas & Petrochemical Pharmaceutical Food & Beverage Paper & Pulp Mining Utilities Marine Waste Water Compost Military Dairy Power Generation Refrigeration And More! Bimetal Thermometers Specifications R E G I S T E R E D Specifications – Bimetal Dial Thermometers Dial Sizes: 1 1/8”, 1 3/4” 2 3/8”, 3” 4” 5” Stem Length: Between 2” and 80” Stem Diameters: 1/4” (standard), also available 5/16”, 3/8”. Heads, bezels, mounting bushing, stems: All Models 300 series SS Operating Conditions: The temperature of the head should not be allowed to exceed 200° F (150° F if silicone filled). Stems should not be exposed to continuous temperatures exceeding 50% overrange, or 800° F. Hermetic seal: All 3”, 4”, and 5” models (except DM4) are hermetically sealed per ASME B40.3. Pointed Stems: Optional on all models. Excellent for probing asphalt, compost, soil, frozen foods or other semi-solid materials. Dials: Anodized aluminum. Black marks and numbers with satin matte finish background. Crystals: Optically clear strong glass. Optional: Unbreakable clear plastic: all models (Not recommended for ranges over 500° F). Optional: “Shatterproof” tempered glass (3”, 4”, and 5” models). Accuracy: All Models are guaranteed accurate to within plus or minus 1% of the full scale (Grade A per ASME B40.3). Temperature readings are stabilized within 40 seconds. Immersion: For correct temperature measurement, the stem of all Models in all ranges must be immersed 2 inches in liquid, and 4 inches in gas except for 0 to 100° F, 25 to 125° F, and 0 to 50° C which require 3 1/2 inches in liquid and 5 inches in gas. Mounting Connections: 1/2” NPT (std. on 3”, 4”, 5” models), 1/8” NPT, 1/4” NPT, 3/8” NPT, 3/4” NPT, 3/8”-24” NF, Plain or Reset Bushing, 1/2” NPT Union, 1/2” BSPT, BSPP Adapters. Thermowells Thermowells should be used whenever the stem or bulb would be exposed to pressure, corrosion, or shear forces. Thermowells also make it possible to remove the thermometer without losing pressure or contents. (See pages 14-15 for more details) O.E.M. Applications If you are an Original Equipment Manufacturer and plan to incorporate the REOTEMP Thermometer in your finished product for resale, special ranges or special dials can be made to suit your particular requirements. Such specials can bear your own company name and/or trademark on the dial. The quality, appearance, and performance of a REOTEMP Thermometer will complement and enhance your equipment. 3 Bimetal Thermometers Back Connected (Angle Form) Industrial 3”, 4”, 5” Dial REOTEMP Angle Form thermometers are ideal for local, eye-level temperature readings in most process applications. Standard Features • • • • • All Stainless Steel Construction Hermetically Sealed (ASME B40.3) Accurate to 1% of Full Scale Standard External Reset Silicone Fillable for Vibration How to Order AA Models 060 Stem Length Standard Models AA = Model A 025 = 2.5" 1 Connection Standard Threaded* 1 = 1/2" NPT (std.) (3" dial, reset) 040 = 4" 4 = 1/4" NPT 060 = 6" 5 = 3/4" NPT adapter 090 = 9" X = Plain Hex Bushing BB = Model B (5" dial, reset) CC = Model C (4" dial, reset) (no threads) 120 = 12" Non-Reset Models RR = Model R B = 1/2" BSPT 150 = 15" Sanitary* (3" dial, no reset) 180 = 18" C = 1-1/2" Tri-Clamp 240 = 24" L = 2" Tri-Clamp 300 = 30" M = 3/4" Tri-Clamp 360 = 36" For more information on Sanitary Thermometers see page 12 SS = Model S (5" dial, no reset) CN = Model CN (4" dial, no reset) -Intermediate lengths available up to 80” -Specify length in inches + tenths *-Other sizes available F43 Temperature Ranges See pg.13 for a full list. Fahrenheit Ranges -40 TO 160°F 25 TO 125°F 0 TO 200°F 0 TO 250°F 50 TO 300°F 50 TO 500°F 150 TO 750°F 200 TO 1000°F Celsius Ranges -40 TO 70°C C23 0 TO 50°C C55* 0 TO 100°C C43 -20 TO 120°C C47 0 TO 150°C C59 0 TO 250°C C67 0 TO 400°C C81 100 TO 500°C C85 Dual F/C Ranges D23 -40 TO 160°F & -40 TO 70°C D55* 25 TO 125°F & 0 TO 50°C 0 TO 100°C 0 TO 200°F & D43 0 TO 250°F & -20 TO 120°C D47 10 TO 150°C 50 TO 300°F & D63 0 TO 250°C 50 TO 500°F & D67 0 TO 400°C 150 TO 750°F & D81 200 TO 1000°F & 100 TO 500°C D85 F23 F55* F43 F47 F63 F67 F81 F85 SF Options PS = Pointed Stem SF = Silicone Fill (max temp 550°F) SS = 316 SS Stem F3 = 3/8" dia. Stem PC = Acrylic Window PY = Polycarbonate Window TG = Tempered Glass Window MM = Max/Min Pointer For Thermowells see pg. 14 *-Not available in 2.5" stem. REOTEMP INSTRUMENT CORPORATION Telephone: (800) 648-7737 FAX (858) 784-0720 · [email protected] · www.reotemp.com 4 Bimetal Thermometers Adjustable Angle Industrial 3”, 4”, 5” Dial R E G I S T E R E D REOTEMP All-Angle thermometer allows for easy temperature monitoring from any position. Standard Features • • • • • • • Complete 180° Adjustability All Stainless Steel Construction Hermetically Sealed (ASME B40.3) Accurate to 1% of Full Scale Standard External Reset Silicone Fillable for Vibration 360° Case Rotation How to Order LL Models Standard Models LL = Model L (3" dial, reset) 060 Stem Length 1 Connection 025 = 2.5" Standard Threaded 1 = 1/2" NPT (std.) 040 = 4" 5 = 3/4" NPT adapter 060 = 6" U = 1/2" NPT Union 090 = 9" Sanitary* C = 1-1/2" Tri-Clamp MM = Model M (4" dial, reset) JJ = Model J (5" dial, reset) 120 = 12" L = 2" Tri-Clamp 150 = 15" M = 3/4" Tri-Clamp 180 = 18" 240 = 24" 300 = 30" 360 = 36" For more information on Sanitary Thermometers see page 12 -Intermediate lengths available up to 80” -Specify length in inches + tenths *-Other sizes available F43 Temperature Ranges See pg.13 for a full list. Fahrenheit Ranges -40 TO 160°F F23 25 TO 125°F F55* 0 TO 200°F F43 0 TO 250°F F47 50 TO 300°F F63 50 TO 500°F F67 150 TO 750°F F81 200 TO 1000°F F85 Celsius Ranges -40 TO 70°C C23 0 TO 50°C C55* 0 TO 100°C C43 -20 TO 120°C C47 0 TO 150°C C59 0 TO 250°C C67 0 TO 400°C C81 100 TO 500°C C85 Dual F/C Ranges -40 TO 160°F & -40 TO 70°C D23 0 TO 50°C D55* 25 TO 125°F & 0 TO 100°C 0 TO 200°F & D43 0 TO 250°F -20 TO 120°C & D47 10 TO 150°C 50 TO 300°F & D63 0 TO 250°C 50 TO 500°F & D67 0 TO 400°C D81 150 TO 750°F & D85 200 TO 1000°F& 100 TO 500°C SF Options PS = Pointed Stem SF = Silicone Fill (max temp 550°F) SS = 316 SS Stem F3 = 3/8" dia. Stem PC = Acrylic Window PY = Polycarbonate Window TG = Tempered Glass Window MM = Max/Min Pointer For Thermowells see pg. 14 *-Not available in 2.5" stem. 5 Bimetal Thermometers Bottom Connected (Straight Form) Industrial 3”, 4”, 5” Dial .75 Reset 3" dia (Model XR) 4" dia (Model Y) 5" dia (Model VR) REOTEMP Straight Form R E G I S T E R E D thermometers are ideal for side and elevated installations on tops or sides of tanks or pipes. Standard Features • Bottom, Top, Right or Left Side Mounting • All Stainless Steel Construction • Hermetically Sealed (ASME B40.3) • Accurate to 1% of Full Scale • Standard External Reset • Silicone Fillable for Vibration .62 Stem Length 1/4" dia (Standard) How to Order XR 060 Models Stem Length Standard Models XR = Model XR 1 Connection 025 = 2.5" Standard Threaded* 1 = 1/2" NPT (std.) 040 = 4" 4 = 1/4" NPT 060 = 6" 5 = 3/4" NPT adapter 090 = 9" Sanitary* C = 1-1/2" Tri-Clamp (3" dial, reset) YY = Model Y (4" dial, reset) VR = Model VR (5" dial, reset) 120 = 12" Non-Reset Models XX = Model X L = 2" Tri-Clamp 150 = 15" (3" dial, no reset) M = 3/4" Tri-Clamp 180 = 18" YN = Model YN (4" dial, no reset) VV = Model V 240 = 24" 300 = 30" For more information on Sanitary Thermometers see page 12 (5" dial, no reset) 360 = 36" -Intermediate lengths available up to 80” -Specify length in inches + tenths *-Other sizes available F43 Temperature Ranges See pg.13 for a full list. Fahrenheit Ranges -40 TO 160°F 25 TO 125°F 0 TO 200°F 0 TO 250°F 50 TO 300°F 50 TO 500°F 150 TO 750°F 200 TO 1000°F Celsius Ranges -40 TO 70°C C23 0 TO 50°C C55* 0 TO 100°C C43 -20 TO 120°C C47 0 TO 150°C C59 0 TO 250°C C67 0 TO 400°C C81 100 TO 500°C C85 Dual F/C Ranges D23 -40 TO 160°F & -40 TO 70°C 0 TO 50°C & D55* 25 TO 125°F 0 TO 100°C 0 TO 200°F & D43 0 TO 250°F & -20 TO 120°C D47 50 TO 300°F & 10 TO 150°C D63 0 TO 250°C 50 TO 500°F & D67 0 TO 400°C D81 150 TO 750°F & D85 200 TO 1000°F & 100 TO 500°C F23 F55* F43 F47 F63 F67 F81 F85 *-Not available in 2.5" stem. SF Options PS = Pointed Stem SF = Silicone Fill (max temp 550°F) SS = 316 SS Stem F3 = 3/8" dia. Stem PC = Acrylic Window PY = Polycarbonate Window TG = Tempered Glass Window MM = Max/Min Pointer 99 = 9 O'Clock Stem (left side) 33 = 3 O'Clock Stem (right side) 12 = 12 O'Clock Stem (top mount) REOTEMP INSTRUMENT CORPORATION Telephone: (800) 648-7737 FAX (858) 784-0720 · [email protected] · www.reotemp.com 6 Bimetal Thermometers Heavy-Duty “Navy” Type Heavy-Duty Navy Type Standard Features • • • • • • • • Back (Angle) Form 3” Dial – Bimetal Actuation Heavy Duty – Vibration and Shock Resistant Stainless Steel – Sealed Construction Plastic Crystal External Reset is Standard 1% Accuracy Fits in 5” Scale “Submarine” Thermometer Well 3/4” – 28 UN2A Union Connection – (to be used in thermowell) How to Order 1. Model 2. Range M odels Straight Form Ran ges B ack Angle Form AN2= 2” AN4= 4” AN6= 6” Straight Form XN2= 2” XN4= 4” XN6= 6” F23 F25 F43 F53 F63 F65 F69 F73 N ote: m inim um im m ersion length is 2” C13 C53 C59 C65 C69 Fahrenheit R ang es -40 TO 120° F in 2° divs.* -40 TO 180° F in 2° divs. 0 T O 200° F in 2° divs. 20 T O 240° F in 2° divs. 50 T O 300° F in 2° divs. 50 T O 400° F in 5° divs. 50 T O 550° F in 5° divs. 50 T O 750° F in 10° divs. C elsius R anges -50 TO 50° C in 1° divs.* -10 TO 110° C in 1° divs. 0 T O 150° C in 2° divs. 0 T O 200° C in 2° divs. 0 T O 300° C in 5° divs. *-4" M inim um stem length (on straight, left, or right side form s only) Thermometer Wells Well Class Class A (3/4" NPT) Class W (Socket Weld) Thermometer Well Length Model No. Stem Length (overall) Brass 304 SS 316 SS 2" 4" 6" 2" 4" 6" 3 1/4" 5 1/4" 7 1/4" 3 5/16" 5 5/16" 7 5/16" STN2B STN4B STN6B STN2S STN2SS STN4S STN4SS STN6S STN6SS SWN2SS SWN4SS SWN6SS A & W Wells 1" 2 3" 4 STEM LENGTH 1 "DIA. 2 1 5/16" STEM LENGTH 1.05" DIA. Bimetal Thermometers Silicone-Filled Thermometers REOTEMP Silicone-filled thermometers are offered for severe industrial applications, where vibration is a problem. Silicone dampening prolongs instrument life by preventing wear and fatigue in the instrument’s internal parts. The silicone also improves readability by reducing pointer flutter, and promotes faster temperature response. Any REOTEMP 3”, 4” or 5” dial bimetal thermometer (except Model DM4) can be silicone filled, in any stem length, and any temperature range up to 550° F. (Silicone filling with ranges over 550° F not recommended.) All silicone-filled thermometers come with a durable polycarbonate crystal. How to Order Specify option “SF” at the end of any 3”, 4” or 5” dial bimetal thermometer. (e.g., Model AA-040-1-F47-SF). See pg. 4-6 7 Bimetal Thermometers Dual-Mode Thermometer R E G I S T E R E D REOTEMP DUAL MODE THERMOMETER (model DMT) is a convenient, multipurpose indicator for local and remote temperature monitoring. This rugged dual-sensor system puts TWO SENSORS in ONE THERMOWELL, and allows easy tie-in to process control. Both sensors are NIST traceable, and easily calibrated. Special sensor encapsulation and optional liquid filling make the DMT the most rugged, durable instrument of its kind. Bimetal Thermometer • Local easy-to-read Temperature Indication • Self-actuating, Dampened Bimetal Helix • Choice of three Dial Sizes, with Back, Bottom, or Adjustable Angle Connection • Hermetically Sealed per ASME B40.3 • Thermometer is Easily Calibrated, and Field Replaceable • NIST Traceable Calibration Thermocouple or RTD • Remote and Local Indication • Data Acquisition for Process Control • Choice of Connection Styles (see drawing below) • 4-20mA Transmitter Output Available Model DMT with Screw Cover Terminal Head, and AdjustableAngle Head DMT Advantages: • Allows local and remote reading (Up to 1000°F) from one thermowell. • Bimetal dependability with RTD (or thermocouple) accuracy. • Redundant sensors for simple, effective calibration or spot checking without removing instrument from thermowell! • Easily installed in any standard thermowell. • Interchangeable with existing thermometer, RTD, Thermocouple. with optional T/C Transmitter (HT) or with optiona RTD Transmitter (HR) REOTEMP INSTRUMENT CORPORATION 8 Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com Bimetal Thermometers Dual-Mode Thermometer How to Order Model Style/Stem Stem Length Temp Range Sensor (Table 1) (Table 3) (Table 2) (Table 4) Output Connection Thermowell (Table 6) (Table 5) DM TA 04 F24 TK MC 046 Table 1 - Style & Stem Dia. Code Description 3/8" Stem 1/4" Stem TA TC TB TL TM TJ 4A 4C 4B 4L 4M 4J Table 6 - Thermowell (.385” & .260” bore) Process Stem "U" 3/8 Stem 1/4" Stem Connection Length Dim 304 SS 316 SS 304 SS 316 SS 3" 4" 5" 3" 4" 5" Back Connected Back Connected Back Connected Adjustable-Angle Adjustable-Angle Adjustable-Angle 1/2" NPT 3/4" NPT Table 2 - Stem Length Code Length Code Length 02* 04 06 09 12 2.5" 4" 6" 9" 12" 15 18 24 30 36 Table 3-Temperature Range Code * min. stem length 4” Degrees F & C D03 -100 TO 100°F & -70 TO 70°C D23 140 TO 160°F & -40 TO 70°C D55 25 TO 125°F & 0 TO 50°C D43 0 TO 200°F & 0 TO 100°C D47 0 TO 250°F & -20 TO 120°C D53 20 TO 240°F & -10 TO 115°C D63 50 TO 300°F & 10 TO 150°C D65 50 TO 400°F & 10 TO 200°C D69 50 TO 550°F & 10 TO 290°C D79 100 TO 800°F & 40 TO 400°C D85** 200 TO 1000°F&100 TO 500°C **continuous use over 800F not recommended. DMT Specifications Case and Bezel: Case Style: Dial Size: Process Connection: External Reset: Crystal: 071 072 073 074 046 047 048 049 053 054 055 056 171 172 173 174 146 147 148 149 153 154 155 156 011 012 013 014 018 019 020 021 025 026 027 028 111 112 113 114 118 119 120 121 125 126 127 128 304 SS (316 SS Available) Back, Bottom or Adjustable Angle connection. 3”, 4” or 5” 1/2” NPT Standard, (1/2” NPT Union available) Slotted Hex Screw Glass Standard, Plastic or Tempered Glass optional Hermetic Seal: Bi-Metal Thermometer per ASME B40.3 Stem: 304 SS, 0.375” O.D. (1/4” O.D. - specify “DMT4”) Lengths from 2-1/2” to 36” RTD-T/C Encapsulation Sleeve (Pat.pending): 304 SS RTD: 100Ω (or 1000Ω optional) Platinum; 0.00385Ω/Ω/°C, 3-wire std. Thermocouple: Type K grounded junction std. (Optional: types T, E, J, or ungrounded.) Description MP Mini - Plug Receptacle (Thermocouple Only) MC Mini - Connection Head, w/screw terminals & protection head EC 1/2" NPT Male Electrical Connection, w/Lead Wire * available only with 3/8” dia. stem. C03 -70 TO 70°C C23 -40 TO 70°C C55* 0 TO 50°C 0 TO 100°C C43 C47 -20 TO 120°C C53 -10 TO 110°C 0 TO 150°C C59 0 TO 200°C C65 0 TO 300°C C69 C79 50 TO 400°C C85** 100 TO 500°C 2.5 4.5 7.5 10.5 2.5 4.5 7.5 10.5 2.5 4.5 7.5 10.5 Table 5 - Output Connection Code Degrees F Code Degrees C Code F03 -100 TO 100°F F23 40 TO 160°F F55* 25 TO 125°F F43 0 TO 200°F F47 0 TO 250°F F53 20 TO 240°F F63 50 TO 300°F F65 50 TO 400°F F69 50 TO 550°F F79 100 TO 800°F F85** 200 TO 1000°F 1" NPT 15" 18" 24" 30" 36" 4" 6" 9" 12" 4" 6" 9" 12" 4" 6" 9" 12" Aluminum screw - Cover Head w/3/4" NPT Conduit Connection HA with Terminal Block HT with 4-20 mA Transmitter (for Thermocouple) HR with 4-20 mA Transmitter (for RTD) Table 4 - Sensor Code Description TK TJ TE TT UK UJ UE UT RC RK Thermocouple, Type K (grounded) Thermocouple, Type J (grounded) Thermocouple, Type E (grounded) Thermocouple, Type T (grounded) Thermocouple, Type K (ungrounded) Thermocouple, Type J (ungrounded) Thermocouple, Type E (ungrounded) Thermocouple, Type T (ungrounded) RTD, 100 ohm, 3-wire max. 550°F RTD, 1000 ohm, 3-wire } Connection: T/C plug, Mini connection head, or Standard screw-cover connection head are available, Special customer requirements accommodated. Ranges: Std. REOTEMP ranges and divisions to 1000F (500C) Over Ranges: 50% over range to 550F, 1000F max. Accuracy: (+/-) 1% of full scale Thermowell: Model DMT fits any standard 0.385” bore thermowell. (See table for Std. Models). Options: Silicone Case Fill for Vibration. (3/8” stem only) NOTE: Model DMT is intended for use ONLY in a thermowell. 3-A and NACE conformity available. 9 Bimetal Thermometers R E G I S T E R E D OEM Dial Bimetal Thermometers REOTEMP OEM Thermometers (Models Q, G, and H) are the perfect choice for equipment with limited space and requiring a rugged, dependable and economical temperature sensor. Available with a wide variety of mounting threads. Model H - 2 3/8” Dial Model G - 1 11/16” Dial Model Q - 1 5/32” Dial .24 .17 .24 .24 .17 .33 dia .33 dia 1/4" dia 1.16 dia 2.37 dia 1.70 dia Stem Length Stem Length Stem Length .29 1/4" dia 1/4” Dia. 1/4" dia .30 .36 Mounting Thread Options 1/2” NPT 3/8” NPT 1/4” NPT 3/8-24 UNF 9/16” HEX BUSHING 1/8” NPT How to Order QQ Models 025 Stem Length 2 Connection OEM Models 025 = 2.5" 2 = Plain Bushing (std.) 040 = 4" 1 = 1/2" NPT (1-3/4" dial) 060 = 6" 3 = 3/8-24 NF HH = Model H (2-3/8" dial) 090 = 9" QQ = Model Q (1-1/4" dial) GG = Model G (straight threaded) 4 = 1/4" NPT 120 = 12" Lab & Test Models QP = Model QP (1-1/4" dial) 5" Stem 6 = 1/8" NPT 150 = 15" 7 = 3/8" NPT 180 = 18" 8 = Hex Reset Bushing GL = Model GL (1-3/4" dial) 8" Stem HL = Model HL (2-3/8" dial) 8" Stem 240 = 24" 300 = 30" 360 = 36" -Intermediate lengths available up to 80" -specify length in inches + tenths *-Other sizes available F43 Temperature Ranges (See pg 13 for full list) Fahrenheit Ranges -40 TO 160°F 25 TO 125°F 0 TO 200°F 0 TO 250°F 0 TO 300°F 50 TO 500°F 150 TO 750°F 200 TO 1000°F Celsius Ranges -40 TO 70°C C23 0 TO 50°C C55* C43 0 TO 100°C C47 -20 TO 120°C C63 0 TO 150°C C67 0 TO 250°C C81 0 TO 400°C C85 100 TO 500°C Dual F/C Ranges -40 TO 160°F & -40 TO 70°C D23 25 TO 125°F & 0 TO 50°C D55* 0 TO 200°F & 0 TO 100°C D43 D47 0 TO 250°F & -20 TO 120°C D63 0 TO 300°F & 0 TO 150°C D67 50 TO 500°F & 0 TO 250°C D81 150 TO 750°F & 0 TO 400°C 200 TO 1000°F & 100 TO 500°C D85 F23 F55* F43 F47 F63 F67 F81 F85 PS Options PS = Pointed Stem SS = 316 SS Stem PC = Plastic Window PB = Plain Bushing (non-reset)* *for lab and test Models only *-Not available in model Q. REOTEMP INSTRUMENT CORPORATION Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com 10 Bimetal Thermometers Hand-held Laboratory Thermometers REOTEMP Laboratory Thermometers (QP, GL & HL) are ideal for testing and spot checking local temperatures in a variety of critical process or lab applications. Pointed stems are available for insertion in semi-solids such as soil, meat, etc. Model QP - 1 5/32” Dial Model GL - 1 11/16” Dial (with point - Model QPP) Model HL - 2 3/8” Dial (with point - Model GLP) (with point - Model HLP) .24 .24 .24 9/16" Hex Re-set Bushing 1/4" dia 1.16" dia 9/16" Hex Re-set Bushing 9/16" HEX RE-SET BUSHING 1/4" dia 2.37" dia 1.70" dia 6" Stem 1/4" dia 8" Stem 8" Stem .30 .30 .36 How to Order Specify Model and Range (see table, pg. 10), Example: QP - F43 Bimetal Thermometers Compost Thermometers Applications For Composting Food and Yard Waste Ideally suited for monitoring interior temperature of compost bins or windrows. Used By: Waste Treatment Plants. City, State and Federal Recycling Programs. Farms and University Compost Programs. Compost Chicken, Hog and Fish wastes. Mushroom Farms. Standard Model: A36 PF (36” Pointed Stem, 0/200° F) Also Backyard Compost Thermometer: G20P (2” Dial, 20” Stem, 0/200° F) Standard Features Hermetically sealed — will not fog Pointed stem for easy insertion Rugged, all stainless construction Heavy duty 5/16” diameter stem Easy to read 3” diameter dial Unbreakable plastic crystal °F & °C scales available (Std. range, 0 - 200°F) • Accuracy +/- 1% of scale • Stem lengths up to 72” available • • • • • • • 11 Sanitary Bimetal Thermometers Sani-Temp REOTEMP SANI-TEMP Bimetal Thermometer is specially designed for direct insertion into sanitary process applications when a standard thermowell is not specified or the process environment is not exposed to pressure. The SANI-TEMP provides a quick temperature response and will mate with existing process connections. The SANI-TEMP is ideal for the food, beverage and pharmaceutical industries. “C” Dia. • • • • • • Quick connect Tri-clamp design Fast installation and removal Hermetically sealed case Ideal for CIP and SIP Designed to meet 3A Sanitary standards External Reset Specifications Sanitary Flange "C" see chart 1 " dia 4 Thermometer Head Stem Length Customer Specified How HowtotoOrder Order Flange Type Sanitary Flange Sizes Specify Sanitary Connection. 3” 4” 5” 316/316L polished stainless 300 series polished st. stl. Tri-clamp (standard), Cherry-Burrell (optional) Windows: Glass- (standard) see option table Optional: Acrylic, Polycarbonate, or Tempered Glass Silicone Filling available for Vibration Bimetal Models Stem Lengths Temperature Range (See pg. 13 for a full list.) Back Connected Use “How to Order” Codes on pg. 4, 5, 6. Dial Size: Wetted Parts: Case & Ring: Process Connection: Tri-Clamp (standard) M = 3/4" C = 1" or 1 1/2" A = 3" C = 4" B = 5" 2 1/2" 4" See pg. 4 L = 2" A = 2 1/2" T = 3" Bottom Connected XR = 3" Y = 4" VR = 5" 6" 9" Other Types Available See pg. 5 Celsius F23 -40 TO 160°F F55* 25 TO 125°F F43 0 TO 200°F F47 0 TO 250°F F63 20 TO 240°F F67 F81 50 TO 300°F F85 50 TO 400°F C23 -40 TO 70°C C55* 0 TO 50°C C43 0 TO 100°C C47 -20 TO 120°C C63 -10 TO 110°C C67 C81 0 TO 150°C C85 0 TO 200°C 12" See pg. 6 Adjustable Angle L = 3" M = 4" J = 5" Farenheit 15" Other Stems Available D23 D55* D43 D47 D63 D67 D81 D85 Dual F/C Ranges -40 TO 160°F -40 TO 70°C & & 25 TO 125°F -5 TO 50°C & 0 TO 200°F -10 TO 90°C & 0 TO 250°F -20 TO 120°C & 20 TO 240°F -10 TO 115°C & 50 TO 350°F 10 TO 150°C & 50 TO 400°F 10 TO 200°C & REOTEMP INSTRUMENT CORPORATION Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com 12 Sanitary Bimetal Thermometers Temperature Ranges R E G I S T E R E D Bimetal Temperature Range Master List - (Other ranges available on application. Y = available) Code F03 F07 F11 F21 F23 F Ranges Div Q G H 3,4,5** -100/100F 2 Y Y Y -80/120F 2 Y Y -70/150F 2 Y -40/120F 2 Y -40/160F 2 Y Y Y Y F19 F31 F35 F55 F37 F39 F43 F45 F47 F53 F63 F65 F67 F69 F79 F81 F85 -50/300F 2 Y -20/120F 2 Y 0/100F* 1 25/125F* 1 Y Y 0/140F 2 0/150F 1 0/200F 2 Y Y 0/220F 2 Y 0/250F 2 Y Y 20/240F 2 Y 50/300F 2 Y Y 50/400F 5 50/500F 5 Y Y 50/550F 5 100/800F 10 Y 150/750F 10 Y Y 200/1000F 10 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y * = Minimum stem 4" ** Includes all 3", 4", and 5" models (back, bottom, or all-angle) Code C03 C07 C11 C23 C Ranges -70/70C -50/50C -50/100C C19 C31 -40/70C -50/200C -40/160C -20/40C* C55 C37 0/50C* 0/60C* C43 0/100C C47 C53 C63 C65 C67 C69 C79 C81 C85 -20/120C -10/110C 0/150C 0/200C 0/250C 0/300C 0/400C 50/400C 100/500C DivQ G H 3,4,5** Y 1 Y Y Y 2 Y Y Y Code Dual Ranges D03 -100/100F & -70/40C Q G H 3,4,5** Y Y Y D11 -50/210F & -50/100C Y Y Y Y D23 -40/160F & -40/70C Y Y Y Y 1 Y Y Y Y D55 D37 D39 D43 25/125F 0/140F 0/150F 0/200F & & & & -5/50C* -15/60C -20/70C -10/90C 2 1 1 2 2 2 5 5 5 Y Y Y Y Y Y Y D47 D53 D63 D65 D67 D69 0/250F 20/240F 50/300F 50/400F 50/500F 50/550F & & & & & & -20/120C -10/115C 10/150C 10/200C 10/260C Y 10/290C 1 Y Y Y 2 2 1 1/2 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y D81 150/750F & 70/400C D85 200/1000F & 100/500C Y Y Y Y Y Y Y Y Y Y Y Y Y Bimetal Thermometers Accessories Accessories AS-86 Adapter Kit: permits installation of bimetal thermometer in existing mercury-in glass-industrial thermometer thermowell. HT Heat Transfer Compound (2 oz, 1 lb containers) D3 Duct Flange (1/2" NPT) CH T-27 spring handle CP Pan Clip Calibration CC Certificate of Conformance C1 1 Point Calibration Certificate C3 3 Point Calibration Certificate Options Code MM MA TG PC SF SD GF PS 3H SS F5 S3 F3 TF MB TS TP NL BQ Description Minimum or Maximum resettable pointer (one hand) Minimum and Maximum resettable pointer (two hands) Tempered Glass Lens Plastic Lens Silicone Filled Silicone Filled, food grade Glycerine Filled Pointed Stem 316SS Head and Bezel 316SS Stem 5/16” diameter stem 3/8” diameter stem 3/8” diameter aluminum sleeve Teflon Coating (stem only) External Mounting Brackets Stainless Steel Tags Paper Tags No Logo Dial BBQ Dial Model 3”, 5” 3”, 5” 3”, 4”, 5” All 3”, 4”, 5” 3”, 4”, 5” 3”, 4”, 5” All 3”, 4”, 5” All 3”, 4”, 5” 3”, 4”, 5” 3”, 4”, 5” All G, H All All All 3” Also available on request – Custom dials, special ranges, special configurations. 13 Thermowells Threaded, for Bimetal Thermometers R E G I S T E R E D Thermowells make it possible to remove instruments without dropping pressure or losing contents. Each stainless Thermowell die stamped with type of material from which it is made. Type ST How to Order 1. 2. 3. 4. Type LG “T” Lag Extension Type: Thermometer Stem Length: Material: ST External Thread: M odels Stem "A" Dim 2 1/2" 4" 6" ST 9" 12" 15" 18" "A" Dim 6" 9" LG 12" (lagging) 15" 18" 24" "U" Dim 1 5/8" 2 1/2" 4 1/2" 7 1/2" 10 1/2" 13 1/2" 16 1/2" "U" Dim "T" Dim 2 1/2" 2" 4 1/2" 3" 7 1/2" 3" 10 1/2" 3" 13 1/2" 3" 19 1/2" 3" Example: 4” M aterial 304 SS 304 SS External Thread 3/4” Options 3/4" NPT Socket-W eld W ell (Standard) 316 SS Brass Optional: 1/2" NPT Tapered Straight Carbon Steel 1" NPT Santary Tri-Clamp .385 Bore (for 3/8" elements) Sanitary Thermowells Features Provides Sanitary Protection for Temperature Probes All 316L Stainless Steel Construction Fast Installation & Removal Ideal for Food, Beverage, Biotech & Pharmaceutical Applications • Finish Exceeds Ra 32 max. • Exceeds 3A #4 Finish • • • • How to Order Specify Part Number: Tri-Clamp "A" Stem Size Lengths 1 1/2" 1/2” MAX O.D. 2" 2 1/2" .260 BORE 3" 2 1/2" 4" 6" 9" 2 1/2" 4" 6" 9" 2 1/2" 4" 6" 9" 2 1/2" 4" 6" 9" Part No. "U" Dim STF-1.5-2.5 STF1.5-4 STF1.5-6 STF1.5-9 STF2-2.5 STF2-4 STF2-6 STF2-9 STF2.5-2.5 STF2.5-4 STF2.5-6 STF2.5-9 STF3-2.5 STF3-4 STF3-6 STF3-9 1 2 4 7 1 2 4 7 1 2 4 7 1 2 4 7 5/8" 1/2" 1/2" 1/2" 5/8" 1/2" 1/2" 1/2" 5/8" 1/2" 1/2" 1/2" 5/8" 1/2" 1/2" 1/2" REOTEMP INSTRUMENT CORPORATION Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com 14 "C" Dim (Flange Dia.) 2 (51mm) 2.5 (63mm) 3.6 (76mm) 4.7 (91mm) Thermowells R E G I S T E R E D TYPES Flanged Well 2-1/4 Standard Threaded Wells U INSERTION LENGTH 1/4" 1/4" BORE A (.75) 1-1/4" dia 1.0 BORE DIA Q Q (.50) 1/2" NPT FLANGE SIZE & RATING CUSTOMER SPECIFIED P U A ELEMENT LENGTH Socket-Weld Well Sanitary Well A U 1/8" 1-3/4" 3/8" DIA 1/4" Q2 C BORE SIZE Q1 P 1/4" 1/2" NPT 1/2" NPT (.250 DIA) U Standard Stepped Shank A SHANK STYLES Tapered Shank Q1 Q1 Q2 Q2 Straight Shank Q How to Order Type Material Shank Style or (U-dim) Order By Specifying: 1. Type and Bore Dia. 2. Thermometer Stem “A” Length or “U” dimension. 3. Material. 4. Shank Style. 5. For Flanged Wells: -Flange Size and Rating. 6. For Threaded Wells: -Process Thread (P). 7. For Socket-Weld Wells: -Nominal Pipe Size. Element Length Externally Threaded (Standard Bimetal Type) Flanged Socket Weld Sanitary Type See Table pg. 14 304 SS 316 SS Carbon Steel Brass 316L SS Monel Hastelloy B Hastelloy C Titanium Tantalum Teflon Stepped Straight Tapered Flange Wells Socket-Weld Wells Flange Size and Rating Pipe Size Nom. Example: 1 1/2", 150# Example: 3/4" Pipe Call Factory for help specifying well, if needed 15 Liquid-In-Glass Thermometer All Angle Industrial Specifications: Case: Modern V-shape design with parts molded of GE Valox® polyester, in black textured finish. Heavy glass protected front firmly secured by spring action. Stem: Tapered bulb chambers are made of precision ground aluminum. The tapered chamber forms a metal contact with matching taper in the sockets assuring maximum speed of response to temperature changes. Graphite is used as a conducting media between bulb chamber and glass tube. Locking Device: Adjustable case locknut and angle adjusting screw work independently to provide full 360° positioning of thermometer case and stem. Tube & Capillary: Mercury filled-magnifying lens “Red Reading” tube (Spirit Filled option available). Precision made to guarantee accuracy within 1% of scale range. Silicone shock mounting for lasting durability. When Mercury is not desired, alcohol-based spirit fill is available Scale: 9" scale with white coated aluminum and permanently baked bold black markings. Applications: REOTEMP “All Angle” Industrial Thermometers are used in pipelines of all types, commercial building application (heating & cooling), process piping, tanks, boilers, etc. How to Order 9VX35 016 SOC35B RETORT THERMOMETERS For Rubber Vulcanizers, Retorts, Coolers, Kettles. 9” Scale Straight or Angle Form, 3 ½” 304 SS Stem, with ¾ NPT 304 S.S. Hub. INDUSTRIAL THERMOMETERS 9” Scale, All Angle with 1 1/4”-18” Swivel Nut Stem 3 ½" 6" 9" 1. Part # 2. Range Code 3. Accessories Part # Mercury Filled Spirit Filled 9VX35 9VS35 9VX06 9VS06 9VX09 9VS09 Shaded items normally in stock. STANDARD Code Range Divisions 411 118 212 012 016 318 324 330 -40 TO 110°F -10 TO 180°F -20 TO 120°F 0 TO 120°F 0 TO 160°F 30 TO 180°F 30 TO 240°F 30 TO 300°F 2° 2° 2° 1° 2° 2° 2° 2° Range Form Part # 170/270°F & 0/30psi 170/270°F & 0/30psi 80/130°C & 0/2 kg/cm2 80/130°C & 0/2 kg/cm2 200/400°F & 0/200psi 200/400°F & 0/200psi Angle Straight Angle Straight Angle Straight 9RA35F 9RS35F 9RA35C 9RS35C 9RA35FV 9RS35FV Separable Sockets Extension Stem Insertion ¾” NPT External Length Length Neck Length Brass 304 SS 3 ½" 6" 9" 2 ½" 5" 8" - SOC35B SOC35S SOC06B SOC06S SOC09B SOC09S 6" 2 ½" 2 ½" SEN06B SEN06S 5 ½" 2 ½" ¾ NPT External Thread SEN09B SEN09S U A U 1" T A Union Hubs 9" UH3B REOTEMP INSTRUMENT CORPORATION Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com 16 UH3S Filled System Thermometers Vapor Actuated R E G I S T E R E D REOTEMP remote Vapor actuated Thermometers are manufactured to the highest standards for a wide range of uses and may be fitted into almost any temperature indicating application. These instruments are ideal for remote reading, such as panel installations, with capillary lengths of 1 to 100 feet. Being vapor actuated, they are not subject to indicator error due to ambient temperature variations along the capillary tube system, and will give excellent readings provided the temperature being measured is above or below ambient temperature. Vapor instruments have progressive graduations, and are best read in the upper 2/3 of the dial range. Many ranges are available between –40°F and +450°F, and care should be exercised to select a range that will locate the operating temperatures within the upper 2/3 of the dial range (see ranges on back page). Specifications: Dial Sizes: 2", 2 ½”, 3 ½”, 4 ½” Window: Polycarbonate, or Glass. Dial: Aluminum with white finish and black markings, other colors available. Bulb: Stainless Steel or copper. Bulb O.D. 7/16" (threaded), 3/8" (plain). Bulb lengths vary from 2 ½” to 9 ¼” depending on capillary length. Pointer: Standard adjustable. Accuracy: Plus or minus one scale division. Capillary: Copper, copper with bronze braid armor, stainless steel, stainless steel with stainless steel armor. Capillary lengths 1 to 100 feet (standard length 5 feet). Case: All stainless steel, except: VA45FL (Aluminum) VA45TB (Phenolic). Ranges: Over twenty °F and °F/°C ranges available, from –40° to + 450°F (see illustration, back page). Process Connection: Plain Bulb, 1/2" NPT Union, ½” NPT sliding union on 12" bendable extension, or Thermowell. NOTE: Thermowells must be used whenever the bulb would be exposed to pressure, fluid velocity, or corrosive media Applications: Control panels, chemical processing, pipelines, food processing, OEM applications, ovens, Movement: Brass with precision gearing. Bourdon Tube: Phosphor bronze. solar heating, refrigeration, etc. 17 Filled System Thermometers Vapor Actuated - How to Order Model V Vapor Actuated Case Style & Size (Table 1) Temperature Range (Table 2) Capillary & Bulb (Table 3) V 20FR 21 D Capillary Length (in Ft.) (Table 4) Process Connection (Table 5) 05 L2 Table 1 - Case Style Front Flanged (Panel Mount) Code Dial Case Lens Connection Location SS SS SS SS Polycarbonate* Polycarbonate* Polycarbonate* Polycarbonate* Rear Rear Rear Rear Black Aluminum (hinge ring type) Glass Rear Code Dial Case Lens Connection Location 2" 20UR 25UR 2 1/2" 35UR 3 1/2" SS SS SS Polycarbonate* Polycarbonate* Polycarbonate* Rear Rear Rear Case Lens Connection Location SS SS SS SS SS Phenolic Polycarbonate* Polycarbonate* Polycarbonate* Polycarbonate* Polycarbonate* Glass** Rear Rear Bottom Rear Bottom Bottom (Turrent Mount) 20FR 25FR 35FR 45FR 2" 2 1/2" 3 1/2" 4 1/2" 45FL 4 1/2" U-Clamp (Panel Mount) Rear Flanged (Panel Mount) Code Dial 20RR 35RR 35RB 45RR 45RB 45TB 2" 3 1/2" 3 1/2" 4 1/2" 4 1/2" 4 1/2" Other Case Styles *Glass lens available, specify “Glass Lens” **Polycarbonate, lens available, specify “Poly Lens” Code Dial Case Lens Connection Location* 35SB 3 1/2" 45SB 4 1/2" SS Polycarbonate SS Polycarbonate Adjustable Bracket Mount 35DA 3 1/2" 45DA 4 1/2" SS Polycarbonate SS Polycarbonate "Direct" adj. Mount w/3.4 Cu bulb, 1/2" NPT* *Specify Model & Range Only. Example: V45DA-80 REOTEMP INSTRUMENT CORPORATION Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com 18 Filled SystemThermometers Vapor Actuated - How to Order R E G I S T E R E D *Ranges over 300° come with 316SS Capillary only. Table 2 -- Temperature Ranges °F and °C Ranges Code °F Ranges Code 20 30 32 72 49 80 50 56 60 68* 70* -40 TO 60°F -40 TO 110°F -20 TO 120°F 0 TO 180°F 0 TO 150°F 20 TO 220°F 40 TO 240°F 0 TO 250°F 30 TO 300°F 100 TO 350°F 200 TO 450°F K2 L2 M2 -40 TO 60°F -40 TO 110°F -20 TO 120°F 0 TO 180°F 0 TO 150°F 20 TO 220°F 40 TO 240°F 0 TO 250°F 30 TO 300°F 100 TO 350°F 200 TO 450°F 21 31 33 73 79 81 51 57 61* 66* 71* Table 5 -- Code J1 Process J2 Connection J3 Table 3 -- Capillary & Bulbs Capillary & Capillary Bulb Material Protection Code & -40 TO 15°C & -40 TO 40°C & -30 TO 50°C & -20 TO 80°C & -15 TO 65°C & 0 TO 105°C & 0 TO 115°C & & -20 TO 120°C & 0 TO 150°C & 40 TO 175°C & 100 TO 230°C Copper Copper 316 SS 316 SS A C D E Table 4 -- Capillary Length Specify Length in feet. Standard Length = 5 Ft. Available Capillary Length: 1-100Ft. Note: Capillary Lengths over 5 feet affect bulb length. See table at bottom of page. Connection Type Material None (Plain Bulb) Jam Nut Only Brass - (For Existing Brass Well) Jam Nut Only 316 SS - (For Existing Stainless Well) 1/2" NPT Union Brass 1/2" NPT Union 316 SS 1/2" NPT Sliding Union on Bendable Extension 316 SS - (Only Avail. with 316 SS Capillary) Brass Thermowells For Vapor Actuated Bulbs (except M2) None Bronze Braid None S.S. Armor 316 SS 1/2 NPT 3/4 NPT 1/2 NPT 3/4 NPT For 1-10 ft. Capillary (bulb #1) 12B 13B 12S 13S For 11-25 ft. Capillary (bulb #2) 22B 23B 22S 23S For 26-50 ft. Capillary (bulb #3) 32B 33B 32S 33S For 51-75 ft. Capillary (bulb #4) 42B 43B 42S 43S For 76-100 ft. Capillary (bulb #5) 52B 53B 52S 53S Bulb Configurations S L S U 12" D D Plain Bulb D L U D S Union Connection Bendable Extension Thermowell Standard Bulb Dimensions (inches) CAPILLARY LENGTH PLAIN BULB L D 1 1-10 ft. (bulb #1) 11-25 ft. (bulb #2) 26-50 ft. (bulb #3) 51-75 ft. (bulb #4) 76-100 ft. (bulb #5) 2 /2 (1-5ft.) 7 3 /16 (6-10ft) 7 /16 7 4 /8 7 7 /8 7 10 /8 3 3 3 /8 /8 3 /8 3 /8 3 /8 UNION CONNECTION U S D 13 2 1 3 1 /16 /2 1 4 /2 1 6 /2 1 8 /2 2 3 /8 7 1 /4 1 5 /4 1 7 /4 1 9 /4 7 /16 /16 7 /16 7 /16 7 /16 THERMOWELL U S D 15 1 /2 9 3 /8 3 5 /8 3 7 /8 3 9 /8 9 /16 2 5 3 1 /8 5 4 /8 5 6 /8 5 8 /8 2 /16 /16 9 /16 9 /16 9 /16 BENDABLE EXT. S D 1 2 /2 (1-5ft.) 3 - 13 3 /8 7 3 /16 (6-10ft) 4 - 14 L 7 /16 7 4 /8 7 7 /8 7 10 /8 3 4 - 14 3 5 - 15 3 8 - 18 11- 21 /8 /8 3 /8 3 /8 19 Filled System Thermometers Vapor Actuated Dial Faces Typical dial faces shown below; complete list shown on page 19. Operating temperatures should be in upper 2/3 of selected range. C No. 21 No. 31 F No. 61 No. 73 C No. 51 F C No. 66 F C No. 79 F C F C F C No. 81 F C F For Temperatures above or below those shown, ask for information on REOTEMP Gas Actuated Thermometers. Case and Mounting Dimensions (inches) Front Flange U-Clamp Rear Flange Dial Sizes A B C D E F G H J 2" 2 1/2" 2.94 3.69 2.25 2.81 2.94 1.28R 1.66R 2.05 2.56 1.28R 2.3 0.14 0.17 3 1/2" 4.75 3.97 4.75 2.16R 3.59 2.16R 3.69 0.16 4 1/2" 5.88FR 6.31FL 5.88RR,RB 5.83TB 2.69R 4.59FR 47RR, RB, FL 0.98 1 1.41RF .75UC, FF 1.41RF .75UC, FF 2.56TB 1.63FL 2.69R 4.69 0.22 REOTEMP INSTRUMENT CORPORATION Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com 20 Filled System Thermometers R E G I S T E R E D Gas Actuated REOTEMP Gas Actuated Thermometers combine advanced gas coil technology with a state-of-the-art adsorbent (Class IV) thermal system, producing superior temperature measurement instrument that can be fitted to a wide variety applications Features include high accuracy, low ambient error, no head error, and a high degree of over-range protection. The compact (3/8” dia. x 3” active length) bulb, and a wide range of case styles and thermal systems, allow great flexibility in installation. The linear dial on all REOTEMP gas thermometers provides a consistent 1% accuracy across the full span of each range. This, combined with over twenty Fahrenheit and dual ranges, from -320 F to +1200 F, provides complete coverage of all normal temperature requirements. Specifications Accuracy: +/- 1 % of full scale. Calibration to NIST Windows: Glass is standard. Shatterproof glass traceable standards. and acrylic are optional. Ranges: Twenty °F and °F & °C ranges available from -320°F to 1200°F. Pointers: Slotted adjustable type to permit zero- Overrange: Minimum 50% of span above top of range, or 1300°F, whichever is less. Ambient Error: 1/4% of span per 25°F change in ambient temperature at midscale. Dial Sizes: 41/2"& 6". Dials are white with black mark- set adjustments. Bulbs: 316 Stainless Steel, 3/8" dia. x 3" active length. Other diameters and lengths are available. Process Connections: Plain bulb; 1/2" NPT sliding union; 1/2" NPT fixed (on All-Angle); or thermowell. Note: Thermowells should be used whenever the bulb would be exposed to pressure, fluid velocity, or corrosive or abrasive media. ings. Thermal Systems: Stainless steel capillary with Case Materials: Stainless steel, Phenolic, or Aluminum. stainless steel spring armor (up to 40ft). Over 40 feet, stainless steel interlock armor is standard. Direct mount stems, 316 SS, 4" to 48". Case Styles: Panel Mount, Surface Mount, or Direct (stem) Mount. 21 Filled System Thermometers Gas Actuated - How to Order Table 1 Case Size & Style Table 2 Thermal System & Bulb Table 3 Capillary Length (feet) G G Table 5 Options Table 4 Temperature X L 4 5 E R – 8 7 Table 1-Case Style CASE CODE Wall Mount (“E” or “K” case) A G45ER G45EL B “E” Case Phenolic Turret Mount – L 1 5 – CASE DIAMETER CONNECTION 41/2" 41/2" F B – X A W Panel Mount (“F”, “S” or “U” case) 3 HOLES G DIA. ON H BOLT CIRCLE REAR LOWER “F” Case Aluminum D Front Flange Hinge Ring C F F D 1 REAR G60FR 6" REAR A G45KR 41/2" REAR A G45FR 3 HOLES G DIA. ON H BOLT CIRCLE E A “K” Case S.S., Back Flange 1 LOWER G60KR G60KL 6" 6" REAR LOWER G45SR 41/2" REAR G60SR 6" REAR G45DA 41/2" ADJUST G60DA 6" ADJUST G45UR 41/2" REAR G60UR 6" REAR G45KL C 3 HOLES G DIA. ON H BOLT CIRCLE /2" 4 /2" 4 B .44 3 HOLES G DIA. ON H BOLT CIRCLE “S” Case S.S., SemiFlush Front Flange D C .75 B Direct Mount (“D” case) 360° ROTATION “D” Case S.S., All-Angle Direct Mount B E A F B “U” Case S.S., D U-Clamp A 180° ROTATION .88 PANEL .5 MAX THK Case Dimensions Case Size Case Type A B C D E F G H 5.83 2.56 5.08 2.62 1.0 .20 .24 5.39 1.63 - 4.88 - 1.35 .19 5.38 2.15 5.04 - - - 0.22 5.38 41/2" “E” 41/2" “F” Front Flange 6.31 41/2" “K” Back Flange 5.88 Turret Phenolic 41/2" “S” Semi-Flush 5.88 2.15 5.04 4.51 - 1.00 0.22 5.38 41/2" “D” All Angle 5.04 2.00 - - 1.70 - - - 41/2" “U” U-Clamp 5.04 - - 4.51 - - - - 6" “F” Front Flange 7.87 1.59 - 6.34 - 1.75 0.19 6.69 6" “K” Back Flange 7.50 2.15 6.38 - - - 0.25 6.84 6" “S” Semi-Flush 7.50 2.15 6.38 5.88 - 1.00 0.25 6.84 6" “D” All Angle 6.38 2.15 - - 1.70 - - - 6" “U” U-Clamp 6.38 - - 5.88 - - - - REOTEMP INSTRUMENT CORPORATION 22 Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com Filled System Thermometers Gas Actuated R E G I S T E R E D Table 2-Thermal Systems (all bulbs & capillaries are 316 SS) CODE DESCRIPTION All Angle Direct Mount with 1/2” NPT (with “D” case only) Stem Length All Angle Bulb 04 4” stem x 3/8” diameter 06 6” stem x 3/8” diameter 09 9” stem x 3/8” diameter 0X 12” or longer stem x 3/8” dia. - specify stem length .38 DIA. 3" Active Length 1/2" NPT EXAMPLE: G45DA - 0X - 12” FB #11 bulb Plain Bulbs 11 BULB/316, S.S. .38 DIA. EXT/316, S.S. .38 DIA. Plain bulb, 3/8” x 3” active, + 12” rigid extension ARMOR #12 bulb 12" 3" Active Length ARMOR .38 DIA. 12 Plain bulb, 3/8” x 3” active REINFORCING SPRING, S.S Sliding 1/2” NPT on Bendable Extension 3" Active Length Bendable Extension 1/2" NPT 87 3/8” x 3” active, 12” bendable extension 88 3/8” x 3” active, 18” bendable extension 8X 3/8” x 3” active, over 18” bendable (Specify) .38 DIA. 3" Extension Length Active Length Table 3-Capillary Length Specify Armored Capillary Length in Feet, up to 99 ft. (omit for “D” case). L05 = 5 feet L10 = 10 feet L15 = 15 feet…etc. Note: Stainless steel spring armor is standard protection on all capillary. Capillary over 40 feet requires XSI Spiral Interlock Armor option. Table 4-Temperature Ranges CODE FB FE FG FH FJ FL FN FP FR FT °F RANGES DIV. CODE -320/100°F -120/120°F -40/180°F 0/120°F 60/120°F 20/240°F 0/300°F 50/550°F 50/750°F 400/1200°F 5° 2° 2° 1° 1° 2° 5° 5° 5° 10° DB DE DG DH DJ DL DN DP DR DT °F & °C RANGES -320/100°F / -200/40°C -120/120°F / -85/50°C -40/180°F / -40/80°C 0/120°F / -15/50°C 60/120°F / 15/5°0C 20/240°F / -5/110°C 0/300°F / -10/150°C 50/550°F / 10/290°C 50/750°F / 0/400°C 400/1200°F / -200/650°C DIV. 5°/2° 2°/1° 2°/2° 1°/1° 1°/1/2° 2°/1° 5°/1° 5°/5° 5°/5° 10°/5° Note: °C Ranges available on request 23 Filled System Thermometers Gas Actuated Table 5 - Accessories & Options Code Description XAW Acrylic Window (41/2" Cases only; not available in “F” Case). XSG Safety Glass Window (41/2" Cases only; not available in “F” Case). XMH Maximum or Minimum Hand. XMM Maximum and Minimum Dual Hands. XFR Flush Mounting Ring for “E” Case. XBF 1/2" NPT Fitting for #11 Bulb - Fits on Bulb or extension. XCF 1/2" NPT Fitting - Fastens on spiral interlock armor (requires XSI option). XSI Spiral Interlock Armor (required over 40 feet). XVD Vibration Dampening feature (dampens vibration - available in all rear connected models). XTW Thermowell (see thermowell table below for order codes). Thermowells for 3/8” dia. Elements Lagging Wells Standard Wells External Thread P 3/4" NPT 1" NPT Stem length A" Insert Length U" Order Code 304 s.s. 316 s.s. 4 6 9 12 15 18 24 2 1/2 4 1/2 7 1/2 10 1/2 13 1/2 16 1/2 22 1/2 046 047 048 049 050 051 052 146 147 148 149 150 151 152 4 6 9 12 15 18 24 2 1/2 4 1/2 7 1/2 10 1/2 13 1/2 16 1/2 22 1/2 053 054 055 056 057 058 059 153 154 155 156 157 158 159 External Thread P Stem length A" Insert Length U" Lag Ext. T" 3/4” NPT 6 9 12 15 18 24 2 1/2 4 1/2 7 1/2 10 1/2 13 1/2 16 1/2 2 3 3 3 3 3 Order Code 304 s.s. 316 s.s. 247 248 249 250 251 252 STEM LENGTH A 1 /2" NPSM STEM LENGTH A .385 DIA 1 /2" NPSM How to Order Specify “TW” Plus Order Code Example: TW-146 REOTEMP INSTRUMENT CORPORATION 24 Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com 347 348 349 350 351 352 Filled Systems Thermometers Direct Drive Gas Actuated R E G I S T E R E D Available in Four styles 45GW 45GF 45GFF 45GAW WALL MOUNTED FLUSH MOUNTED FRONT FLANGE ADJUSTABLE WALL Specifications CASE: Stainless Steel (SS) DIAL FACE: 4 1/2" Satin Finish Aluminum, Black Lines and Numbers. Gasket Sealed Glass (Plexi Glass Optional) Micrometer Adjustment Type LENS: POINTER: CAPILLARY: SS Protected by 1/4" Dia. Flexible SS Armor or 3/16" Dia. Plain Armor BULB: SS Welded Construction ACTUATION: Nitrogen thru SS Direct Drive Bourdon Coil ACCURACY: +/- 1 % of Range Span REOTEMP’s Rugged Direct Drive System makes our 45G series gas – actuated series the right choice for temperature indication in heavy duty or high vibration applications. Its all-stainless steel case and internals, along with the direct drive system, result in superior instrument life in severe environments. NITROGEN FILLED DIRECT DRIVE SYSTEM Temperature Ranges Celsius Ranges 00 01 02 04 05 06 07 08 09 10 11 12 13 14 39 -200/100°C -100/100°C -30/60°C -10/80°C -30/120°C -10/150°C 0/100°C 0/200°C 0/240°C 0/300°C 0/400°C 100/400°C 0/500°C 0/600°C 0/50°C Fahrenheit Ranges 16 17 19 20 21 23 24 25 26 27 30 31 32 33 34 36 38 -350/150°F -100/100°F -40/120°F -40/200°F 0/100°F 0/150°F 25/125°F 0/200°F 0/240°F 0/300°F 0/400°F 0/500°F 0/600°F 150/750°F 0/800°F 0/1200°F 20/240°F 25 Filled Systems Thermometers Direct Drive Gas Filled Remote Case Specifications Model 45GAW Model 45GW Adjustable Wall Mounted Complete with Flange Wall Mounted Complete with Bracket Model 45GF Model 45GFF Flush Mounted Complete with U - Bracket Flush Mounted Complete with U - Bracket Bulbs G1 G2 12” 3/8” dia. bulb with 3/16” bendable complete with 1/2” NPT compression fitting; All SS 3/8” dia. bulb with 3/8” extension up to 48” with optional 1/2” NPT compression fitting; All SS How to Order 45GW Model 06 Armored Capillary Temperature Length Range 45GW = Wall Mount 05 = 5 Feet 45GF = Flush Mount 06 = 6 Feet 45GFF = Front Flange 45GAW = Adjustable Wall Mount 08 10 = 10 Feet Other = Specify Length in Feet See chart on Page 25. G118 Bulb Type G112 = 12" Bendable Extension with 1/2" NPT Union G118 = 18" Bendable Extention with 1/2" NPT Union G212 = 12" Plain Bulb with Rigid Extension G224 = 24" Bendable Extension with 1/2" NPT Union 45SG Accessories for Thermowells see pg. 24 EC = Electrical Contacts MP = Max Hand Pointer SG = Tempered Glass PC = Polycarbonate Crystal REOTEMP INSTRUMENT CORPORATION 26 Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com Filled Systems Thermometers Direct Drive Gas & Liquid Filled R E G I S T E R E D REOTEMP’s Rugged Direct Drive System makes our 45GR and 45LR the right choice for temperature indication in heavy duty or high vibration applications. Its all-stainless steel case and internals, along with the direct drive system, result in superior instrument life in severe environments. EVERY ANGLE MODEL 45LR Specifications: CASE: DIAL FACE: LENS: POINTER: BULB: Stainless Steel (SS) 4 1/2" Satin Finish Aluminum, Black Lines and Numbers Gasket Sealed Glass (Polycarbonate Optional) Micrometer Adjustment Type SS Welded Construction ACTUATION: 45 LR - Inert Liquid thru SS Direct Drive Bourdon Coil (For *ranges, Nitrogen thru SS), Direct Drive Bourdon Coil. 45GR - Nitrogen thru SS Direct Drive Bourdon Coil. MODEL 45GR ACCURACY: +/- 1 % of Range Span How to Order 45GR Model 45GR = Gas Actuated 3/8" Stem 45LR = Inert Liquid Actuated, 1/4" Stem 06 ST6 316 08 Armored Temperature Capillary Length Range Accessories 02 = 2 1/2" (LR Only) Standard Thermowells (3/4"NPT, 316SS) 04 = 4" Stem "U" 1/4" 06 = 6" Length Dim. element element 09 = 9" 4" 2.5" ST4316 GXTW146 6" 4.5" 9" 7.5" ST6316 ST9316 GXTW147 GXTW148 p. 14 p. 24 ) 12 = 12" 15 = 15" See chart on Page 25. (More wells on: 3/8" EC = Elec. Connection SG = Tempered Glass MP = Max Pointer PC = Plastic Crystal 27 Digital Thermometers Hand-Held Thermometers Durable, shock resistant ABS plastic carrying case Easy-to-read, backlighted LCD displays both °F and °C Model 701K - Pocket Size Magnet on back - stick it anywhere In Stock in °F; Also available °C. Sealed membrane touch pad Features • • • • Features Model TM99A All Solid State (with disposable battery) High Accuracy Model TC100A (with rechargeable battery) Detachable Probes Wide Temperature Ranges Accuracy Ambient Range Display Probe Size Model HI 9063 HI 9063 Greater of ±0.3 F, or ±0.5% of reading 0 To 150 F max, RH -90%, noncondensing Backlighted .4" LCD #1075 10K Thermistor, detachable Type K Thermocouple TM99A - 9V alkaline battery (provided) 4 - 1.5V AAA batteries TC100A - 9V NiCad battery with 110V charger 9 1/2" x 6 1/2" x 2 1/2" (case closed) 7.7" x 3.1" x 2.4" (196 x 80 x 60mm) 1. Specify Model #. 2. Specify Probe. Model # 701K Hand-Held Thermometer Models Thermistor Models Disposable Battery 1075 TC100A Rechargable Battery "K" Thermocouple Models 4040 Compact HI9063 Full Functioned Probe SPK1 Probes for Models: TM99A and TC100A 10K Thermistor Probes All but 2010 and 7041 have 3” handle and 48” coiled lead. Probe Model Description Dimensions 1052 701K Type K Thermocouple (Optional) 1 - 9V battery 3.1" x 2.4" x 1.1" (80 x 60 x 33.5mm) Probes for Models: How to Order TM99A 701KF C/LO Mode: -50 TO 150 C with 0.1 C Resolution C/HI Mode: -50 TO 950 C with 1 C Resolution -50 To 1,000 F with 1 F Resolution F/LO Mode: -58 TO 302 F with 0.1 F Resolution F/HI Mode: -58 TO 1742 F with 1 F Resolution ±0.3% Full Scale / ±3 C (hi), ±0.6 C (lo) ±.25%* (±1 Digit) -10 TO 50 C (14 To 122 F) RH 100% 32 TO 104 F -40 F TO +300 F (-40 C TO +150 C) 0.1 F or C Resolution Range & Resolution All Solid State High Stability Cold Junction Compensation Wide Temperature Ranges Water Resistant Min - Max, °F/°C TM99A TC100A Specifications: Power • • • • 5005 2010 S/S Immersion (comes standard) S/S Piercing Tip Probe Fast Surface Probe Air Probe General Purpose Probe HI 9063 and 701KF Thermocouple Probes (intermediate sizes, or industrial configurations avalaible on application) Probes have 4” handle and min. 36” lead, except where noted. Probe Model Description Dimensions LPK5 XPK2 Immersion/General Purpose Fast Response (no handle) Fast Response Piercing Tip .142" x 4" FRK4 HPK2 REK1 .041" x 2.8" SPK1 Surface Temperature LPKA Gas Temperature LPK12 Heavy Duty General Purpose .125" x 4" .18" x .6" Soft-wire Disposable (no handle) .156" x 5" 1/16" x 12" 1/16" x 4" .156" x 4" exposed tip 48" MRK36, Heavy Duty .40" x 36", 48" or 60" 48,60 Penetration (pointed) REOTEMP INSTRUMENT CORPORATION 28 1/4" x 12" Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com Thermocouples & RTD’s R E G I S T E R E D RTD’s (Resistance Temperature Detectors) How Howto toOrder: Order Construct part number from table D below. For Thermowell Assembly: Insert part number obtained below into assembly part number on page 31. RTD Styles TABLE D Resistance Temperatures Detectors STEP 1 - RTD Style A B A standard RTD Assembly may be supplied with an adjustable compression fitting. Specify. Welded Choose from “Styles” table. Insert letter below. (for thermowell assemblies, specify style “A”) STEP 2 - Sensor Material (Px is standard) 1 /2 NPT Std. B B A standard 1/2 x 1/2 NPT stainless bushing is welded to the element sheath. 1/4 x 1/4 and 3/4 x 3/4 are available. Specify. Insert letter designated below. Px - Platinum 0.00385 Ω/Ω/°C P - Platinum 0.00392 Ω/Ω/°C Pl - Platinum 0.00390 Ω/Ω/°C N - Nickel 0.06725 Ω/Ω/°C C - Copper 000421 Ω/Ω/°C Ba - Balco STEP 3 - Temperature Insert single-digit number designated below. 1 (standard) -200 / +400°F (-130 TO +200°C) 2 (hi temp) -200 / +1100°F (-130 To +600°C) C A quick-disconnect male plug is mounted on the cold end of the element. Two or three prong standard plugs are available. Two prong miniature plugs are available. Specify. Special Ranges available on application STEP 4 - Sheath Diameter Insert two-digit number designated be designated below. 18 = .188 dia. 25 = .250 dia. 37 = .375 dia. STEP 5 - Sheath Material D A quick-disconnect female jack is mounted on the cold end of the element. Two or three prong standard jacks are available. Two prong miniature jacks are available. Specify. Insert single-digit number designated below. 1 = 316 SS 3 = 304 SS 5 = INC 600 STEP 6 - Resistance 32°F (0°C) Ohms ±.5% (#1 IS STANDARD) Insert single-digit number designated below. (STD) Platinum - 1 = 100 Ohms 2 = 200 Ohms 5 = 500 Ohms Nickel 7 = 120 Ohms Copper 8 = 10 Ohms E STEP 7 - Determine the required length “L” in inches For Thermowell assemblies, specify “AR” (as required) This RTD is terminated with an “O” ring seal. Canister Head. STEP 8 - Number of Leads/RTD’s Spring Loaded 1 /2 NPT Std. H B A standard 1/2 x 1/2 NPT stainless hex bushing allows the element to be spring-loaded up to 1/2. Single RTD W X Y Leads/RTD 2-wire 3-wire 4-wire Duplex RTD WW XX YY STEP 9 - Lead Length Need something you don’t see? Call REOTEMP for information. •1-800-648-7737• Specify lead length “B” in inches. (Omit for T/W assemblies, or where N/A) 29 Thermocouples & RTD’s Mineral Insulated Thermocouples TABLE C Thermocouples STEP 1 Metal Sheathed Thermocouple Assembly - Insert “M” How HowTo to Order: Order Construct part number STEP 2 - Sheath Diameter Insert 2 digit number designated below. 12 = .125in. 18 = .188in from table “C”. 25 = .250 in. 37 = .375in. STEP 3 - ANSI Type Thermocouple Element Insert designation below. K = Chromel Alumel T = Copper Constantan J = Iron Constantan E = Chromel Constantan For Thermowell Assembly: Insert part number obtained below into assembly part number on page 31. STEP 4 - Type of Sheath Material Insert single-digit number designated below. 1 = 316 SS 1700°F (927°C) 3 = 304 SS 1650°F (899°C) 2 = 310 SS 2100°F (1149°C) 5 = Inconel 600 2100°F (1149°C) STEP 5 - Style Choose style from “Styles Table”. Insert letter(s) below. (For thermowell assemblies specify “A”) STEP 6 - Number of Element S = Single element assembly D = Dual element assembly STEP 7 - Type of Junction Elements: G = Grounded U = Ungrounded STEP 8 - Probe Length Length “L” in inches. For complete assembly with thermowell specify “AR” (as required). STEP 9 - Specify Lead Length “B” in inches (omit for thermowell assemblies, or where n/a) M Thermocouple Styles Thermocouple Styles A B Plain sheath with wire leads. Cold end epoxy sealed. Choose this style for Thermowell assemblies. Welded 1 D Female Mini-plug is mounted to cold end of sheath. Standard size plug available (specify). /2 NPT Std. Spring Loaded 1 /2 NPT Std. B B A standard 1/2 x 1/2 NPT stainless bushing is welded to the element sheath. C Male Mini-plug is mounted to cold end of sheath. Standard size plug available (specify). H B A standard 1/2 x 1/2 NPT stainless bushing allows the element to be Spring Loaded up to 1/2". Need something you don’t see? Call REOTEMP for information. •1-800-648-7737• REOTEMP INSTRUMENT CORPORATION 30 Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com Thermocouples & RTD’s Thermowell Assemblies R E G I S T E R E D How to Order Screw Cover Head Table A Below Example: B Threaded Connection Table B Below – 1 L – M 25 K 3 TABLE A Screw Cover Heads UNIVERSAL CAST IRON TYPE A • • • • Thermowell Table E (p.32) optional Probe Element Thermocouples - Table C (pg.30) or RTD’s - Table D (pg.29) Universal head Cast iron Heavy Duty 1/2 NPT process with 3/4 NPT conduit is standard UNIVERSAL CAST ALUMINUM A S G AR – TABLE B S T 4 3 0 4 Threaded Connection Configuration CONFIGURATION: Dimensions are approximate. (with thermowell, sheath length “L” does not have to be specified) TYPE B Stems are spring loaded* for positive contact with bottom of thermowell. Standard Steel Fittings 316 SS Fittings 1L 1T 2L 2T 3L 3T 4L 4T Head-Bushing • Universal head • Cast aluminum • 1/2 NPT process with 3/4 NPT conduit is standard L 5 115/8"* /8" (Nominal) Head-Nipple FDA WHITE POLY TYPE S • Screw cover Poly head • Impervious to most corrosive media • 1/2 NPT process with 3/4 NPT conduit • SS Chain & Screws 2-1/2"* 21/2" (Nom.) L Head-Nipple-Union 3"* 3" (Nom.) EXPLOSION PROOF TYPE E • Explosion Proof • Cast aluminum body & cap • For use with two wire transmitter • Rated for Class I, Groups C, D, Class II, Groups E, F, G, Class III • 1/2 NPT process with 1/2 NPT conduit is standard Transmitters - Specify 4-20mA transmitter by adding “X” to head type. Example: Type B head with Transmitter = BX (specify Temp. Range) Terminal Blocks - Standard in all heads. L Head-Nipple-Union-Nipple 5” 5"*(Nom.) L * For welded SS fittings, substitute”F” for “T” Example: 1F Also Available: • • • • • Thermocouple Wire Transmitters Multipoint Thermocouple Assemblies Protection Tubes Stainless Steel Fittings 31 Thermocouples, RTD’s & Accessories Finished Assemblies - Ready to Go Popular Thermocouple & RTD Assemblies • Type K or J Thermocouple (single element, ungrounded) • Weatherproof Cast Aluminum Screw Cover Head, with Terminal Block • 316 SS Bushing, or steel Nipple • 1/4" dia. 316 SS Spring-loaded Stems, 4"’ 6"’ 9"’ or 12 “ • Available for fast delivery Head-Bushing Assemblies Head-Nipple-Union-Nipple Assemblies L Thermocouples Thermocouples Stem (L) 4" 6" 9" 12" Type K Type J B1TM25K1ASU4 B1TM25K1ASU6 B1TM25K1ASU9 B1TM25K1ASU12 B1TM25J1ASU4 B1TM25J1ASU6 B1TM25J1ASU9 B1TM25J1ASU12 Stem (L) 4" 6" 9" 12" Type K Type J B2LM25K1ASU4 B2LM25K1ASU6 B2LM25K1ASU9 B2LM25K1ASU12 B2LM25J1ASU4 B2LM25J1ASU6 B2LM25J1ASU9 B2LM25J1ASU12 RTD’s (3-wire, 100 ohm) Stem (L) Model # B2TAPX125114X 4" B2TAPX125116X 6" B2TAPX125119X 9" 12" B2TAPX1251112X RTD’s (3-wire, 100 ohm) Stem (L) 4" 6" 9" 12" L 5"* 1 5/8"* Model # B1TAPX125114X B1TAPX125116X B1TAPX125119X B1TAPX1251112X R E G I S T E R E D Table E Thermowells - Common Threaded Thermowells (3/4"NPT external thread). Stem Length "U" Dim 4" 6" 9" 2 1/2" 4 1/2" 7 1/2" 1/4" DIA. ELEMENTS 304 SS 316 SS ST4304 ST6304 ST9304 ST4316 ST6316 ST9316 For other similar wells, see complete listing, p. 14. Stem Length "U" Dim 4" 6" 9" 2 1/2" 4 1/2" 7 1/2" 3/8" DIA. ELEMENTS 304 SS 316 SS GTXW046 GTXW047 GTXW048 GTXW146 GTXW147 GTXW148 For other similar wells, see complete listing, p. 24. Field- Cuttable Thermocouples & RTD’s • Adjustable probe length, 2.5" to 18" • Probe is cut with simple tube cutter • One size fits many - simplify inventory. How to Order Thermocouples, Specify: 1. Model (TC-1350 or RTD-1340) Other Accessories: 2. Sensor type (K, J, T, E, Etc.) Description Model # Description 3. G (grounded) or U(ungrounded) Model # Example: TC-1350-K-G Cast Iron Head Terminal Block, 2-wire TCX 006 A TCX 001 T2 TCX 006 B Cast Aluminum Head TCX 001 T3 Terminal Block, 3-wire How to Order TCX BSL 22 Spring loaded Bushing TCX 001 T4 Terminal Block, 4-wire RTD’s, specify Model only. TCXT4 2 Wire Temperature Transmitter, 4-20 mA (specify calibration) Example: RTD-1340 REOTEMP INSTRUMENT CORPORATION Telephone: (800) 648-7737 FAX (858) 784-0720 · [email protected] · www.reotemp.com 32 Thermocouples & RTD’s CIP Sanitary RTD’s ROETEMP’s Santary RTD’s are designed for temperature sensing in food, dairy, beverage and pharmaceutical applications where sensor corrosion and product contamination are critical factors. Features: • Ideal for CIP (Clean-in-Place) • All Sensors Highly Polished to Exceed 3A Requirements • Quick-Connect Tri-Clamp Design • Fast Response Tip Available • Variety of Stem and Termination Options Stem Options Termination Options Connection Head Types S, Y (or Type T w/transmitter) Standard Stem Type A Immersion X 3” Sensitive Portion 1/2” FDA Compliant White Polypropylene Screw Cover Head (Standard) 1/4” OD, 316L SS S/S Sanitary Cap Reduced Tip Stem Type B, C, E Immersion X 3” 1 1/4” 316L SS Type L (with Teflon Leads) E Lead Length (STD. = 6”) 2 1/4” S/S Sanitary Cap 1/2” NPT Type D Mini-Stem with T-75 Mini-Cap Type N (with Teflon Leads) 4 1/2” 5/32” OD 3/4” Tri-Clamp All Stems are Polished 316L SS E Lead Length (STD. = 6”) 2 1/4” X Other Options Available See Easy “How to Order” guide on page 34. 33 Thermocouples & RTD’s CIP Sanitary RTD’s How to Order R L3 030 A T15 L 12 Table 1 - RTD Type α 3 wire 100 ohm; .00385µ; Table 5 - Termination Description Accuracy # Elements 1 L3 = 0.10% 1 H3 = 0.01% 2 L6 = 0.10% 2 H6 = 0.01% Maximum temperature: 400°F (204°C) Table 2 - Immersion Length (X) Length Length 020 = 060 = 2" 6" 3" 9" 030 = 090 = 4" 12" 040 = 120 = Long or intermediate lengths OK Please specify length Table 3 - Stem Style (All stems hightly polished to exceed 3-A#09-08). A= Description 1/4" Diameter B= Reduced Tip (3/16" tip OD X 3/8" sheath OD) C= Reduced Tip (1/4" tip OD X 1/2" sheath OD) D= 5/32" Diameter Tip (with T75 mini-cap only) Single Element Only E= Special HTST Fast Response Reduced Tip (3/16 tip OD X 3/8" sheath OD, response time 3 to 3.5 sec.) Available in H3 & H6 RTD Type Only. S= Std. White Polypropylene Connection Head (FDA Compliant) T= White Polypropylene Connection Head with 4-20ma Transmitter Y= White Epoxy Coated Aluminum Head L= 1/2" OD 316SS transition with (E") Teflon Leads (Specify Length, e.g. 12" =L12 ) N= 1/2" NPT 316SS Threaded Fitting with Teflon Lead (Specify Length, e.g. 6" =N6) See stem options table pg. 33 Other Available Options: • Alternate Wire Termination • Alternate Sanitary Cap Styles • Digital Indicating Meters (Suitable for Washdown) • Thermocouple Sensors (Sanitary & Industrial) (See Termination Options pg. 33) Table 4 - Sanitary Cap Tri-Clamp Caps (Triclover 16 AMP Type) Description T15 = 1.5" (Standard) T20 = 2" T30 = 3" T75 = 3/4" Fractional (with "D" stem only) Other Cap Styles Available - Please Specify • • • • RTD’s with CIP Sanitary Connected Wells Penetration Probes Chemical Resistant Thermocouples Stainless Steel Tags Other REOTEMP CIP Sanitary Products Sanitary Pressure Gauges Sanitary Thermowells Sanitary Bimetal Thermometers Sanitary Pressure Transmitters REOTEMP INSTRUMENT CORPORATION 34 Telephone: (800) 648-7737 FAX (858) 784-0720 • [email protected] • www.reotemp.com Bimetal Thermometers Surface Thermometers R E G I S T E R E D • Measures Temperature of any Specifications • Accuracy - Within 2% of full scale Head - 2” (5.08cm) Dial - White Background, blue marks & numbers Height - 1/2” (1.27cm) Weight - 2 ounces (56.7G) approx. Case - aluminum with optically clear crystal Sensing Element - precision calibrated bimetal coil Response Time - approximately 1 minute Mounting - two Alnico magnets on back • Horizontal Surface Magnetic Feet hold to any Ferrous Surface Used on Griddles, Ovens, Motors, Piping, Tanks, etc.. Front View Magnets How Order How to to Order Model # Temperature Ranges SUR-15 SUR-50 SUR-25 SUR-75 0 to 150°F/-20 to 65°C 0 to 500°F/-20 to 260°C 0 to 250°F/-20 to 120°C 50 to 750°F/10 to 400°C Protecitive Cover and Heat Collector Bimetal Sensing Element Back View Bimetal Thermometers Pocket Thermometers Analog (Dial) Models Digital Pocket Thermometer Model K-79 Model D-450 • • • • • • • • • • • • Accurate & Rugged Quick Response Shock Resistant Sensitive Bimetal Element External Reset Adjustment Waterproof and Dustproof Stainless Steel or Plastic Pocket Case Resolution 0.1°F Stainless Steel Stem, .14 x 5” Accuracy 1% of span Comes with Pocket Case 1/4” High LCD Display Also Available: D-302, -58 to 320°F Specifications Digital Specifications Model # Accuracy - 1% of Scale Head - 1” Diameter (25mm) Dial - White Background with crisp letters, marks, and numbers. Stem - .142 OD, 5” long, pointed (3.6mm x 127mm) Reset Nut - 7/16” Hex (11mm) Pocket Case - Stainless Steel or Plastic with Clip and Holder Loop Weight - .65 ounces (18.5G) Packed - 1 per box, 12 per carton Analog K-79-2 K-79-3 K-79-4 K-79-5 K-79-7 K-79-8 K-79-9 Digital D-450 D-302 Temperature Ranges -40 to 160°F 0 to 220°F 25 to 125°F 50 to 550°F -10 to 110°C 0 to 150°C 0 to 250°C Range Resolution Accuracy Display OFF Function Update D-450 D-302 -40/450° F 0.1° F ± 0.8% of span ¼” LCD 50 Min. Auto 10 Seconds -58/302° F 0.1° F ± 1% span ¼” LCD Manual 4 Seconds -40 to 450°F -58 to 302°F 35 How to