Binary Stream Gas Analyser
Transcription
Binary Stream Gas Analyser
50 Series Binary Stream Gas Analyser Analysis of your Binary Stream Features: 5.7” QVGA LCD Display Alarm/Fault Status LED Direct value reading - % or ppm Choice of TC Detectors Solenoids for Switching of Auto Zero/ Span Gas About the 50 Series The newest model of the legendary Binary Stream Gas Analyser from AGC Instruments is used to measure N2, H2, He, CO2, Ar or other gases in Binary Alarm Status Rack and Wall Mount Versions Using hotwire or thermistor elements, an analyser which has accuracy ). To interface with the analyser is via the new 90 Hydrogen Plants Chemical Plants measured & displayed to the LCD display ensuring accuracy and stability Iron & Steel Industry Gas Blending Equipment The 50 Series model contains a temperature regulated TCD which Ammonia Plants 24 hour period. The Detector consists of an electrically heated hotwire (or thermistor) through the detector will change the rate of heat loss from the element AGC Series 5500-PZ (AGC 50 Series % Unit Purged) Gas Chromatography since 1965 Air/Ar in He <10ppm N2/O2 in He Air/Ar in H2 N2/O2 in H2 <10ppm <10ppm <10ppm He/H2 in O2 Air/N2 or O2 in Ar/CO2 He in Ar/CO2 H2 in Ar/ CO2 <50ppm <100ppm <20ppm <20ppm Display Ar/CO2 in N2 <200ppm CH4 in Air <500ppm He/H2 in N2 Ar/CO2 in O2 <20ppm < 200ppm Ar/CO2 in Air He/H2 in Air <100ppm <50ppm 5.7” Touch Screen LCD Display with CCFL backlight (Backlight/Contrast adjustable) Easy to use interface Ranges 0.01 – 100% / 0.001 – 10.00%, 0-1000ppm 1ppm ±5ppm ** required) 90) < 30 seconds 1 hour typically Sample Flow Range Max inlet pressure 2 bar [200kPa] Minimum Pressure required 0.015 Bar Zero Gas requirements 1 bar Flow Measurement Visual High/Low alarms provided Detector 4-20mA Outputs Alarms Solenoids Reverse voltage protected Yes. System alarm relays providing voltage free relay contacts, High / Low / Fault Alarms, Fault alarm can be used for system debug Internal Zero/Span/ Sample solenoids provided Data Logger internally for retrieval at a later date. Power 100/115Vac. 220Vac, 50/60Hz, 300W 19” Rack / Bench Top / Wall Mounted / Purged Unit Dimensions Rack: W = 19” Rack H = 4U (180mm) D = 450mm Wall Mount: W = 500mm H = 500mm D = 300mm Weight Rack: 17 kg Pump Headquarters Shannon Free Zone West, Shannon, Co. Clare, Ireland T: +353 61 471632 F: +353 61 471042 E: [email protected] Kinetics Technology Corp. 18F-8, No.79, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221,Taiwan T: +886 (2) 26980688 F: +886 (2) 26980686 E-mail: [email protected] www.agc-instruments.com www.kinetics.com.tw