Product Catalog Decades of Evidence An original becomes a classic if the product maintains a perfect interplay of form and function for many years. FRIALIT® is one of these classics: unique design, reliable handling for decades. As the first root-analog dental implant FRIALIT® established the treatment concept of immediate implant placement more than 30 years ago. The consistent, continuing development of FRIALIT® in combination with the comprehensive FRIADENT® range of prosthetics can still meet all demands. You are always at the state of the art with this original. PLANNING CONTENT PLANNING FRIALIT® Planning Components 4 FRIALIT® Implant Package 6 FRIALIT Implants 7 FRIALIT Surgical Sets 8 ® ® FRIALIT® Surgical Unit and Contra-angle Handpieces 12 FRIALIT® Surgical Instruments 13 Prosthetics FRIALIT® Prosthetic Components SURGERY Surgery 18 FRIALIT® Prosthetic Components “Esthetic” Fabrication of suprastructure on implant level 20 FRIALIT Prosthetic Components “Multi-Purpose” Fabrication of suprastructure on gingiva level 32 FRIALIT Prosthetic Instruments 38 presentation Material 42 Materials 43 Information regarding the materials involved in implants, system components and instruments is given in the form of a reference number after every article: FRIADENT® Gingiva Former2. Page 43 of this catalog presents an overview of the materials and the composition of the materials used. The pictures in this catalog are for illustration. The size of the illustrated products may deviate from the original product. DENTSPLY Implants reserves the right to make any technical changes without prior notice. presentation MATERIAL ® PROsTHETICS ® Planning Components FRIADENT® Select order no. Article 45 – 5020 FRIALIT® Select Basic Set Complete Per implant diameter: One straight FRIADENT® Select Try-in Abutment and the D 3.4 and D 3.8/A 15 angled Select Try-in Abutment, one FRIADENT® Select Sleeve and the pin, one FRIALIT® Select Try-in Implant, Implant Forceps and one Select Tray Try-in Abutments FRIADENT® Select Try-in Abutment2 n Determination of oro-vestibular and mesio-distal implant position and of the distance to the adjacent teeth n Determination of gingival height, angulation and position of the horizontal screw (GH 2) for all FRIADENT® abutments order no. Article 45 – 2190 FRIADENT® Basic Set Select Try-in Abutment One FRIADENT® Select Try-in Abutment A 0, straight per implant diameter and one FRIADENT® Select Try-in Abutment D 3.4 and D 3.8/A 15, angled FRIADENT® Select Try-in Abutment2 45 – 2120 45 – 2121 45 – 2122 45 – 2123 D D D D 3.4 / A 3.8 / A 4.5 / A 5.5 / A 0 (straight) 0 (straight) 0 (straight) 0 (straight) 45 – 2220 45 – 2221 D 3.4 / A 15 (angled 15°) D 3.8 / A 15 (angled 15°) FRIADENT® Select Multipack Try-in Abutment (3 pieces) 45 – 2193 45 – 2194 45 – 2195 45 – 2196 D D D D 45 – 2293 45 – 2294 D 3.4 / A 15 (angled 15°, 3 pieces) D 3.8 / A 15 (angled 15°, 3 pieces) 3.4 / A 0 (straight, 3 pieces) 3.8 / A 0 (straight, 3 pieces) 4.5 / A 0 (straight, 3 pieces) 5.5 / A 0 (straight, 3 pieces) Sleeves FRIADENT® Select Sleeves Exact transfer of the pre-prosthetic planning to the clinical situation order no. Article 45 – 5090 FRIADENT® Select Basic Set Sleeve One FRIADENT® Select Sleeve per implant diameter and one sleeve n FRIADENT® Select Sleeve2 without pin 45 – 5035 45 – 5045 45 – 5055 45 – 5065 45 – 5075 4 D 3.4 D 3.8 D 4.5 D 5.5 D 6.5 PLANNING Sleeves order no. Article FRIADENT® Multipack Select Sleeve2 (3 pieces), without pin 45 – 5095 45 – 5091 45 – 5092 45 – 5093 45 – 5094 D 3.4 (3 pieces) D 3.8 (3 pieces) D 4.5 (3 pieces) D 5.5 (3 pieces) D 6.5 (3 pieces) Try-in Implants order no. Article 91 – 4502 FRIADENT® Khoury Drill Guide Pin2 45 – 5080 FRIALIT® Select Basic Set Try-in Implant One FRIALIT® Select Try-in Implant per implant diameter FRIALIT® Select Try-in Implant2 FRIALIT® Select Try-in Implants Intra-operative check of implant position, implant axis, congruency between implant and bone crest and peri-implant soft tissue level n 45 – 5030 45 – 5040 45 – 5050 45 – 5060 45 – 5070 D 3.4 D 3.8 D 4.5 D 5.5 D 6.5 FRIALIT® Multipack Select Try-in Implant (3 pieces) 45 – 5085 45 – 5081 45 – 5082 45 – 5083 45 – 5084 D 3.4 D 3.8 D 4.5 D 5.5 D 6.5 others order no. Article 48 – 0040 FRIALIT® Select Tray (empty) FRIADENT® Depth Gauge2 45 – 5104 45 – 5100 D 2.0 D 3.0 49 – 1211 FRIADENT® Radiographic Balls for pre-surgical planning6 Ø 5 mm, 12 pieces 45 – 5570 FRIALIT® Radiographic Template (Scales 1:1; 1,3:1; 1,7:1) 5 Implant Package FRIALIT® implants are supplied in a double-sterile blister package with an outer carton. The type of package offers the maximum product safety in conformance with the increasingly rigid requirements for medical devices. The packaging also makes it easy to store all products for quick retrieval and they are easy to handle during the surgical procedure. All other DENTSPLY Implants products for surgery and prosthetics are also sealed in blisters in branded cardboard packages. Outer box package Simple product classification with brandspecific design, sight window and color-coded imprint of the implant diameter n Large seal label with details of products n Stackable, all important product information remains visible n Includes multilingual instructions for use n Transparent outer blister Outer sterile barrier of implant package n Transparent inner blister Inner sterile package n Contains implant shuttle with implant and cover screw for implants n Peel-off label with batch code for reliable documentation of treatment n Plastic implant shuttle Holds the implant securely in the packaging and protects it from damage during transport and removal n Makes non-contact transfer and acceptance of the implant easy during the operation n Three wings with roughened surfaces for non-slip holding make it very easy to handle safely n 6 Implants FRIALIT ® Implants Article FRIALIT® plus Stepped Screw (sterile) Content: Stepped Screw, Placement Head2 and Cover Screw2 36 – 2431 36 – 2433 36 – 2435 D 3.4 / L 113 D 3.4 / L 133 D 3.4 / L 153 36 – 2441 36 – 2443 36 – 2445 D 3.8 / L 112 D 3.8 / L 132 D 3.8 / L 152 36 – 2450 36 – 2451 36 – 2453 36 – 2455 D D D D 4.5 4.5 4.5 4.5 / / / / L L L L 82 102 132 152 36 – 2460 36 – 2461 36 – 2463 36 – 2465 D D D D 5.5 5.5 5.5 5.5 / / / / L L L L 82 102 132 152 36 – 2471 36 – 2473 36 – 2475 D 6.5 / L 102 D 6.5 / L 132 D 6.5 / L 152 Indications Single-tooth replacement n Fixing bridges and prostheses n Healing mode Submerged or transgingival with gingiva-forming components or temporary dentures n INSTRuMENTS Loosening of Placement Head (after placing the implants in the cavity): FRIADENT® Hex-Driver 0.9 mm (page 17) Insertion of implants FRIALIT® Stepped Screw Implant Driver (page 16) Placement of Implant Cover Screw FRIADENT® Hex-Driver 0.9 mm or FRIADENT® Slot Screwdriver 2.0 mm (page 17) FRIADENT® Implant Cover Screw2 45 – 1130 45 – 1140 45 – 1150 45 – 1160 45 – 1170 D 3.4 D 3.8 D 4.5 D 5.5 D 6.5 7 SuRGERy order no. Surgical Sets FRIALIT® Drill Sequence A successful implant placement requires precise and careful implant site preparation. Therefore, please follow our recommendations for drilling exactly. FRIALIT® Stepped Screw D 3.4 FRIALIT® Stepped Screw D 3.8 FRIALIT® Stepped Screw D 4.5 FRIALIT® Stepped Screw D 5.5 FRIALIT® Stepped Screw D 6.5 8 FRIALIT® Twist Drill D 2.0 FRIALIT® Round Drill FRIALIT® Stepped Drill D 3.4 For type I bone Cortical Drill D 3.8 FRIALIT® Stepped Drill D 3.8 Cortical Drill D 4.5 FRIALIT® Stepped Drill D 4.5 FRIALIT® Stepped Drill D 5.5 Cortical Drill D 5.5 FRIALIT® Stepped Drill D 6.5 Cortical Drill D 6.5 a maximum speed of 400 to 500 rpm. During the preparation make sure drills are adequately internally and externally irrigated. FRIALIT® Cortical Drill Dense cortical bone (type I bone) frequently exhibits elastic forces after implant site preparation. Additional preparation of the top step with the FRIALIT® Cortical Drill can compensate for this effect. The FRIALIT® Cortical Drill gently expands the implant site as required by increasing the diameter of the first step by 1/10 mm and thus allows for an easy and atraumatic implant insertion avoiding a too high insertion torque. option: FRIALIT® BoneCondenser In cases of poor bone quality, FRIALIT® BoneCondensers can be used for lateral and apical implant site condensation. SuRGERy FRIALIT® Twist Drills and Stepped Drills FRIALIT® Twist Drills and Stepped Drills are used at 800 rpm. In very dense cortical bone the diameter 5.5 mm and 6.5 mm stepped drills are used at This improvement of bone quality andquantity enhances primary implant stabilization. 9 Surgical Sets FRIALIT® Sets Surgical Instruments The instrument sets contain all instruments required for implant placement. The kits are supplied in the FRIALIT® Surgical Tray. order no. Article 45 – 8072 FRIALIT® BasicSet Surgery 45 – 8090 FRIALIT® ExpertSet Surgery order no. Article 48 – 0005 FRIALIT® Surgical Tray (empty) For detailed information on the content of the surgical sets please see page 11. 10 ExpertSet n n FRIALIT® Select Try-in Implant StarterSet n FRIALIT® Select Try-in Implant D 3.4 n Radiographic Balls for pre-surgical planning (5 pieces) FRIADENT® Select Try-in Abutment StarterSet n FRIADENT® Select Try-in Abutment D 3.4 n FRIADENT® Select Try-in Abutment D 3.4/A 15 BasicSet ExpertSet Handpiece Stepped Screw Implant Driver D 3.4 n Handpiece Stepped Screw Implant Driver D 3.8 – D 6.5 n Ratchet Stepped Screw Implant Driver 12 mm 16 mm 20 mm n n n n n n FRIADENT® Ratchet n n FRIADENT® Ratchet Insert for Implant Driver n n Handpiece Hex Driver, 0.9 mm n n Ratchet Hex Driver, 0.9 mm n n Handpiece Slot Screwdriver n n Contents n Fitting Tool for Depth Stops n n Depth Gauge D 2 n n Twist Drill D 2 (with 4 Depth Stops) Stepped Drill D 3.4 (with 5 Depth Stops) n n n n Ratchet Slot Screwdriver Round Drill n n Implant Forceps n n Stepped Drill D 3.8 universal (with 4 Depth Stops) Surgical Tray n n n n Stepped Drill Stepped Drill Stepped Drill Stepped Drill D 4.5 / L 8 D 4.5 / L 10 D 4.5 / L 13 D 4.5 / L 15 Stepped Drill Stepped Drill Stepped Drill Stepped Drill D 5.5 / L 8 D 5.5 / L 10 D 5.5 / L 13 D 5.5 / L 15 Stepped Drill D 6.5 / L 10 Stepped Drill D 6.5 / L 13 Stepped Drill D 6.5 / L 15 n n n n n n n n n n n n n n n n n n n n n n n Drill Extension n Long Internal Irrigation Tube n n n Cortical Drill Cortical Drill Cortical Drill Cortical Drill D 3.8 D 4.5 D 5.5 D 6.5 Drill Cleaning Instrument SURGERY BasicSet Contents 11 Surgical Unit and Contra-angle Handpieces FRIoS® Surgical Set FRIoS® unit S/i n Simple operating concept specially designed for implant surgery n Powerful, quiet running surgical motor n User-oriented program sequence with thread-tapping function actuated by pushbutton order no. Article 90 – 6600 FRIoS® unit S/i V 220 – 240 AC Scope of delivery: FRIOS® Unit S/i with handmotor (cable length 1.8 m), tray for motor, stand, foot control, mains cable, hose set, hose rings (5 pieces), locking pin for motor FRIoS® Hand and Contra-angle Pieces FRIoS® Contra-angle Handpieces n Patented hexagonal clamping system for trouble-free surgical procedures and less wear on instruments n Demountable version with head that rotates 90° for access to difficult regions, also meets the most rigid hygiene requirements n LED version with neutral white LED light and higher luminous intensity and larger field of illumination than conventional halogen lamps Note for users of FRIOS® Unit S: A comprehensive overview of accessories available for the FRIOS® Unit S/i, together with all FRIOS® hand- and contra-angle pieces, as well as the products of our FRIOS® product range for augmentation, are given in our product catalog FRIOS®, order no. 6-302017. 12 order no. Article 90 – 6720 90 – 6710 90 – 6810 FRIoS® Contra-angle Handpiece WS-75 20:1, demountable FRIoS® Contra-angle Handpiece WI-75 20:1 FRIoS® Contra-angle Handpiece WI-75 LED G 90 – 5030 90 – 5050 90 – 6850 FRIoS® Handpiece straight 1:1 FRIoS® Handpiece angled 1:1 FRIoS® Handpiece SI-11 LED G 1:1 Surgical Instruments FRIALIT® Drills Article 45 – 5102 FRIALIT® Twist Drill D 26 (with 4 Depth Stops) 45 – 5130 FRIALIT® Round Drill6 FRIALIT® Stepped Drill6 45 – 5331 D 3.4 universal (with 5 Depth Stops) 45 – 5340 D 3.8 universal (with 4 Depth Stops) 45 – 5350 45 – 5351 45 – 5353 45 – 5355 D D D D 4.5 4.5 4.5 4.5 / / / / L L L L 8 10 13 15 45 – 5360 45 – 5361 45 – 5363 45 – 5365 D D D D 5.5 5.5 5.5 5.5 / / / / L L L L 8 10 13 15 45 – 5371 45 – 5373 45 – 5375 D 6.5 / L 10 D 6.5 / L 13 D 6.5 / L 15 45 – 5101 FRIALIT® Drills n For implant site preparation up to the planned implant diameter n With internal irrigation n Adaptation of the universal FRIALIT® Twist Drill D 2 and of the universal Stepped Drills D 3.4 and 3.8 to the planned implant length with depth stops (included) Cutting instruments should generally be replaced after 20 cycles of use. Blunt or damaged instruments must be replaced immediately. FRIALIT® Drill Depth Stop Tool6 (two-piece) 45 – 5349 45 – 5359 45 – 5369 45 – 5379 FRIALIT® Cortical Drill6 D 3.8 D 4.5 D 5.5 D 6.5 45 – 5280 FRIADENT® Drill Cleaning Instrument6 91 – 0003 FRIADENT® Drill Extension6 90 – 5042 FRIoS® Contra-angle Handpiece 20:1 Irrigation Tube 90 – 5043 Long Internal Irrigation Tube (for Drill Extension) 45 – 5106 FRIADENT® Paralleling Pin2 FRIALIT® Cortical Drill For preparation of the upper step of the implant site in very dense cortical bone n The drill extension must always be used with the long internal irrigation tube. Continuing procedure: The instruments for insertion and restoration of the implants are shown on pages 16/17. 13 SuRGERy order no. Surgical Instruments FRIALIT® BoneCondenser order no. FRIALIT® BoneCondenser n For lateral and apical bone condensing in reduced bone quality n For improving bone quality and quantity with increased primary stability of implants n Universal length with depth marks at the working tips The design of the FRIALIT® BoneCondensers is similar to that of the stepped screw implants. The concave working tip can be used for application of bone regeneration material. Article FRIALIT® Instrument Set BoneCondenser, straight with tray 45 – 8550 Instruments Set for diameter D 3.8 – D 4.5 (surgical tray with 6 instruments) 45 – 8560 Instruments Set for diameter D 3.8 – D 5.5 (surgical tray with 9 instruments) 45 – 8570 Instruments Set for diameter D 3.8 – D 6.5 (surgical tray with 12 instruments) FRIALIT® Instrument Set BoneCondenser, angled with tray 45 – 8950 Instruments Set for diameter D 3.8 – D 4.5 (surgical tray with 6 instruments) 45 – 8960 Instruments Set for diameter D 3.8 – D 5.5 (surgical tray with 9 instruments) 45 – 8970 Instruments Set for diameter D 3.8 – D 6.5 (surgical tray with 12 instruments) FRIALIT® BoneCondenser, straight25/6 14 45 – 5402 45 – 5403 45 – 5440 D 2.0 D 3.0 D 3.8 45 – 5451 45 – 5453 45 – 5455 D 4.5 / L 10 D 4.5 / L 13 D 4.5 / L 15 45 – 5461 45 – 5463 45 – 5465 D 5.5 / L 10 D 5.5 / L 13 D 5.5 / L 15 45 – 5471 45 – 5473 45 – 5475 D 6.5 / L 10 D 6.5 / L 13 D 6.5 / L 15 FRIALIT® BoneCondenser Article FRIALIT® BoneCondenser, angled25/6 45 – 5902 45 – 5903 45 – 5940 D 2.0 D 3.0 D 3.8 45 – 5951 45 – 5953 45 – 5955 D 4.5 / L 10 D 4.5 / L 13 D 4.5 / L 15 45 – 5961 45 – 5963 45 – 5965 D 5.5 / L 10 D 5.5 / L 13 D 5.5 / L 15 45 – 5971 45 – 5973 45 – 5975 D 6.5 / L 10 D 6.5 / L 13 D 6.5 / L 15 48 – 0060 FRIALIT® BoneCondenser, angled n When limited space is available and for the posterior region SuRGERy order no. FRIALIT® BoneCondenser Tray5/6/26 (empty) 15 Surgical Instruments Periotome FRIADENT® Periotome n Designed for atraumatic residual root and tooth removal order no. Article 45 – 5500 FRIADENT® Periotome Handle6 FRIADENT® Periotome Blade6 45 – 5501 45 – 5502 45 – 5503 P 1 (straight, wide) P 2 (straight, narrow) P 3 (angled, narrow) Instruments for implant placement order no. Article 45 – 5709 FRIADENT® Ratchet6, without inserts6 45 – 5711 FRIADENT® Ratchet Insert for Implant Driver6 FRIALIT® Ratchet Stepped Screw Implant Driver6 46 – 5512 46 – 5516 46 – 5520 12 mm 16 mm 20 mm FRIALIT® Handpiece Stepped Screw Implant Driver4 45 – 5519 45 – 5510 16 for D 3.4 for D 3.8 – D 6.5 Drivers order no. Article 45 – 5651 FRIADENT® Handpiece Hex Driver6 Width 0.9 mm 45 – 5640 FRIADENT® Handpiece Slot Screwdriver6 Blade width 2.0 mm FRIADENT® Ratchet Hex Driver6 with torque limit Width 0.9 mm / 14 Ncm/short Width 0.9 mm / 14 Ncm/long Width 1.22 mm / 24 Ncm/short Width 1.22 mm / 24 Ncm/long SuRGERy 45 – 5732 45 – 5733 45 – 5734 45 – 5736 FRIADENT® Ratchet Slot Screwdriver6 with torque limit 45 – 5714 45 – 5722 Blade width 2.0 mm / 14 Ncm/short Blade width 2.0 mm / 14 Ncm/long 45 – 5650 FRIADENT® Hex Driver6 without torque limit Width 0.9 mm order no. Article 91 – 4510 FRIADENT® Implant Mallet6/20 91 – 4515 FRIADENT® Implant Forceps2 (titanium) The 0.9 mm FRIADENT® Hex Driver without torque limit is recommended for regions with limited access. others FRIADENT® Trephine Drill6 45 – 5654 45 – 5655 45 – 5656 45 – 5657 45 – 5658 D 3.4 D 3.8 D 4.5 D 5.5 D 6.5 17 Prosthetic Components The type of prosthetic restoration is selected according to the indication after the implants have healed or when they are uncovered. A wide range of prefabricated components is available in the FRIADENT® prosthetics range – in the implant diameters, various gingival heights, straight and angled. There are two basic procedures: n The “Esthetic” procedure with fabrication of the suprastructure at implant level The “Multi-Purpose” procedure with fabrication of the suprastructure using the MP Abutment at gingiva level n “Esthetic” procedure For reconstructions in which the esthetic aspect is in the foreground n For cemented-in and screw-retained single-tooth restorations and bridges and overdentures fixed to attachments n For fabrication of porcelain restorations (not available for all implant diameters) n For difficult initial prosthetic situations that require customized solutions n The impression is made at implant level, the laboratory selects the prosthetic abutment. Please note: FRIALIT® implants D 6.5 (green) are restored with prosthetic components D 5.5 (red). Healing Soft tissue management Impressions Prosthetic restoration SINGLE-TooTH RESToRATIoN FRIADENT® EstheticBase Page 26 SuBMERGED FRIADENT® Implant Cover Screw Page 7 FRIADENT® Gingiva Former Page 20 FRIADENT® CERCoN® Page 28 Temporary with FRIADENT® EsthetiCap Page 21 FRIADENT® CeraBase Page 28 FRIADENT® AuroBase Page 29 FRIADENT® Transfer Coping Page 23 FRIADENT® Telescopic Abutment Page 29 BRIDGES FRIADENT® EstheticBase Page 26 FRIADENT® AuroBase Page 29 TRANSGINGIVAL oVERDENTuRES FRIADENT® Gingiva Former Page 20 FRIADENT® Attachment Page 30 Temporary with FRIADENT® EsthetiCap Page 21 FRIADENT® AuroBase Page 29 FRIADENT® Telescopic Abutment Page 29 LoCAToR FRIALIT® Locator Abutment Page 31 18 “Multi-Purpose” (MP) procedure For cases in which a simple and standardized procedure has priority and the function of the restoration is the primary concern The impression is made at gingiva level above the prosthetic abutment. The abutment then remains in the patient's mouth. For screw-retained bridge constructions and removable implant-borne prostheses Please note: Cemented-in restorations cannot be fabricated using the Multi-Purpose procedure because of the restricted abutment height. n n The dentist selects and positions the prosthetic abutment at chairside before taking the impression. Healing Soft tissue management Impressions SuBMERGED BRIDGES FRIADENT® MP Abutment Page 32 Bridges on FRIADENT® Castable/Cast-to Waxing Sleeve Page 34 MP Cover Screw Page 32 MP Impression Coping Page 33 TRANSGINGIVAL MP Cover Screw Page 32 FRIADENT®PassivFit Seite 34 oVERDENTuRES Bar constructions on FRIADENT® Bar Coping Page 36 PRoSTHETICS FRIADENT® Implant Cover Screw Page 7 FRIADENT® MP Abutment Page 32 Prosthetic restoration 19 Prosthetic Components “Esthetic” FABRICATION OF THE SUPRASTRUCTURE ON IMPLANT LEVEL Soft Tissue Management, Temporary Restorations Gingiva Formers order no. FRIADENT® Gingiva Former For simple contouring of the peri-implant soft tissue n Selection according to implant diameter (D) and gingival height (GH) Article FRIADENT® Gingiva Former2 n 1 mm GH 1 2 mm 3 mm 5 mm GH 2 GH 3 GH 5 INSTRuMENTS Placement of the Gingiva Former: FRIADENT® Hex Driver 0.9 mm or FRIADENT® Slot Screwdriver 2.0 mm (page 40) FRIADENT® Gingiva Former Slim For perfect contouring of the soft tissue with limited mesio-distal space n The Transfer Coping Slim is used to make impressions (page 23) 45 – 1431 45 – 1432 45 – 1433 45 – 1435 D D D D 3.4 3.4 3.4 3.4 / / / / GH GH GH GH 1 2 3 5 45 – 1441 45 – 1442 45 – 1443 45 – 1445 D D D D 3.8 3.8 3.8 3.8 / / / / GH GH GH GH 1 2 3 5 45 – 1451 45 – 1452 45 – 1453 45 – 1455 D D D D 4.5 4.5 4.5 4.5 / / / / GH GH GH GH 1 2 3 5 45 – 1461 45 – 1462 45 – 1463 45 – 1465 D D D D 5.5 5.5 5.5 5.5 / / / / GH GH GH GH 1 2 3 5 FRIADENT® Gingiva Former2 slim n 20 45 – 1232 45 – 1233 45 – 1235 D 3.4 / GH 2 D 3.4 / GH 3 D 3.4 / GH 5 45 – 1242 45 – 1243 45 – 1245 D 3.8 / GH 2 D 3.8 / GH 3 D 3.8 / GH 5 45 – 1252 45 – 1253 45 – 1255 D 4.5 / GH 2 D 4.5 / GH 3 D 4.5 / GH 5 Gingiva Formers order no. Article FRIADENT® Gingiva Former2 Loop 45 – 1333 45 – 1335 D 3.4 / GH 3 D 3.4 / GH 5 45 – 1343 45 – 1345 D 3.8 / GH 3 D 3.8 / GH 5 45 – 1353 45 – 1355 D 4.5 / GH 3 D 4.5 / GH 5 45 – 1363 45 – 1365 D 5.5 / GH 3 D 5.5 / GH 5 FRIADENT® Gingiva Former Loop n For easy securing of suture material, thus enabling simple and safe soft tissue surgery Temporary Restorations Article FRIADENT® EsthetiCap24/32 with Screw for EsthetiCap 46 – 1730 D 3.4 / oval 46 – 1740 46 – 1745 D 3.8 / oval D 3.8 / triangular 46 – 1750 46 – 1755 D 4.5 / oval D 4.5 / triangular 46 – 1760 46 – 1765 D 5.5 / oval D 5.5 / triangular FRIADENT® EsthetiCap For esthetically demanding temporary crowns and bridges n Two anatomical cross-sections oval and triangular n Customizable by grinding or laminating n Cementable n X-ray-opaque with zirconium dioxide additives n PRoSTHETICS order no. INSTRuMENTS Placement of Screw for EsthetiCap: FRIADENT® Hex Driver 0.9 mm or FRIADENT® Slot Screwdriver 2.0 mm (page 40) 21 Prosthetic Components “Esthetic” FABRICATION OF THE SUPRASTRUCTURE ON IMPLANT LEVEL Impressions Impressions – Sets order no. FRIADENT® Transfer Coping n For transferring the implant position to the master model n Available for PickUp (open tray) and transfer technique The Transfer Coping GH 3 is used for gingiva up to 3 mm thick. Please use the Transfer Coping GH 5 for gingiva exceeding 3 mm thickness. 3 mm 5 mm GH 3 GH 5 FRIADENT® Lab Set Pickup Impression Content: Transfer Coping, PickUp Guide Pin, FRIADENT® TransferCap and Implant Analog 46 – 8233 46 – 8235 D 3.4 / GH 3 D 3.4 / GH 5 46 – 8243 46 – 8245 D 3.8 / GH 3 D 3.8 / GH 5 46 – 8253 46 – 8255 D 4.5 / GH 3 D 4.5 / GH 5 46 – 8263 46 – 8265 D 5.5 / GH 3 D 5.5 / GH 5 FRIADENT® Lab Set Transfer Impression Content: Transfer Coping, Standard Abutment Screw, FRIADENT® TransferCap and Implant Analog The head of the transfer copings is flattened on three sides. 22 Article 46 – 8133 46 – 8135 D 3.4 / GH 3 D 3.4 / GH 5 46 – 8143 46 – 8145 D 3.8 / GH 3 D 3.8 / GH 5 46 – 8153 46 – 8155 D 4.5 / GH 3 D 4.5 / GH 5 46 – 8163 46 – 8165 D 5.5 / GH 3 D 5.5 / GH 5 Impressions – Single Components order no. Article FRIADENT® Transfer Coping (Pickup Technique) with PickUp Guide Pin and FRIADENT® TransferCap 45 – 1635 45 – 1632 D 3.4 / GH 34 D 3.4 / GH 54 45 – 1645 45 – 1642 D 3.8 / GH 32 D 3.8 / GH 52 45 – 1655 45 – 1652 D 4.5 / GH 32 D 4.5 / GH 52 45 – 1665 45 – 1662 D 5.5 / GH 32 D 5.5 / GH 52 INSTRuMENTS Placement of Pickup Guide Pin and Standard Abutment Screws: FRIADENT® Hex Driver 1.22 mm or FRIADENT® Slot Screwdriver 2.0 mm (page 40) 45 – 1630 45 – 1631 D 3.4 / GH 32 D 3.4 / GH 52 45 – 1640 45 – 1641 D 3.8 / GH 32 D 3.8 / GH 52 45 – 1650 45 – 1651 D 4.5 / GH 34 D 4.5 / GH 54 45 – 1660 45 – 1661 D 5.5 / GH 34 D 5.5 / GH 54 FRIADENT® Transfer Coping Slim2 (without screw) 45 – 1239 45 – 1249 45 – 1259 D 3.4 D 3.8 D 4.5 FRIADENT® Transfer Coping Slim In cases with limited mesio-distal space n For impressions following soft-tissue contouring with the Gingiva Former Slim (page 20) n Please order PickUp Guide Pin or Standard Abutment Screw separately (page 24) n 23 PRoSTHETICS FRIADENT® Transfer Coping (Transfer Technique) with Standard Abutment Screw and FRIADENT® TransferCap Prosthetic Components “Esthetic” FABRICATION OF THE SUPRASTRUCTURE ON IMPLANT LEVEL Impressions Impressions – Single Components order no. FRIADENT® Transfer Coping Basic n For simple impression making in cases with implant divergencies n Please order PickUp Guide Pin separately FRIADENT® TransferCap For utmost precision when making impressions n Included in delivery of Transfer Copings PickUp and Transfer Technique FRIADENT® Transfer Coping Basic2 (with screw) 46 – 1632 46 – 1642 46 – 1652 46 – 1662 D D D D 3.4 3.8 4.5 5.5 45 – 1615 FRIADENT® Pickup Guide Pin4 D 3.4 – D 5.5 45 – 4305 FRIADENT® Standard Abutment Screw4 D 3.4 – D 5.5 FRIADENT® TransferCap20 Multi-Pack (3 pieces) n 24 Article 45 – 1639 45 – 1649 45 – 1659 45 – 1669 D D D D 3.4 3.8 4.5 5.5 Prosthetics/Lab Implant Analogs order no. Article FRIADENT® Implant Analog5 45 – 4030 45 – 4040 45 – 4050 45 – 4060 45 – 4070 D D D D D 3.4 3.8 4.5 5.5 6.5 FRIADENT® Implant Analog n For retaining the prosthetic components on the master model Try-in Abutments order no. Article FRIADENT® Select Try-in Abutment2 FRIADENT® Select Try-in Abutment Determination of gingival height, angulation and position of the horizontal screw (GH 2) for all FRIADENT® abutments n 45 – 2120 45 – 2121 45 – 2122 45 – 2123 D D D D 3.4 3.8 4.5 5.5 / / / / A 0 (straight) A 0 (straight) A 0 (straight) A 0 (straight) 45 – 2220 45 – 2221 D 3.4 / A 15 (angled 15°) D 3.8 / A 15 (angled 15°) FRIADENT® Select Try-in Abutment Multi-Pack (3 pieces) D D D D 3.4 3.8 4.5 5.5 / / / / A 0 (straight, 3 pieces) A 0 (straight, 3 pieces) A 0 (straight, 3 pieces) A 0 (straight, 3 pieces) 45 – 2293 45 – 2294 D 3.4 / A 15 (angled, 3 pieces) D 3.8 / A 15 (angled, 3 pieces) PRoSTHETICS 45 – 2193 45 – 2194 45 – 2195 45 – 2196 25 Prosthetic Components “Esthetic” FABRICATION OF THE SUPRASTRUCTURE ON IMPLANT LEVEL Prosthetics/Lab: Single-tooth Restorations and Bridges EstheticBase Abutments order no. FRIADENT® EstheticBase n For esthetically demanding single-tooth crowns and bridges n Available straight or angled n Customizable by grinding n Cementable or screw-retained (horizontal or transversal) GH 1 1 mm GH 2 2 mm GH 3 3 mm FRIADENT® EstheticBase straight / A 0 with Screw for EstheticBase GH 5 5 mm Horizontal Screw Retention All FRIADENT® EstheticBase Abutments are provided with a horizontal thread (M 1.4). An additional horizontal or transverse screw is necessary for horizontally screw-retained crowns (page 27). INSTRuMENTS Placement of Screw for EstheticBase and Standard Abutment Screw: FRIADENT® Hex Driver 1.22 mm or FRIADENT® Slot Screwdriver 2.0 mm (page 40) We recommend the use of special titanium drills (Gebr. Brasseler, Lemgo or Jota, Düsseldorf) for preparing the abutments. 26 Article 46 – 2131 46 – 2132 46 – 2133 46 – 2135 D D D D 3.4 3.4 3.4 3.4 / / / / GH GH GH GH 14 24 34 54 46 – 2141 46 – 2142 46 – 2143 46 – 2145 D D D D 3.8 3.8 3.8 3.8 / / / / GH GH GH GH 12 22 32 52 46 – 2151 46 – 2152 46 – 2153 46 – 2155 D D D D 4.5 4.5 4.5 4.5 / / / / GH GH GH GH 12 22 32 52 46 – 2161 46 – 2162 46 – 2163 46 – 2165 D D D D 5.5 5.5 5.5 5.5 / / / / GH GH GH GH 12 22 32 52 FRIADENT® EstheticBase angled / A 15 with Screw for EstheticBase 46 – 2231 46 – 2232 46 – 2233 46 – 2235 D D D D 3.4 3.4 3.4 3.4 / / / / GH GH GH GH 14 24 34 54 46 – 2241 46 – 2242 46 – 2243 46 – 2245 D D D D 3.8 3.8 3.8 3.8 / / / / GH GH GH GH 12 22 32 52 46 – 2251 46 – 2252 46 – 2253 46 – 2255 D D D D 4.5 4.5 4.5 4.5 / / / / GH GH GH GH 12 22 32 52 46 – 2261 46 – 2262 46 – 2263 46 – 2265 D D D D 5.5 5.5 5.5 5.5 / / / / GH GH GH GH 12 22 32 52 Screws for EstheticBase Article 46 – 4305 FRIADENT® Screw for EstheticBase4 D 3.4 – D 5.5 46 – 4403 FRIADENT® Horizontal Screw Set Standard Horizontal Screw Standard4 and Horizontal Screw Seat8 46 – 4404 FRIADENT® Horizontal Screw Set long Horizontal Screw Long4 and Horizontal Screw Seat8 46 – 4407 FRIADENT® Transverse Screw Set Standard Transverse Screw Standard4 and Horizontal Screw Seat8 46 – 4408 FRIADENT® Transverse Screw Set long Transverse Screw Long4 and Horizontal Screw Seat8 46 – 4401 FRIADENT® Horizontal Screw Standard4 46 – 4402 FRIADENT® Horizontal Screw long4 46 – 4405 FRIADENT® Transverse Screw Standard4 46 – 4406 FRIADENT Transverse Screw long4 45 – 4410 FRIADENT® Horizontal Screw Seat8 ® FRIADENT® Horizontal Screws n Fixing the crown on the oral abutment wall FRIADENT® Transverse Screws Fixing the crown on the oral and also the facial abutment wall n Double thread length for optimum stability n The horizontal screw is used as a transverse screw with D 3.4 in this case to use a sufficient number of threads n The use of horizontal retaining screws with a long head is recommended particularly for molars, because the crown generally offers wider dimensional waxing. INSTRuMENTS PRoSTHETICS order no. Placement of Horizontal Screws: FRIADENT Hex Driver 0.9 mm (page 40) 27 Prosthetic Components “Esthetic” FABRICATION OF THE SUPRASTRUCTURE ON IMPLANT LEVEL Prosthetics/Lab: Single-tooth Restorations and Bridges Ceramic Abutments order no. Please note that the indication for ceramic abutments is restricted to the front-tooth region. FRIADENT® CERCoN® Abutment n For full-ceramic restorations with best possible tooth analogy in the anterior region n Extremely stable with production from zirconium dioxide ceramic n Available straight or angled n Customizable by grinding or casting n Two shades of white, neutral or dentinee n Outstanding esthetics with brilliant light dynamics Article FRIADENT® CERCoN® Abutment32 straight / A 0 with screw 47 – 1141 47 – 2141 D 3.8 / GH 1, neutral D 3.8 / GH 1, dentine 47 – 1151 47 – 2151 D 4.5 / GH 1, neutral D 4.5 / GH 1, dentine 47 – 1142 47 – 2142 D 3.8 / GH 2, neutral D 3.8 / GH 2, dentine 47 – 1152 47 – 2152 D 4.5 / GH 2, neutral D 4.5 / GH 2, dentine FRIADENT® CERCoN® Abutment32 angled / A 15 with screw INSTRuMENTS Placement of screws: FRIADENT® Hex Driver 1.22 mm (page 40) We recommend using the ceramic-line Shaping Set by DeguDent for prepping the FRIADENT® CERCON® Abutments. The grinding process of CERCoN® Abutments requires irrigation. FRIADENT® CeraBase Two-piece abutment for high-quality ceramic single-tooth restorations in the anterior region n Ceramic sleeve with titanium core n Available in two sizes (conical and anatomical) 47 – 1241 47 – 2241 D 3.8 / GH 1, neutral D 3.8 / GH 1, dentine 47 – 1251 47 – 2251 D 4.5 / GH 1, neutral D 4.5 / GH 1, dentine 47 – 1242 47 – 2242 D 3.8 / GH 2, neutral D 3.8 / GH 2, dentine 47 – 1252 47 – 2252 D 4.5 / GH 2, neutral D 4.5 / GH 2, dentine FRIADENT® CeraBase Abutment with Standard Abutment Screw4 n INSTRuMENTS Placement of Standard Abutment Screw: FRIADENT® Hex Driver 1.22 mm or FRIADENT® Slot Screwdriver 2.0 mm (page 40) Grinding of the ceramic sleeve of the FRIADENT® CeraBase Abutment: FRIADENT® CeraBase ToolSet (page 40) The grinding process does not require irrigation. 28 45 – 2530 45 – 2531 D 3.4 conical30/4 D 3.4 anatomical30/4 45 – 2540 45 – 2541 D 3.8 conical30/3 D 3.8 anatomical30/3 45 – 2550 45 – 2551 D 4.5 conical30/3 D 4.5 anatomical30/3 45 – 2560 45 – 2561 D 5.5 conical30/3 D 5.5 anatomical30/3 Cast-to Abutments order no. Article FRIADENT® AuroBase20/8 with Standard Abutment Screw4 45 – 2430 45 – 2440 45 – 2450 45 – 2460 D D D D 3.4 3.8 4.5 5.5 FRIADENT® AuroBase n For difficult prosthetic situations requiring individual solutions for crowns, bridges and prostheses n For compensation of severe axial divergencies n For customized waxing from the top edge of the implant with thin gingiva Telescopic Abutments Article FRIADENT® Telescopic Abutment with Standard Abutment Screw4 45 – 2630 45 – 2640 45 – 2650 45 – 2660 45 – 4305 D D D D 3.44 3.82 4.52 5.52 FRIADENT® Standard Abutment Screw4 D 3.4 – D 5.5 FRIADENT® Telescopic Abutment For simple and economic fabrication of telescopic crowns for fixing prostheses and removable bridges n For customized single-tooth crowns n Compensation of axial divergencies with customizable milling techniques n The Telescopic Abutment can be veneered with titanium ceramics (e.g., Duceratin, Ducera or Vita Titankeramik, Vita Zahnfabrik) for occlusally screw-retained single crowns. INSTRuMENTS Placement of Standard Abutment Screws: FRIADENT® Hex Driver 1.22 mm or FRIADENT® Slot Screwdriver 2.0 mm (page 40) order no. Article FRIADENT® Milling Implant6 FRIADENT® Milling Implant Fixing the prosthetic components in the milling socket n Implant analog made of special steel with stronger retainers to resist rotary forces generated by milling n 45 – 2631 45 – 2641 45 – 2651 45 – 2661 D D D D 3.4 3.8 4.5 5.5 29 PRoSTHETICS order no. Prosthetic Components “Esthetic” FABRICATION OF THE SUPRASTRUCTURE ON IMPLANT LEVEL Prosthetics/Lab: Overdentures Ball and Socket Attachment order no. FRIADENT® Ball and Socket Attachment n For fixing overdentures in the mandible n Simple protocol with option of chairside restoration n Axial divergencies can be compensated Article FRIADENT® Ball and Socket Attachment Insert2, Attachment Screw4, Socket9, with blue silicone ring and white plastic ring 45 – 3131 45 – 3132 45 – 3133 D 3.4 / GH 14 D 3.4 / GH 24 D 3.4 / GH 34 45 – 3141 45 – 3142 45 – 3143 45 – 3145 D D D D 3.8 3.8 3.8 3.8 / / / / GH GH GH GH 12 22 32 52 45 – 3151 45 – 3152 45 – 3153 45 – 3155 D D D D 4.5 4.5 4.5 4.5 / / / / GH GH GH GH 12 22 32 52 45 – 3161 45 – 3162 45 – 3163 45 – 3165 D D D D 5.5 5.5 5.5 5.5 / / / / GH GH GH GH 12 22 32 52 INSTRuMENTS Placement of Insert: FRIADENT® Seating Instrument for Attachment Insert and MP Insert (page 41) Fixation of Attachment Screw: FRIADENT® Hex Driver 1.22 mm (page 40) Activating/Deactivating the Attachment Matrix: FRIADENT® Activator/Deactivator for Ball and Socket Attachment (page 41) FRIADENT® Attachment Patrix Analog For repairing and relining overdentures n Universal for all diameters n 30 45 – 3200 FRIADENT® Attachment Matrix9 D 3.4 – D 5.5 45 – 4105 FRIADENT® Attachment Patrix Analog5 universal D 3.4 – D 5.5 LoCAToR ® Article 26 – 3301 26 – 3302 26 – 3303 26 – 3304 26 – 3305 XiVE® LoCAToR® Abutment4 D 3.4 / GH 1 D 3.4 / GH 2 D 3.4 / GH 3 D 3.4 / GH 4 D 3.4 / GH 5 26 – 3311 26 – 3312 26 – 3313 26 – 3314 26 – 3315 D 3.8 / GH 1 D 3.8 / GH 2 D 3.8 / GH 3 D 3.8 / GH 4 D 3.8 / GH 5 26 – 3321 26 – 3322 26 – 3323 26 – 3324 26 – 3325 D 4.5 / GH 1 D 4.5 / GH 2 D 4.5 / GH 3 D 4.5 / GH 4 D 4.5 / GH 5 26 – 3331 26 – 3332 26 – 3333 26 – 3334 26 – 3335 D 5.5 / GH 1.3 D 5.5 / GH 2 D 5.5 / GH 3 D 5.5 / GH 4 D 5.5 / GH 5 45 – 3349 45 – 3350 45 – 3351 45 – 3360 45 – 3352 45 – 3353 45 – 3354 LoCAToR® Replacement Male41 (4 pieces) clear, strong retention pink, light retention blue, extra light retention gray, zero retention extended range: green, strong retention extended range: orange, light retention extended range: red, extra light retention 45 – 3355 LoCAToR® Impression Coping42 (4 pieces) 45 – 3347 LoCAToR® Male Processing Package Titanium43 (2 pieces) 45 – 3348 LoCAToR® Male Processing Package44 Stainless steel (2 pieces) 45 – 3356 45 – 3357 LoCAToR® Female Analog45 (4 pieces) D4 D5 45 – 3358 LoCAToR® Black Processing Replacement Male46 (4 pieces) 45 – 3359 LoCAToR® Block-out Spacer47 (20 pieces) 45 – 3361 LoCAToR® Processing Spacer48 (4 pieces) 45 – 3340 LoCAToR® Core Tool49 3-piece 45 – 3341 LoCAToR® Abutment Holder Sleeve50 (4 pieces) 45 – 3344 FRIADENT® LoCAToR® Insert for Prosthetic Ratchet6 45 – 3345 LoCAToR® Angle Measurement Guide51 45 – 3346 LoCAToR® Parallel Post46 (4 pieces) Please use the XiVE® LoCAToR® Abutments for FRIALIT® implants. A 100% compatibility is given. XiVE® LoCAToR® n Overdenture in toothless jaw on two implants n Self-righting design for easy fixation in the mouth with one click n Low height to give more room, even under limited space conditions n Flexible retention for individual determination of prosthesis fixation and balancing of axial divergencies up to 40° INSTRuMENTS Insert LoCAToR® abutment: LOCATOR® Core Tool 3-piece or FRIADENT® LOCATOR® Insert for Prosthetic Ratchet (page 41) PRoSTHETICS order no. Content LoCAToR® Male Processing Package: 2 x Matrix 2 x Block-Out Spacer 2 x Replacement Male clear, strong retention 2 x Replacement Male pink, light retention 2 x Replacement Male blue, extra light retention 31 Prosthetic Components “Multi-Purpose” FABRICATION OF THE SUPRASTRUCTURE ON GINGIVA LEVEL Transgingival Extension, Temporary Sealing MP Abutment order no. FRIADENT® MP Abutment n For simple and accurate fabrication of bridges with cast-to or, more economically, with castable waxing sleeve n For fixing overdentures by bar construction n Inserted abutments remain in the mouth, the laboratory operates on analogs n Simplified supragingival impressions and scaffold try-in The MP Abutment consists of MP Abutment Insert and MP Insert Screw. The appropriate MP Abutment is selected according to the gingival height. The number of grooves on the screw head indicates the gingival height of the matching Abutment Insert. GH 1 = 1 ring GH 2 = 2 rings GH 3 = 3 rings GH 5 = 5 rings INSTRuMENTS Placement of MP Abutment Inserts on the implant: FRIADENT® Seating Instrument for Attachment Insert and MP Insert (page 41) Fixation of MP Insert Screw: FRIADENT® Seating Instrument for MP Insert Screw (page 41) Placement of MP Cover Screw: FRIADENT® Hex Driver 0.9 mm (page 40) 32 Article FRIADENT® MP Abutment MP Abutment Insert and MP Insert Screw 46 – 2831 46 – 2832 46 – 2833 46 – 2835 D D D D 3.4 3.4 3.4 3.4 / / / / GH GH GH GH 14 24 34 54 46 – 2841 46 – 2842 46 – 2843 46 – 2845 46 – 2849 D D D D D 3.8 3.8 3.8 3.8 3.8 / / / / / GH GH GH GH GH 12/4 22/4 32/4 52/4 92/4 46 – 2851 46 – 2852 46 – 2853 46 – 2855 46 – 2859 D D D D D 4.5 4.5 4.5 4.5 4.5 / / / / / GH GH GH GH GH 12/4 22/4 32/4 52/4 92/4 46 – 2861 46 – 2862 46 – 2863 46 – 2865 D D D D 5.5 5.5 5.5 5.5 / / / / GH GH GH GH 12/4 22/4 32/4 52/4 FRIADENT® MP Cover Screw2 46 – 1430 46 – 1440 46 – 1450 46 – 1460 D 3.4 D 3.8 D 4.5 D 5.5 Impressions Impressions – Sets order no. Article FRIADENT® MP Lab Set Pickup Impression Content: MP PickUp Impression Coping, MP PickUp Guide Pin, MP Analog 46 – 8230 46 – 8240 46 – 8250 46 – 8260 D 3.4 D 3.8 D 4.5 D 5.5 FRIADENT® Impression Coping n For transferring the abutment position of to the master model n Available for PickUp (open tray) and transfer technique n The pre-mounted MP Abutment remains in the implant when making impressions FRIADENT® MP Lab Set Transfer Impression Content: MP Transfer Impression Coping, MP Analog 46 – 8130 46 – 8140 46 – 8150 46 – 8160 D 3.4 D 3.8 D 4.5 D 5.5 Impressions – Single Components Article FRIADENT® MP Pickup Impression Coping2 46 – 1630 46 – 1640 46 – 1650 46 – 1660 D 3.4 D 3.8 D 4.5 D 5.5 INSTRuMENTS Fixation of MP Pickup Guide Pin: FRIADENT® Hex Driver 1.22 mm (page 40) Placement of MP Transfer Impression Coping: FRIADENT® Hex Driver 0.9 mm (page 40) FRIADENT® MP Transfer Impression Coping2 46 – 1635 46 – 1645 46 – 1655 46 – 1665 D 3.4 D 3.8 D 4.5 D 5.5 46 – 1615 FRIADENT® MP Pickup Guide Pin4 order no. Article Implant Analog FRIADENT® MP Analog5 46 – 4030 46 – 4040 46 – 4050 46 – 4060 D 3.4 D 3.8 D 4.5 D 5.5 FRIADENT® MP Analog Included in delivery of the MP Lab Sets Impression n Is forwarded to the lab with the impression n 33 PRoSTHETICS order no. Prosthetic Components “Multi-Purpose” FABRICATION OF THE SUPRASTRUCTURE ON GINGIVA LEVEL Prosthetics/Lab: Bridges Bridges – Sets order no. FRIADENT® MP Lab Sets Bridge n For simple and accurate fabrication of bridges with cast-to or, more economically, with castable waxing sleeve n Can also be used to mill customized bar constructions Article FRIADENT® MP Lab Set Bridge with Castable Waxing Sleeve Content: Castable Waxing Sleeve, MP Screw for Waxing Sleeve 46 – 9530 46 – 9540 46 – 9550 46 – 9560 D 3.4 D 3.8 D 4.5 D 5.5 FRIADENT® MP Lab Set Bridge with Cast-to Waxing Sleeve Content: Cast-to Waxing Sleeve, MP Screw for Waxing Sleeve 46 – 9930 46 – 9940 46 – 9950 46 – 9960 D 3.4 D 3.8 D 4.5 D 5.5 FRIADENT® PassivFit Set 45 – 4830 45 – 4840 45 – 4850 45 – 4860 34 D 3.4 D 3.8 D 4.5 D 5.5 Bridges – Single Components order no. Article FRIADENT® Castable Waxing Sleeve21 45 – 4330 45 – 4340 45 – 4350 45 – 4360 D 3.4 D 3.8 D 4.5 D 5.5 FRIADENT® Cast-to Waxing Sleeve20/8 45 – 4630 45 – 4640 45 – 4650 45 – 4660 46 – 4300 D 3.4 D 3.8 D 4.5 D 5.5 FRIADENT® MP Screw for Castable Waxing Sleeve4 D 3.4 – D 5.5 Castable Waxing Sleeve: Prior to bridge delivery, the contact surface between crown and abutment and the screw and screw seat are smoothed using the FRIADENT® Finishers (page 41) Cast-to Waxing Sleeve: Smoothing with finishers is not necessary. INSTRuMENTS Placement of MP Screw for Waxing Sleeve: FRIADENT® Hex-Driver 1.22 mm (page 40) Soldering Analogs Article 45 – 4102 FRIADENT® Lab Set Soldering Analog for Bridge FRIADENT® Soldering Analog, universal and Soldering Screw for Bridge D 3.4 – D 5.5 45 – 4103 FRIADENT® Soldering Analog6, universal D 3.4 – D 5.5 45 – 4207 FRIADENT® Soldering Screw for Bridge4 D 3.4 – D 5.5 FRIADENT® Soldering Analog n For securing the framework in the soldering base PRoSTHETICS order no. 35 Prosthetic Components “Multi-Purpose” FABRICATION OF THE SUPRASTRUCTURE ON GINGIVA LEVEL Prosthetics/Lab: Bars Bars – Sets order no. FRIADENT® MP Lab Sets Bar n For fixing overdentures by bar construction n Simple and standardized procedure with pre-fabricated round bars (see single components) Customized milled bars are fabricated with castable crown bases (page 34/35). Article FRIADENT® MP Lab Set Gold Bar Coping Content: Gold Bar Coping, MP Coping Screw 46 – 9630 46 – 9640 46 – 9650 46 – 9660 D 3.4 D 3.8 D 4.5 D 5.5 FRIADENT® MP Lab Set Titanium Bar Coping Content: Titanium Bar Coping, MP Coping Screw 46 – 9637 46 – 9647 46 – 9657 46 – 9667 D 3.4 D 3.8 D 4.5 D 5.5 FRIADENT® MP Lab Set Castable Bar Coping Content: Castable Bar Coping, MP Coping Screw 46 – 9638 46 – 9648 46 – 9658 46 – 9668 36 D 3.4 D 3.8 D 4.5 D 5.5 Bars – Single Components order no. Article FRIADENT® Gold Bar Coping9 (without screw) 45 – 4230 45 – 4240 45 – 4250 45 – 4260 D 3.4 D 3.8 D 4.5 D 5.5 FRIADENT® Bar Coping Gold alloy for soldering technique n Titanium for laser welding n Cast-to for customized waxing n FRIADENT® Titanium Bar Coping2 (without screw) 45 – 4231 45 – 4241 45 – 4251 45 – 4261 D 3.4 D 3.8 D 4.5 D 5.5 FRIADENT® Castable Bar Coping21 (without screw) D 3.4 D 3.8 D 4.5 D 5.5 46 – 4200 FRIADENT® MP Coping Screw4 D 3.4 – D 5.5 45 – 4210 FRIADENT® Gold Bar round9 50 mm length 45 – 4212 FRIADENT® Titanium Bar round2 50 mm length 45 – 4215 FRIADENT® Gold Bar Clip9 50 mm length INSTRuMENTS Placement of MP Coping Screw: FRIADENT® Hex Driver 1.22 mm (page 40) PRoSTHETICS 45 – 4530 45 – 4540 45 – 4550 45 – 4560 Activating the Bar Clip: FRIADENT® Bar Clip Activator (page 41) Soldering Analogs order no. Article 45 – 4101 FRIADENT® Lab Set Soldering Analog for Bar FRIADENT® Soldering Analog, universal and Soldering Screw for Bar D 3.4 – D 5.5 45 – 4103 FRIADENT® Soldering Analog6 universal D 3.4 – D 5.5 45 – 4206 FRIADENT® Soldering Screw for Bar4 D 3.4 – D 5.5 FRIADENT® Soldering Analog n For securing the framework in the soldering base 37 Prosthetic Instruments Instrument Sets order no. Article 46 – 7000 FRIADENT® Prosthetic Set Mini The Prosthetic Set Mini includes all instruments required for the prosthetic delivery of implant restorations (“Esthetic” protocol). Content: FRIADENT® Ratchet Ratchet Hex Driver 0.9 mm/short Ratchet Hex Driver 1.22 mm/short 45 – 8111 FRIALIT® Basic Set Prosthetics The set includes all clinical instruments necessary for impression making and prosthetics. The instruments are supplied in the FRIALIT® Prosthetic Tray. Content: FRIADENT® Ratchet Handpiece Hex Driver 0.9 mm Handpiece Hex Driver 1.22 mm Ratchet Hex Driver 0.9 mm/short Ratchet Hex Driver 1.22 mm/short Ratchet Hex Driver 1.22 mm/long Ratchet Slot Screwdriver 2.0 mm/long Seating Instrument for Trasfer Coping and MH-6 Abutment/A 0 Seating Instrument for Attachment Insert and MP Insert Handpiece Seating Instrument for MP Insert Screw Handpiece Seating Instrument for MP Insert Screw 48 – 0030 38 FRIALIT® Prosthetic-Tray (empty) Instruments for uncovery order no. Article FRIADENT® Tissue Punch6 D 3.4 D 3.8 D 4.5 D 5.5 D 6.5 45 – 5338 45 – 5348 45 – 5358 45 – 5368 45 – 5378 FRIALIT® BoneProfiler6 D 3.4 D 3.8 D 4.5 D 5.5 D 6.5 45 – 5300 FRIALIT® Guide Pin for BoneProfiler 45 – 5550 FRIADENT® Soft Tissue Gauge6 FRIALIT® BoneProfiler n For removal of excessive bone on top of the implant cover screw at the stage of uncovery n Design similar to that of the gingiva former PRoSTHETICS 45 – 5666 45 – 5660 45 – 5661 45 – 5662 45 – 5663 39 Prosthetic Instruments Single Instruments order no. Article 45 – 5709 FRIADENT® Ratchet6 without inserts FRIADENT® Ratchet Hex Driver6 with torque limit 45 – 5732 45 – 5733 45 – 5734 45 – 5736 Width 0.9 mm/14 Ncm/short Width 0.9 mm/14 Ncm/long Width 1.22 mm/24 Ncm/short Width 1.22 mm/24 Ncm/long FRIADENT® Ratchet Slot Screwdriver6 with torque limit 45 – 5714 45 – 5722 Blade width 2.0 mm/14 Ncm/short Blade width 2.0 mm/14 Ncm/long FRIADENT® Handpiece HexDriver6 46 – 5710 46 – 5720 46 – 5711 46 – 5721 Width 0.9 mm/short Width 0.9 mm/long Width 1.22 mm/short Width 1.22 mm/long FRIADENT® Handpiece Slot Screwdriver6 46 – 5712 46 – 5722 Blade width 2.0 mm/short Blade width 2.0 mm/long This handle fits all handpiece drivers. 46 – 5750 FRIADENT® Handle for Handpiece Hex Driver6 The 0.9 mm FRIADENT® Hex Driver without torque limit is recommended for regions with limited access. 45 – 5650 FRIADENT® Hex Driver6 without torque limit, width 0.9 mm 45 – 5618 Mounting device for Hex Driver 45 – 5750 FRIADENT® CeraBase Tool Set Content: Medium Diamond Drill, Fine Diamond Drill, Rubber Polishing Wheel 45 – 5733 FRIADENT® CeraBase Medium Diamond Drill 45 – 5755 FRIADENT® CeraBase Fine Diamond Drill 45 – 5758 FRIADENT® CeraBase Rubber Polishing Wheels (5 pieces) 40 Single Instruments order no. Article 45 – 5605 FRIADENT® Seating Instrument2 for Transfer Coping 45 – 5617 FRIADENT® Seating Instrument2 for Attachment Insert and MP Insert 46 – 5610 FRIADENT® Ratchet Seating Instrument6 for MP Insert Screw with torque limit 46 – 5615 FRIADENT® Handpiece Seating Instrument6 for MP insert screw for contra-angle handpie- 45 – 5621 FRIADENT® Activator6 for Ball and Socket Attachment 45 – 5622 FRIADENT® Deactivator6 for Ball and Socket Attachment 45 – 3340 LoCAToR® Core Tool49 3-piece 45 – 3344 FRIADENT® LoCAToR® Insert for Prosthetic Ratchet6 45 – 3345 LoCAToR® Angle Measurement Guide51 45 – 5623 FRIADENT® Bar Clip Activator6 45 – 5702 FRIADENT® Finisher6/10 for Horizontal Screw Set PRoSTHETICS ce FRIADENT® Finisher6/10 for Abutment Seat for Screw-retained Suprastructures 45 – 5705 45 – 5707 45 – 5700 45 – 5709 45 – 5623 D 3.4 – D 4.5 D 5.5 FRIADENT® Finisher6/10 for Screw Head Seat for Screw-retained Suprastructures 45 – 5621 45 – 5622 41 Presentation Material Demo-Modelle order no. Article 45 – 9981 FRIADENT® Acrylic Model Maxilla without prosthetics (ANKYLOS®, XiVE®, FRIALIT®) 45 – 9982 FRIADENT® Acrylic Model Maxilla with prosthetics (ANKYLOS®, XiVE®, FRIALIT®) Patient Information Material order no. Article 5 – 002032 DENTSPLy Implants Waiting room brochure 5 – 402001 FRIALIT® Indication poster 5 – 001033 DENTSPLy Implants Dental Implant Pass CD-RoMs for Presentations 42 order no. Article 66 – 4050 FRIALIT® Picture CD 66 – 1036 DENTSPLy Implants Picture CD 66 – 1037 CERCoN® Picture CD 66 – 1038 Picture CD for Internet, all systems 66 – 1039 FRIADENT® plus Picture CD Materials Metals Type Index Composition Titanium Titanium Titanium Titanium Aluminium Ti grade 1 Ti grade 2 Ti grade 4 Ti6Al4V grade 5 AlMg3 Stainless steel Stainless steel Stainless steel Brass Cast-to alloy* Gold alloy** Hard metal Polyethylen/Aluminium Polyamid/Polyethylen/Stainless steel/Plastics Polyamid/Polyethylen/Stainless steel/Plastics Aluminium Brass/Polyoxymethylene Brass/Polysulfon 1 2 3 4 5 6 49 51 7 8 9 10 42 43 44 45 48 50 Surgical Steel 316L SS SS/303 SE 316L SS CuZn Au: 60%, Pt: 19%, Pd: 20%, Ir: 1% Au: 68,6%, Pt: 2,4%, Pd: 4%, Ag: 11,8%, Cu: 10,6%, Ir: 0,1%, Zn: 2,5% K 40 LDPE/6061 T6 Al Nylon/LDPE/Ti6AI4V/Silicone Rubber Nylon/LDPE/303 SE SS/Silicone Rubber 6061 T6 Aluminum MS-002, DELRIN, 1/4" MS-013-1 POLYSULFONE (3/8") *TEC 11.9 x 10-6 K-1, pre-heating temperature < 850°C, cast temperature < 1450°C; ** melting interval from 880 – 940°C Plastics Polyoxymethylene (POM) Index Polypropylene Polyamid Polyethylen/Aluminium Polyamid/Polyethylen/Stainless steel/Plastics Polyamid/Polyethylen/Stainless steel/Plastics Polyethylen Brass/Polyoxymethylene Brass/Polysulfon Polymethylmethacrylate (PMMA) Polystyrene Polytetrafluourethylene Polyetheretherketone (PEEK) Polyetherimide Silicone Silicone Polycarbonate 20 21 22 23 24 25 26 47 27 28 41 42 43 44 46 48 50 Composition Silicone Rubber Zytel 101l Nylon LDPE/6061 T6 Al Nylon/LDPE/Ti6AI4V/Silicone Rubber Nylon/LDPE/303 SE SS/Silicone Rubber LDPE MS-002, DELRIN, 1/4" MS-013-1 POLYSULFONE (3/8") Ceramics Type Index Composition Aluminium oxide 30 Al2O3 Hydroxyapatite 31 Ca5(PO4 )3OH Zirconium dioxide 32 ZrO2 43 presentation MATERIAL Type Order no. 6-402053/006 Some products may not be available in all countries. Please contact your DENTSPLY Implants representative to obtain up to date information on the product range and on availability. Manufacturer: DENTSPLY Implants Manufacturing GmbH · P.O. Box 71 01 11 · 68221 Mannheim/Germany Phone +49 621 4302-000 · Fax +49 621 4302-001 · e-mail: [email protected] Manufacturer of XiVE® Locator®: ZEST ANCHORS, LLC. · 2061 Wineridge Place · Escondido, CA 92029/USA EC Representative: Wellkang Ltd. · 29 Harley St. W1G 9QR London/ U.K. www.dentsplyimplants.com 0613/0.5/SB Manufacturer of FRIOS® Handpieces and FRIOS® Unit S/i: W&H Dentalwerk Bürmoos GmbH · 5111 Bürmoos/Austria
Similar documents
Product Catalog - DENTSPLY Implants
■ Simple operating concept specially designed for implant surgery ■ Powerful, quiet running surgical motor ■ User-oriented program sequence with thread-tapping function actuated by pushbutton
More informationProduct Catalog
imple product identification with brandspecific design, sight window and colorcoded imprint of the implant diameter • Large seal label with details of products • Stackable, all important produc...
More informationProduct Catalog - DENTSPLY Implants
Impression taking on abutment level (MP) Prefabricated abutments • EstheticBase Abutment • CERCON® Abutment • CeraBase Abutment • AuroBase Abutment • Telescopic Abutment • MP Abu...
More informationProduct Catalog - DENTSPLY Implants
surgery and prosthetics are also sealed in blisters in branded cardboard packages.
More informationAnkylos Catalog - DENTSPLY Implants
ANKYLOS Implant Drivers n For placement of ANKYLOS C/X implants n For use with the contra-angle hand-piece (HXSS) or with the ratchet