ETOS-Profibus
Transcription
ETOS-Profibus
AC&T System Co.,Ltd. History of AC&T System 1998 - Established of AC&T System - Choose industrial Ethernet and Serial Server (ETOS) as item to be developed 1999 - 2000 - Registered with Venture’ s Business - Launched ETOS-50 to domestic markets - Attracted an Investment from SAMSUNG Capital 2001 - Launched ETOS-150 to domestic markets - Launched ETOS-1000 to domestic markets - Launched ETOS-200 to domestic markets 2002 - Got a patent for ETOS (Title : Easy Programmable Gateway System and its controlling methods) 2003 - ETOS has received the Certification as Infor-communication devices - Contraction with LGIS about O.E.M of ETOS - Contraction with Hynix (Semiconductor manufacture) to supply ETOS 2004 - Win the Prize of Sincere Economist issued by provincial governor - Launched ETOS-150D to domestic markets - Win the Prize of Commendation issued by Minister of Science and Technology Administration 2005 - 2006 - i-Fos F4/50/100/200 has received the international authentication CE - Selected as Excellent Technology Business Company 2007 - Got a patent for Switch system including VLAN (Virtual Lan) Module Board and how to initialize this system - ETOS-TS/300 has received the international authentication CE Transformed to a Corporation from personal company of AC&T System Executed industry-university cooperated project to develop the SECS and HSMS Got a patent for ETOS Joined in Profibus Association of Korea Established a Research Laboratory titled“Communication System Laboratory” Launched ETOS-100 to domestic markets Launched ETOS-DNA to domestic markets Launched ETOS-CC-Link to domestic markets Launched ETOS-Profibus to domestic markets Selected as Excellent Technology Business Company ETOS Industrial Communication Server INDEX ETOS-SERIES Introduction/ 3 Specification/ 5 ETOS-1000/ 8 ETOS-150/ 11 ETOS-100D/ 14 ETOS-CC-Link/ 17 ETOS-PD(Protocal Design)/ 23 ETOS-300/300D/ 9 ETOS-150D/ 12 ETOS-50A/ 15 ETOS-DNA-PLUS/ 18 TS-WIN/ 25 Ordering Information/ 26 Dimension/ 28 ETOS-200/ 10 ETOS-100A/ 13 ETOS-Profibus/ 16 ETOS-TS/ 22 Industrial Communication Server ETOS 2 ETOS ETOS-SERIES Introduction ETOS is industrial data communication server greatly improved for user convenience and system installing convenience with using User Defined Concepts for communicating between various devices based on serial, Ethernet, and Fieldbus in industrial area. It makes possible to communicate between all devices of industrial area with having built-in communication drives, easy user defined and powerful monitoring/debugging function. So it gives users a lot of benefits to reduce labor and time costs required to open communication. ET OS -S ERIES Fe at he r s High performance Industrial Communication Server used a 32Bit RISC CPU ETOS-SERIES Introduction Supports high reliability and performance function with using Real Time OS Enable to install optimized system at various applications with combined serial ports (offers up to 64 serial ports) Each serial port (Max up to 64 ports) can individually and simultaneously communicate with each counter device Supports wire(dedicated Modem) and wireless(CDMA/RF Modem) Supports calling and receiving function of CDMA and sending SMS function Supports various serial communicating drivers(GLOFA Cnet/Modbus/Melsec) User Defined Communication with using frame defining function(commonly serial and Ethernet) Supports Ethernet communication of 100BASE-T and 10BASE-T (IEEE802.3) Supports Ethernet network redundancy (ETOS-1000/ETOS-300D/ETOS-200/ETOS-150D/ETOS-100D) Supports redundancy of CPU and Power (ETOS-1000/ETOS-200) Offers various Ethernet communication drivers (GLOFA Enet/ModbusTCP/Melsec) Supports function of high speed link service(Possible to link with LSIS Ethernet) Supports DHCP (when using xDSL) Supports Data backup with using Battery circuits Supports data saving, calculating, processing function with using abundant memory Offers various command(such as data translation, calculation, saving, and copying etc) Supports abundant communication trouble checking function(SUM/XOR/OR/CRC/LRC ETC) Functions monitoring and controlling of Analog / Digital input/output(ETOS-DNA-PLUS) Functions monitoring memory, and editing frame and process with using ETOS-PD Real time frame monitoring function => communicating status diagnosis and observing function Abundant Self-diagnosing Functions(LED Display, Log Data) 3 ETOS ETOS ETOS-SERIES Introduction Don’t miss your connection : AC&T System offers you flexible, highly available and future-safe network technology solutions in the usual high quality from simple switches through field bus systems to high performance Ethernet componets. Using ETOS, it is possible to monitor and communicate between various controllers. Integration of different type of communications Ethernet / Serial(RS232 / RS422 / RS485) /SECS-I / HSMS/ Profibus /CC-Link/ Fnet Network integration of unit equipments Integration of communicating device of equipment and Ethernet Remote control and managing with using Dedicated line and Internet line ETOS-SERIES Introduction KT-Dedicated line, CDMA wireless, CDMA SMS, DHCP Changeable IP Installation of Integrated supervising and controlling system It is possible to monitor up to max 64’ s remote equipments, and possible to achieve the server role of gathered data’s saving and converting. SECS communication between semiconductor equipments Combined and serial communication between SECS-I and HSMS Integrated communication between serial and Ethernet Communication between all serial devices, and communication between serial device and Ethernet device Communication with Open Fieldbus devices ETOS is possible to link with Profibus-DP’s devices and CC-Link’ s devices Communication with Dedicated network Possible to link with LSIS’s Fnet and I-NET ETOS 4 ETOS ETOS Specification Environment Specification Related standard Specification Items Operating Temperature -10℃ ~ +60℃ Storage Temperature -25℃ ~ +70℃ Operating Humidity 5~95%RH, Non-condensing Storage Humidity 5~95%RH, Non-condensing For discontinuous vibration Vibration Frequency Acceleration Amplitude 10≤f�57Hz - 0.075mm 57≤f≤150Hz 9.8㎨ (1G) - The Number of times IEC 1131-2 For continuous vibration Acceleration Amplitude 10≤f�57Hz - 0.035mm 57≤f≤150Hz 4.8㎨ (0.5G) - Frequency Each 10 times in X,Y,X directions ETOS Specification * Max. Impact acceleration : 147㎨ (15G) * Authorized time : 11ms * Pulse waveform : Sine Haft-wave Pulse (Each 3 times in X,Y,X directions) Impact Square wave Impulse Noise ± 1500V Static electric discharging Voltage : 4Kv(contact discharging) Radiation field noise Noise Test Spec. referred within AC&T IEC 1131-2, IEC 801-2 IEC 1131-2, IEC 801-3 27~500 MHz, 10V/㎖ Classi- Power Fast transient/burst fication Module noise Voltage Digital I/O Digital I/O(24V Above) (24V Above) 2kV 1kV Ambient conditions No corrosive gas and dust Pollution level Below 2 Cooling type Natural air cooling(Fan-less) Analog I/O Network Interface IEC 1131-2, IEC 801-4 0.25kV Power Specification Model 5 ETOS-CC-LInk ETOS-DNA ETOS-100 ETOS-300 ETOS-50 ETOS-200 ETOS-Profibus -PLUS ETOS-150 ETOS-300D Input Source DC24V Capacity 5V/500mA AC 110V/220V(50/60Hz), Free Voltage 5V/4A 5V/1A 5V/2.5A 5V/7A ETOS-TS AC 90~260V, 50/60Hz 5V/3A ETOS-1000 AC110V/220V, select 5V/15A 12V/3A ETOS ETOS ETOS Specification Performance Specification Model ETOS-DNA-PLUS Classification ETOS-Profibus ETOS-CC-Link ETOS-50A ETOS-100A User Memory 256K,1M,2M,4MBytes 64KBytes 64KBytes 64KBytes 256KBytes Backup Memory Supports - - - Supports Program Memory 1.0MBytes 1.0MBytes 1.0MBytes 1.0MBytes 1.0MBytes Log Memory 256KBytes 256KBytes 256KBytes 256KBytes 256KBytes Ethernet Ports(Max.) 1 1 1 1 1 Serial Ports(Max.) 4 2 2 2 4 I/O 64channel - - - - WatchDog Supports - - - Supports RTC Supports - - - Supports Power - - - - - CPU - - - - - Ethernet - - - - - ETOS-150 ETOS-100D ETOS-150D ETOS-200 ETOS-1000 256KBytes 512KBytes 2.0MBytes 256KBytes 512KBytes Redundancy Model Cla ssification User Memory Backup Memory Supports Supports Supports Supports Supports Program Memory 1.0MBytes 2.0MBytes 1.0MBytes 2.0MBytes 2.0MBytes Log Memory 256KBytes 512KBytes 256KBytes 512KBytes 512KBytes Ethernet Ports(Max.) 1 2 2 2 2 Serial Ports(Max.) 4 4 4 16 64 I/O - - - - - WatchDog Supports Supports Supports - - RTC Supports Supports Supports Supports Supports Power - - - - Supports CPU - - - Supports Supports Ethernet - Supports Supports Supports Supports Redundanc y ETOS Specification Performance Specification Performance Specification Model ETOS-TS ETOS-300 ETOS-300D User Memory 8.0MBytes 8.0MBytes - Backup Memory Supports Supports - Classificati on Program Memory 1.0MBytes 1.0MBytes - Log Memory 1024KBytes 1024KBytes 1024KBytes Ethernet Ports(Max.) 1 2 2 Serial Ports(Max.) 8/16 8/16 8/16 I/O - - - WatchDog Supports Supports Supports RTC Redundancy Supports Supports Supports Power Supports Supports Supports CPU - - - Ethernet - Supports Supports * The Specification of ETOS can be changed for performance improving without a previous notice ETOS 6 ETOS ETOS Specification Ethernet communication Spec Specifications Classifications Speed 10Mbps / 100Mbps Transmitting Method BaseBand Max. Segment Distance 100M(Node - Hub간 길이) Max. Protocol Data Size 1500 Byte Protocol TCP/IP, UDP/IP, DHCP Media Access CSMA/CD, IEEE 802.3 D e d i c a t e d C o m m u n i c a t i o n D r i v e r s [*1][*2] LSIS’ s Enet Dedicated Protocol,Modbus TCP,Melsec-A/Q Series,POSFA High Speed Link LSIS’s Enet Dedicated Protocol Should be set to Ethernet V2.0 when communicates with Modbus TCP and Melsec Driver [*1] [*2] LSIS Enet and ModbusTCP support both Master and Slave service, but Melsec and POSFA support only Master service ETOS Specification Serial communication Spec Specifications Classifications Data Bit 7 or 8 Bit Stop Bit 1 or 2 Bit Start Bit 1 Bit Parity Bit Even/Odd/None/Space/Mark Synchronous method Asynchronous Speed(BPS) 300/600/1200/1800/2400/3600/4800/7200 9600/19200/38400/57600/64000/115200 DCE Modem to be used Dedicated Modem, CDMA Modem ,Dial-UP Modem, Null Modem Distance RS-232C : 15M / RS-422 : 500M Dedicated Communication Drivers [*1] [*1] LSIS Cnet, Modbus-ASII/RTU, Melsec-A/Q LSIS Cnet and Modbus-ASII/RTU support Master and Slave service, but Melsec supports only Master service Fieldbus Communication Spec Protocol Profibus-DP CC-Link 7 Protocol Models ETOS-OPT-DPM ETOS-DPS ETOS-CC-Link Specifications Profibus-DP Master Profibus-DP Slave EN 50170/DIN 19245 Compatible with CC-Link v2.0 Fnet ETOS-OPT-Fnet Compatible with LSIS Fnet inet GMPC-Master Compatible with LSIS Fnet ETOS ETOS-1000 ETOS-1000 Be s t S o lut i o n f o r C e nt r ali ze d S C A DA and C ELL co nt r o l s y s t e m ETOS-1000 Feathers Ensures reliability with supporting redundancy of CPU and Power Supports network redundancy with dual Ethernet Connects up to 64 serial(RS232/RS422/RS485) ports Possible to extend RS232/RS422 channel with 4 or 8 units Gives more convenience to Users to install large system integrating with abundant user memory(512kbytes)(TM Masterr/SCADA System) ETOE ST-O SS ER1IE 0S 00개요 Modules Classification Specification Model Redundant CPU ETOS-1000-RCP Redundant CPU, Ethernet 1 port Single CPU ETOS-1000-SCP Single CPU, Ethernet 1 port Serial ETOS-1000-S40 RS232C 4 Ports Serial ETOS-1000-S80 RS232C 8 Ports Serial ETOS-1000-S04 RS422/RS485 4 Ports Serial ETOS-1000-S08 RS422/RS485 8 Ports Serial(Mixed Type) ETOS-1000-S44 RS232 4 Ports /RS422 4 Ports Redundant Power ETOS-1000-PSR Redundant Power(AC110V/220V, 50/60Hz) Single Power ETOS-1000-PSS Power(AC110V/220V, 50/60Hz) Housing ETOS-1000-BAS Base Module + Case Dummy Cover ETOS-1000-NUL Empty Slot Cover ETOS-1000 Application Systems http://www.acnt.co.kr 8 ETOS-300/300D S uppo r t s S EC S -I/ H S MS t hat i s s e m i co nduct o r e qui pm e nt s s t andar d pr o t o co l as Dat a C o m m uni cat i o n S e r ve r f o r m i ddle s i ze d s y s t e m i nt e gr at i o n ETOS-DNA ETOS-300/300D ETOS-300/300D Feathers Network integration of standard network, serial and Ethernet Editing functions of serial and Ethernet frame Supports abundant user memory (8Mbytes) Offers Ethernet communication redundancy (Supports only ETOS-300D) redundant Power(optional) Supports SECS-I/HSMS that is semiconductor equipments standard protocol EE TT OO SS -S3 E0R0IE /3 S00 개D요 Modules Classification Model Main ETOS-300-FO Ethernet 1 Port+RS232 16Ports+Single Power Main ETOS-300-OF Ethernet 1 Port+RS422 16Ports+Single Power Main ETOS-300-FOR Ethernet 1 Port+RS232 16Ports+Redundant Power Main ETOS-300-OFR Ethernet 1 Port+R422 16Ports+Redundant Power Main ETOS-300D-FO Ethernet 2 Ports+RS232 16Ports+Single Power Main ETOS-300D-OF Ethernet 2 Ports+RS422 16Ports+Single Power Main ETOS-300D-FOF Ethernet 2 Ports+RS232 16Ports+Redundant Power Main ETOS-300D-OFR Ethernet 2 Ports+R422 16Ports+Redundant Power Main ETOS-316D-SGATE Ethernet 2 Ports+RS232 16Ports, SECS-I<->HSMS Bridge Main ETOS-316D-SECS Ethernet 2 Ports+RS232 16Ports, HSMS ETOS-300/300D Application System 9 AC&T System Specification ETOS-200 S uppo r t s S EC S -I/ H S MS t hat i s s e m i co nduct o r e qui pm e nt s s t andar d pr o t o co l and T M Mas t e r f o r m e ddle s i ze d s y s t e m i nt e gr at i o n ETOS-200 ETOS-200 Feathers Supports SECS-I/HSMS that is semiconductor equipments standard protocol Supports Ethernet and CPU redundancy Supports up to 16 serial ports (RS-232/422/485) Supports abundant user memory(512k byte) Offers merits to install of middle sized network integration Modules Classification Specification Model ETOS-200-RCP Redundant CPU(Ethernet 2 Ports)+Base+Housing+Power Single CPU ETOS-200-SCP Single CPU(Ethernet 1 Ports)+Base+Housing+Power Serial ETOS-200-S40 RS232 4 Ports Serial ETOS-200-S80 RS232 8 Ports Serial ETOS-200-S04 RS422 / RS485 4 Ports Serial ETOS-200-S08 RS422 / RS485 8 Ports Serial(Mixed Type) ETOS-200-S44 RS232 4 Ports and RS422 4 Ports SECS/HSMS ETOS-200-HSMS Ethernet 1 Port+RS232 8 Ports with HSMS SECS/HSMS ETOS-200-Sgate Ethernet 2 Ports+RS232 8 Ports with SECS-I<->HSMS Bridge Redundant Power ETOS-200-PSR ETOS-200-HSMS Base + Redundant 100/220V, 이더넷 1포트 + Power(AC RS232 8포트/ HSMS 50/60Hz) 통신 ETOS-200-PSS Base + Single Power(AC 100/220V, 50/60Hz) Single Power ETOS-200 Redundant CPU ETOS-200 Application System Control and Monitoring Center CDMA Base Station CDMA Modem Remote-Site-A CDMA Modem Dedicated Line Modem Dedicated Line Modem KT Dedicated Line Dedicated Line Modem Dedicated Line Modem Remote-Site-B Dedicated Line Modem Remote-Site-C Dedicated Line Modem Electric Power Meter http://www.acnt.co.kr 10 ETOS-150 ETOS-150 Indus t r i al C o m m uni cat i o n S e r ve r f o r S EC S t hat i s s e m i co nduct o r e qui pm e nt s t andar d co m m uni cat i o n pr o t o co l ETOS-150 Feathers Supports SECS-I/HSMS that is semiconductor equipments standard protocol Supports SECI-I , SECS-II and HSMS regardless of the controller (PC,PLC, or Dedicated controller) of equipment Integration of semiconductors and an upper managing system regardless of supporting the SECS protocol or not Modules Classification Model Main ETOS-150-HSMS Ethernet 1 Port+RS232 2 Ports / HSMS Main ETOS-150-Sgate Ethernet 1 Port+RS232 2 Ports / SECS <-> HSMS Bridge Specification ETOS-150 * Possible to add serial option 2 ports of ETOS-100 if want to extend serial ports Procedures of using of EOTS-150 1. Convert general RS232 to SECS-I or HSMS - Convert any data of equipment and controller (PLC, Dedicated controller) not to support SECS into SECS standard protocol - Possible to make the semiconductor standard protocol quickly 2. Convert SECS-I to HSMS(Ethernet) - Possible to install the HSMS quickly on equipment to support only SECS-I - Supports HSMS protocol by simple parameter setting - Supports communication speed range of 9600bps to 115200bps on SECS-I - Able to use host and equipment on HSMS ETOS-150 Application System 11 AC&T System ETOS-150D Intelligent Industrial Communication Server to support redundancy of Ethernet, and to support Semiconductor equipment ’s standard communication Protocol (SECS/HSMS) ETOS-150D ETOS-150D Feathers Supports network(Ethernet) redundancy (Dual MAC) Able to separate factory network from office network because redundant Ethernet 2 ports are simultaneously working (Protect to occur communication trouble of FA network by traffic congestion of office PC Supports SECS-I/HSMS that is semiconductor equipments standard protocol Supports SECI-I, SECS-II and HSMS regardless of the controller (PC,PLC, or Dedicated controller) of equipment Integration of semiconductors and an upper managing system regardless of supporting Modules Classification Model Specification Main ETOS-150D-HSMS Ethernet 2 Ports(Redundant)+RS232 2 Ports/HSMS * Possible to add serial option 2 ports of ETOS-100 if want to extend serial ports ETOS-150D the SECS protocol or not ETOS-150D Application System http://www.acnt.co.kr 12 ETOS-100A Intelligent Industrial Communication Server to be used to integrate the middle and small sized network, and to integrate local multi-devices ETOS-100A ETOS-100A Feathers Able to simultaneously connect up to 4 serial ports on Ethernet 1 port Operate independently 4 serial ports (able to connect simultaneously up to 4 serial ports) Support simultaneously Client and Server function of Ethernet Convert protocols between Ethernet and Serial Supports open Fieldbus - Profibus-DP Master - LSIS Fnet ETOS-100A Modules Classification Model ETOS-100A-S20 RS232 2 Ports Main ETOS-100A-S02 RS422 2 Ports Main ETOS-100A-S11 RS232 1 Port , RS422 1 Port Main ETOS-100A-E20 Ethernet 1 Port,RS232 2 Ports Main ETOS-100A-E02 Ethernet 1 Port,RS422 2 Ports Main ETOS-100A-E11 Ethernet 1 Port,RS232 1 Ports , RS422 1 Port Serial Option ETOS-OPT-232 RS232 2 Ports Serial Option ETOS-OPT-422 RS422 2 Ports Fieldbus Option ETOS-OPT-Fnet LSIS Fnet 필드버스 옵션 ETOS-OPT-DPM Profibus-DP master ETOS-100A Application System 13 AC&T System Specification Main ETOS-100D ETOS-100D Intelligent Industrial Communication Server to integrate local networks based on Ethernet redundancy ETOS-100D Feathers Supports network(Ethernet) redundancy (Dual MAC) Able to simultaneously connect up to 4 serial ports on Ethernet 1 port Operate independently 4 serial ports channels (able to connect simultaneously up to 4 serial ports) Support simultaneously Client and Server function of Ethernet Convert protocols between Ethernet and Serial Supports open Fieldbus -Profibus-DP Master -LSIS Fnet Classification Model Specification Main ETOS-100D-E20 Ethernet 2 Ports,RS232 2 Ports Main ETOS-100D-E02 Ethernet 2 Ports,RS422 2 Ports Main ETOS-100D-E11 Ethernet 2 Ports,RS232 1 Ports , RS422 1 Port Serial Option ETOS-OPT-232 RS232 2 Ports Serial Option ETOS-OPT-422 RS422 2 Ports Fieldbus Option ETOS-OPT-Fnet GLOFA Fnet Fieldbus Option ETOS-OPT-DPM Profibus-DP master ETOS-100D Modules ETOS-100D Application System http://www.acnt.co.kr 14 ETOS-50A ETOS-50A Communications between multi-devices on small and simple network Communications using Dedicated line and DHCP on remote sites ETOS-50A Feathers Able to simultaneously connect 1 serial port on Ethernet 1 port Converts protocols of multi-devices with 2 serial ports Suits to protocol converting of united machinery equipment Supports simultaneously Client and Server function of Ethernet Converts protocols between Ethernet and Serial Modules ETOS-50A Classification [*1] Model Main ETOS-50A-S20 RS232 2 Ports Main ETOS-50A-S02 RS422 2 Ports Main ETOS-50A-S11[*1] RS422 1 Port(COM1) , RS232 1 Port(COM2) Main ETOS-50A-E10 Ethernet 1 Port,RS232 1 Port Main ETOS-50A-E01 Ethernet 1 Port,RS422 1 Port Main ETOS-50A-Sgate Ethernet 1 Port,RS232 1 Port(Convert SECS-I to HSMS) On Serial 2-Ports, Com1 is fixed to RS422, and Com2 is fixed to RS232 ETOS-50A Application System 15 Specification AC&T System ETOS-Profibus ETOS-Profibus Useful to connecting serial device on profibus-DP network ETOS-Profibus Feathers Supports completely Profibus-DP Slave function Supports simultaneously Client and Server on serial communication Converts protocols between Profibus and Serial Connecting devices of different type with serial frame defining function Serial Communication Drivers(GLOFA, Modbus, Melsec) Profibus-DP Specifications Classification Specification Protocol Profibus-DP Slave, EN 50170/ DIN19245 Interface RS-485(Electrically isolated) ETOS-Profibus 9600bps~12Mbps/ Auto Baudrate Speed 1.2Km~100m/Adjust according to Baudrate Distance Max. stations 32 Station/ Segment I/O Data Size Input 64 Byte/Output 64 Byte Plug Connector 9 pin D-sub Cable Two wire shielded twisted pair cable Terminal Resistor 220ohm,1/2W (Connect to each A-B line) Modules Classification Model Specification Main ETOS-DPS-S02 Profibus-DP Slave ,RS422 2 Ports Main ETOS-DPS-S20 Profibus-DP Slave ,RS232 2 Ports ETOS-Profibus Application System http://www.acnt.co.kr 16 ETOS-CC-Link ETOS-CC-Link Useful to connect serial device on CC-Link network ETOS-CC-LINK Feathers Supports completely CC-Link V2.0 Slave function Supports simultaneously Client and Server on serial communication Converts protocols between CC-link and Serial Converts protocols between CC-link and Ethernet Function to connect devices of different type with serial frame defining function Ethernet and serial Communication Drivers(GLOFA, Modbus, Melsec) CC-Link Specifications Specification Classification ETOS-CC-Link Protocol Compatible with CC-Link Slave V2.0 Interface RS-485(Electric)/Bus Topology 10M/5M/2.5M/625K/156kbps Speed Broadcast Polling Communication Type x1 /x2 /x4 /x8 Extending Cyclic setting Max. stations to be able to possess Max. number of station to be connect to Cable 4 Stations(Station no is up to 64) Remote Device stations are up to 42 CC-link dedicate Cable(Shielded and twisted 3 pairs Cable) 110ohm,1/2W (Connect to each DA-DB line) Terminal resistor Modules Classification Model ETOS-CCS-E00 CC-LInk Slave, Ethernet Main ETOS-CCS-S02 CC-LInk Slave, RS422 2 ports Main ETOS-CCS-S20 CC-LInk Slave, RS232 2 ports ETOS-CC-Link Application System 17 AC&T System Specification Main ETOS-DNA-PLUS Best optimized wire and wireless controller to add function of controlling and monitoring on powerful communication capability ETOS-DNA-PLUS ETOS-DNA-PLUS Feathers Offers Ethernet 1 port(100BaseT/DHCP/Communication Drivers) Up to 4 serial communication ports(RS232 / RS422) Supports wire(Dedicated Modem) and wireless(CDMA/RF Modem) Function to be sending SMS with CDMA Modem(Event Alarm function) Various I/O formations(Relay and TR output/ Analog and DC input) Possible to use as redundant RTU that is consisted of wire and wireless way Controller for controlling and monitoring of unmanned remote sites ETOS-DNA PLUS Modules Classification Main (Classify by port) Option (Classify by I/O) [*1] Model Specification ETOS-DNA-PLUS-S20 Serial (RS232) 2 Ports ETOS-DNA-PLUS-S02 Serial (RS422) 2 Ports ETOS-DNA-PLUS-S40 Serial (RS232) 4 Ports ETOS-DNA-PLUS-S04 Serial (RS422) 4 Ports ETOS-DNA-PLUS-S22 Mixed Serial RS 232 2 Ports, RS422 2 Ports ETOS-DNA-PLUS-E20 Ethernet 1 Port + RS232 2 Ports ETOS-DNA-PLUS-E02 Ethernet 1 Port + RS422 2 Ports ETOS-DNA-PLUS-E40 Ethernet 1 Port + RS233 4 Ports ETOS-DNA-PLUS-E04 Ethernet 1 Port + RS422 4 Ports ETOS-DNA-PLUS-E22 Ethernet 1 Port + RS232 2 Ports / RS422 2 Ports DNA-PLUS-OPT-RY16 Relay Output 16 Points DNA-PLUS-OPT-TR16 TR Output 16 Points DNA-PLUS-OPT-DC16 DC24V Input 16 Points DNA-PLUS-OPT-DT15 TR Output 7 Points / DC 24V Input 8 Points (for combined input and output) DNA-PLUS-OPT-DR16 Relay Output 8 Points / DC24V Input 8 Points (for combined input and output) DNA-PLUS-OPT-AD4 Analog Input 4 ch [*1] Refers Analog Specification of ETOS-DNA The methods to classify Main Model name : ETOS-DNA-PLUS- X , Y , Z - AA X : Classify Ethernet and Serial : S = Serial , E = Ethernet Y : Quantity of RS232 Ports Z : Quantity of RS422 Ports AA : User Memory Size (none, 1M, 2M, 4M) [Example] ETOS-DNA-E22 : Ethernet 1 Port, RS232 2 Ports, RS422 2 Ports, 256Kbyte user memory ETOS-DNA-E22-4M : Ethernet 1 Port, RS232 2 Ports, RS422 2 Ports, 4MByte user memory http://www.acnt.co.kr 18 ETOS-DNA-PLUS ETOS-DNA-PLUS Possible to make diverse and abundant I/O system Digital Output Specification Classification DNA-PLUS-OPT-RY16 DNA-PLUS-OPT-TR16 Input/Output Spec. Relay Output TR Ouput nput/Output Points 16 Points 16 Points Relay Isolation Photo coupler Isolation Isolation method Polarity Type Sink type(-COM) - Rated Load Voltage DC24V, AC110V/220V DC12V, DC24V Rated Load Current 5A/COM 3A/COM Response time OFF->ON 10 mSecs 2 mSecs ON->OFF 12 mSecs 2 mSecs Common method Status Display 16 Points / 1 COM 8 Points / 1 COM Display by LED Display by LED ETOS-DNA Digital Input/Output Specification Classification DC Input module Input/Output Points Input 16 Points DNA-PLUS-OPT-DT15 Mixed DC Input/TR Output 입력Input 8점/출력 7점 8Points /Output 7Points DNA-PLUS-OPT-DR16 Mixed DC Input/Relay Output 입력Input 8점/출력 8점 8 Points /Output 8 Points Isolation method Photo coupler Isolation Photo coupler Isolation Polarity Type Source/Sink (non-Polarity) - - Rated Input Voltage /Current Input DC24V/11mA Refer DC input Module Refer DC input Module On Voltage/Current Off Voltage/Current Response time 10 mSecs ON->OFF 10 mSecs Status Display AC&T System Input DC15V/6mA Input under DC5V/1mA OFF->ON Common method 19 DNA-PLUS-OPT-DC16 Input/Output Spec 8 Points / 1 com Display by LED Photo coupler Isolation - - Refer Tr Output Module Refer Relay Output Module - - Input 8 Points/ 1 COM Output 7 Points/ 1 COM Input 8 Points/ 1 COM Output 8 Points/ 1 COM Display by LED Display by LED ETOS-DNA-PLUS ETOS-DNA-PLUS Possible to make abundant Analog/Digital I/O system Analog Input Specification Classification Input Spec Number of Input Channels Input Resolution DNA-PLUS-OPT-AD4 Analog Input Voltage/Current Module 4 Channels Voltage DC -10V~+10V, -5V~+5V, 0~10V, 0~5V, 1~5V Current DC 1~20mA, 4~20mA Selecting Voltage/Current Selecting by Terminal Digital Output -16000 ~ +16000 Voltage 0.25 mV Current 1 uA Precision Rate Isolation method Internal Process Status Display ETOS-DNA Analog / Digital Isolating Input Terminal and Internal circuits by Photo coupler(Non-Isolation between channels) 10mSec / 1 Channel Average Process(Average Value Setting function), Sampling Display by LED Input / Output Wiring Diagram http://www.acnt.co.kr ETOS-DNA Max. Converting Speed ± 0.1%(Full Scale) 20 ETOS-DNA-PLUS ETOS-DNA-PLUS Possible to apply to diverse applications with combining of control and communication ETOS-DNA 21 AC&T System ETOS-TS ETOS-TS Connecting between Ethernet and serial network with simply and easily parameters setting ETOS-TS Feathers Easily connects Serial devices to Ethernet(100/10BaseT) Supports redundant Ethernet(Dual MAC) Offers diverse TCP/UDP applications Ensures excellent reliability in harsh industrial environments Supports Fail Safe Power Supply(Supports redundant Power) Modules Classification Model Specification ETOS-TS-FO Ethernet 2 Ports + RS232 16 Ports + Single Power Main ETOS-TS-OF Ethernet 2 Ports + RS422 16 Ports + Single Power Main ETOS-TS-80 Ethernet 2 Ports + RS232 8 Ports + Single Power Main ETOS-TS-08 Ethernet 2 Ports + RS422 8 Ports + Single Power Main ETOS-TS-FOR Ethernet 2 Ports + RS232 16 Ports + Redundant Power Main ETOS-TS-OFR Ethernet 2 Ports + RS422 16 Ports + Redundant Power Main ETOS-TS-80R Ethernet 2 Ports + RS232 8 Ports + Redundant Power Main ETOS-TS-08R Ethernet 2 Ports + RS422 8 Ports + Redundant Power ETOS-TS Main ETOS-TS Application System http://www.acnt.co.kr 22 ETOS-PD (Protocol Designer) Powerful Window Software Package to simply connect between all communication devices ETOS-PD ETOS-PD is a Window Software Package to program, edit and monitor of the user program of all ETOS Products. At first Users edit all process programs, basic parameters and communication type to communicate with general purpose serial devices (RS232,RS422 and RS485), open communication devices and managing Ethernet devices with using ETOS-PD, and then download the edited contents to ETOS to be working in various protocol operations ETOS-PD Feathers Dedicated Window Software for editing and programming of all ETOS products ETOS-PD (Protocol Designer) Ensures user convenience with using Window standard user interface Basic parameters setting function for Ethernet and serial communication Driver setting function per each port Function to edit of sending and receiving Frame Function to edit Process program Function to download and upload ETOS’ s parameters and Programs Function to edit communication Items(Send and receive Command) Supports various commands(Item)(Frame Send, Frame Receive, Data Conversion, File save command) Function to monitor ETOS’s memory Real time sending / receiving frame monitoring function (Support Time Stamp) Function to upgrade the ETOS O/S Function to edit, program , download, upload, monitor to ETOS at remote site It is very useful to maintain and monitor ETOS at remote site Parameters Setting Function Setting of Port type such as Serial and Fieldbus Setting of each serial port’ s communication method Setting of Modem control parameters Setting of high grade parameter for serial communication Setting of Serial Communication Drivers Setting of Ethernet Communication Drivers Setting of Ethernet parameters Setting of TCP/IP Setting of Backup Memory Area Setting of Redundant Parameters 23 AC&T System ETOS-PD (Protocol Designer) ETOS-PD Powerful Window Software Package to simply connect between all communication devices Frame Editing Function Possible to communicate all communication devices with User Defined Functions of Serial and Ethernet Frame Possible to set various Frame classified by communication port and channel Possible to convert received dates to ASCII and HEX code Supports various BCC checking function Process Editing Function ETOS Dedicated Program to make ETOS’s execution according to predefined the Frames and Parameter setting Able to define Process program up to 1024 Multi-Process lets ETOS be able to execute according to predefined conditions Individual Process is consisted of various suitable Process Items for user’ s purpose Process end,Condition Branch,Arithmetic, Conversion, Send/Receive, and loop etc) classified by uses Offers Process editing, deleting and copying function Monitoring of Sending and Receiving Frame ETOS-PD (Protocol Designer) Offers various Items (Such as Process start, Real time monitoring function of sending and receiving frames on Ethernet / Serial ports Easy to diagnose and analyze by simultaneous displaying of communication time and data Function to edit and copy monitored frames (save File) Function to convert monitored frames to ASCII and HEX code Function to monitor Ethernet Frame Possible to simultaneous monitor up to 4 channels Reading and Writing of ETOS memory Status verification of sent and received data with ETOS’s User Memory monitoring System Log Memory Monitor User Memory writing function http://www.acnt.co.kr 24 TS-WIN TS-WIN Powerful Window Software Package to offer self-diagnosis and communication diagnosis using ETOS-TS Series TS-Win is Window Software Package to edit and set parameters of ETOS-TS Series, and to monitor of communicating Status and Frame. At first Users edit basic parameters and communication type to communicate with general purpose serial devices (RS232, RS422 and RS485), open communication devices and managing Ethernet devices with using ETOS-TS, and then download the edited contents to ETOS to be working in various protocol operations Serial and Ethernet Parameters Setting Simple setting function of parameter for Ethernet and serial Simple and easy User Interface Communication type setting for individual Serial TS-WIN port Setting of Modem Parameters Setting of high grade item on Serial ports Setting of TCP/IP Operating Status Monitoring Network management Multi-ETOS-TS Setting Multi-ETOS-TS Monitoring Offers various diagnosis information Offers status monitoring information Offers status history information Monitoring of Sending and Receiving Frame on Ethernet and Serial network Possible multi-monitoring up to 4 channels Possible simultaneously to monitor Ethernet and Serial Real time monitoring function of sending and receiving frames on Serial ports Easy to diagnose and analyze by simultaneously displaying of communication time and data 25 AC&T System ETOS Ordering Information Product ETOS-1000 ETOS-300 ETOS-200 ETOS-150 ETOS-150D ETOS-100A ETOS-100D (Dual Net) Specification Redundant CPU Redundant CPU, Ethernet 1 port ETOS-1000-SCP Single CPU Single CPU, Ethernet 1 port ETOS-1000-S40 Serial RS232C 4 Ports ETOS-1000-S80 Serial RS232C 8 Ports ETOS-1000-S04 Serial RS422/RS485 4 Ports ETOS-1000-S08 Serial RS422/RS485 8 Ports ETOS-1000-S44 Serial(Mixed Type) RS232 4 Ports /RS422 4 Ports ETOS-1000-PSR Redundant Power Redundant Power(AC110/220V, 50/60HZ) ETOS-1000-PSS Single Power Power(AC110/220V, 50/60HZ) ETOS-1000-BAS Housing Base Module + Housing ETOS-1000-NUL Dummy Cover Empty Slot Cover ETOS-300-F0 Main Ethernet 1 Port+RS232 16Ports+Single Power ETOS-300-0F Main Ethernet 1 Port+RS422 16Ports+Single Power ETOS-300-F0R Main Ethernet 1 Port+RS232 16Ports+Redundant Power ETOS-300-0FR Main Ethernet 1 Port+R422 16Ports+Redundant Power ETOS-300D-F0 Main Ethernet 2 Ports+RS232 16Ports+Single Power ETOS-300D-0F Main Ethernet 2 Ports+RS422 16Ports+Single Power ETOS-300D-F0R Main Ethernet 2 Ports+RS232 16Ports+Redundant Power ETOS-300D-0FR Main Ethernet 2 Ports+R422 16Ports+Redundant Power ETOS-300D-SGATE Main Ethernet 2 Ports+RS232 16Ports+SECS-I<->HSMS Bridge ETOS-300D-SECS Main Ethernet 2 Ports+RS232 16Ports+HSMS ETOS-200-RCP Main + Redundant CPU Redundant CPU: Ethernet 2 Ports+Base+Housing+Power ETOS-200-SCP Main + Single CPU Single CPU : Ethernet1 Ports+Base+Housing+Power ETOS-200-S40 Serial RS232 4 Ports ETOS-200-S80 Serial RS232 8 Ports ETOS-200-S04 Serial RS422 / RS485 4 Ports ETOS-200-S08 Serial RS422 / RS485 8 Ports ETOS-200-S44 Serial(Mixed Type) RS232 4 Ports and RS422 4 Ports ETOS-200-HSMS Main + Serial Ethernet 1 Port+RS232 8 Ports with HSMS (Programming) ETOS-200-Sgate Main + Serial Ethernet 1 Port+RS232 8 Ports with SECS-I <->HSMS Bridge(Parameter method) ETOS-150-HSMS SECS/HSMS통신 Ethernet 1 Port+RS232 2 Ports + HSMS ETOS-150-Sgate SECS/HSMS통신 Ethernet 1 Port+RS232 2Ports + SECS <-> HSMS Bridge ETOS-150D-HSMS SECS/HSMS통신 Ethernet 2 Port(Redundant)+RS232 2 Ports + HSMS ETOS-100A-S20 Main RS232 2 Ports ETOS-100A-S02 Main RS422 2 Ports ETOS-100A-S11 Main RS232 1 Port , RS422 1 Port ETOS-100A-E20 Main Ethernet 1 Port,RS232 2 Ports ETOS-100A-E02 Main Ethernet 1 Port,RS422 2 Ports ETOS-100A-E11 Main Ethernet 1 Port,RS232 1 Ports , RS422 1 Port ETOS-100D-E20 Main Ethernet 2 Ports, Redundant RS232 2 Ports ETOS-100D-E02 Main Ethernet 2 Ports, Redundant RS422 2 Ports ETOS-100D-E11 Main Ethernet 2 Ports,RS232 1 Ports , RS422 1 Port ETOS Ordering Information ETOS-300D Classification Model ETOS-1000-RCP 26 ETOS Ordering Information Product ETOS-100 Option Module ETOS-50A ETOS-Profibus ETOS-CC-Link Ordering Information ETOS-DNA-PLUS ETOS-TS [*1] [*2] 27 Model Classification Specification ETOS-OPT-232 Serial Option ETOS100/150 Series Option RS232 2 Ports ETOS-OPT-422 Serial Option ETOS100/150 Series Option RS422 2 Ports ETOS-OPT-Fnet Fieldbus Option ETOS100/150 Series Option LSIS Fnet ETOS-OPT-DPM Fieldbus Option ETOS100/150 Series Option Profibus-DP master ETOS-50A-S20 Main RS232 2 Ports ETOS-50A-S02 Main RS422 2 Ports Main RS422 1 Port(COM1), RS232 1 Port(COM2) ETOS-50A-E10 Main Ethernet 1 Port, RS232 1 Port ETOS-50A-E01 Main Ethernet 1 Port, RS422 1 Port ETOS-50A-S11 [*1] ETOS-50A-Sgate Main Ethernet 1 Port, RS232 1 Port (Convert SECS-I to HSMS) ETOS-DPS-S02 Main Profibus-DP Slave ,RS422/485 2 Ports ETOS-DPS-S20 Main Profibus-DP Slave ,RS432 2 Ports ETOS-CCS-E00 Main CC-Link Slave , Ethernet 1ch ETOS-CCS-S02 Main CC-Link Slave ,RS232/485 2 Ports ETOS-CCS-S20 Main CC-Link Slave ,RS232 2 Ports ETOS-DNA-PLUS-S20 Main(Classify by port) Serial (RS232) 2 Ports ETOS-DNA-PLUS-S02 Main Serial (RS422) 2 Ports ETOS-DNA-PLUS-S40 Main Serial (RS232) 4 Ports ETOS-DNA-PLUS-S04 Main Serial (RS422) 4 Ports ETOS-DNA-PLUS-S22 Main Mixed Serial RS232 2 Ports, RS422 2 Ports ETOS-DNA-PLUS-E20 Main Ethernet 1 Port, RS232 2 Ports ETOS-DNA-PLUS-E02 Main Ethernet 1 Port, RS422 2 Ports ETOS-DNA-PLUS-E40 Main Ethernet 1 Port, RS233 4 Ports ETOS-DNA-PLUS-E04 Main Ethernet 1 Port, RS422 4 Ports ETOS-DNA-PLUS-E22 Main Ethernet 1 Port, RS232 Ports , RS422 2 Ports DNA-PLUS-OPT-RY16 Input and Output Option Relay Output 16 Points DNA-PLUS-OPT-TR16 Input and Output Option Tr Output 16 Points DNA-PLUS-OPT-DC16 Input and Output Option DC24V Input 16 Points DNA-PLUS-OPT-DT15 Input and Output Option (Classify by I/O) TR Output 7 Points / DC 24V Input 8 Points (for combined input and output) DNA-PLUS-OPT-DR16 Input and Output Option Relay Output 8 Points / DC24V Input 8 Points (for combined input and output) DNA-PLUS-OPT-AD4 Input and Output Option Analog Input 4 ch[*2] ETOS-TS-F0 Main Ethernet 2 Port,RS232 16 Ports, Single Power ETOS-TS-0F Main Ethernet 2 Port,RS422 16 Ports, Single Power DNA-TS-80 Main Ethernet 2 Port,RS232 8 Ports, Single Power DNA-TS-08 Main Ethernet 2 Port,RS422 8 Ports, Single Power DNA-TS-FOR Main Ethernet 2 Port,RS232 16 Ports, Redundant Power DNA-TS-OFR Main Ethernet 2 Port,RS422 16 Ports, Redundant Power DNA-TS-80R Main Ethernet 2 Port,RS232 8 Ports, Redundant Power DNA-TS-08R Main Ethernet 2 Port,RS422 8 Ports, Redundant Power On serial 2-ports, Com1 is fixed to RS 422/485, and Com2 is fixed to RS 232 Refers Analog specification of ETOS-DNA ETOS ETOS Wiring Diagram Communication Port Pin Assignation C o m m un i c a t i o n C l a s s i f i c a t i o n Pin Number [*1] 1 2 3 4 5 6 7 8 9 RS-233 CD RXD TXD DTR S.G DSR RTS CTS - RXD+ TXD+ - S.G - TXD- RXD- - - S.G - - - RD- - - - RS-422 - RS-485 [*1] - Ethernet TD+ TRX+ - TRX- TD- RD+ - - TRX+ - - - - TRX- - DA DB DG Shield - - - - - - - - - TRX+ TRX- - - Profibus CC-Link Fnet - To use as RS485 is should be shorted each 2nd pin and 3rd pin, 7th pin and 8th pin Communication Port connector Spec ETOS-50 ETOS-100A/100D ETOS-200 ETOS-150/150D ETOS-300 ETOS-1000 ETOS-300D ETOS-TS ETOS - DNA - PLUS ETOSCC-Link ETOS-Profibus RS-232 RS-422 RJ-45(8PIN) DSUB-9(FeMale) RS-485 Ethernet RJ-45(8PIN) Profibus - CC-Link Fnet DSUB-9 - - - - - DSUB-9 - - - - - - Plug(4Pin) - - DSUB-9 - - - - - - Dimension [Unit : mm] ETOS-1000 19” RACK 6U/ Cabinet Wall Mount Front View Top View Side View Wiring Diagram/Dimension C o m m un i c a t i o n C l a s s i f i c a t i o n ETOS Series Classification ETOS-300/300D Front View Top View ETOS-300 ETOS 28 ETOS Dimension [Unit : mm] ETOS-200 19” RACK 2U/ Cabinet Wall Mount Front View Top View Side View ETOS-150/ 100 Top View (Wall Mount) Side View Front View Dimension ETOS-50 Top View Side View (Din Rail) Front View ETOS-Profibus Front View (Wall Mount) 29 Side View (Din Rail) Rear View ETOS ETOS Dimension [Unit : mm] ETOS-CC-Link Front View (Wall Mount) Side View (Din Rail) Rear View ETOS-DNA-PLUS Front View Side View (Din Rail) Top View (Wall Mount) Dimension ETOS-TS Front View Top View ETOS-300 Communication Connector Shape Diagrams RJ-45 Connector D-SUB 9-PIN(Female) D-SUB 9-PIN(Male) PLUG(4-PIN) CC-Link ETOS 30 AC&T System Co.,Ltd. http://www.acnt.co.kr Phone : +82-31-386-7795 (Ext. 401) Fax : +82-31-386-7796 Adress : A607 ACROTOWER,1591, Gwanyang-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-060 Korea