ETOS-Profibus

Transcription

ETOS-Profibus
AC&T System Co.,Ltd.
History of AC&T System
1998
- Established of AC&T System
- Choose industrial Ethernet and Serial Server (ETOS) as item to be developed
1999
-
2000
- Registered with Venture’
s Business
- Launched ETOS-50 to domestic markets
- Attracted an Investment from SAMSUNG Capital
2001
- Launched ETOS-150 to domestic markets
- Launched ETOS-1000 to domestic markets
- Launched ETOS-200 to domestic markets
2002
- Got a patent for ETOS
(Title : Easy Programmable Gateway System and its controlling methods)
2003
- ETOS has received the Certification as Infor-communication devices
- Contraction with LGIS about O.E.M of ETOS
- Contraction with Hynix (Semiconductor manufacture) to supply ETOS
2004
- Win the Prize of Sincere Economist issued by provincial governor
- Launched ETOS-150D to domestic markets
- Win the Prize of Commendation issued by Minister of Science and
Technology Administration
2005
-
2006
- i-Fos F4/50/100/200 has received the international authentication CE
- Selected as Excellent Technology Business Company
2007
- Got a patent for Switch system including VLAN (Virtual Lan)
Module Board and how to initialize this system
- ETOS-TS/300 has received the international authentication CE
Transformed to a Corporation from personal company of AC&T System
Executed industry-university cooperated project to develop the SECS and HSMS
Got a patent for ETOS
Joined in Profibus Association of Korea
Established a Research Laboratory titled“Communication System Laboratory”
Launched ETOS-100 to domestic markets
Launched ETOS-DNA to domestic markets
Launched ETOS-CC-Link to domestic markets
Launched ETOS-Profibus to domestic markets
Selected as Excellent Technology Business Company
ETOS
Industrial Communication Server
INDEX
ETOS-SERIES Introduction/ 3 Specification/ 5
ETOS-1000/ 8
ETOS-150/ 11
ETOS-100D/ 14
ETOS-CC-Link/ 17
ETOS-PD(Protocal Design)/ 23
ETOS-300/300D/ 9
ETOS-150D/ 12
ETOS-50A/ 15
ETOS-DNA-PLUS/ 18
TS-WIN/ 25
Ordering Information/ 26
Dimension/ 28
ETOS-200/ 10
ETOS-100A/ 13
ETOS-Profibus/ 16
ETOS-TS/ 22
Industrial Communication Server
ETOS
2
ETOS
ETOS-SERIES Introduction
ETOS is industrial data communication server greatly improved for user convenience and system installing convenience with using User Defined Concepts for
communicating between various devices based on serial, Ethernet, and Fieldbus
in industrial area. It makes possible to communicate between all devices of
industrial area with having built-in communication drives, easy user defined and
powerful monitoring/debugging function. So it gives users a lot of benefits to
reduce labor and time costs required to open communication.
ET OS -S ERIES Fe at he r s
High performance Industrial Communication Server used a 32Bit RISC CPU
ETOS-SERIES Introduction
Supports high reliability and performance function with using Real Time OS
Enable to install optimized system at various applications with combined serial ports
(offers up to 64 serial ports)
Each serial port (Max up to 64 ports) can individually and simultaneously communicate with each
counter device
Supports wire(dedicated Modem) and wireless(CDMA/RF Modem)
Supports calling and receiving function of CDMA and sending SMS function
Supports various serial communicating drivers(GLOFA Cnet/Modbus/Melsec)
User Defined Communication with using frame defining function(commonly serial and Ethernet)
Supports Ethernet communication of 100BASE-T and 10BASE-T (IEEE802.3)
Supports Ethernet network redundancy (ETOS-1000/ETOS-300D/ETOS-200/ETOS-150D/ETOS-100D)
Supports redundancy of CPU and Power (ETOS-1000/ETOS-200)
Offers various Ethernet communication drivers (GLOFA Enet/ModbusTCP/Melsec)
Supports function of high speed link service(Possible to link with LSIS Ethernet)
Supports DHCP (when using xDSL)
Supports Data backup with using Battery circuits
Supports data saving, calculating, processing function with using abundant memory
Offers various command(such as data translation, calculation, saving, and copying etc)
Supports abundant communication trouble checking function(SUM/XOR/OR/CRC/LRC ETC)
Functions monitoring and controlling of Analog / Digital input/output(ETOS-DNA-PLUS)
Functions monitoring memory, and editing frame and process with using ETOS-PD
Real time frame monitoring function => communicating status diagnosis and observing function
Abundant Self-diagnosing Functions(LED Display, Log Data)
3
ETOS
ETOS
ETOS-SERIES Introduction
Don’t miss your connection : AC&T System offers you flexible, highly available
and future-safe network technology solutions in the usual high quality from simple switches through field bus systems to high performance Ethernet componets.
Using ETOS,
it is possible to monitor and communicate between various controllers.
Integration of different type of communications
Ethernet / Serial(RS232 / RS422 / RS485) /SECS-I / HSMS/ Profibus /CC-Link/ Fnet
Network integration of unit equipments
Integration of communicating device of equipment and Ethernet
Remote control and managing with using Dedicated line and Internet line
ETOS-SERIES Introduction
KT-Dedicated line, CDMA wireless, CDMA SMS, DHCP Changeable IP
Installation of Integrated supervising and controlling system
It is possible to monitor up to max 64’
s remote equipments, and possible to achieve
the server role of gathered data’s saving and converting.
SECS communication between semiconductor equipments
Combined and serial communication between SECS-I and HSMS
Integrated communication between serial and Ethernet
Communication between all serial devices, and communication between serial device and
Ethernet device
Communication with Open Fieldbus devices
ETOS is possible to link with Profibus-DP’s devices and CC-Link’
s devices
Communication with Dedicated network
Possible to link with LSIS’s Fnet and I-NET
ETOS
4
ETOS
ETOS Specification
Environment Specification
Related standard
Specification
Items
Operating
Temperature
-10℃
~ +60℃
Storage
Temperature
-25℃
~ +70℃
Operating
Humidity
5~95%RH, Non-condensing
Storage Humidity
5~95%RH, Non-condensing
For discontinuous vibration
Vibration
Frequency
Acceleration
Amplitude
10≤f�57Hz
-
0.075mm
57≤f≤150Hz
9.8㎨ (1G)
-
The Number of
times
IEC 1131-2
For continuous vibration
Acceleration
Amplitude
10≤f�57Hz
-
0.035mm
57≤f≤150Hz
4.8㎨ (0.5G)
-
Frequency
Each 10 times in
X,Y,X directions
ETOS Specification
* Max. Impact acceleration : 147㎨ (15G)
* Authorized time : 11ms
* Pulse waveform : Sine Haft-wave Pulse
(Each 3 times in X,Y,X directions)
Impact
Square wave
Impulse Noise
± 1500V
Static electric
discharging
Voltage : 4Kv(contact discharging)
Radiation field
noise
Noise
Test Spec. referred
within AC&T
IEC 1131-2,
IEC 801-2
IEC 1131-2,
IEC 801-3
27~500 MHz, 10V/㎖
Classi- Power
Fast
transient/burst fication Module
noise
Voltage
Digital I/O
Digital I/O(24V Above)
(24V Above)
2kV
1kV
Ambient conditions
No corrosive gas and dust
Pollution level
Below 2
Cooling type
Natural air cooling(Fan-less)
Analog I/O
Network Interface
IEC 1131-2,
IEC 801-4
0.25kV
Power Specification
Model
5
ETOS-CC-LInk ETOS-DNA
ETOS-100
ETOS-300
ETOS-50
ETOS-200
ETOS-Profibus -PLUS
ETOS-150
ETOS-300D
Input
Source
DC24V
Capacity
5V/500mA
AC 110V/220V(50/60Hz), Free Voltage
5V/4A
5V/1A
5V/2.5A
5V/7A
ETOS-TS
AC 90~260V,
50/60Hz
5V/3A
ETOS-1000
AC110V/220V,
select
5V/15A
12V/3A
ETOS
ETOS
ETOS Specification
Performance Specification
Model ETOS-DNA-PLUS
Classification
ETOS-Profibus
ETOS-CC-Link
ETOS-50A
ETOS-100A
User Memory
256K,1M,2M,4MBytes
64KBytes
64KBytes
64KBytes
256KBytes
Backup Memory
Supports
-
-
-
Supports
Program Memory
1.0MBytes
1.0MBytes
1.0MBytes
1.0MBytes
1.0MBytes
Log Memory
256KBytes
256KBytes
256KBytes
256KBytes
256KBytes
Ethernet Ports(Max.)
1
1
1
1
1
Serial Ports(Max.)
4
2
2
2
4
I/O
64channel
-
-
-
-
WatchDog
Supports
-
-
-
Supports
RTC
Supports
-
-
-
Supports
Power
-
-
-
-
-
CPU
-
-
-
-
-
Ethernet
-
-
-
-
-
ETOS-150
ETOS-100D
ETOS-150D
ETOS-200
ETOS-1000
256KBytes
512KBytes
2.0MBytes
256KBytes
512KBytes
Redundancy
Model
Cla ssification
User Memory
Backup Memory
Supports
Supports
Supports
Supports
Supports
Program Memory
1.0MBytes
2.0MBytes
1.0MBytes
2.0MBytes
2.0MBytes
Log Memory
256KBytes
512KBytes
256KBytes
512KBytes
512KBytes
Ethernet Ports(Max.)
1
2
2
2
2
Serial Ports(Max.)
4
4
4
16
64
I/O
-
-
-
-
-
WatchDog
Supports
Supports
Supports
-
-
RTC
Supports
Supports
Supports
Supports
Supports
Power
-
-
-
-
Supports
CPU
-
-
-
Supports
Supports
Ethernet
-
Supports
Supports
Supports
Supports
Redundanc y
ETOS Specification
Performance Specification
Performance Specification
Model
ETOS-TS
ETOS-300
ETOS-300D
User Memory
8.0MBytes
8.0MBytes
-
Backup Memory
Supports
Supports
-
Classificati on
Program Memory
1.0MBytes
1.0MBytes
-
Log Memory
1024KBytes
1024KBytes
1024KBytes
Ethernet Ports(Max.)
1
2
2
Serial Ports(Max.)
8/16
8/16
8/16
I/O
-
-
-
WatchDog
Supports
Supports
Supports
RTC
Redundancy
Supports
Supports
Supports
Power
Supports
Supports
Supports
CPU
-
-
-
Ethernet
-
Supports
Supports
* The Specification of ETOS can be changed for performance improving without a previous notice
ETOS
6
ETOS
ETOS Specification
Ethernet communication Spec
Specifications
Classifications
Speed
10Mbps / 100Mbps
Transmitting Method
BaseBand
Max. Segment Distance
100M(Node - Hub간 길이)
Max. Protocol Data Size
1500 Byte
Protocol
TCP/IP, UDP/IP, DHCP
Media Access
CSMA/CD, IEEE 802.3
D e d i c a t e d C o m m u n i c a t i o n D r i v e r s [*1][*2]
LSIS’
s Enet Dedicated Protocol,Modbus TCP,Melsec-A/Q Series,POSFA
High Speed Link
LSIS’s Enet Dedicated Protocol
Should be set to Ethernet V2.0 when communicates with Modbus TCP and Melsec Driver
[*1]
[*2]
LSIS Enet and ModbusTCP support both Master and Slave service, but Melsec and POSFA
support only Master service
ETOS Specification
Serial communication Spec
Specifications
Classifications
Data Bit
7 or 8 Bit
Stop Bit
1 or 2 Bit
Start Bit
1 Bit
Parity Bit
Even/Odd/None/Space/Mark
Synchronous method
Asynchronous
Speed(BPS)
300/600/1200/1800/2400/3600/4800/7200
9600/19200/38400/57600/64000/115200
DCE Modem to be used
Dedicated Modem, CDMA Modem ,Dial-UP Modem, Null Modem
Distance
RS-232C : 15M / RS-422 : 500M
Dedicated Communication Drivers
[*1]
[*1]
LSIS Cnet, Modbus-ASII/RTU, Melsec-A/Q
LSIS Cnet and Modbus-ASII/RTU support Master and Slave service, but Melsec supports only
Master service
Fieldbus Communication Spec
Protocol
Profibus-DP
CC-Link
7
Protocol Models
ETOS-OPT-DPM
ETOS-DPS
ETOS-CC-Link
Specifications
Profibus-DP Master
Profibus-DP Slave
EN 50170/DIN 19245
Compatible with CC-Link v2.0
Fnet
ETOS-OPT-Fnet
Compatible with LSIS Fnet
inet
GMPC-Master
Compatible with LSIS Fnet
ETOS
ETOS-1000
ETOS-1000
Be s t S o lut i o n f o r C e nt r ali ze d
S C A DA and C ELL co nt r o l s y s t e m
ETOS-1000 Feathers
Ensures reliability with supporting redundancy of CPU and Power
Supports network redundancy with dual Ethernet
Connects up to 64 serial(RS232/RS422/RS485) ports
Possible to extend RS232/RS422 channel with 4 or 8 units
Gives more convenience to Users to install large system integrating
with abundant user memory(512kbytes)(TM Masterr/SCADA System)
ETOE
ST-O
SS
ER1IE
0S
00개요
Modules
Classification
Specification
Model
Redundant CPU
ETOS-1000-RCP
Redundant CPU, Ethernet 1 port
Single CPU
ETOS-1000-SCP
Single CPU, Ethernet 1 port
Serial
ETOS-1000-S40
RS232C 4 Ports
Serial
ETOS-1000-S80
RS232C 8 Ports
Serial
ETOS-1000-S04
RS422/RS485 4 Ports
Serial
ETOS-1000-S08
RS422/RS485 8 Ports
Serial(Mixed Type)
ETOS-1000-S44
RS232 4 Ports /RS422 4 Ports
Redundant Power
ETOS-1000-PSR
Redundant Power(AC110V/220V, 50/60Hz)
Single Power
ETOS-1000-PSS
Power(AC110V/220V, 50/60Hz)
Housing
ETOS-1000-BAS
Base Module + Case
Dummy Cover
ETOS-1000-NUL
Empty Slot Cover
ETOS-1000 Application Systems
http://www.acnt.co.kr
8
ETOS-300/300D
S uppo r t s S EC S -I/ H S MS t hat i s s e m i co nduct o r e qui pm e nt s
s t andar d pr o t o co l as Dat a C o m m uni cat i o n S e r ve r f o r
m i ddle s i ze d s y s t e m i nt e gr at i o n
ETOS-DNA
ETOS-300/300D
ETOS-300/300D Feathers
Network integration of standard network, serial and Ethernet
Editing functions of serial and Ethernet frame
Supports abundant user memory (8Mbytes)
Offers Ethernet communication redundancy (Supports only ETOS-300D)
redundant Power(optional)
Supports SECS-I/HSMS that is semiconductor equipments standard protocol
EE
TT
OO
SS
-S3
E0R0IE
/3
S00
개D요
Modules
Classification
Model
Main
ETOS-300-FO
Ethernet 1 Port+RS232 16Ports+Single Power
Main
ETOS-300-OF
Ethernet 1 Port+RS422 16Ports+Single Power
Main
ETOS-300-FOR
Ethernet 1 Port+RS232 16Ports+Redundant Power
Main
ETOS-300-OFR
Ethernet 1 Port+R422 16Ports+Redundant Power
Main
ETOS-300D-FO
Ethernet 2 Ports+RS232 16Ports+Single Power
Main
ETOS-300D-OF
Ethernet 2 Ports+RS422 16Ports+Single Power
Main
ETOS-300D-FOF
Ethernet 2 Ports+RS232 16Ports+Redundant Power
Main
ETOS-300D-OFR
Ethernet 2 Ports+R422 16Ports+Redundant Power
Main
ETOS-316D-SGATE
Ethernet 2 Ports+RS232 16Ports, SECS-I<->HSMS Bridge
Main
ETOS-316D-SECS
Ethernet 2 Ports+RS232 16Ports, HSMS
ETOS-300/300D Application System
9
AC&T System
Specification
ETOS-200
S uppo r t s S EC S -I/ H S MS t hat i s s e m i co nduct o r
e qui pm e nt s s t andar d pr o t o co l and T M Mas t e r
f o r m e ddle s i ze d s y s t e m i nt e gr at i o n
ETOS-200
ETOS-200 Feathers
Supports SECS-I/HSMS that is semiconductor equipments standard protocol
Supports Ethernet and CPU redundancy
Supports up to 16 serial ports (RS-232/422/485)
Supports abundant user memory(512k byte)
Offers merits to install of middle sized network integration
Modules
Classification
Specification
Model
ETOS-200-RCP
Redundant CPU(Ethernet 2 Ports)+Base+Housing+Power
Single CPU
ETOS-200-SCP
Single CPU(Ethernet 1 Ports)+Base+Housing+Power
Serial
ETOS-200-S40
RS232 4 Ports
Serial
ETOS-200-S80
RS232 8 Ports
Serial
ETOS-200-S04
RS422 / RS485 4 Ports
Serial
ETOS-200-S08
RS422 / RS485 8 Ports
Serial(Mixed Type)
ETOS-200-S44
RS232 4 Ports and RS422 4 Ports
SECS/HSMS
ETOS-200-HSMS
Ethernet 1 Port+RS232 8 Ports with HSMS
SECS/HSMS
ETOS-200-Sgate
Ethernet 2 Ports+RS232 8 Ports with SECS-I<->HSMS Bridge
Redundant Power
ETOS-200-PSR
ETOS-200-HSMS
Base +
Redundant
100/220V,
이더넷
1포트 + Power(AC
RS232 8포트/
HSMS 50/60Hz)
통신
ETOS-200-PSS
Base + Single Power(AC 100/220V, 50/60Hz)
Single Power
ETOS-200
Redundant CPU
ETOS-200 Application System
Control and Monitoring Center
CDMA
Base Station
CDMA Modem
Remote-Site-A
CDMA Modem
Dedicated Line
Modem
Dedicated Line
Modem
KT Dedicated Line
Dedicated Line
Modem
Dedicated Line
Modem
Remote-Site-B
Dedicated Line
Modem
Remote-Site-C
Dedicated Line
Modem
Electric Power Meter
http://www.acnt.co.kr
10
ETOS-150
ETOS-150
Indus t r i al C o m m uni cat i o n S e r ve r f o r S EC S t hat i s s e m i co nduct o r
e qui pm e nt s t andar d co m m uni cat i o n pr o t o co l
ETOS-150 Feathers
Supports SECS-I/HSMS that is semiconductor equipments standard protocol
Supports SECI-I , SECS-II and HSMS regardless of the controller
(PC,PLC, or Dedicated controller) of equipment
Integration of semiconductors and an upper managing system
regardless of supporting the SECS protocol or not
Modules
Classification
Model
Main
ETOS-150-HSMS
Ethernet 1 Port+RS232 2 Ports / HSMS
Main
ETOS-150-Sgate
Ethernet 1 Port+RS232 2 Ports / SECS <-> HSMS Bridge
Specification
ETOS-150
* Possible to add serial option 2 ports of ETOS-100 if want to extend serial ports
Procedures of using of EOTS-150
1. Convert general RS232 to SECS-I or HSMS
- Convert any data of equipment and controller (PLC, Dedicated controller) not to support SECS
into SECS standard protocol
- Possible to make the semiconductor standard protocol quickly
2. Convert SECS-I to HSMS(Ethernet)
- Possible to install the HSMS quickly on equipment to support only SECS-I
- Supports HSMS protocol by simple parameter setting
- Supports communication speed range of 9600bps to 115200bps on SECS-I
- Able to use host and equipment on HSMS
ETOS-150 Application System
11
AC&T System
ETOS-150D
Intelligent Industrial Communication Server to support redundancy
of Ethernet, and to support Semiconductor equipment ’s
standard communication Protocol (SECS/HSMS)
ETOS-150D
ETOS-150D Feathers
Supports network(Ethernet) redundancy (Dual MAC)
Able to separate factory network from office network
because redundant Ethernet 2 ports are simultaneously
working (Protect to occur communication trouble of
FA network by traffic congestion of office PC
Supports SECS-I/HSMS that is semiconductor equipments standard protocol
Supports SECI-I, SECS-II and HSMS regardless of the controller
(PC,PLC, or Dedicated controller) of equipment
Integration of semiconductors and an upper managing system regardless of supporting
Modules
Classification
Model
Specification
Main
ETOS-150D-HSMS
Ethernet 2 Ports(Redundant)+RS232 2 Ports/HSMS
* Possible to add serial option 2 ports of ETOS-100 if want to extend serial ports
ETOS-150D
the SECS protocol or not
ETOS-150D Application System
http://www.acnt.co.kr
12
ETOS-100A
Intelligent Industrial Communication Server to be used to
integrate the middle and small sized network,
and to integrate local multi-devices
ETOS-100A
ETOS-100A Feathers
Able to simultaneously connect up to 4 serial ports on Ethernet 1 port
Operate independently 4 serial ports
(able to connect simultaneously up to 4 serial ports)
Support simultaneously Client and Server function of Ethernet
Convert protocols between Ethernet and Serial
Supports open Fieldbus
- Profibus-DP Master
- LSIS Fnet
ETOS-100A
Modules
Classification
Model
ETOS-100A-S20
RS232 2 Ports
Main
ETOS-100A-S02
RS422 2 Ports
Main
ETOS-100A-S11
RS232 1 Port , RS422 1 Port
Main
ETOS-100A-E20
Ethernet 1 Port,RS232 2 Ports
Main
ETOS-100A-E02
Ethernet 1 Port,RS422 2 Ports
Main
ETOS-100A-E11
Ethernet 1 Port,RS232 1 Ports , RS422 1 Port
Serial Option
ETOS-OPT-232
RS232 2 Ports
Serial Option
ETOS-OPT-422
RS422 2 Ports
Fieldbus Option
ETOS-OPT-Fnet
LSIS Fnet
필드버스 옵션
ETOS-OPT-DPM
Profibus-DP master
ETOS-100A Application System
13
AC&T System
Specification
Main
ETOS-100D
ETOS-100D
Intelligent Industrial Communication Server to integrate local
networks based on Ethernet redundancy
ETOS-100D Feathers
Supports network(Ethernet) redundancy (Dual MAC)
Able to simultaneously connect up to 4 serial ports on Ethernet 1 port
Operate independently 4 serial ports channels
(able to connect simultaneously up to 4 serial ports)
Support simultaneously Client and Server function of Ethernet
Convert protocols between Ethernet and Serial
Supports open Fieldbus
-Profibus-DP Master
-LSIS Fnet
Classification
Model
Specification
Main
ETOS-100D-E20
Ethernet 2 Ports,RS232 2 Ports
Main
ETOS-100D-E02
Ethernet 2 Ports,RS422 2 Ports
Main
ETOS-100D-E11
Ethernet 2 Ports,RS232 1 Ports , RS422 1 Port
Serial Option
ETOS-OPT-232
RS232 2 Ports
Serial Option
ETOS-OPT-422
RS422 2 Ports
Fieldbus Option
ETOS-OPT-Fnet
GLOFA Fnet
Fieldbus Option
ETOS-OPT-DPM
Profibus-DP master
ETOS-100D
Modules
ETOS-100D Application System
http://www.acnt.co.kr
14
ETOS-50A
ETOS-50A
Communications between multi-devices on small and simple network
Communications using Dedicated line and DHCP on remote sites
ETOS-50A Feathers
Able to simultaneously connect 1 serial port on Ethernet 1 port
Converts protocols of multi-devices with 2 serial ports
Suits to protocol converting of united machinery equipment
Supports simultaneously Client and Server function of Ethernet
Converts protocols between Ethernet and Serial
Modules
ETOS-50A
Classification
[*1]
Model
Main
ETOS-50A-S20
RS232 2 Ports
Main
ETOS-50A-S02
RS422 2 Ports
Main
ETOS-50A-S11[*1]
RS422 1 Port(COM1) , RS232 1 Port(COM2)
Main
ETOS-50A-E10
Ethernet 1 Port,RS232 1 Port
Main
ETOS-50A-E01
Ethernet 1 Port,RS422 1 Port
Main
ETOS-50A-Sgate
Ethernet 1 Port,RS232 1 Port(Convert SECS-I to HSMS)
On Serial 2-Ports, Com1 is fixed to RS422, and Com2 is fixed to RS232
ETOS-50A Application System
15
Specification
AC&T System
ETOS-Profibus
ETOS-Profibus
Useful to connecting serial device on profibus-DP network
ETOS-Profibus Feathers
Supports completely Profibus-DP Slave function
Supports simultaneously Client and Server on serial communication
Converts protocols between Profibus and Serial
Connecting devices of different type with serial frame defining function
Serial Communication Drivers(GLOFA, Modbus, Melsec)
Profibus-DP Specifications
Classification
Specification
Protocol
Profibus-DP Slave, EN 50170/ DIN19245
Interface
RS-485(Electrically isolated)
ETOS-Profibus
9600bps~12Mbps/ Auto Baudrate
Speed
1.2Km~100m/Adjust according to Baudrate
Distance
Max. stations
32 Station/ Segment
I/O Data Size
Input 64 Byte/Output 64 Byte
Plug Connector
9 pin D-sub
Cable
Two wire shielded twisted pair cable
Terminal Resistor
220ohm,1/2W (Connect to each A-B line)
Modules
Classification
Model
Specification
Main
ETOS-DPS-S02
Profibus-DP Slave ,RS422 2 Ports
Main
ETOS-DPS-S20
Profibus-DP Slave ,RS232 2 Ports
ETOS-Profibus Application System
http://www.acnt.co.kr
16
ETOS-CC-Link
ETOS-CC-Link
Useful to connect serial device on CC-Link network
ETOS-CC-LINK Feathers
Supports completely CC-Link V2.0 Slave function
Supports simultaneously Client and Server on serial communication
Converts protocols between CC-link and Serial
Converts protocols between CC-link and Ethernet
Function to connect devices of different type with serial frame defining function
Ethernet and serial Communication Drivers(GLOFA, Modbus, Melsec)
CC-Link Specifications
Specification
Classification
ETOS-CC-Link
Protocol
Compatible with CC-Link Slave V2.0
Interface
RS-485(Electric)/Bus Topology
10M/5M/2.5M/625K/156kbps
Speed
Broadcast Polling
Communication Type
x1 /x2 /x4 /x8
Extending Cyclic setting
Max. stations to be able to possess
Max. number of station to be connect to
Cable
4 Stations(Station no is up to 64)
Remote Device stations are up to 42 CC-link
dedicate Cable(Shielded and twisted 3 pairs Cable)
110ohm,1/2W (Connect to each DA-DB line)
Terminal resistor
Modules
Classification
Model
ETOS-CCS-E00
CC-LInk Slave, Ethernet
Main
ETOS-CCS-S02
CC-LInk Slave, RS422 2 ports
Main
ETOS-CCS-S20
CC-LInk Slave, RS232 2 ports
ETOS-CC-Link Application System
17
AC&T System
Specification
Main
ETOS-DNA-PLUS
Best optimized wire and wireless controller to add
function of controlling and monitoring on powerful
communication capability
ETOS-DNA-PLUS
ETOS-DNA-PLUS Feathers
Offers Ethernet 1 port(100BaseT/DHCP/Communication Drivers)
Up to 4 serial communication ports(RS232 / RS422)
Supports wire(Dedicated Modem) and wireless(CDMA/RF Modem)
Function to be sending SMS with CDMA Modem(Event Alarm function)
Various I/O formations(Relay and TR output/ Analog and DC input)
Possible to use as redundant RTU that is consisted of wire and wireless way
Controller for controlling and monitoring of unmanned remote sites
ETOS-DNA PLUS
Modules
Classification
Main
(Classify by port)
Option
(Classify by I/O)
[*1]
Model
Specification
ETOS-DNA-PLUS-S20
Serial (RS232) 2 Ports
ETOS-DNA-PLUS-S02
Serial (RS422) 2 Ports
ETOS-DNA-PLUS-S40
Serial (RS232) 4 Ports
ETOS-DNA-PLUS-S04
Serial (RS422) 4 Ports
ETOS-DNA-PLUS-S22
Mixed Serial RS 232 2 Ports, RS422 2 Ports
ETOS-DNA-PLUS-E20
Ethernet 1 Port + RS232 2 Ports
ETOS-DNA-PLUS-E02
Ethernet 1 Port + RS422 2 Ports
ETOS-DNA-PLUS-E40
Ethernet 1 Port + RS233 4 Ports
ETOS-DNA-PLUS-E04
Ethernet 1 Port + RS422 4 Ports
ETOS-DNA-PLUS-E22
Ethernet 1 Port + RS232 2 Ports / RS422 2 Ports
DNA-PLUS-OPT-RY16
Relay Output 16 Points
DNA-PLUS-OPT-TR16
TR Output 16 Points
DNA-PLUS-OPT-DC16
DC24V Input 16 Points
DNA-PLUS-OPT-DT15
TR Output 7 Points / DC 24V Input 8 Points
(for combined input and output)
DNA-PLUS-OPT-DR16
Relay Output 8 Points / DC24V Input 8 Points
(for combined input and output)
DNA-PLUS-OPT-AD4
Analog Input 4 ch [*1]
Refers Analog Specification of ETOS-DNA
The methods to classify Main Model name : ETOS-DNA-PLUS- X , Y , Z - AA
X : Classify Ethernet and Serial : S = Serial , E = Ethernet
Y : Quantity of RS232 Ports
Z : Quantity of RS422 Ports
AA : User Memory Size
(none, 1M, 2M, 4M)
[Example] ETOS-DNA-E22 : Ethernet 1 Port, RS232 2 Ports, RS422 2 Ports, 256Kbyte user memory
ETOS-DNA-E22-4M : Ethernet 1 Port, RS232 2 Ports, RS422 2 Ports, 4MByte user memory
http://www.acnt.co.kr
18
ETOS-DNA-PLUS
ETOS-DNA-PLUS
Possible to make diverse and abundant
I/O system
Digital Output Specification
Classification
DNA-PLUS-OPT-RY16
DNA-PLUS-OPT-TR16
Input/Output Spec.
Relay Output
TR Ouput
nput/Output Points
16 Points
16 Points
Relay Isolation
Photo coupler Isolation
Isolation method
Polarity Type
Sink type(-COM)
-
Rated Load Voltage
DC24V, AC110V/220V
DC12V, DC24V
Rated Load Current
5A/COM
3A/COM
Response
time
OFF->ON
10 mSecs
2 mSecs
ON->OFF
12 mSecs
2 mSecs
Common method
Status Display
16 Points / 1 COM
8 Points / 1 COM
Display by LED
Display by LED
ETOS-DNA
Digital Input/Output Specification
Classification
DC Input module
Input/Output Points
Input 16 Points
DNA-PLUS-OPT-DT15
Mixed DC Input/TR Output
입력Input
8점/출력
7점
8Points
/Output 7Points
DNA-PLUS-OPT-DR16
Mixed DC Input/Relay Output
입력Input
8점/출력
8점
8 Points
/Output 8 Points
Isolation method
Photo coupler Isolation
Photo coupler Isolation
Polarity Type
Source/Sink (non-Polarity)
-
-
Rated Input Voltage
/Current
Input DC24V/11mA
Refer DC input Module
Refer DC input Module
On Voltage/Current
Off Voltage/Current
Response
time
10 mSecs
ON->OFF
10 mSecs
Status Display
AC&T System
Input DC15V/6mA
Input under DC5V/1mA
OFF->ON
Common method
19
DNA-PLUS-OPT-DC16
Input/Output Spec
8 Points / 1 com
Display by LED
Photo coupler Isolation
-
-
Refer Tr Output Module
Refer Relay Output Module
-
-
Input 8 Points/ 1 COM
Output 7 Points/ 1 COM
Input 8 Points/ 1 COM
Output 8 Points/ 1 COM
Display by LED
Display by LED
ETOS-DNA-PLUS
ETOS-DNA-PLUS
Possible to make abundant
Analog/Digital I/O system
Analog
Input Specification
Classification
Input Spec
Number of Input Channels
Input
Resolution
DNA-PLUS-OPT-AD4
Analog Input Voltage/Current Module
4 Channels
Voltage
DC -10V~+10V, -5V~+5V, 0~10V, 0~5V, 1~5V
Current
DC 1~20mA, 4~20mA
Selecting Voltage/Current
Selecting by Terminal
Digital Output
-16000 ~ +16000
Voltage
0.25 mV
Current
1 uA
Precision Rate
Isolation method
Internal Process
Status Display
ETOS-DNA Analog / Digital
Isolating Input Terminal and Internal circuits by Photo
coupler(Non-Isolation between channels)
10mSec / 1 Channel
Average Process(Average Value Setting function), Sampling
Display by LED
Input / Output Wiring Diagram
http://www.acnt.co.kr
ETOS-DNA
Max. Converting Speed
± 0.1%(Full Scale)
20
ETOS-DNA-PLUS
ETOS-DNA-PLUS
Possible to apply to diverse applications with
combining of control and communication
ETOS-DNA
21
AC&T System
ETOS-TS
ETOS-TS
Connecting between Ethernet and serial network with
simply and easily parameters setting
ETOS-TS Feathers
Easily connects Serial devices to Ethernet(100/10BaseT)
Supports redundant Ethernet(Dual MAC)
Offers diverse TCP/UDP applications
Ensures excellent reliability in harsh industrial environments
Supports Fail Safe Power Supply(Supports redundant Power)
Modules
Classification
Model
Specification
ETOS-TS-FO
Ethernet 2 Ports + RS232 16 Ports + Single Power
Main
ETOS-TS-OF
Ethernet 2 Ports + RS422 16 Ports + Single Power
Main
ETOS-TS-80
Ethernet 2 Ports + RS232 8 Ports + Single Power
Main
ETOS-TS-08
Ethernet 2 Ports + RS422 8 Ports + Single Power
Main
ETOS-TS-FOR
Ethernet 2 Ports + RS232 16 Ports + Redundant Power
Main
ETOS-TS-OFR
Ethernet 2 Ports + RS422 16 Ports + Redundant Power
Main
ETOS-TS-80R
Ethernet 2 Ports + RS232 8 Ports + Redundant Power
Main
ETOS-TS-08R
Ethernet 2 Ports + RS422 8 Ports + Redundant Power
ETOS-TS
Main
ETOS-TS Application System
http://www.acnt.co.kr
22
ETOS-PD (Protocol Designer)
Powerful Window Software Package to simply connect between all
communication devices
ETOS-PD
ETOS-PD is a Window Software Package to program, edit and monitor of the
user program of all ETOS Products. At first Users edit all process programs,
basic parameters and communication type to communicate with general purpose
serial devices (RS232,RS422 and RS485), open communication devices and
managing Ethernet devices with using ETOS-PD, and then download the edited
contents to ETOS to be working in various protocol operations
ETOS-PD Feathers
Dedicated Window Software for editing and programming of all ETOS products
ETOS-PD (Protocol Designer)
Ensures user convenience with using Window standard user interface
Basic parameters setting function for Ethernet and serial communication
Driver setting function per each port
Function to edit of sending and receiving Frame
Function to edit Process program
Function to download and upload ETOS’
s parameters and Programs
Function to edit communication Items(Send and receive Command)
Supports various commands(Item)(Frame Send, Frame Receive, Data Conversion, File save command)
Function to monitor ETOS’s memory
Real time sending / receiving frame monitoring function
(Support Time Stamp)
Function to upgrade the ETOS O/S
Function to edit, program , download, upload, monitor to ETOS at remote site
It is very useful to maintain and monitor ETOS at remote site
Parameters Setting Function
Setting of Port type such as Serial and Fieldbus
Setting of each serial port’
s communication method
Setting of Modem control parameters
Setting of high grade parameter for serial communication
Setting of Serial Communication Drivers
Setting of Ethernet Communication Drivers
Setting of Ethernet parameters
Setting of TCP/IP
Setting of Backup Memory Area
Setting of Redundant Parameters
23
AC&T System
ETOS-PD (Protocol Designer)
ETOS-PD
Powerful Window Software Package to simply connect
between all communication devices
Frame Editing Function
Possible to communicate all communication
devices with User Defined Functions of Serial
and Ethernet Frame
Possible to set various Frame classified by
communication port and channel
Possible to convert received dates to ASCII
and HEX code
Supports various BCC checking function
Process Editing Function
ETOS Dedicated Program to make ETOS’s
execution according to predefined the Frames
and Parameter setting
Able to define Process program up to 1024
Multi-Process lets ETOS be able to execute
according to predefined conditions
Individual Process is consisted of various
suitable Process Items for user’
s purpose
Process end,Condition Branch,Arithmetic,
Conversion, Send/Receive, and loop etc)
classified by uses
Offers Process editing, deleting and copying
function
Monitoring of Sending and Receiving
Frame
ETOS-PD (Protocol Designer)
Offers various Items (Such as Process start,
Real time monitoring function of sending and
receiving frames on Ethernet / Serial ports
Easy to diagnose and analyze by simultaneous
displaying of communication time and data
Function to edit and copy monitored frames
(save File)
Function to convert monitored frames to ASCII
and HEX code
Function to monitor Ethernet Frame
Possible to simultaneous monitor up to 4
channels
Reading and Writing of ETOS memory
Status verification of sent and received data
with
ETOS’s User Memory monitoring
System Log Memory Monitor
User Memory writing function
http://www.acnt.co.kr
24
TS-WIN
TS-WIN
Powerful Window Software Package to offer self-diagnosis and
communication diagnosis using ETOS-TS Series
TS-Win is Window Software Package to edit and set parameters of ETOS-TS
Series, and to monitor of communicating Status and Frame. At first Users edit
basic parameters and communication type to communicate with general purpose
serial devices (RS232, RS422 and RS485), open communication devices and
managing Ethernet devices with using ETOS-TS, and then download the edited
contents to ETOS to be working in various protocol operations
Serial and Ethernet Parameters Setting
Simple setting function of parameter for Ethernet and
serial
Simple and easy User Interface
Communication type setting for individual Serial
TS-WIN
port
Setting of Modem Parameters
Setting of high grade item on Serial ports
Setting of TCP/IP
Operating Status Monitoring
Network management
Multi-ETOS-TS Setting
Multi-ETOS-TS Monitoring
Offers various diagnosis information
Offers status monitoring information
Offers status history information
Monitoring of Sending and Receiving Frame
on Ethernet and Serial network
Possible multi-monitoring
up to 4 channels
Possible simultaneously to monitor Ethernet and Serial
Real time monitoring function of sending and
receiving frames on Serial ports
Easy to diagnose and analyze by simultaneously
displaying of communication time and data
25
AC&T System
ETOS
Ordering Information
Product
ETOS-1000
ETOS-300
ETOS-200
ETOS-150
ETOS-150D
ETOS-100A
ETOS-100D
(Dual Net)
Specification
Redundant CPU
Redundant CPU, Ethernet 1 port
ETOS-1000-SCP
Single CPU
Single CPU, Ethernet 1 port
ETOS-1000-S40
Serial
RS232C 4 Ports
ETOS-1000-S80
Serial
RS232C 8 Ports
ETOS-1000-S04
Serial
RS422/RS485 4 Ports
ETOS-1000-S08
Serial
RS422/RS485 8 Ports
ETOS-1000-S44
Serial(Mixed Type)
RS232 4 Ports /RS422 4 Ports
ETOS-1000-PSR
Redundant Power
Redundant Power(AC110/220V, 50/60HZ)
ETOS-1000-PSS
Single Power
Power(AC110/220V, 50/60HZ)
ETOS-1000-BAS
Housing
Base Module + Housing
ETOS-1000-NUL
Dummy Cover
Empty Slot Cover
ETOS-300-F0
Main
Ethernet 1 Port+RS232 16Ports+Single Power
ETOS-300-0F
Main
Ethernet 1 Port+RS422 16Ports+Single Power
ETOS-300-F0R
Main
Ethernet 1 Port+RS232 16Ports+Redundant Power
ETOS-300-0FR
Main
Ethernet 1 Port+R422 16Ports+Redundant Power
ETOS-300D-F0
Main
Ethernet 2 Ports+RS232 16Ports+Single Power
ETOS-300D-0F
Main
Ethernet 2 Ports+RS422 16Ports+Single Power
ETOS-300D-F0R
Main
Ethernet 2 Ports+RS232 16Ports+Redundant Power
ETOS-300D-0FR
Main
Ethernet 2 Ports+R422 16Ports+Redundant Power
ETOS-300D-SGATE
Main
Ethernet 2 Ports+RS232 16Ports+SECS-I<->HSMS Bridge
ETOS-300D-SECS
Main
Ethernet 2 Ports+RS232 16Ports+HSMS
ETOS-200-RCP
Main + Redundant CPU Redundant CPU: Ethernet 2 Ports+Base+Housing+Power
ETOS-200-SCP
Main + Single CPU
Single CPU : Ethernet1 Ports+Base+Housing+Power
ETOS-200-S40
Serial
RS232 4 Ports
ETOS-200-S80
Serial
RS232 8 Ports
ETOS-200-S04
Serial
RS422 / RS485 4 Ports
ETOS-200-S08
Serial
RS422 / RS485 8 Ports
ETOS-200-S44
Serial(Mixed Type)
RS232 4 Ports and RS422 4 Ports
ETOS-200-HSMS
Main + Serial
Ethernet 1 Port+RS232 8 Ports with HSMS (Programming)
ETOS-200-Sgate
Main + Serial
Ethernet 1 Port+RS232 8 Ports with SECS-I
<->HSMS Bridge(Parameter method)
ETOS-150-HSMS
SECS/HSMS통신
Ethernet 1 Port+RS232 2 Ports + HSMS
ETOS-150-Sgate
SECS/HSMS통신
Ethernet 1 Port+RS232 2Ports + SECS <-> HSMS Bridge
ETOS-150D-HSMS
SECS/HSMS통신
Ethernet 2 Port(Redundant)+RS232 2 Ports + HSMS
ETOS-100A-S20
Main
RS232 2 Ports
ETOS-100A-S02
Main
RS422 2 Ports
ETOS-100A-S11
Main
RS232 1 Port , RS422 1 Port
ETOS-100A-E20
Main
Ethernet 1 Port,RS232 2 Ports
ETOS-100A-E02
Main
Ethernet 1 Port,RS422 2 Ports
ETOS-100A-E11
Main
Ethernet 1 Port,RS232 1 Ports , RS422 1 Port
ETOS-100D-E20
Main
Ethernet 2 Ports, Redundant RS232 2 Ports
ETOS-100D-E02
Main
Ethernet 2 Ports, Redundant RS422 2 Ports
ETOS-100D-E11
Main
Ethernet 2 Ports,RS232 1 Ports , RS422 1 Port
ETOS
Ordering Information
ETOS-300D
Classification
Model
ETOS-1000-RCP
26
ETOS
Ordering Information
Product
ETOS-100
Option
Module
ETOS-50A
ETOS-Profibus
ETOS-CC-Link
Ordering Information
ETOS-DNA-PLUS
ETOS-TS
[*1]
[*2]
27
Model
Classification
Specification
ETOS-OPT-232
Serial Option
ETOS100/150 Series Option RS232 2 Ports
ETOS-OPT-422
Serial Option
ETOS100/150 Series Option RS422 2 Ports
ETOS-OPT-Fnet
Fieldbus Option
ETOS100/150 Series Option LSIS Fnet
ETOS-OPT-DPM
Fieldbus Option
ETOS100/150 Series Option Profibus-DP master
ETOS-50A-S20
Main
RS232 2 Ports
ETOS-50A-S02
Main
RS422 2 Ports
Main
RS422 1 Port(COM1), RS232 1 Port(COM2)
ETOS-50A-E10
Main
Ethernet 1 Port, RS232 1 Port
ETOS-50A-E01
Main
Ethernet 1 Port, RS422 1 Port
ETOS-50A-S11
[*1]
ETOS-50A-Sgate
Main
Ethernet 1 Port, RS232 1 Port (Convert SECS-I to HSMS)
ETOS-DPS-S02
Main
Profibus-DP Slave ,RS422/485 2 Ports
ETOS-DPS-S20
Main
Profibus-DP Slave ,RS432 2 Ports
ETOS-CCS-E00
Main
CC-Link Slave , Ethernet 1ch
ETOS-CCS-S02
Main
CC-Link Slave ,RS232/485 2 Ports
ETOS-CCS-S20
Main
CC-Link Slave ,RS232 2 Ports
ETOS-DNA-PLUS-S20 Main(Classify by port)
Serial (RS232) 2 Ports
ETOS-DNA-PLUS-S02
Main
Serial (RS422) 2 Ports
ETOS-DNA-PLUS-S40
Main
Serial (RS232) 4 Ports
ETOS-DNA-PLUS-S04
Main
Serial (RS422) 4 Ports
ETOS-DNA-PLUS-S22
Main
Mixed Serial RS232 2 Ports, RS422 2 Ports
ETOS-DNA-PLUS-E20
Main
Ethernet 1 Port, RS232 2 Ports
ETOS-DNA-PLUS-E02
Main
Ethernet 1 Port, RS422 2 Ports
ETOS-DNA-PLUS-E40
Main
Ethernet 1 Port, RS233 4 Ports
ETOS-DNA-PLUS-E04
Main
Ethernet 1 Port, RS422 4 Ports
ETOS-DNA-PLUS-E22
Main
Ethernet 1 Port, RS232 Ports , RS422 2 Ports
DNA-PLUS-OPT-RY16
Input and Output Option
Relay Output 16 Points
DNA-PLUS-OPT-TR16
Input and Output Option
Tr Output 16 Points
DNA-PLUS-OPT-DC16
Input and Output Option
DC24V Input 16 Points
DNA-PLUS-OPT-DT15
Input and Output Option
(Classify by I/O)
TR Output 7 Points / DC 24V Input 8 Points
(for combined input and output)
DNA-PLUS-OPT-DR16
Input and Output Option
Relay Output 8 Points / DC24V Input 8 Points
(for combined input and output)
DNA-PLUS-OPT-AD4
Input and Output Option
Analog Input 4 ch[*2]
ETOS-TS-F0
Main
Ethernet 2 Port,RS232 16 Ports, Single Power
ETOS-TS-0F
Main
Ethernet 2 Port,RS422 16 Ports, Single Power
DNA-TS-80
Main
Ethernet 2 Port,RS232 8 Ports, Single Power
DNA-TS-08
Main
Ethernet 2 Port,RS422 8 Ports, Single Power
DNA-TS-FOR
Main
Ethernet 2 Port,RS232 16 Ports, Redundant Power
DNA-TS-OFR
Main
Ethernet 2 Port,RS422 16 Ports, Redundant Power
DNA-TS-80R
Main
Ethernet 2 Port,RS232 8 Ports, Redundant Power
DNA-TS-08R
Main
Ethernet 2 Port,RS422 8 Ports, Redundant Power
On serial 2-ports, Com1 is fixed to RS 422/485, and Com2 is fixed to RS 232
Refers Analog specification of ETOS-DNA
ETOS
ETOS
Wiring Diagram
Communication Port Pin Assignation
C o m m un i c a t i o n C l a s s i f i c a t i o n
Pin Number
[*1]
1
2
3
4
5
6
7
8
9
RS-233
CD
RXD
TXD
DTR
S.G
DSR
RTS
CTS
-
RXD+
TXD+
-
S.G
-
TXD-
RXD-
-
-
S.G
-
-
-
RD-
-
-
-
RS-422
-
RS-485 [*1]
-
Ethernet
TD+
TRX+
-
TRX-
TD-
RD+
-
-
TRX+
-
-
-
-
TRX-
-
DA
DB
DG
Shield
-
-
-
-
-
-
-
-
-
TRX+
TRX-
-
-
Profibus
CC-Link
Fnet
-
To use as RS485 is should be shorted each 2nd pin and 3rd pin, 7th pin and 8th pin
Communication Port connector Spec
ETOS-50
ETOS-100A/100D ETOS-200
ETOS-150/150D
ETOS-300
ETOS-1000 ETOS-300D
ETOS-TS
ETOS
- DNA
- PLUS
ETOSCC-Link
ETOS-Profibus
RS-232
RS-422
RJ-45(8PIN)
DSUB-9(FeMale)
RS-485
Ethernet
RJ-45(8PIN)
Profibus
-
CC-Link
Fnet
DSUB-9
-
-
-
-
-
DSUB-9
-
-
-
-
-
-
Plug(4Pin)
-
-
DSUB-9
-
-
-
-
-
-
Dimension [Unit : mm]
ETOS-1000
19” RACK 6U/ Cabinet Wall Mount
Front View
Top View
Side View
Wiring Diagram/Dimension
C o m m un i c a t i o n C l a s s i f i c a t i o n
ETOS Series
Classification
ETOS-300/300D
Front View
Top View
ETOS-300
ETOS
28
ETOS
Dimension [Unit : mm]
ETOS-200
19” RACK 2U/ Cabinet Wall Mount
Front View
Top View
Side View
ETOS-150/ 100
Top View (Wall Mount)
Side View
Front View
Dimension
ETOS-50
Top View
Side View (Din Rail)
Front View
ETOS-Profibus
Front View (Wall Mount)
29
Side View (Din Rail)
Rear View
ETOS
ETOS
Dimension [Unit : mm]
ETOS-CC-Link
Front View (Wall Mount)
Side View (Din Rail)
Rear View
ETOS-DNA-PLUS
Front View
Side View
(Din Rail)
Top View (Wall Mount)
Dimension
ETOS-TS
Front View
Top View
ETOS-300
Communication Connector Shape Diagrams
RJ-45
Connector
D-SUB
9-PIN(Female)
D-SUB
9-PIN(Male)
PLUG(4-PIN)
CC-Link
ETOS
30
AC&T System Co.,Ltd.
http://www.acnt.co.kr
Phone : +82-31-386-7795 (Ext. 401)
Fax
: +82-31-386-7796
Adress : A607 ACROTOWER,1591, Gwanyang-dong, Dongan-gu, Anyang-si,