Ionpure® LabXT Laboratory Electrodeionization (CEDI) Modules
Transcription
Ionpure® LabXT Laboratory Electrodeionization (CEDI) Modules
Ionpure® LabXT Laboratory Electrodeionization (CEDI) Modules The LabXT module is designed with proven Ionpure® continuous electrodeionization (CEDI) technology to produce laboratory grade high purity water. These CEDI modules provide a reliable and cost effective replacement option for Millipore’s Elix® module equipped Laboratory Water Systems. Expand your laboratory component and service related capabilities with proven Ionpure® CEDI technologies. Each LabXT module is designed specifically for the flow rate and water quality requirements of the following Elix® systems. Millipore Elix® System Ionpure® LabXT Replacement Module Module Flow Rate Elix 3 IP-LabXT 3 3 l/h Elix 5 IP-LabXT 5 5 l/h Elix 10 IP-LabXT 10 10 l/h LabXT Series Features Low extractable natural polysulfone construction Packaged and assembled with connections and wiring for direct Elix® module replacement Guaranteed leak free operation Proven performance from the worldwide leaders in electrodeionization technologies Effective 4-pass flow design ANODE END 3 LPH ANODE END 5 & 10 LPH .88 22.2 TYP BLOCKED BLOCKED CATHODE END 3, 5 & 10 LPH "A" .59 15 6 MM X 6 MM TUBE FITTING TYP 1.87 47.5 MOUNTING HOLE BLOCKED CONC. FEED IN BLOCKED WASTE OUT M4-.7 X 8 NEGATIVE TERMINAL SCREW 6.45 163.8 M4-.7 X 8 POSITIVE TERMINAL SCREW 6.20 157.5 10.88 276.2 13.00 330.2 12.75 323.8 5.08 129.1 CONC. FEED IN DILUTE FEED IN BLOCKED DILUTE FEED IN BLOCKED .65 16.6 PRODUCT OUT TYP .31 7.9 .59 15 CL CL 1.85 47.1 CL "B" "C" 2.23 56.6 .88 22.4 Ionpure® LabXT Laboratory Electrodeionization (CEDI) Modules Operating Environment Installation should be indoors with no direct sunlight and it should have a maximum ambient room temperature of 113°F (45°C). Materials Construction Wetted components of the LabXT module consist of: natural polysufone, ion-selective membranes, ion exchange resins, and thermoplastic elastomer. Quality Assurance Standards Each module is factory tested to meet strict Ionpure module and industry standards and is manufactured in an ISO 9001:2000 facility. The final assembled modules are factory tested to ensure interconnector and electrical integrity. Ordering Info CEDI Feed Water Specifications* Water Quality RO Permeate CEDI Feed Water Conductivity <60 µS/cm CO2 <30 ppm as CO2 Temperature 5-35 ºC Total Chlorine <0.02 ppm as Cl2 Inlet Pressure 0.5 – 1.5 bar TOC 500 ppb as C * At inlet to CEDI module CEDI Performance** Recovery 60% Flow Rate (LabXT 3, 5 and 10) 3 l/h , 5 l/h and 10 l/h Product Resistivity >5 MΩ-cm (10-15 MΩ typical) 1. Part number to use when ordering: LabXT 3 lph W3T101571 TOC (with RO pretreatment) < 30 ppb LabXT 5 lph W3T101572 Silica (SiO2) > 99.9% removal LabXT 10 lph W3T101573 ** When installed in Millipore ELIX® system 2. Each LabXT module has compatible water connections to allow for simple replacement. Physical Specifications Dimensions in (mm) 6 mm tubing connections Weight lb (kg) Module 3. Module electrical power connections are made through the included wiring harness. Siemens 10 Technology Drive Lowell, MA 01851 Phone: 866.876.3340 Depth (Includes elbows) Width LabXT 3 4.08 (103.6) 2.23 (56.6) 2.3 (1.04) LabXT 5 4.58 (116.3) 2.23 (56.6) 2.8 (1.27) LabXT 10 5.08 (129.0) 2.23 (56.6) 3.3 (1.50) © 2010 Siemens Water Technologies Corp. ION-LABXT-DS-0310 Subject to change without prior notice. Ionpure is a trademark of Siemens its subsidiaries or affiliates. Elix is a trademark of Millipore Corporation. The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. www.siemens.com/ionpure