OPHTEC

Transcription

OPHTEC
Product Line 2010
Refractive Surgery | Cataract Surgery | Trauma Surgery
CONTENT
About OPHTEC
3
Refractive Surgery 4
Artisan® Myopia & Hyperopia PIOL
Artisan® Toric PIOL Artiflex® Myopia PIOL NEW: Artiflex® Toric PIOL
Artisan® Instruments Artiflex® Instruments Equipment: Endothelial Cell Count Camera
Intacs 5
6
7
8
9
9
10
10
Cataract Surgery 11
NEW: Luna™ Aspherical Hydrophobic Acrylic IOL
12
NEW: QuadrimaX™ Aspherical Hydrophilic Acrylic IOL 13
Hydrophilic Acrylic IOLs 14
Polysiloxane IOLs 15
PMMA IOLs 16
Artisan® Aphakia IOL 17
DualTec™ IOL Injector
18
Capsular Tension Ring 19
Viscoelastics 20
Surgical Knives
21
Equipment: Pulsar 2 Minimal Stress Phaco 22
Equipment: Statim 5000 Steam Sterilizer 22
Trauma Surgery 23
Aniridia Lenses IPS® elements Patient Design Lenses Available colours
24
24
25
25
Contact
26
2
www.ophtec.com
OPHTEC
| About OPHTEC
about OPHTEC
Founded in 1983 in Groningen, The Netherlands, Ophtec is a
privately held innovative medical device manufacturer that
provides unique and proprietary, high quality intraocular lenses,
and a complete line of ophthalmic surgical devices for:
Refractive Surgery | Cataract Surgery | Trauma Surgery
Ophtec distributes its products worldwide through a network of knowledgeable
distributors. We aim for the highest standard of service by long term experience
in helping surgeons to find solutions for their challenging cases, multilingual
assistance and prompt delivery. Our knowledge and experience is available for you.
Ophtec expands on ideas that originate in the operating theatre. Ideas to improve
a procedure or surgical technique must be developed in such a way that it does
justice to the original intention. Ophtec is continuously setting trends in ophthalmic
surgical product innovation thanks to its close contact with internationally leading
ophthalmic surgeons and its own ophthalmic clinic.
It’s all about being the right hand of the
surgeon with a focus on perfection.
3
www.ophtec.com
OPHTEC | Refractive Surgery
4
OPHTEC
| Refractive Surgery IOLs
artisan® Myopia & Hyperopia PIOL
First FDA approved, # 1 Phakic IOL worldwide
ARTISAN® has passed the test of time by filling the need for those who seek a predictable and
stable solution for the surgical correction of myopia, hyperopia and astigmatism.
ARTISAN® Myopia
| Model 206
Material:
Perspex CQ-UV
Optic Ø: 5.0 mm
Overall Ø: 8.5 mm
artisan® instruments
OD 125 ARTISAN® / ARTIFLEX® Disposable Enclavation Needle
Dioptric Powers: -1.0 D to -23.5 D (0.5 increments)
DO2 40 ARTISAN® Enclavation Forceps
ARTISAN® Myopia
| Model 204
Material:
Perspex CQ-UV
Optic Ø: 6.0 mm
Overall Ø: 8.5 mm
D02 70 ARTISAN® Implantation Forceps Refractive, Long
D02 72 ARTISAN® Implantation Forceps Refractive, Short
D06 41 ARTISAN® Lens Manipulator Standard, straight
Dioptric Powers: -1.0 D to -15.5 D (0.5 increments)
ARTISAN® Myopia small
| Model 202
Material:
Perspex CQ-UV
Optic Ø: 5.0 mm
Overall Ø: 7.5 mm
Dioptric Powers: -1.0 D to -23.5 D (0.5 increments)
ARTISAN® Hyperopia
| Model 203
Material:
Perspex CQ-UV
Optic Ø: 5.0 mm
Overall Ø: 8.5 mm
ARTISAN® & ARTIFLEX® Training Course
To obtain the best results, OPHTEC continuously conducts specialized
training courses throughout the world to develop and maintain surgical
skills. OPHTEC’s condition to use the product correctly is to provide
ARTISAN® & ARTIFLEX® IOLs only to certified professionals.
Dioptric Powers: +1.0 D to +12.0 D (0.5 increments)
For more information on training courses send an e-mail to
[email protected], or call +31 50 525 1944.
5
www.ophtec.com
OPHTEC
| Refractive Surgery IOLs
artisan® Toric PIOL
The # 1 Toric Phakic IOL worldwide
The ARTISAN® Toric PIOL completes the ARTISAN® family with a lens that corrects astigmatism.
The lens can be fixated on the proper cylinder axis. Once fixated the lens cannot rotate or decenter.
ARTISAN® Toric PIOL
| Model 110, 120, 130, 140
Material:
Perspex CQ-UV
Optic Ø: 5.0 mm
Overall Ø: 8.5 mm
artisan® instruments
OD 125 ARTISAN® / ARTIFLEX® Disposable Enclavation Needle
DO2 40 ARTISAN® Enclavation Forceps
D02 70 ARTISAN® Implantation Forceps Refractive, Long
D02 72 ARTISAN® Implantation Forceps Refractive, Short
D06 41 ARTISAN® Lens Manipulator Standard, straight
Positive Cylinder Range
Negative Cylinder Range
Lens model
Axis
Lens model
Axis
110**1W
0°
130**1W
0°
120**1W
90°
140**1W
90°
Cylinder
Power
Minimal
Sphere
Power
Maximal
Sphere
Power
Sphere
Power
Increments
Cylinder
Power
Minimal
Sphere
Power
Maximal
Sphere
Power
Sphere
Power
Increments
D
D
D
D
D
D
D
D
1.0
-23.0
6.5
0.5
-1.0
-22.0
7.5
0.5
1.5
-23.0
6.5
0.5
-1.5
-21.5
8.0
0.5
2.0
-23.0
6.5
0.5
-2.0
-21.0
8.5
0.5
2.5
-23.0
6.5
0.5
-2.5
-20.5
9.0
0.5
3.0
-23.0
6.5
0.5
-3.0
-20.0
9.5
0.5
3.5
-23.0
6.5
0.5
-3.5
-19.5
10.0
0.5
4.0
-23.0
6.5
0.5
-4.0
-19.0
10.5
0.5
4.5
-23.0
6.5
0.5
-4.5
-18.5
11.0
0.5
5.0
-23.0
6.5
0.5
-5.0
-18.0
11.5
0.5
5.5
-23.0
6.5
0.5
-5.5
-17.5
12.0
0.5
6.0
-23.0
6.5
0.5
-6.0
-17.0
12.5
0.5
6.5
-23.0
6.5
0.5
-6.5
-16.5
13.0
0.5
7.0
-23.0
6.5
0.5
-7.0
-16.0
13.5
0.5
7.5
-23.0
6.5
0.5
-7.5
-15.5
14.0
0.5
6
www.ophtec.com
OPHTEC
| Refractive Surgery IOLs
artiflex® Myopia PIOL
Next Generation of Iris Fixated IOLs
ARTIFLEX® has a foldable lens body thus permitting a small incision.
Therefore ARTIFLEX® offers a better predictability and faster recovery.
ARTIFLEX® Myopia
Optic Material: | Model 401
Polysiloxane
Haptic Material: Perspex CQ-UV
Body Ø: 6.0 mm
Overall Ø: 8.5 mm
Edge Design:
Polynomial
ARTIFLEX® in the eye
Dioptric Powers: -2.0 D to -14.5 D
(0.5 D increments)
artiflex® instruments
ARTIFLEX® Postoperative Result
OD 125 ARTISAN® / ARTIFLEX® Disposable Enclavation Needle
OD 110 ARTIFLEX® Disposable Insertion Spatula
OF 106 ARTIFLEX® Reusable Implantation Forceps Right
OF 105 ARTIFLEX® Reusable Implantation Forceps Left
OF 115 ARTIFLEX® Manipulator
OF 150 ARTIFLEX
®
Instruments Kit
Contains:
OF 105 ARTIFLEX® Reusable Implantation Forceps Left
OF 106 ARTIFLEX® Reusable Implantation Forceps Right
OF 115 ARTIFLEX® Manipulator
7
www.ophtec.com
OPHTEC
| Refractive Surgery
The Jump to Perfection in Refractive Surgery
NEW
ARTIFLEX® Toric PIOL
Specifications
Overall diameter:
8.5 mm
Body diameter:
6 mm
Iris claw® design / iris fixation
Optic material:
Hydrophobic Polysiloxane
Claw material:
Perspex CQ-UV
Refractive index:
1.43
Cross Flow design:
4 lateral side ports
Available
powers:
The dioptric power range
incudes a spherical correction
from -1.0 to -13.5 diopters in
combination with a cylinder
correction from -1.0 to -5.0
diopters.
• ensures fixed and precise positioning on marked axis
• no breakdown in blood-aqueous barrier
• no rotation postoperatively
Small incision
• 3.2 mm
Long term safety
• over 30 years of experience
Large optical zone
• 6.0 mm body
Optimal clearance from:
• crystalline lens
• iris
• endothelium
8
www.ophtec.com
OPHTEC
| Refractive Surgery Instruments
artisan® instruments
OD 125 ARTISAN® / ARTIFLEX® Disposable Enclavation Needle
DO2 40 ARTISAN® Enclavation Forceps
D02 70 ARTISAN® Implantation Forceps Refractive, Long
D02 72 ARTISAN® Implantation Forceps Refractive, Short
D06 41 ARTISAN® Lens Manipulator Standard, straight
artiflex® instruments
OD 125 ARTISAN® / ARTIFLEX® Disposable Enclavation Needle
OD 110 ARTIFLEX® Disposable Insertion Spatula
OF 150 ARTIFLEX
®
Instruments Kit
OF 106 ARTIFLEX® Reusable Implantation Forceps Right
OF 105 ARTIFLEX® Reusable Implantation Forceps Left
Contains:
OF 105 ARTIFLEX® Reusable Implantation Forceps Left
OF 106 ARTIFLEX® Reusable Implantation Forceps Right
OF 115 ARTIFLEX® Manipulator
OF 115 ARTIFLEX® Manipulator
99
www.ophtec.com
www.ophtec.com
OPHTEC
| Refractive Surgery Equipment
endothelial cell count
SEAEAGLE® ENDOTHELIUM
Specular microscope for non-contact live images of corneal endothelium-layer.
Features
• True non contact principle
• Live endothelium image
• Automatic selection of good endothelium images
• Evaluation is possible at any time
• Digital image/data archiving (network & practice software)
• 1 center + 4 peripheral measure points
Distribution in Belgium and The Netherlands only
intacs®
Clear, Micro-thin Inserts placed in the Cornea
Intacs reshape the curvature of the cornea from within,
working with the natural shape of an eye to correct mild nearsightedness.
Features
Patients should be 21 years of age or older and have a
cycloplegic spherical equivalent refraction between -1.00
and -4.50 diopters. The cylindrical correction should be
no more than 1 diopter.
Intacs consist of two PMMA segments that are inserted
into the mid peripheral stroma, outside the central
optical zone, the area most critical for clear vision. The
result is flexible correction, designed to be permanent
and adjustable. It can be reversed, if desired, upon
removal of the product.
The procedure for Intacs is performed in no more than
30 minutes per eye, in an outpatient setting and under
topical anesthesia.
Distribution in Belgium and The Netherlands only
10
www.ophtec.com
OPHTEC | Cataract Surgery
11
OPHTEC
| Cataract Surgery
NEW
Luna
™
PC 620
Aspherical Hydrophobic Acrylic IOL
Ophtec advises to use this IOL in combination
with OD 660 DualTec kit 1P Acrylic 2.4
Specifications
Lens type:
One piece IOL | In the bag fixation
Biconvex | Aspherical surface
Square edge 360˚
Overall diameter:
10.40 to 10.90 mm*
Body diameter:
5.7 / 6.0 mm*
Lens material:
Hydrophobic Acrylic
Haptics:
4 closed loops
Angulation
10˚
Refractive index:
1.48
AC depth:
5.55 mm
A-constant:
119.0 (ultrasound)
119.4 (laser interference)
Available powers:
+10.0 D to +30.0 D (1.0 D increments)
+14.5 D to +25.5 D (0.5 D increments)
(including disposable DualTec SoftTip Injector
+ 2.4 cartridge):
Perfect implantation through 2.5 mm
The Luna™ Aspherical Hydrophobic Acrylic IOL and the
DualTec™ SoftTip IOL Injector are designed to make
implantation through a 2.5 mm incision as easy as
possible. It is as simple as this: However the lens is
implanted, it will always be correct.
Advise: Set DualTec™ to ‘TURN’ for Luna™
• ProGel®
ProGel® combines high viscosity and high elasticity with
high molecular weight. It provides protection of endothelial
cells and allows tissue manoeuvres whenever this is needed
in cataract surgery.
* Depends on diopter
12
www.ophtec.com
OPHTEC
| Cataract Surgery
NEW
QuadrimaX
™
PC 545
Aspherical Hydrophilic Acrylic IOL
Ophtec advises to use this IOL in combination
with OD 660 DualTec kit 1P Acrylic 2.4
Specifications
Lens type:
One piece IOL | In the bag fixation
Biconvex | Aspherical surface
Square edge 360˚
Overall diameter:
10.50 to 11.0 mm*
Body diameter:
5.7 / 6.0 mm*
Lens material:
Hydrophilic Acrylic
Haptics:
4 closed loops
Angulation
8˚
Refractive index:
1.46
AC depth:
4.96 mm
A-constant:
118.0 (ultrasound)
118.5 (laser interference)
Available powers:
+10.0 D to +30.0 D (1.0 D increments)
+14.5 D to +25.5 D (0.5 D increments)
(including disposable DualTec SoftTip Injector
+ 2.4 cartridge):
Perfect implantation through 2.5 mm
The QuadrimaX™ Aspherical Hydrophilic Acrylic IOL and
the DualTec™ SoftTip IOL Injector are designed to make
implantation through a 2.5 mm incision as easy as possible.
It is as simple as this: However the lens is implanted, it will
always be correct.
• ArtiVisc®, ArtiViscPlus® & ProGel®
ArtiVisc® & ArtiViscPlus® and ProGel® combine high viscosity
and high elasticity with high molecular weight. They provide
protection of endothelial cells and allow tissue manoeuvres
whenever this is needed in cataract surgery.
* Depends on diopter
13
www.ophtec.com
OPHTEC
| Cataract Surgery IOLs
hydrophilic acrylic iols
The combination of the best materials and a choice of designs, makes the hydrophilic acrylic range
complete. These one- and three piece lenses can be implanted through the smallest incisions.
The IOLs are manufactured using the latest technology, ensuring flexibility and high accuracy.
One Piece IOLs | In the bag Fixation
Model 511
Body: 6.0 mm | biconvex
square edge
Haptics: Overall Ø: QuadrimaX™
| Aspherical | Model 545
Mod. C-loop | 5˚angulation
Body: 5.7 - 6.0 mm | biconvex
aspherical surface
square edge 360˚
12.5 mm
Haptics: 4 closed loops | 8˚angulation
A-Constant: 117.8
Overall Ø: 10.5 - 11.0 mm
AC Depth: 4.8 mm
A-Constant: 118.0 (ultrasound)
118.5 (laser interference
AC Depth: 4.96 mm
Dioptric Powers: -7.0 D to 35.0 D (1.0 increments)
ErgomaX™
10.5 D to 29.5 D (0.5 increments)
Dioptric Powers: 10.0 D to 30.0 D (0.5 increments)
14.5 D to 25.5 D (0.5 increments)
| Model 525
MonomaX™
| Model 550
Body: 6.0 mm | biconvex
Body: 6.5 mm | biconvex
Aspherical sharp edge
Haptics: Mod. C-loop | 5˚angulation
Haptics: 0˚angulation
Edge design:
Aspherical sharp edge
Overall Ø: 10.5 mm
Overall Ø: 12.5 mm
A-Constant: 118.0
A-Constant: 118.0
AC Depth: 5.0 mm
AC Depth: 5.0 mm
Dioptric Powers: -7.0 D to 35.0 D (1.0 increments)
Dioptric Powers: -5.0 D to 35.0 D (1.0 increments)
10.5 D to 29.5 D (0.5 increments)
10.5 D to 29.5 D (0.5 increments)
Three Piece IOLs | In the bag and Sulcus Fixation
TrimaX™
| Model 530
Body: 6.0 mm | biconvex | square edge
26% Hydrophilic Acrylic
Haptics: Mod. C-loop | 5˚angulation
Blue PES
Overall Ø: 13.0 mm
A-Constant: 117.8
AC Depth: 4.8 mm
Dioptric Powers: -5 D to 35.0 D (1.0 increments)
10.5 D to 29.5 D (0.5 increments)
14
www.ophtec.com
OPHTEC
| Cataract Surgery IOLs
polysiloxane iols
Reliable Flexibility
This third generation of high quality, long term experience IOLs is made from an optically clear silicone elastomer
with a covalently bound UV absorber. This material offers a light transmission of 90% in the visible spectrum
Three Piece IOLs | In the bag Fixation
Model 410 |
Classic Series™
Model 440 |
Orange Series™
Optic: 5.8 mm | Clear optic
Optic: 5.8 mm | Biconvex | Square edge
Biconvex | Square edge
Optic Material:
Clear Polysiloxane elastomer
Loops: Mod. C-loop | 5˚angulation
with covalently bound Orange UV
Blue PMMA
absorber
Overall Ø: 12.5 mm
Loops: C-fit loop | 10˚angulation
A-Constant: 117.5
Brown PMMA
AC Depth: 4.7 mm
Overall Ø: 12.5 mm
A-Constant: 118.0
AC Depth: 5.0 mm
Dioptric Powers: -5.0 D to 30.0 D (0.5 increments)
Dioptric Powers: -5.0 D to 30.0 D (0.5 increments)
Model 415 |
Classic Series™
Optic: 5.8 mm | Clear optic
Biconvex | Square edge
Loops: Mod. C-loop | 5˚angulation
Blue PMMA
Overall Ø: 13.5 mm
A-Constant: 117.5
AC Depth: 4.7 mm
Dioptric Powers: -5.0 D to 30.0 D (0.5 increments)
Model 430 |
Elite Series™
Optic: 5.8 mm | Clear optic
Biconvex | Square edge
Loops: C-fit loop | 10˚angulation
Brown PMMA
Overall Ø: 12.5 mm
A-Constant: 118.0
AC Depth: 5.0 mm
Dioptric Powers: -5.0 D to 30.0 D (0.5 increments)
1515
www.ophtec.com
OPHTEC
| Cataract Surgery IOLs
pmma iols
A Surgeon’s Eye for Quality
A unique combination of craftsmanship, quality control, care and dedication
results in products of incomparable quality.
In the Bag Fixation |
Model 283
In the Bag Fixation |
Model 288
Optic: 5.0 mm | biconvex
Optic: 6.0 mm | biconvex
Loops: C-fit loop | 10˚angulation
Loops: Short C-loop | 10˚angulation
Overall Ø: 12.0 mm
Overall Ø: 12.75 mm
A-Constant: 118.5
A-Constant: 118.2
AC Depth: 4.9 mm
AC Depth: 4.8 mm
Dioptric Powers: -5.0 D to 30.0 D (1.0 increments)
Dioptric Powers: -5.0 D to 34.0 D (1.0 increments)
In the Bag Fixation |
10.5 D to 29.5 D (0.5 increments)
Model 264
Sclera Fixation
10.5 D to 29.5 D (0.5 increments)
| Model 279
5.5 mm | biconvex
Optic: 7.0 mm | biconvex
Loops: Short C-loop | 10˚angulation
Loops: C-loop | 10˚angulation
Overall Ø: 12.0 mm
2 Scleral Fixation holes
A-Constant: 118.0
Overall Ø: 13.75 mm
AC Depth: 4.7 mm
A-Constant: 118.5
Dioptric Powers: -5.0 D to 30.0 D (1.0 increments)
AC Depth: 4.9 mm
Dioptric Powers: 10.0 D to 30.0 D (1.0 increments)
Optic: 10.5 D to 29.5 D (0.5 increments)
14.5 D to 29.5 D (0.5 increments)
| Model 260
Sulcus Fixation
| Model 292
Angle Supported
Optic: 6.5 mm | biconvex
Optic: 6.0 mm | Convex-plano
Loops: Mod. C-loop | 10˚angulation
Loops: Step-vaulted
Overall Ø: 13.75 mm
Overall Ø: 12.75 mm
A-Constant: 118.5
A-Constant: 114.2
AC Depth: 4.9 mm
AC Depth: 2.8 mm
Dioptric Powers: 0.0 D to 30.0 D (1.0 increments)
Dioptric Powers: 10.0 D to 26.0 D (1.0 increments)
10.5 D to 29.5 D (0.5 increments)
14.5 D to 23.5 D (0.5 increments)
>>
16
www.ophtec.com
OPHTEC
| Cataract Surgery IOLs
artisan® aphakia
#1 Backup Lens in complicated Cataract Cases
Based on the long term experience of Iris Fixation, the ARTISAN® Aphakia IOL is
a predictable, safe, high precision implant, that corrects the eye when it is not
correctable by other means. Pediatric lenses are available upon request for juvenile
or congenital cataract cases.
Iris Fixation | Model 205 ARTISAN® Aphakia
Optic: 5.4 mm
Haptics: Iris Claw®
Overall Ø: 8.5 mm
A-Constant: 115.0 (ultrasound)
115.7 (laser interference)
AC Depth: OD 125 ARTISAN® / ARTIFLEX® Disposable Enclavation Needle
3.3 mm
Dioptric Powers: 2.0 D to 30.0 D (1.0 increments)
14.5 D to 24.5 D (0.5 increments)
D02 74 ARTISAN® Implantation Forceps Standard
Also available:
ARTISAN® Pediatric Aphakia
4.4/6.5 and 4.4/7.5
Designed for small eyes
ARTISAN® Training Course
To obtain the best results, OPHTEC continuously conducts specialized
training courses throughout the world to develop and maintain surgical
skills. OPHTEC’s condition to use the product correctly is to provide
ARTISAN® IOLs only to certified professionals.
For more information on training courses send an e-mail to
[email protected], or call +31 50 525 1944.
17
www.ophtec.com
OPHTEC
| Cataract Surgery Injectors
dualtec™ softtip iol injector
The DualTec™ SoftTip IOL Injector is a single use lens injector for one piece
hydrophilic acrylic IOLs with 2.5 mm incision. The special feature to switch over
from push to turn function and reverse gives perfect ergonomy for a precise
implantation.
OD 660 DualTec Kit 1P Acrylic 2.4
DualTec SoftTip Injector + 2.4 cartridge
for 1 piece acrylic IOLs
P
2.5 mm incision
One piece hydrophilic acrylic IOLs can be implanted
through a 2.5mm incision using the OD660
P
switch for freedom of choice:
push or turn
DualTec™ Kit consisting of a single use DualTec™
SoftTip IOL Injector and Locking Wing System™
Micro Tip Cartridges.
perfect ergonomy for precise implantation
A hard tip version is available for three piece IOLs;
P
single use
OD 640 DualTec™ kit 3P Polysiloxane 3.0
safe, hygienic, constant quality
OD 650 DualTec™ kit 3P Acrylic 3.0
P
microtip cartridge
convenient cartridge loading
Reusable Systems
Single Use Systems
Injector + Cartridge (box of 10)
• OD 640 DualTec kit 3P Polysiloxane 3.0
• OD 650 DualTec kit 3P Acrylic 3.0
OD230 Foldable Lens Injector | Push
Technique
OD233 Foldable Lens Injector | Rotating
• OD 660 DualTec kit 1P Acrylic 2.4
Cartridge (box of 10)
Technique
• OD 401 LWS Cartridge 3P Polysiloxane 3.0
• OD 501 LWS Cartridge 3P Acrylic 3.0
• OD 521 LWS Cartridge 1P Acrylic 2.4
18
www.ophtec.com
OPHTEC
| Cataract Surgery
capsular tension rings
Flexible Insertion, Stable Result
Highly flexible due to the compression molding technology.
These PMMA Capsular Tension Rings are indicated for
the stabilization of weakened, broken or missing zonules
preventing IOL decentration after capsular shrinking.
Capsular Tension Ring |
Model 275
Capsular Tension Ring |
12/10
Model 276
13/11
Compression: From 12 mm to 10 mm
Compression: From 13 mm to 11 mm
Material: PMMA | Flexible Ring
Material: PMMA | Flexible Ring
Available in: Clear and brown PMMA
Available in: Clear and brown PMMA
Overall Ø: 12 mm
Overall Ø: 13 mm
Recommended to be used in combination
with the ON 385 EASY Control™ Micro Inserter
19
www.ophtec.com
OPHTEC | Cataract Surgery IOLs
viscoelastics
ArtiVisc®, ArtiViscPlus® & ProGel®
ArtiVisc® & ArtiViscPlus® (sodium hyaloronic acid), combine high viscosity and high
elasticity with high molecular weight.
ArtiVisc(Plus)®
• Sodium hyaluronate 1% (ArtiViscPlus®: 1.4 %)
• High molecular weight polymers (ArtiVisc®: >4 million daltons, ArtiViscPlus®: >5 million daltons)
• Viscosity (zero shear rate, 25˚C) Average 1 million cPs (ArtiViscPlus®: 3.3 million cPs)
• 27 gauge cannula
• pH 7.0 - 7.5
• Iso-osmolar 320 mOsm/kg
• Single Use
Also Available:
ProGel®
• HPMC | Hydroxy Propyl Methyl Cellulose
• Molecular weight 92 kilodalton
• Viscosity 4.5 k cPs
• Single Use
OV200 ProGel® H53.16.010 ArtiVisc® 1 %
H53.16.015 ArtiVisc®1 %
H53.16.020 ArtiViscPlus® 1.4 %
H53.16.025 ArtiViscPlus® 1.4 %
0.85 ml
0.55 ml
0.85 ml
0.55 ml
H53.16.035 ArtiVisc® CombiPack
0.55 ml
20
2.0 ml
www.ophtec.com
OPHTEC
| Cataract Surgery Instruments
surgical knives
Clear Corneal Knives
Clear Corneal Knives have been designed
specifically for clear corneal incisions.
Angled Type
OM200 2.65 mm Angled, full Handle
OM201 2.75 mm Angled, full Handle
OM202 2.85 mm Angled, full Handle
OM203 3.0 mm Angled, full Handle
OM204 3.2 mm Angled, full Handle
Implant Knives
Implant Knives are designed to create a precise
incision for lens insertion.
Straight Type
OM 248 4.0 mm Straight, full Handle
OM 249 5.2 mm Straight, full Handle
Angled Type
OM 250 4.0 mm Angled, full Handle
OM 251 5.2 mm Angled, full Handle
Precision Implant Knives
Precision Slit Knives penetrate easily while
making an accurate width incision for
optimal fit to the phacoemulsification tip.
OM 255
OM 256
OM 257
OM 258
Straight Type
2.65 mm Straight, full Handle
2.85 mm Straight, full Handle
3.00 mm Straight, full Handle
3.20 mm Straight, full Handle
OM 241
OM 242
OM 243
OM 244
OM 245
OM 246
OM 247
Angled Type
3.2 mm Angled, full Handle, bevel up
3.5 mm Angled, full Handle, bevel up
3.75 mm Angled, full Handle, bevel up
5.2 mm Angled, full Handle, bevel up
5.5 mm Angled, full Handle, bevel up
5.7 mm Angled, full Handle, bevel up
6.0 mm Angled, full Handle, bevel up
Spoon Knives
Slit Knives
Slit Knives allow straight, smooth penetration
without tissue drag.
OM 259
OM 260
OM 261
OM 262
OM 263
OM 264
OM 265
OM 266
Type
Spoon Knife, angled, double
bevel, 320° cutting edge
Spoon Knife, angled, double
bevel, 320° cutting edge
Straight
3.5 mm
Angled Type
OM 269 2.5 mm Straight, full Handle,
double Bevel
OM 270 2.65 mm Straight, full Handle,
double Bevel
OM 271 2.8 mm Straight, full Handle,
double Bevel
OM 272 3.0 mm Straight, full Handle,
double Bevel
OM 273 3.2 mm Straight, full Handle,
double Bevel
OM 274 3.5 mm Straight, full Handle,
double Bevel
Straight
2.65 mm
3.0 mm
3.2 mm
Angled
OM 278 3.0 mm
OM 279 3.2 mm
Type
70 ° Angled, full
Handle, Bevel up
Stab Knives are heat-tempered to provide a
strong, true point for easy penetration during
initial stab incisions.
OM 225
OM 226
OM 227
OM 228
Straight
15°
22,5°
30°
45°
Type
Straight , Full Handle
Straight , Full Handle
Straight , Full Handle
Straight , Full Handle
Crescent Design Knives - Straight
Type
Straight, full Handle
Straight, full Handle
Straight, full Handle
Crescent Knives provide consistent sharpness,
which nearly eliminates tissue drag. Ideal knives
for creating a smooth scleral shelf to promote a
self-sealing wound.
Type
Straight, full Handle,
double Bevel
Straight, full Handle,
double Bevel
Type
OM 290 Straight, full handl
Needle Blade
Angled
OM 278 3.0 mm
The unique 320° cutting surface and ultra-thin
blade enhance precision cutting capabilities where OM 279 3.2 mm
multi-directional techniques are used.
Angled
OM 310 3.2 mm
OM 311 3.0 mm
Slit Knives with parallel sides are designed to hold
tissue at the desired width while entering and
exiting the wound.
Angled Type
2.5 mm Straight, full Handle, Bevel up
2.65 mm Straight, full Handle, Bevel up
2.75 mm Straight, full Handle, Bevel up
2.85 mm Straight, full Handle, Bevel up Special Angled
3.0 mm Straight, full Handle, Bevel up OM 267 3.2 mm 3.2 mm Straight, full Handle, Bevel up 3.5 mm Straight, full Handle, Bevel up
5.1 mm Straight, full Handle, Bevel up Stab Knives
Type
OM 268 Straight, full Handle,
double Bevel
OM 275
OM 276
OM 277
Slit Knives - Parallel Sides
Special Angled
Type
Straight, full Handle,
double Bevel
Straight, full Handle,
double Bevel
Paracentesis Knife
Straight Type
OM 302 1.0 mm Paracentesis Knife, straight
21
OM 291
OM 292
OM 293
Type
Angled, full handle, Bevel up
Angled, full handle, Bevel down
Angled, full handle, double Bevel
Vitrectomy Knives
Vitrectomy Knives create small, precise access
incisions which help prevent leakage around
probes and other posterior segment instruments.
OM 320
OM 321
OM 322
Type
Vitrectomy Knife
Vitrectomy Knife Vitrectomy Knife, angle
Gauge
19 Gauge
20 Gauge
20 Gauge
www.ophtec.com
OPHTEC
| Cataract Surgery Instruments / Equipment
Clear Corneal Trephines
Ophtec’s Corneal Trephine has special cutting characteristics. Due to the extreme sharpness,
the incision causes less deformation and distortion than usual and gives no wedge formation.
Code
OT 16600
OT 16625
OT 16650 OT 16675 OT 16700 OT 16725 OT 16750 OT 16775 OT 16800 OT 16825 OT 16850 assistant
Code
OT 16875 OT 16900 OT 16925 OT 16950 OT 16975
OT 161000
OT 161050
OT 161100
OT 161150
OT 161200
Diameter
6.00 mm Ø
6.25 mm Ø
6.50 mm Ø
6.75 mm Ø
7.00 mm Ø
7.25 mm Ø
7.50 mm Ø
7.75 mm Ø
8.00 mm Ø
8.25 mm Ø
8.50 mm Ø
Diameter
8.75 mm Ø
9.00 mm Ø
9.25 mm Ø
9.50 mm Ø
9.75 mm Ø
10.00 mm Ø
10.50 mm Ø
11.00 mm Ø
11.50 mm Ø
12.00 mm Ø
pulsar2
Minimal Stress
ESP
Complete Workstation for Anterior & Posterior Segment Surgery
Modular System for the Anterior & Posterior Segment Surgery
OPTIKON Assistant Minimal Stress
OPTIKON Pulsar2 ESP
Special Features:
• EASYSYS, Ergonomic Design I/A Cassette
• U/S Programmable Emission Mode
• Co-M.I.C.S. & M.I.C.S. Product line
(Incision size range 3.2 mm - 1.0 mm)
• Hyperspeed Vitrectomy: up to 4000 cuts/min
• EMERGENCY MAX PRESSURE Command
• DOUBLE H.I.D Xenon Light Source
• 23G & 25G Product line
• Ready for ECLIPSE Video Overlay Console
• Continuous Micrometrical Stroke Length
Control & Adjustment by
Minimal Stress System
• Double Infusion: Forced Minimal IOP
& Built-in Programmable IV Pole
• Double Pump: Venturi & Peristaltic
• Programmable, Simultaneous
Double Linear Control Footpedal
• LCD Touch Screen
Special Features:
• EasySys Double Pump I/A Cassette
• Double Infusion System
• P.E.M. Programmable Emission Mode
• U/S Continuous, Pulsed, Burst
• Accessories for Co-M.I.C.S. & M.I.C.S.
• Vit Module (optional)
Distribution in the Netherlands only.
Distribution in the Netherlands only.
statim
5000 steam sterilizer
Statim 5000 Cassette Autoclave
Designed specifically for speed, Statim 5000 takes approximately 9 minutes for a complete sterilization cycle.
Benefits:
•Fast: Statim allows today’s surgeon convenient sterilization between each patient
•Safe: eliminating all biological hazards while incorporating built-in safety standard
•Gentle: protecting your investment in delicate and expensive instruments.
Distribution in the Netherlands only.
22
www.ophtec.com
OPHTEC | Trauma Surgery
23
www.ophtec.com
OPHTEC
| Trauma Surgery IOLs
aniridia lenses
Unique and Reliable
A unique solution for the correction of aniridia as well as iris coloboma. Coloured body and haptics
and additional optical correction are available for scleral, sulcus and capsular bag fixation.
HMK ANI 2
| Models 311
Optic: HMK ANI 2
4.0 mm | Models 311 without optic
Pupil Aperture: 4.0 mm
other optic diameter on request
other pupil aperture size on request
Body: 9.0 mm
Body: 9.0 mm
Loops: C-loop
Loops: C-loop
Overall Ø: 13.75 mm
Overall Ø: 13.75 mm
A-Constant: 118.5
Colours:
Brown, green, blue, black*
AC Depth: 4.9 mm
Dioptric Powers: 0.0 D and
1.0 D to 30.0 D (0.5 increments)
Colours:
Brown, green, blue, black*
ips® elements
Unlimited Solutions
The patented Iris Prosthetic System (IPS®) concept consists of different combinable elements which
are available in various colours. The IPS® elements restore the iris diaphragm and can be used in
conjunction with a posterior chamber IOL and a Capsular Tension Ring. An additional IPS® Fixation
Ring counteracts secondary shrinking of the capsular bag and stabilizes the artificial aperture.
IPS® Double Element
| Models 321, 322, 323
IPS® Single Element
| Models 324, 325
Model 321: Overal Ø: 10.5 mm
Pupil Aperture: 4.0 mm
Model 324: Overal Ø: 10.5 mm
Model 322: Overal Ø: 10.5 mm
Pupil Aperture: 4.0 mm
Pupil Aperture: 3.0 mm
Model 325: Overal Ø: 10.5 mm
Model 323: Overal Ø: 11.0 mm
Pupil Aperture: 3.0 mm
Pupil Aperture: 4.0 mm
Colours:
Brown, green, blue, black*
Colours:
Brown, green, blue, black*
IPS® Fix Ring
| Model 326
Overall Ø: 7.0 mm
Body Ø: 6.0 mm
Pupil Aperture: 3.0 mm
Colours:
Brown, green, blue, black*
Only to be used on devices with a pupil aperture of 4 mm
*Black Implants or elements are available as patient design devices.
24
www.ophtec.com
OPHTEC
| Trauma Surgery IOLs
patient design
Unique problem, unique solution
Designing and manufacturing special iris reconstruction implants for cases in which standard Iris
Reconstruction Implants do not apply. Patient Design IOLs are developed in close cooperation with
the surgeon to provide a unique problem solving solution.
ARTISAN® Pupil Occluder |
Patient Design
Optic Ø: 5.4 mm
Overall Ø: 8.5 mm
Loops:
Flexible Iris Claws®
Colours: Black
available colours
Ophtec’s Iris Reconstruction Implants are available in brown,
green and blue. These colours have been carefully chosen to
simulate the natural colouring of most eyes. Also available in
black as patient design devices.
Colour specifications of the Iris Reconstruction Implants
Warning: 1. The Anterior Segment Reconstruction Prostheses are only available
in 3 standard colours and therefore OPHTEC cannot guarantee the perfect colour
match with the fellow eye; 2. After implantation in the eye the colour of the prosthesis
might look lighter; 3. For a better evaluation and choice of the colour match, we
suggest you to consult OPHTEC representatives; 4. Black Polycarbonate is more
fragile than other (PMMA) colours.
25
www.ophtec.com
OPHTEC BV
P.O. Box 398
9700 AJ Groningen
The Netherlands
Schweitzerlaan 15
9728 NR Groningen
The Netherlands
T: +31 50 525 1944
F: +31 50 525 4386
E: [email protected]
Sales Department, The Netherlands:
T: +31 50 527 5400
F: +31 50 527 4996
OPHTEC USA, Inc.
OPHTEC España
OPHTEC South Africa
Suite 112
c/ Velázquez, 94 1º
Building 1 Unit 4, Visiomed Office Park
6421 Congress Ave.
(Zuricenter)
269 Beyers Naude Drive
Boca Raton
28006 • Madrid
Blackheath Ext.1
FL 33487
T: 900 993 174
Johannesburg, South Africa
T: +1 561 989 8767
F: 900 993 192
T: +27 825540949
F: +1 561 989 9744
E: [email protected]
F: +27 866139065
E: [email protected]
E: [email protected]
www.ophtec.com
26
©OPHTEC BV 2010 | Information in this document iswww.ophtec.com
subject to modification