OPHTEC
Transcription
OPHTEC
Product Line 2010 Refractive Surgery | Cataract Surgery | Trauma Surgery CONTENT About OPHTEC 3 Refractive Surgery 4 Artisan® Myopia & Hyperopia PIOL Artisan® Toric PIOL Artiflex® Myopia PIOL NEW: Artiflex® Toric PIOL Artisan® Instruments Artiflex® Instruments Equipment: Endothelial Cell Count Camera Intacs 5 6 7 8 9 9 10 10 Cataract Surgery 11 NEW: Luna™ Aspherical Hydrophobic Acrylic IOL 12 NEW: QuadrimaX™ Aspherical Hydrophilic Acrylic IOL 13 Hydrophilic Acrylic IOLs 14 Polysiloxane IOLs 15 PMMA IOLs 16 Artisan® Aphakia IOL 17 DualTec™ IOL Injector 18 Capsular Tension Ring 19 Viscoelastics 20 Surgical Knives 21 Equipment: Pulsar 2 Minimal Stress Phaco 22 Equipment: Statim 5000 Steam Sterilizer 22 Trauma Surgery 23 Aniridia Lenses IPS® elements Patient Design Lenses Available colours 24 24 25 25 Contact 26 2 www.ophtec.com OPHTEC | About OPHTEC about OPHTEC Founded in 1983 in Groningen, The Netherlands, Ophtec is a privately held innovative medical device manufacturer that provides unique and proprietary, high quality intraocular lenses, and a complete line of ophthalmic surgical devices for: Refractive Surgery | Cataract Surgery | Trauma Surgery Ophtec distributes its products worldwide through a network of knowledgeable distributors. We aim for the highest standard of service by long term experience in helping surgeons to find solutions for their challenging cases, multilingual assistance and prompt delivery. Our knowledge and experience is available for you. Ophtec expands on ideas that originate in the operating theatre. Ideas to improve a procedure or surgical technique must be developed in such a way that it does justice to the original intention. Ophtec is continuously setting trends in ophthalmic surgical product innovation thanks to its close contact with internationally leading ophthalmic surgeons and its own ophthalmic clinic. It’s all about being the right hand of the surgeon with a focus on perfection. 3 www.ophtec.com OPHTEC | Refractive Surgery 4 OPHTEC | Refractive Surgery IOLs artisan® Myopia & Hyperopia PIOL First FDA approved, # 1 Phakic IOL worldwide ARTISAN® has passed the test of time by filling the need for those who seek a predictable and stable solution for the surgical correction of myopia, hyperopia and astigmatism. ARTISAN® Myopia | Model 206 Material: Perspex CQ-UV Optic Ø: 5.0 mm Overall Ø: 8.5 mm artisan® instruments OD 125 ARTISAN® / ARTIFLEX® Disposable Enclavation Needle Dioptric Powers: -1.0 D to -23.5 D (0.5 increments) DO2 40 ARTISAN® Enclavation Forceps ARTISAN® Myopia | Model 204 Material: Perspex CQ-UV Optic Ø: 6.0 mm Overall Ø: 8.5 mm D02 70 ARTISAN® Implantation Forceps Refractive, Long D02 72 ARTISAN® Implantation Forceps Refractive, Short D06 41 ARTISAN® Lens Manipulator Standard, straight Dioptric Powers: -1.0 D to -15.5 D (0.5 increments) ARTISAN® Myopia small | Model 202 Material: Perspex CQ-UV Optic Ø: 5.0 mm Overall Ø: 7.5 mm Dioptric Powers: -1.0 D to -23.5 D (0.5 increments) ARTISAN® Hyperopia | Model 203 Material: Perspex CQ-UV Optic Ø: 5.0 mm Overall Ø: 8.5 mm ARTISAN® & ARTIFLEX® Training Course To obtain the best results, OPHTEC continuously conducts specialized training courses throughout the world to develop and maintain surgical skills. OPHTEC’s condition to use the product correctly is to provide ARTISAN® & ARTIFLEX® IOLs only to certified professionals. Dioptric Powers: +1.0 D to +12.0 D (0.5 increments) For more information on training courses send an e-mail to [email protected], or call +31 50 525 1944. 5 www.ophtec.com OPHTEC | Refractive Surgery IOLs artisan® Toric PIOL The # 1 Toric Phakic IOL worldwide The ARTISAN® Toric PIOL completes the ARTISAN® family with a lens that corrects astigmatism. The lens can be fixated on the proper cylinder axis. Once fixated the lens cannot rotate or decenter. ARTISAN® Toric PIOL | Model 110, 120, 130, 140 Material: Perspex CQ-UV Optic Ø: 5.0 mm Overall Ø: 8.5 mm artisan® instruments OD 125 ARTISAN® / ARTIFLEX® Disposable Enclavation Needle DO2 40 ARTISAN® Enclavation Forceps D02 70 ARTISAN® Implantation Forceps Refractive, Long D02 72 ARTISAN® Implantation Forceps Refractive, Short D06 41 ARTISAN® Lens Manipulator Standard, straight Positive Cylinder Range Negative Cylinder Range Lens model Axis Lens model Axis 110**1W 0° 130**1W 0° 120**1W 90° 140**1W 90° Cylinder Power Minimal Sphere Power Maximal Sphere Power Sphere Power Increments Cylinder Power Minimal Sphere Power Maximal Sphere Power Sphere Power Increments D D D D D D D D 1.0 -23.0 6.5 0.5 -1.0 -22.0 7.5 0.5 1.5 -23.0 6.5 0.5 -1.5 -21.5 8.0 0.5 2.0 -23.0 6.5 0.5 -2.0 -21.0 8.5 0.5 2.5 -23.0 6.5 0.5 -2.5 -20.5 9.0 0.5 3.0 -23.0 6.5 0.5 -3.0 -20.0 9.5 0.5 3.5 -23.0 6.5 0.5 -3.5 -19.5 10.0 0.5 4.0 -23.0 6.5 0.5 -4.0 -19.0 10.5 0.5 4.5 -23.0 6.5 0.5 -4.5 -18.5 11.0 0.5 5.0 -23.0 6.5 0.5 -5.0 -18.0 11.5 0.5 5.5 -23.0 6.5 0.5 -5.5 -17.5 12.0 0.5 6.0 -23.0 6.5 0.5 -6.0 -17.0 12.5 0.5 6.5 -23.0 6.5 0.5 -6.5 -16.5 13.0 0.5 7.0 -23.0 6.5 0.5 -7.0 -16.0 13.5 0.5 7.5 -23.0 6.5 0.5 -7.5 -15.5 14.0 0.5 6 www.ophtec.com OPHTEC | Refractive Surgery IOLs artiflex® Myopia PIOL Next Generation of Iris Fixated IOLs ARTIFLEX® has a foldable lens body thus permitting a small incision. Therefore ARTIFLEX® offers a better predictability and faster recovery. ARTIFLEX® Myopia Optic Material: | Model 401 Polysiloxane Haptic Material: Perspex CQ-UV Body Ø: 6.0 mm Overall Ø: 8.5 mm Edge Design: Polynomial ARTIFLEX® in the eye Dioptric Powers: -2.0 D to -14.5 D (0.5 D increments) artiflex® instruments ARTIFLEX® Postoperative Result OD 125 ARTISAN® / ARTIFLEX® Disposable Enclavation Needle OD 110 ARTIFLEX® Disposable Insertion Spatula OF 106 ARTIFLEX® Reusable Implantation Forceps Right OF 105 ARTIFLEX® Reusable Implantation Forceps Left OF 115 ARTIFLEX® Manipulator OF 150 ARTIFLEX ® Instruments Kit Contains: OF 105 ARTIFLEX® Reusable Implantation Forceps Left OF 106 ARTIFLEX® Reusable Implantation Forceps Right OF 115 ARTIFLEX® Manipulator 7 www.ophtec.com OPHTEC | Refractive Surgery The Jump to Perfection in Refractive Surgery NEW ARTIFLEX® Toric PIOL Specifications Overall diameter: 8.5 mm Body diameter: 6 mm Iris claw® design / iris fixation Optic material: Hydrophobic Polysiloxane Claw material: Perspex CQ-UV Refractive index: 1.43 Cross Flow design: 4 lateral side ports Available powers: The dioptric power range incudes a spherical correction from -1.0 to -13.5 diopters in combination with a cylinder correction from -1.0 to -5.0 diopters. • ensures fixed and precise positioning on marked axis • no breakdown in blood-aqueous barrier • no rotation postoperatively Small incision • 3.2 mm Long term safety • over 30 years of experience Large optical zone • 6.0 mm body Optimal clearance from: • crystalline lens • iris • endothelium 8 www.ophtec.com OPHTEC | Refractive Surgery Instruments artisan® instruments OD 125 ARTISAN® / ARTIFLEX® Disposable Enclavation Needle DO2 40 ARTISAN® Enclavation Forceps D02 70 ARTISAN® Implantation Forceps Refractive, Long D02 72 ARTISAN® Implantation Forceps Refractive, Short D06 41 ARTISAN® Lens Manipulator Standard, straight artiflex® instruments OD 125 ARTISAN® / ARTIFLEX® Disposable Enclavation Needle OD 110 ARTIFLEX® Disposable Insertion Spatula OF 150 ARTIFLEX ® Instruments Kit OF 106 ARTIFLEX® Reusable Implantation Forceps Right OF 105 ARTIFLEX® Reusable Implantation Forceps Left Contains: OF 105 ARTIFLEX® Reusable Implantation Forceps Left OF 106 ARTIFLEX® Reusable Implantation Forceps Right OF 115 ARTIFLEX® Manipulator OF 115 ARTIFLEX® Manipulator 99 www.ophtec.com www.ophtec.com OPHTEC | Refractive Surgery Equipment endothelial cell count SEAEAGLE® ENDOTHELIUM Specular microscope for non-contact live images of corneal endothelium-layer. Features • True non contact principle • Live endothelium image • Automatic selection of good endothelium images • Evaluation is possible at any time • Digital image/data archiving (network & practice software) • 1 center + 4 peripheral measure points Distribution in Belgium and The Netherlands only intacs® Clear, Micro-thin Inserts placed in the Cornea Intacs reshape the curvature of the cornea from within, working with the natural shape of an eye to correct mild nearsightedness. Features Patients should be 21 years of age or older and have a cycloplegic spherical equivalent refraction between -1.00 and -4.50 diopters. The cylindrical correction should be no more than 1 diopter. Intacs consist of two PMMA segments that are inserted into the mid peripheral stroma, outside the central optical zone, the area most critical for clear vision. The result is flexible correction, designed to be permanent and adjustable. It can be reversed, if desired, upon removal of the product. The procedure for Intacs is performed in no more than 30 minutes per eye, in an outpatient setting and under topical anesthesia. Distribution in Belgium and The Netherlands only 10 www.ophtec.com OPHTEC | Cataract Surgery 11 OPHTEC | Cataract Surgery NEW Luna ™ PC 620 Aspherical Hydrophobic Acrylic IOL Ophtec advises to use this IOL in combination with OD 660 DualTec kit 1P Acrylic 2.4 Specifications Lens type: One piece IOL | In the bag fixation Biconvex | Aspherical surface Square edge 360˚ Overall diameter: 10.40 to 10.90 mm* Body diameter: 5.7 / 6.0 mm* Lens material: Hydrophobic Acrylic Haptics: 4 closed loops Angulation 10˚ Refractive index: 1.48 AC depth: 5.55 mm A-constant: 119.0 (ultrasound) 119.4 (laser interference) Available powers: +10.0 D to +30.0 D (1.0 D increments) +14.5 D to +25.5 D (0.5 D increments) (including disposable DualTec SoftTip Injector + 2.4 cartridge): Perfect implantation through 2.5 mm The Luna™ Aspherical Hydrophobic Acrylic IOL and the DualTec™ SoftTip IOL Injector are designed to make implantation through a 2.5 mm incision as easy as possible. It is as simple as this: However the lens is implanted, it will always be correct. Advise: Set DualTec™ to ‘TURN’ for Luna™ • ProGel® ProGel® combines high viscosity and high elasticity with high molecular weight. It provides protection of endothelial cells and allows tissue manoeuvres whenever this is needed in cataract surgery. * Depends on diopter 12 www.ophtec.com OPHTEC | Cataract Surgery NEW QuadrimaX ™ PC 545 Aspherical Hydrophilic Acrylic IOL Ophtec advises to use this IOL in combination with OD 660 DualTec kit 1P Acrylic 2.4 Specifications Lens type: One piece IOL | In the bag fixation Biconvex | Aspherical surface Square edge 360˚ Overall diameter: 10.50 to 11.0 mm* Body diameter: 5.7 / 6.0 mm* Lens material: Hydrophilic Acrylic Haptics: 4 closed loops Angulation 8˚ Refractive index: 1.46 AC depth: 4.96 mm A-constant: 118.0 (ultrasound) 118.5 (laser interference) Available powers: +10.0 D to +30.0 D (1.0 D increments) +14.5 D to +25.5 D (0.5 D increments) (including disposable DualTec SoftTip Injector + 2.4 cartridge): Perfect implantation through 2.5 mm The QuadrimaX™ Aspherical Hydrophilic Acrylic IOL and the DualTec™ SoftTip IOL Injector are designed to make implantation through a 2.5 mm incision as easy as possible. It is as simple as this: However the lens is implanted, it will always be correct. • ArtiVisc®, ArtiViscPlus® & ProGel® ArtiVisc® & ArtiViscPlus® and ProGel® combine high viscosity and high elasticity with high molecular weight. They provide protection of endothelial cells and allow tissue manoeuvres whenever this is needed in cataract surgery. * Depends on diopter 13 www.ophtec.com OPHTEC | Cataract Surgery IOLs hydrophilic acrylic iols The combination of the best materials and a choice of designs, makes the hydrophilic acrylic range complete. These one- and three piece lenses can be implanted through the smallest incisions. The IOLs are manufactured using the latest technology, ensuring flexibility and high accuracy. One Piece IOLs | In the bag Fixation Model 511 Body: 6.0 mm | biconvex square edge Haptics: Overall Ø: QuadrimaX™ | Aspherical | Model 545 Mod. C-loop | 5˚angulation Body: 5.7 - 6.0 mm | biconvex aspherical surface square edge 360˚ 12.5 mm Haptics: 4 closed loops | 8˚angulation A-Constant: 117.8 Overall Ø: 10.5 - 11.0 mm AC Depth: 4.8 mm A-Constant: 118.0 (ultrasound) 118.5 (laser interference AC Depth: 4.96 mm Dioptric Powers: -7.0 D to 35.0 D (1.0 increments) ErgomaX™ 10.5 D to 29.5 D (0.5 increments) Dioptric Powers: 10.0 D to 30.0 D (0.5 increments) 14.5 D to 25.5 D (0.5 increments) | Model 525 MonomaX™ | Model 550 Body: 6.0 mm | biconvex Body: 6.5 mm | biconvex Aspherical sharp edge Haptics: Mod. C-loop | 5˚angulation Haptics: 0˚angulation Edge design: Aspherical sharp edge Overall Ø: 10.5 mm Overall Ø: 12.5 mm A-Constant: 118.0 A-Constant: 118.0 AC Depth: 5.0 mm AC Depth: 5.0 mm Dioptric Powers: -7.0 D to 35.0 D (1.0 increments) Dioptric Powers: -5.0 D to 35.0 D (1.0 increments) 10.5 D to 29.5 D (0.5 increments) 10.5 D to 29.5 D (0.5 increments) Three Piece IOLs | In the bag and Sulcus Fixation TrimaX™ | Model 530 Body: 6.0 mm | biconvex | square edge 26% Hydrophilic Acrylic Haptics: Mod. C-loop | 5˚angulation Blue PES Overall Ø: 13.0 mm A-Constant: 117.8 AC Depth: 4.8 mm Dioptric Powers: -5 D to 35.0 D (1.0 increments) 10.5 D to 29.5 D (0.5 increments) 14 www.ophtec.com OPHTEC | Cataract Surgery IOLs polysiloxane iols Reliable Flexibility This third generation of high quality, long term experience IOLs is made from an optically clear silicone elastomer with a covalently bound UV absorber. This material offers a light transmission of 90% in the visible spectrum Three Piece IOLs | In the bag Fixation Model 410 | Classic Series™ Model 440 | Orange Series™ Optic: 5.8 mm | Clear optic Optic: 5.8 mm | Biconvex | Square edge Biconvex | Square edge Optic Material: Clear Polysiloxane elastomer Loops: Mod. C-loop | 5˚angulation with covalently bound Orange UV Blue PMMA absorber Overall Ø: 12.5 mm Loops: C-fit loop | 10˚angulation A-Constant: 117.5 Brown PMMA AC Depth: 4.7 mm Overall Ø: 12.5 mm A-Constant: 118.0 AC Depth: 5.0 mm Dioptric Powers: -5.0 D to 30.0 D (0.5 increments) Dioptric Powers: -5.0 D to 30.0 D (0.5 increments) Model 415 | Classic Series™ Optic: 5.8 mm | Clear optic Biconvex | Square edge Loops: Mod. C-loop | 5˚angulation Blue PMMA Overall Ø: 13.5 mm A-Constant: 117.5 AC Depth: 4.7 mm Dioptric Powers: -5.0 D to 30.0 D (0.5 increments) Model 430 | Elite Series™ Optic: 5.8 mm | Clear optic Biconvex | Square edge Loops: C-fit loop | 10˚angulation Brown PMMA Overall Ø: 12.5 mm A-Constant: 118.0 AC Depth: 5.0 mm Dioptric Powers: -5.0 D to 30.0 D (0.5 increments) 1515 www.ophtec.com OPHTEC | Cataract Surgery IOLs pmma iols A Surgeon’s Eye for Quality A unique combination of craftsmanship, quality control, care and dedication results in products of incomparable quality. In the Bag Fixation | Model 283 In the Bag Fixation | Model 288 Optic: 5.0 mm | biconvex Optic: 6.0 mm | biconvex Loops: C-fit loop | 10˚angulation Loops: Short C-loop | 10˚angulation Overall Ø: 12.0 mm Overall Ø: 12.75 mm A-Constant: 118.5 A-Constant: 118.2 AC Depth: 4.9 mm AC Depth: 4.8 mm Dioptric Powers: -5.0 D to 30.0 D (1.0 increments) Dioptric Powers: -5.0 D to 34.0 D (1.0 increments) In the Bag Fixation | 10.5 D to 29.5 D (0.5 increments) Model 264 Sclera Fixation 10.5 D to 29.5 D (0.5 increments) | Model 279 5.5 mm | biconvex Optic: 7.0 mm | biconvex Loops: Short C-loop | 10˚angulation Loops: C-loop | 10˚angulation Overall Ø: 12.0 mm 2 Scleral Fixation holes A-Constant: 118.0 Overall Ø: 13.75 mm AC Depth: 4.7 mm A-Constant: 118.5 Dioptric Powers: -5.0 D to 30.0 D (1.0 increments) AC Depth: 4.9 mm Dioptric Powers: 10.0 D to 30.0 D (1.0 increments) Optic: 10.5 D to 29.5 D (0.5 increments) 14.5 D to 29.5 D (0.5 increments) | Model 260 Sulcus Fixation | Model 292 Angle Supported Optic: 6.5 mm | biconvex Optic: 6.0 mm | Convex-plano Loops: Mod. C-loop | 10˚angulation Loops: Step-vaulted Overall Ø: 13.75 mm Overall Ø: 12.75 mm A-Constant: 118.5 A-Constant: 114.2 AC Depth: 4.9 mm AC Depth: 2.8 mm Dioptric Powers: 0.0 D to 30.0 D (1.0 increments) Dioptric Powers: 10.0 D to 26.0 D (1.0 increments) 10.5 D to 29.5 D (0.5 increments) 14.5 D to 23.5 D (0.5 increments) >> 16 www.ophtec.com OPHTEC | Cataract Surgery IOLs artisan® aphakia #1 Backup Lens in complicated Cataract Cases Based on the long term experience of Iris Fixation, the ARTISAN® Aphakia IOL is a predictable, safe, high precision implant, that corrects the eye when it is not correctable by other means. Pediatric lenses are available upon request for juvenile or congenital cataract cases. Iris Fixation | Model 205 ARTISAN® Aphakia Optic: 5.4 mm Haptics: Iris Claw® Overall Ø: 8.5 mm A-Constant: 115.0 (ultrasound) 115.7 (laser interference) AC Depth: OD 125 ARTISAN® / ARTIFLEX® Disposable Enclavation Needle 3.3 mm Dioptric Powers: 2.0 D to 30.0 D (1.0 increments) 14.5 D to 24.5 D (0.5 increments) D02 74 ARTISAN® Implantation Forceps Standard Also available: ARTISAN® Pediatric Aphakia 4.4/6.5 and 4.4/7.5 Designed for small eyes ARTISAN® Training Course To obtain the best results, OPHTEC continuously conducts specialized training courses throughout the world to develop and maintain surgical skills. OPHTEC’s condition to use the product correctly is to provide ARTISAN® IOLs only to certified professionals. For more information on training courses send an e-mail to [email protected], or call +31 50 525 1944. 17 www.ophtec.com OPHTEC | Cataract Surgery Injectors dualtec™ softtip iol injector The DualTec™ SoftTip IOL Injector is a single use lens injector for one piece hydrophilic acrylic IOLs with 2.5 mm incision. The special feature to switch over from push to turn function and reverse gives perfect ergonomy for a precise implantation. OD 660 DualTec Kit 1P Acrylic 2.4 DualTec SoftTip Injector + 2.4 cartridge for 1 piece acrylic IOLs P 2.5 mm incision One piece hydrophilic acrylic IOLs can be implanted through a 2.5mm incision using the OD660 P switch for freedom of choice: push or turn DualTec™ Kit consisting of a single use DualTec™ SoftTip IOL Injector and Locking Wing System™ Micro Tip Cartridges. perfect ergonomy for precise implantation A hard tip version is available for three piece IOLs; P single use OD 640 DualTec™ kit 3P Polysiloxane 3.0 safe, hygienic, constant quality OD 650 DualTec™ kit 3P Acrylic 3.0 P microtip cartridge convenient cartridge loading Reusable Systems Single Use Systems Injector + Cartridge (box of 10) • OD 640 DualTec kit 3P Polysiloxane 3.0 • OD 650 DualTec kit 3P Acrylic 3.0 OD230 Foldable Lens Injector | Push Technique OD233 Foldable Lens Injector | Rotating • OD 660 DualTec kit 1P Acrylic 2.4 Cartridge (box of 10) Technique • OD 401 LWS Cartridge 3P Polysiloxane 3.0 • OD 501 LWS Cartridge 3P Acrylic 3.0 • OD 521 LWS Cartridge 1P Acrylic 2.4 18 www.ophtec.com OPHTEC | Cataract Surgery capsular tension rings Flexible Insertion, Stable Result Highly flexible due to the compression molding technology. These PMMA Capsular Tension Rings are indicated for the stabilization of weakened, broken or missing zonules preventing IOL decentration after capsular shrinking. Capsular Tension Ring | Model 275 Capsular Tension Ring | 12/10 Model 276 13/11 Compression: From 12 mm to 10 mm Compression: From 13 mm to 11 mm Material: PMMA | Flexible Ring Material: PMMA | Flexible Ring Available in: Clear and brown PMMA Available in: Clear and brown PMMA Overall Ø: 12 mm Overall Ø: 13 mm Recommended to be used in combination with the ON 385 EASY Control™ Micro Inserter 19 www.ophtec.com OPHTEC | Cataract Surgery IOLs viscoelastics ArtiVisc®, ArtiViscPlus® & ProGel® ArtiVisc® & ArtiViscPlus® (sodium hyaloronic acid), combine high viscosity and high elasticity with high molecular weight. ArtiVisc(Plus)® • Sodium hyaluronate 1% (ArtiViscPlus®: 1.4 %) • High molecular weight polymers (ArtiVisc®: >4 million daltons, ArtiViscPlus®: >5 million daltons) • Viscosity (zero shear rate, 25˚C) Average 1 million cPs (ArtiViscPlus®: 3.3 million cPs) • 27 gauge cannula • pH 7.0 - 7.5 • Iso-osmolar 320 mOsm/kg • Single Use Also Available: ProGel® • HPMC | Hydroxy Propyl Methyl Cellulose • Molecular weight 92 kilodalton • Viscosity 4.5 k cPs • Single Use OV200 ProGel® H53.16.010 ArtiVisc® 1 % H53.16.015 ArtiVisc®1 % H53.16.020 ArtiViscPlus® 1.4 % H53.16.025 ArtiViscPlus® 1.4 % 0.85 ml 0.55 ml 0.85 ml 0.55 ml H53.16.035 ArtiVisc® CombiPack 0.55 ml 20 2.0 ml www.ophtec.com OPHTEC | Cataract Surgery Instruments surgical knives Clear Corneal Knives Clear Corneal Knives have been designed specifically for clear corneal incisions. Angled Type OM200 2.65 mm Angled, full Handle OM201 2.75 mm Angled, full Handle OM202 2.85 mm Angled, full Handle OM203 3.0 mm Angled, full Handle OM204 3.2 mm Angled, full Handle Implant Knives Implant Knives are designed to create a precise incision for lens insertion. Straight Type OM 248 4.0 mm Straight, full Handle OM 249 5.2 mm Straight, full Handle Angled Type OM 250 4.0 mm Angled, full Handle OM 251 5.2 mm Angled, full Handle Precision Implant Knives Precision Slit Knives penetrate easily while making an accurate width incision for optimal fit to the phacoemulsification tip. OM 255 OM 256 OM 257 OM 258 Straight Type 2.65 mm Straight, full Handle 2.85 mm Straight, full Handle 3.00 mm Straight, full Handle 3.20 mm Straight, full Handle OM 241 OM 242 OM 243 OM 244 OM 245 OM 246 OM 247 Angled Type 3.2 mm Angled, full Handle, bevel up 3.5 mm Angled, full Handle, bevel up 3.75 mm Angled, full Handle, bevel up 5.2 mm Angled, full Handle, bevel up 5.5 mm Angled, full Handle, bevel up 5.7 mm Angled, full Handle, bevel up 6.0 mm Angled, full Handle, bevel up Spoon Knives Slit Knives Slit Knives allow straight, smooth penetration without tissue drag. OM 259 OM 260 OM 261 OM 262 OM 263 OM 264 OM 265 OM 266 Type Spoon Knife, angled, double bevel, 320° cutting edge Spoon Knife, angled, double bevel, 320° cutting edge Straight 3.5 mm Angled Type OM 269 2.5 mm Straight, full Handle, double Bevel OM 270 2.65 mm Straight, full Handle, double Bevel OM 271 2.8 mm Straight, full Handle, double Bevel OM 272 3.0 mm Straight, full Handle, double Bevel OM 273 3.2 mm Straight, full Handle, double Bevel OM 274 3.5 mm Straight, full Handle, double Bevel Straight 2.65 mm 3.0 mm 3.2 mm Angled OM 278 3.0 mm OM 279 3.2 mm Type 70 ° Angled, full Handle, Bevel up Stab Knives are heat-tempered to provide a strong, true point for easy penetration during initial stab incisions. OM 225 OM 226 OM 227 OM 228 Straight 15° 22,5° 30° 45° Type Straight , Full Handle Straight , Full Handle Straight , Full Handle Straight , Full Handle Crescent Design Knives - Straight Type Straight, full Handle Straight, full Handle Straight, full Handle Crescent Knives provide consistent sharpness, which nearly eliminates tissue drag. Ideal knives for creating a smooth scleral shelf to promote a self-sealing wound. Type Straight, full Handle, double Bevel Straight, full Handle, double Bevel Type OM 290 Straight, full handl Needle Blade Angled OM 278 3.0 mm The unique 320° cutting surface and ultra-thin blade enhance precision cutting capabilities where OM 279 3.2 mm multi-directional techniques are used. Angled OM 310 3.2 mm OM 311 3.0 mm Slit Knives with parallel sides are designed to hold tissue at the desired width while entering and exiting the wound. Angled Type 2.5 mm Straight, full Handle, Bevel up 2.65 mm Straight, full Handle, Bevel up 2.75 mm Straight, full Handle, Bevel up 2.85 mm Straight, full Handle, Bevel up Special Angled 3.0 mm Straight, full Handle, Bevel up OM 267 3.2 mm 3.2 mm Straight, full Handle, Bevel up 3.5 mm Straight, full Handle, Bevel up 5.1 mm Straight, full Handle, Bevel up Stab Knives Type OM 268 Straight, full Handle, double Bevel OM 275 OM 276 OM 277 Slit Knives - Parallel Sides Special Angled Type Straight, full Handle, double Bevel Straight, full Handle, double Bevel Paracentesis Knife Straight Type OM 302 1.0 mm Paracentesis Knife, straight 21 OM 291 OM 292 OM 293 Type Angled, full handle, Bevel up Angled, full handle, Bevel down Angled, full handle, double Bevel Vitrectomy Knives Vitrectomy Knives create small, precise access incisions which help prevent leakage around probes and other posterior segment instruments. OM 320 OM 321 OM 322 Type Vitrectomy Knife Vitrectomy Knife Vitrectomy Knife, angle Gauge 19 Gauge 20 Gauge 20 Gauge www.ophtec.com OPHTEC | Cataract Surgery Instruments / Equipment Clear Corneal Trephines Ophtec’s Corneal Trephine has special cutting characteristics. Due to the extreme sharpness, the incision causes less deformation and distortion than usual and gives no wedge formation. Code OT 16600 OT 16625 OT 16650 OT 16675 OT 16700 OT 16725 OT 16750 OT 16775 OT 16800 OT 16825 OT 16850 assistant Code OT 16875 OT 16900 OT 16925 OT 16950 OT 16975 OT 161000 OT 161050 OT 161100 OT 161150 OT 161200 Diameter 6.00 mm Ø 6.25 mm Ø 6.50 mm Ø 6.75 mm Ø 7.00 mm Ø 7.25 mm Ø 7.50 mm Ø 7.75 mm Ø 8.00 mm Ø 8.25 mm Ø 8.50 mm Ø Diameter 8.75 mm Ø 9.00 mm Ø 9.25 mm Ø 9.50 mm Ø 9.75 mm Ø 10.00 mm Ø 10.50 mm Ø 11.00 mm Ø 11.50 mm Ø 12.00 mm Ø pulsar2 Minimal Stress ESP Complete Workstation for Anterior & Posterior Segment Surgery Modular System for the Anterior & Posterior Segment Surgery OPTIKON Assistant Minimal Stress OPTIKON Pulsar2 ESP Special Features: • EASYSYS, Ergonomic Design I/A Cassette • U/S Programmable Emission Mode • Co-M.I.C.S. & M.I.C.S. Product line (Incision size range 3.2 mm - 1.0 mm) • Hyperspeed Vitrectomy: up to 4000 cuts/min • EMERGENCY MAX PRESSURE Command • DOUBLE H.I.D Xenon Light Source • 23G & 25G Product line • Ready for ECLIPSE Video Overlay Console • Continuous Micrometrical Stroke Length Control & Adjustment by Minimal Stress System • Double Infusion: Forced Minimal IOP & Built-in Programmable IV Pole • Double Pump: Venturi & Peristaltic • Programmable, Simultaneous Double Linear Control Footpedal • LCD Touch Screen Special Features: • EasySys Double Pump I/A Cassette • Double Infusion System • P.E.M. Programmable Emission Mode • U/S Continuous, Pulsed, Burst • Accessories for Co-M.I.C.S. & M.I.C.S. • Vit Module (optional) Distribution in the Netherlands only. Distribution in the Netherlands only. statim 5000 steam sterilizer Statim 5000 Cassette Autoclave Designed specifically for speed, Statim 5000 takes approximately 9 minutes for a complete sterilization cycle. Benefits: •Fast: Statim allows today’s surgeon convenient sterilization between each patient •Safe: eliminating all biological hazards while incorporating built-in safety standard •Gentle: protecting your investment in delicate and expensive instruments. Distribution in the Netherlands only. 22 www.ophtec.com OPHTEC | Trauma Surgery 23 www.ophtec.com OPHTEC | Trauma Surgery IOLs aniridia lenses Unique and Reliable A unique solution for the correction of aniridia as well as iris coloboma. Coloured body and haptics and additional optical correction are available for scleral, sulcus and capsular bag fixation. HMK ANI 2 | Models 311 Optic: HMK ANI 2 4.0 mm | Models 311 without optic Pupil Aperture: 4.0 mm other optic diameter on request other pupil aperture size on request Body: 9.0 mm Body: 9.0 mm Loops: C-loop Loops: C-loop Overall Ø: 13.75 mm Overall Ø: 13.75 mm A-Constant: 118.5 Colours: Brown, green, blue, black* AC Depth: 4.9 mm Dioptric Powers: 0.0 D and 1.0 D to 30.0 D (0.5 increments) Colours: Brown, green, blue, black* ips® elements Unlimited Solutions The patented Iris Prosthetic System (IPS®) concept consists of different combinable elements which are available in various colours. The IPS® elements restore the iris diaphragm and can be used in conjunction with a posterior chamber IOL and a Capsular Tension Ring. An additional IPS® Fixation Ring counteracts secondary shrinking of the capsular bag and stabilizes the artificial aperture. IPS® Double Element | Models 321, 322, 323 IPS® Single Element | Models 324, 325 Model 321: Overal Ø: 10.5 mm Pupil Aperture: 4.0 mm Model 324: Overal Ø: 10.5 mm Model 322: Overal Ø: 10.5 mm Pupil Aperture: 4.0 mm Pupil Aperture: 3.0 mm Model 325: Overal Ø: 10.5 mm Model 323: Overal Ø: 11.0 mm Pupil Aperture: 3.0 mm Pupil Aperture: 4.0 mm Colours: Brown, green, blue, black* Colours: Brown, green, blue, black* IPS® Fix Ring | Model 326 Overall Ø: 7.0 mm Body Ø: 6.0 mm Pupil Aperture: 3.0 mm Colours: Brown, green, blue, black* Only to be used on devices with a pupil aperture of 4 mm *Black Implants or elements are available as patient design devices. 24 www.ophtec.com OPHTEC | Trauma Surgery IOLs patient design Unique problem, unique solution Designing and manufacturing special iris reconstruction implants for cases in which standard Iris Reconstruction Implants do not apply. Patient Design IOLs are developed in close cooperation with the surgeon to provide a unique problem solving solution. ARTISAN® Pupil Occluder | Patient Design Optic Ø: 5.4 mm Overall Ø: 8.5 mm Loops: Flexible Iris Claws® Colours: Black available colours Ophtec’s Iris Reconstruction Implants are available in brown, green and blue. These colours have been carefully chosen to simulate the natural colouring of most eyes. Also available in black as patient design devices. Colour specifications of the Iris Reconstruction Implants Warning: 1. The Anterior Segment Reconstruction Prostheses are only available in 3 standard colours and therefore OPHTEC cannot guarantee the perfect colour match with the fellow eye; 2. After implantation in the eye the colour of the prosthesis might look lighter; 3. For a better evaluation and choice of the colour match, we suggest you to consult OPHTEC representatives; 4. Black Polycarbonate is more fragile than other (PMMA) colours. 25 www.ophtec.com OPHTEC BV P.O. Box 398 9700 AJ Groningen The Netherlands Schweitzerlaan 15 9728 NR Groningen The Netherlands T: +31 50 525 1944 F: +31 50 525 4386 E: [email protected] Sales Department, The Netherlands: T: +31 50 527 5400 F: +31 50 527 4996 OPHTEC USA, Inc. OPHTEC España OPHTEC South Africa Suite 112 c/ Velázquez, 94 1º Building 1 Unit 4, Visiomed Office Park 6421 Congress Ave. (Zuricenter) 269 Beyers Naude Drive Boca Raton 28006 • Madrid Blackheath Ext.1 FL 33487 T: 900 993 174 Johannesburg, South Africa T: +1 561 989 8767 F: 900 993 192 T: +27 825540949 F: +1 561 989 9744 E: [email protected] F: +27 866139065 E: [email protected] E: [email protected] www.ophtec.com 26 ©OPHTEC BV 2010 | Information in this document iswww.ophtec.com subject to modification
Similar documents
Artisan Toric Phakic IOLs leaflet.indd
develop and maintain surgical skills. By providing lenses only to certifi ed professionals, OPHTEC guarantees the constant high quality of the results with the product. For more information on trai...
More information