EN54-23 - Hochiki Europe
Transcription
EN54-23 - Hochiki Europe
Choosing your VAD CHQ-WB An Addressable Loop-Powered Beacon, with a high intensity LED and a custom designed free-form optic which produces a highly visible flash. The unit is designed to fit the YBN-R/3, YBNR/3(SCI), YBO-BS or the YBO-R/(SCI), and is available in Red or White LEDs. Loop Powered Single loop address via TCH-B100 High Intensity LED technology 0.5/1 Hz flash frequency Addressable via TCH-B100 Choice of 2 LED colours (red and white) Approved to EN54-23:2010 Category ‘W’ High efficiency Selectable light output** Operating voltage 17-41 vdc Type Wall Beacons Base Models LED Colour What type of VAD? Which case colour? Ivory case White case Product Colour CHQ-WB/WL White Ivory CHQ-WB(WHT)/WL White White CHQ-WB(RED)/WL White Red CHQ-WB/RL Red Ivory CHQ-WB(WHT)/RL Red White CHQ-WB(RED)/RL Red Red Red case Wall Sounder Beacon White case Which LED colour? Product White LEDs YBO-BSB2/WL Red LEDs YBO-BSB2/RL White LEDs YBO-BSB2(WHT)/WL Red LEDs YBO-BSB2(WHT)/RL White LEDs CHQ-WSB2/WL Red LEDs CHQ-WSB2/RL White LEDs CHQ-WSB2(WHT)/WL Red LEDs CHQ-WSB2(WHT)/RL EN54-23 Ratings 1 2 3 CHQ-CB/RL O C-3-7.5 C-3-10 CHQ-CB/WL C-3-5 C-3-7.5 C-3-10 CHQ-CB/WL-15 O C-3-10 C-3-15 CHQ-CB(WHT)/RL O C-3-7.5 C-3-10 CHQ-CB(WHT)/WL C-3-5 C-3-7.5 C-3-10 CHQ-CB(WHT)/WL-15 O C-3-10 C-3-15 CHQ-CB(RED)/RL O C-3-7.5 C-3-10 CHQ-CB(RED)/WL C-3-5 C-3-7.5 C-3-10 CHQ-CB(RED)/WL-15 O C-3-10 C-3-15 White LEDs CHQ-WB/WL W-2.4-5 W-2.4-6 W-2.4-7 Red LEDs CHQ-WB/RL O O W-2.4-5 White LEDs CHQ-WB(WHT)/WL W-2.4-5 W-2.4-6 W-2.4-7 Red LEDs CHQ-WB(WHT)/RL O O W-2.4-5 White LEDs CHQ-WB(RED)/WL W-2.4-5 W-2.4-6 W-2.4-7 Red LEDs CHQ-WB(RED)/RL O O W-2.4-5 Red LEDs An Addressable Loop-Powered Base Sounder Beacon, providing 13 volume levels and 51 tones with a maximum output of up to 98 dB(A) (±2 dB(A)) with low current consumption. The unit is designed to fit either the YBN-R/3, YBO-R/SCI Bases. Base Sounder Beacons Loop Powered Single Loop Address, addressed by either Control Panel or TCH-B100 50 ~ 98 dB(A) (±2 dB(A)) output at 1m Fits Hochiki Standard or Isolator Bases and supports ESP Sensors and Remote Indicator 51 User-Selectable Tones (all tones EN54-3 compatible) Beacon and Sounder can be controlled independently** Approved to EN54-23: 2010 Category ‘O’ Operating voltage 17-41 vdc YBO-BSB2/WL White Ivory YBO-BSB2(WHT)/WL White White YBO-BSB/RL Red Ivory YBO-BSB2(WHT)/RL Red White Ivory case White case Red case Ivory case Wall Beacon White case Wall Sounder Beacons Red case White LEDs CDXconventional As per CHQ-WS2 plus: An Addressable Loop-Powered Wall Sounder Beacon, as per the CHQ-WS2 but additionally featuring an integral beacon within the horn which utilises high intensity LED technology. Special bases available: YBO-R/3(RED), YBO-R/ SCI(RED), YBO-R/3(WHT) and YBO-R/ SCI(WHT-SNDR). White LEDs Red LEDs **Panel compatibility dependent CHQ-WSB2 White LEDs Red LEDs Ceiling Beacon A Guide to Our Products ‘O’ Rated **Panel compatibility dependent YBO-BSB2 Variable flash frequency High Intensity LED technology Independent control of Sounder and Beacon Auto-shutdown Mode available - can be set independently for sounder or beacon** Approved to EN54-23: 2010 Category ‘O’ Operating voltage 17-41 vdc CHQ-WSB2/WL White Red CHQ-WSB2(WHT)/WL White White What type of VAD? Which case colour? Red case Standard Base White case Red case Waterproof Base White case CHQ-WSB2/RL Red Red CHQ-WSB2(WHT)/RL Red White **Panel compatibility dependent www.hochikieurope.com/loudandclear > VADs ESPintelligent Base Sounder Beacon Product Model Information Compliant With the wide choice of VAD variants available it might seem a daunting task to identify the best unit for the application. Therefore we have devised this simple configuration table which allows you to source the correct VAD by answering questions and following the branches to the appropriate device variant. Simply select the VAD type, then the case colour and finally the LED colour. The ratings column allows you to check the coverage volume settings available. Coverage volumes are selected via the CIE*. HOCHIKI EUROPE (UK) LIMITED EN54-23 Ratings Which LED colour? Product White LEDs CWST-RW-S5 W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5 Red LEDs CWST-RR-S5 W-2.4-6.2 C-3-9.4 C-6-8.6 - White LEDs CWST-WW-S5 W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5 Red LEDs CWST-WR-S5 W-2.4-6.2 C-3-9.4 C-6-8.6 - White LEDs CWST-RW-W5 W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5 Red LEDs CWST-RR-W5 W-2.4-6.2 C-3-9.4 C-6-8.6 - White LEDs CWST-WW-W5 W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5 Red LEDs CWST-WR-W5 W-2.4-6.2 C-3-9.4 C-6-8.6 - Wall Fitted Ceiling Ceiling Grosvenor Road, Gillingham Business Park, Gillingham, Kent, ME8 0SA, United Kingdom T: +44 (0)1634 260133 F: +44 (0)1634 260132 E: (UK Sales) [email protected] E: (Non UK Sales) [email protected] W: www.hochikieurope.com/loudandclear * Check CIE compatibility ESPintelligent EN54-23 Your Safety, Our Technology Our Products Our Products EN54-23 - An Introduction Our Products Visual Alarm Devices (VADs) are an essential component to most fire alarm systems. They provide a visual indication of an alarm condition to those people who wouldn’t normally be alerted to a fire by standard audible-only devices such as sounders and bells. The Disability Discrimination Act of 1995 has highlighted the need for the inclusion of VADs in all public buildings, specifically in areas where people with impaired hearing work in isolation. However VADs are also required in noisy environments where staff might be wearing ear defenders such as factories, foundries etc. A new product standard, BS EN 54-23:2010 (Fire detection and fire alarms systems. Part 23: Fire alarm devices - Visual alarm devices), has been introduced primarily to standardise the requirements, test methods and performance of VADs and ensure their light output is measured in a uniform manner. This standard will be mandatory throughout Europe from 31st December 2013 and all manufacturers of VADs will be affected. CDXconventional Key Features of the Hochiki Range of EN54-23 Compliant VADs CWST-S5 A Conventional Beacon which features high Hochiki’s range of VADS which will be fully EN54-23 compliant will be available Q2 2014. The EN54-23 ratings of these Beacons (the brightness of the LEDs – which affects the area that is illuminated) can be adjusted on each model from the control panel*. This reduces the number of devices required in the range as each one can produce up to three different ratings making it easier to choose the right VAD for the task. Calculating Coverage Volume The circuitry in our new Wall and Ceiling Beacons is continually monitored to ensure that it is still functioning. A malfunctioning device will show at the panel as a fault saving time and effort on maintenance inspections*. The needs for VADs will be identified as part of the risk assessment. As with other fire alarm system components, there are a number of challenges that must be considered in the layout design and installation of VADs. When in operation, these Beacons monitor the LED light output via a separate sensor to ensure that a flash occurs, again saving time on scheduled walk-tests. A failure to operate is indicated as a fault at the panel**. One challenge is the illumination of the entire volume of the open space where the alarm must be visible. VADs must produce sufficiently intense light, so that an individual located anywhere in the space, looking either towards or away from the VAD, would be alerted in the event of an emergency. The control panel can be programmed to perform an automatic daily LED check on our Wall and Ceiling Beacons, consisting of a lower power single flash, recorded by the in-built sensor. This reduces the probability of a failure on demand, just when the device is needed. A failure is indicated at the panel**. The performance of VADs under the new standard is now assessed against a minimum required illumination of 0.4 lux on surfaces perpendicular to the direction of the light emitted from the device. Our new Wall and Ceiling Beacons have the ability to be powered externally from a separate 24V power supply. This means for projects that require many VADs the loop current isn’t drained by the LEDs when they are activated (meaning more devices on the loop is possible)**. VADs will now be classified into three categories based on their application: Custom-designed lens W - Wall-mounted C - Ceiling-mounted O - Open Category LED technology Approved to EN54-23, C & W categories Advanced optics ensures superior light coverage at low current draw Synchronised flash exceeds EN54-23 standard Soft start feature reduces power surges during system start-up Available in either red or white casings Available with either a red or white LED Product Model Information Type Wall & Ceiling Beacons Base Models LED Colour Product Colour CWST-RW-S5 White Red CWST-RR-S5 Red Red CWST-WW-S5 White White CWST-WR-S5 Red White Outdoor variants available (used with the wall sounder weatherproofing kit) W and C mounting categories are specified at specific installation heights and particular patterns of coverage - see below for more information. Within these two categories, the shape of the volume covered is fixed by the standard. The dimensions of this coverage volume are specified by the manufacturer. For all categories, the volume covered can be used to determine VAD spacing within the building. W Category (Wall-mounted) Coverage Volume C Category (Ceiling-Mounted) Coverage Volume Wall mounted VADs cover a cuboid volume with a square floor area. The coverage volume is presented as a code in the form of W - X - Y, where W = Wall-mounted category. X is the maximum mounting height (m) and Y is the width and length (m) of the coverage floor area - see diagram. The minimum mounting height allowable by the standard is 2.4m. Ceiling-mounted VADs cover a cylindrical area. The coverage volume is presented as a code in the form C - X - Y, where C = Ceiling-mounted category. X is the maximum mounting height (m) and Y is the diameter (m) of the coverage volume’s floor area - see diagram. The maximum mounting height can only be specified as 3, 6 or 9m. For example Hochiki’s wall-mounting VAD has a classification of W-2.4-5. This means it should be mounted at 2.4m from the floor and will cover an area of up to 5m by 5m output LEDs, advanced optics and an innovative lens design, providing outstanding Omnidirectional light coverage at low current draw. Specifically designed for, and approved to meet EN54-23. CWST-S5 delivers quality, reliability and long operational life. The new Wall and Ceiling Beacons in our new EN54-23 compliant range are available with either red or white LEDs offering additional flexibility to the end-installer when deciding on the requirements of each installation VAD Y X Y ESPintelligent CHQ-CB An Addressable Loop-Powered Beacon, with a high intensity LED and a custom designed free-form optic which produces a highly visible flash. Coverage diameters include 5m, 7.5m, 10m and 15m diameter*. The unit is designed to fit the YBN-R/3, YBN-R/3(SCI), YBO-BS or the YBO-R/(SCI), and is available in Red or White LEDs. Loop Powered Single loop address via TCH-B100 High Intensity LED technology 0.5/1 Hz flash frequency Addressable via TCH-B100 Choice of 2 LED colours (red and white) Approved to EN54-23:2010 Category ‘C’ High efficiency Selectable light output** Operating voltage 17-41 vdc CWST-W5 A Conventional Weatherproof Beacon, which features high output LEDs, advanced optics and an innovative lens design, providing outstanding Omni-directional light coverage at low current draw. Specifically designed for, and approved to meet EN54-23. The CWST-W5 delivers outstanding quality, reliability and long operational life. Weatherproof base provides IP65 for external use applications Product Model Information For example Hochiki’s ceilingmounting VAD has a classification of C-3-15. This means it can be mounted up to 3m from the floor and will cover a cylindrical area of 15m diameter. Type VAD X Ceiling Beacons Base Models LED Colour CHQ-CB/WL White Ivory CHQ-CB(WHT)/WL White White CHQ-CB(RED)/WL White Red CHQ-CB/WL-15 White Product Colour Base Models LED Colour CWST-RW-W5 White Red CWST-RR-W5 Red Red Ivory CWST-WW-W5 White White CWST-WR-W5 Red White CHQ-CB(WHT)/WL-15 White White CHQ-CB(RED)/WL-15 White Red CHQ-CB/RL Red Ivory CHQ-CB(WHT)/RL Red White CHQ-CB(RED)/RL Red Red *0.5Hz flash frequency white LED **Panel compatibility dependent www.hochikieurope.com/loudandclear > www.hochikieurope.com/loudandclear > Approved to En54-23, C & W categories Advanced optics ensures superior light coverage at low current draw Synchronised flash exceeds EN54-23 standard Soft start feature reduces power surges during system start up IP65 Available in either red or white casings Available with either a red or white LED Product Model Information Type Y The width of the room is Y/1.414 www.hochikieurope.com/loudandclear > Product Colour Our Products EN54-23 - An Introduction Our Products Visual Alarm Devices (VADs) are an essential component to most fire alarm systems. They provide a visual indication of an alarm condition to those people who wouldn’t normally be alerted to a fire by standard audible-only devices such as sounders and bells. The Disability Discrimination Act of 1995 has highlighted the need for the inclusion of VADs in all public buildings, specifically in areas where people with impaired hearing work in isolation. However VADs are also required in noisy environments where staff might be wearing ear defenders such as factories, foundries etc. A new product standard, BS EN 54-23:2010 (Fire detection and fire alarms systems. Part 23: Fire alarm devices - Visual alarm devices), has been introduced primarily to standardise the requirements, test methods and performance of VADs and ensure their light output is measured in a uniform manner. This standard will be mandatory throughout Europe from 31st December 2013 and all manufacturers of VADs will be affected. CDXconventional Key Features of the Hochiki Range of EN54-23 Compliant VADs CWST-S5 A Conventional Beacon which features high Hochiki’s range of VADS which will be fully EN54-23 compliant will be available Q2 2014. The EN54-23 ratings of these Beacons (the brightness of the LEDs – which affects the area that is illuminated) can be adjusted on each model from the control panel*. This reduces the number of devices required in the range as each one can produce up to three different ratings making it easier to choose the right VAD for the task. Calculating Coverage Volume The circuitry in our new Wall and Ceiling Beacons is continually monitored to ensure that it is still functioning. A malfunctioning device will show at the panel as a fault saving time and effort on maintenance inspections*. The needs for VADs will be identified as part of the risk assessment. As with other fire alarm system components, there are a number of challenges that must be considered in the layout design and installation of VADs. When in operation, these Beacons monitor the LED light output via a separate sensor to ensure that a flash occurs, again saving time on scheduled walk-tests. A failure to operate is indicated as a fault at the panel**. One challenge is the illumination of the entire volume of the open space where the alarm must be visible. VADs must produce sufficiently intense light, so that an individual located anywhere in the space, looking either towards or away from the VAD, would be alerted in the event of an emergency. The control panel can be programmed to perform an automatic daily LED check on our Wall and Ceiling Beacons, consisting of a lower power single flash, recorded by the in-built sensor. This reduces the probability of a failure on demand, just when the device is needed. A failure is indicated at the panel**. The performance of VADs under the new standard is now assessed against a minimum required illumination of 0.4 lux on surfaces perpendicular to the direction of the light emitted from the device. Our new Wall and Ceiling Beacons have the ability to be powered externally from a separate 24V power supply. This means for projects that require many VADs the loop current isn’t drained by the LEDs when they are activated (meaning more devices on the loop is possible)**. VADs will now be classified into three categories based on their application: Custom-designed lens W - Wall-mounted C - Ceiling-mounted O - Open Category LED technology Approved to EN54-23, C & W categories Advanced optics ensures superior light coverage at low current draw Synchronised flash exceeds EN54-23 standard Soft start feature reduces power surges during system start-up Available in either red or white casings Available with either a red or white LED Product Model Information Type Wall & Ceiling Beacons Base Models LED Colour Product Colour CWST-RW-S5 White Red CWST-RR-S5 Red Red CWST-WW-S5 White White CWST-WR-S5 Red White Outdoor variants available (used with the wall sounder weatherproofing kit) W and C mounting categories are specified at specific installation heights and particular patterns of coverage - see below for more information. Within these two categories, the shape of the volume covered is fixed by the standard. The dimensions of this coverage volume are specified by the manufacturer. For all categories, the volume covered can be used to determine VAD spacing within the building. W Category (Wall-mounted) Coverage Volume C Category (Ceiling-Mounted) Coverage Volume Wall mounted VADs cover a cuboid volume with a square floor area. The coverage volume is presented as a code in the form of W - X - Y, where W = Wall-mounted category. X is the maximum mounting height (m) and Y is the width and length (m) of the coverage floor area - see diagram. The minimum mounting height allowable by the standard is 2.4m. Ceiling-mounted VADs cover a cylindrical area. The coverage volume is presented as a code in the form C - X - Y, where C = Ceiling-mounted category. X is the maximum mounting height (m) and Y is the diameter (m) of the coverage volume’s floor area - see diagram. The maximum mounting height can only be specified as 3, 6 or 9m. For example Hochiki’s wall-mounting VAD has a classification of W-2.4-5. This means it should be mounted at 2.4m from the floor and will cover an area of up to 5m by 5m output LEDs, advanced optics and an innovative lens design, providing outstanding Omnidirectional light coverage at low current draw. Specifically designed for, and approved to meet EN54-23. CWST-S5 delivers quality, reliability and long operational life. The new Wall and Ceiling Beacons in our new EN54-23 compliant range are available with either red or white LEDs offering additional flexibility to the end-installer when deciding on the requirements of each installation VAD Y X Y ESPintelligent CHQ-CB An Addressable Loop-Powered Beacon, with a high intensity LED and a custom designed free-form optic which produces a highly visible flash. Coverage diameters include 5m, 7.5m, 10m and 15m diameter*. The unit is designed to fit the YBN-R/3, YBN-R/3(SCI), YBO-BS or the YBO-R/(SCI), and is available in Red or White LEDs. Loop Powered Single loop address via TCH-B100 High Intensity LED technology 0.5/1 Hz flash frequency Addressable via TCH-B100 Choice of 2 LED colours (red and white) Approved to EN54-23:2010 Category ‘C’ High efficiency Selectable light output** Operating voltage 17-41 vdc CWST-W5 A Conventional Weatherproof Beacon, which features high output LEDs, advanced optics and an innovative lens design, providing outstanding Omni-directional light coverage at low current draw. Specifically designed for, and approved to meet EN54-23. The CWST-W5 delivers outstanding quality, reliability and long operational life. Weatherproof base provides IP65 for external use applications Product Model Information For example Hochiki’s ceilingmounting VAD has a classification of C-3-15. This means it can be mounted up to 3m from the floor and will cover a cylindrical area of 15m diameter. Type VAD X Ceiling Beacons Base Models LED Colour CHQ-CB/WL White Ivory CHQ-CB(WHT)/WL White White CHQ-CB(RED)/WL White Red CHQ-CB/WL-15 White Product Colour Base Models LED Colour CWST-RW-W5 White Red CWST-RR-W5 Red Red Ivory CWST-WW-W5 White White CWST-WR-W5 Red White CHQ-CB(WHT)/WL-15 White White CHQ-CB(RED)/WL-15 White Red CHQ-CB/RL Red Ivory CHQ-CB(WHT)/RL Red White CHQ-CB(RED)/RL Red Red *0.5Hz flash frequency white LED **Panel compatibility dependent www.hochikieurope.com/loudandclear > www.hochikieurope.com/loudandclear > Approved to En54-23, C & W categories Advanced optics ensures superior light coverage at low current draw Synchronised flash exceeds EN54-23 standard Soft start feature reduces power surges during system start up IP65 Available in either red or white casings Available with either a red or white LED Product Model Information Type Y The width of the room is Y/1.414 www.hochikieurope.com/loudandclear > Product Colour Our Products EN54-23 - An Introduction Our Products Visual Alarm Devices (VADs) are an essential component to most fire alarm systems. They provide a visual indication of an alarm condition to those people who wouldn’t normally be alerted to a fire by standard audible-only devices such as sounders and bells. The Disability Discrimination Act of 1995 has highlighted the need for the inclusion of VADs in all public buildings, specifically in areas where people with impaired hearing work in isolation. However VADs are also required in noisy environments where staff might be wearing ear defenders such as factories, foundries etc. A new product standard, BS EN 54-23:2010 (Fire detection and fire alarms systems. Part 23: Fire alarm devices - Visual alarm devices), has been introduced primarily to standardise the requirements, test methods and performance of VADs and ensure their light output is measured in a uniform manner. This standard will be mandatory throughout Europe from 31st December 2013 and all manufacturers of VADs will be affected. CDXconventional Key Features of the Hochiki Range of EN54-23 Compliant VADs CWST-S5 A Conventional Beacon which features high Hochiki’s range of VADS which will be fully EN54-23 compliant will be available Q2 2014. The EN54-23 ratings of these Beacons (the brightness of the LEDs – which affects the area that is illuminated) can be adjusted on each model from the control panel*. This reduces the number of devices required in the range as each one can produce up to three different ratings making it easier to choose the right VAD for the task. Calculating Coverage Volume The circuitry in our new Wall and Ceiling Beacons is continually monitored to ensure that it is still functioning. A malfunctioning device will show at the panel as a fault saving time and effort on maintenance inspections*. The needs for VADs will be identified as part of the risk assessment. As with other fire alarm system components, there are a number of challenges that must be considered in the layout design and installation of VADs. One challenge is the illumination of the entire volume of the open space where the alarm must be visible. VADs must produce sufficiently intense light, so that an individual located anywhere in the space, looking either towards or away from the VAD, would be alerted in the event of an emergency. Wall & Ceiling Beacons The control panel can be programmed to perform an automatic daily LED check on our Wall and Ceiling Beacons, consisting of a lower power single flash, recorded by the in-built sensor. This reduces the probability of a failure on demand, just when the device is needed. A failure is indicated at the panel**. Our new Wall and Ceiling Beacons have the ability to be powered externally from a separate 24V power supply. This means for projects that require many VADs the loop current isn’t drained by the LEDs when they are activated (meaning more devices on the loop is possible)**. VADs will now be classified into three categories based on their application: Custom-designed lens W - Wall-mounted C - Ceiling-mounted O - Open Category LED technology Approved to EN54-23, C & W categories Advanced optics ensures superior light coverage at low current draw Synchronised flash exceeds EN54-23 standard Soft start feature reduces power surges during system start-up Available in either red or white casings Available with either a red or white LED Product Model Information Type When in operation, these Beacons monitor the LED light output via a separate sensor to ensure that a flash occurs, again saving time on scheduled walk-tests. A failure to operate is indicated as a fault at the panel**. The performance of VADs under the new standard is now assessed against a minimum required illumination of 0.4 lux on surfaces perpendicular to the direction of the light emitted from the device. Base Models LED Colour Product Colour CWST-RW-S5 White Red CWST-RR-S5 Red Red CWST-WW-S5 White White CWST-WR-S5 Red White Outdoor variants available (used with the wall sounder weatherproofing kit) W and C mounting categories are specified at specific installation heights and particular patterns of coverage - see below for more information. Within these two categories, the shape of the volume covered is fixed by the standard. The dimensions of this coverage volume are specified by the manufacturer. For all categories, the volume covered can be used to determine VAD spacing within the building. W Category (Wall-mounted) Coverage Volume C Category (Ceiling-Mounted) Coverage Volume Wall mounted VADs cover a cuboid volume with a square floor area. The coverage volume is presented as a code in the form of W - X - Y, where W = Wall-mounted category. X is the maximum mounting height (m) and Y is the width and length (m) of the coverage floor area - see diagram. The minimum mounting height allowable by the standard is 2.4m. Ceiling-mounted VADs cover a cylindrical area. The coverage volume is presented as a code in the form C - X - Y, where C = Ceiling-mounted category. X is the maximum mounting height (m) and Y is the diameter (m) of the coverage volume’s floor area - see diagram. The maximum mounting height can only be specified as 3, 6 or 9m. For example Hochiki’s wall-mounting VAD has a classification of W-2.4-5. This means it should be mounted at 2.4m from the floor and will cover an area of up to 5m by 5m output LEDs, advanced optics and an innovative lens design, providing outstanding Omnidirectional light coverage at low current draw. Specifically designed for, and approved to meet EN54-23. CWST-S5 delivers quality, reliability and long operational life. The new Wall and Ceiling Beacons in our new EN54-23 compliant range are available with either red or white LEDs offering additional flexibility to the end-installer when deciding on the requirements of each installation VAD Y X Y ESPintelligent CHQ-CB An Addressable Loop-Powered Beacon, with a high intensity LED and a custom designed free-form optic which produces a highly visible flash. Coverage diameters include 5m, 7.5m, 10m and 15m diameter*. The unit is designed to fit the YBN-R/3, YBN-R/3(SCI), YBO-BS or the YBO-R/(SCI), and is available in Red or White LEDs. Loop Powered Single loop address via TCH-B100 High Intensity LED technology 0.5/1 Hz flash frequency Addressable via TCH-B100 Choice of 2 LED colours (red and white) Approved to EN54-23:2010 Category ‘C’ High efficiency Selectable light output** Operating voltage 17-41 vdc CWST-W5 A Conventional Weatherproof Beacon, which features high output LEDs, advanced optics and an innovative lens design, providing outstanding Omni-directional light coverage at low current draw. Specifically designed for, and approved to meet EN54-23. The CWST-W5 delivers outstanding quality, reliability and long operational life. Weatherproof base provides IP65 for external use applications Product Model Information For example Hochiki’s ceilingmounting VAD has a classification of C-3-15. This means it can be mounted up to 3m from the floor and will cover a cylindrical area of 15m diameter. Type VAD X Ceiling Beacons Base Models LED Colour CHQ-CB/WL White Product Colour Ivory CHQ-CB(WHT)/WL White White CHQ-CB(RED)/WL White Red www.hochikieurope.com/loudandclear > Base Models LED Colour Product Colour CWST-RW-W5 White Red CWST-RR-W5 Red Red CHQ-CB/WL-15 White Ivory CWST-WW-W5 White White CHQ-CB(WHT)/WL-15 White White CWST-WR-W5 Red White CHQ-CB(RED)/WL-15 White Red CHQ-CB/RL Red Ivory CHQ-CB(WHT)/RL Red White CHQ-CB(RED)/RL Red Red *0.5Hz flash frequency white LED **Panel compatibility dependent www.hochikieurope.com/loudandclear > Approved to En54-23, C & W categories Advanced optics ensures superior light coverage at low current draw Synchronised flash exceeds EN54-23 standard Soft start feature reduces power surges during system start up IP65 Available in either red or white casings Available with either a red or white LED Product Model Information Type Y The width of the room is Y/1.414 www.hochikieurope.com/loudandclear > Choosing your VAD CHQ-WB An Addressable Loop-Powered Beacon, with a high intensity LED and a custom designed free-form optic which produces a highly visible flash. The unit is designed to fit the YBN-R/3, YBNR/3(SCI), YBO-BS or the YBO-R/(SCI), and is available in Red or White LEDs. Loop Powered Single loop address via TCH-B100 High Intensity LED technology 0.5/1 Hz flash frequency Addressable via TCH-B100 Choice of 2 LED colours (red and white) Approved to EN54-23:2010 Category ‘W’ High efficiency Selectable light output** Operating voltage 17-41 vdc Type Wall Beacons Base Models LED Colour What type of VAD? Which case colour? Ivory case White case Product Colour CHQ-WB/WL White Ivory CHQ-WB(WHT)/WL White White CHQ-WB(RED)/WL White Red CHQ-WB/RL Red Ivory CHQ-WB(WHT)/RL Red White CHQ-WB(RED)/RL Red Red Red case Wall Sounder Beacon White case Which LED colour? Product White LEDs YBO-BSB2/WL Red LEDs YBO-BSB2/RL White LEDs YBO-BSB2(WHT)/WL Red LEDs YBO-BSB2(WHT)/RL White LEDs CHQ-WSB2/WL Red LEDs CHQ-WSB2/RL White LEDs CHQ-WSB2(WHT)/WL Red LEDs CHQ-WSB2(WHT)/RL EN54-23 Ratings 1 2 3 CHQ-CB/RL O C-3-7.5 C-3-10 CHQ-CB/WL C-3-5 C-3-7.5 C-3-10 CHQ-CB/WL-15 O C-3-10 C-3-15 CHQ-CB(WHT)/RL O C-3-7.5 C-3-10 CHQ-CB(WHT)/WL C-3-5 C-3-7.5 C-3-10 CHQ-CB(WHT)/WL-15 O C-3-10 C-3-15 CHQ-CB(RED)/RL O C-3-7.5 C-3-10 CHQ-CB(RED)/WL C-3-5 C-3-7.5 C-3-10 CHQ-CB(RED)/WL-15 O C-3-10 C-3-15 White LEDs CHQ-WB/WL W-2.4-5 W-2.4-6 W-2.4-7 Red LEDs CHQ-WB/RL O O W-2.4-5 White LEDs CHQ-WB(WHT)/WL W-2.4-5 W-2.4-6 W-2.4-7 Red LEDs CHQ-WB(WHT)/RL O O W-2.4-5 White LEDs CHQ-WB(RED)/WL W-2.4-5 W-2.4-6 W-2.4-7 Red LEDs CHQ-WB(RED)/RL O O W-2.4-5 Red LEDs An Addressable Loop-Powered Base Sounder Beacon, providing 13 volume levels and 51 tones with a maximum output of up to 98 dB(A) (±2 dB(A)) with low current consumption. The unit is designed to fit either the YBN-R/3, YBO-R/SCI Bases. Base Sounder Beacons Loop Powered Single Loop Address, addressed by either Control Panel or TCH-B100 50 ~ 98 dB(A) (±2 dB(A)) output at 1m Fits Hochiki Standard or Isolator Bases and supports ESP Sensors and Remote Indicator 51 User-Selectable Tones (all tones EN54-3 compatible) Beacon and Sounder can be controlled independently** Approved to EN54-23: 2010 Category ‘O’ Operating voltage 17-41 vdc YBO-BSB2/WL White Ivory YBO-BSB2(WHT)/WL White White YBO-BSB/RL Red Ivory YBO-BSB2(WHT)/RL Red White Ivory case White case Red case Ivory case Wall Beacon White case Wall Sounder Beacons Red case White LEDs CDXconventional As per CHQ-WS2 plus: An Addressable Loop-Powered Wall Sounder Beacon, as per the CHQ-WS2 but additionally featuring an integral beacon within the horn which utilises high intensity LED technology. Special bases available: YBO-R/3(RED), YBO-R/ SCI(RED), YBO-R/3(WHT) and YBO-R/ SCI(WHT-SNDR). White LEDs Red LEDs **Panel compatibility dependent CHQ-WSB2 White LEDs Red LEDs Ceiling Beacon A Guide to Our Products ‘O’ Rated **Panel compatibility dependent YBO-BSB2 Variable flash frequency High Intensity LED technology Independent control of Sounder and Beacon Auto-shutdown Mode available - can be set independently for sounder or beacon** Approved to EN54-23: 2010 Category ‘O’ Operating voltage 17-41 vdc CHQ-WSB2/WL White Red CHQ-WSB2(WHT)/WL White White What type of VAD? Which case colour? Red case Standard Base White case Red case Waterproof Base White case CHQ-WSB2/RL Red Red CHQ-WSB2(WHT)/RL Red White **Panel compatibility dependent www.hochikieurope.com/loudandclear > VADs ESPintelligent Base Sounder Beacon Product Model Information Compliant With the wide choice of VAD variants available it might seem a daunting task to identify the best unit for the application. Therefore we have devised this simple configuration table which allows you to source the correct VAD by answering questions and following the branches to the appropriate device variant. Simply select the VAD type, then the case colour and finally the LED colour. The ratings column allows you to check the coverage volume settings available. Coverage volumes are selected via the CIE*. HOCHIKI EUROPE (UK) LIMITED EN54-23 Ratings Which LED colour? Product White LEDs CWST-RW-S5 W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5 Red LEDs CWST-RR-S5 W-2.4-6.2 C-3-9.4 C-6-8.6 - White LEDs CWST-WW-S5 W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5 Red LEDs CWST-WR-S5 W-2.4-6.2 C-3-9.4 C-6-8.6 - White LEDs CWST-RW-W5 W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5 Red LEDs CWST-RR-W5 W-2.4-6.2 C-3-9.4 C-6-8.6 - White LEDs CWST-WW-W5 W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5 Red LEDs CWST-WR-W5 W-2.4-6.2 C-3-9.4 C-6-8.6 - Wall Fitted Ceiling Ceiling Grosvenor Road, Gillingham Business Park, Gillingham, Kent, ME8 0SA, United Kingdom T: +44 (0)1634 260133 F: +44 (0)1634 260132 E: (UK Sales) [email protected] E: (Non UK Sales) [email protected] W: www.hochikieurope.com/loudandclear * Check CIE compatibility ESPintelligent EN54-23 Your Safety, Our Technology Our Products Choosing your VAD CHQ-WB An Addressable Loop-Powered Beacon, with a high intensity LED and a custom designed free-form optic which produces a highly visible flash. The unit is designed to fit the YBN-R/3, YBNR/3(SCI), YBO-BS or the YBO-R/(SCI), and is available in Red or White LEDs. Loop Powered Single loop address via TCH-B100 High Intensity LED technology 0.5/1 Hz flash frequency Addressable via TCH-B100 Choice of 2 LED colours (red and white) Approved to EN54-23:2010 Category ‘W’ High efficiency Selectable light output** Operating voltage 17-41 vdc Type Wall Beacons Base Models LED Colour What type of VAD? Which case colour? Ivory case White case Product Colour CHQ-WB/WL White Ivory CHQ-WB(WHT)/WL White White CHQ-WB(RED)/WL White Red CHQ-WB/RL Red Ivory CHQ-WB(WHT)/RL Red White CHQ-WB(RED)/RL Red Red Red case Wall Sounder Beacon White case Which LED colour? Product White LEDs YBO-BSB2/WL Red LEDs YBO-BSB2/RL White LEDs YBO-BSB2(WHT)/WL Red LEDs YBO-BSB2(WHT)/RL White LEDs CHQ-WSB2/WL Red LEDs CHQ-WSB2/RL White LEDs CHQ-WSB2(WHT)/WL Red LEDs CHQ-WSB2(WHT)/RL EN54-23 Ratings 1 2 3 CHQ-CB/RL O C-3-7.5 C-3-10 CHQ-CB/WL C-3-5 C-3-7.5 C-3-10 CHQ-CB/WL-15 O C-3-10 C-3-15 CHQ-CB(WHT)/RL O C-3-7.5 C-3-10 CHQ-CB(WHT)/WL C-3-5 C-3-7.5 C-3-10 CHQ-CB(WHT)/WL-15 O C-3-10 C-3-15 CHQ-CB(RED)/RL O C-3-7.5 C-3-10 CHQ-CB(RED)/WL C-3-5 C-3-7.5 C-3-10 CHQ-CB(RED)/WL-15 O C-3-10 C-3-15 White LEDs CHQ-WB/WL W-2.4-5 W-2.4-6 W-2.4-7 Red LEDs CHQ-WB/RL O O W-2.4-5 White LEDs CHQ-WB(WHT)/WL W-2.4-5 W-2.4-6 W-2.4-7 Red LEDs CHQ-WB(WHT)/RL O O W-2.4-5 White LEDs CHQ-WB(RED)/WL W-2.4-5 W-2.4-6 W-2.4-7 Red LEDs CHQ-WB(RED)/RL O O W-2.4-5 Red LEDs An Addressable Loop-Powered Base Sounder Beacon, providing 13 volume levels and 51 tones with a maximum output of up to 98 dB(A) (±2 dB(A)) with low current consumption. The unit is designed to fit either the YBN-R/3, YBO-R/SCI Bases. Base Sounder Beacons Loop Powered Single Loop Address, addressed by either Control Panel or TCH-B100 50 ~ 98 dB(A) (±2 dB(A)) output at 1m Fits Hochiki Standard or Isolator Bases and supports ESP Sensors and Remote Indicator 51 User-Selectable Tones (all tones EN54-3 compatible) Beacon and Sounder can be controlled independently** Approved to EN54-23: 2010 Category ‘O’ Operating voltage 17-41 vdc YBO-BSB2/WL White Ivory YBO-BSB2(WHT)/WL White White YBO-BSB/RL Red Ivory YBO-BSB2(WHT)/RL Red White Ivory case White case Red case Ivory case Wall Beacon White case Wall Sounder Beacons Red case White LEDs CDXconventional As per CHQ-WS2 plus: An Addressable Loop-Powered Wall Sounder Beacon, as per the CHQ-WS2 but additionally featuring an integral beacon within the horn which utilises high intensity LED technology. Special bases available: YBO-R/3(RED), YBO-R/ SCI(RED), YBO-R/3(WHT) and YBO-R/ SCI(WHT-SNDR). White LEDs Red LEDs **Panel compatibility dependent CHQ-WSB2 White LEDs Red LEDs Ceiling Beacon A Guide to Our Products ‘O’ Rated **Panel compatibility dependent YBO-BSB2 Variable flash frequency High Intensity LED technology Independent control of Sounder and Beacon Auto-shutdown Mode available - can be set independently for sounder or beacon** Approved to EN54-23: 2010 Category ‘O’ Operating voltage 17-41 vdc CHQ-WSB2/WL White Red CHQ-WSB2(WHT)/WL White White What type of VAD? Which case colour? Red case Standard Base White case Red case Waterproof Base White case CHQ-WSB2/RL Red Red CHQ-WSB2(WHT)/RL Red White **Panel compatibility dependent www.hochikieurope.com/loudandclear > VADs ESPintelligent Base Sounder Beacon Product Model Information Compliant With the wide choice of VAD variants available it might seem a daunting task to identify the best unit for the application. Therefore we have devised this simple configuration table which allows you to source the correct VAD by answering questions and following the branches to the appropriate device variant. Simply select the VAD type, then the case colour and finally the LED colour. The ratings column allows you to check the coverage volume settings available. Coverage volumes are selected via the CIE*. HOCHIKI EUROPE (UK) LIMITED EN54-23 Ratings Which LED colour? Product White LEDs CWST-RW-S5 W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5 Red LEDs CWST-RR-S5 W-2.4-6.2 C-3-9.4 C-6-8.6 - White LEDs CWST-WW-S5 W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5 Red LEDs CWST-WR-S5 W-2.4-6.2 C-3-9.4 C-6-8.6 - White LEDs CWST-RW-W5 W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5 Red LEDs CWST-RR-W5 W-2.4-6.2 C-3-9.4 C-6-8.6 - White LEDs CWST-WW-W5 W-2.4-9.0 C-3-9.5 C-6-9.5 C-9-9.5 Red LEDs CWST-WR-W5 W-2.4-6.2 C-3-9.4 C-6-8.6 - Wall Fitted Ceiling Ceiling Grosvenor Road, Gillingham Business Park, Gillingham, Kent, ME8 0SA, United Kingdom T: +44 (0)1634 260133 F: +44 (0)1634 260132 E: (UK Sales) [email protected] E: (Non UK Sales) [email protected] W: www.hochikieurope.com/loudandclear * Check CIE compatibility ESPintelligent EN54-23 Your Safety, Our Technology Our Products