Blower DOG-1 Drying the firefight hoses Drying the humid walls Fresh air supply during rescue actions Application DOG-1 blower jest meant for: – local drying the walls in humid rooms, – drying the inner surface of the firefight hoses at fire brigades, – supplying fresh air during rescue actions to places without ventilation; Fresh air can be conveyed within a distance even of several dozens metres; The device can deliver fresh air for even 10 people. Lightweight structure and quick-connectors for hose attachment make the device very easy in use. High-pressure blower Structure The blower consists of a housing and a high-pressure turbine. The housing is equipped with a handle to carry the device from one place to another. On the upper housing surface is located a motor switch to operate the turbine. The appliance is equipped with a standard quick-connector to attach the hoses. The outlet air is warmed up by 35°C. The blower is equipped with a five-metre-long power supply cable, ended with a plug. Operational use In application of room drying, PUT the blower outlet in distance of approx. twenty centimetres from the humid wall and depending on the drying PROGRESS change the blower position. It is recommended that there is fresh air supply to the dried room. Provided that there is applied a flexible hose fastened through a quick-connector at the device outlet, the blower can be placed in another room or outside the building. The hose tip can precisely remove humidity, even from the most inaccessible places. In larger rooms, it is recommended to apply several blowers DOG-1, whereby each of them is directed with outlet to an another wall. For firefight hose drying, connect it through a quick-connector. If the DOG-1 blower is used for air supplying to disastrously cut-off people (during the rescue action), connect through a quick-connector the firefight hose or a flexible hose and place its outlet in a place allowing a free air access. 146 Technical Data Type DOG-1 Part.No 843W27 Supply voltage [V] Motor rate of the turbine [kW] Volume flow [m³/h] 230 1,6 225 Maximum pressure [Pa] 30 000 PAcoustic pressure level [dB(A)] from distance 1m 5m 81 78 7 150 247 286 Weight [kg] Additional equipment Hose Type Part.No Weight [kg/m] Remarks PCV FLEX-44 421P35 0,36 Flexible extraction hose. Standard length – 15 metres. Technical data – see section “Ventilation Accessories”. Type Part.No Weight [kg] Remarks KR-DOG 830Z22 0,6 To connect the PVC FLEX-44 flexible hose with the DOG-1 blower. Conneciton High-pressure blower 147 Blower WW WW-2-1-1100 motor rate [W] sort of the impeller blower size blower type Application The high-pressure blowers are used for conveying the air in conditions where is required high pressure or underpressure. Blowers can be applied in industrial vacuum cleaners, filtering units of high underpressure, in aeration the water reservoirs (sewage-treatment plants) as well as to create an “air geyser” in pools. Structure The blower consists of a housing, aluminium cast radial impeller, two silencers and a motor. The impeller is installed directly on the motor shaft. Silencers are installed at the inlet and outlet. The device is adapted for work both in horizontal and vertical position. High-pressure blower Conditions of use: – admissible temperature of the intake air +40°C, – The fan cannot convey viscous impurities and substances of explosion risk and of dustiness exceeding 0,3 g/m³. Technical data Designation of the blower Part No. Supply voltage [V] Synchronous rotations [1/min] Motor rate [kW] Maximum volume flow [m³/h] Noise level [dB(A)] Ingress protection IP Weight [kg] WW-2-1-1100 843W20 230 3000 1,1 180 80 54 25 WW-2-1-1100 843W19 3 × 400 3000 1,1 180 80 54 25 WW-3-1-3000 843W21 3 × 400 3000 3,0 300 81 54 39 WW-4-1-7500 843W22 3 × 400 3000 7,5 600 87 54 74 148 Example of application of the high-pressure blower as an air geyser outlet inlet view W view Z 3 holes spaced 120˚ H – depth of the thread Technical data Type A B C D E F G H I J K L WW-2-1-1100 637 378 368 265 400 60 M6 15 118 105 50 110 WW-3-1-3000 637 393 393 270 400 60 M8 18 128 132 50 110 WW-4-1-7500 670 482 482 350 400 60 M8 20 144 160 50 110 total pressure [mbar] total pressure [mbar] suction air supply volume flow [m³/h] volume flow [m³/h] 149 High-pressure blower Flow charts Blower PODRYW-450/K Application example of the blower for room wall drying Application The PODRYW blower is used in following applications: tUFNQPSBSZBJSTVQQMZGPSSPPNTBOEXPSLQMBDFT tUPTVQQMZBJSTUSFBNUPQFPQMFCFJOHJOSPPNTBOETQBDFTPGJODSFBTFEUFNQFSBUVSFUPJNQSPWFUIFSNBMDPNGPSU tBJSTVQQMZPOUPIPUPCKFDUTUPDIJMMEPXOUIFJSUFNQFSBUVSF tUPDSFBUFBSUJöDJBMXJOECMPXOPOUPPCKFDUTEVSJOHöMNTIPPUJOHPSQIPUPHSBQIJDTFTTJPOTPSGPSBEWFSUJTFNFOU purposes, to visualize the air motion, tESZJOHUIFIVNJEXBMMTPGBSPPN The blower can be used in various areas: production halls, television and advertisement studios, utility rooms, storehouses, etc. Structure Low-pressure blower PODRYW consists of an axial fan mounted rotary in a framework. Due to this, the fan can be turned around the horizontal axis and it can be fixed in the requested position. On the square housing is a rotation governor to switch on the fan and to adjust the fan flow efficiency. The blower is equipped with a five-metre-long power supply cable, ended with a plug. Put the blower outlet in a distance of 50 cm parallel to the wall. Drying proceeds due to high flow efficiency of the blower, but at low pressure, therefore the drying effect is obtained by blowing off the close-to-wall layer only. Important is to provide unrestricted fresh air to the dried room, by creating a natural air draught inside. Due to low noise and small power consumption, the blower can work continuously, not being an inconvenience to surroundings. Technical data Type Part No. Volume flow [m³/h] Supply voltage [V] Nominal rotations [1/min] Motor rate [W] Maximum temperature in the work area [°C] Noise level in distance of 5m [dB(A)] Weight [kg] PODRYW-450/K 807W62 4500 230 1400 245 40 66 17,5 150
Similar documents
axial portable fans - PODRYW
supply cable, ended with a plug. Put the blower outlet in a distance of 50 cm parallel to the wall. Drying proceeds due to high flow efficiency of the blower, but at low pressure, therefore the dry...
More information