ALSTOM RELAY PRODUCT RANGE

Transcription

ALSTOM RELAY PRODUCT RANGE
ALSTOM RELAY
PRODUCT RANGE
Jakarta
February 2014
GRID
Substation Automation Solutions
Offer
Transmission & Primary Distribution
From 10 kV to 1000+ kV
MU Agile AMU
MiCOM P40 Agile
MiCOM & IEDs
Control Systems
Projects & Engineering
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Support
A Proud History
M O DE L
No
KC G G 140
S Y S M od e l N o .
K C G G 14 0 M
F E D C B A 9 8 7 6 5 4 3 2 1 0
T RIP
A L AR M
F
Historical milestones
In
CDG
MCGG
P h+
A Vx
+
-
0
Hz
V
K
P14x
• 1949 - Relay development started in Stafford
• 1952 - 1st Induction Disc overcurrent relay [CDG]
• 1960 - Stafford site opened
• 1982 - 2nd generation of digital protection (MIDOS MCGG)
Agile
• 1999 - 3rd generation of numerical products (MiCOM)
• 2002 - 1st PACiS Digital Control Sys
commissioned in UK
• 2007 - Certification Labs. receive
ILAC accreditation
• 2009 - UCA International
accredit for IEC 61850
conformance testing
1918
English
Electric
1968
GEC
1989
GEC
ALSTHOM
1998
2004
ALSTOM
T&D
AREVA
T&D
2010
ALSTOM
GRID
Almost 100 years experience
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
P3
ALSTOM GRID Protection Covers all Areas of your
Power System
Generation
P940
Transmission
P340
P640
P740
P140
P440
P540
P340
P140
P640
Industry
P640
P240
P640
Distribution
C264P
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
P140
P140
Substation Automation Solutions
Portfolio and offering
Numerical Protection Relays
MiCOM Alstom Px40
Digital Control System
DS Agile incl. C264
MiCOM Px40 Agile
Feeder Management
Substation Digitalization
DAP Server (ASAT)
Digital Protection Relays
MiCOM Alstom Px40-9.2
Control Switches
P847 Phasor Measurement Unit
Mx70 Measurement
Legacy DCS
SPACE2000, PSCN, PACiS
Electromechanical
Hinged Armature relays
Conventional Control
Protection panels
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
MiCOM Alstom
Complete Protection Range
Px90
Interfaces &
Accessories
C264P
Feeder
One-Box
Solution
P840
P140
Autoreclose
Relays & PMU
Feeder
Management
Relays
P740
P240
Busbar
Protection
Relays
Universal Motor
Protection
P640
P340
Transformer
Protection
Relays
Generator
Protection
Relays
P540
Line
Differential
Relays
P440
Distance
Protection
Relays
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
• Comprehensive Range
• Fault Analysis Tools
• Programmability
• Customisation
• Instrumentation
• Self Diagnostics &
• Commissioning Tools
• Communications
• Bay Monitoring & Control
IEC61850, Cyber Security
Redundant Ports
MiCOM S1 Agile
Device Configuration
• Setting file and logic creation, editing and transfer to and from the IEDs.
• Management of events and disturbance records
System Explorer
•
•
Displays a virtual system of the
managed devices.
System is graphically displayed as
tree with different nodes referred
as elements (system, substations,
voltage levels, bays, etc.,)
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Product
Selection
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Overcurrent & Voltage Feeder Relays
Selector
No
START
P14NB
with Auto Reclose
Rear
Ethernet Port(s)
Required?
Yes
None
Non Directional
Overcurrent Only ?
With Downed
Conductor
Detection ?
Yes
No
P14NZ
(SEF CT only)
No Auto Reclose
Single
Dual
Redundant
Yes
Voltage Inputs
Only ?
See P14x Advanced
Feeder Management
Yes
P94VP
No
No
P14x
Check
Synchronism
required?
P94VB
No
Auto Reclose
and Fault Locator
Required ?
P14DB
Yes
P14DZ
(SEF CT only)
Yes
With Downed
Conductor
Detection ?
P14DL
No
Product selector - 08.2010 - P 14
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Advanced Feeder Management
Selector
START
With voltage vector
Shift & dynamic line rating
?
No
Distributed Generation
Interconnection
Feeder Protection
No
One box solution
With mimic diagram
?
8 binary inputs
+8 relay contacts
Sufficient ?
P341
Yes
C264P
Yes
Feeder relay with
Integrated bay control
No
Autoreclose
required?
Yes
P145
Yes
Function keys for
control & test operations
Required?
No
Yes
No
Feeder Management
Relay with autoreclose,
Check synchronism
& Function keys
Check
Synchronism
Required?
P141
Feeder management
relay
P142
Feeder management
Relay with autoreclose
Product selector - 08.2010 - P 15
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
P143
No
Yes
Feeder management
Relay with autoreclose
& check synchronism
Motor Protection
No
P241
Motor Management
relay
START
Yes
Is motor rated
power ≤ 1 MW ?
Function keys for
control & test operations
Required?
P242
No
(> 1MW)
Motor Management
relay
Yes
No
With differential
Protection?
Yes
P243
Motor Management
Relay with Differential
Product selector - 08.2010 - P 16
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Generator Protection
START
Small generators
(<1.5MVA)
Yes
With
underimpedance,
loss of field
Protection?
No
With Voltage vector
Shift & Dynamic
Line Rating
P341
Yes
P14DG
No
Yes
No
P342
Yes
Medium size generators
(1.5
(1.5-10MVA)
or back-up
up protection
for large generators
No
With differential?
100% stator
earth fault, pole slipping
dead machine?
Yes
Yes
P343
No
No
P346
Economy model
Large Generators
(>10MVA)
Yes
With 100%
stator earth fault via low
frequency injection?
Yes
P345
No
With 100% stator
earth fault, pole slipping,
dead machine ?
Yes
No
Product selector - 08.2010 - P 17
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
With differential & 2x
neutral voltage inputs for earth
fault and interturn
protection?
No
Yes
P344
P346
(With differential &
1 neutral voltage input
for earth fault)
Distance Protection
START
Quad
Typical
Characteristic
Preference?
Mho
No
Sub-cycle
Distance required?
Yes
Yes
Sub-cycle
Sub
cycle Distance
Required?
Yes
No
Yes
Yes
Single-Pole
Tripping required?
P446
Sub-cycle dual CB
quad/Mho distance
Relay with single-pole
autoreclose
No
8 Opto-inputs
Opto inputs &
14 output contacts
Sufficient?
No
16 Opto-inputs
Opto inputs &
21 output contacts
Sufficient?
P441
Full-Scheme quad.
Distance for 3 Pole
ProductTripping
selector - 08.2010 - P 18
Yes
P442
P444
Full-scheme quad.
Distance relay with
Single pole Recloser
Distance relay with
Single pole A/R and
Extended I/O
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
No
No
P445
P443
No
Yes
Dual Circuit
Breaker Feeding
Arrangement?
Single-Pole
Tripping required?
Sub-cycle quad/mho
Distance relay with
Single-pole A/R
Economy distance
for Subtransmission
& Distribution
Line & Cable Differential
START
Yes
Dual CB
configuration?
More than 16 digital inputs
and 14 output contacts?
Yes
No
No
Yes
P544
Compatible with
SDH/SONET networks?
Dual CB Differential with
Optional Distance
P545
Differential / Distance
With Extended Binary I/O
P546
No
Dual CB Diff. / Distance
With Extended Binary I/O
With IEC61850 and
Function Keys?
P541
Yes
Yes
More than 16 digital inputs
and 24 output contacts?
Economy Model
No
No
With Auto Reclose?
No
Yes
With Voltage Inputs,
Optional Distance
Protection?
P542
Product selector - 08.2010 - P 19
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
No
Yes
P543
Differential with
Optional Distance
Phase Comparison Protection
START
Application Requires
Distance Protection?
Yes
No
Yes
With IEC61850?
P547
Advanced Model Phase
Comparison with Distance
in 80TE case
No
With Function
Keys?
Yes
No
P547
Phase Comparison with
8 binary inputs &
8 relay contacts in
40TE case
No
Yes
More than 8 digital inputs
and 8 output contacts?
Product selector - 08.2010 - P 20
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Transformer Protection
START
Yes
Is any winding
Supplied by more
than 1 Circuit
Breaker?
2 winding
3 winding
Type of Transformer?
No
3 phase
Voltages required
for measurement, protection,
Directionalising,
records?
Yes
Is any winding
Supplied by more
than 1 Circuit
Breaker?
No
Auto Transformer
P643
P642
No
Transformer Protect.
For 2-End Schemes
With or without
Tertiary winding?
With
P643
Without
One
Dual Breaker feeding
One or both sides of
transformer?
Both
P645
Yes
Is any winding
Supplied by more
than 1 Circuit
Breaker?
No
P643
Transformer Protect.
For up to 3 Ends
Product selector - 08.2010 - P 21
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Yes
P645
Transformer Protect.
For up to 5 Ends
P645
Busbar Protection
START
Low impedance
(Biased)
How many
Discrete protection
Zones?
Technology
Preference?
3 or
more
Economy
Distribution
Scheme
1 or 2
P14*
Feeder Management
Relays Used in Interlock
(Blocking) Scheme
Number of feeder,
Coupler, and section
breakers
Up to
18
P746
Busbar Differential for
Small Schemes
More
than 18
P74* Scheme
P741 Central Unit
P742 Peripheral Unit
P743 Peripheral Unit
Product selector - 08.2010 - P 22
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
High impedance
P14*
Numerical
Relay(s)
Required?
Yes
Feeder Management
Relay Used in High
Impedance mode
with Varistor
No
Preferred
Operating
principle
Voltage
Pickup
MFAC34
High Impedance, Voltage
Calibrated ElectroMechanical Relay
Current
Pickup
MCAG34
High Impedance, Current
Calibrated ElectroMechanical Relay
Autoreclose & Breaker Fail
START
UK Mesh Corner
Application ?
P842
Yes
Mesh corner Autoreclose
Scheme for Three Pole
Tripping
No
No
16 opto-inputs
opto inputs and
14 output contacts
sufficient?
Dual Circuit Breaker
Configuration ?
Yes
No
Yes
P841 model A
P841 model B
Single CB control, reclose,
Check synchronising and
back-up protection
Model for dual breaker,
ring bus, and breaker
and a half feeding
Product selector - 08.2010 - P 23
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
www.alstom.com
www.alstom.com/grid/sas
GRID