ALSTOM RELAY PRODUCT RANGE
Transcription
ALSTOM RELAY PRODUCT RANGE
ALSTOM RELAY PRODUCT RANGE Jakarta February 2014 GRID Substation Automation Solutions Offer Transmission & Primary Distribution From 10 kV to 1000+ kV MU Agile AMU MiCOM P40 Agile MiCOM & IEDs Control Systems Projects & Engineering © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Support A Proud History M O DE L No KC G G 140 S Y S M od e l N o . K C G G 14 0 M F E D C B A 9 8 7 6 5 4 3 2 1 0 T RIP A L AR M F Historical milestones In CDG MCGG P h+ A Vx + - 0 Hz V K P14x • 1949 - Relay development started in Stafford • 1952 - 1st Induction Disc overcurrent relay [CDG] • 1960 - Stafford site opened • 1982 - 2nd generation of digital protection (MIDOS MCGG) Agile • 1999 - 3rd generation of numerical products (MiCOM) • 2002 - 1st PACiS Digital Control Sys commissioned in UK • 2007 - Certification Labs. receive ILAC accreditation • 2009 - UCA International accredit for IEC 61850 conformance testing 1918 English Electric 1968 GEC 1989 GEC ALSTHOM 1998 2004 ALSTOM T&D AREVA T&D 2010 ALSTOM GRID Almost 100 years experience © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. P3 ALSTOM GRID Protection Covers all Areas of your Power System Generation P940 Transmission P340 P640 P740 P140 P440 P540 P340 P140 P640 Industry P640 P240 P640 Distribution C264P © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. P140 P140 Substation Automation Solutions Portfolio and offering Numerical Protection Relays MiCOM Alstom Px40 Digital Control System DS Agile incl. C264 MiCOM Px40 Agile Feeder Management Substation Digitalization DAP Server (ASAT) Digital Protection Relays MiCOM Alstom Px40-9.2 Control Switches P847 Phasor Measurement Unit Mx70 Measurement Legacy DCS SPACE2000, PSCN, PACiS Electromechanical Hinged Armature relays Conventional Control Protection panels © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. MiCOM Alstom Complete Protection Range Px90 Interfaces & Accessories C264P Feeder One-Box Solution P840 P140 Autoreclose Relays & PMU Feeder Management Relays P740 P240 Busbar Protection Relays Universal Motor Protection P640 P340 Transformer Protection Relays Generator Protection Relays P540 Line Differential Relays P440 Distance Protection Relays © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. • Comprehensive Range • Fault Analysis Tools • Programmability • Customisation • Instrumentation • Self Diagnostics & • Commissioning Tools • Communications • Bay Monitoring & Control IEC61850, Cyber Security Redundant Ports MiCOM S1 Agile Device Configuration • Setting file and logic creation, editing and transfer to and from the IEDs. • Management of events and disturbance records System Explorer • • Displays a virtual system of the managed devices. System is graphically displayed as tree with different nodes referred as elements (system, substations, voltage levels, bays, etc.,) © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Product Selection © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Overcurrent & Voltage Feeder Relays Selector No START P14NB with Auto Reclose Rear Ethernet Port(s) Required? Yes None Non Directional Overcurrent Only ? With Downed Conductor Detection ? Yes No P14NZ (SEF CT only) No Auto Reclose Single Dual Redundant Yes Voltage Inputs Only ? See P14x Advanced Feeder Management Yes P94VP No No P14x Check Synchronism required? P94VB No Auto Reclose and Fault Locator Required ? P14DB Yes P14DZ (SEF CT only) Yes With Downed Conductor Detection ? P14DL No Product selector - 08.2010 - P 14 © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Advanced Feeder Management Selector START With voltage vector Shift & dynamic line rating ? No Distributed Generation Interconnection Feeder Protection No One box solution With mimic diagram ? 8 binary inputs +8 relay contacts Sufficient ? P341 Yes C264P Yes Feeder relay with Integrated bay control No Autoreclose required? Yes P145 Yes Function keys for control & test operations Required? No Yes No Feeder Management Relay with autoreclose, Check synchronism & Function keys Check Synchronism Required? P141 Feeder management relay P142 Feeder management Relay with autoreclose Product selector - 08.2010 - P 15 © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. P143 No Yes Feeder management Relay with autoreclose & check synchronism Motor Protection No P241 Motor Management relay START Yes Is motor rated power ≤ 1 MW ? Function keys for control & test operations Required? P242 No (> 1MW) Motor Management relay Yes No With differential Protection? Yes P243 Motor Management Relay with Differential Product selector - 08.2010 - P 16 © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Generator Protection START Small generators (<1.5MVA) Yes With underimpedance, loss of field Protection? No With Voltage vector Shift & Dynamic Line Rating P341 Yes P14DG No Yes No P342 Yes Medium size generators (1.5 (1.5-10MVA) or back-up up protection for large generators No With differential? 100% stator earth fault, pole slipping dead machine? Yes Yes P343 No No P346 Economy model Large Generators (>10MVA) Yes With 100% stator earth fault via low frequency injection? Yes P345 No With 100% stator earth fault, pole slipping, dead machine ? Yes No Product selector - 08.2010 - P 17 © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. With differential & 2x neutral voltage inputs for earth fault and interturn protection? No Yes P344 P346 (With differential & 1 neutral voltage input for earth fault) Distance Protection START Quad Typical Characteristic Preference? Mho No Sub-cycle Distance required? Yes Yes Sub-cycle Sub cycle Distance Required? Yes No Yes Yes Single-Pole Tripping required? P446 Sub-cycle dual CB quad/Mho distance Relay with single-pole autoreclose No 8 Opto-inputs Opto inputs & 14 output contacts Sufficient? No 16 Opto-inputs Opto inputs & 21 output contacts Sufficient? P441 Full-Scheme quad. Distance for 3 Pole ProductTripping selector - 08.2010 - P 18 Yes P442 P444 Full-scheme quad. Distance relay with Single pole Recloser Distance relay with Single pole A/R and Extended I/O © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. No No P445 P443 No Yes Dual Circuit Breaker Feeding Arrangement? Single-Pole Tripping required? Sub-cycle quad/mho Distance relay with Single-pole A/R Economy distance for Subtransmission & Distribution Line & Cable Differential START Yes Dual CB configuration? More than 16 digital inputs and 14 output contacts? Yes No No Yes P544 Compatible with SDH/SONET networks? Dual CB Differential with Optional Distance P545 Differential / Distance With Extended Binary I/O P546 No Dual CB Diff. / Distance With Extended Binary I/O With IEC61850 and Function Keys? P541 Yes Yes More than 16 digital inputs and 24 output contacts? Economy Model No No With Auto Reclose? No Yes With Voltage Inputs, Optional Distance Protection? P542 Product selector - 08.2010 - P 19 © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. No Yes P543 Differential with Optional Distance Phase Comparison Protection START Application Requires Distance Protection? Yes No Yes With IEC61850? P547 Advanced Model Phase Comparison with Distance in 80TE case No With Function Keys? Yes No P547 Phase Comparison with 8 binary inputs & 8 relay contacts in 40TE case No Yes More than 8 digital inputs and 8 output contacts? Product selector - 08.2010 - P 20 © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Transformer Protection START Yes Is any winding Supplied by more than 1 Circuit Breaker? 2 winding 3 winding Type of Transformer? No 3 phase Voltages required for measurement, protection, Directionalising, records? Yes Is any winding Supplied by more than 1 Circuit Breaker? No Auto Transformer P643 P642 No Transformer Protect. For 2-End Schemes With or without Tertiary winding? With P643 Without One Dual Breaker feeding One or both sides of transformer? Both P645 Yes Is any winding Supplied by more than 1 Circuit Breaker? No P643 Transformer Protect. For up to 3 Ends Product selector - 08.2010 - P 21 © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Yes P645 Transformer Protect. For up to 5 Ends P645 Busbar Protection START Low impedance (Biased) How many Discrete protection Zones? Technology Preference? 3 or more Economy Distribution Scheme 1 or 2 P14* Feeder Management Relays Used in Interlock (Blocking) Scheme Number of feeder, Coupler, and section breakers Up to 18 P746 Busbar Differential for Small Schemes More than 18 P74* Scheme P741 Central Unit P742 Peripheral Unit P743 Peripheral Unit Product selector - 08.2010 - P 22 © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. High impedance P14* Numerical Relay(s) Required? Yes Feeder Management Relay Used in High Impedance mode with Varistor No Preferred Operating principle Voltage Pickup MFAC34 High Impedance, Voltage Calibrated ElectroMechanical Relay Current Pickup MCAG34 High Impedance, Current Calibrated ElectroMechanical Relay Autoreclose & Breaker Fail START UK Mesh Corner Application ? P842 Yes Mesh corner Autoreclose Scheme for Three Pole Tripping No No 16 opto-inputs opto inputs and 14 output contacts sufficient? Dual Circuit Breaker Configuration ? Yes No Yes P841 model A P841 model B Single CB control, reclose, Check synchronising and back-up protection Model for dual breaker, ring bus, and breaker and a half feeding Product selector - 08.2010 - P 23 © ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. www.alstom.com www.alstom.com/grid/sas GRID