DEWETRON D310 brochure
Transcription
DEWETRON D310 brochure
Automotive Energy & Power Analysis Aerospace Tr a n s p o r t a t i o n G e n e r a l Te s t & M e a s u r e m e n t DEWETRON D300 SERIES D300 series instruments Ultra-p ortable Data Acquisition With the D300 series we take the D310 and shrink the form factor down to the smallest possible size without giving up power or performance. Key Features Ultra-portable data acquisition instruments Choice of ORION series A/D card(s) The D300 can hold either 16 x MDAQ series DIFFERENTIAL signal conditioning channels, or up to 32 channels of direct voltage inputs up to ±10V. And when we install an ORION series A/D card, you’ve got synchronous counter/encoder inputs, plus digital input and output lines automatically, and either two or four optional CAN BUS interfaces. Fast data streaming up to 105 MB/s to SSD A 10” touchscreen display is built into the top cover of the D300 and D303 models, and it’s optional in the D3PC computer only model. The power input is a wide range DC that is perfect for mobile and in-vehicle applications. Includes SSD for the OS and 500 GB HDD for data The computer is the same powerful Intel i7 processor found in the other D series models made in the USA: D310, D510, and the D610. There are two PCI slots inside, which allows for one of our interface cards to be installed in addition to the ORION card, allowing you to add ARINC 429, MIL-STD-1553, or perhaps an analog OUTPUT card to your D300 system. Available from 8 to 32 channels Turn-key software or develop your own Up to 8 synchronous counter inputs Optional CAN BUS, ARINC 429, MIL-STD-1553 Optional video cameras and inertial sensors Tough shipping case included (except D3PC) MIL-STD construction Made in USA Full year warranty Online Information www.dewamerica.com/D300 www.dewam eri ca. com 1 D300 SERIES D300 Overview (with MDAQ conditioners) 10” touchscreen display (INSIDE) Optional interfaces for ARINC, 1553, CAN, IRIG, GPS, etc. DEWETRON (INSIDE) ORION series A/D card Cooling system with externally accessible filters Any two MDAQ-SUB 8 channel conditioners Video cameras like: DEWE-CAM-FW-70 DEWE-CAM-GIG-E-120 DEWE-CAM-USB, etc. EPAD2 signal conditioners for adding slow thermocouple inputs, RTDs, voltages, and currents (daisy-chain) Hard tie-down points 9-29 VDC power input connector High-impact rubberized side / corner protectors Computer interfaces (ethernet, USB 3.0, USB 2,0, video, audio) 2 PCI card edge access (for ORION and interface cards) TWIN Removable 2.5” drives: 120 GB SSD (C) 500 GB HDD (D) www.de wame ric a .com/ D300 D300 System Specs Portable, powerful, tough Flexible signal conditioning 100% modular design Wide range DC input SureHAND basic specifications D300 with MDAQ conditioners Any two of our 8-channel MDAQ-SUB conditioners N/A 16 32 (when either two 16 ch ORION cards are installed, or one 32 ch ORION card is installed, plus the correct number of BNC panels) Maximum analog input channels D303 with Direct ORION inputs DEWETRON Input specifications MDAQ-SUB positions Main system Total PCI slots 2 x half-length PCI slots (optionally converted to 2 x PCIe slots) Hard disk Removable 120 GB SSD (C) and removable 500 GB HDD (D) (both can be upgraded) Data throughput to disk 50 MB/s typical; up to 105 MB/s using SSD 240 GB iMLC Power supply 9~29 VDC. Includes external AC/DC power adapter. 10” XGA display, 1024 x 768 px, with resistive touchscreen (std. in D300 and D303, optional in D3PC) Processor D300 SERIES Display Intel i7 2.0 GHz CPU, on a standard industrial grade MiniITX mainboard RAM 8 GB standard Ethernet 3 x ethernet interfaces (1 Gb) USB interfaces 4 x USB 3.0 ports AND 2 x USB 2.0 ports Display output ports 2 x DisplayPorts and 1 x DVI output for connecting an external display Operating system Microsoft Windows7™ Professional, 64-bit operating system Dimensions (W x D x H) 11.5W x 10.3D x 4.5H (inches) / 292 x 261.6 x 114.3 (mm) (without bumpers) Weight 6 kg typical (13.2 lbs) PCI slots 2 (one of them is normally used by the A/D card) Environmental specifications Operating temperature -20 to 50°C (storage temperature -20 to 60°C) Humdity 10 to 80% non-condensing, 5 to 95% relative humidity Vibration MIL-STD-810F, EN 60068-2-6, EN 60721-3-2 class 2M2 Shock MIL-STD-810F, EN 60068-2-27 Required to complete this model Conditioners: A/D card(s) Software Any two MDAQ-SUB modules N/A (direct inputs wired to BNCs from the A/D card(s) 8 channel cards: ORION-1624-200 series, ORION-0816-5M series, ORION-0816-10M series 16 channel cards: ORION-1616-100 series, ORION-1622-100 series, ORION-1616-1000 series 32 channel cards: ORION-3216-100 series, ORION-3222-100 series Turn-key software package: DS-7-SE or higher 32 analog channels, or multiple video cameras, or DEWE-CAM-FW-70, or DEWE-CLOCK use requires upgrade to PROF edition. 64 analog channels requires upgrade to DSA edition. LabVIEW VIs are available for Dewetron ORION series A/D cards Popular upgrades Synchronization interface (ORION-SYNC) Installs the SYNC hardware input/output ports and LED indicators onto the mainframe. Allows systems with the same base ORION card to be synced. Additionally Requires DS-OPT-NET software option for synchronization under DS-7 software. Digital Isolation (ORION-BASE-DI-ISO) HDD upgrade to solid state disks Isolation for the 16 digital inputs of ORION base cards. Input low: 0 - 2 V, Input high: 3 - 50 V bandwidth: DC up to 1MHz Isolation voltage between channels: 150 VDC, Isolation voltage between Input and Output: 250 VDC Connector: DSUB-37 connector (replaces standard digital I/O connector) HDD-UP-SSD-120 HDD-UP-SSD-240 HDD-UP-SSD-480 Upgrade to 120 GB flash disk (replaces standard spinning hard disk), $ no moving parts, max. data throughput 90 MB/s Upgrade to 240 GB flash disk (replaces standard spinning hard disk), $ no moving parts, max. data throughput 90 MB/s Upgrade to 480 GB flash disk (replaces standard spinning hard disk), $ no moving parts, max. data throughput 100 MB/s Popular interface add-ons CAN expansion IRIG / GPS time code (DEWE-CLOCK-EXT) Adds 2 synchronous high speed CAN bus interfaces to the ORION card inside the system. Includes two DB9 factory installed connectors for these counters on the side panel of the D310, and rear panel of the DEWE-3040 and DEWE-3050. Includes DS-OPT-CAN software option supporting CAN BUS interface. IRIG or GPS synchronized clock source for DEWETRON systems, installed inside a new DEWETRON base unit Input: IRIG signal code A or B, AM or DC, or GPS signal Output: TTL clock from 10 Hz to 10 MHz, PPS and ORION-DSA-SYNC, IRIG-B DC (requires DS-PROF or higher) Please order GPS antenna GPS-ANT-1 or -2separately (if GPS is needed) VIDEO-FG-4 Adds a four channel VIDEO INPUT PCI card to the system. Four BNCs for analog NTSC video input on the right side panel, allowing four video streams to be recorded in sync with the data ARINC-429 / 1553 interfaces Adds a multi-channel ARINC-429 or MIL-STD-1553 interface to the system. Available as a single PCI card with either or both interfaces on it, or as separate external USB interfaces. See the INTERFACES section for a comprehensive list. External channel expansion EPAD2 and CPAD2 series modules Add one or more EPAD2 series external signal conditioners to your system. Each one provides 8 thermocouple, RTD, low voltage, or low current inputs. EPAD2 modules can be daisy-chained up to 8 modules per system. CPAD2 modules are the same except with CAN BUS interface. 3 System architecture at a glance ... it´s all about DEWE-ORION and system clock D300 SERIES DEWECAM-01 MDAQ conditioners ORION A/D card DEWETRON Signal conditioning Sensor Analog Inputs Sensor supply CAN Counter Inputs Digital Inputs Digital Outputs DEWE-CLOCK ext. Clock int. Clock ARINC 429 data 1553 data PCM data e.g., sensors that output via serial bus RS232 e.g., GPS position sensors, webcams, etc. USB e.g., webcams, MiniDV cameras Custom Sensor Supply 4 e.g., data from other systems Firewire CHASSIS CPU/ RAM SOFTWARE DS-7 or LabVIEW Software sync of various PC bus interfaces (USB, ethernet, firewire, RS232...) External Time Source INDUSTRIAL-PC Ethernet www.de wame ric a .com/ D300 Counter input features DEWETRON has advanced the stateof-the-art in counter/encoder inputs in our data acquisition systems, improving yet again our ORION-counters. ADC-clock Counter input The key advancement is that our counters are PHASE SYNCHRONIZED. Referring to the diagram, you can see that a standard counter is always a sample behind. With software interpolation you can get closer, but only with DEWETRON’s advanced time shifting technology are both the phase and amplitude fully corrected! Ideal counting ORION-counter Software interpolation Standard counter DEWETRON RPM-Measurement Encoder D300 SERIES Tacho Gearthooth, CDM Gearthooth, TRG, CDM and TRG Gearthooth with missing teeth Gearthooth with double teeth Length-measurement Linear encoder Linear pulse sensor Event Counting Basic counting Gated counting Up/down counting Waveform Timing Period frequency Two pulse edge separation Period, pulse width, frequency, duty cycle 5 MDAQ Series Amplifiers Multi channel D300 SERIES Small form factor for high channel density Cost effective DEWETRON High bandwidth up to 300 kHz SUB Modules for MDAQ-BASE-x Module MDAQ-SUB-STG-D Connector: DB-9 # CH Input type 8 V MDAQ-SUB-BRIDGE-D Connector: DB-9 8 V MDAQ-SUB-V-200-D Connector: DB-9 Bandwidth (BW), Excitation Highpass filters (HP) ■ BW: 30 kHz 0 to 12 VDC ■ BW: 30 kHz HP: 0.16 Hz +15 VDC and 0 to 12 VDC ■ BW: 300 kHz ±15 VDC and 0 to 12 VDC - BW: 300 kHz - ■ BW: 300 kHz HP: 3.4 Hz 4 / 8 mA ■ BW: 300 kHz HP: 0.16 Hz 4 / 8 mA ■ BW: 300 kHz HP: 0.16 Hz, 3.4 Hz 4 / 8 mA ■ BW: 300 kHz HP: 0.16 Hz, 3.4 Hz 4 / 8 mA 15 ranges from ±2.5 mV to ±10 V 7 ranges from ±0.25 mV to ±10 V 6 ranges from ±10 to ±200 V full range of TC type -200 °C to 1000 °C and 0 to 6.5 kOhm 14 ranges from ±0.5 to 1000 mV/V (@ 5 VDC excitation 15 ranges from ±2.5 mV to ±10 V 7 ranges from ±0.25 mV to ±10 V 6 ranges from ±10 to ±200 V full range of TC type -200 °C to 1000 °C and 0 to 6.5 kOhm * Voltage up to ±200 V: * ICP, via MSI-V-ACC: * Pt100, Pt200, Pt500, Pt1000, Pt2000 and resistance via MSI-V-RTD: Note: for safety reasons, max. 120 V DC or 50 V AC 13 ranges from ±0.125 to ±200 V 7 ranges from ±0.25 mV to ±10 V -200 °C to 1000 °C and 0 to 6.5 kOhm 8 * Voltage up to ±200 V: 13 ranges from ±0.125 to ±200 V are allowed at this connector Note: for safety reasons, max. 120 V DC or 50 V AC are allowed at this connector V MDAQ-SUB-ACC-BNC Connector: BNC * Strain-gage (Full-, and half bridge) for strain gage sensors: * Voltage up to ±10 V: * ICP, via MSI-BR-ACC: * Voltage up to 200 V via MSI-BR-V-200: * Thermocouple via MSI-BR-TH-x: * Pt100, Pt200, Pt500, Pt1000, Pt2000 and resistance via MSI-BR-RTD: TEDS 14 ranges from ±0.5 to 1000 mV/V (@ 5 VDC excitation 8 V MDAQ-SUB-V-200-BNC Connector: BNC * Strain-gage (Full-, half and quarterbridge, incl. shunt calibration) for strain gage application: * Voltage up to ±10 V: * ICP via MSI-BR-ACC: * Voltage up to 200 V via MSI-BR-V-200: * Thermocouple via MSI-BR-TH-x: * Pt100, Pt200, Pt500, Pt1000, Pt2000 and resistance via MSI-BR-RTD: Input ranges 8 * ICP® or voltage up to ±10 V: 8 ranges from ±125 mV to ±10 V Single-ended or differential input and one highpass filter 3.4 Hz highpass filter for noise and shock response measurement MDAQ-SUB-ACC-BNC-S1 0,16 Hz for structural and modal analysis, human body vibration measurement (rest same as MDAQ-SUB-ACC-BNC) MDAQ-SUB-ACC-A-BNC Connector: BNC 8 * ICP® or voltage up to ±10 V: 8 ranges from ±125 mV to ±10 V Single-ended input and two HP filters 0.16 Hz for structural and modal analysis, human body vibration measurement 3.4 Hz for noise and shock response measurement MDAQ-SUB-ACC-A-MD Connector: Microdot 8 * ICP® or voltage up to ±10 V: 8 ranges from ±125 mV to ±10 V Single-ended input, two HP filters and sensor failure detection 0.16 Hz for structural and modal analysis, human body vibration measurement 3.4 Hz for noise and shock response measurement Option: test signal input for all channels 6 www.de wame ric a .com/ D300 # CH 16 Filter characteristics Butterworth Cut-off frequencies 100 Hz, 1, 10, 30, 100 kHz, Bypass DEWETRON Filter modules for MDAQ Module MDAQ-AAF4-5-BU Order th 4 Note: not possible in all system configurations. Please contact factory for details. nd 16 Butterworth 30, 100, 300 Hz, 1, 10 kHz, Bypass 2 MDAQ-FILT-5-BU-S1 16 Butterworth 100 Hz, 1, 10, 30, 100 kHz, Bypass 2 MDAQ-FILT-5-BE 16 Bessel 30, 100, 300 Hz, 1, 10 kHz, Bypass 2 D300 SERIES MDAQ-FILT-5-BU nd nd Modular smart interfaces to connect various sensors MSI interfaces MSI-BR-V-200 Differential voltage adapter, for voltages up to +/-200V. BNC connector. TEDS for automatic MSI indentification. MSI-BR-RTD Pt100, Pt200, Pt500, Pt1000, and Pt2000 adapter, for RTD sensors. 5-pin BINDER 710 series input connector. RTD power is provided. 2, 3, and 4 wire connection methods supported. TEDS for automatic MSI indentification. MSI-BR-ACC Isotron / IEPE (constant current) conditioner for IEPE accelerometers and microphones. Excitation current 4 mA at 21 VDC, 1.5 Hz high-pass filter, BNC connector. TEDS for automatic MSI indentification. MSI-BR-CHA-50 Adapter for dynamic charge sensors, range up to 50000 pC, AC coupled with 0.07 Hz, max. 100 kHz bandwidth (or limited to the max. bandwidth of the input that it is plugged into). BNC connector. TEDS for automatic MSI indentification. MSI-BR-TH-K Thermocouple adapter, type K, high accuracy cold junction reference built-in. 1 m long thermocouple cable with Mini TC connector. Isolated thermocouple sensors highly recommended for low-noise performance. TEDS for automatic MSI indentification. MSI-BR-TH-J Same as MSI-BR-TH-K except for type J sensors. MSI-BR-TH-T Same as MSI-BR-TH-K except for type T sensors. 7 D300 SERIES DEWETRON “D SERIES” INSTRUMENTS Our “D series” instruments combine data acquisition excelence with an affordable price point. Choose from among these basic models: D3PC - Smallest mainframe system, capable of 8 x IEPE /low voltage inputs DEWETRON D310 - Smallest "all in one" D series instrument, with optional display and battery backup D410 - Twice to number of possible channels as the D310, but not twice as big! D510 - Benchtop and Rackmounting "convertible" unit, capable of up to 96 fast channels D300 series 8 or 16 channels Ultra-portable 15" touchscreen (optional) 8 to 32 channels 10" touchscreen DC powered Attachable UPS option MDAQ series conditioners or ±10V inputs DAQ/HSI or MDAQ conditioners Made in USA Made in USA D410 series D510 series 16 to 32 channels Touchscreen display Convenient form factor DAQ/HSI or MDAQ conditioners 16 to 128 channels DAQ or MDAQ conditioners Benchtop or rackmounting conversion within 5 minutes Made in USA Service with a Smile! When you build something, you have to support it. If it’s an instrument, then you also need to be able to calibrate it according to NIST and ANSI Z540 standards. This is exactly what we can do for you, both in America and in Europe, using our modern Fluke Met/CAL® automated calibration procedures. We have comprehensive service and support facilities around the globe, ready to support our customers, which are increasingly global in nature. We stand behind our products, which means that we stand behind you. If you additionally require ISO/IEC 17025 certified calibration we can provide that, too. We are proud of our products, and we are ready, willing, and able to support them 100%, to ensure your satisfaction and continued patronage. Won’t you give us a try, and find out for yourself about the Dewetron difference? DEWETRON, INC. • 10 High Street, Ste K • Wakefield•RI•02879•USA Tel (+1) 401-284-3750 • Fax (+1) 401-284-3755 • [email protected] Printing version 8/15/2014 8 www.de wame ric a .com/ D300 All trademarks are acknowledged to be the property of their owners. Specification subject to change without notice. © 2014 DEWETRON, INC D310 series
Similar documents
DEWETRON DEWE-3050 features removable
to life on easy setup and display screens. You can even tailor your own screens any way that you like, moving the elements around and sizing them according to your tastes. Record continuously to di...
More informationDEWETRON D310 brochure
At the time of ordering you can choose a 15” touchscreen display to be added to the top cover (or plug in whatever display you like). A battery/UPS option is also available, which
More information