recording requested by
Transcription
recording requested by
RECORDING REQUESTED BY: FIDELITY NATIONAL TITLE CO. WHEN RECORDED RETURN TO: CITYVIEW 616 EAST CARSON, LLC 2800 28TH STREET, SUITE 206 SANTA MONICA, CA 90405 Attn: STEPHEN ROBERTS CONDOMINIUM PLAN TRACT NO. 71533 VEO TOWNHOMES (PHASE 2) 34709.002-1155444v2 CONDOMINIUM PLAN TRACT NO. 71533 VEO TOWNHOMES (PHASE 2) A CONDOMINIUM PLAN FOR LOT 3 OF TRACT MAP NO. 71533, RECORDED IN BOOK 1380, PAGES 12 THROUGH 15, INCLUSIVE, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA IN THE CITY OF CARSON, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA CERTIFICATE [CALIFORNIA CIVIL CODE SECTION 4285, et seq.] OWNER’S STATEMENT WE, THE UNDERSIGNED, HEREBY CERTIFY THAT WE ARE THE OWNERS OF THE REAL PROPERTY INCLUDED WITHIN THIS CONDOMINIUM PROJECT, AND THE RECORD HOLDERS OF SECURITY INTERESTS THEREIN; THAT WE ARE THE ONLY PERSONS WHOSE CONSENT IS NECESSARY TO PASS CLEAR TITLE TO SAID REAL PROPERTY, AND WE DO HEREBY CONSENT TO THE PREPARATION AND RECORDATION OF THIS CONDOMINIUM PLAN PURSUANT TO THE PROVISIONS OF SECTION 4285, et seq. OF THE CALIFORNIA CIVIL CODE. CITYVIEW 616 EAST CARSON, LLC, a Delaware limited liability company By: Name: Title: 1 CONDOMINIUM PLAN FOR VEO TOWNHOMES (PHASE 2) NOTARY ACKNOWLEDGMENT STATE OF CALIFORNIA ) ) ) COUNTY OF LOS ANGELES On ____________________, before me, ____________________________, a Notary Public, personally appeared _______________________________, who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument, and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Notary Public 2 CONDOMINIUM PLAN FOR VEO TOWNHOMES (PHASE 2) BENEFICIARY WELLS FARGO BANK, NATIONAL ASSOCIATION, as Beneficiary under a Deed of Trust recorded July 28, 2014, as Instrument No. 2014-0778058 of Official Records, Los Angeles County. BY: NAME: TITLE: MARK R. LOEWEN SENIOR VICE PRESIDENT NOTARY ACKNOWLEDGMENT STATE OF CALIFORNIA ) ) ) COUNTY OF LOS ANGELES On ____________________, before me, ____________________________, a Notary Public, personally appeared _______________________________, who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument, and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Notary Public 3 CONDOMINIUM PLAN FOR VEO TOWNHOMES (PHASE 2) SURVEYOR’S STATEMENT I HEREBY STATE THAT I AM A LICENSED LAND SURVEYOR OF THE STATE OF CALIFORNIA; THAT THIS CONDOMINIUM PLAN CONSISTING OF SIXTEEN (16) SHEETS, WAS PREPARED UNDER MY DIRECTION; THAT SUBJECT TO ALL OF THE NOTES AND DEFINITIONS HEREIN, THIS CONDOMINIUM PLAN SETS FORTH THE BOUNDARIES OF THE LAND AFFECTED BY THIS CONDOMINIUM PLAN AND THE LOCATION OF THE UNITS AND COMMON AREA WITHIN THE PROJECT; AND THAT SAID PLAN CONFORMS SUBSTANTIALLY TO THE AIRSPACE BOUNDARIES OF THIS CONDOMINIUM PROJECT. DATED: BY: NAME: LICENSE NO: EXPIRATION DATE: 4 CONDOMINIUM PLAN FOR LOT 3 OF TRACT NO. 71533 GENERAL NOTES AND DEFINITIONS: 1. “PROPERTY” SHALL MEAN AND REFER TO LOT 3 OF TRACT NO. 71533 IN THE CITY OF CARSON, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, AS SHOWN ON A SUBDIVISION MAP FILED ON SEPTEMBER 25, 2014, IN BOOK 1380 AT PAGES 12 TO 15, INCLUSIVE, OF MAPS, IN THE OFFICIAL RECORDS OF LOS ANGELES COUNTY. 2. “COMMON AREA” SHALL MEAN ALL THE REAL PROPERTY AND IMPROVEMENTS WITHIN THE PROPERTY, EXCLUDING THE UNITS AND THE MASTER ASSOCIATION PROPERTY THEREIN. THE COMMON AREA IS COMPRISED OF ALL PORTIONS OF THE CONDOMINIUM BUILDING, EXCLUDING THE UNITS THEREIN. 3. “CONDOMINIUM BUILDING” SHALL MEAN AND REFER TO THE BUILDING CONTAINING THE CONDOMINIUM UNITS. 4. “MASTER ASSOCIATION PROPERTY” SHALL MEAN ALL THE REAL PROPERTY AND IMPROVEMENTS WITHIN THE PROPERTY, EXCLUDING THE UNITS AND THE COMMON AREA. THE MASTER ASSOCIATION PROPERTY INCLUDES ALL IMPROVEMENTS WITHIN THE PROPERTY LOCATED OUTSIDE OF THE CONDOMINIUM BUILDING. 5. “CONDOMINIUM” SHALL MEAN AN ESTATE IN REAL PROPERTY AS DEFINED IN CALIFORNIA CIVIL CODE SECTION 4125, AND SHALL CONSIST OF AN UNDIVIDED FRACTIONAL FEE SIMPLE OWNERSHIP INTEREST IN THE COMMON AREA, TOGETHER WITH A SEPARATE OWNERSHIP INTEREST IN FEE IN A UNIT AND ALL EASEMENTS APPURTENANT THERETO. THE FRACTIONAL UNDIVIDED FEE SIMPLE INTEREST APPURTENANT TO EACH UNIT IN THE PROPERTY SHALL BE A FRACTION HAVING ONE (1) AS ITS NUMERATOR AND THE TOTAL NUMBER OF UNITS IN THE PROPERTY AS ITS DENOMINATOR AND SHALL BE HELD BY OWNERS IN THAT PROPERTY AS TENANTS IN COMMON. 6. “CONDOMINIUM PLAN” SHALL MEAN AND REFER TO THIS PLAN PREPARED IN ACCORDANCE WITH THE PROVISIONS OF SECTION 4285 OF THE CALIFORNIA CIVIL CODE. 7. “DECLARATION” SHALL MEAN AND REFER TO THAT CERTAIN “DECLARATION OF COVENANTS, CONDITIONS, AND RESTRICTIONS, AND RESERVATION OF EASEMENTS FOR VEO TOWNHOMES, AND ANY SUPPLEMENTAL DECLARATION RECORDED PURSUANT TO THE DECLARATION, WHICH ARE RECORDED AGAINST THE PROPERTY, AS MAY BE AMENDED AND/OR RESTATED FROM TIME TO TIME. IN THE EVENT OF ANY CONFLICT BETWEEN THE 34709.002-1155485v2 1 DECLARATION AND THIS CONDOMINIUM PLAN, THE DECLARATION SHALL CONTROL. ALL DEFINED TERMS USED IN THIS CONDOMINIUM PLAN, AND NOT OTHERWISE DEFINED HEREIN, SHALL HAVE THE MEANING PRESCRIBED FOR THAT TERM IN THE DECLARATION. 8. “IMPROVEMENTS” SHALL MEAN AND REFER TO ALL STRUCTURES AND APPURTENANCES THERETO OF EVERY KIND, AS MORE FULLY SET FORTH IN THE DECLARATION. 9. “UNIT” OR “SEPARATE INTEREST” SHALL MEAN A SEPARATE INTEREST IN SPACE AS DEFINED IN SECTION 4125(b) OF THE CALIFORNIA CIVIL CODE. EACH UNIT OR SEPARATE INTEREST SHALL BE A SEPARATE FREE-HOLD ESTATE, AS SEPARATELY SHOWN, NUMBERED AND DESIGNATED HEREIN, CONSISTING OF A RESIDENTIAL ELEMENT, A GARAGE ELEMENT, AN ENTRY ELEMENT, AND A PATIO ELEMENT. IN INTERPRETING DEEDS, DECLARATIONS AND PLANS, THE EXISTING PHYSICAL BOUNDARIES OF THE UNIT, OR OF A UNIT CONSTRUCTED OR RECONSTRUCTED IN SUBSTANTIAL ACCORDANCE WITH THE PLAN AS SHOWN HEREIN AND THE ORIGINAL PLANS THEREOF, IF SUCH PLANS ARE AVAILABLE, SHALL BE CONCLUSIVELY PRESUMED TO BE ITS BOUNDARIES, RATHER THAN THE DESCRIPTION EXPRESSED HEREIN, IN THE DEED OR DECLARATION, REGARDLESS OF SETTLING OR LATERAL MOVEMENT OF THE BUILDING AND REGARDLESS OF MINOR VARIANCES BETWEEN BOUNDARIES AS SHOWN HEREIN OR DEFINED IN THE DEED OR DECLARATION, AND THE BOUNDARIES OF A BUILDING AS CONSTRUCTED OR RECONSTRUCTED. WHENEVER REFERENCE IS MADE TO A UNIT, SUCH REFERENCE IS MADE TO THE UNIT AS A WHOLE, INCLUDING ITS RESIDENTIAL ELEMENT, GARAGE ELEMENT, PATIO ELEMENT, AND ENTRY ELEMENT (IF APPLICABLE), HAVING THE IDENTICAL NUMBER DESIGNATION AS THE UNIT. (A) RESIDENTIAL ELEMENT. EACH RESIDENTIAL ELEMENT IS IDENTIFIED HEREIN BY THE LETTER “R” AND ITS RESPECTIVE UNIT NUMBER, AND IS AN AIRSPACE BOUNDED BY AND CONTAINED WITHIN THE EXTERIOR SURFACES OF THE PERIMETER WALLS, WINDOWS AND DOORS, THE VERTICAL PLANES AT THE CENTER OF THE DEMISING WALLS BETWEEN EACH UNIT, AND THE INTERIOR UNFINISHED SURFACES OF THE FLOORS AND CEILINGS THEREOF. THE LOWER AND UPPER LIMITS OF EACH LEVEL OF THE RESIDENTIAL AIRSPACE ELEMENT ARE HORIZONTAL OR SLOPED PLANES, THE ELEVATIONS OF WHICH ARE INDICATED IN THE ELEVATIONS SET FORTH HEREIN. THE LATERAL BOUNDARIES OF EACH LEVEL OF THE RESIDENTIAL AIRSPACE ELEMENT ARE VERTICAL PLANES AT THE LIMITS OF THE HORIZONTAL DIMENSIONS SHOWN HEREIN FOR EACH RESIDENTIAL ELEMENT. EACH UNIT INCLUDES BOTH THE PORTION OF THE CONDOMINIUM BUILDING SO DESCRIBED AND THE AIRSPACE SO ENCOMPASSED, THE FORCED AIR HEATING UNIT, THE AIR CONDITIONING COMPRESSOR, IF ANY, DUCTS AND FLUES WHICH EXCLUSIVELY SERVE THE UNIT, THE HOT WATER HEATER OF SAID UNIT, ALL SEWER, DRAINAGE AND PLUMBING LINES WHICH 34709.002-1155485v2 2 EXCLUSIVELY SERVE THE UNIT, ALL WIRES, CONDUITS AND UTILITIES WHICH EXCLUSIVELY SERVE THE UNIT, AND ALL BUILT-IN APPLIANCES AND FIXTURES. HOWEVER, THE FOLLOWING ARE NOT A PART OF THE UNIT: PERIMETER WALLS, UNFINISHED DEMISING WALLS, BEARING WALLS, COLUMNS, BEAMS, UNFINISHED FLOORS AND CEILINGS, ROOFS, SLABS, FOUNDATIONS, LANDINGS, EXTERIOR LIGHTING AND OTHER UTILITY INSTALLATIONS WHEREVER LOCATED (EXCEPT ALL UTILITY INSTALLATIONS AND/OR OUTLETS THEREOF WHICH EXCLUSIVELY SERVE THE UNIT). THE EXISTING PHYSICAL BOUNDARIES OF THE UNIT OR A UNIT CONSTRUCTED OR RECONSTRUCTED IN SUBSTANTIAL ACCORDANCE WITH THE PLANS SHOWN HEREIN AND THE ORIGINAL PLANS THEREOF, IF SUCH PLANS ARE AVAILABLE, SHALL BE CONCLUSIVELY PRESUMED TO BE ITS BOUNDARIES, RATHER THAN THE DESCRIPTION EXPRESSED HEREIN, IN THE DEED OR DECLARATION, REGARDLESS OF SETTLING OR LATERAL MOVEMENT OF THE BUILDING AND REGARDLESS OF MINOR VARIANCE BETWEEN BOUNDARIES, AS SHOWN HEREIN, OR DEFINED IN THE DEED AND DECLARATION, AND THE BOUNDARIES OF A BUILDING AS CONSTRUCTED OR RECONSTRUCTED. (B) GARAGE ELEMENT. THE GARAGE ELEMENT IS IDENTIFIED HEREIN BY THE LETTER “G” AND ITS RESPECTIVE CONDOMINIUM UNIT NUMBER, AND IS AN AIRSPACE BOUNDED BY AND CONTAINED WITHIN THE INTERIOR UNFINISHED SURFACES OF THE PERIMETER WALLS, FLOORS, CEILINGS AND GARAGE DOOR OF SAID ELEMENT. THE LOWER AND UPPER LIMITS OF EACH GARAGE ELEMENT ARE HORIZONTAL OR SLOPED PLANES, THE ELEVATIONS OF WHICH ARE INDICATED IN THE SCHEDULE OF VERTICAL ELEVATIONS SET FORTH HEREIN. THE LATERAL BOUNDARIES OF EACH GARAGE AIRSPACE ELEMENT ARE VERTICAL PLANES AT THE LIMITS OF THE HORIZONTAL DIMENSIONS SHOWN HEREIN FOR EACH GARAGE ELEMENT. (C) PATIO ELEMENT. THE PATIO ELEMENT IDENTIFIED HEREIN BY THE LETTER “P” AND ITS RESPECTIVE UNIT NUMBER, AND IS AN AIRSPACE BOUNDED BY AND CONTAINED WITHIN THE EXTERIOR FINISHED SURFACES OF THE CONDOMINIUM BUILDING, AND THE INTERIOR UNFINISHED SURFACES OF THE PERIMETER WALLS, FENCE, OR RAILINGS ENCLOSING SUCH PATIO. THE LOWER AND UPPER LIMITS OF EACH PATIO ELEMENT ARE HORIZONTAL PLANES, THE ELEVATIONS OF WHICH ARE INDICATED IN THE SCHEDULE OF ELEVATIONS SET FORTH HEREIN. THE LATERAL BOUNDARIES OF EACH PATIO ELEMENT SHALL BE AS CONSTRUCTED, BEING THE EXTERIOR FINISHED SURFACES OF ANY EXTERIOR WALLS, WINDOWS OR DOORS OF ITS APPURTENANT RESIDENTIAL ELEMENT AND THE INTERIOR UNFINISHED SURFACES OF ANY WALL, FENCE OR RAILING THEREBY ENCLOSING SAID PATIO ELEMENT, AS MORE PARTICULARLY SHOWN AND DESCRIBED HEREIN. (C) ENTRY ELEMENT. THE ENTRY ELEMENT IDENTIFIED HEREIN BY THE LETTER “E” AND ITS RESPECTIVE UNIT NUMBER, AND IS AN AIRSPACE BOUNDED BY AND CONTAINED WITHIN THE BOUNDARIES SHOWN HEREIN. THE LOWER AND UPPER LIMITS OF EACH ENTRY ELEMENT ARE HORIZONTAL PLANES, 34709.002-1155485v2 3 THE ELEVATIONS OF WHICH ARE INDICATED IN THE SCHEDULE OF ELEVATIONS SET FORTH HEREIN. THE LATERAL BOUNDARIES OF EACH ENTRY ELEMENT SHALL BE AS CONSTRUCTED, BEING THE ENTRY AREA LEADING TO ITS APPURTENANT RESIDENTIAL ELEMENT. 10. PRESUMPTION OF BOUNDARIES. IN INTERPRETING THIS CONDOMINIUM PLAN, THE DECLARATION AND ANY INSTRUMENTS OF CONVEYANCE, THE EXISTING PHYSICAL BOUNDARIES OF THE UNIT, OR OF A UNIT RECONSTRUCTED IN SUBSTANTIAL ACCORDANCE WITH THIS CONDOMINIUM PLAN, SHALL BE CONCLUSIVELY PRESUMED TO BE ITS BOUNDARIES, RATHER THAN THE METES AND BOUNDS (OR OTHER DESCRIPTION) EXPRESSED IN THIS CONDOMINIUM PLAN, THE DECLARATION OR ANY INSTRUMENT OF CONVEYANCE, REGARDLESS OF SETTLING OR LATERAL MOVEMENT AND REGARDLESS OF MINOR VARIANCES BETWEEN THE BOUNDARIES SHOWN HEREIN, IN THE DECLARATION AND/OR IN ANY INSTRUMENT OF CONVEYANCE, AND THE ACTUAL BOUNDARIES OF THE UNIT. 11. CONDOMINIUM NUMBERING. THE INDIVIDUAL CONDOMINIUM UNITS ARE NUMBERED 764, 766, 768, 770, 772, 774, 776, 778, 780, AND 782 AS SHOWN HEREIN. 12. INTERSECTION OF LINES AND TIES. ALL AIRSPACE BOUNDARY LINES AND TIES INTERSECT EITHER AT RIGHT ANGLES OR AT FORTY-FIVE (45) DEGREE ANGLES, UNLESS OTHERWISE INDICATED. TIE DISTANCES ARE TO THE EXTERIOR FACE OF THE FOUNDATION. 13. UNIT DIMENSIONS. THIS CONDOMINIUM PLAN AND THE DIMENSIONS SHOWN HEREIN ARE INTENDED TO CONFORM TO CALIFORNIA CIVIL CODE SECTION 4285, WHICH REQUIRES, IN PART, WITH RESPECT TO THE LAND AND REAL PROPERTY DESCRIBED IN THE ABOVE REFERENCED PROPERTY, THE INCLUSION HEREIN OF DIAGRAMMATIC FLOOR PLANS OF THE BUILDING TO BE BUILT THEREON IN SUFFICIENT DETAIL TO IDENTIFY EACH UNIT, ITS RELATIVE LOCATION AND APPROXIMATE DIMENSIONS. DIMENSIONS SHOWN HEREIN ARE FOR DIAGRAMMATIC PURPOSES AND ARE NOT INTENDED TO BE SUFFICIENTLY ACCURATE ENOUGH TO USE FOR COMPUTATION OF FLOOR AREA OR AIR SPACE VOLUME ENCOMPASSED IN ALL OR ANY OF THE UNITS. THIS CONDOMINIUM PLAN IS PREPARED FOR DIAGRAMMATIC PURPOSES AND IS NOT INTENDED TO BE USED FOR SALES PURPOSES TO DETERMINE SQUARE FOOTAGE. THE DIAGRAMMATIC FLOOR PLANS CONTAINED HEREIN INTENTIONALLY OMIT INFORMATION WITH RESPECT TO THE INTERNAL PARTITIONING WITHIN THE UNITS. LIKEWISE, SUCH DETAILS AS PROTRUSIONS OF VENTS, DUCTS, BEAM COLUMNS, WINDOW CASINGS AND OTHER SUCH FEATURES INTO THE AIRSPACE ENCOMPASSED BY THE UNITS AS SHOWN ARE NOT INTENDED TO BE REFLECTED IN THIS CONDOMINIUM PLAN. 14. LATERAL DIMENSIONS. THE LATERAL DIMENSIONS OF THE UNITS ARE AS SET FORTH HEREIN. 34709.002-1155485v2 4 15. VERTICAL DIMENSIONS. THE ELEVATIONS BOUNDARIES OF THE UNITS ARE AS SHOWN HEREIN. OF THE VERTICAL 16. BASIS OF BEARINGS. N89°40’10” E OF THE NORTHERLY LINE OF CARSON STREET AS SHOWN ON TRACT NO. 2982 IN BOOK 35, PAGE 31, OF MAPS, RECORDS OF LOS ANGELES COUNTY. 17. APPLICATIONS OF DEFINITIONS. VARIOUS WORDS AND PHRASES USED HEREIN ARE DEFINED IN THE DECLARATION REFERENCED ABOVE, AND UNLESS THE CONTEXT HEREIN SHALL OTHERWISE INDICATE, SUCH WORDS AND PHRASES SHALL HAVE THE SAME MEANING HEREIN AS IS ASCRIBED TO THEM IN THE DECLARATION. 34709.002-1155485v2 5 SHEET 1 OF 15 CONDOMINIUM PLAN # LOT NO. TRACT NO. 71533 BOUNDARY AND KEY MAP PHASE 2 LOT 3 SEE SHEETS # CARSON STREET (PUBLIC STREET) N 89^13’54" E 37.00 C 7 580.17’ 11.50 RAD. N 90^00’00" E 176.89’ 677.65’ 11.50 RAD. N 90^00’00" E VI A VERDE 1 C N89^40’10"E COLORADO CIRCLE 3 N00^14’09"W NOT A PART NOT A PART COLORADO CI RCLE COLORADO CI RCLE N00^14’00"W 2 COLORADO CIRCLE N89^42’48"E 317.60’ N00^14’04"W 66.00’ N00^14’00"W 66.00’ N89^42’48"E 67.50’ N89^42’48"E 330.10’ CURVES DELTA RADIUS LENGTH TANGENT C1 90^19’50" 13.00 20.50 13.08 C7 89^40’10" 13.00 20.35 12.93 CONDOMINIUM PLAN SHEET 2 OF 15 LOT NO. # SEE SHEETS # TRACT NO. 71533 LOT 3 PHASE 2 GROUND FLOOR UNITS 774 (REVERSED), 776 (REVERSED), 778, 780, 782, 764, 766, 768, 770 (REVERSED), 772 (REVERSED) MASTER ASSOCIATION PROPERTY COLORADO CIRCLE DRIVE AND FIRE LANE) 26.0’ R782 UNI T THB3 FF=26.97 9-11 3 R772 9-11 UNI T THB3R FF=26.97 6-8 MA R770 121.64’ 13’ MA 21.0’ R768 12-13 R766 13’ 6-8 UNI T THB1 FF=26.97 12-13 UNI T THB4 FF=26.97 UNI T THB1 FF=26.97 UNI T THB3 FF=26.97 6-8 15.5’ R780 UNI T THB1R FF=26.97 UNI T THB1R FF=26.97 R774 UNI T THB3R FF=26.97 26.0’ 5.3’ N 00^00’00" W 21.23 46.12’ MA A 8.3’ 9-11 R764 117.39’ 8.5’ 9-11 6-8 111.51’ R778 UNI T THB4 FF=26.97 R776 10.1’ N00^00’ 00"W COLORADO CI RCLE ( PRI VATE DRI VE AND FI RE LANE) 136.63’ 42’ 23.5’ 15.5’ (PRIVATE D=90^00’00" R=14.50 L=22.78 N90^00’00"W 8 NOTE: A PRIVATE DRIVEWAY AND SEWER EASEMENT 35’ N MA CONDOMINIUM PLAN SHEET 3 OF 15 TRACT NO. 71533 TYPICAL BUILDING LAYOUT FIRST FLOOR RESIDENTIAL UNITS 764, 766, 768, 770 (REVERSED), 772 (REVERSED) 774 (REVERSED), 776 (REVERSED), 778, 780, 782 P R782/ P R764 E R782/ E R764 UTILITY ROOM THB-3 R782/ R764 E R780/ E R766 9-11 THB-1 R780/ R766 6-8 R768/ R778 THB-4 P R768/ P R778 12-13 R776 (REVERSED)/ R770 (REVERSED) R774 (REVERSED)/ R772 (REVERSED) E R776/ E R770 THB-1R 6-8 THB-3R 9-11 P R774/ P R772 UTILITY E R774/ E R772 ROOM B-B SHEET # PATIO P ENTRANCE E SEE SHEETS # GARAGE G CONDOMINIUM PLAN SHEET 4 OF 15 TRACT NO. 71533 TYPICAL BUILDING LAYOUT SECOND FLOOR RESIDENTIAL UNITS 764, 766, 768, 770 (REVERSED), 772 (REVERSED) 774 (REVERSED), 776 (REVERSED), 778, 780, 782 B-B SHEET # PATIO P ENTRANCE E SEE SHEETS GARAGE P R780/ P R766 P R782/ P R764 THB-3 THB-1 9-11 6-8 R780 R766 R782 R764 E R768/ E R778 THB-4 P R768/ P R778 R768 R778 12-13 THB-1R 6-8 R776(REVERSED)/ R774(REVERSED)/ R770(REVERSED) R772REVERSED) P R776/ P R770 P R774/ P R772 THB-3R 9-11 # G CONDOMINIUM PLAN SHEET 5 OF 15 TRACT NO. 71533 TYPICAL BUILDING LAYOUT THIRD FLOOR RESIDENTIAL UNITS 764, 766, 768, 770(REVERSED), 772(REVERSED), 774(REVERSED), 776(REVERSED), 778, 780, 782 B-B SHEET # PATIO P ENTRANCE E SEE SHEETS GARAGE P R782/P R764 P R780/P R766 PLAN RAISED CEILING THB-1 PLAN R780/R766 6-8 R782/R764 THB-3 9-11 PLAN THB-4 R768/R778 12-13 PLAN PLAN THB-1R R776(REVERSED)/ R774(REVERSED)/ THB-3R R772(REVERSED) 9-11 R770(REVERSED) 6-8 RAISED CEILING P 776/P 770 P 774/P 772 # G CONDOMINIUM PLAN SHEET 6 OF 15 TRACT NO. 71533 B-B PLAN TYPE: THB 1 RESIDENTIAL UNITS 766, 770 (REVERSED), 776 (REVERSED), 780 SHEET # PATIO P ENTRANCE E SEE SHEETS # G 8 BB 8 8 BB 8 AA AA GARAGE P THB-3 11.7’ THB-3 G THB-3 E THB-3 26.5’ THB-1 24. 2’ 16. 1’ 5.5’ 24. 2’ THB-3 41. 0’ 41. 0’ G THB-1 C-C 11.7’ 8 14.8’ 5.5’ 26.5’ 8. 2’ C-C 8 THB-1 P THB-1 26.5’ P THB-3 E THB-1 FIRST FLOOR COMMON CORNER SECOND FLOOR COMMON CORNER CONDOMINIUM PLAN SHEET 7 OF 15 TRACT NO. 71533 PLAN TYPE: THB 1 RESIDENTIAL UNITS 766, 770 (REVERSED), 776 (REVERSED), 780 B-B SHEET # PATIO P ENTRANCE E SEE SHEETS # G 8 BB 8 AA GARAGE P THB-3 P THB-3 THB-3 THB-3 26.5’ 26.5’ 5.5’ 5.5’ 24. 2’ THB-1 24. 2’ 16. 1’ 8 24. 2’ 24. 2’ C-C 18. 7’ THB-1 P THB-1 P THB-1 5.5’ 26.5’ 26.5’ 1.5’ 22.0’ COMMON CORNER THIRD FLOOR THIRD FLOOR (THB-1R) CONDOMINIUM PLAN SHEET 8 OF 15 TRACT NO. 71533 PLAN TYPE THB 1-CROSS SECTIONS RESIDENTIAL UNITS 766, 770 (REVERSED), 776 (REVERSED), 780 B-B SHEET # 9. 0’ 9. 0’ 24.2’ THIRD FLOOR PLAN THB 3 PATIO P ENTRANCE E SEE SHEETS 24.2’ # 24.2’ SECOND FLOOR 9. 0’ 9. 0’ GARAGE PLAN THB 3 24.2’ FIRST FLOOR 9. 0’ 9. 0’ 8.2’ G PLAN THB 3 PLAN THB 3 8.2’ SECTION A-A 9. 0’ 24.2’ PLAN THB 3 9. 0’ THIRD FLOOR 24.2’ SECOND FLOOR 9. 0’ 9. 0’ 24.2’ PLAN THB 3 24.2’ 9. 0’ 49.3’ SECTION B-B 5.5’ THIRD FLOOR 9. 0’ 9. 0’ 26.5’ THB-1 26.5’ SECOND FLOOR 9. 0’ 26.5’ 9. 0’ 26.5’ THB-1 5.5’ 26.5’ FIRST FLOOR 26.5’ SECTION C-C 9. 0’ 8.2’ GARAGE 9. 0’ FIRST FLOOR 49.3’ 9. 0’ 9. 0’ 8.2’ THB-3 5.5’ G CONDOMINIUM PLAN SHEET 9 OF 15 TRACT NO. 71533 PLAN TYPE: THB 3 RESIDENTIAL UNITS 764, 772 (REVERSED), 774 (REVERSED), 782 B-B SHEET # PATIO P ENTRANCE E 20.6’ 2’ 20. 8’ UTILITY 14’ ROOM G THB-1 20. 2’ 33. 8’ G THB-3 THB-3 5.8’ 14. 0’ P THB-3 7. 2’ 4. 5’ E THB-3 14.8’ THB-1 5.5’ COMMON CORNER FIRST FLOOR 11 BB 11 AA SEE SHEETS GARAGE # G CONDOMINIUM PLAN SHEET10 OF 15 TRACT NO. 71533 PLAN TYPE: THB 3 RESIDENTIAL UNITS 764, 772 (REVERSED), 774 (REVERSED), 782 B-B SHEET # PATIO P ENTRANCE E SEE SHEETS # G P THB-3 7.8’ 17. 3’ 17. 3’ RAISED CEILING 25. 1’ THB3 31.4’ THB3 13.5’ 17.9’ 31.4’ THB1 P THB-1 P THB-1 COMMON CORNER THB1 COMMON CORNER SECOND FLOOR 11 BB 13.5 7.8’ 17. 3’ 5.7’ 10.4’ 25. 1’ 9. 8’ 10.4’ 9. 8’ 13.2’ 2. 0’ 13.2’ P THB-3 11 AA 2’ BB 11 AA 11 GARAGE THIRD FLOOR CONDOMINIUM PLAN SHEET11 OF 15 TRACT NO. 71533 B-B PLAN TYPE THB 3 - CROSS SECTIONS RESIDENTIAL UNITS 764, 772 (REVERSED), 774 (REVERSED), 782 SHEET # PATIO P ENTRANCE E SEE SHEETS 2. 5’ GARAGE 17.3’ PLAN THB 1 9. 0’ 11. 5’ 9.8’ THIRD FLOOR 27.1’ 9. 0’ PLAN THB 1 9. 0’ 27.1’ SECOND FLOOR 27.1’ 9. 0’ 9. 0’ PLAN THB 1 FIRST FLOOR G PLAN THB 3 20.2’ 9. 0’ 20.8’ 20.2’ 20.8’ SECTION A-A SEE SHEETS 9 &10 FOR PLAN VIEW THIRD FLOOR 9. 0’ PLAN THB 1 9. 0’ 23.6’ 23.6’ SECOND FLOOR 25.1’ PLAN THB 1 G PLAN THB 1 SECTION B-B SEE SHEETS 9 &10 FOR PLAN VIEW 9. 0’ PLAN THB 1 9. 0’ 25.1’ # G CONDOMINIUM PLAN SHEET12 OF 15 TRACT NO. 71533 PLAN TYPE: THB4 RESIDENTIAL UNITS 768,778 B-B SHEET # PATIO P ENTRANCE E SEE SHEETS # G 13 13 BB 13 AA 13 BB 13 1.8’ 2. 5’ BB 13 AA AA GARAGE 13.7’ 22.1’ 6.6’ 22.1’ 42. 5’ 42. 5’ 37. 5’ 38. 0’ 39. 3’ 39. 3’ G THB-4 3’ 7.3’ 15.7’ 4’ P THB-4 5’ 2’ 2.4’ 2’ 2’ 4’ 5’ 13.4’ 13.4’ 2.4’ 22.1’ 2.3’ COMMON CORNER P THB-4 COMMON CORNER E THB-4 COMMON CORNER FIRST FLOOR SECOND FLOOR THIRD FLOOR CONDOMINIUM PLAN SHEET 13 OF 15 TRACT NO. 71533 B-B PLAN TYPE THB4 CROSS SECTIONS RESIDENTIAL UNITS 768,778 SHEET # PATIO P ENTRANCE E SEE SHEETS GARAGE 9. 0’ 9. 0’ 42.5’ THIRD FLOOR 42.5’ 9. 0’ 38.0’ 14. 5’ SECOND FLOOR G PLAN THB-4 9. 0’ 4. 5’ 9. 0’ 20.8’ 39.3’ SECTION A-A SEE SHEET 12 FOR PLAN VIEW 9. 0’ 9. 0’ 42.5’ THIRD FLOOR 42.5’ 9. 0’ P 9. 0’ 37.5’ SECOND FLOOR 37.5’ 7.3’ FIRST FLOOR G PLAN THB-4 39.3’ SECTION B-B SEE SHEET 12 FOR PLAN VIEW 9. 0’ P 9. 0’ 20.8’ # G CONDOMINIUM PLAN TRACT NO. 71533 PHASE 2 LOT 3 SHEET14 OF 15 CONDOMINIUM PLAN N.T.S. SHEET 15 OF 15 TRACT NO. 71533 LOT 3 PHASE 2 IN THE CITY OF CARSON, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA ELEVATIONS & AIRSPACE PLAN NOTE: THIS DIAGRAM IS INTENDED FOR ILLUSTRATIVE PURPOSES ONLY. AS BUILT CONDITIONS WILL CONTROL. MASTER ASSOCIATION PROPERTY MASTER ASSOCIATION PROPERTY ROOF COMMON AREA 9.00’ 1000’ UNIT LEVEL 3 COMMON AREA 9.00’ UNIT MASTER ASSOCIATION PROPERTY ADJACENT UNIT MASTER ASSOCIATION PROPERTY LEVEL 2 COMMON AREA 9.00’ UNIT FF GROUND LEVEL (GARAGE LEVEL/LEVEL 1) COMMON AREA TO CENTER OF EARTH MASTER ASSOCIATION PROPERTY COMMON AREA TO CENTER OF EARTH TO CENTER OF EARTH MASTER ASSOCIATION PROPERTY