Pegler Yorkshire - RIBA Product Selector

Transcription

Pegler Yorkshire - RIBA Product Selector
Pegler Yorkshire
SUPERIOR QUALITY
HEAT INTERFACE UNITS
PUTTING YOU IN CONTROL
Pegler Yorkshire
PUTTING YOU
IN CONTROL
Diverse industry expertise combined with cuttingedge technological innovation mean Pegler Yorkshire’s
Control solutions help you overcome unique
challenges and meet the highest standards in
both performance and system aesthetics.
PERFORMANCE WITH PRECISION
Pegler Yorkshire’s Control products enable you to balance precision
flow control, energy efficiency and comfort through innovative
products and systems that ensure building performance criteria are
met and the resulting installation is easy, efficient and economical
to operate.
Our comprehensive Terrier, Meibes and Ballorex product ranges
offer proven energy saving solutions, exceptional accuracy and
optimised system performance – so, whatever your project or
challenge, you can be sure you’ll always be in control.
GLOBAL EXPERIENCE, COMBINED EXPERTISE
With over 100 years of manufacturing and innovation combined
with extensive industry knowledge and worldwide market
experience, Pegler Yorkshire offers the most advanced and
complete Connect & Control systems on a global scale.
As one of Britain’s largest and most respected manufacturers and
suppliers of products for the plumbing and heating industries,
Pegler Yorkshire is confident we can provide you with all the
controls, connections and support your project requires.
For more information visit
www.pegleryorkshire.co.uk
2
CONTENTS
ENERGY EFFICIENT SOLUTIONS SUITABLE
FOR CENTRALISED BOILER PLANTS
Introduction
A comprehensive range for all applications
Service
Energy efficiency with improved SAP ratings
Pegler Yorkshire is pleased to be
associated with several influential
industry organisations:
A TOTAL SUPPORT PACKAGE FOR SPECIFIERS,
CONTRACTORS AND FACILITIES MANAGERS
Benefits
Choosing the best system for your application
Association of
Plumbing and
Heating Contractors
The Bathroom
Manufacturers
Association
The UK
Copper Board
The Chartered Institution of
Building Services Engineers
Brass
pec
4
4-5
6
7
8
9-11
PRODUCT DETAILS
Product focus
A2 RX Blu-Climate range
A2 UX Blu-Climate range
A1 RX Blu-Climate range
A1 CX Blu-Climate range
12-13
14-17
18-21
22-25
26-29
TECHNICAL GLOSSARY
30-31
DISTRICT HEATING SYSTEMS CLIMATE CONTROL
32-33
CERTIFICATION LTD
The Brass Page for
specifiers, designers,
engineers and manufacturers
British Plumbing
Employers Council
Thermostatic
Mixing Valve
Manufacturers
Association
Construction
Products
Association
The Copper
Development
Association
Scottish and Northern Ireland
Plumbing Employers
Federation
Builders Merchants
Federation
Institute of
Plumbing
The UK District
Energy Association
3
ENERGY EFFICIENT SOLUTIONS SUITABLE
FOR CENTRALISED BOILER PLANTS
The Meibes brand and German heritage is renowned for its precision engineering quality and
innovative designs that deliver unparalleled performance, efficiency and ease of installation.
Meibes Heat Interface Units (HIUs) facilitate the use of
centralised systems for space heating and domestic
hot water in multi-residential buildings. They are high
performing units, engineered with fully tested and
approved components, designed to provide optimum
performance for end users, while ensuring that they are
easy to install and maintain.
Pegler Yorkshire also holds a comprehensive range
of spares for fast delivery throughout the UK.
Meibes HIUs are pre-fabricated units linked to the
central heat source(s) via a network of three pipes –
heating flow and return and a separate potable water
feed. A zone valve in each unit, linked to a standard
timer and room thermostats, controls the space heating
for each apartment.
A patented Proportional Modulating (PM) valve
intelligently prioritises the requirement for domestic
hot water (DHW) over heating, in a similar way to a
combi boiler.
A COMPREHENSIVE RANGE
FOR ALL APPLICATIONS
The Meibes HIUs offered by Pegler Yorkshire have
been designed to meet the specific needs of the
UK market. For example, Meibes HIUs for the UK
are configured for top-entry pipework for ease of
installation in ceiling voids
The breadth of the Meibes HIU range delivers solutions
for all types of centralised heating networks serving
multi-residential accommodation, ensuring effective
control of heating and DHW in apartments and other
spaces. The design of HIUs facilitates a balanced system
that delivers consistent performance, irrespective of
variation in hot water demands or how far the units are
from the plant room.
TYPICAL APPLICATIONS
Private apartments
Local Authority accommodation
Housing Associations
Student accommodation
Nurse accommodation
Sheltered housing.
4
“Whatever the application, Meibes HIU have
the authoritative solution”
DESIGN
BUILD
Performance
Installation innovation
Pegler Yorkshire has various high performance Meibes
HIU products that are suitable when designing
apartments with multiple bathrooms. These ensure
reliable performance for individual use and against the
overall building requirements. Guidance on network
and temperature flow rates can also be provided by the
Pegler Yorkshire team.
The Meibes HIU range is part of Pegler Yorkshire
Connect & Control, which fully recognises the
importance of minimising installation costs whilst
ensuring the building performs efficiently and optimally.
Meibes HIUs were one of the first to be designed with
a first fix rail which is available to aid staged installation,
supporting the primary network set-up.
Allocating design space
No special commissioning required
Meibes HIU headline A2 RX Indirect Heating and
Domestic Hot Water units are compact in size at only
500mm wide, enabling them to be fitted into minimal
cupboard space. This also provides the option to fit
them into an appliance space. Further options are also
available for direct heating units at 650mm wide.
Meibes HIUs are designed to remove complications
and provide clarity on installation. There is no need to
have a specialist for commissioning as the standard
installation process requires a competent installer to
simply follow the specifier’s set-up parameters.
UK solution
Pegler Yorkshire is one the leading manufacturers
of commercial plumbing and heating systems. Our
expertise and experience enables contractors to
benefit significantly when it comes to project costs, and
technical and service support, by using a connect and
control system they can trust.
Pegler Yorkshire ensures that UK experience, system
design and installation and practices drive the solution
to the product, which is why the Meibes range of
HIUs is designed to meet UK needs. As a result there
is no need to compromise and adapt to HIU’s with a
European configuration.
Expertise
5
ENERGY EFFICIENT SOLUTIONS SUITABLE
FOR CENTRALISED BOILER PLANTS
SERVICE
Guarantee
Pegler Yorkshire provides ultimate engineering and
performance confidence. Down time can lead to client
frustration and experience is the key to a well-managed
building project. Meibes HIUs combine high quality
components and reliability to deliver a peace of mind
proposition which prevents expensive call backs.
Service
Pegler Yorkshire is committed to providing an after
service experience that allows peace of mind for
contractors and facility managers. A network of service
teams is available with dedicated telephone support
lines providing technical advice.
2
year
guarantee
on moving
parts
6
ENERGY EFFICIENCY WITH
IMPROVED SAP RATINGS
Centralised heating systems are becoming increasingly
popular for multi-residential properties as they offer a
number of key advantages over decentralised systems
with individual boilers in each apartment. These include:
Improved energy efficiency
11% improvement in SAP ratings
(compared to decentralised systems)
No gas installation throughout the building
Energy-saving features of Meibes HIUs
Meibes HIUs operate on a ‘no demand-no flow’ basis,
so that when there is no demand for heating or DHW
the unit effectively goes into standby. The arrangement
minimises the demand on the main network, reduces
energy consumption and ensures the apartment is
not over-heated.
The performance of the units is based on primary flow
temperatures of 65°C, enabling use with low carbon
heat sources such as heat pumps. The resulting low
return water temperatures also help to maximise
condensing when condensing boilers are used.
No flues in apartments
Ease of access to heating plant for maintenance
Simple integration of low carbon and renewable
heat sources.
To help ensure minimum heat losses from the system,
all pipework is pre-insulated to save energy and reduce
onsite insulation work. For further energy savings an
A-rated pump aligns water flows with heating demand
to minimise pump energy consumption.
7
A TOTAL SUPPORT PACKAGE FOR
SPECIFIERS, CONTRACTORS AND
FACILITIES MANAGERS
Meibes HIUs deliver key benefits for all parties in the supply chain, from initial system design
through to everyday operation and maintenance. All backed by the expertise and support of
Pegler Yorkshire.
BENEFITS FOR SPECIFIERS AND DEVELOPERS
Lower capital costs
Reduced installation time
Simpler design of heating systems
Simpler pipework systems
No hot water storage necessary
Improved energy efficiency and SAP rating
Facilitates integration of different heat sources
All distribution at low pressure and temperature
Easier to gain planning consent.
BENEFITS FOR CONTRACTORS
Ease of installation
Faster fix times
Ability to separate first and second fix
Ease of access to components
Annual servicing requirement.
BENEFITS FOR FACILITIES/PROPERTY MANAGERS
All plant in a single plant room
No need to enter apartments for routine maintenance
Reduced energy consumption
Heat metering for billing residents
Ease of renewables inclusion
Reduced carbon footprint
Reduced annual boiler servicing cost over individual boilers.
8
CHOOSING THE BEST SYSTEM FOR YOUR APPLICATION
The Meibes HIU range includes a number of different models for different applications. Use the
flow chart below to select the most appropriate model for your project.
No. of
bathrooms
Heating to be
connected to
the supply
(direct)
or
Separated
via a heat
exchanger
(indirect)?
Heating
& DHW
Direct
Heating
& DHW
DHW
requirement
for shower/
bath?
One
Two
+
Accessories
No. of
bathrooms
DHW
requirement
for shower/
bath?
Indirect
Heating
& DHW
One
Two
Radiator
Stored DHW
requirement?
Meibes
HIU
A1 RX
Instantaneous
DHW
requirement?
Heat
Exchanger
Meibes
HIU
A2 RX
Meibes
HIU
A2 RX
+
Accessories
Type of
Emitter?
Underfloor
No. of
bathrooms
DHW
requirement
for shower/
bath?
One
Two
Meibes
HIU
A2 UX
Meibes
HIU
A2 UX
+
Accessories
No. of
bathrooms
Cylinder
DHW
requirement
for shower/
bath?
One
Two
Meibes
HIU
A1 CX
+
Accessories
9
CHOOSING THE BEST SYSTEM
FOR YOUR APPLICATION
The comprehensive Meibes HIU range ensures that these units can be used with a range of
different system configurations.
INDIRECT SYSTEM – A2 RX/A2 UX
SYSTEM BENEFITS
The indirect system provides both indirect space
heating and indirect DHW. The system uses twin
heat exchange units to supply instantaneous DHW
and space heating.
The Proportional Modulating Valve operates in the
same way as a combi diverter valves. Whenever
there is a call for DHW, the PM valve diverts the
primary flow through the heat exchanger to generate
DHW, using all available energy to support the DHW
demand. Typically, this results in the heating circuit
being closed for just a few minutes, having minimal
impact on occupant comfort.
Reduces heat losses
Reduces pumped volume
around primary circuit
Removes peak load issues
CENTRAL
HEAT
GENERATOR
HEAT
INTERFACE
UNIT
Protects against variation
in flow and return rates
between apartments
(Primary heating
separate to
apartment circuit)
Separate heating circuit
Flexible temperature control
Mains water
Primary flow
Primary return
When the DHW demand has been satisfied the
primary flow reverts to the space heating system.
RADIATOR/
UNDERFLOOR
HEATING
Heating flow
Heating return
Potable water
DHW flow
DIRECT SYSTEM – A1 RX
Low maintenance
requirements.
SYSTEM BENEFITS
The direct configuration delivers the primary heating
direct to the apartment circuit, with indirect DHW.
Reduced cost
Less space required in
apartment
CENTRAL
HEAT
GENERATOR
Low maintenance
requirements.
HEAT
INTERFACE
UNIT
(Primary heating
direct to
apartment circuit)
Mains water
Primary flow
Primary return
HEAT
EMITTER
Heating flow
Heating return
Potable water
DHW flow
INDIRECT FOR CYLINDER SYSTEM –
A1 CX
When using a cylinder system the primary circuit is
separate to the secondary circuit, so that hot water
is supplied from the cylinder, ensuring hot water is
always available. The system incorporates a zone
valve which is controlled by standard controls such
as a time clock and a room thermostat to switch off
the unit when there is no demand, thereby reducing
network load.
SYSTEM BENEFITS
Simple design
DHW
CYLINDER
Heat usage metered
Hot water reserve
in apartment.
CENTRAL
HEAT
GENERATOR
HEAT
INTERFACE
UNIT
(Using a
cylinder
system)
HEAT
EMITTER
Mains water
Primary flow
Primary return
10
Differential pressure control
Heating flow
Heating return
Potable water
DHW flow
A2 RX
A1 RX
A1 CX
A2 UX
11
PRODUCT FOCUS
Primary
return
Strainer – protects
from system debris
and prolongs life
Differential Pressure
Control Valve –
improved control,
performance
and installation
Primary Cold water
flow
mains
DHW
Heating
flow
Heating
return
Strainer – protects
from system debris
and prolongs life
Pump – A-rated
pump ensures
efficient
performance
Proportional
Modulation Valve
– gives priority to
heating over DHW
Blending valve
Heat exchanger
(DHW) – provides
highly efficient
performance from
a compact unit
A2 RX HIU
12
Heat exchanger (IH)
FIX RAILS
First fix rails allow a faster installation that can be
staged to align with progress on other parts of the
project. For example, the first fix may be carried out
in the early stages, with the HIUs themselves being
installed later in the project schedule. This reduces
the risk of onsite damage to the HIUs.
The first fix rail is secured to the wall in the
appropriate position allowing all plumbing
connections to be made, pressure tested, flushed
and filled. Depending on the nature of the contract,
this may also support staged billing for work carried
out and products installed.
HEAT METERS
FEATURES
WRAS approved ball valves
Factory sealed flow/
return connections
Primary Bypass Module
Available with bypass for
easy system flushing
Fix rail supports primary
pipe work testing.
First fix Rail (also available with
Primary Bypass Module)
FEATURES
Meibes HIUs can be factory-fitted with optional
heat meters, allowing for accurate, measurement
of heat energy use in individual apartments. Use of
factory-fitted heat meters reduces onsite work and
enables optimum use of skilled labour for more
complex tasks. Factory-fitted units are pressure
tested before delivery to site.
Heat meter measures the
differential between flow
and return temperatures
Data from the heat meters can be collected
manually or via a wired or wireless network.
Pre-payment can also be incorporated.
RHI and OMS compliant
MID approved factory fitted
ultrasonic heat meters
Conforms to
EN1434-3;1997
Common Mbus output
into data extraction
10 year battery life
Permanent display
(shown in kWh).
DATA EXTRACTION
The most popular form of data extraction from
heat meters is an Mbus network connection,
which can be pre-fitted to the heat meter. The
data extraction unit sends a master signal to slave
meters, which then report on energy consumption
data. The readings can be sent via email or pulled
directly from the data logger.
Where required, heat meters can be fitted with
radio-based data extraction systems.
FEATURES
Ability to consolidate
readings from up to
400 meters
Allows data extraction to
be directly or remotely
configured
Flexible programming
allows meter readings to
be time defined
Data can be retrieved or
sent automatically via email
as CSV-file or xml-file
Available
May 2014
SD card as back-up to
prevent risk of data loss.
13
PRODUCT DETAILS
MEIBES HIU INDIRECT UNIT
A2 RX BLU-CLIMATE RANGE
14
MEIBES HIU
A2 RX BLU-CLIMATE RANGE
The A2 RX is a higher capacity version of the A1 RX, suitable for apartments with two bathrooms.
FEATURES & BENEFITS
Designed to provide instantaneous Domestic Hot
Water and Indirect Heating
Compact design – 500mm wide
Available in 15 and 19 litres per minute of DHW
HIU enables secondary heating for radiators
High specification Differential Pressure
Control Valve
Unique trickle bypass to enable unit primed
for DHW
Available with case with window for viewing
heat meter
Also available without case for fitting within an
existing cabinet
687902/687906
First fix rails and bypass option also available
Complete with WRAS approved ball valves
Top connections for easy contractor access.
A2 RX Blu-Climate HIU range options
HIU model
With box
With heat meter
Code
Meibes A2 RX Blu-Climate HIU 15 IDH & HW HM
Yes
Yes
687900
Meibes A2 RX Blu-Climate HIU 15 IDH & HW
Yes
No
687901
Meibes A2 RX Blu-Climate HIU 15 IDH & HW HM B
No
Yes
687902
Meibes A2 RX Blu-Climate HIU 15 IDH & HW B
No
No
687903
Meibes A2 RX Blu-Climate HIU 19 IDH & HW HM
Yes
Yes
687904
Meibes A2 RX Blu-Climate HIU 19 IDH & HW
Yes
No
687905
Meibes A2 RX Blu-Climate HIU 19 IDH & HW HM B
No
Yes
687906
Meibes A2 RX Blu-Climate HIU 19 IDH & HW B
No
No
687907
A2 RX Blu-Climate HIU accessory options
Accessory
Code
Meibes A2 RX Fix Rail
687550
Meibes A2 RX Fix Rail TP
687551
15
PRODUCT DETAILS
MEIBES HIU TECHNICAL
& PERFORMANCE
O
C DATA
A2 RX BLU-CLIMATE RANGE
A2 RX Blu-Climate HIU
Technical data
Type
Description
Construction
Duty (primary)
domestic hot
water mode
Duty (secondary)
domestic hot water
Duty (secondary)
heating
Pressure
Connections
Mounting
Wall mounted
Size (WxDxH, height of the case)
500 x 350 x 750mm
Heating system
2 pipe flow
Pipework
Fully insulated flexible stainless steel with brass fittings
Plates heat exchanger
Stainless steel (heat exchanger space heating fully insulated)
Casing
White powder coated sheet steel cover
Primary fluid
Low pressure hot water
Secondary fluid – heating
Low pressure hot water
Secondary fluid – domestic hot water
Potable hot water service
Heat transfer capacity
42kW
50kW
Flow rate
0.275 l/s (990 l/h)
0.282 l/s (1,014 l/h)
Minimum flow temperature primary
65ºC
65ºC
Heat transfer capacity
42kW @ 40K ΔT
50kW @ 40K ΔT
Flow rate
15 l/min (0.250 l/s)
19 l/min (0.317 l/s)
Fluid temperature in
10ºC
10ºC
Fluid temperature out
50ºC
50ºC
Blending valve
35-65ºC
35-65ºC
Capacity
20kW max. @ 20K ΔT
20kW max. @ 20K ΔT
Fluid temperature flow
60ºC @ 65ºC primary flow
60ºC @ 65ºC primary flow
Fluid temperature return
40ºC
40ºC
Maximum primary pressure
10bar
10bar
Maximum secondary pressure
3bar
3bar
Minimum supply water pressure
2bar, maximum 4bar
2bar, maximum 4bar
All external connections
¾"
¾"
Secondary circulation pump
Fittings –
primary and
secondary heating
Fittings –
secondary domestic
hot water service
16
Heat Interface Unit for indirect heating and
instantaneous domestic hot water
Wilo ‘A rated’ pump in secondary flow
Expansion vessel
8 litre fitted in secondary flow
Strainer
On primary flow and secondary return
Sensor pockets
Flow for heat meter
Heat meter
Rossweiner ‘HeatSonic’ M-Bus heat meter with permanent display
Differential Pressure Control Valve
(DPCV)
Factory set at 30kPa (maximum differential pressure 250kPa)
Primary bypass/trickle bypass
Thermostatic bypass between primary flow and return
Air vents
Manual
Controls
Not pre-fitted – externally mounted single channel time switch + roomstat
Controls
Proportional modulation controlled
Dimensions and clearances
Hydraulic layout
Primary side
Return
Flow
Secondary side
Cold water mains
Domestic hot/cold water
DHW
Flow
Return
1
3
W
2
2
8
4
3
5
16
6
10
15
7
13 14
12
M
9
P
11
Key
1 First fix Rail with connection ball valves (not illustrated)
2 Strainer
3 Provision for test points (½" connection)
4 Heat meter
5 Differential Pressure Control Valve (DPCV)
6 Proportional Modulation Valve (PMV)
7 Plate heat exchanger, DHW
8 Thermostatic blending valve
9 Drain point
10 Thermostatic circulation valve (trickle bypass)
11 Zone valve. Primary side space heating circuit
12 Plate heat exchanger. Space heating
13 Pressure gauge, secondary side
14 Over pressure relief valve, secondary side
15 Expansion vessel
16 Circulator pump, secondary side
750mm
500mm
350mm
Flow performance
100
100
90
90
80
80
15L of DHW @
70
60ºC
Primary flow degrees ºC
Primary flow degrees ºC
70
60
15L of DHW @
15L of DHW
50
50ºC
@ 45ºC
40
30
19L of DH
W
60
19L of DH
W
19L of DH
W
50
@ 60ºC
@ 50ºC
@ 45ºC
40
30
36.43kW/cold water 10ºC
46.15kW/cold water 10ºC
20
20
41.61kW/cold water 10ºC
52.70kW/cold water 10ºC
51.92kW/cold water 10ºC
10
64.76kW/cold water 10ºC
10
*The primary flow should not exceed 1,000 l/h
0
*The primary flow should not exceed 1,000 l/h
0
0
500
1000
1500
2000
Primary flow rate l/h*
2500
3000
3500
0
500
1000
1500
2000
2500
3000
3500
Primary flow rate l/h*
17
PRODUCT DETAILS
MEIBES HIU INDIRECT UNIT
A2 UX BLU-CLIMATE RANGE
18
MEIBES HIU
A2 UX BLU-CLIMATE RANGE
A2 UX models have been specifically designed for use with underfloor heating.
FEATURES & BENEFITS
Designed to provide instantaneous Domestic
Hot Water and Indirect Heating
Compact design – 500mm wide
Available in 19 litres per minute of DHW
HIU enables secondary heating for
underfloor heating
Integrated thermix module
High specification Differential Pressure
Control Valve
Available
May 2014
Unique trickle bypass to enable unit primed
for DHW
687932
Available with case with window for viewing
heat meter
Also available without case for fitting within an
existing cabinet
Complete with fix rails
Bypass option also available
Complete with WRAS approved ball valves
Top connections for easy contractor access.
A2 UX Blu-Climate HIU range options
HIU model
With box
With heat meter
Code
Meibes A2 UX Blu-Climate HIU 19 IDH & HW HM
Yes
Yes
687930
Meibes A2 UX Blu-Climate HIU 19 IDH & HW
Yes
No
687931
Meibes A2 UX Blu-Climate HIU 19 IDH & HW HM B
No
Yes
687932
Meibes A2 UX Blu-Climate HIU 19 IDH & HW B
No
No
687933
A2 UX Blu-Climate HIU accessory options
Accessory
Code
Meibes A2 RX Fix Rail
687550
Meibes A2 RX Fix Rail TP
687551
19
PRODUCT DETAILS
MEIBES HIU TECHNICAL
& PERFORMANCE
O
C DATA
A2 UX BLU-CLIMATE RANGE
A2 UX Blu-Climate HIU
Technical data
Type
Description
Construction
Duty (primary)
domestic
hot water mode
Duty
(secondary)
domestic
hot water
Duty
(secondary)
heating
Pressure
Connections
Fittings –
primary and
secondary heating
Fittings –
secondary domestic
hot water service
20
District heating station for indirect heating and
instantaneous domestic hot water
Mounting
Wall mounted
Size (WxDxH, height of the case)
500 x 350 x 750mm
Heating system
2 pipe flow
Pipework
Fully insulated flexible stainless steel with brass fittings
Plates heat exchanger
Stainless steel (heat exchanger space heating fully insulated)
Casing
White powder coated sheet steel cover
Primary fluid
Low pressure hot water
Secondary fluid – heating
Low pressure hot water
Secondary fluid – domestic hot water
Potable hot water service
Heat transfer capacity
50kW
Flow rate
0.282 l/s (1,014 l/h)
Minimum flow temperature primary
65ºC
Heat transfer capacity
50kW @ 40K ΔT
Flow rate
19 l/min (0.317 l/s)
Fluid temperature in
10ºC
Fluid temperature out
50ºC @ 65ºC primary flow temperature
Blending valve
35-65ºC
Capacity
20kW max. @ 20K ΔT
Fluid temperature flow
60ºC @ 65ºC primary flow
Fluid temperature return
Max. 40ºC (depends on UFH settings)
Maximum primary pressure
10bar
Maximum secondary pressure
3bar
Minimum supply water pressure
2bar
Maximum supply water pressure
4bar
All external connections
¾"
Secondary circulation pump
‘Thermix’ underfloor heating module with Grundfos pump
and automatic mixer 20-80ºC
Expansion vessel
12 litre fitted in secondary flow
Strainer
On primary flow and secondary return
Sensor pockets
Flow for heat meter
Test points
Binder style test points
Heat meter
Rossweiner ‘HeatSonic’ M-Bus heat meter with permanent display
Differential Pressure Control Valve
(DPCV)
Factory set at 30kPa (maximum differential pressure 250kPa)
Primary bypass/trickle bypass
Thermostatic bypass between primary flow and return
Air vents
Manual
Zone valve
Fitted with electrical actuator head,
max. differential pressure 100 kPa (kvs=1.85)
Controls
Not pre-fitted – externally mounted single channel time switch + roomstat
Controls
Proportional modulation controlled
Dimensions and clearances
Hydraulic layout
Primary side
Return
Domestic hot/cold water
Cold water
DHW
mains
Flow
Secondary side
Flow
Return
1
3
W
2
2
8
4
3
5
16
6
10
15
7
13 14
12
M
9
P
11
Key
1 First fix rail with isolating ball valves
2 Strainer
3 Provision for test points (½" connection)
4 Heat meter
5 Differential Pressure Control Valve (DPCV)
6 Proportional Modulation Valve (PMV)
7 Plate heat exchanger, DHW
8 Thermostatic blending valve
9 Drain point
10 Thermostatic circulation valve (trickle bypass)
11 Zone valve. Primary side space heating circuit
12 Plate heat exchanger. Space heating
13 Pressure gauge, secondary side
14 Over pressure relief valve, secondary side
15 Expansion vessel
16 Underfloor heating, module secondary side (inc. pump mixer)
750mm
500mm
350mm
Flow performance
100
100
90
90
80
80
15L of DHW @
70
60ºC
Primary flow degrees ºC
Primary flow degrees ºC
70
60
15L of DHW @
15L of DHW
50
50ºC
@ 45ºC
40
30
19L of DH
W
60
19L of DH
W
19L of DH
W
50
@ 60ºC
@ 50ºC
@ 45ºC
40
30
36.43kW/cold water 10ºC
46.15kW/cold water 10ºC
20
20
41.61kW/cold water 10ºC
52.70kW/cold water 10ºC
51.92kW/cold water 10ºC
10
64.76kW/cold water 10ºC
10
*The primary flow should not exceed 1,000 l/h
0
*The primary flow should not exceed 1,000 l/h
0
0
500
1000
1500
2000
Primary flow rate l/h*
2500
3000
3500
0
500
1000
1500
2000
2500
3000
3500
Primary flow rate l/h*
21
PRODUCT DETAILS
MEIBES HIU DIRECT UNIT
A1 RX BLU-CLIMATE RANGE
22
MEIBES HIU
A1 RX BLU-CLIMATE RANGE
The A1 RX unit provides direct heating and instantaneous hot water.
FEATURES & BENEFITS
Designed to provide instantaneous Domestic
Hot Water and Direct Heating
Compact design – 600mm wide
Available in 17 litres per minute of DHW
HIU enables differential pressure controlled
primary heating for radiators
Unique trickle bypass to enable unit primed
for DHW
Includes heat meter (optional)
Top connection
Also available without case for fitting within an
existing cabinet
Bottom connection
Complete with fix rails and connectors for
top connection
Complete with WRAS approved ball valves.
A1 RX Blu-Climate HIU range options
HIU model
With box
With heat meter
Code
Meibes A1 RX Blu-Climate HIU 17 DH & HW HM
Yes
Yes
687950
Meibes A1 RX Blu-Climate HIU 17 DH & HW
Yes
No
687951
Meibes A1 RX Blu-Climate HIU 17 DH & HW HM B
No
Yes
687952
Meibes A1 RX Blu-Climate HIU 17 DH & HW B
No
No
687953
A1 RX Blu-Climate HIU accessory options
Accessory
Code
Meibes A1 RX Fix Rail (for bottom connection)
687570
Meibes A1 RX Fix Rail (for top connection)
687573
Meibes A1 RX Hose Flush
687571
Meibes A1 RX Water Meter
687572
23
PRODUCT DETAILS
MEIBES HIU TECHNICAL
& PERFORMANCE
O
C DATA
A1 RX BLU-CLIMATE RANGE
A1 RX Blu-Climate HIU
Technical data
Description
Construction
Duty (primary)
domestic
hot water mode
Duty
(sanitary)
Apartment substation for direct and instantaneous domestic hot water
Wall mounted
Size (WxDxH, height of the case)
600 x 210 x 800mm
Heating system
2 pipe flow
Pipework
Fully insulated flexible stainless steel with brass fittings
Plate heat exchanger
Stainless steel heat exchanger for domestic hot water
(non-insulated for fast cool down/insulated if optional sanitary circulation)
Casing
White powder coated sheet steel cover
Heating fluid
Low pressure hot water
Domestic hot water
Potable hot water service
Heat transfer capacity
46kW
Primary flow rate
910 l/h
Minimum flow temperature primary
65ºC
Flow rate
17 l/min
Flow limiter
Internal choke disk at cold water inlet
Fluid temperature in
10ºC
Fluid temperature out
50ºC @ 65ºC primary flow temperature
Blending valve
35-65ºC
Capacity
10kW max. @ 20K ΔT
Maximum primary pressure
6bar
Maximum supply water pressure
10bar
Optimal supply water pressure
2bar
Temperatures
Maximum operating temperature
110ºC
Connections
All external connections
¾"
Strainer (optional)
In primary flow inlet and/or space heating return
(not LogoComfort Basis 600 plus)
Sensor pockets
Sensor pocket in primary flow for optional heat meter
Duty (space heating)
Pressure
Fittings – heating
Fittings – domestic
hot water service
24
Type
Mounting
Heat meter mounting
110mm spool piece in primary return flow
Heat meter (optional)
Rossweiner ‘HeatSonic’ M-Bus heat meter with permanent display
Differential Pressure Control Valve
(optional)
Mounted in primary flow.
Factory set = 30kPa, maximum differential pressure = 250kPa
Primary bypass/trickle bypass
Thermostatic bypass between primary flow and return (adjustable 45-65ºC)
Air vents
Manual
Zone valve
In space heating return flow for optional
electric actuator head mounting kvs = 1.85
Heating control (optional)
Externally mounted electronic room heating control
Control
Proportional flow control with priority switch
Water meter mounting (optional)
110mm spool piece in cold water inlet
Water meter (optional)
Rossweiner water meter, M-Bus
Connection (optional)
Second cold water outlet after water meter
Sanitary circulation (optional)
Sanitary circulation pump Wilo Star-Z Nova
(P max = 4.5W) and external time switch
Dimensions and clearances
Hydraulic layout
4
2
1
M
3
5
13
4
9
6
10
7
8
12
10
800mm
11
Potable
water
600mm
Flow performance
100
90
Primary flow degrees ºC
80
17L of
DHW
@
60
17L of
DHW
@ 50
ºC
17L of
DHW
@ 45
ºC
50
Cold
water
mains
Primary
flow
Primary Heating Heating
flow
return
return
Key
1 Stainless steel plate heat exchanger
2 Proportional Modulation Valve (PMV)
3 Flow restrictor disc 17 l/min
4 Bleed point
5 Zone valve (space heating control unit – optional)
6 Balancer or Differential Pressure Control Valve (DPCV) – optional
7 Thermostatic circulation bridge 45...65ºC – optional
8 Spool piece for heat meter (L=110mm, 2 x ¾" outer thread)
9 ½" blind plug – to be replaced by temp. sensor pocket for
flow sensor (heat meter)
10 Strainer
11 Isolating ball valve ¾" female connection – optional
12 Male connection/thread spool piece for cold water meter
(L=110mm, 2 x ¾" outer thread) – optional
13 Blending valve (thermostatic hot water mixing valve) – optional
210mm
70
DHW
60ºC
40
30
46.6kW/cold water 10ºC
20
53.2kW/cold water 10ºC
65.6kW/cold water 10ºC
10
*The primary flow should not exceed 1,000 l/h
0
0
500
1000
1500
2000
2500
3000
3500
Primary flow rate l/h*
25
PRODUCT DETAILS
MEIBES HIU INDIRECT UNIT
FOR
O U
UFH AND C
CYLINDERS
S
A1 CX BLU-CLIMATE RANGE
26
MEIBES HIU
A1 CX BLU-CLIMATE RANGE
A1 CX units are for use with a separate hot water cylinder and have the capacity to serve
apartments with two bathrooms.
FEATURES & BENEFITS
Designed to suit projects where stored water
is preferred
Compatible with pre-plumbed unvented cylinders
Complete with heat meter
Available with case with window for viewing
heat meter
Also available without case for fitting within an
existing cabinet
Includes high specification Differential Pressure
Control Valve
Top connections for easy contractor access
Flow and primary return test points included
687972
687974
Built-in strainer for unit.
A1 CX Blu-Climate HIU range options
HIU model
With box
With heat meter
Code
Meibes A1 CX Blu-Climate HIU 20K DH & HW HM
Yes
Yes
687970
Meibes A1 CX Blu-Climate HIU 20K DH & HW
Yes
No
687971
Meibes A1 CX Blu-Climate HIU 20K DH & HW HM B
No
Yes
687972
Meibes A1 CX Blu-Climate HIU 20K DH & HW B
No
No
687974
A1 CX Blu-Climate HIU accessory options
Accessory
Code
Meibes A1 CX Fix Rail
687424
Meibes A1 CX Fix Rail and Bypass
687485
27
PRODUCT DETAILS
MEIBES HIU TECHNICAL
& PERFORMANCE
O
C DATA
A1 CX BLU-CLIMATE RANGE
A1 CX Blu-Climate HIU
Technical data
Description
Construction
Duty (primary)
Pressure
Connections
Fittings –
primary side
28
Type
District heating station to be installed in conjunction
with a pre-plumbed unvented cylinder
Mounting
Wall mounted with top or bottom connections
Size (WxDxH, height of the case)
400 x 180 x 500mm
Heating system
2 pipe flow
Pipework
Fully insulated flexible stainless steel with brass fittings
Plate heat exchanger
Fully insulated stainless steel
Casing
White powder coated sheet steel cover
with viewing window for the heat meter
Primary fluid
Low pressure hot water
Secondary fluid
Low pressure hot water
Heat transfer capacity
20kW max. @ 30K ΔT (500 l/h)
Fluid temperature flow
65ºC @ 70ºC primary flow
Fluid temperature return
40ºC
Maximum primary pressure
10bar
Maximum secondary pressure
3bar
All external connections
¾" female ball valves 4x: optional ‘First fix rail’
Strainer
On primary flow
Test points
Binder style test points
Sensor pocket
Primary flow temperature sensor for heat meter
Heat meter
Rossweiner ‘HeatSonic’ M-Bus heat meter with permanent display
Solenoid valve (optional)
Not pre-fitted – fitted via removable spool piece
Differential Pressure Control Valve
(DPCV)
Factory set at 30kPa (maximum differential pressure 250kPa)
Air vents
Manual
Zone valve
Fitted with electrical actuator head
maximum differential pressure 100kPa (kvs=1.85)
Dimensions and clearances
Hydraulic layout
Secondary side
Return
8
Primary side
Flow
Flow
8
Return
8
8
1
1
W
2
5 M
500mm
3
6
7
4
400mm
9 M
180mm
Key
1 Test points
2 Strainer
3 Spool piece for heat meter (L=110mm, 2 x ¾" outer thread)
4 Differential Pressure Control Valve (DPCV)
5 Zone valve
6 Plate heat exchanger
7 Bleed points
8 ¾" ball valves (not illustrated)
9 Solenoid valve (optional)
29
MEIBES HEAT INTERFACE UNIT
TECHNICAL GLOSSARY
Meibes heat interface unit
Features
Designed specifically for UK
30
Benefits
Designed to meet UK requirements to avoid installation and performance issues. Comprehensive spare stocks
available in UK.
Top entry connections
Top entry pipework facilitates pipework runs in ceiling voids for quicker, simpler and more cost effective connection.
First fix rail
Enables faster installation and facilitates staged installation to suit the project timetable and contractor’s schedule.
Also allows earlier primary testing of the main heat network. The first fix rail allows all plumbing connections to be
made, pressure tested, flushed and filled before installation of the main unit, thereby reducing risk of damage and
supporting staged applications for payment where appropriate.
All pipework is pre-insulated
Minimises heat loss for higher energy efficiency, while also improving end user comfort by preventing heat transfer to
property during summer.
Integrated Differential Pressure
Control Valve (DPCV)
Integrated DPCV make the system ‘self balancing’ and ensures each unit only draws as much energy/flow as it requires
in conjunction with a Proportional Modulating Valve. Results in a simpler design with improved control and less noise.
Vertically mounted, un-insulated
Domestic Hot Water heat
exchanger (DHW)
Uninsulated vertical heat exchanger accelerates cooling of DHW heat exchanger through convection and thermal
radiation, minimising limescale formation, maintaining high performance and extending life of units.
Proportional Modulating Valve
(PMV)
Gives priority to DHW generation over space heating to ensure full DHW performance. Primary flow rates are matched
to cold water input.
Carbon coated operating rod in
PM valve, with ceramic disk
Carbon coating provides self lubricating operation, with ceramic disc removing limescale each time the valve operates
to deliver a longer, trouble free, service life.
Indirect energy supply
Separates main primary circuit from secondary circuits, ensuring issues in either do not impact on the other. Also
provides clear demarcation where different contractors are used for primary and secondary circuit installation.
No demand – no flow
With no demand for hot water or heating the unit is effectively on standby with no flow (see trickle bypass). Minimises
demand on main network, reduces energy costs and avoids ‘overheating’ of space where unit is fitted.
‘A-rated’ pump
The electronic pump is an ‘A-rated’ Wilo pump which delivers energy-savings due to only using the minimum amount
of electricity.
Blending valve
Controls maximum temperature of DHW from the heat exchanger at 60ºC. The blend valve allows the temperature to
adjust from 60ºC down to 35ºC depending on the application requirement.
Trickle bypass (included)
Ensures that the prime flow is hot when the unit is switched off, ensuring quicker response times for DHW demand
and eliminating ‘cold legs’ in network where HIUs are some distance from the main network. Avoids need for bypasses
on risers, thereby simplifying network design.
Performance based on lower
primary flow temperatures – 65ºC
Ensures maximum performance with condensing boilers and supports use of low carbon heat sources (e.g. heat
pumps) with lower primary flow temperatures.
Return temperature limited
(RTL) valve
An optional RTL is available if required to allow the return temperature to be limited. This protects the boiler from
excessive temperatures.
Optional factory fitted,
heat meter
Allows accurate measurement of individual energy use. Pressure tested and fitted at factory, reducing on site labour and
risk. Range of options to suit project requirements – ultrasonic or mechanical. M-Bus, radio, manual reading, prepayment.
Potable water circuit
WRAS approved to meet UK requirements and compliant with European Drinking Water directive, in line with Pegler
Yorkshire’s commitment to highest quality and safety.
Warranties
2 year warranty on the unit and moving parts such as pump (on selected units).
Designed for ease of servicing
Ease of access to all components ensures annual servicing can be completed quickly and efficiently.
Reduced lifecycle costs
Product quality and ease of servicing ensure minimal cost of ownership with sustained high efficiency and performance.
Flexible stainless steel pipework
Reduces thermal expansion stresses for quieter operation during warm up and cool down. Easier future servicing
due to flat face connections. In the unlikely event of a need for component replacement, flexible pipework makes
re-connection easier.
Test points
Allows confirmation of flow pressure and temperature.
Strainers on primary and
secondary circuits
Help to capture debris from either circuit, thereby protecting heat exchangers and/or other components, as well as
extending service life. Strainer cleaning is included in annual servicing.
Vertically mounted insulated heat
exchanger for heating circuit
Ensures heating circuit heat exchanger remains at temperature without introducing ‘heat’ to the unit. Lack of cycling
and appropriate water treatments ensure that limescaling is not an issue.
Simple, straightforward
control wiring
External control wiring is similar to a conventional combi boiler and therefore familiar to installers.
Indirect system
A2 RX/A2 UX
Direct system
A1 RX
Indirect for cylinder system
A1 CX
D
D
D
D
D
D
D
³
D
D
D
D
D
D
D
D
D
³
D
D
D
D
D
D
D
D
³
³
D
D
³
³
³
D
³
D
D
³
D
D
D
D
D
D
D
D
D
D
D
D
D
D
³
³
D
D
D
D
D
D
D
³
³
³
D
³
³
D
D
D
D
D
³
D
D
31
DISTRICT HEATING SYSTEMS
CLIMATE CONTROL
Connect with confidence
1
2
Market-leading
Cost effective
Highly versatile
metal push-fit
Exceptional performance
press-fit for the widest
variety of applications.
3
Strong, reliable press-fit
with simple, heat-free
installation
2
MEIBES
BLU-CLIMATE
A2 RX HIU
Indirect DHW
Indirect SH
HEAT
INTERFACE
UNIT
MEIBES
BLU-CLIMATE
A2 UX HIU
1
MEIBES
BLU-CLIMATE
A1 CX HIU
1
32
DATA
EXTRACTION
UNIT
DHW
CYLINDER
HEAT
INTERFACE
UNIT
Indirect DHW
Indirect SH
GAS
5
5
5
HEAT
INTERFACE
UNIT
Indirect DHW
Direct SH
BIOMASS
5
1
1
MEIBES
BLU-CLIMATE
A1 RX HIU
MICRO CHP
5
HEAT
INTERFACE
UNIT
Indirect DHW
Indirect SH
4
5
Mains water
Primary flow
Primary return
Heating flow
Heating return
Potable water
DHW flow
6
6
HEAT EMITTER
5
5
6
DHW flow
6
6
3
6
UNDERFLOOR
HEATING
CIRCUIT
DHW flow
6
HEAT EMITTER
5
6
5
6
DHW flow
6
6
HEAT EMITTER
5
5
6
DHW flow
Putting you in control
4
Commission and
system balancing that
optimises building
system performance
5
Energy-saving
radiator valves that
maximise comfort
6
Elegantly designed,
exceptional quality taps
and showers
33
NOTES
34
35
Pegler Yorkshire
Follow us on
UK ENQUIRIES
UK SALES
Free Phone: 0800 156 0010
Free Fax: 0808 156 1011
Email: [email protected]
TECHNICAL HELP
Free Phone: 0800 156 0050
Free Fax: 0808 156 1012
Email: [email protected]
BROCHURE HOTLINE
Free Phone: 0800 156 0020
Free Fax: 0808 156 1011
Email: [email protected]
INTERNATIONAL ENQUIRIES
EXPORT
Tel: +44 (0) 1302 855 656
Fax: +44 (0) 1302 730 513
Email: [email protected]
HEAD OFFICE
Registered in England Company No. 00401507
Pegler Yorkshire Group Limited
St. Catherine’s Avenue, Doncaster,
South Yorkshire DN4 8DF, England
All brand names and logo styles are registered
trademarks. Maintaining a policy of continual
product development, Pegler Yorkshire reserves
the right to change specifications, design and
materials of products listed in this publication
without prior notice
Tel: +44 (0) 844 243 4400
Fax: +44 (0) 844 243 9870
Email: [email protected]
LIT.REF: 880153.03.14
www.pegleryorkshire.co.uk