LWL-KABEL - Rosenberger OSI

Transcription

LWL-KABEL - Rosenberger OSI
FIBER-OPTIC CABLES
FO-LOOSE TUBE UNIVERSAL CABLE
LWL-KABEL
LWL-BÜNDELADER-UNIVERSALKABEL
TECHNISCHE DATEN - technical data
U-D(ZN)BH KABEL - cable
ANZAHL FASERN - number of fibers
U-DBH UND U-D(ZN)H STANDARDKABEL - standard cable
4
8
12
24
36
48
72
144
KABELAUFBAU
(DIN-VDE 0888)
cable structure
U-DBH
4...
U-DBH
8...
U-DBH
12...
U-DBH
24...*
U-D(ZN)
H 3x12
U-D(ZN)
H 4x12
U-D(ZN)
H 6x12
KABELDURCHMESSER [mm] ca.
cable diameter
7,0
7,0
7,0
7,5
10,5
10,5
GEWICHT [kg/km] weight
48
48
48
55
110
MAX. ZUGFESTIGKEIT
(dauernd) [N]
max. tensile strength (permanent)
1200
1200
1200
1200
MAX. QUERDRUCKFESTIGKEIT
(dauernd) [N/cm]
max. crush resistance (permanent)
150
150
150
MIN. BIEGERADIUS [mm]
min. bending radius
• beim Verlegen - during installation
• im Betrieb - in operation
140
105
140
105
BRANDLAST [MJ/m]
combustion energy
0,7
0,7
VERSTÄRKTER AUFBAU MIT NAGETIERSCHUTZ
cable with rodent protection
4
8
12
24
U-D(ZN)
H 12x12
U-D
(ZN)BH
4...
U-D
(ZN)BH
8...
U-D
(ZN)BH
12...
U-D
(ZN)BH
24...*
11,6
16,3
9,2
9,2
9,2
9,7
110
130
230
105
105
105
115
3000
3000
3000
3000
2500
2500
2500
2500
150
200
200
200
200
300
300
300
300
140
105
150
110
210
160
210
160
230
175
325
245
185
140
185
140
185
140
195
145
0,7
0,72
1,8
1,8
2,1
4,0
0,92
0,92
0,92
1,15
TEMPERATURBEREICH [°C]
temperature range
• Transport und Lagerung
- transport and storage
• beim Verlegen - during installation
• im Betrieb - in operation
Faserdaten (siehe Seite 11)
Fiber data (see page 11)
-25 ... +70
-5 ... +50
-20 ... +60
* Lieferung auch mit verseiltem U-D(ZN)H 2x12- oder 3x8-Aufbau
* Delivery also with stranded loose tube 2x12 – or 3x8-cable
BESTELLNUMMER - part number
U-DBH UND U-D(ZN)H STANDARDKABEL - standard cable
ANZAHL FASERN - number of fibers
E 9/125
G50/125
G62,5/125
4
U-DBH 4...
031A0002
031A0102
031A0202
8
U-DBH 8...
031A0006
031A0106
031A0206
12
U-DBH 12...
031A0010
031A0110
031A0210
24
U-DBH 24...
031A0016
031A0116
031A0216
36
U-D(ZN)H 3x12
031A0022
031A0122
031A0222
48
U-D(ZN)H 4x12
031A0025
031A0125
031A0225
72
U-D(ZN)H 6x12
031A0032
031A0132
031A0232
144
U-D(ZN)H12x12
031A0042
031A0142
031A0242
U-D(ZN)BH KABEL VERSTÄRKTER AUFBAU MIT NAGETIERSCHUTZ - cable with rodent protection
ANZAHL FASERN - number of fibers
E 9/125
G50/125
G62,5/125
4
U-D(ZN)BH 4...
030A0002
030A0102
030A0202
8
U-D(ZN)BH 8...
030A0006
030A0106
030A0206
12
U-D(ZN)BH 12...
030A0010
030A0110
030A0210
24
U-D(ZN)BH 24...
030A0016
030A0116
030A0216
15
Technical Data Sheet
U-DBH n …
Profile view:
Central loose tube
Armour
FRNC-outer jacket
Design:
Cable core:
Gel-filled loose tube, outer diameter 3.5 mm with 2-12 optical
fibres and outer diameter 4.0 mm with 14-24 optical fibres
Tube colour: yellow (E9/125), green (G50/125), blue (G62.5/125)
Fibre colours (1-12): red, green, blue, yellow, white, grey, brown,
violet, turquoise, black, orange, pink
(13-24): red, green, blue, yellow, white, grey, brown,
violet, turquoise, black, orange, pink
(with black ring-marking)
Armour:
Multifunctional E-glass yarns as strain relief element and rodent
protection
Outer jacket:
Halogen-free and flame-retardant material with approx. 1.1 mm wall,
colour: singlemode
yellow
multimode 50 µm
orange or green
multimode 62,5 µm orange
Outer diameter see table below
Marking see a separate drawing
Application/Installation:
Universal cable for both indoor and outdoor with a non-metallic
armouring
The cable is longitudinally water resistant
For fixed installation in cable ducts and in tubes
Mechanical installation by winch is permitted only when using force
meters with recording function
Not suitable for underground laying
Transmission characteristics:
Transmission characteristics see separate fibre data-sheet
Mechanical characteristics:
Min. bending radius
static
15 x outside diameter
dynamic
20 x outside diameter
Max. pull force
1200 N
Max. crush resistance long term
1500 N/dm
Thermal characteristics:
Transport and storage
Installation
In use
Doc.-No.:DS_U-DBHn_L_oe_0012
Valid since: 2003-02-20
Rosenberger OSI Fiber Optics GmbH & Co. KG
- 25 °C to + 70 °C
- 5 °C to + 50 °C
- 20 °C to + 60 °C
Created: 2003-02-20/by:CM
Changed: 2004-03-16/by:CM
Page 1 of 2
Phone: +49 821 24 92 40
Technical Data Sheet
U-DBH n …
Fire performance:
Flame retardancy acc.
to IEC 60332-1
Smoke density acc.
to IEC 61034-1 and 61034-2
Halogen-free acc.
to IEC 60754-2
No corrosive and toxic fumes
Chemical characteristics:
No resistance to oil, petrol, acid and leach
No long time storage in the water permitted
Standardisation:
DIN VDE 0888-6
Fibres
max.
12
24
Outer diam.
mm
7.0
7.5
Weight
kg/km
48
55
Fire load
MJ/m
0.70
0.72
We reserve the right to change or modify any
technical details and specifications.
Doc.-No.:DS_U-DBHn_L_oe_0012
Valid since: 2003-02-20
Rosenberger OSI Fiber Optics GmbH & Co. KG
Created: 2003-02-20/by:CM
Changed: 2004-03-16/by:CM
Page 2 of 2
Phone: +49 821 24 92 40
Technical Data Sheet
U-D(ZN)BH n …
Profile view:
Central loose tube
Armour
Rip cord
FRNC - outer jacket
Design:
Cable core:
Gel-filled loose tube, outer diameter 3.5 mm with 2-12 optical fibres and
outer diameter 4.0 mm with 14-24 optical fibres
Tube colour: yellow (E9/125), green (G50/125), blue (G62.5/125)
Fibre colours (1-12): red, green, blue, yellow, white, grey, brown,
violet, turquoise, black, orange, pink
(13-24): red, green, blue, yellow, white, grey, brown,
violet, turquoise, transparent, orange, pink
(with black ring-marking)
Armour
Multifunctional E-glass yarns, wrapped in two layers (left and right spin)
as strain relief element and non-metallic rodent protection
Outer jacket
Halogen-free and flame-retardant material with approx. 1.7 mm wall,
colour: singlemode
yellow
multimode 50 µm
orange or green
multimode 62,5 µm orange
Outer diameter see table below
Two diametrically opposite ripcords
Marking see a separate drawing
Application/Installation:
Universal cable for both indoor and outdoor with a non-metallic armour
and for enhanced tensile load
For fixed installation in cable ducts and in tubes
Mechanical installation by winch is permitted only when using force
meters with recording function
Not suitable for underground laying
Transmission characteristics:
Transmission characteristics see separate fibre data-sheet
Mechanical characteristics:
Min. bending radius
static
15 x outside diameter
dynamic 20 x outside diameter
Max. pull force
Max. crush resistance long term
Doc.-No.:DS_U-DZNBHn_L_oe_002.doc
Valid since: 2003-02-20
Rosenberger OSI Fiber Optics GmbH & Co. KG
Created: 2003-02-20/by:CM
Changed: 01.12.04/by:EG
2500 N
3000 N/dm
Page 1 of 2
Phone: +49 821 24 92 40
Technical Data Sheet
U-D(ZN)BH n …
Thermal characteristics:
Transport and storage
Installation
In use
- 25 °C to + 70 °C
- 5 °C to + 50 °C
20 °C to + 60 °C
Fire performance:
Flame retardancy acc. to IEC 60332-1
and IEC 60332-3 Cat.A
Smoke density acc. to IEC 61034-1 and 61034-2
Halogen-free acc. to IEC 60754-2
No corrosive and toxic fumes
Circuit integrity:
acc. to IEC 60 331-11 and –25
90 min.
Chemical characteristics:
No resistance to oil, petrol, acid, and leach
No long time storage in the water permitted
Standardisation:
DIN VDE 0888-6
Fibres
max.
12
24
Outer diam.
mm
9,2
9,7
Weight
kg/km
105
115
Fire load
MJ/m
0,26
0,32
We reserve the right to change or modify any
technical details and specifications.
Doc.-No.:DS_U-DZNBHn_L_oe_002.doc
Valid since: 2003-02-20
Rosenberger OSI Fiber Optics GmbH & Co. KG
Created: 2003-02-20/by:CM
Changed: 01.12.04/by:EG
Page 2 of 2
Phone: +49 821 24 92 40
Technical Data Sheet
U-D(ZN)H nxm …
Profile view:
Central strength
Loose
Ripcor
Strain
FRNC-Outer jacket
Design:
Loose tube:
Cable core:
Strain relief:
Gel-filled loose tube, outer diameter 2.4 mm with 2-12 colour-coded
optical fibers
Fiber colours: red, green, blue, yellow, white, grey, brown, violet,
turquoise, black, orange, pink
Central strength member with stranding elements
Tube colours: red, white other tubes:
50/125-green, 62.5/125-blue or 9/125-yellow
Glass yarns, wrapped in two layers (left and right spin)
Outer jacket:
Halogen-free and flame-retardant material with approx. 1.5 mm wall,
colour: singlemode
yellow
multimode 50 µm
orange or green
multimode 62,5 µm orange
Outer diameter see table below
Application/Installation:
Longitudinally water resistant universal cable
Indoor/outdoor cable for the installation in cable ducts and in tubes
Mechanical installation by winch is permitted only when using force
meters with recording function
DIN VDE 0899 applies (german industrial standard)
Not for underground laying
Transmission characteristics:
Transmission characteristics see separate fibre data-sheet
Mechanical characteristics:
Min. bend radius.
static
15 x outside diameter
dynamic 20 x outside diameter
Max. pull force
Max. crush resistance long term
Thermal characteristics:
Fire performance:
Transport and storage
Installation
In use
3000 N
2000 N/dm
- 25 °C to + 70 °C
- 5 °C to + 50 °C
- 20 °C to + 60 °C
Flame retardancy acc.
to IEC 60332-1
Smoke density acc.
to IEC 61034-1 and 61034-2
Halogen-free acc.
to IEC 60754-2
No corrosive and toxic fumes
Doc.-No.:DS_U-D(ZN)Hnxm_L_oe_001
Valid since: 2004-05-11
Rosenberger OSI Fiber Optics GmbH & Co. KG
Created: 2004-05-11/by:CM
Changed: xxxx-xx-xx/by:xx
For technical reasons we must reserve the right for product changes compared to the displayed pictures.
Page 1 of 2
Phone: +49 821 24 92 40
Technical Data Sheet
U-D(ZN)H nxm …
Chemical characteristics:
No resistance to oil, petrol, acid and leach
Standardisation:
DIN VDE 0888-6
IEC 60794-2
1xm
2xm
3xm
4xm
5xm
6xm
8xm
10 x m
10 x m
max.
mm
kg/km
kWh/m
12
24
36
48
60
72
96
120
144
10.5
10.5
10.5
10.5
10.5
11.6
13.1
14.8
16.3
110
110
110
110
110
130
150
190
230
0.5
0.5
0.5
0.5
0.5
0.59
0.62
0.78
0.94
m = 2, 4, 6, 8, 10 or 12 fibers per tube
Doc.-No.:DS_U-D(ZN)Hnxm_L_oe_001
Valid since: 2004-05-11
Rosenberger OSI Fiber Optics GmbH & Co. KG
Created: 2004-05-11/by:CM
Changed: xxxx-xx-xx/by:xx
For technical reasons we must reserve the right for product changes compared to the displayed pictures.
Page 2 of 2
Phone: +49 821 24 92 40
Technical Data Sheet
U-D(ZN)11Y n… for PreCONNECT® MOBILE
Profile view:
Loose tube
Strain relief elements
PUR – outer-jacket
Design:
Cable core:
Loose tube, gel filled ∅ 2.8 mm at 2-12 fibers and
∅ 4.0 mm at 14-24 fibers
colour: yellow (E9/125), green (G50/125), blue (G62.5/125)
Fiber colour coding (1-12): red, green, blue, yellow, white, grey,
brown, violet, turquoise, black,
orange, pink
(13-24): red, green, blue, yellow, white, grey,
brown, violet, transparent, black,
orange, pink
(with ring marking)
Armouring:
Strain relief elements (aramid), two-layer (S and Z)
Outer jacket:
Polyurethane (TPE-U), wall thickness approx. 1.1 mm,
colour: singlemode
yellow
multimode:
orange
Outer diameter: see table below
Application/Installation:
Longitudinally waterproofed universal-cable
For mobile applications
Cable is usable in drag chains
Cable can be used both inside and outside buildings
Installation in cable ducts, on cable trays or cable conduits
The outer jacket has a very high abrasion-resistance
Not for direct burial
Transmission characteristics:
Transmission characteristics see separate fibre data-sheet
Mechanical characteristics:
Min. bending radius
in use (static)
15 x outside diameter
during installation (dynamic)
20 x outside diameter
Max. pull force
2500 N
Max. crush resistance, long term
3000 N/dm
Thermal characteristics:
Transport and storage
Installation
In use
Doc.-No.:DS_U-DZN11Yn_L_oe_002.doc
Valid since: 2004-03-28
Rosenberger OSI Fiber Optics GmbH & Co. KG
Created: 2004-03-28/by:CM
Changed: 2004-12-01/by:EG
For technical reasons we must reserve the right for product changes compared to the displayed pictures.
- 40 °C to + 70 °C
- 25 °C to + 50 °C
- 35 °C to + 70 °C
Page 1 of 2
Phone: +49 821 24 92 40
Technical Data Sheet
U-D(ZN)11Y n… for PreCONNECT® MOBILE
Fire performance:
Cable is flame retardend
Halogen-free acc. to IEC 60754-2
No corrosive and toxic fumes
Chemical characteristics:
Very good resistance to oil, petrol, acid and leach
Standardisation:
DIN VDE 0888-6
IEC 60 974-2
No. of
fibres
12
24
Doc.-No.:DS_U-DZN11Yn_L_oe_002.doc
Valid since: 2004-03-28
Rosenberger OSI Fiber Optics GmbH & Co. KG
outer diam.
mm
6,5
7,7
Weight
kg/km
36
50
Created: 2004-03-28/by:CM
Changed: 2004-12-01/by:EG
For technical reasons we must reserve the right for product changes compared to the displayed pictures.
Page 2 of 2
Phone: +49 821 24 92 40