Outside Plant

Transcription

Outside Plant
O UTSIDE PLANT
OUTSIDE
PLANT
Cables
Index
OUTSIDE PLANT CABLES: TELEPHONE/FIBER/COAXIAL
CONTENTS
•
•
•
•
•
•
•
•
•
•
FILLED SOLID ALPETH CABLE
FILLED FOAM SKIN ALPETH CABLE
FILLED FOAM SKIN CACSP CABLE
AIRCORE ALPETH CABLE
DOUBLE JACKETED BURIED DISTRIBUTION WIRE
FILLED ASP CABLE, FOAM SKIN INSULATION
BURIED SERVICE WIRE
DOUBLE JACKETED BURIED DISTRIBUTION WIRE
BURIED SERVICE WIRE
AERIAL SERVICE WIRE
1
3
5
7
9
11
13
15
17
19
•
•
•
•
ARMORED MACROTEL OPTICAL CABLE
DRY DIELECTRIC MACROTEL OPTICAL CABLE
DIELECTRIC DJ MACROTEL OPTICAL CABLE
DRY LIGHT ARMORED MACROTEL OPTICAL CABLE
20
21
22
23
•
•
•
•
1/2” (12.7mm) RF COAXIAL CABLE
7/8” (22.2mm) RF COAXIAL CABLE
1-1/4” (31.75mm) RF COAXIAL CABLE
1-5/8” (41.275mm) RF COAXIAL CABLE
24
25
26
27
• TRUNK AND DISTRIBUTION CABLE
Condumex Wire and Cable
28
2590 114th Street, #200 - Grand Prairie, TX 75050 (800) 925-9473
11-03
1
I. Exchange Cables
Filled Solid ALPETH Cable
REA/RUS
PE-39
62.39.01
CONDUCTORS:
Solid, annealed copper wires, in 26, 24,
22 and 19 AWG.
INSULATION:
Solid, high-density polyethylene or polypropylene in distinctive colors, conforming to
telephone industry standards.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths to minimize capacitance unbalance
and crosstalk.
CORE ASSEMBLY:
In cables with 25 pairs or less, the pairs
are laid forming a cylindrical shape. For
larger cables, units of 25 pairs or
superunits of 50 or 100 pairs are assembled to form the final core. The core is
filled with ETPR (80°C) compound. Then
covered with a non-hygroscopic tape with
an overlap. A filling compound is applied
over the wrap.
All units and superunits are identified with
color coded, non-hygroscopic, non-wicking
binders. In order to have a rounder shape
and better electrical performance, all units
and superunits are divided into 12 and 13
pair sub-units.
SHIELD:
Corrugated, copolymer coated, 8-mil thick
aluminum tape applied longitudinally with
an overlap. The coating reduces the risk of
shield corrosion. A flooding compound with
adhesive properties is applied over the shield.
JACKET:
Black, linear, low-density, high molecular
weight polyethylene. Sequential footage (or
meter) markings are printed on the jacket
at 2 foot (or 1 m) intervals.
Outside plant telephony or underground installation.
Meets REA/RUS PE-39
ANSI/ICEA S-84-608-1994.
Standard for Telecommunications Cable Filled, Polyolefin Insulated,
Copper Conductor.
Telecordia (Bellcore) equivalent: none
ISO-9001 Quality Assurance System
Packaged on wooden reels with a thermal wrap applied over the cable.
The reels are also lagged for additional protection.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
1
26 AWG
Product
Code
Number of
Pairs
In
Nominal OD
mm
Approximate Cable Weight
Lbs/kft
Kg/km
Standard Length
Ft
m
625152
625153
625154
625156
625157
625158
625159
625160
625161
625162
25
50
100
200
300
400
600
900
1200
1800
0.61
0.75
0.95
1.22
1.44
1.61
1.89
2.26
2.70
3.21
15.5
19.0
24.0
31.0
36.5
41.0
48.0
57.5
68.5
81.5
159
257
434
782
1114
1428
2927
2944
4003
5819
237
384
647
1166
1661
2129
3023
4390
5970
8678
5000
5000
3000
3000
3000
3000
1500
1000
1000
650
1525
1525
915
915
915
915
460
305
205
200
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626168
626169
626170
626171
626172
626173
626174
626196
626177
626178
626179
626180
626181
6
12
18
25
50
75
100
200
300
400
600
900
1200
0.47
0.59
0.67
0.75
0.89
1.04
1.16
1.48
1.71
1.95
2.35
2.81
3.23
12.0
15.0
17.0
19.0
22.5
26.5
29.5
37.5
43.5
69.5
60.0
71.5
82.0
107
157
198
241
402
563
701
1261
1794
2260
3282
4727
5687
160
235
295
360
600
840
1045
1880
2675
3370
4895
7050
8481
5000
5000
5000
5000
5000
5000
3000
3000
3000
1650
1650
1000
650
1525
1525
1525
1525
1525
1525
915
915
915
500
500
305
200
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626188
626189
626190
626191
626192
626193
626194
626196
626197
626198
626199
6
12
18
25
50
75
100
200
300
400
600
0.57
0.67
0.75
0.85
1.04
1.22
1.38
1.75
2.13
2.40
2.87
14.5
17.0
19.0
21.5
26.5
31.0
35.0
44.5
54.0
61.0
73.0
134
201
228
342
563
798
1019
1797
2625
3997
4976
200
300
340
510
840
1190
1520
2680
3915
5960
7420
5000
5000
5000
5000
3000
3000
3000
1650
1650
1000
1000
1525
1525
1525
1525
1525
915
915
500
500
305
305
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626205
626206
626207
626208
626209
626210
626211
626213
626214
6
12
18
25
50
75
100
200
300
0.71
0.85
0.96
1.06
1.42
1.66
1.83
2.48
2.95
18.0
21.5
24.5
27.0
36.0
42.0
46.5
63.0
75.0
211
349
466
590
1059
1485
1921
3557
5197
315
520
695
880
1580
2215
2865
5305
7750
5000
5000
5000
5000
3000
3000
3000
1000
650
1525
1525
1525
1525
915
915
915
305
200
24 AWG
Nominal OD
Approximate Cable Weight
Standard Length
22 AWG
Nominal OD
Approximate Cable Weight
Standard Length
19 AWG
2
Nominal OD
Approximate Cable Weight
Standard Length
Note: Values shown are nominal, subject to manufacturing tolerances.
Special lengths are available upon request.
I. Exchange Cables
Filled Foam Skin ALPETH Cable
REA/RUS
PE-89
62.89.01
CONDUCTORS:
Solid, annealed copper wires, in 26, 24,
22 AND 19 AWG.
INSULATION:
Expanded polyethylene (Foam Skin) with an
external layer of solid, high-density polyethylene in distinctive colors, conforming to
telephone industry standards.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths to minimize capacitance unbalance
and cross-talk.
All units and superunits are identified with
color coded, non-hygroscopic, non-wicking
binders. In order to have a rounder shape
and better electrical performance, all units
and super-units are divided into 12 and 13
pairs sub-units.
SHIELD:
Corrugated, copolymer coated, 8-mil thick
aluminum tape applied longitudinally with
an overlap. The coating reduces the risk of
shield corrosion. A flooding compound with
adhesive properties is applied over the
shield.
JACKET:
Black, linear, low-density, high molecular
weight polyethylene. Sequential footage (or
meter) markings are printed on the jacket
at 2 foot (or 1 m) intervals.
CORE ASSEMBLY:
In cables with 25 pairs or less, the pairs
are laid forming a cylindrical shape. For
larger cables, units of 25 pairs or
superunits of 50 or 100 pairs are assembled to form the final core. The core is
filled with ETPR (80° C) compound. Then
covered with a non-hygroscopic tape with
an overlap. A filling compound is applied
over the wrap.
Outside plant telephony or underground installation.
Meets REA/RUS PE-89
ANSI/ICEA S-84-608-1994.
Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
Telecordia (Bellcore) equivalent: AN_A
ISO-9001 Quality Assurance System
Packaged on wooden reels with a thermal wrap applied over the cable.
The reels are also lagged for additional protection.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
3
26 AWG
Product
Code
Number of
Pairs
Nominal OD
Approximate Cable Weight
Standard Length
In
mm
Lbs/kft
Kg/km
Ft
m
626081
626082
626083
626084
626086
626087
626088
626089
626090
626091
626093
626095
25
50
75
100
200
300
400
600
900
1200
1800
2400
0.55
0.59
0.77
0.89
1.08
1.30
1.46
1.69
1.93
2.30
3.00
3.19
14.0
15.0
19.5
22.5
27.5
33.0
37.0
43.0
49.0
58.5
76.0
81.0
137
228
302
369
650
925
1153
1686
2411
3239
4764
6246
205
340
450
550
970
1380
1720
2515
3640
4830
7105
9315
4920
4920
4920
4920
4920
4920
3280
1640
1640
985
655
655
1500
1500
1500
1500
1500
1500
100
500
500
300
200
200
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626101
626102
626103
626104
626105
626106
626107
626109
626110
626111
626112
626113
626114
6
12
18
25
50
75
100
200
300
400
600
900
1200
0.45
0.51
0.59
0.67
0.77
0.87
0.96
1.20
1.54
1.71
2.05
2.52
2.91
11.5
13.0
15.0
17.0
19.5
22.0
24.5
30.5
39.0
43.5
52.0
64.0
74.0
70
107
144
194
302
396
506
949
1368
1680
2515
3628
5123
105
160
215
290
450
590
755
1415
2040
2505
3750
5410
7460
4920
4920
4920
4920
4920
4920
4920
3280
3280
2950
1640
1640
655
1500
1500
1500
1500
1500
1500
1500
1000
1000
900
500
500
200
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626120
626121
626122
626123
626124
626125
626126
626128
626129
626130
626131
626132
6
12
18
25
50
75
100
200
300
400
600
900
0.47
0.59
0.67
0.81
0.94
1.14
1.22
1.65
1.91
2.03
2.62
3.15
12.0
15.0
17.0
20.5
24.0
29.0
31.0
42.0
48.5
51.5
66.5
80.0
87
137
211
302
453
644
771
1482
2106
2602
4090
6025
130
205
315
450
675
960
1150
2210
3140
3880
6100
8985
4920
4920
4920
4920
4920
4920
4920
3280
1640
1640
985
655
1500
1500
1500
1500
1500
1500
1500
1000
500
500
300
200
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626136
626137
626138
626139
626140
626141
626143
626144
626145
6
12
18
25
50
75
100
200
300
0.59
0.71
0.81
0.91
1.16
1.32
1.50
2.01
2.36
15.0
18.0
20.5
23.0
29.5
33.5
38.0
51.0
60.0
141
231
308
409
744
1063
1368
2635
3856
210
345
460
610
1110
1585
2040
3930
5750
4920
4920
4920
4920
3280
3280
1640
1640
985
1500
1500
1500
1500
1000
1000
500
500
300
24 AWG
Nominal OD
Approximate Cable Weight
Standard Length
22 AWG
Nominal OD
Approximate Cable Weight
Standard Length
19 AWG
4
Nominal OD
Approximate Cable Weight
Standard Length
Note: Values shown are nominal, subject to manufacturing tolerances.
Special lengths are available upon request.
I. Exchange Cables
Filled Foam Skin CACSP Cable
REA/RUS
PE-89
62.89.02
CONDUCTORS:
Solid, annealed copper wires, in 26, 24,
22 and 19 AWG.
INSULATION:
Expanded polyethylene (Foam Skin) with an
external layer of solid, high-density polyethylene in distinctive colors, conforming to
telephone industry standards.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths to minimize capacitance unbalance
and cross-talk.
CORE ASSEMBLY:
In cables with 25 pairs or less, the pairs
are laid forming a cylindrical shape. For
larger cables, units of 25 pairs or
superunits of 50 or 100 pairs are assembled to form the final core. The core is
filled with ETPR (80°C) compound. Then
covered with a non-hygroscopic tape with
an overlap. Filling compound is also applied
over the wrap.
All units and superunits are identified with
color coded, non-hygroscopic, non-wicking
binders. In order to have a rounder shape
and better electrical performance, all units
and superunits are divided into 12 and 13
pairs sub-units.
SHIELD:
Corrugated, copolymer coated aluminum
tape, 8-mil thick applied longitudinally with
a gap. A flooding compound is applied over
the shield.
ARMOR:
Corrugated shield of copolymer coated
steel tape, 6-mil thick. A flooding compound with adhesive properties is applied
over the armor.
JACKET:
Black, linear, low-density, high molecular
weight polyethylene. Sequential footage (or
meter) markings are printed on the jacket
at 2 foot (or 1 m) intervals.
Outside plant telephony, direct burial or underground installation.
Meets REA/RUS PE-89
ANSI/ICEA S-84-608-1994.
Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
Telecordia (Bellcore) equivalent: AN W
ISO-9001 Quality Assurance System
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
5
26 AWG
Product
Code
Number of
Pairs
In
Nominal OD
mm
Approximate Cable Weight
Lbs/kft
Kg/km
Standard Length
Ft
m
626280
626281
626282
626283
626285
626286
626287
626288
626290
626292
626294
626296
25
50
75
100
200
300
400
600
900
1200
1800
2400
0.51
0.59
0.75
0.87
1.08
1.30
1.40
1.63
2.28
2.83
3.15
13.0
15.0
19.0
22.0
27.0
32.0
35.5
41.5
49.0
58.0
72.0
80.0
145.0
235
312
386
690
925
1156
1230
1740
2548
3382
4964
6256
215
350
465
574
1027
1436
1830
2589
3790
5032
7386
9309
4920
4920
4920
4920
4920
4920
3280
1640
1640
985
655
655
1500
1500
1500
1500
1500
1500
100
500
500
300
200
200
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626300
626301
626302
626303
626304
626305
626306
626308
626309
626310
626311
626313
626315
6
12
18
25
50
75
100
200
300
400
600
900
1200
0.40
0.51
0.57
0.65
0.75
0.87
0.94
1.18
1.50
1.69
1.97
2.44
2.84
11.0
13.0
14.5
16.5
19.0
22.0
24.0
30.0
38.0
43.0
50.0
62.0
72.0
89
127
164
198
322
439
546
997
1383
1820
2615
3878
5163
132
189
244
295
480
653
812
1484
2058
2708
3891
5770
7683
4920
4920
4920
4920
4920
4920
4920
4920
3280
3280
2950
1640
1640
655
1500
1500
1500
1500
1500
1500
1500
1000
1000
900
500
500
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626320
626321
626322
626323
626324
626325
626326
626328
626329
626330
626331
626333
6
12
18
25
50
75
100
200
300
400
600
900
0.47
0.59
0.67
0.77
0.91
1.06
1.22
1.54
1.77
2.03
2.50
3.03
12.0
15.0
17.0
19.5
23.0
27.0
31.0
39.0
45.0
51.5
63.5
77.0
104
167
221
287
478
644
831
1482
2106
2732
4090
6120
155
248
329
427
711
960
1237
2210
3140
4055
6100
9107
4920
4920
4920
4920
4920
4920
4920
3280
1640
1640
985
655
1500
1500
1500
1500
1500
1500
1500
1000
500
500
300
200
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626340
626341
626342
626343
626344
626345
626346
626348
626349
6
12
18
25
50
75
100
200
300
0.59
0.71
0.85
0.91
1.16
1.32
1.50
2.01
2.36
15.0
18.0
21.5
23.0
29.5
33.5
38.0
51.0
60.0
141
231
308
409
744
1063
1368
2635
3856
210
345
460
610
1110
1585
2040
3930
5750
4920
4920
4920
4920
3280
3280
1640
1640
985
1500
1500
1500
1500
1000
1000
500
500
300
24 AWG
Nominal OD
Approximate Cable Weight
Standard Length
22 AWG
Nominal OD
Approximate Cable Weight
Standard Length
19 AWG
6
Nominal OD
Approximate Cable Weight
Standard Length
Note: Values shown are nominal, subject to manufacturing tolerances.
Special lengths are available upon request.
I. Exchange Cables
Aircore ALPETH Cable
REA/RUS
PE-22
62.22.01
CONDUCTORS:
Solid, annealed copper wires, in 26, 24
22 and 19 AWG.
In order to have a rounder shape and
better electrical performance, all units and
superunits are divided into 12 and 13
pairs sub-units.
INSULATION:
Solid, high-density polyethylene or polypropylene in distinctive colors, conforming to
telephone industry standards.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths to minimize capacitance unbalance
and crosstalk.
CORE ASSEMBLY:
In cables with 25 pairs or less, the pairs
are laid forming a cylindrical shape. For
larger cables, units of 25 pairs or
superunits of 50 or 100 pairs are assembled to form the final core. All units
and superunits are identified with color
coded, non-hygroscopic, non-wicking
binders.
SHIELD:
Corrugated, copolymer coated, 8-mil thick
aluminum tape applied longitudinally with
an overlap. The coating reduces the risk of
shield corrosion.
JACKET:
Black, linear, low-density, high molecular
weight polyethylene. Sequential footage (or
meter) markings are printed on the jacket
at 2 foot (or 1 m) intervals.
Meets REA/RUS PE-22
ANSI/ICEA S-85-625-1996
Standard for Telecommunications Cable Air Core, Polyolefin Insulated,
Copper Conductor.
Telecordia (Bellcore) equivalent: BH A
ISO-9001 Quality Assurance System
Packaged on wooden reels with a thermal wrap applied over the cable.
The reels are also lagged for additional protection.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
7
26 AWG
Product
Code
Number of
Pairs
626001
626002
626003
626004
626005
626006
626007
626008
626009
626010
626011
626012
626013
626014
626015
626016
626017
12
18
25
50
75
100
150
200
300
400
600
900
1200
1500
1800
2100
2400
In
0.45
0.47
0.51
0.63
0.71
0.77
0.89
1.01
1.14
1.39
1.54
1.85
2.13
2.34
2.56
2.74
2.93
Nominal OD
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626025
626026
626027
626028
626029
626030
626031
626032
626033
626034
626035
626036
626037
626038
626039
626040
6
12
18
25
50
75
100
150
200
300
400
600
900
1200
1500
1800
0.39
0.47
0.51
0.55
0.71
0.81
0.87
1.04
1.18
1.40
1.57
1.87
2.28
2.60
2.85
3.11
10.0
12.0
13.0
14.0
18.0
20.5
22.0
26.5
30.0
35.5
40.0
47.5
58.0
66.0
72.5
79.0
62
81
107
133
225
314
396
596
767
1114
1447
2120
3153
4120
5085
6052
93
121
160
199
336
468
591
889
1144
16961
2158
3162
4702
6145
7583
9026
4920
4920
4920
4920
4920
4920
4920
3940
3940
3940
2950
1970
985
985
985
655
1500
1500
1500
1500
1500
1500
1500
1200
1200
1200
900
600
300
300
300
200
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626048
626049
626050
626051
626052
626053
626054
626055
626056
626057
626058
626059
6
12
18
25
50
75
100
150
200
300
400
600
0.43
0.52
0.55
0.63
0.79
0.91
1.04
1.22
1.38
1.63
1.87
2.32
11.0
13.0
14.0
16.0
20.0
23.0
26.5
31.0
35.0
41.5
47.5
59.0
76
115
148
190
329
460
607
895
1163
1688
2218
3292
114
171
221
284
490
686
905
1335
1734
2518
3308
4309
4920
4920
4920
4920
4920
4920
3940
3940
3940
2950
1970
985
1500
1500
1500
1500
1500
1500
1200
1200
1200
900
600
300
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626065
626066
626067
626068
626069
626070
626071
626072
626073
6
12
18
25
50
75
100
150
200
0.55
0.67
0.77
0.85
1.12
1.28
1.50
1.81
2.07
14.0
17.0
19.5
21.5
28.5
32.5
38.0
46.0
52.5
125
198
268
347
636
899
1186
1768
2326
187
295
400
517
949
1341
768
2637
3469
4920
4920
4920
3280
3280
3280
1970
1970
1970
1500
1500
1500
1000
1000
1000
600
600
600
mm
11.5
12.0
13.0
16.0
18.0
19.5
22.5
25.5
29.0
33.0
39.3
47.0
54.0
59.5
65.0
69.5
74.5
Approximate Cable Weight
Lbs/kft
72
87
106
167
224
280
405
529
749
968
1405
2055
2692
3319
3964
4579
5206
Kg/km
106
130
158
248
334
418
604
789
1113
1443
2095
3065
4014
4949
5912
6828
7763
Standard Length
Ft
4920
4920
4920
4920
4920
4920
4920
3940
3940
3940
2950
1970
1310
985
985
985
985
m
1500
1500
1500
1500
1500
1500
1500
1200
1200
1200
900
600
400
300
300
300
300
24 AWG
Nominal OD
Approximate Cable Weight
Standard Length
22 AWG
Nominal OD
Approximate Cable Weight
Standard Length
19 AWG
8
Nominal OD
Approximate Cable Weight
Standard Length
Note: Values shown are nominal, subject to manufacturing tolerances.
Special lengths are available upon request.
II. Buried Wire
Double Jacketed Buried Distribution Wire
(Gopher resistent)
PE-86
62.86.01
CONDUCTORS:
Solid, annealed 22 AWG copper with a
nominal diameter of 0.0250” (0.634 mm)
INNER JACKET
Black, linear, low-density, high molecular
weight polyethylene.
INSULATION:
Solid, high-density, polyethylene or polypropylene in distinctive colors, conforming to
telephone industry standards.
SHIELD:
Corrugated, copper-clad alloy steel (0.005”
thick) tape applied longitudinally with an
overlap. A flooding compound is applied on
both sides of the tape.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths, with a maximum length of 6.5”
(165 mm).
OUTER JACKET:
Black, linear, low density, high molecular
weight polyethylene. Sequential footage (or
meter) markings are printed on the jacket
at 2 foot (or 1 m) intervals.
CORE ASSEMBLY:
The core is filled with ETPR (80°C) compound, then covered with a non-hygroscopic tape with an overlap. A filling
compound is also applied over the wrap.
Service drop for telephony, underground installation or direct burial.
ANSI/ICEA S-86-634-1991
Standard for Telecommunications Cable Filled, Polyolefin Insulated, Cooper Conductor.
Meets REA/RUS PE-86 (for 2 and 3 pair, 22 AWG when a bronze shield - BDW B
or when a cooper clad steel armor - BDW G DJ is used)
ISO-9001 Quality Assurance System
Packaged on wooden reels that are lagged for additional protection.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
9
II. Buried Wire
Double Jacketed Buried Distribution Wire
(Gopher resistent)
PE-86
62.86.01
MECHANICAL PROPERTIES
Number
Of
Pairs
Nominal
OD
In
Mm
Cable Net Weight
Shipping Length
Approximate
Shipping Weight
Lbs
kg
Lbs/kft
kg/km
FT
m
2
0.40
10.3
94
140
2500 or
5000
760 or
1520
292
558
132
253
3
0.44
11.1
110
162
2500 or
5000
760 or
1520
329
633
149
287
6
0.51
12.9
149
222
1000 or
2500 or
5000
305 or
760 or
1520
206
435
873
93
197
396
Note: Values shown are nominal, subject to manufacturing tolerances.
ELECTRICAL CHARACTERISTICS
MUTUAL CAPACITANCE, average
83+7 nF/mile
-
CAPACITANCE UNBALANCE: Pair to pair
Maximum Individual
80 pF/kft
145 pF/km
CAPACITANCE UNBALANCE: Pair to Ground
Individual Maximum
800 pF/kft
2625 pF/km
FEXT Far end CROSSTALK, dB/kft minimum Power Sum
@150 kHz
63
NEXT Near end CROSSTALK, dB/kft minimum Power Sum
@772 kHz
44
ATTENUATION @ 150 kHz @ 20°C, Maximum Individual
10
52+4 nF/km
Nominal dB/kft
Nominal dB/km
11.0
6.8
HIGH VOLTAGE TEST, d-c kV for 3 seconds
Conductor to Conductor
Conductor to Shield
5.0
20.0
D-c CONDUCTOR RESISTANCE @ 20°C, Maximum Individual
Ù/kft
Ù/km
RESISTANCE UNBALANCE
Maximum Individual
Maximum Average
5%
1.5%
INSULATION RESISTANCE, Minimum
MÙ · Mile
MÙ · km
1,000
1,600
17.4
57.1
I. Exchange Cables
Filled ASP Cable, Foam Skin Insulation
AN_W
Telecordia (Bellcore)
62.AN_W.01
DESCRIPTION:
CONDUCTORS:
Solid, annealed copper wires, in 26, 24,
22 and 19 AWG.
INSULATION:
Expanded polyethylene (Foam Skin) with an
external layer of solid, high-density polyethylene in distinctive colors, conforming to
telephone industry standards.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths to minimize capacitance unbalance
and cross-talk.
CORE ASSEMBLY:
In cables with 25 pairs or less, the pairs
are laid forming a cylindrical shape. For
larger cables, units of 25 pairs or superunits of 50 or 100 pairs are assembled to
form the final core. The core is filled with
ETPR (80°C) compound. Then covered with
a non-hygroscopic tape with an overlap.
Filling compound is also applied over the
wrap.
All units and superunits are identified with
color coded, non-hygroscopic, non-wicking
binders. In order to have a rounder shape
and better electrical performance, all units
and super-units are divided into 12 and 13
pair sub-units.
SHIELD:
Corrugated, bare aluminum tape, 8-mil
thick applied longitudinally with an overlap.
A flooding compound with adhesive
properties is applied over the shield.
ARMOR:
A corrugated shield of steel tape, 6-mil
thick.
JACKET
Black, linear, low-density, high molecular
weight polyethylene. Sequential footage (or
meter) markings are printed on the jacket
at 2 foot (or 1 m) intervals.
APPLICATION:
Outside plant telephony, direct burial or underground installation.
REFERENCE SPECIFICATIONS:
Telecordia (Bellcore)
TR-NWT-00421/3.
ANSI/ICEA 84-608-1988
Generic Requirements for metallic telecommunication cables.
CERTIFICATION:
ISO-9001 Quality Assurance System
PACKAGING:
Packaged on wooden reels with a thermal wrap applied over the cable.
The reels are also lagged for additional protection.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
11
26 AWG ANTW
Product
Code
Number of
Pairs
In
Nominal OD
mm
Approximate Cable Weight
Lbs/kft
Kg/km
Standard Length
Ft
m
626220
626221
626223
626225
626226
626227
626228
626229
626230
626231
626232
25
50
100
200
300
400
600
900
1200
1800
2400
0.63
0.79
0.94
1.22
1.36
1.54
1.75
2.07
2.60
2.89
3.27
16.0
20.0
24.0
31.0
34.5
39.0
44.5
52.5
66.0
73.5
83.0
170
260
395
724
972
1240
1608
2513
3652
4256
6231
255
385
590
1080
1450
1850
2400
3750
5450
6350
9300
5900
5900
5900
5900
3940
3940
2950
1970
1475
985
820
1800
1800
1800
1800
1200
1200
900
600
450
300
250
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626238
626239
626241
626243
626244
626245
626246
626247
626248
626250
25
75
100
200
300
400
600
900
1200
1800
0.73
0.87
1.04
1.36
1.57
1.81
2.11
2.56
2.99
3.56
18.5
22.0
26.5
34.5
40.0
46.0
53.5
65.0
76.0
90.5
241
349
550
972
1408
1864
2548
3805
5076
7631
360
520
820
1450
2100
2780
3800
5675
7570
11,380
5900
5900
5900
3940
3940
3280
2950
1475
1475
655
1800
1800
1800
1200
1200
1000
900
450
450
200
24 AWG
Nominal OD
Approximate Cable Weight
Standard Length
22 AWG
Product
Code
Number of
Pairs
626250
626251
626252
626254
626255
626256
626257
626258
25
50
100
200
300
400
600
900
In
0.85
1.02
1.26
1.57
1.93
2.20
2.66
3.19
Nominal OD
Product
Code
Number of
Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626265
626266
626267
626268
626270
626271
626272
25
50
75
100
200
300
400
1.02
1.22
1.42
1.52
2.13
2.54
2.87
26.0
31.0
36.0
38.5
54.0
64.5
73.0
532
896
1228
1498
2895
4168
5423
793
1336
1832
2234
4318
6216
8088
4920
3280
3280
3280
1640
985
655
1500
1000
1000
1000
500
300
200
mm
21.5
26.0
32.0
42.5
49.0
56.0
67.5
81.0
Approximate Cable Weight
Lbs/kft
322
489
831
1408
2045
2749
3856
5633
Kg/km
480
730
1240
2100
3050
4100
5750
8400
Standard Length
Ft
5900
5900
3740
2950
2950
1970
1475
820
m
1800
1800
1200
900
900
600
450
250
19 AWG ANBW
12
Nominal OD
Approximate Cable Weight
Standard Length
Note: Values shown are nominal, subject to manufacturing tolerances.
Special lengths are available upon request.
II. Buried Wire
Buried Service Wire
(Aluminium shield, single jacket)
BSW A
62.BSW.01
CONDUCTORS:
Solid, annealed 22 AWG copper with a
nominal diameter 0.0250” (0.634mm)
INSULATION:
Solid, high-density, polyethylene or polypropylene in distinctive colors, conforming to
telephone industry standards.
SHIELD:
Smooth, copolymer coated, 8-mil thick
aluminum tape applied longitudinally with
an overlap. The coating reduces the risk of
shield corrosion. A flooding compound with
adhesive properties is applied over the
shield.
JACKET:
Black, linear, low-density, high molecular
weight polyethylene, able to withstand
exposure to sunlight, ground humidity and
chemicals. Sequential footage (or meters)
markings are printed on the jacket at 2
foot (or 1 m) intervals.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths, with a maximum length of 6.5”
(165 mm).
CORE ASSEMBLY:
The core is filled with ETPR (80°C)
compound. Then covered with a nonhygroscopic tape with an overlap. A filling
compound is also applied over the wrap.
Service drop for telephony, underground installation or in ducts.
ANSI/ICEA S-86-634-1991
Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
ISO-9001 Quality Assurance System
Packaged on wooden reels that are lagged for additional protection
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
13
II. Buried Wire
Buried Service Wire
(Aluminium shield, single jacket)
BSW A
62.BSW.01
Number
Of
Pairs
Nominal
OD
In
Mm
Cable Net Weight
Shipping Length
Approximate
Shipping Weight
Lbs
kg
Lbs/kft
kg/km
FT
m
2
0.29
7.4
39
58
2500
762
139
63
3
0.32
8.2
48
72
2500
762
164
75
Note: Values shown are nominal, subject to manufacturing tolerances.
MUTUAL CAPACITANCE, average
83+7 nF/mile
-
CAPACITANCE UNBALANCE: Pair to pair
Maximum Individual
80 pF/kft
145 pF/km
CAPACITANCE UNBALANCE: Pair to Ground
Individual Maximum
800 pF/kft
2625 pF/km
FEXT Far end CROSSTALK, dB/kft minimum Power Sum
@150 kHz
63
NEXT Near end CROSSTALK, dB/kft minimum Power Sum
@772 kHz
44
ATTENUATION @ 150 kHz @ 20°C, Maximum Individual
Nominal dB/kft
Nominal dB/km
HIGH VOLTAGE TEST, d-c kV for 3 seconds
Conductor to Conductor
Conductor to Shield
14
52+4 nF/km
11.0
6.8
5.0
10.0
D-c CONDUCTOR RESISTANCE @ 20°C, Maximum Individual
Ù/kft
Ù/km
RESISTANCE UNBALANCE
Maximum Individual
Maximum Average
5%
1.5%
INSULATION RESISTANCE, Minimum
MÙ · Mile
MÙ · km
1,000
1,600
17.4
57.1
II. Buried Wire
Double Jacketed Buried Distribution Wire
(Aluminium shield, double polyethylene jacket)
BDW A
62.BDW_A.01
DESCRIPTION:
CONDUCTORS:
Solid, annealed 22 AWG copper with a
nominal diameter of 0.0250” (0.634mm)
INNER JACKET
Black, linear, low-density, high molecular
weight polyethylene.
INSULATION:
Solid, high-density, polyethylene or polypropylene in distinctive colors, conforming to
telephone industry standards.
SHIELD:
Smooth, copolymer coated, 8-mil thick
aluminum tape applied longitudinally with
an overlap. The coating reduces the risk of
shield corrosion. A flooding compound with
adhesive properties is applied over the
shield.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths, with maximum length of 6.5”
(165 mm).
JACKET:
Black, linear, low-density, high molecular
weight polyethylene, able to withstand
exposure to sunlight, ground humidity and
chemicals. Sequential footage (or meter)
markings are printed on the jacket at 2
foot (or 1 m) intervals.
CORE ASSEMBLY:
The core is filled with ETPR (80°C)
compound. Then covered with a nonhygroscopic tape with an overlap. A filling
compound is also applied over the wrap.
APPLICATION:
Service drop for telephony, underground installation.
REFERENCE SPECIFICATIONS:
ANSI/ICEA S-86-634-1991
Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
CERTIFICATION:
ISO-9001 Quality Assurance System
PACKAGING:
Packaged on wooden reels that are lagged for additional protection.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
15
II. Buried Wire
Double Jacketed Buried Distribution Wire
(Aluminium shield, double polyethylene jacket)
BDW A
62.BDW_A.01
MECHANICAL PROPERTIES
Number
Of
Pairs
Nominal
OD
In
Mm
Cable Net Weight
Shipping Length
Approximate
Shipping Weight
Lbs
kg
Lbs/kft
kg/km
FT
m
2
0.35
8.9
52
62
2500
762
183
83
3
0.38
9.7
63
75
5000
1524
375
170
6
0.46
11.6
94
107
1000
305
148
67
Note: Values shown are nominal, subject to manufacturing tolerances.
ELECTRICAL CHARACTERISTICS
MUTUAL CAPACITANCE, average
83+7 nF/mile
-
CAPACITANCE UNBALANCE: Pair to pair
Individual Maximum
80 pF/kft
145 pF/km
CAPACITANCE UNBALANCE: Pair to Ground
Maximum Individual
800 pF/kft
2625 pF/km
FEXT Far end CROSSTALK, dB/kft minimum Power Sum
@150 kHz
63
NEXT Near end CROSSTALK, dB/kft minimum Power Sum
@772 kHz
44
ATTENUATION @ 150 kHz @ 20°C, Maximum Individual
Nominal dB/kft
Nominal dB/km
HIGH VOLTAGE TEST, d-c kV for 3 seconds
Conductor to Conductor
Conductor to Shield
16
52+4 nF/km
11.0
6.8
5.0
20.0
D-c CONDUCTOR RESISTANCE @ 20°C, Maximum Individual
Ù/kft
Ù/km
RESISTANCE UNBALANCE
Maximum Individual
Maximum Average
5%
1.5%
INSULATION RESISTANCE, Minimum
MÙ · Mile
MÙ · km
1,000
1,600
17.4
57.1
II. Buried Wire
Buried Service Wire
(Non-shielded, non-armored, single jacket)
BSW USJ
62.BSWUSJ.01
CONDUCTORS:
Solid, annealed 22 AWG copper with a,
nominal diameter 0.0250” (0.634mm) or
24 AWG with a nominal diameter of 0.0201”
(0.511 mm)
CORE ASSEMBLY:
The core is filled with ETPR (80°C)
compound. Then covered with a nonhygroscopic tape with an overlap. A filling
compound is also applied over wrap.
INSULATION:
Solid, high-density, polyethylene or polypropylene in distinctive colors, according to
telephone industry standards.
OUTER JACKET:
Black, linear, low-density, high molecular
weight polyethylene, able to withstand
exposure to sunlight, ground humidity and
chemicals. Sequential footage (or meter)
markings are printed on the jacket at 2
foot (or 1 m) intervals.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths with a maximum length of 6.5”
(165 mm).
Service drop for telephony or underground installation in ducts.
ANSI/ICEA S-86-634-1991.
Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
ISO-9001 Quality Assurance System
On wooden reels that are lagged for additional protection.
Number
Of
Pairs
Nominal
OD
In
Mm
Cable Net Weight
Shipping Length
Approximate
Shipping Weight
Lbs
kft
Lbs/kft
kg/km
FT
m
2
-
-
-
-
-
-
-
-
4
0.33
8.3
47
70
5000
1520
292
132
6
0.37
9.5
64
95
1000 or
2500 or
5000
305 or
760 or
1520
112
215
373
51
98
169
Note: Values shown are nominal,
subject to manufacturing tolerances.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
17
II. Buried Wire
Buried Service Wire
(Non-shielded, non-armored, single jacket)
BSW USJ
62.BSWUSJ.01
Number
Of
Pairs
2
4
6
Nominal
OD
In
Mm
Cable Net Weight
Shipping Length
Lbs/kft
kg/km
FT
m
Approximate
Shipping Weight
Lbs
kg
-
-
-
-
-
-
-
-
0.28
7.2
32
48
1000
2500
5000
305
760
1520
80
136
217
36
62
98
0.37
9.5
64
95
1000 or
2500 or
5000
305 or
760 or
1520
112
215
373
51
98
169
Note: Values shown are nominal, subject to manufacturing tolerances.
22 AWG
MUTUAL CAPACITANCE, average
83+7 nF/mile
-
52+4 nF/km
CAPACITANCE UNBALANCE: Pair to pair
Maximum Individual
80 pF/kft
145 pF/km
CAPACITANCE UNBALANCE: Pair to Ground
Individual Maximum
800 pF/kft
2625 pF/km
FEXT Far end CROSSTALK, dB/kft minimum Power Sum
@150 kHz
63
NEXT Near end CROSSTALK, dB/kft minimum Power Sum
@772 kHz
44
ATTENUATION @ 150 kHz @ 20°C, Maximum Individual
Nominal dB/kft
Nominal dB/km
HIGH VOLTAGE TEST, d-c kV for 3 seconds
Conductor to Conductor
Conductor to Shield
D-c CONDUCTOR RESISTANCE @ 20°C, Maximum Individual
Ù/kft
Ù/km
RESISTANCE UNBALANCE
Maximum Individual
Maximum Average
INSULATION RESISTANCE, Minimum
MÙ · Mile
MÙ · km
18
24 AWG
11.0
6.8
14.0
87
5.0
10.0
4.0
10.0
17.4
57.1
27.5
902
5%
1.5%
1,000
1,600
AERIAL SERVICE WIRE
62.ASW.01
DESCRIPTION:
¥ Bare copper 22 AWG conductors
¥ Color coded to industry standards
¥ Sunlight-resistant PVC jacket
¥ Solid, high-density polyethylene insulation
¥ Galvanized steel messenger wire 2.11mm O.D. ¥ Packaging available in reels, cartons and coils
APPLICATIONS:
z Extending telephone circuits from a distribution terminal to a subscriber’s station protectors.
z Aerial applications.
PROPERTIES:
MECHANICAL PROPERTIES
Pair
Count
Conductor
Diameter
(mm)
Insulation
Diameter
(mm)
Overall
Diameter
(mm)
Net
Weight
(kg/km)
3
6
0.643
0.643
1.1
1.1
7 x 13
9 x 15
67
120
* Values shown are nominal, subject to manufacturing tolerances.
SPECIFICATIONS:
Bellcore: GR-492-CORE
Bellcore: TR-NWT-000122
UL Listed
Quality System, ISO-9000
ELECTRICAL PROPERTIES
c.d. Resistance DC Resistance
Mutual
Capacitance
of
Unbalance
Capacitance
Unbalance
Conductor
(Pair to Pair)
(ohm/km)
(nF/km)
(pF/km)
56.5
5% max.
55.9 avg
58.4 max. ind.
Insulation
Resistance
(Megaohs-km)
145 max.
1600 min
TRANSMISSION CHARACTERISTICS
Frequency
KHz
150
772
Attenuation
dB/km
NEXT
dB/km
16.7
44 min.
Condumex Wire and Cable
FEXT
dB/km
58 min.
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
8-04
19
O
OUTDOOR CABLES UP TO -40 C
ARMORED MACROTEL OPTICAL CABLE
69d90
SPECIFICATIONS:
GR-20-CORE
APPLICATION & PROPERTIES:
¥ Installation in ducts or trays.
¥ Protection against rodents.
¥ Weather resistant.
¥ 6 to 288 fibers.
¥ Alternate cable direction to enable branching.
¥ External jacket with high friction strength.
MECHANICAL PROPERTIES
Number
of
Fibers
6 to 72
84 to 216
228 to 288
Maximum
Installation Tension
N
Compression
N/cm
2700
440
Minimum Bend Radius
mm
unloaded
loaded
350
260
440
330
550
410
Operating
Temperature
O
C
-40 to +70
DESCRIPTION:
1. Dielectric central traction element.
2. Optical fibers in thermoplastic tubes (2
layers with 144 to 288 fibers).
3. Expandable tape as water protection.
DIMENSIONS
4. Fiberglass or aramid yarn as strength
element.
5. Non-hygroscopic tapes and wires.
6. Internal polyethylene jacket.
7. Corrugate steel armor.
8. External black polyethylene jacket.
Number
of Fibers
Fibers
per Tube
Weight
kg/km
Overall
Diameter
mm
6 to 36
48 to 72
84
96
108
120
132 to 216
228 to 288
6
12
12
12
12
12
12
12
163
195
251
251
310
310
371
371
15.7
17.2
19.4
19.4
21.4
21.4
24.2
24.2
1
8
7
5
3
¥Values shown are nominal, subject to
manufacturing tolerances.
Condumex Wire and Cable
6
2
4
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
20
O
OUTDOOR CABLES UP TO -40 C
DRY DIELECTRIC MACROTEL CABLE
69d96
SPECIFICATIONS:
Bellcore GR-20
APPLICATION & PROPERTIES:
¥ Installation in ducts or trays.
¥ Aerial, attached to an external
messenger.
¥ Weather resistant and resistance to
water penetration.
¥ No metal elements
¥ 6 to 288 fibers.
¥ Filling material only in slack tubes,
making splicing easy.
¥ Alternate cable direction to enable
branching.
¥ External jacket with high friction
strength.
MECHANICAL PROPERTIES
Number
Of
Fibers
6 to 36
48 to 72
84 to 144
156 to 216
Maximum
Installation Tension
N
Compression
N/cm
2700
220
Minimum Bend Radius
mm
unloaded
loaded
180
240
200
270
300
390
300
400
Operating
Temperature
O
C
-40 to +75
DESCRIPTION:
DIMENSIONS
Number
of Fibers
Fibers
per Tube
Weight
kg/km
Overall
Diameter
mm
2 to 36
48 to 73
84 to 96
108 to 120
132 to 144
156 to 216
228 to 288
6
12
12
12
12
12
12
110
135
180
230
280
305
460
¥ Values shown are nominal, subject to
manufacturing tolerances.
21
12.0
13.5
16.0
18.0
20.0
20.5
24.5
1.Dielectric central traction element.
2.Optical fibers in slack thermoplastic tubes.
3.Fiberglass or aramid yarn as strength element.
4.Expandable tape as water protection.
5.External medium-density polyethylene jacket.
5
1
4
2
3
O
OUTDOOR CABLES UP TO -40 C
DIELECTRIC DJ MACROTEL OPTICAL CABLE
69d97
SPECIFICATIONS:
GR-20-CORE
APPLICATION & PROPERTIES:
¥ Installation in ducts or trays.
¥ Aerial, attached to an additional
messenger.
¥ Weather resistant.
¥ No metal elements
¥ Double polyethylene jacket.
¥ 6 to 144 fibers.
¥ Alternate cable direction to enable
branching.
¥ External jacket with high friction
strength.
MECHANICAL PROPERTIES
Numbers
of
Fibers
6 to 72
84 to 144
Maximum
Installation Tension
N
Compression
N/cm
2700
220
Minimum Bend Radius
mm
unloaded
Loaded
240
320
300
400
Operating
Temperature
O
C
-40 to +70
DESCRIPTION:
1.Dielectric central traction element.
2.Optical fibers identified by color.
3.Filled thermoplastic tube.
4.Expandable tape as water protection.
5.Non-hygroscopic tape and wires.
6.Internal polyethylene jacket.
7.Fiberglass or aramid yarn as strength
element.
8.External black polyethylene jacket.
1
DIMENSIONS
Number
of Fibers
Fibers
per Tube
Weight
Kg/km
Overall
Diameter
8
mm
6 to 36
48 to 72
84
96
108
120
132
144
6
12
12
12
12
12
12
12
170
195
235
265
290
325
360
385
2
13.5
16
17
18
19
20
21
22
7
3
6
4
¥ Values shown are nominal, subject to
manufacturing tolerances.
Condumex Wire and Cable
5
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
22
O
OUTDOOR CABLES UP TO -40 C
DRY LIGHT ARMORED MACROTEL CABLE
69d99
SPECIFICATIONS:
Bellcore GR-20
APPLICATION & PROPERTIES:
¥ Installation in ducts or trays.
¥ Aerial, attached to an external
messenger.
¥ Weather resistant and resistance to
water penetration.
¥ Armor for protection against rodents.
¥ 6 to 288 fibers.
¥ Filling material in buffer tubes.
¥ Alternate cable direction to enable
branching.
¥ External jacket with high friction
strength.
MECHANICAL PROPERTIES
Number
of
Fibers
6 to 36
48 to 72
84 to 144
156 to 216
Maximum
Compression
Installation Tension
N/cm
N
2700
220
Minimum Bend Radius
mm
unloaded
loaded
260
200
290
220
420
310
430
320
Operating
Temperature
O
C
-40 to +75
DESCRIPTION:
1. Dielectric central traction element.
2. Optical fibers in thermoplastic tubes.
3. Fiberglass or aramid yarn as strength
element.
4.Expandable tape as water protection.
5.Corrugate steel armor.
6.External medium-density polyethylene
jacket.
DIMENSIONS
Number
of Fibers
Fibers
per Tube
Weight
kg/km
Overall
Diameter
3
2
mm
2 to 36
48 to 72
84 to 96
108 to 120
132 to 144
156 to 216
228 to 288
6
12
12
12
12
12
12
165
195
255
310
375
385
550
¥ Values shown are nominal, subject to
manufacturing tolerances.
23
13.5
15.0
17.0
19.0
21.0
21.5
25.5
1
6
4
5
RADIO FREQUENCY CABLES
1/2” (12.7mm) RF COAXIAL CABLE
68.RF.1/2
DESCRIPTION:
¥ Core conductor of copper coated aluminum
¥ Foamed polyethylene insulation with solid
polyethylene internal and external layer
¥ Corrugated copper external conductor
¥ Jacket of black polyethylene
APPLICATIONS:
z
Jumpers in microwave or cellular telephony systems
PROPERTIES:
¥ Low loss insulation
¥ High conductivity
¥ External corrugated conductor increases flexibility
¥ Available in specific lengths upon request, with or without connectors
MECHANICAL PROPERTIES
Core
Conductor
Diameter
Insulation
Diameter
Diameter
Over External
Conductor
Overall
Diameter
Minimum
Bend
Radius
Packaging
Standard
Lengths
Net
Weight
kg/km
4.8 mm
12.7 mm
14 mm
16 mm
125 mm
500 m
253
* Values shown are nominal, subject to manufacturing tolerances.
SPECIFICATIONS:
Quality System, ISO-9001.
MIL-C-28830
ELECTRICAL PROPERTIES
c.d. Resistance c.d. Resistance Characteristic Stationary
of Core
of External
Impedance Wave Ratio
Conductor
Conductor
VSWR
1.48 W/km
1.65 W/km
50 + 1W/km
1.2 minimum
Propagation Capacitance
Speed
88%
76 pF/m
Dielectric
Strength
4000 volts
ATTENUATION AND AVERAGE POWER
Frequency
MHz
10
50
150
300
500
800
960
Attenuation
dB/100 m
0.69
1.58
2.78
4.08
5.25
6.79
7.50
Condumex Wire and Cable
Average Power
kW
24.8
4.80
2.80
1.90
1.40
1.15
1.00
Frequency
MHz
1500
2000
3000
4000
5000
6000
8000
Attenuation
dB/100 m
9.60
11.2
14.3
16.6
19.5
21.8
26.0
Average Power
kW
0.80
0.70
0.55
0.45
0.40
0.35
0.30
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
24
RADIO FREQUENCY CABLES
7/8” (22.2mm) RF COAXIAL CABLE
68.RF.7/8
DESCRIPTION:
¥ Copper tube core conductor
¥ Foamed polyethylene insulation with solid
polyethylene internal and external layer
¥ Corrugated copper external conductor
¥ Jacket of black polyethylene
APPLICATIONS:
z Connection of antennas in microwave or cellular telephony systems.
PROPERTIES:
¥ Low loss insulation
¥ High conductivity
¥ External corrugated conductor increases flexibility
¥ Available in specific lengths upon request
MECHANICAL PROPERTIES
Core
Conductor
Diameter
Insulation
Diameter
Diameter
Over External
Conductor
Overall
Diameter
Minimum
Bend
Radius
Packaging
Standard
Lengths
Net
Weight
kg/km
9.02 mm
22.2 mm
24.8 mm
27.6 mm
250 mm
500 m
508
* Values shown are nominal, subject to manufacturing tolerances.
SPECIFICATIONS:
Quality System, ISO-9001.
MIL-C-28830
ELECTRICAL PROPERTIES
c.d. Resistance c.d. Resistance Characteristic Stationary
of Core
of External
Impedance Wave Ratio
Conductor
Conductor
VSWR
1.06 W/km
1.06 W/km
50 + 1W/km
1.2 minimum
Propagation Capacitance
Speed
89%
75 pF/m
Dielectric
Strength
6000 volts
ATTENUATION AND AVERAGE POWER
Frequency
MHz
10
50
150
300
400
500
700
25
Attenuation
dB/100 m
0.37
0.85
1.50
2.18
2.58
2.90
3.51
Average Power
kW
24.6
10.7
6.0
4.2
3.6
3.1
2.6
Frequency
MHz
800
960
1500
2000
3000
4000
5000
Attenuation
dB/100 m
3.79
4.20
5.46
6.47
8.32
9.93
11.5
Average Power
kW
3.79
2.1
1.7
1.4
1.1
0.9
0.8
RADIO FREQUENCY CABLES
1-1/4” (31.75mm) RF COAXIAL CABLE
68.RF.1-1/4
DESCRIPTION:
¥ Copper tube core conductor
¥ Foamed polyethylene insulation with solid
polyethylene internal and external layer
¥ Corrugated copper external conductor
¥ Jacket of black polyethylene
APPLICATIONS:
z Connection of antennas in microwave or cellular telephony systems.
PROPERTIES:
¥ Low loss insulation
¥ High conductivity
¥ External corrugated conductor increases flexibility
¥ Available in specific lengths upon request
MECHANICAL PROPERTIES
Core
Conductor
Diameter
Insulation
Diameter
Diameter
Over External
Conductor
Overall
Diameter
Minimum
Bend
Radius
Packaging
Standard
Lengths
Net
Weight
kg/km
13.1 mm
31.75 mm
34.7 mm
38.7 mm
380 mm
500 m
970
* Values shown are nominal, subject to manufacturing tolerances.
SPECIFICATIONS:
Quality System, ISO-9001.
MIL-C-28830
ELECTRICAL PROPERTIES
c.d. Resistance c.d. Resistance Characteristic Stationary
of Core
of External
Impedance Wave Ratio
Conductor
Conductor
VSWR
0.71 W/km
0.41 W/km
50 + 1W/km
1.2 minimum
Propagation Capacitance
Speed
89%
75 pF/m
Dielectric
Strength
10,000 volts
ATTENUATION AND AVERAGE POWER
Frequency
MHz
10
50
108
150
300
400
500
Attenuation
dB/100 m
0.28
0.63
0.94
1.12
1.62
1.89
2.15
Condumex Wire and Cable
Average Power
kW
36.9
16.1
10.8
9.1
6.3
5.3
4.7
Frequency
MHz
700
800
960
1250
1500
2000
3000
Attenuation
dB/100 m
2.58
2.79
3.09
3.60
4.02
4.76
6.08
Average Power
kW
3.9
3.6
3.3
2.8
2.5
2.1
1.7
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
26
RADIO FREQUENCY CABLES
1-5/8” (41.275mm) RF COAXIAL CABLE
68.RF.1-5/8
DESCRIPTION:
¥ Corrugated copper tube core conductor
¥ Foamed polyethylene insulation with solid
polyethylene internal and external layer
¥ Corrugated copper external conductor
¥ Jacket of black polyethylene
APPLICATIONS:
z Connection of antennas in microwave or cellular telephony systems.
PROPERTIES:
¥ Low loss insulation
¥ High conductivity
¥ External corrugated conductor increases flexibility
¥ Available in specific lengths upon request
MECHANICAL PROPERTIES
Core
Conductor
Diameter
Insulation
Diameter
Diameter
Over External
Conductor
Overall
Diameter
Minimum
Bend
Radius
Packaging
Standard
Lengths
Net
Weight
kg/km
17.3 mm
41.3 mm
46 mm
49.5 mm
510 mm
500 m
1170
* Values shown are nominal, subject to manufacturing tolerances.
SPECIFICATIONS:
Quality System, ISO-9001.
MIL-C-28830
ELECTRICAL PROPERTIES
c.d. Resistance c.d. Resistance Characteristic Stationary
of Core
of External
Impedance Wave Ratio
Conductor
Conductor
VSWR
0.67 W/km
0.32 W/km
50 + 1W/km
1.2 minimum
Propagation Capacitance
Speed
88%
75 pF/m
Dielectric
Strength
11,000 volts
ATTENUATION AND AVERAGE POWER
Frequency
MHz
10
50
108
150
300
500
700
27
Attenuation
dB/100 m
0.23
0.51
0.77
0.92
1.34
1.78
2.18
Average Power
kW
51.0
22.1
14.7
12.4
8.4
6.3
5.2
Frequency
MHz
800
960
1500
1700
2000
2300
2500
Attenuation
dB/100 m
2.35
2.62
3.43
3.71
4.09
4.47
4.72
Average Power
kW
4.8
4.3
3.3
3.1
2.7
2.5
2.4
TRUNK AND DISTRIBUTION CABLE
68.TR.02
AVAILABLE OPTIONS:
Self Supporting Cable with Messenger of 7 x 2 mm 750
Bare Cable 500 / 625 / 750
Self Supporting Cable with Messenger 2.77 mm 500 / 625
Jacketed Cable 500 / 625 / 750
Self Supporting Cable with Messenger of 7 x 1 mm 500 / 625 / 750
Flooded constructions are also available
PROPERTIES:
Cable
Type
Central
Conductor
Resistance
Aluminum
Tube
Resistance
Impedance
Capacitance
Ù/km
Ù/km
Ù
pF/m
%
4.4
2.76
1.87
1.24
0.75
0.62
75 + 2
50 + 3
87
500
625
750
Cable Central Cond. Insulation Aluminum
Overall Diameter Minimum Bend
Type
Diameter
Diameter Tube Diameter (With Jacket)
Radius
mm
mm
mm
mm
mm
500
2.77
11.43
12.70
14.3
625
3.48
14.30
15.88
17.4
750
4.24
17.22
19.05
21.0
100 (bare)
90 (jacketed)
127 (bare)
114 (jacketed)
180 (bare)
150 (jacketed)
In all cases, installation stress is 3,000 N with standard section lengths of 716 m.
Messenger
(Optional)
Messenger Type
Available for Style
Diameter of
Steel Messenger
Rupture Load
N
7 x 1 mm
7 x 2 mm
2.77 mm
500, 625, 750
750
500, 625
3.1 mm
6.2 mm
2.77 mm
7,600
29,500
8,000
Frequency 500
Mhz
5
0.5
30
1.3
55
1.8
108
2.5
150
2.9
183
3.3
250
3.9
300
4.3
400
5.0
500
5.7
600
6.3
750
7.1
1000
8.3
2
625
750
0.4
1.0
1.5
2.1
2.5
2.8
3.3
3.4
4.2
4.7
5.2
5.8
6.8
0.4
0.8
1.2
1.7
2.0
2.2
2.7
2.9
3.4
3.9
4.3
4.9
5.7
5
2
3
4. Polyethylene jacket (optional).
Condumex Wire and Cable
Attenuation [dB/100m]
1
2. Gas injected foam polyethylene insulation.
5. Steel messenger (figure 8 construction).
30
1
1. Central conductor made of copper clad aluminum.
3. Outer conductor, high-purity aluminum tube.
Velocity of
Propagation
3
4
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
28
Notes:
Condumex Wire and Cable
11-05
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
SOUTHWEST, INC.
3900 Dennis • Houston, Texas, 77004
(713)748-8200 • Fax: (713)748-4304
(800)725-9473
[email protected]
Grand• Prairie,
Texas
800-925-9473

Similar documents

4OSP Spec Sheet Set.cdr

4OSP Spec Sheet Set.cdr Corrugated, copolymer coated, 8-mil thick aluminum tape applied longitudinally with an overlap. The coating reduces the risk of shield corrosion. A flooding compound with adhesive properties is app...

More information

2014 FULL LINE CATALOG

2014 FULL LINE CATALOG NEW MODEL Tosin Abasi (Animals as Leaders) 8-STRING

More information