I. Exchange Cables Filled Solid ALPETH Cable REA/RUS PE-39 62.39.01 CONDUCTORS: Solid, annealed copper wires, in 26, 24, 22 and 19 AWG. INSULATION: Solid, high-density polyethylene or polypropylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths to minimize capacitance unbalance and crosstalk. CORE ASSEMBLY: In cables with 25 pairs or less, the pairs are laid forming a cylindrical shape. For larger cables, units of 25 pairs or superunits of 50 or 100 pairs are assembled to form the final core. The core is filled with ETPR (80°C) compound. Then covered with a non-hygroscopic tape with an overlap. A filling compound is applied over the wrap. All units and superunits are identified with color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and superunits are divided into 12 and 13 pair sub-units. SHIELD: Corrugated, copolymer coated, 8-mil thick aluminum tape applied longitudinally with an overlap. The coating reduces the risk of shield corrosion. A flooding compound with adhesive properties is applied over the shield. JACKET: Black, linear, low-density, high molecular weight polyethylene. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals. Outside plant telephony or underground installation. Meets REA/RUS PE-39 ANSI/ICEA S-84-608-1994. Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. Telecordia (Bellcore) equivalent: none ISO-9001 Quality Assurance System Packaged on wooden reels with a thermal wrap applied over the cable. The reels are also lagged for additional protection. Condumex Wire and Cable th 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473 7-04 1 26 AWG Product Code Number of Pairs In Nominal OD mm Approximate Cable Weight Lbs/kft Kg/km Standard Length Ft m 625152 625153 625154 625156 625157 625158 625159 625160 625161 625162 25 50 100 200 300 400 600 900 1200 1800 0.61 0.75 0.95 1.22 1.44 1.61 1.89 2.26 2.70 3.21 15.5 19.0 24.0 31.0 36.5 41.0 48.0 57.5 68.5 81.5 159 257 434 782 1114 1428 2927 2944 4003 5819 237 384 647 1166 1661 2129 3023 4390 5970 8678 5000 5000 3000 3000 3000 3000 1500 1000 1000 650 1525 1525 915 915 915 915 460 305 205 200 Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626168 626169 626170 626171 626172 626173 626174 626196 626177 626178 626179 626180 626181 6 12 18 25 50 75 100 200 300 400 600 900 1200 0.47 0.59 0.67 0.75 0.89 1.04 1.16 1.48 1.71 1.95 2.35 2.81 3.23 12.0 15.0 17.0 19.0 22.5 26.5 29.5 37.5 43.5 69.5 60.0 71.5 82.0 107 157 198 241 402 563 701 1261 1794 2260 3282 4727 5687 160 235 295 360 600 840 1045 1880 2675 3370 4895 7050 8481 5000 5000 5000 5000 5000 5000 3000 3000 3000 1650 1650 1000 650 1525 1525 1525 1525 1525 1525 915 915 915 500 500 305 200 Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626188 626189 626190 626191 626192 626193 626194 626196 626197 626198 626199 6 12 18 25 50 75 100 200 300 400 600 0.57 0.67 0.75 0.85 1.04 1.22 1.38 1.75 2.13 2.40 2.87 14.5 17.0 19.0 21.5 26.5 31.0 35.0 44.5 54.0 61.0 73.0 134 201 228 342 563 798 1019 1797 2625 3997 4976 200 300 340 510 840 1190 1520 2680 3915 5960 7420 5000 5000 5000 5000 3000 3000 3000 1650 1650 1000 1000 1525 1525 1525 1525 1525 915 915 500 500 305 305 Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626205 626206 626207 626208 626209 626210 626211 626213 626214 6 12 18 25 50 75 100 200 300 0.71 0.85 0.96 1.06 1.42 1.66 1.83 2.48 2.95 18.0 21.5 24.5 27.0 36.0 42.0 46.5 63.0 75.0 211 349 466 590 1059 1485 1921 3557 5197 315 520 695 880 1580 2215 2865 5305 7750 5000 5000 5000 5000 3000 3000 3000 1000 650 1525 1525 1525 1525 915 915 915 305 200 24 AWG Nominal OD Approximate Cable Weight Standard Length 22 AWG Nominal OD Approximate Cable Weight Standard Length 19 AWG 2 Nominal OD Approximate Cable Weight Standard Length Note: Values shown are nominal, subject to manufacturing tolerances. Special lengths are available upon request. I. Exchange Cables Filled Foam Skin ALPETH Cable REA/RUS PE-89 62.89.01 CONDUCTORS: Solid, annealed copper wires, in 26, 24, 22 AND 19 AWG. INSULATION: Expanded polyethylene (Foam Skin) with an external layer of solid, high-density polyethylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths to minimize capacitance unbalance and cross-talk. All units and superunits are identified with color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and super-units are divided into 12 and 13 pairs sub-units. SHIELD: Corrugated, copolymer coated, 8-mil thick aluminum tape applied longitudinally with an overlap. The coating reduces the risk of shield corrosion. A flooding compound with adhesive properties is applied over the shield. JACKET: Black, linear, low-density, high molecular weight polyethylene. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals. CORE ASSEMBLY: In cables with 25 pairs or less, the pairs are laid forming a cylindrical shape. For larger cables, units of 25 pairs or superunits of 50 or 100 pairs are assembled to form the final core. The core is filled with ETPR (80° C) compound. Then covered with a non-hygroscopic tape with an overlap. A filling compound is applied over the wrap. Outside plant telephony or underground installation. Meets REA/RUS PE-89 ANSI/ICEA S-84-608-1994. Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. Telecordia (Bellcore) equivalent: AN_A ISO-9001 Quality Assurance System Packaged on wooden reels with a thermal wrap applied over the cable. The reels are also lagged for additional protection. Condumex Wire and Cable th 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473 7-04 3 26 AWG Product Code Number of Pairs Nominal OD Approximate Cable Weight Standard Length In mm Lbs/kft Kg/km Ft m 626081 626082 626083 626084 626086 626087 626088 626089 626090 626091 626093 626095 25 50 75 100 200 300 400 600 900 1200 1800 2400 0.55 0.59 0.77 0.89 1.08 1.30 1.46 1.69 1.93 2.30 3.00 3.19 14.0 15.0 19.5 22.5 27.5 33.0 37.0 43.0 49.0 58.5 76.0 81.0 137 228 302 369 650 925 1153 1686 2411 3239 4764 6246 205 340 450 550 970 1380 1720 2515 3640 4830 7105 9315 4920 4920 4920 4920 4920 4920 3280 1640 1640 985 655 655 1500 1500 1500 1500 1500 1500 100 500 500 300 200 200 Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626101 626102 626103 626104 626105 626106 626107 626109 626110 626111 626112 626113 626114 6 12 18 25 50 75 100 200 300 400 600 900 1200 0.45 0.51 0.59 0.67 0.77 0.87 0.96 1.20 1.54 1.71 2.05 2.52 2.91 11.5 13.0 15.0 17.0 19.5 22.0 24.5 30.5 39.0 43.5 52.0 64.0 74.0 70 107 144 194 302 396 506 949 1368 1680 2515 3628 5123 105 160 215 290 450 590 755 1415 2040 2505 3750 5410 7460 4920 4920 4920 4920 4920 4920 4920 3280 3280 2950 1640 1640 655 1500 1500 1500 1500 1500 1500 1500 1000 1000 900 500 500 200 Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626120 626121 626122 626123 626124 626125 626126 626128 626129 626130 626131 626132 6 12 18 25 50 75 100 200 300 400 600 900 0.47 0.59 0.67 0.81 0.94 1.14 1.22 1.65 1.91 2.03 2.62 3.15 12.0 15.0 17.0 20.5 24.0 29.0 31.0 42.0 48.5 51.5 66.5 80.0 87 137 211 302 453 644 771 1482 2106 2602 4090 6025 130 205 315 450 675 960 1150 2210 3140 3880 6100 8985 4920 4920 4920 4920 4920 4920 4920 3280 1640 1640 985 655 1500 1500 1500 1500 1500 1500 1500 1000 500 500 300 200 Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626136 626137 626138 626139 626140 626141 626143 626144 626145 6 12 18 25 50 75 100 200 300 0.59 0.71 0.81 0.91 1.16 1.32 1.50 2.01 2.36 15.0 18.0 20.5 23.0 29.5 33.5 38.0 51.0 60.0 141 231 308 409 744 1063 1368 2635 3856 210 345 460 610 1110 1585 2040 3930 5750 4920 4920 4920 4920 3280 3280 1640 1640 985 1500 1500 1500 1500 1000 1000 500 500 300 24 AWG Nominal OD Approximate Cable Weight Standard Length 22 AWG Nominal OD Approximate Cable Weight Standard Length 19 AWG 4 Nominal OD Approximate Cable Weight Standard Length Note: Values shown are nominal, subject to manufacturing tolerances. Special lengths are available upon request. I. Exchange Cables Filled Foam Skin CACSP Cable REA/RUS PE-89 62.89.02 CONDUCTORS: Solid, annealed copper wires, in 26, 24, 22 and 19 AWG. INSULATION: Expanded polyethylene (Foam Skin) with an external layer of solid, high-density polyethylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths to minimize capacitance unbalance and cross-talk. CORE ASSEMBLY: In cables with 25 pairs or less, the pairs are laid forming a cylindrical shape. For larger cables, units of 25 pairs or superunits of 50 or 100 pairs are assembled to form the final core. The core is filled with ETPR (80°C) compound. Then covered with a non-hygroscopic tape with an overlap. Filling compound is also applied over the wrap. All units and superunits are identified with color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and superunits are divided into 12 and 13 pairs sub-units. SHIELD: Corrugated, copolymer coated aluminum tape, 8-mil thick applied longitudinally with a gap. A flooding compound is applied over the shield. ARMOR: Corrugated shield of copolymer coated steel tape, 6-mil thick. A flooding compound with adhesive properties is applied over the armor. JACKET: Black, linear, low-density, high molecular weight polyethylene. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals. Outside plant telephony, direct burial or underground installation. Meets REA/RUS PE-89 ANSI/ICEA S-84-608-1994. Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. Telecordia (Bellcore) equivalent: AN W ISO-9001 Quality Assurance System Condumex Wire and Cable th 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473 7-04 5 26 AWG Product Code Number of Pairs In Nominal OD mm Approximate Cable Weight Lbs/kft Kg/km Standard Length Ft m 626280 626281 626282 626283 626285 626286 626287 626288 626290 626292 626294 626296 25 50 75 100 200 300 400 600 900 1200 1800 2400 0.51 0.59 0.75 0.87 1.08 1.30 1.40 1.63 2.28 2.83 3.15 13.0 15.0 19.0 22.0 27.0 32.0 35.5 41.5 49.0 58.0 72.0 80.0 145.0 235 312 386 690 925 1156 1230 1740 2548 3382 4964 6256 215 350 465 574 1027 1436 1830 2589 3790 5032 7386 9309 4920 4920 4920 4920 4920 4920 3280 1640 1640 985 655 655 1500 1500 1500 1500 1500 1500 100 500 500 300 200 200 Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626300 626301 626302 626303 626304 626305 626306 626308 626309 626310 626311 626313 626315 6 12 18 25 50 75 100 200 300 400 600 900 1200 0.40 0.51 0.57 0.65 0.75 0.87 0.94 1.18 1.50 1.69 1.97 2.44 2.84 11.0 13.0 14.5 16.5 19.0 22.0 24.0 30.0 38.0 43.0 50.0 62.0 72.0 89 127 164 198 322 439 546 997 1383 1820 2615 3878 5163 132 189 244 295 480 653 812 1484 2058 2708 3891 5770 7683 4920 4920 4920 4920 4920 4920 4920 4920 3280 3280 2950 1640 1640 655 1500 1500 1500 1500 1500 1500 1500 1000 1000 900 500 500 Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626320 626321 626322 626323 626324 626325 626326 626328 626329 626330 626331 626333 6 12 18 25 50 75 100 200 300 400 600 900 0.47 0.59 0.67 0.77 0.91 1.06 1.22 1.54 1.77 2.03 2.50 3.03 12.0 15.0 17.0 19.5 23.0 27.0 31.0 39.0 45.0 51.5 63.5 77.0 104 167 221 287 478 644 831 1482 2106 2732 4090 6120 155 248 329 427 711 960 1237 2210 3140 4055 6100 9107 4920 4920 4920 4920 4920 4920 4920 3280 1640 1640 985 655 1500 1500 1500 1500 1500 1500 1500 1000 500 500 300 200 Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626340 626341 626342 626343 626344 626345 626346 626348 626349 6 12 18 25 50 75 100 200 300 0.59 0.71 0.85 0.91 1.16 1.32 1.50 2.01 2.36 15.0 18.0 21.5 23.0 29.5 33.5 38.0 51.0 60.0 141 231 308 409 744 1063 1368 2635 3856 210 345 460 610 1110 1585 2040 3930 5750 4920 4920 4920 4920 3280 3280 1640 1640 985 1500 1500 1500 1500 1000 1000 500 500 300 24 AWG Nominal OD Approximate Cable Weight Standard Length 22 AWG Nominal OD Approximate Cable Weight Standard Length 19 AWG 6 Nominal OD Approximate Cable Weight Standard Length Note: Values shown are nominal, subject to manufacturing tolerances. Special lengths are available upon request. I. Exchange Cables Aircore ALPETH Cable REA/RUS PE-22 62.22.01 CONDUCTORS: Solid, annealed copper wires, in 26, 24 22 and 19 AWG. In order to have a rounder shape and better electrical performance, all units and superunits are divided into 12 and 13 pairs sub-units. INSULATION: Solid, high-density polyethylene or polypropylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths to minimize capacitance unbalance and crosstalk. CORE ASSEMBLY: In cables with 25 pairs or less, the pairs are laid forming a cylindrical shape. For larger cables, units of 25 pairs or superunits of 50 or 100 pairs are assembled to form the final core. All units and superunits are identified with color coded, non-hygroscopic, non-wicking binders. SHIELD: Corrugated, copolymer coated, 8-mil thick aluminum tape applied longitudinally with an overlap. The coating reduces the risk of shield corrosion. JACKET: Black, linear, low-density, high molecular weight polyethylene. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals. Meets REA/RUS PE-22 ANSI/ICEA S-85-625-1996 Standard for Telecommunications Cable Air Core, Polyolefin Insulated, Copper Conductor. Telecordia (Bellcore) equivalent: BH A ISO-9001 Quality Assurance System Packaged on wooden reels with a thermal wrap applied over the cable. The reels are also lagged for additional protection. Condumex Wire and Cable th 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473 7-04 7 26 AWG Product Code Number of Pairs 626001 626002 626003 626004 626005 626006 626007 626008 626009 626010 626011 626012 626013 626014 626015 626016 626017 12 18 25 50 75 100 150 200 300 400 600 900 1200 1500 1800 2100 2400 In 0.45 0.47 0.51 0.63 0.71 0.77 0.89 1.01 1.14 1.39 1.54 1.85 2.13 2.34 2.56 2.74 2.93 Nominal OD Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626025 626026 626027 626028 626029 626030 626031 626032 626033 626034 626035 626036 626037 626038 626039 626040 6 12 18 25 50 75 100 150 200 300 400 600 900 1200 1500 1800 0.39 0.47 0.51 0.55 0.71 0.81 0.87 1.04 1.18 1.40 1.57 1.87 2.28 2.60 2.85 3.11 10.0 12.0 13.0 14.0 18.0 20.5 22.0 26.5 30.0 35.5 40.0 47.5 58.0 66.0 72.5 79.0 62 81 107 133 225 314 396 596 767 1114 1447 2120 3153 4120 5085 6052 93 121 160 199 336 468 591 889 1144 16961 2158 3162 4702 6145 7583 9026 4920 4920 4920 4920 4920 4920 4920 3940 3940 3940 2950 1970 985 985 985 655 1500 1500 1500 1500 1500 1500 1500 1200 1200 1200 900 600 300 300 300 200 Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626048 626049 626050 626051 626052 626053 626054 626055 626056 626057 626058 626059 6 12 18 25 50 75 100 150 200 300 400 600 0.43 0.52 0.55 0.63 0.79 0.91 1.04 1.22 1.38 1.63 1.87 2.32 11.0 13.0 14.0 16.0 20.0 23.0 26.5 31.0 35.0 41.5 47.5 59.0 76 115 148 190 329 460 607 895 1163 1688 2218 3292 114 171 221 284 490 686 905 1335 1734 2518 3308 4309 4920 4920 4920 4920 4920 4920 3940 3940 3940 2950 1970 985 1500 1500 1500 1500 1500 1500 1200 1200 1200 900 600 300 Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626065 626066 626067 626068 626069 626070 626071 626072 626073 6 12 18 25 50 75 100 150 200 0.55 0.67 0.77 0.85 1.12 1.28 1.50 1.81 2.07 14.0 17.0 19.5 21.5 28.5 32.5 38.0 46.0 52.5 125 198 268 347 636 899 1186 1768 2326 187 295 400 517 949 1341 768 2637 3469 4920 4920 4920 3280 3280 3280 1970 1970 1970 1500 1500 1500 1000 1000 1000 600 600 600 mm 11.5 12.0 13.0 16.0 18.0 19.5 22.5 25.5 29.0 33.0 39.3 47.0 54.0 59.5 65.0 69.5 74.5 Approximate Cable Weight Lbs/kft 72 87 106 167 224 280 405 529 749 968 1405 2055 2692 3319 3964 4579 5206 Kg/km 106 130 158 248 334 418 604 789 1113 1443 2095 3065 4014 4949 5912 6828 7763 Standard Length Ft 4920 4920 4920 4920 4920 4920 4920 3940 3940 3940 2950 1970 1310 985 985 985 985 m 1500 1500 1500 1500 1500 1500 1500 1200 1200 1200 900 600 400 300 300 300 300 24 AWG Nominal OD Approximate Cable Weight Standard Length 22 AWG Nominal OD Approximate Cable Weight Standard Length 19 AWG 8 Nominal OD Approximate Cable Weight Standard Length Note: Values shown are nominal, subject to manufacturing tolerances. Special lengths are available upon request. II. Buried Wire Double Jacketed Buried Distribution Wire (Gopher resistent) PE-86 62.86.01 CONDUCTORS: Solid, annealed 22 AWG copper with a nominal diameter of 0.0250” (0.634 mm) INNER JACKET Black, linear, low-density, high molecular weight polyethylene. INSULATION: Solid, high-density, polyethylene or polypropylene in distinctive colors, conforming to telephone industry standards. SHIELD: Corrugated, copper-clad alloy steel (0.005” thick) tape applied longitudinally with an overlap. A flooding compound is applied on both sides of the tape. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths, with a maximum length of 6.5” (165 mm). OUTER JACKET: Black, linear, low density, high molecular weight polyethylene. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals. CORE ASSEMBLY: The core is filled with ETPR (80°C) compound, then covered with a non-hygroscopic tape with an overlap. A filling compound is also applied over the wrap. Service drop for telephony, underground installation or direct burial. ANSI/ICEA S-86-634-1991 Standard for Telecommunications Cable Filled, Polyolefin Insulated, Cooper Conductor. Meets REA/RUS PE-86 (for 2 and 3 pair, 22 AWG when a bronze shield - BDW B or when a cooper clad steel armor - BDW G DJ is used) ISO-9001 Quality Assurance System Packaged on wooden reels that are lagged for additional protection. Condumex Wire and Cable th 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473 7-04 9 II. Buried Wire Double Jacketed Buried Distribution Wire (Gopher resistent) PE-86 62.86.01 MECHANICAL PROPERTIES Number Of Pairs Nominal OD In Mm Cable Net Weight Shipping Length Approximate Shipping Weight Lbs kg Lbs/kft kg/km FT m 2 0.40 10.3 94 140 2500 or 5000 760 or 1520 292 558 132 253 3 0.44 11.1 110 162 2500 or 5000 760 or 1520 329 633 149 287 6 0.51 12.9 149 222 1000 or 2500 or 5000 305 or 760 or 1520 206 435 873 93 197 396 Note: Values shown are nominal, subject to manufacturing tolerances. ELECTRICAL CHARACTERISTICS MUTUAL CAPACITANCE, average 83+7 nF/mile - CAPACITANCE UNBALANCE: Pair to pair Maximum Individual 80 pF/kft 145 pF/km CAPACITANCE UNBALANCE: Pair to Ground Individual Maximum 800 pF/kft 2625 pF/km FEXT Far end CROSSTALK, dB/kft minimum Power Sum @150 kHz 63 NEXT Near end CROSSTALK, dB/kft minimum Power Sum @772 kHz 44 ATTENUATION @ 150 kHz @ 20°C, Maximum Individual 10 52+4 nF/km Nominal dB/kft Nominal dB/km 11.0 6.8 HIGH VOLTAGE TEST, d-c kV for 3 seconds Conductor to Conductor Conductor to Shield 5.0 20.0 D-c CONDUCTOR RESISTANCE @ 20°C, Maximum Individual Ù/kft Ù/km RESISTANCE UNBALANCE Maximum Individual Maximum Average 5% 1.5% INSULATION RESISTANCE, Minimum MÙ · Mile MÙ · km 1,000 1,600 17.4 57.1 I. Exchange Cables Filled ASP Cable, Foam Skin Insulation AN_W Telecordia (Bellcore) 62.AN_W.01 DESCRIPTION: CONDUCTORS: Solid, annealed copper wires, in 26, 24, 22 and 19 AWG. INSULATION: Expanded polyethylene (Foam Skin) with an external layer of solid, high-density polyethylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths to minimize capacitance unbalance and cross-talk. CORE ASSEMBLY: In cables with 25 pairs or less, the pairs are laid forming a cylindrical shape. For larger cables, units of 25 pairs or superunits of 50 or 100 pairs are assembled to form the final core. The core is filled with ETPR (80°C) compound. Then covered with a non-hygroscopic tape with an overlap. Filling compound is also applied over the wrap. All units and superunits are identified with color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and super-units are divided into 12 and 13 pair sub-units. SHIELD: Corrugated, bare aluminum tape, 8-mil thick applied longitudinally with an overlap. A flooding compound with adhesive properties is applied over the shield. ARMOR: A corrugated shield of steel tape, 6-mil thick. JACKET Black, linear, low-density, high molecular weight polyethylene. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals. APPLICATION: Outside plant telephony, direct burial or underground installation. REFERENCE SPECIFICATIONS: Telecordia (Bellcore) TR-NWT-00421/3. ANSI/ICEA 84-608-1988 Generic Requirements for metallic telecommunication cables. CERTIFICATION: ISO-9001 Quality Assurance System PACKAGING: Packaged on wooden reels with a thermal wrap applied over the cable. The reels are also lagged for additional protection. Condumex Wire and Cable th 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473 7-04 11 26 AWG ANTW Product Code Number of Pairs In Nominal OD mm Approximate Cable Weight Lbs/kft Kg/km Standard Length Ft m 626220 626221 626223 626225 626226 626227 626228 626229 626230 626231 626232 25 50 100 200 300 400 600 900 1200 1800 2400 0.63 0.79 0.94 1.22 1.36 1.54 1.75 2.07 2.60 2.89 3.27 16.0 20.0 24.0 31.0 34.5 39.0 44.5 52.5 66.0 73.5 83.0 170 260 395 724 972 1240 1608 2513 3652 4256 6231 255 385 590 1080 1450 1850 2400 3750 5450 6350 9300 5900 5900 5900 5900 3940 3940 2950 1970 1475 985 820 1800 1800 1800 1800 1200 1200 900 600 450 300 250 Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626238 626239 626241 626243 626244 626245 626246 626247 626248 626250 25 75 100 200 300 400 600 900 1200 1800 0.73 0.87 1.04 1.36 1.57 1.81 2.11 2.56 2.99 3.56 18.5 22.0 26.5 34.5 40.0 46.0 53.5 65.0 76.0 90.5 241 349 550 972 1408 1864 2548 3805 5076 7631 360 520 820 1450 2100 2780 3800 5675 7570 11,380 5900 5900 5900 3940 3940 3280 2950 1475 1475 655 1800 1800 1800 1200 1200 1000 900 450 450 200 24 AWG Nominal OD Approximate Cable Weight Standard Length 22 AWG Product Code Number of Pairs 626250 626251 626252 626254 626255 626256 626257 626258 25 50 100 200 300 400 600 900 In 0.85 1.02 1.26 1.57 1.93 2.20 2.66 3.19 Nominal OD Product Code Number of Pairs In mm Lbs/kft Kg/km Ft m 626265 626266 626267 626268 626270 626271 626272 25 50 75 100 200 300 400 1.02 1.22 1.42 1.52 2.13 2.54 2.87 26.0 31.0 36.0 38.5 54.0 64.5 73.0 532 896 1228 1498 2895 4168 5423 793 1336 1832 2234 4318 6216 8088 4920 3280 3280 3280 1640 985 655 1500 1000 1000 1000 500 300 200 mm 21.5 26.0 32.0 42.5 49.0 56.0 67.5 81.0 Approximate Cable Weight Lbs/kft 322 489 831 1408 2045 2749 3856 5633 Kg/km 480 730 1240 2100 3050 4100 5750 8400 Standard Length Ft 5900 5900 3740 2950 2950 1970 1475 820 m 1800 1800 1200 900 900 600 450 250 19 AWG ANBW 12 Nominal OD Approximate Cable Weight Standard Length Note: Values shown are nominal, subject to manufacturing tolerances. Special lengths are available upon request. II. Buried Wire Buried Service Wire (Aluminium shield, single jacket) BSW A 62.BSW.01 CONDUCTORS: Solid, annealed 22 AWG copper with a nominal diameter 0.0250” (0.634mm) INSULATION: Solid, high-density, polyethylene or polypropylene in distinctive colors, conforming to telephone industry standards. SHIELD: Smooth, copolymer coated, 8-mil thick aluminum tape applied longitudinally with an overlap. The coating reduces the risk of shield corrosion. A flooding compound with adhesive properties is applied over the shield. JACKET: Black, linear, low-density, high molecular weight polyethylene, able to withstand exposure to sunlight, ground humidity and chemicals. Sequential footage (or meters) markings are printed on the jacket at 2 foot (or 1 m) intervals. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths, with a maximum length of 6.5” (165 mm). CORE ASSEMBLY: The core is filled with ETPR (80°C) compound. Then covered with a nonhygroscopic tape with an overlap. A filling compound is also applied over the wrap. Service drop for telephony, underground installation or in ducts. ANSI/ICEA S-86-634-1991 Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. ISO-9001 Quality Assurance System Packaged on wooden reels that are lagged for additional protection Condumex Wire and Cable th 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473 7-04 13 II. Buried Wire Buried Service Wire (Aluminium shield, single jacket) BSW A 62.BSW.01 Number Of Pairs Nominal OD In Mm Cable Net Weight Shipping Length Approximate Shipping Weight Lbs kg Lbs/kft kg/km FT m 2 0.29 7.4 39 58 2500 762 139 63 3 0.32 8.2 48 72 2500 762 164 75 Note: Values shown are nominal, subject to manufacturing tolerances. MUTUAL CAPACITANCE, average 83+7 nF/mile - CAPACITANCE UNBALANCE: Pair to pair Maximum Individual 80 pF/kft 145 pF/km CAPACITANCE UNBALANCE: Pair to Ground Individual Maximum 800 pF/kft 2625 pF/km FEXT Far end CROSSTALK, dB/kft minimum Power Sum @150 kHz 63 NEXT Near end CROSSTALK, dB/kft minimum Power Sum @772 kHz 44 ATTENUATION @ 150 kHz @ 20°C, Maximum Individual Nominal dB/kft Nominal dB/km HIGH VOLTAGE TEST, d-c kV for 3 seconds Conductor to Conductor Conductor to Shield 14 52+4 nF/km 11.0 6.8 5.0 10.0 D-c CONDUCTOR RESISTANCE @ 20°C, Maximum Individual Ù/kft Ù/km RESISTANCE UNBALANCE Maximum Individual Maximum Average 5% 1.5% INSULATION RESISTANCE, Minimum MÙ · Mile MÙ · km 1,000 1,600 17.4 57.1 II. Buried Wire Double Jacketed Buried Distribution Wire (Aluminium shield, double polyethylene jacket) BDW A 62.BDW_A.01 DESCRIPTION: CONDUCTORS: Solid, annealed 22 AWG copper with a nominal diameter of 0.0250” (0.634mm) INNER JACKET Black, linear, low-density, high molecular weight polyethylene. INSULATION: Solid, high-density, polyethylene or polypropylene in distinctive colors, conforming to telephone industry standards. SHIELD: Smooth, copolymer coated, 8-mil thick aluminum tape applied longitudinally with an overlap. The coating reduces the risk of shield corrosion. A flooding compound with adhesive properties is applied over the shield. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths, with maximum length of 6.5” (165 mm). JACKET: Black, linear, low-density, high molecular weight polyethylene, able to withstand exposure to sunlight, ground humidity and chemicals. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals. CORE ASSEMBLY: The core is filled with ETPR (80°C) compound. Then covered with a nonhygroscopic tape with an overlap. A filling compound is also applied over the wrap. APPLICATION: Service drop for telephony, underground installation. REFERENCE SPECIFICATIONS: ANSI/ICEA S-86-634-1991 Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. CERTIFICATION: ISO-9001 Quality Assurance System PACKAGING: Packaged on wooden reels that are lagged for additional protection. Condumex Wire and Cable th 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473 7-04 15 II. Buried Wire Double Jacketed Buried Distribution Wire (Aluminium shield, double polyethylene jacket) BDW A 62.BDW_A.01 MECHANICAL PROPERTIES Number Of Pairs Nominal OD In Mm Cable Net Weight Shipping Length Approximate Shipping Weight Lbs kg Lbs/kft kg/km FT m 2 0.35 8.9 52 62 2500 762 183 83 3 0.38 9.7 63 75 5000 1524 375 170 6 0.46 11.6 94 107 1000 305 148 67 Note: Values shown are nominal, subject to manufacturing tolerances. ELECTRICAL CHARACTERISTICS MUTUAL CAPACITANCE, average 83+7 nF/mile - CAPACITANCE UNBALANCE: Pair to pair Individual Maximum 80 pF/kft 145 pF/km CAPACITANCE UNBALANCE: Pair to Ground Maximum Individual 800 pF/kft 2625 pF/km FEXT Far end CROSSTALK, dB/kft minimum Power Sum @150 kHz 63 NEXT Near end CROSSTALK, dB/kft minimum Power Sum @772 kHz 44 ATTENUATION @ 150 kHz @ 20°C, Maximum Individual Nominal dB/kft Nominal dB/km HIGH VOLTAGE TEST, d-c kV for 3 seconds Conductor to Conductor Conductor to Shield 16 52+4 nF/km 11.0 6.8 5.0 20.0 D-c CONDUCTOR RESISTANCE @ 20°C, Maximum Individual Ù/kft Ù/km RESISTANCE UNBALANCE Maximum Individual Maximum Average 5% 1.5% INSULATION RESISTANCE, Minimum MÙ · Mile MÙ · km 1,000 1,600 17.4 57.1 II. Buried Wire Buried Service Wire (Non-shielded, non-armored, single jacket) BSW USJ 62.BSWUSJ.01 CONDUCTORS: Solid, annealed 22 AWG copper with a, nominal diameter 0.0250” (0.634mm) or 24 AWG with a nominal diameter of 0.0201” (0.511 mm) CORE ASSEMBLY: The core is filled with ETPR (80°C) compound. Then covered with a nonhygroscopic tape with an overlap. A filling compound is also applied over wrap. INSULATION: Solid, high-density, polyethylene or polypropylene in distinctive colors, according to telephone industry standards. OUTER JACKET: Black, linear, low-density, high molecular weight polyethylene, able to withstand exposure to sunlight, ground humidity and chemicals. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths with a maximum length of 6.5” (165 mm). Service drop for telephony or underground installation in ducts. ANSI/ICEA S-86-634-1991. Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. ISO-9001 Quality Assurance System On wooden reels that are lagged for additional protection. Number Of Pairs Nominal OD In Mm Cable Net Weight Shipping Length Approximate Shipping Weight Lbs kft Lbs/kft kg/km FT m 2 - - - - - - - - 4 0.33 8.3 47 70 5000 1520 292 132 6 0.37 9.5 64 95 1000 or 2500 or 5000 305 or 760 or 1520 112 215 373 51 98 169 Note: Values shown are nominal, subject to manufacturing tolerances. Condumex Wire and Cable th 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473 7-04 17 II. Buried Wire Buried Service Wire (Non-shielded, non-armored, single jacket) BSW USJ 62.BSWUSJ.01 Number Of Pairs 2 4 6 Nominal OD In Mm Cable Net Weight Shipping Length Lbs/kft kg/km FT m Approximate Shipping Weight Lbs kg - - - - - - - - 0.28 7.2 32 48 1000 2500 5000 305 760 1520 80 136 217 36 62 98 0.37 9.5 64 95 1000 or 2500 or 5000 305 or 760 or 1520 112 215 373 51 98 169 Note: Values shown are nominal, subject to manufacturing tolerances. 22 AWG MUTUAL CAPACITANCE, average 83+7 nF/mile - 52+4 nF/km CAPACITANCE UNBALANCE: Pair to pair Maximum Individual 80 pF/kft 145 pF/km CAPACITANCE UNBALANCE: Pair to Ground Individual Maximum 800 pF/kft 2625 pF/km FEXT Far end CROSSTALK, dB/kft minimum Power Sum @150 kHz 63 NEXT Near end CROSSTALK, dB/kft minimum Power Sum @772 kHz 44 ATTENUATION @ 150 kHz @ 20°C, Maximum Individual Nominal dB/kft Nominal dB/km HIGH VOLTAGE TEST, d-c kV for 3 seconds Conductor to Conductor Conductor to Shield D-c CONDUCTOR RESISTANCE @ 20°C, Maximum Individual Ù/kft Ù/km RESISTANCE UNBALANCE Maximum Individual Maximum Average INSULATION RESISTANCE, Minimum MÙ · Mile MÙ · km 18 24 AWG 11.0 6.8 14.0 87 5.0 10.0 4.0 10.0 17.4 57.1 27.5 902 5% 1.5% 1,000 1,600 AERIAL SERVICE WIRE 62.ASW.01 DESCRIPTION: ¥ Bare copper 22 AWG conductors ¥ Color coded to industry standards ¥ Sunlight-resistant PVC jacket ¥ Solid, high-density polyethylene insulation ¥ Galvanized steel messenger wire 2.11mm O.D. ¥ Packaging available in reels, cartons and coils APPLICATIONS: z Extending telephone circuits from a distribution terminal to a subscriber’s station protectors. z Aerial applications. PROPERTIES: MECHANICAL PROPERTIES Pair Count Conductor Diameter (mm) Insulation Diameter (mm) Overall Diameter (mm) Net Weight (kg/km) 3 6 0.643 0.643 1.1 1.1 7 x 13 9 x 15 67 120 * Values shown are nominal, subject to manufacturing tolerances. SPECIFICATIONS: Bellcore: GR-492-CORE Bellcore: TR-NWT-000122 UL Listed Quality System, ISO-9000 ELECTRICAL PROPERTIES c.d. Resistance DC Resistance Mutual Capacitance of Unbalance Capacitance Unbalance Conductor (Pair to Pair) (ohm/km) (nF/km) (pF/km) 56.5 5% max. 55.9 avg 58.4 max. ind. Insulation Resistance (Megaohs-km) 145 max. 1600 min TRANSMISSION CHARACTERISTICS Frequency KHz 150 772 Attenuation dB/km NEXT dB/km 16.7 44 min. Condumex Wire and Cable FEXT dB/km 58 min. th 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473 8-04 19
Similar documents
Outside Plant
Corrugated, copolymer coated, 8-mil thick aluminum tape applied longitudinally with an overlap. The coating reduces the risk of shield corrosion. A flooding compound with adhesive properties is app...
More information58 for more information visit www.Ibanez.com for more
The universally-praised EW Series is our original blend of exotic tone woods with a B-Band® UST™ pickup, an Ibanez SRTc preamp with chorus and onboard tuners, all adding up to a show-stealing instr...
More information