PLL LED Lamp
Transcription
PLL LED Lamp
S- type PLL LED Lamp - Hight Voltage PLL LED Lamp Non-dimmable 410mm Base Type : 2G11 Input Voltage : H:100~240V LED Source : Nichia / Epistar 3020 410mm-Beam Angle : 120° 533/560mm-Beam Angle : 115° Total Power Consumption : 21W±10% 533mm Safety & Environment Specifications S-Type-PLL LED Lamp Light bulbs are manufactured to conform to the following safety approbation. REACH Certificated Mark Certificate Approval ● ● ● ● Certificate Approval : ● : Completed : In Progress Rev:01 201506 B.L.T.C. RESERVES ALL RIGHTS |www.bltc.com.tw 1 Specification Polar Diagram No. Part Number LED Source Input Voltage Typical Power C.R.I. Beam Angle (°) CBCP Candela (cd) Total Pow. (RA) 2700K 80 120 500 21 1525 73 NO 0.9 3000K 80 120 545 21 1660 79 NO 0.9 5000K 70 120 600 21 1825 87 NO 0.9 650 21 1980 94 NO 0.9 21 1950 93 NO 0.9 21 2125 101 NO 0.9 M2340 EN 111 NO 0.9 121 NO 0.9 CCT Lumens +/-10% (lm) Efficiency (lm/W) Dimming Factor H1 410mm 1 BLS4102G11CC-NVW12005H N-157 2 BLS4102G11CC-NWW12005H N-157 3 BLS4102G11CC-NCW12005H N-157 4 BLS4102G11CC-NW12005H N-157 5700K 70 120 5 BLS4102G11CC-OVW12005H EPISTAR 3020 2700K 80 120 6 BLS4102G11CC-OWW12005H EPISTAR 3020 3000K 80 7 BLS4102G11CC-ONW12005H EPISTAR 3020 4000K 80 8 BLS4102G11CC-OW12005H EPISTAR 3020 5700K 70 120 2700K 80 115 545 21 1840 88 NO 0.9 3000K 80 115 590 21 1995 95 NO 0.9 5000K 70 115 645 21 2175 104 NO 0.9 Universal 100-240V Universal 100-240V 120UNDER 120 MEA S21 URE 21 T 2535 533mm 9 BLS5332G11CC-NVW14405H N-157 10 BLS5332G11CC-NWW14405H N-157 11 BLS5332G11CC-NCW14405H N-157 12 BLS5332G11CC-NW14405H N-157 5700K 70 115 710 21 2395 114 NO 0.9 13 BLS5332G11CC-OVW14405H EPISTAR 3020 2700K 80 115 545 21 1840 88 NO 0.9 14 BLS5332G11CC-OWW14405H EPISTAR 3020 3000K 80 115 590 21 1995 95 NO 0.9 15 BLS5332G11CC-ONW14405H EPISTAR 3020 4000K 80 115 645 21 2175 104 NO 0.9 16 BLS5332G11CC-OW14405H EPISTAR 3020 5700K 70 115 710 21 2395 114 NO 0.9 2700K 80 110 490 21 1840 88 NO 0.9 3000K 80 110 540 21 1995 95 NO 0.9 5000K 70 110 590 21 2175 104 NO 0.9 Universal 100-240V Universal 100-240V 560mm 17 BLS5602G11CC-NVW16805H N-157 18 BLS5602G11CC-NWW16805H N-157 19 BLS5602G11CC-NCW16805H N-157 20 BLS5602G11CC-NW16805H N-157 5700K 70 110 640 21 2395 114 NO 0.9 21 BLS5602G11CC-OVW16805H EPISTAR 3020 2700K 80 115 625 21 1930 92 NO 0.9 22 BLS5602G11CC-OWW16805H EPISTAR 3020 3000K 80 115 690 21 2125 101 NO 0.9 23 BLS5602G11CC-ONW16805H EPISTAR 3020 4000K 80 115 653 21 1315 63 NO 0.9 24 BLS5602G11CC-OW16805H EPISTAR 3020 5700K 70 115 815 21 2510 120 NO 0.9 Universal 100-240V Universal 100-240V Option 1 : Lamp base: 2G11 Option 2 : Input voltage H:100~240V Option 3 : The above CCT. is defined based on ANSI standard. Specific color temperature can be done upon customer request. For instance 2700K could be assigned as 2580~2725K or 2725~2870K, the same can be accomplished for 3500K and 5500K as well but shall be with different price.2200K is also available upon request.2200K is also available upon request. Option 4 : 4700~6700K typical CRI +70; 2580~4500K typical CRI +80; CRI+90 is also available upon request. Certificate Approval : RoHS COMPLIANT 45TH S TYPE PLL LED Lamp Rev:01 201506 B.L.T.C. RESERVES ALL RIGHTS |www.bltc.com.tw 2 2D Drawing Product Packing PLL LED Step 1 Step 2 Gife Box/ White Box 1Pc of Lamp Dimensions(mm) L:445*W:70*H:46 L:573/600*W:70*H:46 Step 3 Inner Carton 5 Boxes Dimensions(mm) L:465*W:250*H:90 L:583/610*W:250*H:85 Lamp body material Outer Carton 2 Inner Cartons (10 White Boxes) Dimensions(mm) L:485*W:270*H:200 L:603/630*W:270*H:195 Dimension (mm) Ø: Net Weight (g) 24 23 42 43 COVER : PC 410 PLASTIC HOUSING : PC 417 BASE : NPB 43 42 533 540 43 42 560 567 No sealed fixtures Base 2G11 Not for outdoor fixtures Net Weight (g) Luminaire Notice The LED Lamp is not compatible with all luminaires for halogen lamps. Before installation, please read following guidelines: -No sealed fixtures. -Not for outdoor fixtures. -Not for wet environment. -Not for integral primary optics. Live and Neutral Wire pin will be soldered. L(Live Wire) N(Neutral Wire) 2G11 S TYPE PLL LED Lamp Rev:01 201506 B.L.T.C. RESERVES ALL RIGHTS |www.bltc.com.tw 3 Installation Procedure: To be Carried Out by a Qualified Person 1) Ensure that mains supply is switched off before installation, maintenance or lamp replacement. 2) Where applicable, remove diffuser, existing lamp(s) and starter. 3) Remove/bypass existing ballast and connect Live and Neutral. 4) Insert the BLTC LED Lamp. 5) Ensure all screws/clips are secured, wiring is safely protected and diffusers replaced before switching on power. Tradition power LED Ballest Tradition power Ballest LED power power Ballest Ballest Safety Label & Warning • • • • • • • • • • • • • • o not cover lamp with paper, fabric, or any flammable material to avoid burning. D Working Environmental Temperature: -20 ~ +40° Do not insert metal objects into the gap of lamp base. The appropriate combination of lamp and lamp base should be carefully selected for different voltage and wattage. Do not use in high-humidity environment or near water to avoid damage. (Except B.L.T.C. Outdoor IP65 version) Not suitable for use in automatic light sensor system, emergency lighting fixture and mercury fixture to avoid damage and burning. Do not use near flammable objects such as gasoline, spray, chemicals, paints, oil…etc. Do not use in place that is likely to be impacted by force or vibration. Do not use in acidic environment. Please turn the light off when installing or cleaning to avoid electrical shock. Please handle with care to avoid damage and collision. Do not touch any powered-on lamps or lamps that have just been turned off to avoid burning. Please ensure the lamp is tightly installed into the socket to avoid dropping. Please select the appropriate fixture based on lamp size and weight. General Guideline • • • • • • • • • • • • Slight difference of color temperature and brightness is likely to occur for the same part number due to the difference of LED chips. Brightness, color temperature, and light distribution may vary with different types of bulbs. To avoid heat build-up and the shortening of product lifetime, sealed fixture is not recommended. Keep the lamp away from radio, video and television for a distance of 1 meter to avoid noise caused by interference. Do not install lamp in heal insulated fixture. Do not disassemble or reconstruct the lamp. Do not stare directly at the lamp to avoid eye injury. The light distribution may vary with different type of fixtures. Do not wash the lamp with water. Do not use the lamp outdoor if it is not marked as IP65. To avoid damage and poor insulation, do not use the lamp near water or in frosted environment if it is not marked as IP65. For lamps with a weight significantly higher than that of the lamps for which they are a replacement, attention should be drawn to the fact that the increased weight may reduce the mechanical stability of certain luminaires and lampholders and may impair contact making and lamp retention. S TYPE PLL LED Lamp Rev:01 201506 B.L.T.C. RESERVES ALL RIGHTS |www.bltc.com.tw 4