Whole Home Dehumidifier
Transcription
Whole Home Dehumidifier
INDOOR AIR QUALITY CCWH Complete Comfort™ Whole-Home Dehumidifier Bulletin No. CCWH (08/2011) E N G I N E E R I N G D ATA CCWH-090 CCWH-135 CCWH-065 ENERGY STAR® Rating for CCWH-065 Model Only Nominal Capacity - 65 to 135 pints per day Model Number Identification CCWH - 090 Unit Type CCWH = Complete Comfort Whole Home Dehumidifier Nominal Capacity 065 = 65 pints per day 090 = 90 pints per day 135 = 135 pints per day FEATURES Contents Dimensions..................................................................10 Features........................................................................1 Installation Clearances................................................11 Model Number Identification..........................................1 Optional Accessories.....................................................4 Performance..................................................................5 Sizing Guidelines...........................................................8 Specifications................................................................4 Typical Applications.......................................................9 WARRANTY All covered components − Limited five year warranty in residential applications, one year in non-residential applications. Refer to Equipment Limited Warranty certificate included with equipment for details. APPROVALS All units are E.T.L. Listed. Energy Star® certified unit (CCWH-065 model only) is designed to use less energy, help save money on utility bills, and help protect the environment. APPLICATIONS The Complete Comfort™ Whole Home Dehumidifier is designed to control humidity throughout the home or in specific locations such as an attic or basement. Also used for air cycling and ventilation control. CCWH-090 and CCWH-135 models are equipped with a humidity sensor that automatically and continually measures the relative humidity. Based on that measurement, the unit will operate to control the humidity based on the set point. CCWH-090 and CCWH-135 models feature a built-in, automatic air cycling feature can be utilized to activate the furnace/air handler blower to cycle air throughout the whole home for proper balance and comfort. CCWH-090 and CCWH-135 models feature a patented, built-in ventilation feature allows fresh air to be brought into the home from the outside. The dehumidifier will condition the incoming air, if needed. FEATURES Filter Includes washable, MERV 8 (Minimum Efficiency Reporting Value) filter. Blower CCWH-065 Model Blower assembly is a UL approved impeller type with backward curved centrifugal fan equipped with maintenance free ball bearings. CCWH-090-135 Models Blower assembly includes shaded-pole, heavy-duty, direct drive blower and blower wheel. Operates during both ventilation and dehumidification modes. Compressor R-410A, rotary-type compressor. Cabinet Constructed of 22 gauge, pre-painted steel. Interior is lined with 1 in., foil-faced, expanded polystyrene to eliminate noise, condensation and air loss. Duct start collars are included. CCWH-065 only - Supply collar can be relocated from the end of the cabinet to the top if space is restricted The supply outlet is equipped with a built-in backflow damper. Adjustable feet (-065 model up to 4 in., -090-135 models - up to 3 in.) to level unit. If the dehumidifier is installed in an attic or location requiring leak protection, the unit should be placed in a secondary condensate drain pan with a normally closed condensate overflow safety switch (float switch). CCWH Complete Comfort Whole-Home Dehumidifier / Page 2 Controls CCWH-065 Model Dehumidistat is furnished and factory installed on the unit cabinet inlet panel. It can be easily removed for relocation to another area within the living space. The dehumidistat continually measures the humidity in the air to control the dryness level set on the dial. Terminal strip for connections of HVAC equipment, furnace or air handler and float switch. When connected to HVAC equipment the dehumidifier automatically controls indoor blower operation during dehumidification operation. Two on-board LED’s provides instant status of operation and maintenance required. Power is applied to system - Green Service Required - Red Three internal, amber LED’s provide status of dehumidifier impeller (DEH), compressor (COMPR) and indoor unit blower (HVAC) (if applicable). Viewable when the dehumidifier cover is removed. CCWH-090-135 Models Factory installed control handles operation of unit. Terminal strip for connections of furnace/air handler, float switch, ventilation dampers, outdoor air sensor, and optional Whole-Home Dehumidistat. DIP switches are used to configure system set (whole house, zoned or combination system) and ventilation times (30, 60, 90 or 120 minutes). DIP switches are used to configure ventilation cycle periods (1/2, 1, 2, or 3 hours) and a knob for configuring cycle times (from 0 to 60 minutes). Knob on the front of the unit sets the desired humidity level. On-board humidity sensing allows for better whole home monitoring and control of humidity. Optional remote Whole-Home Dehumidistat can be used to provide easy humidity control accessibility. On-board LED provides instant status of operation and maintenance required. Normal Operation – Green Air Sampling or Defrosting – Flashing Green Service Required – Flashing Red When equipped with overflow safety switch (field provided and installed), the dehumidifier will continue to ventilate but the compressor is disabled when the switch is open. FEATURES REQUIRED COMPONENTS (-065 MODEL ONLY) Drain Pan Required if unit is installed in an attic or location requiring leak protection. (-090, -135 MODELS ONLY) Backflow Damper Constructed of rolled galvanized steel with stiffening ribs to maintain rigidity. A single steel offset blade is attached to a one piece aluminium shaft connected with nylon bearings for smooth operation. Spring return, normally closed, power open. Requires 24V transformer ordered separately. Transformer 120V primary, 24V secondary, 40VA transformer for powering backflow damper. OPTIONAL ACCESSORIES OPTIONS (-090, -135 MODELS ONLY) Whole-Home Dehumidistat Whole-Home Dehumidistat is used to control the dehumidifier if the unit is installed in a difficult to access location such as an attic or crawl space. Provides an accessible means of turning the dehumidifier on and off and allows for adjustment of the humidity level set point. Control contains its own sensors that override the dehumidifier’s main control board sensors. Basement Kit Includes components typically needed for basement dehumidification application. Includes two 8-in. normally open dampers, two 8-in. normally closed dampers and one 24V, 40VA transformer. Ventilation and Zone Dampers Constructed of rolled galvanized steel with stiffening ribs to maintain rigidity. A single steel offset blade is attached to a one piece aluminium shaft connected with nylon bearings for smooth operation. Spring return with a normally closed or normally open configurations are available.Requires 24V transformer ordered separately. Transformer 120V primary, 24V secondary, 40VA transformer for powering dampers. Outdoor Air Temperature Sensor Prevents the CCWH from using outside air for ventilation if the outdoor temperature is above 100°F or below 0°F. Ventilation (-090-135 MODELS ONLY) The built-in ventilation feature is designed to be meet ASHRAE 62.2 Standard for Ventilation. Utilizes the dehumidifier and furnace/air handler blower to make-up any remaining ventilation required based on chosen set point. In hot, humid climates, supplemental dehumidification of fresh air is recommended. Automatically monitors and controls the humidity of the incoming air. The dehumidifier can also operate an optional ventilation damper to bring air in from outside. To keep it from using outdoor air above 100°F or below 0°F, an optional Outdoor Temperature Sensor must be field installed. Air Cycling (-090-135 MODELS ONLY) An integrated air cycling feature can activate the furnace/air handler blower to cycle air through the house to balance the indoor air conditions. Monitors furnace/air handler blower run-time to efficiently ventilate the whole home, Air cycling will cycle furnace/air handler blower to the values set on the control. CCWH Complete Comfort Whole-Home Dehumidifier / Page 3 SPECIFICATIONS Model No. CCWH-065 CCWH-090 CCWH-135 Capacity 65 pints per day 90 pints per day 135 pints per day Refrigerant R-410A R-410A R-410A Ducted 52 48 54 Unducted 57 53 67 Drain diameter 3/4 3/4 3/4 Duct diameter 8 8 8 Inlet 30 - 99% 30 - 100% RH 30 - 100% RH Ambient Operating 0 - 100% 0-100% 0-100% 1 Sound Level (dBA) Connections - in. Humidity Range Blower Data Air Flow 150 cfm @ 0.5 in. w.c. 275 cfm @ 0.6 in. w.g. 500 cfm @ 0.8 in. w.g. Filter Electrical Type Washable, MERV 8 Washable, MERV 8 Washable, MERV 8 Size - in. 11-5/8 x 11-5/8 x 1 17 x 18 x 1 17 x 18 x 1 General 120V - 60 hz - 1 ph 120V - 60 hz - 1 ph 120V - 60 hz - 1 ph Power Supply 15 Amps 15 Amps 20 Amps Rated Amperage 8 Amps 8 Amps 14 Amps Connection Blower Motor Full Load Amps Weight - lbs. 8 ft.,3-prong power cord 1.6 1.1 65 93 100 REQUIRED COMPONENTS Backflow Damper 8 in. Normally Closed (NO) --- Y2264 Y2264 Transformer for Backflow Damper 24V, 40VA Transformer --- 22N03 22N03 --- X4471 X4471 Y3196 --- --- Ventilation Damper - 6 in. Normally Closed (NO) --- X4152 X4152 Zone Damper - 8 in. Normally Open (NO) --- X4209 X4209 Damper Transformer, 24V, 40VA --- 22N03 22N03 Whole-Home Dehumidistat --- CC139 CC139 Outdoor Air Temperature Sensor --- CC138 CC138 OPTIONAL ACCESSORIES Basement Kit - includes 2-8 in. NO dampers, 2-8 in. NC dampers, one 24V, 40VA transformer. Drain Pan (required for attic installations) Dampers 1 Capacity based on 60% relative humidity at 80°F (ANSI/AHAM DH-1-2003 conditions). CCWH Complete Comfort Whole-Home Dehumidifier / Page 4 PERFORMANCE CCWH-065 Dehumidifier Pressure/Airflow Curve Coil Dry, Air Filter Clean 1.20 External Static Pressure ("w.c.) 1.00 0.80 0.60 Filter Pressure Increase = 0.2" w.c. 0.40 Minimum Recommended Airflow = 140 CFM 0.20 Design System for 0.4" w.c. max. External Pressure Drop 0.00 0 50 100 150 200 250 Airflow (CFM) CCWH-090 Dehumidifier Pressure/Airflow Curve Coil Dry, Air Filter Clean 1.20 External Pressure Drop = HVAC System + Damper (0.05" w.c./unit) + 8" flex duct @ 275 cfm (Pressure drop of 8" flex @ 275 cfm = 0.23" w.c./100 feet) External Static Pressurre (" w.c.) 1.00 0.80 Filter Pressure Increase = 0.2" w.c. 0.60 Minimum Recommended Airflow = 200 CFM 0.40 Design System for 0.6" w.c. max. External Pressure Drop 0.20 0.00 0 50 100 150 200 250 300 350 400 450 Airflow (CFM) CCWH Complete Comfort Whole-Home Dehumidifier / Page 5 PERFORMANCE CCWH-135 Dehumidifier Pressure/Airflow Curve Coil Dry, Air Filter Clean 1.90 External Pressure Drop = HVAC System + Damper (0.05" w.c./unit) + 8" flex duct @ 500 cfm (Pressure drop of 8" flex @ 500 cfm = 0.75" w.c./100 feet) 1.70 External Static Pressurre (" w.c.) 1.50 Filter Pressure Increase = 0.2" w.c. 1.30 1.10 Minimum Recommended Airflow = 430 CFM 0.90 Design System for 1.3" max. External Pressure Drop 0.70 0.50 0.30 300 350 400 450 500 550 Airflow (CFM) CCWH-065 - CAPACITY - PINTS PER DAY Relative Temperature °F Humidity 60 65 70 75 80 50 ----30 41 52 55 --15 37 48 59 60 4 24 43 54 65 65 9 30 52 63 74 70 13 37 61 72 82 75 15 39 63 69 76 80 17 41 65 67 69 CCWH-065 - LEAVING AIR TEMPERATURE Relative Temperature °F Humidity 60 65 70 75 80 50 ----92 101 110 55 --80 93 103 113 60 68 81 93 105 116 65 74 86 98 108 118 70 80 91 102 111 120 75 81 92 103 111 118 80 81 93 104 110 116 85 54 62 69 65 61 56 52 85 115 119 122 119 117 115 113 90 56 65 74 56 39 37 35 CCWH-065 - ENERGY USE - PINTS PER KW/HR Relative Temperature °F Humidity 60 65 70 75 80 85 50 ----2.11 2.53 2.96 3.06 55 --1.06 2.43 2.75 3.06 3.22 60 0.21 1.48 2.75 2.96 3.17 3.38 65 0.95 2.11 3.27 3.48 3.70 3.59 70 1.69 2.75 3.80 4.01 4.22 3.80 75 2.11 3.01 3.91 4.07 4.22 3.75 80 2.53 3.27 4.01 4.12 4.22 3.70 90 3.17 3.38 3.59 3.48 3.38 3.27 3.17 90 120 124 128 121 113 112 110 CCWH-065 - LEAVING AIR % RELATIVE HUMIDITY Relative Temperature °F Humidity 60 65 70 75 80 85 50 ----19 16 13 13 55 --25 19 16 13 13 60 30 24 18 16 13 14 65 29 23 17 15 13 18 70 28 22 15 14 13 23 75 25 21 18 18 18 26 80 22 21 20 21 22 28 90 13 14 14 24 33 34 34 CCWH-065 CAPACITY AND ENERGY USAGE VS. STATIC PRESSURE Static Pressure - in. w.g. 0.0 0.3 0.5 Capacity - Pints Per Day 69 65 61 Energy Usage - Pints per kW/Hr 4.50 4.03 3.67 NOTE - Tested at 80°F/60% relative humidity. CCWH Complete Comfort Whole-Home Dehumidifier / Page 6 0.8 51 2.89 PERFORMANCE CCWH-090 - CAPACITY - PINTS PER DAY Relative Temperature °F Humidity 60 65 70 75 80 50 --16 48 57 66 55 6 31 60 69 78 60 11 47 73 81 90 65 26 58 84 93 102 70 41 70 95 104 114 75 55 85 104 114 124 80 69 101 112 123 134 CCWH-090 - LEAVING AIR TEMPERATURE Relative Temperature °F Humidity 60 65 70 75 80 50 --74 84 90 97 55 71 76 86 92 98 60 74 79 88 93 100 65 75 80 90 96 104 70 76 81 92 97 107 75 78 84 93 100 108 80 81 88 93 102 109 CCWH-135 - CAPACITY - PINTS PER DAY Relative Temperature °F Humidity 60 65 70 75 80 50 --15 50 74 99 55 19 32 76 97 117 60 17 60 103 119 135 65 39 81 123 138 153 70 62 102 142 157 171 75 82 119 155 170 186 80 103 136 168 184 200 CCWH-135 - LEAVING AIR TEMPERATURE Relative Temperature °F Humidity 60 65 70 75 80 50 --71 84 92 100 55 68 74 87 94 102 60 73 81 90 97 105 65 76 84 92 99 106 70 79 87 95 101 108 75 82 89 95 103 110 80 85 91 96 104 112 85 76 88 100 111 122 135 147 85 103 104 106 110 112 114 115 85 114 129 144 161 177 193 209 85 105 108 111 113 115 117 119 90 86 98 110 120 130 146 161 CCWH-090 - ENERGY USE - PINTS PER KW/HR Relative Temperature °F Humidity 60 65 70 75 80 85 50 --1.03 2.91 3.26 3.61 3.95 55 0.42 1.97 3.59 3.89 4.19 4.49 60 1.06 2.91 4.27 4.52 4.77 5.04 65 2.11 3.59 4.79 5.01 5.23 5.43 70 3.17 4.26 5.32 5.50 5.68 5.83 75 3.80 5.02 5.79 5.95 6.11 6.26 80 4.65 5.79 6.25 6.40 6.55 6.70 90 4.29 4.79 5.30 5.64 5.98 6.41 6.84 90 109 109 111 114 116 120 124 CCWH-090 - LEAVING AIR % RELATIVE HUMIDITY Relative Temperature °F Humidity 60 65 70 75 80 85 50 --34 26 24 23 22 55 37 33 26 24 23 22 60 35 30 26 24 23 23 65 34 30 26 24 23 22 70 33 30 26 24 22 22 75 31 28 26 24 23 22 80 28 26 26 24 23 23 90 22 22 22 23 23 23 22 90 130 142 154 169 184 201 217 CCWH-135 - ENERGY USE - PINTS PER KW/HR Relative Temperature °F Humidity 60 65 70 75 80 85 50 --0.84 1.65 2.11 2.32 2.53 55 0.91 1.55 2.32 2.75 3.17 3.38 60 1.06 1.69 2.96 3.38 3.85 3.80 65 1.48 2.53 3.38 3.80 4.22 4.22 70 2.11 3.17 4.01 4.44 4.65 4.44 75 2.96 3.80 4.65 4.86 4.86 4.86 80 3.59 4.22 5.07 5.28 5.49 5.49 90 2.96 3.59 4.01 4.22 4.35 4.86 5.70 90 111 114 117 119 123 124 126 CCWH-135 - LEAVING AIR % RELATIVE HUMIDITY Relative Temperature °F Humidity 60 65 70 75 80 85 50 --40 28 24 21 21 55 43 40 28 23 21 21 60 42 36 28 23 21 21 65 41 36 28 24 21 21 70 39 34 28 24 21 21 75 38 31 28 23 21 21 80 38 32 28 25 21 20 90 20 21 21 22 22 21 19 CCWH-135 CAPACITY AND ENERGY USAGE VS. STATIC PRESSURE Static Pressure - in. w.g. 0 0.5 0.7 Capacity - Pints Per Day 137 136 135 Energy Usage - Pints per kW/Hr 3.92 3.86 3.84 0.9 135 3.85 1.3 133 3.78 1.5 131 3.61 NOTE - Tested at 80°F/60% relative humidity. CCWH Complete Comfort Whole-Home Dehumidifier / Page 7 SIZING GUIDELINES 1. Find the home location (and corresponding region) in the map below 2. Estimate the air change rate of the home: a. 1.00 air change per hour is an older home, that is not particularly tight. b. 0.50 air change per hour is a reasonably tight home. c. 0.35 air change per hour is a very tight home, typical of new home construction. 3. Determine how many dehumidifiers are required by comparing the actual home size and corresponding air change rate, to the “Maximum Recommended Home Size” in the table. 4. This is a general guideline. Consider any special circumstances that may require more water removal capacity and, if necessary, adjust your dehumidifier choice(s) accordingly. A B C CCWH-065 CCWH-090 CCWH-135 Air Change Per Hour (ACH) 1.00 0.50 0.35 1.00 0.50 0.35 1.00 0.50 0.35 Maximum Recommended Home Size (sq. ft.) Region A 2600 3600 3600 3600 5000 5000 5400 7400 7400 Region B 2000 3200 3600 2800 4500 5000 4100 6700 7400 Region C 1200 1800 2400 1700 2600 3400 2500 3800 5000 NOTES: - Based on a single-story, slab construction home with four occupants. - Dehumidistats set to less dry; thermostat set to auto-fan. - Air conditioner with thermostat cooling set to at least 79°F. - TMY 2 (Typical Meteorological Year) weather data; 1.00 lb./hr. internal moisture gain due to occupants. CCWH Complete Comfort Whole-Home Dehumidifier / Page 8 TYPICAL APPLICATIONS CENTRAL APPLICATION (All Models) AIR HANDLER OR FURNACE SUPPLY AIR FLOW RETURN AIR FLOW **OPTIONAL VENTILATION DAMPER HCWH DEHUMIDIFIER DEHUMIDIFIED AIR OUTDOOR AIR INTAKE *BACKFLOW DAMPER Note - HCWC bypass ducts must be a minimum of 6 in. (127 mm) from the supply or return air openings of the air handler/furnace *Backflow damper is furnished on HCWH-065 Model, optional for HCWH-090-135 Models. **For use with HCWH-090-135 Models only. ZONED APPLICATION (All Models) OUTDOOR AIR INTAKE OPTIONAL VENTILATION DAMPER SUPPLY AIR FLOW AIR HANDLER OR FURNACE DEHUMIDIFIED AIR RETURN AIR FLOW HCWH DEHUMIDIFIER AIR FLOW ENTERING AIR COMBINATION CENTRAL AND ZONED APPLICATION (CCWH-090-135 Models Only) AIR HANDLER OR FURNACE SUPPLY AIR FLOW RETURN AIR FLOW NORMALLY CLOSED DAMPER NORMALLY CLOSED DAMPER NORMALLY OPEN DAMPER DEHUMIDIFIED AIR NORMALLY OPEN DAMPER HCWH DEHUMIDIFIER ENTERING AIR OPTIONAL VENTILATION DAMPER OUTDOOR AIR INTAKE CCWH Complete Comfort Whole-Home Dehumidifier / Page 9 DIMENSIONS - INCHES (MM) CCWH-065 2-1/2 Wiring (64) Access 13-1/8 (333) 2-1/2 (64) 22-1/8 (562) 13-1/8 (333) Humidity Control OFF/ON Switch 14-1/2 (368) 8 (203) Dia. 4 (102) Max. Adjustable Legs 8 (203) Dia. Air Flow OUTLET AIR END 1 (25) 1-3/8 (35) Filter Access (Front and Back) Power Cord Drain FRONT VIEW INLET AIR END CCWH-090 AND CCWH-135 2-1/2 (64) 20-3/4 (527) 24 (610) 2-1/2 (64) Humidity Control 8 in. Dia. OFF/ON Switch 8 in. Dia. 10-3/8 (264) OUTLET AIR END 19-5/8 (498) Air Flow OFF ON Wiring Access Drain 1-1/4 (32) 20-3/4 (527) Filter Access (Front and Back) Power Cord FRONT VIEW CCWH Complete Comfort Whole-Home Dehumidifier / Page 10 Adjustable Legs INLET AIR END 3 (76) Max. INSTALLATION CLEARANCES - INCHES (MM) CCWH-065 Support struts for suspending (bottom of unit) 2-1/8 (54) clearance from leveling feet 12 in. (305 mm) control access clearance, both ends SERVICE CLEARANCE 12 in. (305 mm) filter/front panel service clearance (either side) 4-1/2 in. (114 mm) filter access panel clearance (either side) If suspending the unit, use two struts to support the base on the outside edges of the feet locations. NOTE - Minimum clearance of 3 in. (76 mm) from unit to strut suspension rod (access panel side only) is required for filter panel access removal. CCWH-090 AND CCWH-135 Support struts for suspending (bottom of unit) TOP VIEW OF UNIT 12 in. (305 mm) control access clearance, both ends See NOTE SERVICE CLEARANCE 20 in. (508 mm) filter/front panel service clearance (either side) 6 in. (152 mm) filter access panel clearance (either side) If suspending the unit, use two struts to support the base on the outside edges of the feet locations. NOTE - Minimum clearance of 3 in. (76 mm) from unit to strut suspension rod (access panel side only) is required for filter panel access removal. CCWH Complete Comfort Whole-Home Dehumidifier / Page 11 REVISIONS Approvals Added ENERGY STAR® rating for CCWH-065 model. Document Added performance data for all models. Visit us at www.alliedair.com For the latest technical information, www.alliedair.com Contact us at 800-448-5872 NOTE: Due to Allied Air Enterprises’ ongoing commitment to quality, specifications, ratings and dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and serivce must be performed by a qualified installer and servicing agency. A Lennox International Inc. Company ©2011 Allied Air Enterprises, a Lennox International Inc. Company Form Number: CCWH (08/2011)