Ceramic Infrared Panel Radiators HTS

Transcription

Ceramic Infrared Panel Radiators HTS
HTS
Ceramic Infrared Panel Radiators
Elstein HTS high temperature radiators are ceramic infrared panel radiators, which can be used for operating
temperatures up to 860 °C and surface ratings up to
64 kW/m².
ELSTEIN HTS/1 1000
230V 1000W 900 °C max.
HTS series radiators are produced using a hollowcasting ceramic process and are filled with thermal
insulation material. This improves the radiant power
output to the material to be heated.
ELSTEIN HTS/2 500
230V 500W 900 °C max.
Furthermore, there is a significant reduction in heat
dissipated in the wiring space, so that additional insulation of the heating area is usually not required.
Made in
Germany
Compared with IR radiators, which are produced using
full-poured casting processes, HTS radiators have a
considerably reduced heating-up time and, depending
on the type of application, enable energy savings of
up to 25 %.
606
Elstein HTS high temperature radiators are available in
four designs and cover the power range from 60 W to
1000 W.
Figure 39: Elstein HTS series
HTS
85
125 (122)
15
40
max. 1.5
35
30 (28)
125
(122)
HTS/1
85
62.5 (60)
15
max. 1.5
40
250
(245)
35
30 (28)
HTS/2
85
62.5 (60)
15
max. 1.5
40
125
(122)
35
30 (28)
HTS/4
85
62.5 (60)
15
max. 1.5
40
62.5
(60)
35
30 (28)
Figure 40: Mounting dimensions and radiator dimensions ( ) in mm
Page 18
HTS
°C
%
1000
100
1000 W
80
800 W
60
600 W
40
400 W
1000 W
800 W
800
600 W
600
400 W
250 W
400
250 W
20
200
0
0
0
2
4
6
8
10
0
min
2
6
4
8
10
min
Fig. 42: Radiant powers
Heating-up: red curves
Cooling-down: blue curve
Fig. 41: Radiator temperatures
Heating-up: red curves
Cooling-down: blue curve
HTS/1, HTS
220 g
250
400
600
800
1000
W
HTS/2
125 g
125
200
300
400
500
W
HTS/4
75 g
60
100
150
200
250
W
Surface rating
16.0
25.6
38.4
51.2
64.0
kW/m²
Typical operating temperature
450
570
700
810
860
°C
Maximum permissible temperature
900
900
900
900
900
°C
Type, weight, wattage
Wavelength range
2
-
10
Standard design
Thermocouple radiators
Variants
Operating voltage 230 V
Ceramic hollow casting
Integrated thermal insulation
Leads 85 mm
Elstein standard socket
Mounting set
Designation T-HTS, T-HTS/1,
T-HTS/2, T-HTS/4
Integrated thermocouple
Type K (NiCr-Ni)
TC leads 100 mm
Special wattages
Special voltages
Extended leads
Leads with ring terminals
µm
The power can be controlled using thermocouple radiators together with TRD 1 temperature controllers, TSE
thyristor switching units and other accessories.
IR radiation areas can be assembled using REO reflectors, REF construction sets, EBF construction elements,
MBO mounting sheets and BSI construction panels.
The national safety regulations must be complied with for the respective application, for example, the IEC or EN
standard 60519-1, Safety in electrical heating installations.
Further information and safety information are given in this document and in the mounting instruction enclosed
with each radiator.
Page 19

Similar documents

re82 temperature controller e i o

re82 temperature controller e             i         o voltage 0/5 V continuous current: 0/4 .. 20 mA continuous voltage: 0 .. 10 V Supply of transducers:

More information

TC40 Industrial Thermocouple Sensor

TC40 Industrial Thermocouple Sensor „„ The sensor can be mounted into a process with the use of a fixed fitting, compression fitting, union nut, swivel nut or a spring-loaded bushing. „„ The sensor has electrical approvals for intrin...

More information