Analyzers - IncellDx

Transcription

Analyzers - IncellDx
Personalizing Infectious Disease Testing™
Analyzers
Powerful, yet amazingly easy to use.
Fast, Flexible, Easy
The new Goldfish/Bluefish™ flow cytometers represent the latest innovation
in cellular analysis. Designed as robust benchtop analyzers, their workflow
is simple yet able to automate multiple flow-based protocols.
• No nucleic acid extraction required
• Rapid analysis of up to 10,000 events per second
• Intuitive software for easy interpretation of results
• Complete solution for IncellDx™ assays
• Adaptable to other assays
Simple operation
Versatile sample handling
Compact yet powerful, the Goldfish/Bluefish™ analyzers
are able to perform modern clinical applications with
ease. And they can calculate cell concentration without
any requirement to add beads to the sample or perform
time-consuming hemocytometer counts.
For convenience the Goldfish/Bluefish™ fluidics
systems are non-pressurized. Any brand of sample
tube 12x75mm or smaller can be used, including
microfuge tubes and tubes made of polypropylene
or polystyrene.
High performance in a small package
Intuitive software that is easy to use
The Goldfish/Bluefish™ analyzers are equipped with
either 1 or 2 lasers and either three or four fluorescence
detectors with interference filters optimized for the
detection of FITC, PE and PE-CY5.
The Goldfish/Bluefish™ user interface is incredibly easy
to learn. Most users collect and analyze data in less
than 30 minutes. Drag and drop plots into Microsoft®
Office applications and copy/paste statistics directly
into spreadsheets.
PERSONALIZING INFECTIOUS DISEASE TESTING
SUSHI* Workflow
Fix 300 ul
▲
Wash
▲
▲
▲
Transfer
1 Hour
Wash 2x
*Simultaneous Ultrasensitive Selective Hybridization In Situ
C-Flow: Plot 3
P2 Molecular
Analysis
Wash 2x
▲
C-Flow: Plot 2
P1 Molecular
Analysis
30 min
▲
C-Flow: Plot 1
Cell Population
▲
▲
Stain 103 ul
15 min
Re-suspend
IncellDx Products:
H 11.0" (27.9 cm)
Hybridization Core Kit
HPV E6, E7 mRNA Probe
HIV VR Probe
HIV Tropism Probe
incellCount CD4/CD8
incellFP (2x)
incellTROL HPV Positive
incellTROL HPV Negative
HPV OncoTect® Kit
W 14.3" (36.3 cm)
D 16.5" (41.9 cm)
( FRONT VIEW )
( SIDE VIEW )
Goldfish/Bluefish Analyzer Specifications
Instrument size
11.0" H x 14.3" W x 16.5" D (27.9 x 36.3 x 41.9 cm)
Fluidics bottle tray
10" H x 13.5" W x 4.5" D (25.4 x 34.2 x 11.4 cm)
Weight
< 30 lbs (13.6 kg)
Emission detection
488 Excitation (Bluefish and Goldfish):
FL1: 533±15nm (FITC/GFP)
FL2: 585±20nm (PE/PI)
FL3: >670nm (PerCP-Cy5.5, PE-Cy5, PE-Cy7)
(using standard filter set provided)
640 Excitation (Goldfish):
As above plus: FL4: 675+12.5 nm (APC)
Optical alignment
Fixed alignment, no maintenance required
Scatter resolution
Resolves human peripheral blood erythrocytes,
lymphocytes, monocytes, and granulocytes
Fluorescence linearity
2.00+0.05% for chick erythrocyte nuclei (CEN)
Fluorescence precision
< 3.0% CV for CEN
Max. event rate
10,000 events/second
Signal processing
24-bit A/D conversion
Software
IncellDx CFlow or IncellDx CFlow Plus Software
To Order:
Goldfish™ (S76000): 2 lasers, 6 parameters, 4 colors
Offers enhanced capabilities including time as an output, sample volume tracking
and event concentration, absolute counts and fine control of core size and flow rate.
Bluefish™ (S75000): 1 laser, 5 parameters, 3 colors plus C-Flow software
Upgraded capabilities to meet your evolving research needs.
1700 El Camino Real
Menlo Park, CA 94027
Phone: 1 650 777 7630
www.incelldx.com
Contact IncellDx™ today at +1.650.777.7630 for pricing information.
Instrument is for Research Use Only. Not for use in diagnostic procedures.
©2011 IncellDx, Inc. Item Number: 400103_01