Analyzers - IncellDx
Transcription
Analyzers - IncellDx
Personalizing Infectious Disease Testing™ Analyzers Powerful, yet amazingly easy to use. Fast, Flexible, Easy The new Goldfish/Bluefish™ flow cytometers represent the latest innovation in cellular analysis. Designed as robust benchtop analyzers, their workflow is simple yet able to automate multiple flow-based protocols. • No nucleic acid extraction required • Rapid analysis of up to 10,000 events per second • Intuitive software for easy interpretation of results • Complete solution for IncellDx™ assays • Adaptable to other assays Simple operation Versatile sample handling Compact yet powerful, the Goldfish/Bluefish™ analyzers are able to perform modern clinical applications with ease. And they can calculate cell concentration without any requirement to add beads to the sample or perform time-consuming hemocytometer counts. For convenience the Goldfish/Bluefish™ fluidics systems are non-pressurized. Any brand of sample tube 12x75mm or smaller can be used, including microfuge tubes and tubes made of polypropylene or polystyrene. High performance in a small package Intuitive software that is easy to use The Goldfish/Bluefish™ analyzers are equipped with either 1 or 2 lasers and either three or four fluorescence detectors with interference filters optimized for the detection of FITC, PE and PE-CY5. The Goldfish/Bluefish™ user interface is incredibly easy to learn. Most users collect and analyze data in less than 30 minutes. Drag and drop plots into Microsoft® Office applications and copy/paste statistics directly into spreadsheets. PERSONALIZING INFECTIOUS DISEASE TESTING SUSHI* Workflow Fix 300 ul ▲ Wash ▲ ▲ ▲ Transfer 1 Hour Wash 2x *Simultaneous Ultrasensitive Selective Hybridization In Situ C-Flow: Plot 3 P2 Molecular Analysis Wash 2x ▲ C-Flow: Plot 2 P1 Molecular Analysis 30 min ▲ C-Flow: Plot 1 Cell Population ▲ ▲ Stain 103 ul 15 min Re-suspend IncellDx Products: H 11.0" (27.9 cm) Hybridization Core Kit HPV E6, E7 mRNA Probe HIV VR Probe HIV Tropism Probe incellCount CD4/CD8 incellFP (2x) incellTROL HPV Positive incellTROL HPV Negative HPV OncoTect® Kit W 14.3" (36.3 cm) D 16.5" (41.9 cm) ( FRONT VIEW ) ( SIDE VIEW ) Goldfish/Bluefish Analyzer Specifications Instrument size 11.0" H x 14.3" W x 16.5" D (27.9 x 36.3 x 41.9 cm) Fluidics bottle tray 10" H x 13.5" W x 4.5" D (25.4 x 34.2 x 11.4 cm) Weight < 30 lbs (13.6 kg) Emission detection 488 Excitation (Bluefish and Goldfish): FL1: 533±15nm (FITC/GFP) FL2: 585±20nm (PE/PI) FL3: >670nm (PerCP-Cy5.5, PE-Cy5, PE-Cy7) (using standard filter set provided) 640 Excitation (Goldfish): As above plus: FL4: 675+12.5 nm (APC) Optical alignment Fixed alignment, no maintenance required Scatter resolution Resolves human peripheral blood erythrocytes, lymphocytes, monocytes, and granulocytes Fluorescence linearity 2.00+0.05% for chick erythrocyte nuclei (CEN) Fluorescence precision < 3.0% CV for CEN Max. event rate 10,000 events/second Signal processing 24-bit A/D conversion Software IncellDx CFlow or IncellDx CFlow Plus Software To Order: Goldfish™ (S76000): 2 lasers, 6 parameters, 4 colors Offers enhanced capabilities including time as an output, sample volume tracking and event concentration, absolute counts and fine control of core size and flow rate. Bluefish™ (S75000): 1 laser, 5 parameters, 3 colors plus C-Flow software Upgraded capabilities to meet your evolving research needs. 1700 El Camino Real Menlo Park, CA 94027 Phone: 1 650 777 7630 www.incelldx.com Contact IncellDx™ today at +1.650.777.7630 for pricing information. Instrument is for Research Use Only. Not for use in diagnostic procedures. ©2011 IncellDx, Inc. Item Number: 400103_01