Cree 304 Series Flood Luminaire Spec Sheet
Transcription
Cree 304 Series Flood Luminaire Spec Sheet
304 Series™ LED Flood Luminaire Product Description Slim, low profile design. Luminaire is constructed from rugged die cast and extruded aluminum components. LED driver is mounted in a sealed weathertight center chamber that allows for access from below the luminaire. High performance heat sinks specifically designed for LED floodlight application. Luminaire mounts with stainless steel adjustable yoke mount which allows for +/- 90˚ adjustment in 5˚ increments. Applications: Underpasses and sign lighting 12.0" SQ (305mm) Performance Summary Patented NanoOptic® Product Technology Made in the U.S.A. of U.S. and imported parts 7.3" (184mm) CRI: Minimum 70 CRI CCT: 4000K (+/- 300K), 5700K (+/- 500K) standard Limited Warranty†: 10 years on luminaire/10 years on Colorfast DeltaGuard® finish † See http://lighting.cree.com/warranty for warranty terms Accessories Multi-Level Sensor location (ordered as an option) 14.5" (367mm) Field-Installed Hand-Held Remote XA-SENSREM - For successful implementation of the programmable multi-level option, a minimum of one hand-held remote is required 7.3" 7.8" (184mm) (197mm) 12.8" (325mm) 7.5" (191mm) Ø0.3" (8mm) 1.5" (38mm) LED Count (x10) Weight 04 23 lbs. (10.4kg) 06 23 lbs. (10.4kg) Ordering Information Example: FLD-304-2M-YM-04-E-UL-SV-350 FLD-304 YM Product Optic FLD-304 2M Type II Medium 3M Type III Medium 5M Type V Medium 5S Type V Short N6 NEMA® 6 SL Sparkle Petroleum SN Sign 15 15˚ Flood 25 25˚Flood 40 40˚ Flood 70 70˚Flood E Mounting LED Count (x10) YM Yoke 04 06 Series Voltage E UL Universal 120-277V UH Universal 347-480V Color Options SV Silver BK Black BZ Bronze WH White Drive Current Options 350 350mA 525 525mA 700 700mA DIM 0-10V Dimming -- Control by others -- Refer to Dimming spec sheet for details -- Can't exceed specified drive current FFuse -- When code dictates fusing, use time delay fuse -- Refer to ML spec sheet for availability with ML options -- Available with UL voltage only MLMulti-Level -- Refer to ML spec sheet for details -- Intended for downlight applications at 0˚ tilt PML Programmable Multi-Level, 10-30' Mounitng Height -- Refer to PML spec sheet for details -- Intended for downlight applications at 0˚ tilt 40K 4000K Color Temperature -- Minimum 70 CRI -- Color temperature per luminaire Rev. Date: V3 01/19/2016 US: lighting.cree.com/lighting T (800) 236-6800 F (262) 504-5415 Canada: www.cree.com/canada T (800) 473-1234 F (800) 890-7507 304 Series™ LED Flood Luminaire Product Specifications Electrical Data* CONSTRUCTION & MATERIALS • Slim, low profile design • Luminaire is constructed from rugged die cast and extruded aluminum components LED Count (x10) • LED driver is mounted in a sealed weathertight center chamber that allows for access from below the luminaire 350mA • 3' (0.9m) SEOW cord exits street side of luminaire through 1/2" (13mm) NPT cable gland System Watts 120-480V Total Current 120V 208V 240V 277V 347V 480V 04 46 0.39 0.24 0.22 0.21 0.15 0.12 • High performance aluminum heat sinks specifically designed for LED floodlight applications 06 69 0.57 0.34 0.30 0.27 0.21 0.16 • Luminaire mounts with stainless steel adjustable yoke which allows for +/- 90˚ adjustment in 5˚ increments 525mA 04 71 0.59 0.35 0.31 0.28 0.21 0.16 06 101 0.84 0.49 0.43 0.38 0.30 0.22 04 94 0.79 0.46 0.40 0.36 0.28 0.21 06 135 1.14 0.65 0.57 0.50 0.40 0.29 • Exclusive Colorfast DeltaGuard finish features an E-Coat epoxy primer with an ultradurable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. Black, bronze, silver, and white are available ® • Weight: 40 LED: 23 lbs. (10.4kg); 60 LED: 23 lbs. (10.4kg) 700mA ELECTRICAL SYSTEM • Input Voltage: 120-277V or 347-480V, 50/60Hz, Class 1 drivers • Power Factor: > 0.9 at full load • Total Harmonic Distortion: < 20% at full load • Integral 10kV surge suppression protection standard * Electrical data at 25˚C (77˚F). Actual wattage may differ by +/- 10% when operating between 120-480V +/- 10% • To address inrush current, slow blow fuse or type C/D breaker should be used • 10V Source Current: 0.15mA Recommended 304 Series™ Flood Lumen Maintenance Factors (LMF)1 REGULATORY & VOLUNTARY QUALIFICATIONS • cULus Listed • Suitable for wet locations Ambient Initial LMF 25K hr Projected2 LMF 50K hr Projected2 LMF 75K hr Calculated3 LM 100K hr Calculated3 LMF 5˚C (41˚F) 1.04 0.99 0.97 0.95 0.93 10˚C (50˚F) 1.03 0.98 0.96 0.94 0.92 15˚C (59˚F) 1.02 0.97 0.95 0.93 0.91 20˚C (68˚F) 1.01 0.96 0.94 0.92 0.90 25˚C (77˚F) 1.00 0.95 0.93 0.91 0.89 • Enclosure rated IP66 per IEC 60529 • Consult factory for CE Certified products • Certified to ANSI C136.31-2001, 3G bridge and overpass vibration standards • 10kV surge suppression protection tested in accordance with IEEE/ANSI C62.41.2 • Luminaire and finish endurance tested to withstand 5,000 hours of elevated ambient salt fog conditions as defined in ASTM Standard B 117 • Meets Buy American requirements within ARRA • Meets FCC Part 15, Subpart B, Class A standards for conducted and radiated emissions • RoHS compliant. Consult factory for additional details Lumen maintenance values at 25˚C (77˚F) are calculated per TM-21 based on LM-80 data and in-situ luminaire testing In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on time durations that are within six times (6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip) 3 In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times (6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip) 1 2 US: lighting.cree.com/lighting T (800) 236-6800 F (262) 504-5415 Canada: www.cree.com/canada T (800) 473-1234 F (800) 890-7507 304 Series™ LED Flood Luminaire Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool 2M 150˚ 7551 150˚ 100' 80' 60' 40' 20' 60' 5663 120˚ 120˚ 3776 80' 100' 20' 40' 60' 74˚ 18.3 90˚ 40' 2 0m 6.1 CURB LINE 12.2 60' 0m Initial Delivered Lumens* BUG Ratings** Per TM-15-11 Initial Delivered Lumens* BUG Ratings** Per TM-15-11 04 4,368 B1 U0 G1 4,536 B2 U0 G2 06 6,501 B2 U0 G2 6,751 B2 U0 G2 04 6,115 B2 U0 G2 6,350 B2 U0 G2 06 9,101 B3 U0 G3 9,451 B3 U0 G3 04 7,425 B2 U0 G2 7,711 B2 U0 G2 06 11,051 B3 U0 G3 11,476 B3 U0 G3 350mA Position of vertical plane of maximum candlepower. Candlepower Trace: Vertical plane through 30º horizontal angle of maximum candlepower. FLD-304-2M-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G. Initial Delivered Lumens: 11,476 Initial FC at grade ITL Test Report #: 77237 STR-LWY-2M-**-06-E-UL-700-40K Initial Delivered Lumens: 11,094 5700K 6.1 12.2 18.3 24.4 30.5 60˚ 30˚ LED Count (x10) 18.3 30.5 24.4 18.3 12.2 6.1 60˚ 4000K 6.1 .1 .2 .5 1 20' 90˚ Type II Medium Distribution 12.2 20' 0' 1888 0' 40' 525mA 700mA * Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt 3M 150˚ 4634 150˚ 100' 120˚ 120˚ 2317 80' 60' 40' 0' 20' 20' 40' 60' 80' 100' 60˚ 60' 20' 20' .5 6.1 1 0m CURB LINE 6.1 40' 60˚ 60˚ Candlepower Trace: Vertical plane through 30º horizontal angle of maximum candlepower. CESTL Test Report #: 2013-0068 STR-LWY-3M-**-06-E-UL-700-40K Initial Delivered Lumens: 10,430 4000K LED Count (x10) 18.3 80' 24.4 0m 6.1 30.5 12.2 18.3 24.4 30.5 Position of vertical plane of maximum candlepower. FLD-304-3M-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G. Initial Delivered Lumens: 10,880 Initial FC at grade 5700K Initial Delivered Lumens* BUG Ratings** Per TM-15-11 Initial Delivered Lumens* BUG Ratings** Per TM-15-11 04 4,141 B1 U0 G1 4,300 B1 U0 G1 06 6,163 B2 U0 G2 6,400 B2 U0 G2 04 5,797 B2 U0 G2 6,020 B2 U0 G2 06 8,628 B2 U0 G2 8,960 B2 U0 G2 04 7,039 B2 U0 G2 7,310 B2 U0 G2 06 10,477 B3 U0 G3 10,880 B3 U0 G3 12.2 60' 100' 30.5 24.4 18.3 12.2 6.1 30˚ Type III Medium Distribution 12.2 2 .1 .2 0' 90˚ 30.5 24.4 18.3 40' 1159 90˚ 100' 80' 3476 350mA 525mA 700mA * Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt US: lighting.cree.com/lighting T (800) 236-6800 F (262) 504-5415 Canada: www.cree.com/canada T (800) 473-1234 F (800) 890-7507 304 Series™ LED Flood Luminaire Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool 5M 150˚ 3892 150˚ 100' 100' 80' 60' 40' 20' 0' 40' 20' 60' 80' 100' 0˚ 80' 2919 120˚ 120˚ 1946 18.3 40' 12.2 20' 973 .1 .2 .5 0' 90˚ 90˚ 20' 6.1 1 0m CURB LINE 6.1 40' 60˚ 60˚ 30˚ Type V Medium Distribution 4000K LED Count (x10) 18.3 80' 24.4 100' 30.5 24.4 18.3 12.2 6.1 0m 6.1 30.5 12.2 18.3 24.4 30.5 Position of vertical plane of maximum candlepower. FLD-304-5M-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G. Initial Delivered Lumens: 12,072 Initial FC at grade 5700K Initial Delivered Lumens* BUG Ratings** Per TM-15-11 Initial Delivered Lumens* BUG Ratings** Per TM-15-11 04 4,595 B3 U0 G1 4,771 B3 U0 G1 06 6,838 B3 U0 G2 7,101 B3 U0 G2 04 6,433 B3 U0 G2 6,680 B3 U0 G2 06 9,574 B3 U0 G2 9,942 B3 U0 G2 04 7,811 B3 U0 G2 8,111 B3 U0 G2 06 11,625 B4 U0 G2 12,072 B4 U0 G2 12.2 60' Candlepower Trace: Vertical plane through horizontal angle of maximum 30ºcandlepower. ITL Test Report #: 78147 PKG-304-5M-**-06-E-UL-700 Initial Delivered Lumens: 12,508 30.5 24.4 60' 350mA 525mA 700mA * Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt 5S 150˚ 4941 100' 150˚ 100' 80' 60' 40' 20' 120˚ 120˚ 0' 20' 40' 60' 80' 100' 30.5 45˚ 80' 3706 6.1 20' 1235 0' 90˚ 90˚ 20' 1 .2 .5 1 0m CURB LINE 60˚ 30˚ Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower. ITL Test Report #: 77876 PKG-304-5S-**-06-E-UL-700-40K Initial Delivered Lumens: 12,738 4000K 6.1 LED Count (x10) 60' 18.3 80' 24.4 100' 30.5 30.5 24.4 18.3 12.2 6.1 0m 6.1 12.2 18.3 24.4 30.5 Position of vertical plane of maximum candlepower. FLD-304-5S-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G. Initial Delivered Lumens: 13,413 Initial FC at grade 5700K Initial Delivered Lumens* BUG Ratings** Per TM-15-11 Initial Delivered Lumens* BUG Ratings** Per TM-15-11 04 5,105 B2 U0 G1 5,302 B2 U0 G1 06 7,598 B3 U0 G1 7,890 B3 U0 G1 04 7,147 B3 U0 G1 7,422 B3 U0 G1 06 10,637 B3 U0 G2 11,046 B3 U0 G2 04 8,679 B3 U0 G1 9,013 B3 U0 G1 06 12,917 B3 U0 G2 13,413 B3 U0 G2 12.2 40' 60˚ Type V Short Distribution 12.2 40' 2471 24.4 18.3 60' 350mA 525mA 700mA * Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt US: lighting.cree.com/lighting T (800) 236-6800 F (262) 504-5415 Canada: www.cree.com/canada T (800) 473-1234 F (800) 890-7507 304 Series™ LED Flood Luminaire Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool SL 150˚ 4444 100' 150˚ 100' 80' 60' 40' 20' 0' 20' 40' 60' 80' 100' 30.5 80' 3333 120˚ 120˚ 2222 1111 Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower. 60˚ .2 4000K 6.1 .5 1 2 LED Count (x10) 0m CURB LINE 6.1 60' 18.3 80' 24.4 Position of vertical plane of maximum candlepower. FLD-304-SL-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G. Initial Delivered Lumens: 13,264 Initial FC at grade ITL Test Report #: 77415 CAN-304-SL-**-06-E-UL-700-40K Initial Delivered Lumens: 12,707 BUG Ratings** Per TM-15-11 Initial Delivered Lumens* BUG Ratings** Per TM-15-11 04 5,048 B2 U0 G1 5,243 B2 U0 G1 06 7,514 B3 U0 G1 7,803 B3 U0 G1 04 7,068 B2 U0 G1 7,340 B2 U0 G1 06 10,519 B3 U0 G1 10,924 B3 U0 G1 04 8,582 B3 U0 G1 8,912 B3 U0 G1 06 12,773 B3 U0 G1 13,264 B3 U0 G1 350mA 100' 30.5 30.5 24.4 18.3 12.2 6.1 0m 6.1 12.2 18.3 24.4 30.5 30˚ 5700K Initial Delivered Lumens* 12.2 40' 60˚ 30˚ .1 0' 20' 90˚ 18.3 12.2 40' 20' 90˚ Sparkle Petroleum Distribution 24.4 45˚ 60' 525mA 700mA * Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt SN 150˚ 22629 150˚ 40' 80' 16972 120˚ 120˚ 11315 90˚ 5657 Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower. 60˚ 60˚ 30˚ 0' 20' 40' 60' 80' 100' 120' 140' 160' 180' 24.4 18.3 40' 12.2 20' 6.1 0' 90˚ 20' 60' 20' 2 1 .5 .2 .1 0m Sign Optic Distribution 4000K 5700K Initial Delivered Lumens* Initial Delivered Lumens* 04 4,708 4,889 06 7,007 7,277 04 6,591 6,845 06 9,810 10,187 04 8,004 8,312 06 11,912 12,370 LED Count (x10) 6.1 40' 12.2 60' 18.3 24.4 80' 12.2 6.1 0m 6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 350mA 30˚ RESTL Test Report #: 2014-0013 FLD-EDG-SN-**-06-E-UL-700-40K Initial Delivered Lumens: 11,885 FLD-EDG-SN-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G., 60˚ Tilt Initial Delivered Lumens: 12,370 Initial FC at grade 525mA 700mA * Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens US: lighting.cree.com/lighting T (800) 236-6800 F (262) 504-5415 Canada: www.cree.com/canada T (800) 473-1234 F (800) 890-7507 304 Series™ LED Flood Luminaire Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool N6 150˚ 5287 150˚ -40' -20' 80' 3965 120˚ 120˚ 2643 90˚ 1322 Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower. 60˚ 0' 40' 60' 80' 100' 120' 140' 160' 180' 24.4 18.3 40' 12.2 20' 6.1 0' 90˚ 20' 60' 2 1 .5 .2 0m .1 20' 6.1 40' 12.2 60' 18.3 24.4 80' -12.2 -6.1 0m 6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 60˚ NEMA® 6 Distribution 4000K 5700K Initial Delivered Lumens* Initial Delivered Lumens* 04 5,219 5,419 06 7,767 8,066 04 7,306 7,587 06 10,874 11,292 04 8,872 9,213 06 13,204 13,712 LED Count (x10) 350mA 30˚ 30˚ RESTL Test Report #: 2014-0014 FLD-EDG-N6-**-06-E-UL-700-40K Initial Delivered Lumens: 13,253 FLD-304-N6-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G., 60˚ Tilt Initial Delivered Lumens: 13,712 Initial FC at grade 525mA 700mA * Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens 15˚ 150˚ 91749 -20' 150˚ 68811 120˚ 120˚ 45874 20' 40' 60' 80' 100' 120' 140' 160' 180' 24.4 60' 18.3 40' 12.2 20' 0' 22937 90˚ 90˚ 60˚ 60˚ 30˚ 0' 80' 1 .5 .2 .1 0m 6.1 40' 12.2 60' 18.3 24.4 80' 6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower. RESTL Test Report #: 2014-0004 FLD-EDG-15-**-06-E-UL-700-40K Initial Delivered Lumens: 13,035 4000K 5700K Initial Delivered Lumens* Initial Delivered Lumens* 04 5,219 5,419 06 7,767 8,066 04 7,306 7,587 06 10,874 11,292 04 8,872 9,213 06 13,204 13,712 6.1 2 20' -6.1 0m 15˚ Flood Distribution FLD-304-15-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G., 60˚ Tilt Initial Delivered Lumens: 13,712 Initial FC at grade LED Count (x10) 350mA 525mA 700mA * Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens US: lighting.cree.com/lighting T (800) 236-6800 F (262) 504-5415 Canada: www.cree.com/canada T (800) 473-1234 F (800) 890-7507 304 Series™ LED Flood Luminaire Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool 25˚ 150˚ 35689 -20' 150˚ 26767 120˚ 120˚ 17845 0' 20' 40' 60' 80' 100' 120' 140' 160' 180' 80' 24.4 60' 18.3 40' 12.2 20' 8922 90˚ 1 .5 .2 .1 6.1 40' 12.2 24.4 -6.1 0m 6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower. 30˚ FLD-304-25-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G., 60˚ Tilt Initial Delivered Lumens: 13,712 Initial FC at grade RESTL Test Report #: 2014-0006 FLD-EDG-25-**-06-E-UL-700-40K Initial Delivered Lumens: 12,924 5700K Initial Delivered Lumens* Initial Delivered Lumens* 04 5,219 5,419 06 7,767 8,066 04 7,306 7,587 06 10,874 11,292 04 8,872 9,213 06 13,204 13,712 LED Count (x10) 18.3 80' 60˚ 0m 20' 60' 60˚ 4000K 6.1 2 0' 90˚ 25˚ Flood Distribution 350mA 525mA 700mA * Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens 40˚ 150˚ 16598 -20' 150˚ 12449 120˚ 120˚ 8299 4150 90˚ Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower. 60˚ 90˚ 60˚ 30˚ 0' 20' 40' 60' 80' 100' 120' 140' 160' 180' 80' 24.4 60' 18.3 40' 12.2 20' 6.1 0' 0m 2 1 .5 .2 .1 20' 6.1 40' 12.2 60' 18.3 80' -6.1 0m 24.4 6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 30˚ ITL Test Report #: 78011 CAN-304-40-**-06-E-UL-700-40K Initial Delivered Lumens: 12,497 FLD-304-40-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G., 60˚ Tilt Initial Delivered Lumens: 13,413 Initial FC at grade 40˚ Flood Distribution 4000K 5700K Initial Delivered Lumens* Initial Delivered Lumens* 04 5,105 5,302 06 7,598 7,890 04 7,147 7,422 06 10,637 11,046 04 8,679 9,013 06 12,917 13,413 LED Count (x10) 350mA 525mA 700mA * Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens US: lighting.cree.com/lighting T (800) 236-6800 F (262) 504-5415 Canada: www.cree.com/canada T (800) 473-1234 F (800) 890-7507 304 Series™ LED Flood Luminaire Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool 70˚ 150˚ 3951 -20' 150˚ 2963 120˚ 120˚ 1976 988 90˚ 90˚ 0' 20' 40' 60' 80' 100' 120' 140' 160' 180' 80' 24.4 60' 18.3 40' 12.2 20' 6.1 0' 0m 2 1 .5 .2 .1 20' 6.1 40' 12.2 60' 60˚ 60˚ 30˚ 24.4 6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9 Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower. CESTL Test Report #: 2014-0007 FLD-EDG-70-**-04-E-UL-350-40K Initial Delivered Lumens: 4,734 4000K 5700K Initial Delivered Lumens* Initial Delivered Lumens* 04 4,651 4,830 06 6,923 7,189 04 6,512 6,762 06 9,692 10,064 04 7,907 8,211 06 11,768 12,221 LED Count (x10) 18.3 80' -6.1 0m 70˚ Flood Distribution FLD-304-70-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G., 60˚ Tilt Initial Delivered Lumens: 12,221 Initial FC at grade 350mA 525mA 700mA * Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens ® 2016 Cree, Inc. and/or one of its subsidiries. All rights reserved. For informational purposes only. Content is subject to change. Patent www.cree.com/patents. Cree®, NanoOptic®, and Colorfast DeltaGuard® are registered trademarks, and the Cree logo and 304 Series™ are trademarks of Cree, Inc. The UL logo is a registered trademark of UL LLC. NEMA® is a registered trademark of the National Electrical Manufacturers Association. US: lighting.cree.com/lighting T (800) 236-6800 F (262) 504-5415 Canada: www.cree.com/canada T (800) 473-1234 F (800) 890-7507
Similar documents
Cree Edge™ Series
** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
More informationled recessed soffit light specification sheet
or new construction applications with 16" (406mm) to 24" (610mm) on center building construction. Heavy gauge steel recessed mounting frame features 1-1/2" (38mm) deep aperture throat to accommodat...
More information