Cree 304 Series Flood Luminaire Spec Sheet

Transcription

Cree 304 Series Flood Luminaire Spec Sheet
304 Series™
LED Flood Luminaire
Product Description
Slim, low profile design. Luminaire is constructed from rugged die cast and extruded aluminum
components. LED driver is mounted in a sealed weathertight center chamber that allows for access
from below the luminaire. High performance heat sinks specifically designed for LED floodlight
application. Luminaire mounts with stainless steel adjustable yoke mount which allows for +/- 90˚
adjustment in 5˚ increments.
Applications: Underpasses and sign lighting
12.0" SQ
(305mm)
Performance Summary
Patented NanoOptic® Product Technology
Made in the U.S.A. of U.S. and imported parts
7.3"
(184mm)
CRI: Minimum 70 CRI
CCT: 4000K (+/- 300K), 5700K (+/- 500K) standard
Limited Warranty†: 10 years on luminaire/10 years on Colorfast DeltaGuard® finish
†
See http://lighting.cree.com/warranty for warranty terms
Accessories
Multi-Level
Sensor location
(ordered as an option)
14.5"
(367mm)
Field-Installed
Hand-Held Remote
XA-SENSREM
- For successful implementation of the programmable multi-level option, a minimum of one hand-held remote is required
7.3"
7.8"
(184mm) (197mm)
12.8"
(325mm)
7.5"
(191mm)
Ø0.3"
(8mm)
1.5"
(38mm)
LED Count (x10)
Weight
04
23 lbs. (10.4kg)
06
23 lbs. (10.4kg)
Ordering Information
Example: FLD-304-2M-YM-04-E-UL-SV-350
FLD-304
YM
Product
Optic
FLD-304
2M
Type II Medium
3M
Type III Medium
5M
Type V Medium
5S
Type V Short
N6
NEMA® 6
SL
Sparkle Petroleum
SN
Sign
15
15˚ Flood
25
25˚Flood
40
40˚ Flood
70
70˚Flood
E
Mounting
LED
Count
(x10)
YM
Yoke
04
06
Series
Voltage
E
UL
Universal
120-277V
UH
Universal
347-480V
Color
Options
SV
Silver
BK
Black
BZ
Bronze
WH
White
Drive Current
Options
350
350mA
525
525mA
700
700mA
DIM 0-10V Dimming
-- Control by others
-- Refer to Dimming spec sheet for details
-- Can't exceed specified drive current
FFuse
-- When code dictates fusing, use time delay fuse
-- Refer to ML spec sheet for availability with ML options
-- Available with UL voltage only
MLMulti-Level
-- Refer to ML spec sheet for details
-- Intended for downlight applications at 0˚ tilt
PML Programmable Multi-Level, 10-30' Mounitng Height
-- Refer to PML spec sheet for details
-- Intended for downlight applications at 0˚ tilt
40K 4000K Color Temperature
-- Minimum 70 CRI
-- Color temperature per luminaire
Rev. Date: V3 01/19/2016
US: lighting.cree.com/lighting
T (800) 236-6800 F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234 F (800) 890-7507
304 Series™ LED Flood Luminaire
Product Specifications
Electrical Data*
CONSTRUCTION & MATERIALS
• Slim, low profile design
• Luminaire is constructed from rugged die cast and extruded aluminum components
LED Count
(x10)
• LED driver is mounted in a sealed weathertight center chamber that allows for access
from below the luminaire
350mA
• 3' (0.9m) SEOW cord exits street side of luminaire through 1/2" (13mm) NPT cable
gland
System Watts
120-480V
Total Current
120V
208V
240V
277V
347V
480V
04
46
0.39
0.24
0.22
0.21
0.15
0.12
• High performance aluminum heat sinks specifically designed for LED floodlight
applications
06
69
0.57
0.34
0.30
0.27
0.21
0.16
• Luminaire mounts with stainless steel adjustable yoke which allows for +/- 90˚
adjustment in 5˚ increments
525mA
04
71
0.59
0.35
0.31
0.28
0.21
0.16
06
101
0.84
0.49
0.43
0.38
0.30
0.22
04
94
0.79
0.46
0.40
0.36
0.28
0.21
06
135
1.14
0.65
0.57
0.50
0.40
0.29
• Exclusive Colorfast DeltaGuard finish features an E-Coat epoxy primer with an
ultradurable powder topcoat, providing excellent resistance to corrosion, ultraviolet
degradation and abrasion. Black, bronze, silver, and white are available
®
• Weight: 40 LED: 23 lbs. (10.4kg); 60 LED: 23 lbs. (10.4kg)
700mA
ELECTRICAL SYSTEM
• Input Voltage: 120-277V or 347-480V, 50/60Hz, Class 1 drivers
• Power Factor: > 0.9 at full load
• Total Harmonic Distortion: < 20% at full load
• Integral 10kV surge suppression protection standard
* Electrical data at 25˚C (77˚F). Actual wattage may differ by +/- 10% when operating between 120-480V +/- 10%
• To address inrush current, slow blow fuse or type C/D breaker should be used
• 10V Source Current: 0.15mA
Recommended 304 Series™ Flood Lumen Maintenance Factors (LMF)1
REGULATORY & VOLUNTARY QUALIFICATIONS
• cULus Listed
• Suitable for wet locations
Ambient
Initial
LMF
25K hr
Projected2
LMF
50K hr
Projected2
LMF
75K hr
Calculated3
LM
100K hr
Calculated3
LMF
5˚C (41˚F)
1.04
0.99
0.97
0.95
0.93
10˚C (50˚F)
1.03
0.98
0.96
0.94
0.92
15˚C (59˚F)
1.02
0.97
0.95
0.93
0.91
20˚C (68˚F)
1.01
0.96
0.94
0.92
0.90
25˚C (77˚F)
1.00
0.95
0.93
0.91
0.89
• Enclosure rated IP66 per IEC 60529
• Consult factory for CE Certified products
• Certified to ANSI C136.31-2001, 3G bridge and overpass vibration standards
• 10kV surge suppression protection tested in accordance with IEEE/ANSI C62.41.2
• Luminaire and finish endurance tested to withstand 5,000 hours of elevated ambient
salt fog conditions as defined in ASTM Standard B 117
• Meets Buy American requirements within ARRA
• Meets FCC Part 15, Subpart B, Class A standards for conducted and radiated
emissions
• RoHS compliant. Consult factory for additional details
Lumen maintenance values at 25˚C (77˚F) are calculated per TM-21 based on LM-80 data and in-situ luminaire testing
In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on time durations that are within six times
(6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip)
3
In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times (6X) the IESNA LM-80-08 total
test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip)
1
2
US: lighting.cree.com/lighting
T (800) 236-6800 F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234 F (800) 890-7507
304 Series™ LED Flood Luminaire
Photometry
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project
consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool
2M
150˚
7551
150˚
100' 80' 60' 40' 20'
60'
5663
120˚
120˚
3776
80' 100'
20' 40' 60'
74˚
18.3
90˚
40'
2
0m
6.1
CURB LINE
12.2
60'
0m
Initial
Delivered
Lumens*
BUG
Ratings**
Per TM-15-11
Initial
Delivered
Lumens*
BUG
Ratings**
Per TM-15-11
04
4,368
B1 U0 G1
4,536
B2 U0 G2
06
6,501
B2 U0 G2
6,751
B2 U0 G2
04
6,115
B2 U0 G2
6,350
B2 U0 G2
06
9,101
B3 U0 G3
9,451
B3 U0 G3
04
7,425
B2 U0 G2
7,711
B2 U0 G2
06
11,051
B3 U0 G3
11,476
B3 U0 G3
350mA
Position of vertical plane
of maximum candlepower.
Candlepower Trace: Vertical plane through
30º
horizontal angle of maximum
candlepower.
FLD-304-2M-**-06-E-UL-700
Mounting Height: 25' (7.6m) A.F.G.
Initial Delivered Lumens: 11,476
Initial FC at grade
ITL Test Report #: 77237
STR-LWY-2M-**-06-E-UL-700-40K
Initial Delivered Lumens: 11,094
5700K
6.1 12.2 18.3 24.4 30.5
60˚
30˚
LED Count
(x10)
18.3
30.5 24.4 18.3 12.2 6.1
60˚
4000K
6.1
.1 .2 .5 1
20'
90˚
Type II Medium Distribution
12.2
20'
0'
1888
0'
40'
525mA
700mA
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens
** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit:
www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
3M
150˚
4634
150˚
100'
120˚
120˚
2317
80'
60'
40'
0'
20'
20'
40'
60'
80' 100'
60˚
60'
20'
20'
.5
6.1
1
0m
CURB LINE
6.1
40'
60˚
60˚
Candlepower Trace: Vertical plane through
30º
horizontal angle of maximum
candlepower.
CESTL Test Report #: 2013-0068
STR-LWY-3M-**-06-E-UL-700-40K
Initial Delivered Lumens: 10,430
4000K
LED Count
(x10)
18.3
80'
24.4
0m
6.1
30.5
12.2 18.3 24.4 30.5
Position of vertical plane
of maximum candlepower.
FLD-304-3M-**-06-E-UL-700
Mounting Height: 25' (7.6m) A.F.G.
Initial Delivered Lumens: 10,880
Initial FC at grade
5700K
Initial
Delivered
Lumens*
BUG
Ratings**
Per TM-15-11
Initial
Delivered
Lumens*
BUG
Ratings**
Per TM-15-11
04
4,141
B1 U0 G1
4,300
B1 U0 G1
06
6,163
B2 U0 G2
6,400
B2 U0 G2
04
5,797
B2 U0 G2
6,020
B2 U0 G2
06
8,628
B2 U0 G2
8,960
B2 U0 G2
04
7,039
B2 U0 G2
7,310
B2 U0 G2
06
10,477
B3 U0 G3
10,880
B3 U0 G3
12.2
60'
100'
30.5 24.4 18.3 12.2 6.1
30˚
Type III Medium Distribution
12.2
2
.1 .2
0'
90˚
30.5
24.4
18.3
40'
1159
90˚
100'
80'
3476
350mA
525mA
700mA
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens
** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit:
www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
US: lighting.cree.com/lighting
T (800) 236-6800 F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234 F (800) 890-7507
304 Series™ LED Flood Luminaire
Photometry
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project
consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool
5M
150˚
3892
150˚
100'
100'
80'
60'
40'
20'
0'
40'
20'
60'
80' 100'
0˚
80'
2919
120˚
120˚
1946
18.3
40'
12.2
20'
973
.1 .2
.5
0'
90˚
90˚
20'
6.1
1
0m
CURB LINE
6.1
40'
60˚
60˚
30˚
Type V Medium Distribution
4000K
LED Count
(x10)
18.3
80'
24.4
100'
30.5 24.4 18.3 12.2 6.1
0m
6.1
30.5
12.2 18.3 24.4 30.5
Position of vertical plane
of maximum candlepower.
FLD-304-5M-**-06-E-UL-700
Mounting Height: 25' (7.6m) A.F.G.
Initial Delivered Lumens: 12,072
Initial FC at grade
5700K
Initial
Delivered
Lumens*
BUG
Ratings**
Per TM-15-11
Initial
Delivered
Lumens*
BUG
Ratings**
Per TM-15-11
04
4,595
B3 U0 G1
4,771
B3 U0 G1
06
6,838
B3 U0 G2
7,101
B3 U0 G2
04
6,433
B3 U0 G2
6,680
B3 U0 G2
06
9,574
B3 U0 G2
9,942
B3 U0 G2
04
7,811
B3 U0 G2
8,111
B3 U0 G2
06
11,625
B4 U0 G2
12,072
B4 U0 G2
12.2
60'
Candlepower Trace: Vertical plane through
horizontal angle of maximum
30ºcandlepower.
ITL Test Report #: 78147
PKG-304-5M-**-06-E-UL-700
Initial Delivered Lumens: 12,508
30.5
24.4
60'
350mA
525mA
700mA
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens
** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit:
www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
5S
150˚
4941
100'
150˚
100' 80' 60' 40' 20'
120˚
120˚
0' 20' 40' 60' 80' 100'
30.5
45˚
80'
3706
6.1
20'
1235
0'
90˚
90˚
20'
1 .2 .5 1
0m
CURB LINE
60˚
30˚
Candlepower Trace: Vertical plane through
horizontal angle of maximum candlepower.
ITL Test Report #: 77876
PKG-304-5S-**-06-E-UL-700-40K
Initial Delivered Lumens: 12,738
4000K
6.1
LED Count
(x10)
60'
18.3
80'
24.4
100'
30.5
30.5 24.4 18.3 12.2 6.1 0m 6.1 12.2 18.3 24.4 30.5
Position of vertical plane
of maximum candlepower.
FLD-304-5S-**-06-E-UL-700
Mounting Height: 25' (7.6m) A.F.G.
Initial Delivered Lumens: 13,413
Initial FC at grade
5700K
Initial
Delivered
Lumens*
BUG
Ratings**
Per TM-15-11
Initial
Delivered
Lumens*
BUG
Ratings**
Per TM-15-11
04
5,105
B2 U0 G1
5,302
B2 U0 G1
06
7,598
B3 U0 G1
7,890
B3 U0 G1
04
7,147
B3 U0 G1
7,422
B3 U0 G1
06
10,637
B3 U0 G2
11,046
B3 U0 G2
04
8,679
B3 U0 G1
9,013
B3 U0 G1
06
12,917
B3 U0 G2
13,413
B3 U0 G2
12.2
40'
60˚
Type V Short Distribution
12.2
40'
2471
24.4
18.3
60'
350mA
525mA
700mA
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens
** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit:
www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
US: lighting.cree.com/lighting
T (800) 236-6800 F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234 F (800) 890-7507
304 Series™ LED Flood Luminaire
Photometry
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project
consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool
SL
150˚
4444
100'
150˚
100' 80' 60' 40' 20'
0' 20' 40' 60' 80' 100'
30.5
80'
3333
120˚
120˚
2222
1111
Candlepower Trace: Vertical plane through
horizontal angle of maximum candlepower.
60˚
.2
4000K
6.1
.5 1 2
LED Count
(x10)
0m
CURB LINE
6.1
60'
18.3
80'
24.4
Position of vertical plane
of maximum candlepower.
FLD-304-SL-**-06-E-UL-700
Mounting Height: 25' (7.6m) A.F.G.
Initial Delivered Lumens: 13,264
Initial FC at grade
ITL Test Report #: 77415
CAN-304-SL-**-06-E-UL-700-40K
Initial Delivered Lumens: 12,707
BUG
Ratings**
Per TM-15-11
Initial
Delivered
Lumens*
BUG
Ratings**
Per TM-15-11
04
5,048
B2 U0 G1
5,243
B2 U0 G1
06
7,514
B3 U0 G1
7,803
B3 U0 G1
04
7,068
B2 U0 G1
7,340
B2 U0 G1
06
10,519
B3 U0 G1
10,924
B3 U0 G1
04
8,582
B3 U0 G1
8,912
B3 U0 G1
06
12,773
B3 U0 G1
13,264
B3 U0 G1
350mA
100'
30.5
30.5 24.4 18.3 12.2 6.1 0m 6.1 12.2 18.3 24.4 30.5
30˚
5700K
Initial
Delivered
Lumens*
12.2
40'
60˚
30˚
.1
0'
20'
90˚
18.3
12.2
40'
20'
90˚
Sparkle Petroleum Distribution
24.4
45˚
60'
525mA
700mA
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens
** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit:
www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
SN
150˚
22629
150˚
40'
80'
16972
120˚
120˚
11315
90˚
5657
Candlepower Trace: Vertical plane through
horizontal angle of maximum candlepower.
60˚
60˚
30˚
0'
20'
40' 60' 80' 100' 120' 140' 160' 180'
24.4
18.3
40'
12.2
20'
6.1
0'
90˚
20'
60'
20'
2
1 .5
.2 .1
0m
Sign Optic Distribution
4000K
5700K
Initial
Delivered
Lumens*
Initial
Delivered
Lumens*
04
4,708
4,889
06
7,007
7,277
04
6,591
6,845
06
9,810
10,187
04
8,004
8,312
06
11,912
12,370
LED Count
(x10)
6.1
40'
12.2
60'
18.3
24.4
80'
12.2 6.1 0m 6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9
350mA
30˚
RESTL Test Report #: 2014-0013
FLD-EDG-SN-**-06-E-UL-700-40K
Initial Delivered Lumens: 11,885
FLD-EDG-SN-**-06-E-UL-700
Mounting Height: 25' (7.6m) A.F.G., 60˚ Tilt
Initial Delivered Lumens: 12,370
Initial FC at grade
525mA
700mA
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens
US: lighting.cree.com/lighting
T (800) 236-6800 F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234 F (800) 890-7507
304 Series™ LED Flood Luminaire
Photometry
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project
consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool
N6
150˚
5287
150˚
-40' -20'
80'
3965
120˚
120˚
2643
90˚
1322
Candlepower Trace: Vertical plane through
horizontal angle of maximum candlepower.
60˚
0'
40' 60' 80' 100' 120' 140' 160' 180'
24.4
18.3
40'
12.2
20'
6.1
0'
90˚
20'
60'
2 1 .5
.2
0m
.1
20'
6.1
40'
12.2
60'
18.3
24.4
80'
-12.2 -6.1 0m 6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9
60˚
NEMA® 6 Distribution
4000K
5700K
Initial
Delivered
Lumens*
Initial
Delivered
Lumens*
04
5,219
5,419
06
7,767
8,066
04
7,306
7,587
06
10,874
11,292
04
8,872
9,213
06
13,204
13,712
LED Count
(x10)
350mA
30˚
30˚
RESTL Test Report #: 2014-0014
FLD-EDG-N6-**-06-E-UL-700-40K
Initial Delivered Lumens: 13,253
FLD-304-N6-**-06-E-UL-700
Mounting Height: 25' (7.6m) A.F.G., 60˚ Tilt
Initial Delivered Lumens: 13,712
Initial FC at grade
525mA
700mA
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens
15˚
150˚
91749
-20'
150˚
68811
120˚
120˚
45874
20'
40'
60'
80'
100' 120' 140' 160' 180'
24.4
60'
18.3
40'
12.2
20'
0'
22937
90˚
90˚
60˚
60˚
30˚
0'
80'
1 .5
.2
.1
0m
6.1
40'
12.2
60'
18.3
24.4
80'
6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9
Candlepower Trace:
Vertical plane through
horizontal angle of
maximum candlepower.
RESTL Test Report #: 2014-0004
FLD-EDG-15-**-06-E-UL-700-40K
Initial Delivered Lumens: 13,035
4000K
5700K
Initial
Delivered
Lumens*
Initial
Delivered
Lumens*
04
5,219
5,419
06
7,767
8,066
04
7,306
7,587
06
10,874
11,292
04
8,872
9,213
06
13,204
13,712
6.1
2
20'
-6.1 0m
15˚ Flood Distribution
FLD-304-15-**-06-E-UL-700
Mounting Height: 25' (7.6m) A.F.G., 60˚ Tilt
Initial Delivered Lumens: 13,712
Initial FC at grade
LED Count
(x10)
350mA
525mA
700mA
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens
US: lighting.cree.com/lighting
T (800) 236-6800 F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234 F (800) 890-7507
304 Series™ LED Flood Luminaire
Photometry
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project
consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool
25˚
150˚
35689
-20'
150˚
26767
120˚
120˚
17845
0'
20'
40'
60'
80'
100' 120' 140' 160' 180'
80'
24.4
60'
18.3
40'
12.2
20'
8922
90˚
1
.5
.2
.1
6.1
40'
12.2
24.4
-6.1 0m
6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9
Candlepower Trace:
Vertical plane through
horizontal angle of
maximum candlepower.
30˚
FLD-304-25-**-06-E-UL-700
Mounting Height: 25' (7.6m) A.F.G., 60˚ Tilt
Initial Delivered Lumens: 13,712
Initial FC at grade
RESTL Test Report #: 2014-0006
FLD-EDG-25-**-06-E-UL-700-40K
Initial Delivered Lumens: 12,924
5700K
Initial
Delivered
Lumens*
Initial
Delivered
Lumens*
04
5,219
5,419
06
7,767
8,066
04
7,306
7,587
06
10,874
11,292
04
8,872
9,213
06
13,204
13,712
LED Count
(x10)
18.3
80'
60˚
0m
20'
60'
60˚
4000K
6.1
2
0'
90˚
25˚ Flood Distribution
350mA
525mA
700mA
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens
40˚
150˚
16598
-20'
150˚
12449
120˚
120˚
8299
4150
90˚
Candlepower Trace: Vertical plane through
horizontal angle of maximum candlepower.
60˚
90˚
60˚
30˚
0'
20'
40'
60'
80'
100' 120' 140' 160' 180'
80'
24.4
60'
18.3
40'
12.2
20'
6.1
0'
0m
2
1
.5
.2
.1
20'
6.1
40'
12.2
60'
18.3
80'
-6.1 0m
24.4
6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9
30˚
ITL Test Report #: 78011
CAN-304-40-**-06-E-UL-700-40K
Initial Delivered Lumens: 12,497
FLD-304-40-**-06-E-UL-700
Mounting Height: 25' (7.6m) A.F.G., 60˚ Tilt
Initial Delivered Lumens: 13,413
Initial FC at grade
40˚ Flood Distribution
4000K
5700K
Initial
Delivered
Lumens*
Initial
Delivered
Lumens*
04
5,105
5,302
06
7,598
7,890
04
7,147
7,422
06
10,637
11,046
04
8,679
9,013
06
12,917
13,413
LED Count
(x10)
350mA
525mA
700mA
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens
US: lighting.cree.com/lighting
T (800) 236-6800 F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234 F (800) 890-7507
304 Series™ LED Flood Luminaire
Photometry
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project
consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool
70˚
150˚
3951
-20'
150˚
2963
120˚
120˚
1976
988
90˚
90˚
0'
20'
40'
60'
80'
100' 120' 140' 160' 180'
80'
24.4
60'
18.3
40'
12.2
20'
6.1
0'
0m
2
1
.5
.2
.1
20'
6.1
40'
12.2
60'
60˚
60˚
30˚
24.4
6.1 12.2 18.3 24.4 30.5 36.6 42.7 48.8 54.9
Candlepower Trace:
Vertical plane
through horizontal
angle of maximum
candlepower.
CESTL Test Report #: 2014-0007
FLD-EDG-70-**-04-E-UL-350-40K
Initial Delivered Lumens: 4,734
4000K
5700K
Initial
Delivered
Lumens*
Initial
Delivered
Lumens*
04
4,651
4,830
06
6,923
7,189
04
6,512
6,762
06
9,692
10,064
04
7,907
8,211
06
11,768
12,221
LED Count
(x10)
18.3
80'
-6.1 0m
70˚ Flood Distribution
FLD-304-70-**-06-E-UL-700
Mounting Height: 25' (7.6m) A.F.G., 60˚ Tilt
Initial Delivered Lumens: 12,221
Initial FC at grade
350mA
525mA
700mA
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens
® 2016 Cree, Inc. and/or one of its subsidiries. All rights reserved. For informational purposes only. Content is subject to change.
Patent www.cree.com/patents. Cree®, NanoOptic®, and Colorfast DeltaGuard® are registered trademarks, and the Cree logo and
304 Series™ are trademarks of Cree, Inc. The UL logo is a registered trademark of UL LLC. NEMA® is a registered trademark of the
National Electrical Manufacturers Association.
US: lighting.cree.com/lighting
T (800) 236-6800 F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234 F (800) 890-7507

Similar documents

Cree Edge™ Series

Cree Edge™ Series ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt

More information

led recessed soffit light specification sheet

led recessed soffit light specification sheet or new construction applications with 16" (406mm) to 24" (610mm) on center building construction. Heavy gauge steel recessed mounting frame features 1-1/2" (38mm) deep aperture throat to accommodat...

More information