c1b3658-especificaciones_conexion_al_SITR
Transcription
c1b3658-especificaciones_conexion_al_SITR
ESPECIFICACIONES DE CONEXIÓN PARA EL ENVÍO DE DATOS AL SITR DEL CDC DIRECCIÓN DE OPERACIÓN ÍNDICE 1. 2. 2.1. INTRODUCCIÓN....................................................................................... 3 REQUERIMIENTOS PARA EL REPORTE DE INFORMACIÓN ........................... 3 EQUIPOS DE ADQUISICIÓN DE DATOS...................................................... 3 2.2. ENLACES Y PROTOCOLOS DE COMUNICACIONES ....................................... 3 2.3. 2.2.1. 2.2.2. Protocolo TCP/IP .................................................................................. 3 Protocolo Serial .................................................................................... 4 EQUIPOS DE RED ASOCIADOS A UN ENLACE TCP/IP .................................. 4 2.4. EQUIPOS DE RED ASOCIADOS A UN ENLACE SERIAL.................................. 5 2.5. INFORMACIÓN A TRANSMITIR AL SITR DEL CDEC-SIC ............................... 5 2.6. ACCESO E INSTALACIÓN DE EQUIPOS Y VÍAS DE COMUNICACIÓN EN DEPENDENCIAS DEL CDEC-SIC ................................................................. 5 2.7. 2.8. PRUEBAS DE PUESTA EN SERVICIO........................................................... 6 2.7.1. 2.7.2. 2.7.3. Prueba de Enlace:................................................................................. 6 Prueba Inicial: ...................................................................................... 6 Prueba Punto a Punto: .......................................................................... 6 COSTOS estimados INVOLUCRADOS.......................................................... 7 2.8.1. Hosting ................................................................................................ 7 2.8.2. Modificación Base de Datos SCADA CDEC-SIC ......................................... 7 2.8.3. Protocolo Serial: Dispositivo “Mode ShaRE DEVICES” ............................... 7 2.8.4. Protocolo ICCP: LICENCIA SPECTRUM .................................................... 8 ANEXO 1.- CONFIGURACIÓN ENLACE TCP/IP ..............................................................10 ANEXO 2.PROTOCOLO ICCP: EJEMPLO CONFIGURACIÓN TABLAS BILATERALES ....11 ANEXO 3.CONFIGURACIÓN ENLACE SERIAL ........................................................14 ANEXO 4.PROTOCOLOS IEC 870-5-104/101 Y DNP3.0 TCP-IP/SERIAL: PERFILES ...15 ANEXO 5 PROTOCOLOS IEC 870-5-101 Y DNP3.0 SERIAL: DISPOSITIVO DERIVADOR 19 CDEC-SIC Dirección de Operación Mayo de 2007 1. INTRODUCCIÓN El presente documento complementa el Procedimiento DO “Definición de parámetros técnicos y para el envío de datos al SITR del CDEC-SIC” y especifica las condiciones técnicas y administrativas para la conexión de los Coordinados al SITR del CDC. 2. REQUERIMIENTOS PARA EL REPORTE DE INFORMACIÓN 2.1. EQUIPOS DE ADQUISICIÓN DE DATOS El coordinado deberá seleccionar su equipo de adquisición de datos y/o sistema de reporte, dependiendo del número de señales a reportar al SITR del CDEC-SIC. Esta definición es relevante a la hora de informar al CDEC-SIC el protocolo de transmisión de datos y para seleccionar el ancho de banda o velocidad de transmisión de su(s) enlace(s). 2.2. ENLACES Y PROTOCOLOS DE COMUNICACIONES Dependiendo de la transmisión de datos que el coordinado seleccione, el coordinado deberá instalar, ya sea con equipamiento propio o contratado, los sistemas del enlace de comunicaciones requeridos para cumplir con la disponibilidad de la información especificada en la NTSyCS. 2.2.1. PROTOCOLO TCP/IP En el caso de que la transmisión de datos sea a través de un enlace TCP/IP, el protocolo y ancho de banda deberán ser: Protocolo DNP 3.0 TCP/IP IEC 870-5-104 Ancho de Banda 128 kbps o Superior 128 kbps o Superior En el caso que se defina el intercambio de información entre centros de control, el protocolo deberá ser ICCP sobre TCP/IP. Protocolo ICCP TCP/IP Ancho de Banda 128 kbps o Superior El enlace principal que el coordinado establezca entre sus instalaciones y el front end del CDEC-SIC, deberá llegar a las instalaciones del CPD de Synapsis ubicado en Av. Eduardo Frei Montalva 2205 (ex Panamericana Norte), comuna de Independencia, Santiago. En el caso de que el coordinado determine utilizar en forma adicional un enlace de respaldo, el segundo enlace deberá llegar a las instalaciones del CPD de Especificaciones de conexión al SITR del CDEC-SIC 3 de 19 CDEC-SIC Dirección de Operación Mayo de 2007 Synapsis, ubicado en Santa Rosa 76, primer subterráneo, comuna de Santiago, Santiago. 2.2.2. PROTOCOLO SERIAL En el caso de que la transmisión de datos sea a través de una RTU (serial), el protocolo y ancho de banda deberán ser: Protocolo DNP 3.0 Serial IEC 870-5-101 Ancho de Banda 1.200, 9.600 ó 19.200 baudios 1.200, 9.600 ó 19.200 baudios El enlace que el coordinado establezca entre sus instalaciones y el Front-End del CDEC-SIC, deberá llegar a las instalaciones del CPD de Synapsis ubicado en Av. Eduardo Frei Montalva 2205 (ex Panamericana Norte), comuna de Independencia, Santiago. 2.3. EQUIPOS DE RED ASOCIADOS A UN ENLACE TCP/IP En el caso de tratarse de una conexión de red Ethernet, la conectividad entre los equipos será habilitada y validada por las dos partes en conjunto, tanto por el coordinado como por el CDEC-SIC a través de Synapsis. Como paso previo a esta habilitación, el coordinado entregará un esquema de red con las direcciones IP y rutas que deben ser configuradas y el CDEC-SIC lo complementará con sus propios equipos, direcciones y rutas. En base a esta información, el CDEC-SIC generará un diagrama unificado con los equipos de ambos, el cual considerará dispositivos intermedios y cortafuegos que sean requeridos para establecer la conectividad. En el ANEXO 1 se muestra un ejemplo que describe un diagrama esquemático de redes con los principales elementos que componen un enlace TCP/IP entre el CDECSIC y un coordinado. En él se indican las direcciones IP necesarias de los servidores Front-End (TCS) e ICCP (UCS) del Sistema SIEMENS SPECTRUM del CDEC-SIC, así como el firewall y el Switch de redes externas. Además se muestran los equipos de comunicaciones que integran este enlace. En el ANEXO 4 se encuentran los perfiles de los protocolos TCP/IP IEC 870-5-104 y DNP 3.0. Específicamente para el protocolo ICCP, en el ANEXO 2 se encuentra un ejemplo de la configuración y parámetros de las tablas bilaterales que deben ser dispuestas en los servidores de los centros de control. Para el caso de un enlace TCP/IP, el CDEC-SIC indicará al coordinado el punto del “Switch de Redes Externas” del SCADA del CDEC-SIC donde deberá conectar un cable con extremo RJ-45. Especificaciones de conexión al SITR del CDEC-SIC 4 de 19 CDEC-SIC Dirección de Operación 2.4. Mayo de 2007 EQUIPOS DE RED ASOCIADOS A UN ENLACE SERIAL En el caso de tratarse de una conexión serial, la conectividad entre los equipos será habilitada y validada por las dos partes en conjunto, tanto por el coordinado como por el CDEC-SIC a través de Synapsis. Como paso previo a esta habilitación, el coordinado entregará un esquema de comunicaciones y definición de parámetros de los equipos RTU y el CDEC-SIC lo complementará con sus propios equipos, direcciones y rutas. En base a esta información, el CDEC-SIC generará un diagrama unificado con los equipos de ambos, el cual considerará los dispositivos que conformarán la conectividad. En el ANEXO 3 se muestra un ejemplo que describe un diagrama esquemático de comunicación con los principales elementos que componen un enlace serial entre el CDEC-SIC y un coordinado. En el ANEXO 4 se encuentran los perfiles de los protocolos Seriales referidos. En el caso de una conexión vía RTU en protocolo DNP 3.0 Serial o IEC 870-5-101, el CDEC-SIC indicará al coordinado el punto del “Front-End del SCADA” del CDEC-SIC donde deberá conectar un cable DB-25. A su vez, el coordinado deberá considerar un dispositivo derivador denominado “Modem Sharing Device” que permite utilizar la redundancia del Front-End del Sistema SCADA del CDEC-SIC. En el ANEXO 5 se presenta la descripción técnica del dispositivo y el pin-out del Terminal DB-25 necesario. 2.5. INFORMACIÓN A TRANSMITIR AL SITR DEL CDEC-SIC De acuerdo a lo especificado en el PROCEDIMIENTO DO “DEFINICIÓN DE PARÁMETROS TÉCNICOS Y OPERATIVOS PARA EL ENVÍO DE DATOS AL SITR DEL CDC”, el coordinado deberá informar al CDEC-SIC el listado de variables que reportará y transmitirá al Sistema SIEMENS SPECTRUM del CDEC-SIC. 2.6. ACCESO E INSTALACIÓN DE EQUIPOS Y VÍAS DE COMUNICACIÓN EN DEPENDENCIAS DEL CDEC-SIC En el caso de que el coordinado requiera instalar equipos en dependencias del CDECSIC para habilitar una vía de comunicación, deberá tener presente lo siguiente: La administración de los servicios de SITR del CDEC-SIC, se realizan a través de un contrato de outsourcing con SYNAPSIS IT LTDA, esto significa que los equipos deberán instalarse en un CPD de dicha empresa, ubicado en Panamericana Norte 2205, comuna de Independencia; y en caso de utilizar la redundancia (sólo para enlace TCP/IP) deberán instalarse en el CPD de Synapsis IT LTDA., ubicado en Santa Rosa 76, comuna de Santiago. Especificaciones de conexión al SITR del CDEC-SIC 5 de 19 CDEC-SIC Dirección de Operación Mayo de 2007 Todas las instalaciones de equipamiento tienen soporte de gabinetes, llegada de comunicaciones, electricidad con sistemas de respaldo, sistemas de extinción de incendios y atención de operadores ante fallas. Toda instalación de equipos en el CPD de Synapsis está con contrato de servicios, cuya prestación del servicio de hosting y Mantenimiento tiene un costo para el coordinado. Antes de instalar un equipo en el CPD, el coordinado deberá contactar, por lo menos con dos días de antelación, a don Alvaro Olguin Bruna ([email protected]) o Jorge Silva Escobar ([email protected]), ambos de Synapsis, fono: 02- 397 66 00, Anexos: [68 65] – [67 42] – [68 94], solicitando autorización de ingreso al CPD de Synapsis para efectuar instalación de equipos. Además, el coordinado deberá proveer la siguiente información con 24 horas de antelación. - Nombre y Rut del personal que ingresarán al CPD. Empresa a la que pertenecen. Motivo del ingreso. Día y Hora en que se realizarán los trabajos. Con esta información, Synapsis gestionará los permisos correspondientes para que el coordinado pueda ingresar al CPD y efectuar sus trabajos. 2.7. PRUEBAS DE PUESTA EN SERVICIO Para el programa de pruebas para la puesta en servicio se debe seguir el siguiente procedimiento: 2.7.1. PRUEBA DE ENLACE: A nivel de capa de enlace se debe constatar que los equipos comuniquen verificando rutas y permisos de los sistemas. 2.7.2. PRUEBA INICIAL: Se configuran en ambos centros una Base de Datos reducida de Prueba a concensuar entre el CDEC-SIC y el coordinado. Se revisa que todos los cambios de las variables transferidas se procesen en forma correcta en el SCADA del CDEC-SIC. 2.7.3. PRUEBA PUNTO A PUNTO: Especificaciones de conexión al SITR del CDEC-SIC 6 de 19 CDEC-SIC Dirección de Operación Mayo de 2007 Se configuran en ambos centros la Base de Datos definitiva y se realizan los cambios de todas las variables que envía el coordinado. 2.8. 2.8.1. COSTOS ESTIMADOS INVOLUCRADOS HOSTING Representa un Costo Fijo mínimo un (1) Año y prorrogable automáticamente por el mismo periodo. El concepto de este costo es de utilización de espacio en gabinete, energía con sistemas de respaldo, llegada de comunicaciones, sistemas de extinción de incendios, atención operadores y gestión de accesos. El valor por unidad de espacio “u” durante un año es de UF 25,0. Este costo debe quedar suscrito mediante “Contrato de Servicios de Hosting” con Synapsis IT Ltda. 2.8.2. MODIFICACIÓN BASE DE DATOS SCADA CDEC-SIC Representa un Costo Variable hacia Synapsis IT Ltda., como administrador de la plataforma SCADA Spectrum del CDEC-SIC. El costo depende del número de datos que se deben integrar en el sistema SCADA. Se utilizarán precios históricos de implementaciones similares y que están en conocimiento por parte del CDEC-SIC. En la siguiente tabla se indican precios de acuerdo al número de Tags: Alcance General Servicios Configuración Tablas Interfaz Pruebas: Integración Enlace Transmisión de Datos Desarrollo Base de Datos: SCADA Histórica Modelo Aplicaciones Pruebas Punto a Punto TOTAL UF - Número de Tags N ≤ 25 25 < N ≤ 50 50 < N ≤ 80 80 < N ≤ 120 120 < N 6 6 6 6 6 10 12 14 20 28 25 40 68 84 Revisar Caso a Caso 8 10 14 22 49 68 102 132 Revisar Caso a Caso Revisar Caso a Caso Precios sujetos a revisión y con fines presupuestarios. Plazos de Ejecución: 3 semanas una vez aceptada la oferta. Garantía: 2 meses, después de la puesta en servicio. No incluye ningún equipo hardware, Licencia, ni enlace de comunicaciones. Se debe agregar 10% de administración. Los precios no incluyen IVA. 2.8.3. PROTOCOLO SERIAL: DISPOSITIVO “MODE SHARE DEVICES” Representa un Costo de Activación para el coordinado que decida comunicar con protocolos seriales (IEC 870-5-101 y DNP3.0 serial). Consiste en un dispositivo de comunicaciones que permite obtener redundancia en el Front-End concentrador de comunicaciones del CDEC-SIC (ver esquema ANEXO 3 y especificaciones en ANEXO 5). Este dispositivo es suministrado por Synapsis y tiene un costo estimado de: USD$ 260.- Especificaciones de conexión al SITR del CDEC-SIC 7 de 19 CDEC-SIC Dirección de Operación 2.8.4. Mayo de 2007 PROTOCOLO ICCP: LICENCIA SPECTRUM Representa un Costo de Activación para el coordinado que decida comunicar con protocolo ICCP. Consiste en una licencia de conectividad y habilitación lógica en el sistema SCADA Spectrum del CDEC-SIC. El costo estimado de la licencia es de: USD$ 7.850.- NOTA IMPORTANTE: Protocolo IEC104 MAESTRO El Coordinado debe tener en consideración que el front-end IEC104 del SCADA del CDEC-SIC es un servidor Maestro, esperando de forma estándar iniciar la comunicación con una RTU. En caso de que el Coordinado requiera conectar un equipo concentrador (como un sistema de control numérico), debe solicitar una reunión técnica con los especialistas de Synapsis para valorizar dicha integración. Especificaciones de conexión al SITR del CDEC-SIC 8 de 19 CDEC-SIC Dirección de Operación Mayo de 2007 ANEXOS ANEXO 1.- CONFIGURACIÓN ENLACE TCP/IP ANEXO 2.- PROTOCOLO ICCP: EJEMPLO CONFIGURACIÓN TABLAS BILATERALES ANEXO 3.- CONFIGURACIÓN ENLACE SERIAL ANEXO 4.- PROTOCOLOS IEC 870-5-104/101 Y DNP3.0 TCP-IP/SERIAL: PERFILES ANEXO 5.- PROTOCOLOS IEC 870-5-101 Y DNP3.0 SERIAL: DISPOSITIVO DERIVADOR Especificaciones de conexión al SITR del CDEC-SIC 9 de 19 CDEC-SIC Dirección de Operación Mayo de 2007 ANEXO 1.- CONFIGURACIÓN ENLACE TCP/IP Red SCADA Coordinado OPCIONES: IP UTR IEC104 Coordinado: AA.BB.CC.DD IP UTR DNP3.0 Coordinado: AA.BB.CC.DD IP Servidor ICCP Coordinado: AA.BB.CC.DD IP router lado LAN: AA.BB.CC.EE Router Enlace de Comunicación 128 kbps o superior IP router Lado WAN: FF.GG.HH.JJ IP router lado WAN: FF.GG.KK.LL SCADA CDEC-SIC Instalaciones CPD Synapsis Router CPD Principal: IP router lado LAN: 10.39.XX.YY Edo. Frei Montalva 2205, Comuna Independencia, Santiago Switch Redes Externas Firewall: 10.39.XX.ZZ IP(gateway) que resuelve acceso a servidores ICCP del CDEC-SIC para SCADA del COORDINADO CPD Respaldo: Santa Rosa 76, Comuna Santiago, Santiago Firewall SCADA LAN A LAN B UCS1 LAN A: 10.39.8.9 UCS1 LAN B: 10.39.12.9 UCS2 LAN A: 10.39.8.10 UCS2 LAN B: 10.39.12.10 TCS1 LAN A: 10.39.8.15 TCS1 LAN B: 10.39.12.15 UCS1 TCS2 LAN A: 10.39.8.16 TCS2 LAN B: 10.39.12.16 TCS1 UCS2 TCS2 Notas: TCS: Tele-Control Server. Corresponde al servidor Front-End del sistema SCADA Spectrum de SIEMENS del CDEC-SIC. UCS: Utility Communication Server. Corresponde al servidor ICCP del sistema SCADA Spectrum de SIEMENS del CDEC-SIC. Firewall: Para ICCP se habilitará “port 102” TCP. Para DNP3.0 se habilitará “port 20.000” TCP. Para IEC104 “port” TCP a definir Especificaciones de conexión al SITR del CDEC-SIC 10 de 19 CDEC-SIC Dirección de Operación ANEXO 2.- Mayo de 2007 PROTOCOLO ICCP: EJEMPLO CONFIGURACIÓN TABLAS BILATERALES En el caso de un enlace ICCP, el CDEC-SIC indicará al coordinado el nombre lógico del enlace, nombre de los grupos de datos e identificador de los puntos que serán transmitidos. Asimismo, informará direcciones IP, lado iniciador del enlace y los parámetros que se requieran para establecer la comunicación. La definición de los parámetros de configuración para un enlace ICCP se hace a través de un documento que el CDEC-SIC entregará al coordinado y que contiene la configuración de las tablas bilaterales, junto con la definición del resto de los parámetros de red que ICCP necesita para la configuración de los servidores (selectores Tsel, Psel, etc.). Con esta información, el coordinado deberá aplicarla en su servidor ICCP. Ejemplo Tabla Bilateral ICCP: Central RALCO. Información general del Enlace Un solo enlace de Datos Bidireccional Parámetro Nombre del sistema SCADA CDEC-SIC Nombre del Centro de Control SCADA CDEC-SIC Número Máximo de Transfer Sets Número Máximo de Data Sets Tamaño Máximo de Mensajes MMS Bloques MMS soportados Nombre del Remoto (mirado desde SCADA CDEC-SIC) Nombre del Centro de Control Remoto (mirado desde SCADA CDECSIC) Iniciador de Requerimiento de Asociación Time Out del Requerimiento de Asociación Reintento de Requerimiento de Asociación Time Out del Reintento de Requerimiento de Asociación Versión de la Tabla Bilateral Versión del ICCP Nombre del Dominio Local (mirado desde SCADA CDEC-SIC) Nombre del Dominio Remoto (mirado desde SCADA CDEC-SIC) Nombre del LINK Número del Canal Nombre del AR Local Nombre del AR Remoto Primario Nombre del AR Remoto Alternativo Especificaciones de conexión al SITR del CDEC-SIC Valor ICCP MCS 400 400 15000 1y2 COORDINA RALCO _DOMAIN SCADA CDEC-SIC 18 seg. 8 seg. 10 seg. SYNAPSIS 1996-08 DOMAIN_ COORDINA DOMAIN_MCS COORDINA 11 LOCAL_ COORDINA REMOTE_ COORDINA 11 de 19 CDEC-SIC Dirección de Operación Mayo de 2007 Datos a adquirir por parte del SCADA CDEC-SIC como cliente Información del grupo de datos reportados por excepción y con transmisión de la estampa de tiempo Tipo de Dato: Data_StateExtended Parámetro Nombre del Grupo Reporte Periódico de Datos Reporte por Excepción de Datos Intervalo de Chequeo de Integridad Valor Excpt_1 No Aplica Sí 600 seg. Información del Grupo de Datos Reportados Periódicamente Tipo de Dato: Data_RealQ Parámetro Nombre del Grupo Reporte Periódico de Datos Reporte por Excepción de Datos Periodicidad del Reporte de Datos Especificaciones de conexión al SITR del CDEC-SIC Valor Perio_1 Sí No Aplica 10 seg. 12 de 19 CDEC-SIC Dirección de Operación Mayo de 2007 Valores de Conexión o Selectores (Sacado del archivo de configuración del SCADA del CDEC-SIC) Definición del local: Begin_Local Common_Name AP_Title AP_InvokeID AE_Qualifier AE_InvokeID Psel Ssel Tsel Subnet QOS End_Local = LOCAL_COORDINA = 1 2 50 18 = 100 =2 =1 = 00000068 = 0001 = 0001 =0 =0 Definición del remoto: Begin_Remote Common_Name AP_Title AP_InvokeID AE_Qualifier AE_InvokeID Psel Ssel Tsel Subnet QOS IP_ADDRESS Transport End_Remote = REMOTE_ COORDINA = 1 2 50 18 = 100 =2 =1 = 00000068 = 0001 = 0001 =0 =0 = ip servidor ICCP del COORDINADO = TCP Especificaciones de conexión al SITR del CDEC-SIC 13 de 19 CDEC-SIC Dirección de Operación Mayo de 2007 ANEXO 3.- CONFIGURACIÓN ENLACE SERIAL Red SCADA Coordinado UTR IEC101 y/o DNP3.0 Serial Coordinado: Enlace de Comunicación 128 kbps o superior Nombre UTR: “SE Chile” / “Central Chile” Dirección Física: AA Dirección Lógica: BB SCADA CDEC-SIC Dispositivo Comunicaciones Por ejemplo: Módem Instalaciones CPD Synapsis CPD Principal: Edo. Frei Montalva 2205, Comuna Independencia, Santiago Dispositivo Derivador RAN1 RAN2 LAN A LAN B TCS1 TCS2 Notas: TCS: Tele-Control Server. Corresponde al servidor Front-End del sistema SCADA Spectrum de SIEMENS del CDEC-SIC. RAN: Remote Asynchronous Node. Corresponde al Switch Concentrador de Comunicaciones del sistema SCADA Spectrum de SIEMENS del CDEC-SIC. Especificaciones de conexión al SITR del CDEC-SIC 14 de 19 CDEC-SIC Dirección de Operación Mayo de 2007 ANEXO 4.- PROTOCOLOS IEC 870-5-104/101 Y DNP3.0 TCP-IP/SERIAL: PERFILES En el caso de una conexión vía RTU, el CDEC-SIC indicará al coordinado las direcciones lógicas dentro del protocolo asociadas a los puntos que serán transmitidos. En el caso de una conexión TCP/IP, el CDEC-SIC indicará al coordinado las direcciones lógicas dentro del protocolo asociadas a los puntos que serán transmitidos, así como direcciones IP o direcciones de puertas físicas, etc. Especificaciones de conexión al SITR del CDEC-SIC 15 de 19 CDEC-SIC Dirección de Operación Mayo de 2007 Perfil IEC 870-5-104/101 Perfil IEC-104-101.pdf Especificaciones de conexión al SITR del CDEC-SIC 16 de 19 IEC-60870-5-101 ______________________________________________________________________ 1.1 Communication profiles 1.1.1 Protocol IEC870-5-101 This chapter contains the protocol checklist according to IEC870-5-101 Interopetability. The protocol checklist for IEC..101 defines the protocol functions for the TCB interfaces concerning the RTUs directly connected via conventional telecontrol links. The checklist for IEC..-101 is included here also because the basic communication procedures (General Interrogation, Command Transmission etc.) are the same for both protocol stacks IEC..-101 and IEC..-104. IEC-60870-5-101 ______________________________________________________________________ „Companion standard for basic telecontrol tasks“ A1 - 1 Interoperability The companion standard defined above presents sets of parameters and alternatives from which subsets have to be selected to implement particular telecontrol systems. Certain parameter values, such as the number of octets in the COMMON ADDRESS of ASDUs represent mutually exclusive alternatives. This means that only one value of the defined parameters is admitted per system. Other parameters, such as the listed set of different process information in command and in monitor direction allow the specification of the complete set or subsets, as appropriate for given applications. This clause summarizes the parameters of the previous clauses to facilitate a suitable selection for a specific application. If a system is composed of equipment from different manufacturers it is necessary that all partners agree on the selected parameters. The selected parameters should be crossed in the white boxes. Note: In addition, the full specification of a system may require individual selection of certain parameters for certain parts of the system, such as the individual selection of scaling factors for individually addressable measured values. Note: Functions which are not (yet) implemented in Siemens Spectrum System do not have the check box " ". Further investigations are needed if they are required. Mandatory items are marked by " ". Parameters which are in addition or different to the TCS 101 are written in italic. A1 - 1.1 Network Configuration ⌧ Configuration Remark Multiple Point-to Point redundant communication links? (y / n / some) Multipoint-Partyline Ditto Multipoint-Star Ditto A1 - 1.2 Physical Layer Transmission Speed (common for both directions) ⌧ Circuit V.24 / V.28 (RS 232) Speed Circuit X.24/X.27 (RS485) / applicable only for TCI Remark Speed 100 bit/s ⌧ Remark 4 800 bit/s 200 bit/s ⌧ 300 bit/s ⌧ 19 200 bit/s 600 bit/s 38 400 bit/s 1 200 bit/s 56 000 bit/s 2 400 bit/s 64 000 bit/s 9 600 bit/s applicable only for TCI IEC-60870-5-101 ______________________________________________________________________ A1 - 1.3 Link Layer Frame format FT 1.2, single character1(=E5) and the fixed time out interval are used exclusively in this companion standard. Link transmission procedure Procedure ⌧ Remark Balanced Transmission Send / No reply in monitoring direction only for balanced transmission relevant Unbalanced Transmission Number of Data Class 1 requests__ Number of Data Class 2 requests__ ⌧ default: 2 default: 4 (only for unbalanced transmission relevant) max. length of the message 116 (number of octets) default: 255 Number of repeats_____ default: 2 Address field of the link Description Remark not present only for balanced transmission 1 Octet ⌧ 2 Octets structured ⌧ only relevant if 2 octets are used unstructured A1 - 1.4 Application Layer Transmission Mode for Application Data Mode 1 (least significant octet first), as defined in clause 4.10 of IEC 870-5-4, is used exclusively in this standard. Common Address of ASDU Description Remark 1 Octet ⌧ 2 Octets structured unstructured only relevant if 2 octets are used IEC-60870-5-101 ______________________________________________________________________ Information Object Address Description Remark 1 Octet 2 Octets ⌧ 3 Octets ⌧ structured Example for structured addressing scheme: 1st octet: Feeder Number (1 ... 255) 2nd octet: Info Group (1 ... 255) 3rd octet: Info No. (1 ... 255) unstructured Cause of Transmission 1 Octet 2 Octets 2nd octet is used as "Originator Address" Test bit Test bit is not evaluated in the Spectrum System Selection of Standard ASDUs Process Information in Monitor Direction Type Ident ⌧ ⌧ ⌧ ⌧ ASDU Description Remark <1> M_SP_NA_1 Single-point information <2> M_SP_TA_1 Single-point information with time tag <3> M_DP_NA_1 Double-point information <4> M_DP_TA_1 Double-point information with time tag <5> M_ST_NA_1 Step position information <6> M_ST_TA_1 Step position information with time tag <7> M_BO_NA_1 Bitstring of 32 bit <8> M_BO_TA_1 Bitstring of 32 bit with time tag <9> M_ME_NA_1 Measured value, normalized value recommended type <10> M_ME_TA_1 Measured value, normalized value with time tag time tag is evaluated by Spectrum only in case of limit violation <11> M_ME_NB_1 Measured value, scaled IEC-60870-5-101 ______________________________________________________________________ value <12> M_ME_TB_1 Measured value, scaled value with time tag <13> M_ME_NC_1 Measured value, short floating point value <14> M_ME_TC_1 Measured value, short floating point value with time tag <15> M_IT_NA_1 Integrated totals <16> M_IT_TA_1 Integrated totals with time tag <17> M_EP_TA_1 Event of protection equipment with time tag ( ) <18> M_EP_TB_1 Packed start events of protection equipment with time tag on request ( ) <19> M_EP_TC_1 Packed output circuit information of protection equipment with time tag on request <20> M_PS_NA_1 Packed single-point information with status change detection <21> M_ME_ND_1 Measured value, normalized value without quality descriptor ⌧ see Remark of TI <10> see Remark of TI <10> transmitted time tag is discardedby Spectrum <30> := Single-point information with time tag CP56Time2a M_SP_TB_1 <31> := Double-point information with time tag CP56Time2a M_DP_TB_1 <32> := Step position information with time tag CP56Time2a M_ST_TB_1 <33> := Bitstring of 32 bit with time tag CP56Time2a M_BO_TB_1 <34> := Measured value, normalized value with time tag CP56Time2a M_ME_TD_1 <35> := Measured value, scaled value with time tag CP56Time2a M_ME_TE_1 <36> := Measured value, short floating point value with time tag CP56Time2a M_ME_TF_1 <37> := Integrated totals with time tag CP56Time2a M_IT_TB_1 <38> := Event of protection equipment with time tag CP56Time2a M_EP_TD_1 <39> := Packed start events of protection equipment with time tag CP56Time2a M_EP_TE_1 <40> := Packed output circuit information of protection equipment with time tag CP56Time2a M_EP_TF_1 IEC-60870-5-101 ______________________________________________________________________ Cause of Transmission CoT Cause Remark <1> periodic, cyclic Only used for cyclic measured values without time tag. <2> background scan <3> spontaneous <5> requested <7> activation confirmation <9> deactivation confirmation <10> activation termination <11> return information caused by a remote command <12> return information caused by a local command <20> interrogated by general interrogation Quality Descriptors Evaluated by the SPECTRUM System QoI Description Remark <NT not topical applicable for all information <IV> invalid for measured values, integrated totals <OV> overflow for measured values, tap changer positionstreated as "invalid" <SB> substituted applicable for all information <BL> blocked applicable for all information Remark: Invalid time tags are passed-on from process interface to the Communicator without change. IEC-60870-5-101 ______________________________________________________________________ Process information in control direction Type Ident ASDU Description ⌧ <45> C_SC_NA_1 Single command ⌧ <46> C_DC_NA_1 Double command ⌧ ⌧ <47> C_RC_NA_1 Regulating step command <48> C_SE_NA_1 Set point command, normalized value <49> C_SE_NB_1 Set point command, scaled value <50> C_SE_NC_1 Set point command, short floating point value <51> C_BO_NA_1 Bitstring of 32 bits Remark System Information in Monitoring Direction ⌧ <70> M_EI_NA_1 End of initialization COI parameters are not evaluated System Information in Control Direction Type Ident ASDU Description Remark <100> C_IC_NA_1 Interrogation command <101> C_CI_NA_1 Counter interrogation command not supported not supported <102> C_RD_NA_1 Read command <103> C_CS_NA_1 Clock synchronization command <104> C_TS_NA_1 Test command not supported <105> C_RP_NA_1 Reset process command not supported IEC-60870-5-101 ______________________________________________________________________ Parameter in Control Direction Type Ident ASDU Description Remark ( ) <110> P_ME_NA_P q KPA=1 KPA=2 KPA=3/4 Parameter of measured value, normalized value - threshold - smoothing factor - low / high limit on request ( ) <111> P_ME_NB_1 KPA=1 KPA=2 KPA=3/4 Parameter of measured value, scaled value - threshold - smoothing factor - low / high limit ditto ( ) <112> P_ME_NC_1 Parameter of measured value, short floating point value - threshold - smoothing factor - low / high limit ditto Parameter activation - act / deact of cyclic transmission not supported KPA=1 KPA=2 KPA=3/4 <113> P_AC_NA_1 QPA=3 File Transfer in Monitoring Direction File Transfer in Control Direction File Transfer Type Ident ASDU Description <120> F_FR_NA_1 File ready <121> F_SR_AN_1 Section ready <122> F_SC_NA_1 Call directory, select file, call file, call selection <123> F_LS_NA_1 Last section <124> F_AF_NA_1 Ack file, ack section <125> F_SG_NA_1 Segment <126> F_DR_TA_1 Directory Remark not implemented Note: Source or destination of the file transfer is a directory of the process controlling DAS server. Preparation or evaluation of the file contents on any other Spectrum server is subject of extra effort. IEC-60870-5-101 ______________________________________________________________________ A1 - 1.5 Basic Application Functions General Interrogation Type Ident ASDU Description Remark <100> C_IC_NA_1 (QOI=20) global G I the following COT parameters are applied: in control direction: <6> activation (C_IC ACT)in monitoring direction:<7> activation confirmation (C_IC ACTCON) <10> activation termination (C_IC ACTTERM) <100> C_IC_NA_1 (QOI=21) group 1 not supported <100> C_IC_NA_1 (QOI=22) group 2 ditto etc. group 3 ditto group 4 ditto group 5 ditto group 6 ... 16 ditto ditto Addresses per group have to be defined Command Transmission Description Remark Direct command transmission Direct set-point command transmission Command termination not supported ⌧ Select and execute command (SCADA function in 3.x) ⌧ Select and execute set-point command (SCADA function in 3.x) C_SE ACTTERM used arbitrary Qualifier for Command Transmission ⌧ QOC Description Remark <0> no additional definition individual command output pulses are to be parameterized in the RTU <1> Short pulse duration (duration determined by a system parameter in the outstation) <2> Long pulse duration(duration determined by a system parameter in the outstation) <3> Persistent output not supported IEC-60870-5-101 ______________________________________________________________________ (others to be defined) IEC-60870-5-101 ______________________________________________________________________ Counter Interrogation Commands Type Ident ASDU Description Remark <101> C_CI_NA_1. ..(FRZ=0) no freeze or reset not supported ...(FRZ=1) counter freeze without reset ditto ...(FRZ=2) counter freeze with reset ditto ...(FRZ=3) counter reset ditto ...(RQT=0) no counter request ditto ...(RQT=1) request counter group 1 ditto ...(RQT=2) request counter group 2 ditto ...(RQT=3) request counter group 3 ditto ...(RQT=4) request counter group 4 ditto ...(RQT=5) general request counter ditto Note: all counter commands (freeze, reset) are to be carried out by the RTU. The transmission of the counter messages is initialized by the RTU spontaneously after each freezing. CDEC-SIC Dirección de Operación Mayo de 2007 Anexo para IEC870-5-104 (Conexión RTU) Anexo A_Perfil IEC104.pdf Especificaciones de conexión al SITR del CDEC-SIC 17 de 19 TIME-OUTs PARA IEC870-5-104 Definición de “Time-outs” Parámetro Valor por Defecto to 30 s t1 15 s t2 10 s t3 30 s Notas Valor Adoptado “Time-out” de establecimiento de conexión “Time-out” de APDU del tipo “send” o “test” “Time-out” para confirmaciones en caso de mensajes sin datos t2 < t1 “Time-out” para envío de tramas de tipo “S” en caso de periodos largos de inactividad t3 > t1 60 s 15 s 10 s 30 s Rango de valores para todos los “time-outs” es de: 1 a 255 s, con una precisión de 1 s. Número máximo de APDU tipo “I” y última confirmación Parámetro Valor por Defecto K 12 APDUs w 8 APDUs Notas Valor Adoptado Máxima diferencia entre números de secuencia para enviar una variable de estado. Último reconocimiento después de recibir “w” APDUs del tipo “I” 12 8 El rango de valores para “k”: 1 hasta 32767 (215 - 1) APDUs. Precisión de 1 APDU. El rango de valores para “w”: 1 hasta 32767 APDUs. Precisión de 1 APDU (Se recomienda que “w” no exceda de 2/3 de k) Número de puerto Parámetro puerto Valor por Defecto 2404 Notas En todos los casos RFC 2200 suite RFC 2200 es un estándar oficial de “Internet” que describe el estado de estandarización de los protocolos utilizados en “internet” como se dictamina por “the Internet architecture board” (IAB). Ofrece un amplio espectro de estándares utilizados en “internet”. La selección más adecuada de documentos de RFC2200 definidos en este estándar para el proyecto debe se elegida por el usuario de este estándar. X Ethernet 802.3 Otras selecciones de RFC2200 Lista de documentos válidos de RFC2200 1.- ______________________________ 2.- ______________________________ 3.- ______________________________ 4.- ______________________________ CAUSAS DE TRANSMISIÓN RTU PROTOCOLO IEC870-5-104 Los mensajes de la siguiente tabla corresponden a mensajes con información de proceso y viajan desde una unidad remota hacia el centro de control. Estos mensajes NO tienen confirmación a nivel de aplicación. Tipo Significado Nemotécnico <1> <3> Estado digital simple sin marca de tiempo Estado digital doble sin marca de tiempo M_SP_NA_1 M_DP_NA_1 <5> Posición de paso M_ST_NA_1 <11> Medida analógica, valor escalado M_ME_NB_1 <15> <30> <31> Totales integrados Estado digital simple con marca de tiempo extendida Estado digital doble con marca de tiempo extendida M_IT_NA_1 M_SP_TB_1 M_DP_TB_1 Causa de Transmisión <20> <20> <3> <20> <3> <20> <3> <3> <3> General Interrogation General Interrogation Spontaneous General Interrogation Spontaneous General Interrogation Spontaneous Spontaneous Spontaneous Los mensajes de la siguiente tabla corresponden a mensajes con información de proceso y viajan desde el centro de control hacia una unidad remota. Estos mensajes SI tienen confirmación a nivel de aplicación. Es decir, la unidad remota los refleja cambiando únicamente el primer byte del campo “causa de transmisión”. Tipo Significado Nemotécnico <45> Comando simple C_SC_NA_1 <46> Comando doble C_DC_NA_1 <47> Comando de posición de paso C_RC_NA_1 <49> Comando de consigna, valor escalado C_SE_NB_1 Causa de Transmisión <6> Activation <8> Deactivation <7> Activation Confirmation <9> Deactivation Confirmation <10> Activation Termination <6> Activation <8> Deactivation <7> Activation Confirmation <9> Deactivation Confirmation <10> Activation Termination <6> Activation <8> Deactivation <7> Activation Confirmation <9> Deactivation Confirmation <10> Activation Termination <6> Activation <8> Deactivation <7> Activation Confirmation <9> Deactivation Confirmation <10> Activation Termination Los mensajes de la siguiente tabla corresponden a mensajes con información de sistema y viajan desde el centro de control hacia la unidad remota. Estos mensajes SI tienen confirmación a nivel de aplicación. Es decir, la unidad remota los refleja cambiando únicamente el primer byte del campo “causa de transmisión” Tipo <100> Significado Comando de interrogación Nemotécnico C_IC_NA_1 Causa de Transmisión <6> Activation <8> Deactivation <7> Activation Confirmation <9> Deactivation Confirmation <10> Activation Termination CDEC-SIC Dirección de Operación Mayo de 2007 Perfil DNP 3.0 TCP-IP/Serial: Perfil DNP3.pdf Especificaciones de conexión al SITR del CDEC-SIC 18 de 19 6,1$876SHFWUXP ,QWHURSHUDELOLW\/LVW'13IRU/HYHO 7HOHFRQWURO,QWHUIDFH7&, ,QWHURSHUDELOLW\/LVW'13IRU/HYHO The companion standard defined presents sets of parameters and alternatives from which subsets have to be selected to implement particular telecontrol systems. Certain parameter values, such as the number of octets in the COMMON ADDRESS of ASDUs represent mutually exclusive alternatives. This means that only one value of the defined parameters is admitted per system. Other parameters, such as the listed set of different process information in command and in monitor direction allow the specification of the complete set or subsets, as appropriate for given applications. This clause summarizes the parameters of the previous clauses to facilitate a suitable selection for a specific application. If a system is composed of equipment stemming from different manufacturers it is necessary that all partners agree on the selected parameters. Copyright Siemens AG 2000. All Rights Reserved. DNP restrictions that will be applied are as follows: a. Redundancy: Master operates in a shared-redundancy mode. If line is assigned to the primary channel, then no check is made of the secondary (back-up) channel For RTUs connected by a single transmission line, this redundancy approach is like moving the line from one front-end processor to another. At this time, for RTUs connected by independent communications lines (dual ported RTUs), the back-up line is not used until the primary front-end processor fails over to the secondary. b. All RTUs will be configured independently by an off-line process. Siemens does not write configuration data (i.e. association of hardware to software) to RTUs at system start-up time. However, assignment of certain categories of event data to data classes (i.e. digital events to Class 1, analog to Class 2, etc.) *is* supported. c. European projects have used a scheme called “Double Channels”. This method of redundancy is not supported. d. Broadcast commands are not supported. e. All measurement values are mapped to a 16 bit value with a range from 215-1 to -215. f. The TCI supports no nodes with the DNP 3.00 implementation. The selected parameters should be crossed in the white boxes. In addition, the full specification of a system may require individual selection of certain parameters for certain parts of the system, such as the individual selection of scaling factors for individually addressed measured values. 1RWH 7KHFKHFNER[HV\RXZLOOILQGEHORZKDYHWKHIROORZLQJPHDQLQJ q LPSOHPHQWHGE\6LHPHQV7HOHFRQWURO,QWHUIDFH n/i QRWLPSOHPHQWHGE\6LHPHQV7HOHFRQWURO,QWHUIDFH x VXEVHWVHOHFWHGIRUWKLVSURMHFWHPSW\FKHFNER[WREHUHSODFHGE\WKLVV\PERO n PDQGDWRU\ F-DA02-E-1.3.0.0 Version 1.3.0.0, 09/00 -1 6,1$876SHFWUXP ,QWHURSHUDELOLW\/LVW'13IRU/HYHO 7HOHFRQWURO,QWHUIDFH7&, 1HWZRUN&RQILJXUDWLRQ &RQILJXUDWLRQ Point-to Point q Multiple Point-to Point q Multipoint-Partyline q Multipoint-Star redundant communication links (yes | no) redundant communication links (yes | no) redundant communication links (yes | no) Copyright Siemens AG 2000. All Rights Reserved. q 5HPDUN F-DA02-E-1.3.0.0 Version 1.3.0.0, 09/00 -2 6,1$876SHFWUXP ,QWHURSHUDELOLW\/LVW'13IRU/HYHO 7HOHFRQWURO,QWHUIDFH7&, 3K\VLFDO/D\HU 7UDQVPLVVLRQ6SHHGFRPPRQIRUERWKGLUHFWLRQV Unbalanced Interchange Circuit V.24 / V.28 Standard Copyright Siemens AG 2000. All Rights Reserved. 6SHHG 5HPDUN 6SHHG 5HPDUN n/i 100 bit/s q 4 800 bit/s n/i 200 bit/s q 9 600 bit/s n/i 300 bit/s q 19 200 bit/s n/i 600 bit/s n/i 38 400 bit/s TCB Version 2 (X.27) required q 1 200 bit/s n/i 56 000 bit/s ditto q 2 400 bit/s n/i 64 000 bit/s ditto F-DA02-E-1.3.0.0 Version 1.3.0.0, 09/00 -3 6,1$876SHFWUXP ,QWHURSHUDELOLW\/LVW'13IRU/HYHO 7HOHFRQWURO,QWHUIDFH7&, 'DWD/LQN/D\HU The data link layer uses a standard variable length frame format as defined in the IEC 870-5-1 Transmission Frame Formats document. The FT3 frame format class is well suited for data transmission between stations that require medium information transfer rates and low residual error probability. Copyright Siemens AG 2000. All Rights Reserved. 3URFHGXUH 5HPDUN q Maximum Data Link Frame Size (octets): Transmitted: 255 + Header (292) Received: (must be 292) q Maximum Data Link Re-tries: Configurable, range 0 to 255 n/i Unsolicited Responses 3.1 Unsolicited Responses are not supported Function code Field Values of Control octet Sent from the primary station (PRM=1) )XQFWLRQ )UDPH7\SH &RGH 6HUYLFH)XQFWLRQ )&9 %LW q 0 SEND - CONFIRM expected Reset of remote link 0 q 1 SEND - CONFIRM expected Reset of user link 0 q 2 SEND - CONFIRM expected Test function for link 1 q 3 SEND - CONFIRM expected User data 1 q 4 SEND - NO REPLAY expected Unconfirmed user data 0 n/i 5 Not used - n/i 6 Not used - n/i 7 Not used - n/i 8 Not used - q 9 Request link status 0 n/i 10 Not used - n/i 11 Not used - n/i 12 Not used - n/i 13 Not used - n/i 14 Not used - n/i 15 Not used - REQUEST - RESOPNSE expected F-DA02-E-1.3.0.0 Version 1.3.0.0, 09/00 -4 6,1$876SHFWUXP ,QWHURSHUDELOLW\/LVW'13IRU/HYHO 7HOHFRQWURO,QWHUIDFH7&, 3.2 Function code Field Values of Control octet Sent from the secondary station (PRM=0) Copyright Siemens AG 2000. All Rights Reserved. )XQFWLRQ )UDPH7\SH &RGH 6HUYLFH)XQFWLRQ q 0 CONFIRM Ack - positive acknowledgment q 1 CONFIRM NACK - MEssage not accepted, Link busy n/i 2 Not used n/i 3 Not used n/i 4 Not used n/i 5 Not used n/i 6 Not used n/i 7 Not used n/i 8 Not used n/i 9 Not used n/i 10 Not used q 11 n/i 12 Not used n/i 13 Not used q 14 Link service not functioning q 15 Link service not used or implemented RESPOND F-DA02-E-1.3.0.0 Status of Link (DCF = 0 or DFC = 1) Version 1.3.0.0, 09/00 -5 6,1$876SHFWUXP ,QWHURSHUDELOLW\/LVW'13IRU/HYHO 7HOHFRQWURO,QWHUIDFH7&, 4.1 q 7UDQVSRUW/D\HU Fragmentation for transport frames in receive direction 3URFHGXUH 5HPDUN Fragmented transport frames Maximum frame size: 1300 octets Fragmented transport frames will be supported only in receive direction. Maximum transport fragment size: Copyright Siemens AG 2000. All Rights Reserved. q 4.2 n/i Maximum data link data count Data link header data count Transport header Application Header +255 -5 -1 =249 octets octets octet octets Fragmentation for transport frames in transmit direction 3URFHGXUH 5HPDUN Fragmented transport frames Fragmented transport frames will not be supported in transmit direction. F-DA02-E-1.3.0.0 Version 1.3.0.0, 09/00 -6 6,1$876SHFWUXP ,QWHURSHUDELOLW\/LVW'13IRU/HYHO 7HOHFRQWURO,QWHUIDFH7&, 5.1 q Copyright Siemens AG 2000. All Rights Reserved. 5.2 n/i 5.3 $SSOLFDWLRQ/D\HU Fragmentation for application frames in receive direction 3URFHGXUH 5HPDUN Fragmented application frames Maximum frame size: 1300 octets Fragmented application frames will be supported only in receive direction. Fragmentation for application frames in transmit direction 3URFHGXUH 5HPDUN Fragmented application frames Fragmented application frames will not be supported in transmit direction. FIR and FIN bits are always set to ’1’. Function codes &RGH )XQFWLRQ 7UDQVIHU)XQFWLRQ&RGHV q 0 Confirm q 1 Read q 2 Write &RQWURO)XQFWLRQ&RGHV q 3 Select q 4 Operate q 5 Direct Operate n/i 6 Direct Operate - No Acknowledgment )UHH]H)XQFWLRQ&RGHV q 7 Immediate Freeze q 8 Immediate Freeze - No Acknowledgment 7UDQVIHU)XQFWLRQ&RGHV n/i 9 Freeze and Clear n/i 10 Freeze and Clear - No Acknowledgment n/i 11 Freeze and Time F-DA02-E-1.3.0.0 Version 1.3.0.0, 09/00 -7 6,1$876SHFWUXP ,QWHURSHUDELOLW\/LVW'13IRU/HYHO 7HOHFRQWURO,QWHUIDFH7&, &RGH n/i 12 )XQFWLRQ Freeze and Time - No Acknowledgment $SSOLFDWLRQ)XQFWLRQ&RGHV n/i 13 Cold Restart n/i 14 Warm Restart n/i 15 Initialize Data to Default n/i 16 Initialize Application n/i 17 Start Application n/i 18 Stop Application Copyright Siemens AG 2000. All Rights Reserved. &RQILJXUDWLRQ)XQFWLRQ&RGHV n/i 19 Save Configuration n/i 20 Enable Unsolicited Messages n/i 21 Disable Unsolicited Messages n/i 22 Assign Class 7LPH6\QFKURQL]DWLRQ)XQFWLRQ&RGHV q 23 Delay Measurement 5HVHUYH n/i 24 - 120 Reserved for future use n/i 121 -128 Reserved for testing only 5HVSRQVH)XQFWLRQ&RGHV q 0 q 129 Response n/i 130 Unsolicited Messages F-DA02-E-1.3.0.0 Confirm Version 1.3.0.0, 09/00 -8 6,1$876SHFWUXP ,QWHURSHUDELOLW\/LVW'13IRU/HYHO 7HOHFRQWURO,QWHUIDFH7&, 'DWD2EMHFWVDQG)XQFWLRQV Copyright Siemens AG 2000. All Rights Reserved. 2EMHFW*URXS9DULDWLRQ 5HTXHVW)XQFWLRQ 4XDOLILHU D 5HVSRQVH )XQFWLRQ 4XDOLILHUD q Single-Bit Binary Input (1,1) Read 01, 06 Response X n/i Single-Bit Binary Input (1,1) Assign Class 01, 06 Response X q Binary Input with Status (1,2) Read 01, 06 Response X q Binary Input Change Without Time Read (2,1) 01, 06 Response X n/i Binary Input Change Without Time Assign Class (2,1) 01, 06 Response X q Binary Input Change With Time (2,2) Read 01, 06 Response X n/i Binary Input Change With Time (2,2) Assign Class 01, 06 Response X q Binary Input Change With Relative Read Time (2,3) 01, 06 Response X n/i Binary Input Change With Relative Assign Class Time (2,3) 01, 06 Response X q Binary Output Status 10,2) Read 01, 06 Response X n/i Binary Output Status (10,2) Assign Class 01, 06 Response X q Control Relay Output Block (12,1) Select, Operate, Direct Operate 28 Response Echoes Request n/i Pattern Control Block (12,2) n/i Pattern Mask (12,3) q 32-Bit Binary Counter (20,1) Read 01, 06 Response X q 16-Bit Binary Counter (20,2) Read 01, 06 Response X q 32-Bit Delta Counter (20,3) Read 01, 06 Response X q 16-Bit Delta Counter (20,4) Read 01, 06 Response X q 32-Bit Binary Counter Without Flag (20,5) Read 01, 06 Response X q 16-Bit Binary Counter Without Flag (20,6) Read 01, 06 Response X q 32-Bit Delta Counter Without Flag Read (20,7) 01, 06 Response X q 16-Bit Delta Counter Without Flag Read (20,8) 01, 06 Response X q 32-Bit Frozen Counter (21,1) Read 01, 06 Response X q 16-Bit Frozen Counter (21,2) Read 01, 06 Response X F-DA02-E-1.3.0.0 Version 1.3.0.0, 09/00 -9 6,1$876SHFWUXP ,QWHURSHUDELOLW\/LVW'13IRU/HYHO 7HOHFRQWURO,QWHUIDFH7&, Copyright Siemens AG 2000. All Rights Reserved. 2EMHFW*URXS9DULDWLRQ 5HTXHVW)XQFWLRQ 4XDOLILHUD 5HVSRQVH )XQFWLRQ 4XDOLILHUD q 32-Bit Frozen Delta Counter (21,3) Read 01, 06 Response X q 16-Bit Frozen Delta Counter (21,4) Read 01, 06 Response X q 32-Bit Frozen Counter Without Flag (21,9) Read 01, 06 Response X q 16-Bit Frozen Counter Without Flag (21,10) Read 01, 06 Response X q 32-Bit Frozen Delta Counter WithRead out Flag (21,11) 01, 06 Response X q 16-Bit Frozen Delta Counter WithRead out Flag (21,12) 01, 06 Response X q 32-Bit Counter Change Event Without Time (22,1) Read 01, 06 Response X q 16-Bit Counter Change Event Without Time (22,2) Read 01, 06 Response X q 32-Bit Delta Counter Change Event Without Time (22,3) Read 01, 06 Response X q 16-Bit Delta Counter Change Event Without Time (22,4) Read 01, 06 Response X q 32-Bit Counter Change Event With Time (22,5) Read 01, 06 Response X q 16-Bit Counter Change Event With Time (22,6) Read 01, 06 Response X q 32-Bit Delta Counter Change Event With Time (22,7) Read 01, 06 Response X q 16-Bit Delta Counter Change Event With Time (22,8) Read 01, 06 Response X q 32-Bit Frozen Counter Event WithRead out Time (23,1) 01, 06 Response X q 16-Bit Frozen Counter Event WithRead out Time (23,2) 01, 06 Response X q 32-Bit Frozen Delta Counter Event Read Without Time (23,3) 01, 06 Response X q 16-Bit Frozen Delta Counter Event Read Without Time (23,4) 01, 06 Response X q 32-Bit Frozen Counter Event With Read Time (23,5) 01, 06 Response X F-DA02-E-1.3.0.0 Version 1.3.0.0, 09/00 - 10 6,1$876SHFWUXP ,QWHURSHUDELOLW\/LVW'13IRU/HYHO 7HOHFRQWURO,QWHUIDFH7&, Copyright Siemens AG 2000. All Rights Reserved. 2EMHFW*URXS9DULDWLRQ 4XDOLILHUD 5HTXHVW)XQFWLRQ 5HVSRQVH )XQFWLRQ 4XDOLILHUD q 16-Bit Frozen Counter Change With Time (23,6) Read 01, 06 Response X q 32-Bit Frozen Delta Counter Event Read With Time (23,7) 01, 06 Response X q 16-Bit Frozen Delta Counter Event Read With Time (23,8) 01, 06 Response X q 32-Bit Analog Input (30,1) Read 01, 06 Response X q 16-Bit Analog Input (30,2) Read 01, 06 Response X q 32-Bit Analog Input Without Flag Read (30,3) 01, 06 Response X q 16-Bit Analog Input Without Flag Read (30,4) 01, 06 Response X q 32-bit Analog Change Event WithRead, Assign Class 06 out Time (32,1) Response X q 16-bit Analog Change Event WithRead, Assign Class 06 out Time (32,2) Response X q 32-bit Analog Change Event With Read, Assign Class 06 Time (32,3) Response X q 16-bit Analog Change Event With Read, Assign Class 06 Time (32,4) Response X q 32-Bit Analog Output (41,1) Select, Operate, Direct Operate 28 Response Echoes Response q 16-Bit Analog Output (41,2) Select, Operate, Direct Operate 28 Response Echoes Response q Time and Data (50,1) Write 07 Response X n/i Time and Data with Interval (50,2) q Time and Data CTO (51,1) Read X Response X q Unsynchronized Time and Data CTO (51,2) Read X Response X n/i Time Delay Coarse Information (52,1) q Time Delay Fine (52,2) Delay Measurement 07 Response 07 q Class Zero Data (60,1) Read Response q Class One Data (60,2) Read, Assign Class 06, 08 Response q Class Two Data (60,3) Read, Assign Class 06, 08 Response q Class Three Data (60,4) Read, Assign Class 06, 08 Response n/i File Identifier (70,1) F-DA02-E-1.3.0.0 06 Version 1.3.0.0, 09/00 - 11 6,1$876SHFWUXP ,QWHURSHUDELOLW\/LVW'13IRU/HYHO 7HOHFRQWURO,QWHUIDFH7&, Copyright Siemens AG 2000. All Rights Reserved. 2EMHFW*URXS9DULDWLRQ q Internal Indications (80,1) n/i Storage Object (81,1) n/i Device Profile (82,1) n/i Private Registration Object (83,1) n/i Private Registration Object Descriptor (83,2) n/i Application Identifier (90,1) n/i Short Floating Point (100,1) n/i Long Floating Point (100,2) n/i Extended Floating Point (100,3) n/i Small Packed Binary-Coded Decimal (101,1) n/i Medium Packed Binary-Coded Decimal (101,2) n/i Large Packed Binary-Coded Decimal (101,3) a 5HTXHVW)XQFWLRQ Write 4XDOLILHUD 00 5HVSRQVH )XQFWLRQ Response 4XDOLILHUD 00 ¶;¶LQGLFDWHVWKDWWKHTXDOLILHUFRGHVLQ+H[IRUWKHPDUNHGREMHFWVDUHVXSSRUWHGIRUDOOW\SHV RIUHVSRQVHGDWD F-DA02-E-1.3.0.0 Version 1.3.0.0, 09/00 - 12 CDEC-SIC Dirección de Operación ANEXO 5 Mayo de 2007 PROTOCOLOS IEC 870-5-101 Y DNP3.0 SERIAL: DISPOSITIVO DERIVADOR ModemShare Devices 56606668[1] Especificaciones de conexión al SITR del CDEC-SIC 19 de 19 Siemens Power T&D, Inc. Energy Management & Information Systems Doc. 56606668 Rev. 01 Page 1 of 7 Code Ident. 71682 Specification Control Document Modem Sharing Device, Active, SMSD3 With Case for Modem Rack Mounting, Screwlock Arrangement #2 Note: See Spec. 56605890 for SMSD with Screwlock Arrangement #1- Panel Mounting 56606660 for SMSD2 with Screwlock Arrangement #2- Modem Mounting M. Brown _________________ Originator M. Brown ____________________ Engineer _________________ Checked ____________________ Approved Revision Record Rev ECO 01 Description Initial Draft Appd. Date 08/22/05 _______________________________________________________________________ File (Word): 56606668.doc Siemens Power T&D, Inc. Energy Management & Information Systems Doc. 56606668 Rev. 01 Page 2 of 7 Code Ident. 71682 Scope 1.1 This specification defines the detail requirements for a Modem Sharing Device, based on RS232 ports, that incorporates active electronics and that is port-powered. 1.2 First Used On: OPPD project; also used as a general solution for RS232 line sharing by redundant CFE servers. 1.0 Requirements 2.1 Product Functional Description The device is a custom Modem Data Splitter for Siemens (designated SMSD3 by B&B Electronics), otherwise also known as an active Modem Sharing Device (designated MSD by legacy at Siemens). The device supports two slave ports and one master port for RS232 signals. Each slave port supports three input signals: TD, RTS, and DTR. Internal circuitry for these three input signals on the slave ports provides active RS232 chips in the circuit. The RS232 receiver chips tie into an AND gate and then out to an RS232 driver on the master port. In this way, it is guaranteed that when one slave port shuts down, it does not affect the other slave port’s data communications. The MSD is port-powered. (The supplier must design the device with the goal of minimizing internal power consumption so that the viability of port-powering is maximized.) Dual RJ11-4 pin female connectors, connected in parallel, are also included for optional 12vdc for applications in which port powering does not work (as specified by supplier). All of the signal lines coming in from the master port get passed directly to both slave ports. The MSD features one male DB25 pin connector on the master port. The two slave ports feature RJ45-10 pin female connectors. The MSD is packaged in an enclosure for one DB25 pin connector and two RJ45 connectors. Overall dimensions of the enclosure will be 3.95"L x 2.3"H x 0.7"W. The unit defined in this document differs from two earlier versions (B&B Electronics SMSD and SMSD2). SMSD3 differs from SMSD with screwlock arrangement and case width. SMSD3 differs from SMSD2 with a case width of 0.7 inch as shown in diagram 2. The original version device with screwlock arrangement #1 is detailed in Spec. 56605890. The second version with screwlock arrangement #2 is detailed in Spec. 56606660. All three devices (SMSD, SMSD2 & SMSD3) are electrically equivalent. In general, SMSD3 can replace SMSD2 for most or all applications. File (Word): 56606668.doc Siemens Power T&D, Inc. Energy Management & Information Systems Doc. 56606668 Rev. 01 Page 3 of 7 Code Ident. 71682 2.2 Technical Information Required of Supplier • Circuit Schematic. • Mechanical Dimensions Drawing, including all connector locations. • Specification of all conditions for applications that will require external power (e.g. perhaps minimum voltage levels on hardware handshaking signals). 2.3 Data Rate: Supports up to 115.2K bps. 2.4 Isolation Type: Non-Isolated 2.5 Surge Suppression Type: None 2.6 Enclosure Dimensions and Material The device is packaged in an enclosure that provides one DB25 connector on one end, and two RJ45-10 pin connectors on the other end. In typical usage, the device is mounted to a modem DB25 connector using standard jackscrew hardware for the DB25 connector. Overall dimensions of the enclosure will be 3.95" x 2.3" x 0.7". 2.7 Connectors and Connector Hardware Description: One male DB25 pin connector with standard holes using 2 male screwlocks and two female RJ45-10 pin connectors. In addition, two RJ11-4 pin jacks for external power; see description below under “Power Supply.” 2.8 Power Supply Port powered and optional external 12vdc powered. The optional external 12vdc power, if used, is connected at an RJ11-4 pin jack. A second RJ114 pin jack is internally connected in parallel with the first RJ11 jack, and this provides a means to connect external power in a daisy-chain manner between multiple devices. At each RJ11 jack, 2 adjacent pins on one side of the connector are used for positive polarity, and the 2 adjacent pins on the other side of the connector are used for negative polarity. File (Word): 56606668.doc Siemens Power T&D, Inc. Energy Management & Information Systems Doc. 56606668 Rev. 01 Page 4 of 7 Code Ident. 71682 2.9 Connector Pin Assignments See diagram. 2.10 Labeling Permanently identify the device with the following information: • Siemens part number and revision (from this Document) • Vendor name, code or logo • Vendor part number or model number • Date code of Manufacture Labeling method and format must be approved by the Siemens design control organization via first article inspection. Any later changes by the supplier to this method must also be approved prior to implementation. 2.11 Testing The manufacturer must individually test each device. Evidence of successful testing must be provided either individually or by lot. Individually stamping the devices, or certificate of testing for a date code lot, are examples of acceptable test evidence. 2.0 Vendor See Authorized Vendor List (AVL) for approved vendor and vendor part number. Do not rely on attached vendor data (if present) or other vendor references contained in this document. File (Word): 56606668.doc Siemens Power T&D, Inc. Energy Management & Information Systems Doc. 56606668 Rev. 01 Page 5 of 7 Code Ident. 71682 ______________________________________________________________________ 3.0 Tables & Diagrams TABLE 1: Connector Pin Assignments Port Name Connector Type Port A Port A Port A Port A Port A Port A Port A Port A Port A Port A RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female Port Name Connector Type Port B Port B Port B Port B Port B Port B Port B Port B Port B Port B RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female RJ45-10 pin-Female Connector Designation J1- 1 J1- 2 J1- 3 J1- 4 J1- 5 J1- 6 J1- 7 J1- 8 J1- 9 J1-10 Connector Designation J2- 1 J2- 2 J2- 3 J2- 4 J2- 5 J2- 6 J2- 7 J2- 8 J2- 9 J2-10 Table 1: continued on following sheet. File (Word): 56606668.doc RS232 Signal Name Ring DSR RTS-A Shield TXD-A RXD Signal Gnd CTS DTR-A CD RS232 Signal Name Ring DSR RTS-B Shield TXD-B RXD Signal Gnd CTS DTR-B CD Siemens Power T&D, Inc. Energy Management & Information Systems Doc. 56606668 Rev. 01 Page 6 of 7 Code Ident. 71682 Table 1: Continued Port Name Modem Modem Modem Modem Modem Modem Modem Modem Modem Modem Connector Type DB25-Male DB25-Male DB25-Male DB25-Male DB25-Male DB25-Male DB25-Male DB25-Male DB25-Male DB25-Male Connector Designation J3- 1 J3- 2 J3- 3 J3- 4 J3- 5 J3- 6 J3- 7 J3- 8 J3-20 J3-22 Port Name Connector Type Ext Power 1 Ext Power 1 Ext Power 1 Ext Power 1 RJ11-4 pin-Female RJ11-4 pin-Female RJ11-4 pin-Female RJ11-4 pin-Female J4- 1 J4- 2 J4- 3 J4- 4 12 VDC Positive 12 VDC Positive 12 VDC Negative 12 VDC Negative Ext Power 2 Ext Power 2 Ext Power 2 Ext Power 2 RJ11-4 pin-Female RJ11-4 pin-Female RJ11-4 pin-Female RJ11-4 pin-Female J5- 1 J5- 2 J5- 3 J5- 4 12 VDC Positive 12 VDC Positive 12 VDC Negative 12 VDC Negative File (Word): 56606668.doc Connector Designation RS232 Signal Name Shield TXD RXD RTS CTS DSR Signal Gnd CD DTR Ring Power Signal Name Siemens Power T&D, Inc. Energy Management & Information Systems Doc. 56606668 Rev. 01 Page 7 of 7 Code Ident. 71682 ____________________________________________________________________ DIAGRAM 1: Mating RJ45 & RJ11 Pin Orientation Mating RJ45 10-pin Plug Pin 1 Pin 1 Pin 10 Pin 4 Mating RJ11 4-pin Plug Viewed From Contact Side Viewed From Contact Side DIAGRAM 2: Connector Locations & Screwlock Arrangement - Modem Rack Mounting 3.95 inch 0.7 in 0.165 inch (Typical) Modem Port Port A RJ45-10 pin Female J1 Male screwlocks DB25 Male Port B RJ45-10 pin Female J2 J3 Pin 1 1.3 inch Approx. Side View File (Word): 56606668.doc J4 Power 1 RJ11-4 pin Female J5 Power 2 RJ11-4 pin Female End View