882.93010.00 CV1-315.1 AEC SRC AV5-10
Transcription
882.93010.00 CV1-315.1 AEC SRC AV5-10
AEC Whitlock SRC AV5, AV10 Hopper Loaders Reference Manual (PN: A0536580) for Complete Operation and Installation Instructions (Available online at www.aecinternet.com) Safety Concerns Quickstart Installation Checklist (Refer to main manual for complete installation instructions). Inputs 1. Convey—Signal from convey system to sequence valve. The presence of this signal initiates the filter cleaning and convey sequence. 2-6. Reserved Outputs 1. 2. 3. 4. Atmospheric valve A Atmospheric valve B Slide gate Reserved Reference electrical schematic 882.00682.00 (115 VAC); 882.00682.01 (24 VDC); or 882.00682.00 (Dist I/O). Control power switch must be on for unit to operate. Unit Operation (Refer to main manual for complete operating instructions). Upon reception of the convey signal at input 1, the filter cleaning sequence begins: 1. Atmospheric valves A & B alternate for the specified time and number of cycles, after which both are energized for the remainder of the convey cycle (i.e. until loss of convey signal at input 1). 2. When convey stops, the flapper (or slide gate) will open for material to be discharged from the hopper (or the specified amount time) or until a new convey signal is received, whichever comes first. 3. For systems where the slide gate is controlled by the blender system, a relay is provided for the purpose of interrupting the demand signal while the slide gate is open. Procedure for changing parameters: 1. Use the left and/or right arrow keys to navigate to the correct screen. Press the OK key; one of the numeric values on the screen will begin blinking. 2. Use the up/down arrow keys to select the value you wish to change. Use the + (plus) key to increase values; use the – (minus) key to decrease values. The longer the keys are held, the more the values change. 3. Press the OK key to accept the new value, or press the ESC key at any time to cancel the change. The change will not take effect until the OK key is pressed (you will see Writing on the display momentarily). All numeric values may be changed. AEC, Inc. 1100 Woodfield Road • Suite 588 • Schaumburg, IL 60173 USA Tel. 847.273.7700 • Fax 847.273.7804 Part No: 882.93010.00 Bulletin No: CV1-315.1 AEC Whitlock SRC AV5, AV10 Hopper Loaders Reference Manual (PN: A0536580) for Complete Operation and Installation Instructions (Available online at www.aecinternet.com) Step-by-Step: Main Screen. Set parameters for the control, as follows: A TIME B TIME CYCLES GATE TIME #.# #.# ### ### Time (seconds) atmospheric valve A is on during cleaning cycle. Time (seconds) atmospheric valve B is on during cleaning cycle. Number of cleaning cycles. Time to keep slide gate open after convey. Use the left & right arrow keys to switch from the main screen to the I/O screen and back. Adjusting Cycle Times, # of Cycles, and Gate Time: 1. From the Main Screen, press “OK”. This should cause the value of “A TIME” to flash. 2. Press + or – to change the time (increases or decreases by 0.1 second increments). 3. Press “OK” to save the update (Screen will display “WRITING during the update). 4. Press ↑ or ↓ to switch to another parameter. 5. Press + or – to change the value. 6. Press “OK” to save the update (Screen will display “WRITING during the update). Adjusting the amount of “Loads Before Clean”: 1. From the Main Screen, press the → arrow once, switching to the screen with “LOADS BEFORE CLEAN”. The default value is shown as “1”. 2. Press the “OK” button. This causes the value to flash. 3. Press + or – to change the value. 4. Press “OK” to save the update (Screen will display “WRITING during the update). AEC, Inc. 1100 Woodfield Road • Suite 588 • Schaumburg, IL 60173 USA Tel. 847.273.7700 • Fax 847.273.7804 Part No: 882.93010.00 Bulletin No: CV1-315.1 AEC Whitlock SRC AV5, AV10 Hopper Loaders Reference Manual (PN: A0536580) for Complete Operation and Installation Instructions (Available online at www.aecinternet.com) Parts Location (See next page for Parts List) SRC16/AV-5 AEC, Inc. 1100 Woodfield Road • Suite 588 • Schaumburg, IL 60173 USA Tel. 847.273.7700 • Fax 847.273.7804 SRC16/AV-10 Part No: 882.93010.00 Bulletin No: CV1-315.1 AEC Whitlock SRC AV5, AV10 Hopper Loaders Reference Manual (PN: A0536580) for Complete Operation and Installation Instructions (Available online at www.aecinternet.com) Spare Parts List (See previous page for Parts Location) AV-5 Item # 7 14 15 15 18 AV-10 Item # 7 14 15 15 17 Part Number Description Qty. A0556813 161.00245.00 732.00224.00 732.00225.00 A0555773 CYL, Air, 1.06BORE, 2”ST FLTR, BAG,SNAP, 4.625ODX12.5LG VLV,SOL,DUAL3WAY,1/4,115VAC VLV,SOL,DUAL 3WAY, ¼, 24VDC PLGR,3.25OD,URE,WHT,5/16-24,CS 2 4 1 1 2 Part Number Description Qty. A0556813 161.01770.00 732.00224.00 732.00225.00 A0555773 CYL,AIR,1.06BORE,2’ST FLTR,BAG,SNAP,4.625ODX24.5LG VLV,SOL,SUAL3WAY,1/4,115VAC VLV,SOL,DUAL3WAY,1/4,24VDC PLGR,3.25OD,URE,WHT,5/16-24,CS 2 4 1 1 2 *Note: Refer to the main manual for a complete Spare Parts List. AEC, Inc. 1100 Woodfield Road • Suite 588 • Schaumburg, IL 60173 USA Tel. 847.273.7700 • Fax 847.273.7804 Part No: 882.93010.00 Bulletin No: CV1-315.1