installation instructions for wall tub sets, two handle shower sets and

Transcription

installation instructions for wall tub sets, two handle shower sets and
P 99061
INSTALLATION INSTRUCTIONS FOR
WALL TUB SETS, TWO HANDLE SHOWER SETS
AND WALL LAVATORY SET
VALVES NUMBERED: 8090536RC & 9090536RC
2222 Camden Court, Oak Brook, IL 60523
Telephone: 800-PHYLRICH (749-5742) Fax: 866-800-9774
www.phylrich.com
P99061
Step 1
Step 3
Connect hot and cold corner valves using 1/2" copper
adaptors(A), copper lines (B) and copper tee (C). Note:
DO NOT APPLY HEAT DIRECTLY TO VALVE BODIES.
Center-to-center dimension to be specified by customer.
Connect 12" adaptors and copper supply lines to 1/2”
unions (part #7).
Secure the assembled valve once the proper location has
been determined. Connect the copper supply lines to the
hot and cold supplies.
Forshower
showerinstallation
head installation
go to
For
go to step
4. step 4.
For
wall
lavatory
and
wall
tub
spout
installation go to
For tub installation go to step 5.
For
stepwall
5. lavatory installation go to step 6.
Step 4 Shower Installation
Step2
Please refer to rough-in specifications P99061A to deterPlease refer to rough-in specifications P99005A to determine
“A”"A"
and
“B” dimensions
and
proper
locations
minethe
the
dimension
and the
proper
location
for for
the
the
valves.
The
“A”
dimension
is
from
the
tip
of
the
valve. The "A" dimension is from the tip of the stemstem
to the
tofinished
the finished
The “B”
is between
from the the
tip of
wall. wall.
Installation
of adimension
crossbeam
wall
studs
at thisvalve
location
is recommended.
the
threaded
shank
to the finished wall. Installation
of a crossbeam between the wall studs at this location is
recommended.
Page 1
Determine the proper locations for the showerhead. Install
a crossbeam and secure a 1/2" brass 90° elbow. Connect
elbow 3 to tee using copper lines and '/2" male adaptor.
Check all connections for leaks and flush all lines. Wall is
now ready to be closed. Proceed to step 4.1.
P99061
Step 4.1
Step 5.1
Once finished wall is installed, attach showerhead to the
long end of the 8" shower arm and slide fiange onto the
short end. attach shower arm to brass elbow. Check
connections for leaks Slide fiange against wall.
Proceed to step 6
Once finished wall is installed, cut the spout tube so that it
extends ¼” from the finished wall. Be sure to remove any
burrs around the cut surface. All burrs must be removed to
prevent damage to spout o-rings. Take note that spout
tube may need to be removed from wall in order to be cut.
Step 5 Spout Installation
Step 5.2 Wall Lavatory Installation
B
D
E
Determine the proper locations for the spout. (Note: the
outlet of the spout must be a minimum of 2” above the
floodplain of the tub.) Install a crossbeam and secure a
90° elbow. Connect elbow to tee using copper lines
and ½” male adaptor. Connect adaptor nut (D) and
spout tube (E) to elbow. Check all connections for
leaks and flush lines. Wall is now ready to be closed.
Proceed to step 5.1.
Page 2
Thread the spout mount base (F) onto the spout tube (E)
and secure in place by tightening setscrews (G). Be careful to mount the spout mount base (F) as close to the wall
as possible while maintaining horizontal alignment.
Use the alignment screws (H) as reference and align
them parallel to the floor.
P99061
Step 5.3
Step 6
Align alignment grooves on the spout with the alignment
screws (H). Insert the spout adaptor (I) into the spout
tube (E). Be sure not to damage o-rings.
Refer to valve trim number and page P99061A to determine proper valve installation specifications.
Proceed to step 7
Step 5.4
Step 7
Once spout is flush against the wall secure in place with
setscrew (J). Proceed to step 6.
Once the finished wall is in place, attach o-rings (K), escutcheons (L), wear washers (M), and handles (N), to the
valve stems. Secure handle with setscrew (P)
If the valve stem is too short to accept handle see step 7.1
If the valve stem is too long see step 7.2 and 7.3.
Page 3
P99061
Step 7.1
Step 7.3
Remove handle, escutcheon and stern assembly (#6)
Make appropriate cuts on sterm (#4) and nipple (#5).
Reinstall stern assemblies, escutcheons and handles.
If the valve is installed too deep behind the wall, extension
stems are available. Please contact your local distributor
to order part number EXTWALL65_001
Step 7.2
Step 7.4
15
14
13
HANDLE CLEARANCE
If the valve is installed too far out of the wall the stems
and nipples may be trimmed. to determine amount to be
cut measure the gap between the escutcheon and the
wall and/or the gap between the handle and escutcheon,
Attach handle (14) to handle escutcheon (13). Tighten
spacer nut (15) into the handle (14) so that there is clearance
(~1/13”) between the handle (14) and the handle base (13).
See clearance diagram above.
Page 4
P99061
Step 7.5
Step 7.6
16
18
17
14
13
14
Secure handle (14) to the handle escutcheon (13) by
tightening the cap screw (16) into the valve stem.
Complete the handle installation by placing the o-ring (17)
and decorative cover plate (18) into the recess in the
handle (14).
Page 5
P99061 (5/09)