Flex-Geko - Teknocalor Oy
Transcription
Flex-Geko - Teknocalor Oy
Lovely and flexible | Fan Coil Units GEA Flex-Geko ® Solutions for all demands | Basic and Comfort [21 °C] 32 dB(A) Air Treatment GEA Flex Fan Coil Units Heating, cooling, and ventilating – fast and efficiently Unlike radiators and classical flat radiators, fan coil units not only can heat rooms, but can also cool and ventilate them. With 2-litre units, seasonal switch-over from heating to cooling operations is possible, and vice-versa (by reversing the medium supply). The 4-litre units additionally offer connections for heating and cooling circulation systems, and therefore allow spontaneous change-over between the modes of operation. Fan coil units actively direct the air to be treated through the heat exchanger, with especially effective heating or cooling. They bring room air to the desired temperature faster and operate with smaller heating or cooling surfaces. Their enhanced heat transfer enables lower feed temperatures during heating, and higher feed temperatures during cooling. This minimises losses and saves energy between the boiler or the chiller and the final unit. A choice of fan speeds, as well as valves to regulate the flow volume, enable flexible control of unit output. Adjustable air-outlet grills, in addition, assure uniform distribution of temperatureComfortable climate-control solution: controlled air in the room. Heating and cooling in one unit Test e 6 02 2 VDI (D) units e d Assuring desired room temperature with smaller m-air hygie o n ro 2 ted by I LH RL Te s 01 104 - IN ene i g y of h VA l a e I S S W K ( CH ) Energy saving with lower feed temperatures during heating, and with higher temperatures for cooling Flexible control Recirculated-air units in accordance with VDI 6022 BE PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 Our models in the Basic and Comfort Editions The right version for every requirement The GEA Flex fan coil units are available in the Basic and Comfort Editions. Both of these variations are based on the same equipment platform, and employ this platform with various system components. This enables numerous equipment configurations. Purity and timeless design – the Basic variation The Basic Edition model, with modest grey-white enclosure, contains high-quality technology and offers (according to version) connections for hot and/or cold water, a three-speed fan, and an air filter. Various valve types allow coordinated and precise heating and cooling. With its extremely user-friendly control system, the GEA Flex fan coil unit is therefore the perfect starter model for comfortable, decentral climate control of your rooms. Greater expectations in many variations – the Comfort Edition The basic edition of the GEA Flex fan coil unit offers reliable technology for many applications. This starter unit is well suited for user-friendly heating and/or cooling, and can be combined with various accessory components. The Comfort Edition of the GEA Flex offers additional functions and more features. It enables climate control of rooms in mixedair operation, and treatment of the air with finer filters. According to the requirements, Comfort units offer hot and/or cold water connections. They can be equipped with additional electrical heating, and with an integrated direct evaporator – which allows a combination with outdoor split-climate units. The enclosure is designed for various air-intake and -outlet variations, and a light-grey band makes the unit optically even slimmer. Installation sizes and diversity of performance Both GEA Flex variants, Basic and Comfort, are available in 8 installation sizes with a height beginning at 504 mm, and a uniform depth of 240 mm. The width will vary according to output, between 840 and 1,890 mm. The 8 unit sizes allow a selection that optimally matches the required output. The heating and The Comfort Edition, with its distinctive light-grey band, can climate-control rooms in mixed-air operation as well. It can be equipped with an additional electrical heater if required. Its various air-intake and -outlet directions guarantee flow-optimised airflow routing for all applications. cooling output ratings lie between 1 and 20 kW*. The circulating air volume coordinated to these output ratings varies between 150 and 1,800 m³/h. * Heating: pumped hot water, 70/50°C, tL1 +20°C * Cooling: pumped cold water, 6/12°C, tL1 +27°C, 46% relative humidity PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 3 Equipped for virtually every use With GEA Flex fan coil units, you can flexibly plan for every application As a result of their modular concept, GEA Flex fan coil units can be employed for many and various applications. These models are effective with wall or ceiling installation. They function highly satisfactorily on a stand-alone basis with enclosure, or can be mounted virtually invisibly as base units, with the required air outlets, behind a wall or above a suspended ceiling. The GEA MATRIX control system, integrated as desired, adapts to each and every functionality. The operator control units – with or without integrated timer switches – provide the interface to the user. The control units can be installed in the units themselves, or externally. Satisfies virtually all requirements: Flex units with primary-air connection can be easily combined with a central ventilation system. The control interfaces likewise Flexible setup and installation variations allow uncomplicated integration into the building-services man- Integration possible behind walls or above agement system. suspended ceilings The GEA MATRIX control system, adapted to the required functionalities rooms, and public facilities. Prominent hotel chains use them Integration into the building-services management system via various interfaces 4 gladly owing to their quiet and reliable operation. With their cost-effective operation and flexible application possibilities, Combination with other fan coil units or GEA products GEA Flex fan coil units heat, cool, and ventilate offices, sales GEA Flex fan coil units set standards for advanced climate-control solutions. PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 Wall and ceiling models Basic Edition Already with the Basic Edition of GEA Flex fan coil units, the most common requirements for climate control of rooms can be quietly and reliably satisfi ed. These robust units are highly effective for typical flush-mounted applications. The Basic Edition has been designed for heating or cooling in recirculated-air Only recirculated-air operation mode. It is effective for all applications for Basic model shown here: which a standard flush-mounted situation – without enclosure exists: for example, under windows. The – ceiling version horizontal ceiling installation is ideally – four-pipe system suited, for example, for shops, workshops, – valves mounted and other rooms where floor space is at a premium. Wall and ceiling models Comfort Edition The Comfort Edition of GEA Flex fan coil units satisfies requirements, for example, in which mixed-air options are desired – or where quiet heating and cooling are expected. They are also ideally suited for cases in which exceptional installation situations prevail. The many possible intake- and outlet-air combinations, and the extremely quiet fans, mean that Comfort Edition models are something special. The possibility of ordering these models with mixed-air operation, and/or with electrical heating, expands their application spectrum. In adRecirculated- or mixed-air operation dition, the great diversity of accessories Basic mixed-air model shown here: and the availability of various control – without enclosure modules all mean that the Comfort Edi- – wall version tion satisfies practically all situations. – four-pipe system – valves mounted PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 5 Whether at home, at work, or in a hotel: GEA fan coil units reliably assure feel-good room climate. High-performance fans take the room quickly to the desired temperature, and quietly maintain it at the required level. Basic or Comfort > the requirement decides [One equipment platform] [8 installation sizes] [2- and 4-pipe systems] [150 – 1,800 m³/h] [1 – 20 kW] [Heating, cooling, and ventilation] With high-performance functions for feel-good climate 6 PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 GEA Flex Fan Coil Units Enclosures 1 Air intake on the narrow side; air outlet on the narrow side. For recirculated-air operation with wall or ceiling installation. Free air suction required approx. 10 cm from the building. Without feet. Air intake on the narrow side; air outlet on the front side. For recirculated-air operation with wall or ceiling installation. Free air suction required approx. 10 cm 1 from the building. Without feet. Air intake on the front side; air outlet on the narrow side. For recirculated-air operations with wall, ceiling, or floor installation. For setup open in the room: with optional back wall or narrow-side cover panel. Intake-air opening with grill integrated into the enclosure. Without feet. 4 Air intake on the front side; air outlet on the front side. For recirculated-air operations with wall, ceiling, or 4 floor installation. Intake-air opening with grill integrated into the enclosure. Without feet. 5 Air intake on the front side; air outlet on the narrow side. For recirculated-air operations with wall, ceiling, or floor installation. With feet – intake-air opening without grill. 6 Air intake on the front side – air outlet on the front side. For recirculated-air operations with wall, ceiling, 5 or floor installation. With feet. Intake-air opening 6 without grill. 7 Air intake on the front side – air outlet on the narrow side. For recirculated- or mixed-air operations with wall, ceiling, or floor installation. With feet. Mixed-air intake opening integrated with grill. Intake of outside air on the rear side, without grill. 8 Air intake on the front side – air outlet on the front side. For recirculated- or mixed-air operations with 7 wall, ceiling, or floor installation. With feet. Mixed-air 8 intake opening integrated with grill. Intake of outside air on the rear side, without grill. 4 1 5 6 7 PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 8 7 GEA MATRIX – intelligent control technology Just the right turn for the right room climate If requested as option, the proven GEA MATRIX control unit will be integrated into the GEA Flex fan coil units at the factory. Your benefit: only completely tested equipment will be supplied to your construction site. GEA MATRIX is available in configuration levels 500, 2000, 3000, or 4000, with adaptation to the various possible applications. A version can be supplied for hotel applications, for example: as well as Comprehensive control possibilities: a Basic version for cost-optimised budgets. Control functions in various expansion stages Most of the versions are provided as default with the two-cable GEA Bus interfaces to other equipment units MATRIX dual-cable bus system, through which all GEA MATRIX Plug-and-play functionality units can communicate with each other. As a result, it is simple to Energy-optimised equipment operation implement daytime and nighttime switching actions, or to control Equipment ready to operate pumps and collect error messages at a single point. GEA MATRIX Highly competent service can also be connected to higher-level bus systems. Global add-on modules LON interface In addition, GEA MATRIX assures energy-optimized operation of Service tool GEA Flex fan coil units. A coordinated switch-over function, for example, prevents heating and cooling circulation systems from working against each other. By means of the summer compensation function, GEA MATRIX takes outside-temperature influences into account and prevents energy-intensive climate control. Hardware and software are developed entirely at GEA. As a result of close collaboration in the company, GEA engineers can systematically adjust the control system to match every component – and in turn optimally exploit the possibilities of the fan coil units. GEA support staff also profit from this arrangement by being able to quickly and expertly react in case of any questions. Numerous additional global modules are available as function expansions of the standard local connections. Examples here are: intra-group GEA MATRIX control units and clock modules, modules for activation control of exhaust-air fans and chillers, expansion of analogue or digital input and output signals, 0 … 10-V outputs for valves, and integration into a LON bus system in accordance with the LonWorks standard. Starting with MATRIX 2000, all modules can be simply integrated via the MATRIX.Net bus system. In addition, the service tools MATRIX.PDA and MATRIX.PC can be used for parameterisation, facility commissioning, maintenance, and data recording from the MATRIX control system. 8 PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 Control unit for MATRIX 500 Control unit for MATRIX 2000 MATRIX OP5 MATRIX OP21 – Enclosure without display, pure white – Recirculated-air mode, IP 20 protection class – D esired-temperature setting – Fan-speed selection for permanent duty – Button for temperature-reduction mode – L ED for operation/malfunction/ext. influence –Integrated room-temperature sensor Same as the OP5 control unit, but with: – Fan-speed selection switch for permanent / automatic operation – M ATRIX.Net data bus Network connection for MATRIX add-on modules via OP21 control unit Control units for MATRIX 3000 and MATRIX 4000 MATRIX OP30 without buttons MATRIX OP31 with temp.-reduction button MATRIX OP44 – Enclosure without display, pure white Same as the OP31 control unit, but with: – Recirculated-air, IP 20 protection class – S election switching for heating / cooling / automatic operation – D esired-temperature setting – Fan-speed selection switch for permanent / automatic operation – L ED for operation/malfunction/ext. influence – I ntegrated room-temperature sensor – S election switching for recirculated-air / mixed-air modes of operation All units without display. Protective hood as option. MATRIX OP50 without clock MATRIX OP51 with clock MATRIX.IR infrared remote control unit – Enclosure without display, pure white – IP 20 enclosure protection class – Functions as for the OP44 control unit, but: Without operational/malfunction reports Without report of external influence Without integrated room sensor – Operation by rotary navigator – Black enclosure, similar to RAL 9004 – LCD display with plain text – LCD display, 45 x 30 mm – Status report by pictograms – Effective range = approx. 20 m – Recirculated-air / mixed-air modes of operation – Integrated room-temperature sensor GEA thermostat / compact switch units CMS / CMT / CET series: extremely simple control units are also available for minimal control-function requirements (for systems based on pumped hot water and pumped cold water). PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 9 Overview of systems and performance ratings Basic Edition Installed sizes Fan speeds 1 - 2 - 3 1 ... 8 Recirculated air Typ Performance rating GEA Flex-Geko Air flow in m3 / h Heating rating in kW Cooling rating in kW min | max min | max min | max Pumped hot water / pumped cold water Heating with pumped hot water U0W Cooling with pumped cold water 1 UW0 Cooling with pumped cold water or heating with pumped hot water (change over) UWC Cooling with pumped cold water and heating with pumped hot water (4-pipe system) UWW 180 | 1800 1 2.0 | 19.5 180 | 1800 1.1 | 10.7 180 | 1800 2.0 | 19.5 1.1 | 10.7 175 | 1780 0.7 | 7.0 1.1 | 9.1 Installed sizes 1 ... 8 Air flow in m3 / h Heating rating in kW Cooling rating in kW Performance rating min | max min | max min | max 1 1 See pages 12 and 13 for the output ratings in the individual fan-speed levels. Comfort-Edition Fan speeds 1 - 2 - 3 Recirculated air / mixed air Typ Pumped hot water / pumped cold water Heating with pumped hot water U0W / M0W Cooling with pumped cold water 1 UW0 / MW0 Cooling with pumped cold water or heating with pumped hot water (change over) UWC / MWC Cooling with pumped cold water and heating UWW / MWW with pumped hot water (4-pipe system) 150 | 1820 1 1 1 1.7 | 19.6 150 | 1820 1.0 | 10.8 150 | 1820 1.7 | 19.6 1.0 | 10.8 145 | 1800 0.6 | 7.2 1.0 | 9.1 270 | 1820 2.1 | 12.4 Pumped hot water / pumped cold water / electrical heating Electrical heating U0E / M0E 1 Heating with pumped hot water + 1 U0F / M0F 220 | 1820 electrical booster heating 2.3 | 18.1 0.9 | 4.1 Cooling with pumped cold water or heating UWB / MWB 220 | 1820 1 with pumped hot water + electrical heating 2.3 | 18.1 0.9 | 4.1 1.2 | 9.6 Cooling with pumped cold water and heating with electrical heating 220 | 1820 0.9 | 4.1 1.2 | 9.6 Cooling and heating with cold and hot water UWF 1 215 | 1800 (4-pipe system) + electrical heating (only recirculated air) 0.9 | 7.2 0.9 | 4.1 1.2 | 7.6 UWE / MWE 1 Refrigerant: R410A / pumped hot water Cooling with R410A refrigerant 1 UD0 / MD0 Cooling with R410A refrigerant and 1 UDW / MDW heating with pumped hot water 270 | 1820 1.2 | 7.1 270 | 1800 1.0 | 4.9 1.0 | 7.2 Heating with pumped hot water: 70/50°C, tL1 +20°C; cooling with pumped cold water: 6/12°C, tL1 +27°C, 46% relative humidity; refrigerant: R410A, to +10°C · See page 11 for data on the sound emission *The “U”s in the “Type” column above stand for recirculated air. “M” stands for mixed air 10 PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 GEA Flex-Geko Noise emission in dB(A) Basic Edition – installed sizes Fan speeds 1 - 2 - 3 1 2 3 4 5 6 7 8 m3 / h 180 190 330 380 400 520 570 590 Acoustic power level Lw 33 33 33 35 35 36 36 36 Acoustic pressure level* Lp * 24 24 24 26 26 27 28 27 m3 / h 260 290 490 540 560 740 790 940 Acoustic power level Lw 41 43 44 44 44 44 45 45 Acoustic pressure level* Lp * 33 34 35 35 35 35 36 37 m3 / h 490 520 860 960 990 1310 1410 1800 Acoustic power level Lw 57 57 59 60 60 62 62 63 Acoustic pressure level* Lp * 48 49 51 51 51 54 53 54 3 4 5 6 7 8 300 430 460 590 At air flow of: At air flow of: At air flow of: Fan speed 1 Fan speed 2 Fan speed 3 Comfort Edition – installed sizes 1 2 Fan speeds 1 - 2 - 3 - 4 - 5 At air flow of: Fan speed 1 m3 / h 150 160 280 290 Acoustic power level Lw <30 <30 30 <30 <30 33 33 34 Acoustic pressure level* Lp * 21 <20 21 20 <20 24 24 25 m3 / h 270 280 470 490 520 750 770 970 Acoustic power level Lw 42 42 43 41 42 46 46 46 Acoustic pressure level* Lp * 33 33 34 32 34 38 38 37 m3 / h 530 540 890 990 1010 1310 1420 1820 Acoustic power level Lw 58 58 59 58 59 62 62 61 Acoustic pressure level* Lp * 50 49 51 50 51 54 53 53 At air flow of: At air flow of: Fan speed 3 Fan speed 5 * Conditions for measurement of acoustic pressure level Lp: Measuring interval = 5 m. Room volume = 100 m³. Reverberation period = 0.5 s. Directional factor = 4 (quarter-sphere sound emission) PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 11 Performance ratings Basic Edition 1 Capacity stage Basic Edition Installed size 1 Min. fan-speed level = 1 2 3 4 5 6 7 8 2 pipes Air flow m3 / h 180 190 330 380 400 520 570 590 Heating U0W / UWC kW 2.0 2.3 3.6 4.3 4.7 5.6 6.3 6.8 Cooling UW0 / UWC kW 1.1 1.2 1.9 2.4 2.7 3.0 3.4 3.7 4 pipes Air flow m3 / h 175 185 325 370 390 515 565 585 Heating UWW kW 0.7 1.1 1.8 2.3 2.5 3.2 3.7 3.9 Cooling UWW kW 1.1 1.2 2.0 2.4 2.5 3.3 3.7 3.8 1310 1410 1800 10.5 11.6 14.3 5.2 5.9 7.2 Max. fan-speed level = 3 2 pipes Air flow m3 / h 490 520 860 960 990 Heating U0W / UWC kW 3.8 4.6 6.7 7.9 8.8 Cooling UW0 / UWC kW 1.9 2.3 3.4 4.1 4.6 4 pipes Air flow m3 / h 485 515 850 945 975 1300 1395 1780 Heating UWW kW 1.4 1.9 3.0 3.7 4.2 5.3 5.9 7.1 Cooling UWW kW 1.9 2.2 3.5 4.2 4.4 5.7 6.3 7.2 7 8 Basic Edition 2 Capacity stage Installed size 1 Min. fan-speed level = 1 2 3 4 5 6 2 pipes Air flow m3 / h 175 185 325 370 390 515 565 585 Heating U0W / UWC kW 2.2 2.6 4.2 5.0 5.4 6.7 7.4 7.9 Cooling UW0 / UWC kW 1.2 1.5 2.3 2.8 3.2 3.5 4.1 4.5 4 pipes Air flow m3 / h 170 185 310 345 370 500 545 570 Heating UWW kW 0.9 1.2 1.9 2.2 2.5 3.0 3.4 3.7 Cooling UWW kW 1.1 1.4 2.1 2.6 2.9 3.3 3.7 4.1 1300 1395 1780 13.1 14.6 17.9 6.8 7.7 Max. fan-speed level = 3 2 pipes Air flow m3 / h 485 515 850 945 975 Heating U0W / UWC kW 4.7 5.6 8.5 9.9 10.8 Cooling UW0 / UWC kW 2.4 3.1 4.4 5.4 4 pipes Air flow m3 / h 470 505 815 890 920 1255 1350 1700 Heizen UWW kW 1.6 2.2 3.3 3.9 4.4 5.1 5.8 7.0 Cooling UWW kW 2.2 2.9 4.2 5.0 5.6 6.4 7.3 9.1 7 8 Basic Edition 3 Capacity stage Installed size 1 Min. fan-speed level = 1 6.0 2 3 4 5 6 9.6 2 pipes Air flow m3 / h 170 185 310 345 370 500 545 570 Heating U0W / UWC kW 2.4 2.6 4.4 5.0 5.4 6.8 7.6 8.1 Cooling UW0 / UWC kW 1.3 1.5 2.5 2.9 3.3 3.5 4.1 4.6 890 920 1255 1350 1700 14.3 15.8 19.5 7.6 8.6 10.7 Max. fan-speed level = 3 2 pipes Air flow m3 / h 470 505 815 Heating U0W / UWC kW 5.2 6.0 9.4 Cooling UW0 / UWC kW 2.9 3.3 5.2 10.6 11.6 6.0 6.5 Heating with pumped hot water: 70/50°C, tL1 +20°C; cooling with pumped cold water: 6/12°C, tL1 +27°C, 46% relative humidity 12 PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 Comfort Edition Comfort Edition 1 Capacity stage Performance ratings Installed size 1 Min. fan-speed level = 1 2 3 4 5 6 7 8 2 pipes Air flow m3 / h 150 160 280 290 300 430 460 590 Heating U0W / UWC kW 1.7 2.0 3.2 3.5 3.7 4.9 5.4 6.8 Cooling UW0 / UWC kW 1.0 1.1 1.7 2.0 2.1 2.6 2.9 3.7 4 pipes Air flow m3 / h 145 155 275 285 295 425 455 575 Heizen UWW kW 0.6 1.0 1.7 1.9 2.1 2.9 3.2 3.9 Cooling UWW kW 0.9 1.0 1.8 2.0 2.0 2.8 3.2 3.7 Max. fan-speed level = 5 2 pipes Air flow m3 / h 530 540 890 990 1010 1310 1420 1820 Heating U0W / UWC kW 3.9 4.7 6.8 8.1 8.8 10.5 11.7 14.4 Cooling UW0 / UWC kW 2.0 2.4 3.4 4.1 4.7 5.2 5.9 7.3 4 pipes Air flow m3 / h 525 535 880 980 1000 1295 1405 1800 Heating UWW kW 1.4 2.0 3.1 3.7 4.2 5.3 5.9 7.2 Cooling UWW kW 2.0 2.3 3.5 4.3 4.5 5.7 6.4 7.3 7 8 Comfort Edition 2 Capacity stage Installed size 1 Min. fan-speed level = 1 2 3 4 5 6 2 pipes Air flow m3 / h 145 155 275 285 295 425 455 575 Heating U0W / UWC kW 1.9 2.2 3.7 4.0 4.3 5.7 6.2 7.8 Cooling UW0 / UWC kW 1.0 1.3 2.1 2.3 2.6 3.0 3.5 4.4 4 pipes Air flow m3 / h 145 155 265 280 290 415 445 545 Heating UWW kW 0.8 1.0 1.7 2.0 2.1 2.7 3.0 3.6 Cooling UWW kW 1.0 1.2 1.9 2.2 2.4 2.7 3.1 4.0 Max. fan-speed level = 5 2 pipes Air flow m3 / h 525 535 880 980 1000 Heating U0W / UWC kW 5.0 5.8 8.8 10.1 11.0 Cooling UW0 / UWC kW 2.5 3.1 4.5 5.5 6.1 4 pipes Air flow m3 / h 510 525 845 950 Heating UWW kW 1.7 2.2 3.3 4.0 4.5 5.1 5.8 7.0 Cooling UWW kW 2.3 3.0 4.3 5.2 5.8 6.4 7.4 9.1 7 8 Comfort Edition 3 Capacity stage Installed size 1 Min. fan-speed level = 1 2 3 4 1295 975 13.1 1405 6.8 1245 14.6 18.1 7.8 9.6 1360 5 6 1800 1710 2 pipes Air flow m3 / h 145 155 265 280 285 415 445 545 Heating U0W / UWC kW 2.0 2.2 3.8 4.1 4.3 5.7 6.4 7.7 Cooling UW0 / UWC kW 1.2 1.3 2.2 2.4 2.6 3.1 3.4 4.4 Max. fan-speed level = 5 2 pipes Air flow m3 / h 510 525 845 950 970 1245 1360 1710 Heating U0W / UWC kW 5.5 6.2 9.6 11.1 12.0 14.2 15.9 19.6 Cooling UW0 / UWC kW 3.0 3.4 5.3 6.2 6.7 7.6 8.7 10.8 Heating with pumped hot water: 70/50°C, tL1 +20°C; cooling with pumped cold water: 6/12°C, tL1 +27°C, 46% relative humidity. Models with different output ratings are available upon request for systems with electrical heating and direct evaporators. PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 13 Base units – dimensions and weights (mass) Recirculated air mm Comfort Mixed air mm mm Height Height Width 1 470 596 2 470 3 GEA Flex-Geko mm Basic weight kg Comfort weight kg Depth Max Max 761 225 ... 237 13 18 596 911 225 ... 237 14 22 470 596 1061 225 ... 237 18 27 4 470 596 1211 225 ... 237 21 32 5 470 596 1361 225 ... 237 24 36 6 470 596 1511 225 ... 237 28 42 7 470 596 1661 225 ... 237 30 46 8 470 596 1881 225 ... 237 35 52 Installation sizes Wall units 225 471 Recirculated air – Basic and Comfort 225 (228**) 35 108 471 125 Mixed air – Comfort Edition The dimensions of the recirculated-air unit with 125-mm supporting feet are the same as those of the mixed-air unit. Enclosures – dimensions and weights (mass) Recirculated air mm Comfort Mixed air mm mm Basic weight kg Comfort weight kg mm Height Height Width Depth Max Max 1 504 629 840 240 9 9 2 504 629 990 240 10 10 3 504 629 1140 240 11 11 4 504 629 1290 240 12 12 5 504 629 1440 240 13 13 6 504 629 1590 240 14 14 7 504 629 1740 240 15 15 8 504 629 1890 240 16 16 Installation sizes Enclosures Basic and Comfort Editions Recirculated-air wall unit 240 1 504 Without feet; without intakeair grill 240 5 504 629 125 The dimensions of the recirculated-air unit with 125-mm supporting feet are the same as those of the mixed-air unit. With feet; without intake-air grill 240 7 504 104 629 125 With feet; with intake-air grill Enclosures Comfort Edition Enclosures Comfort Edition Recirculated-air wall unit 4 240 Mixed-air wall unit 240 6 120 240 7 240 8 120 120 504 504 92 504 629 629 125 125 Without feet; with intake-air grill in the enclosure 14 104 With feet; without intake-air grill With feet; with intake-air grill Air outlet on narrow side 504 104 629 125 With feet; with intake-air grill Air outlet on front side PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 GEA Flex-Geko Enclosures without supporting feet Intake-air and outlet-air variations Wall and ceiling models Comfort • I Basic Δ RecirculatedO utlet-air grill O utlet-air grill air-units of plastic of aluminium For views, see page 7 Adjustable Not adjustable Intake narrow side | Outlet narrow side 1 4 Intake narrow side | Outlet front side 2 Intake front side | Outlet narrow side 3 Intake front side | Outlet front side 4 Intake front side | Outlet narrow side | With cover panel 3 Intake front side | Outlet narrow side | With rear-wall panel 3 Enclosures with supporting feet Intake-air and outlet-air variations Wall and ceiling models Comfort • I Basic Δ Mixed-air RecirculatedO utlet-air grill O utlet-air grill units air-units of plastic of aluminium For views, see page 7 Adjustable Not adjustable 5 Intake front side | Outlet narrow side | Without intake grill Intake front side | Outlet front side 6 | Without intake grill 7 Intake front side | Outlet narrow side | With intake grill Intake front side | Outlet front side 8 | With intake grill Accessories Accessories Air-intake side Wall and ceiling models Comfort • I Basic Outlet-air side Wall and ceiling models Δ Comfort • I Basic Δ Intake-air box with primary-air fittings Outlet-air box with primary-air fittings, not insulated Intake-air box with round intake fittings Outlet-air box with primary-air fittings, insulated DN 200 enclosure cover for round fittings Outlet-air box with round outlet-air fittings, not insulated Intake-air bend Outlet-air box with round outlet-air fittings, insulated Intake-air sailcloth fittings DN 200 enclosure cover for round fittings Connection piece for intake-air sailcloth fittings Air-outlet bend, not insulated Intake-air telescopic fittings Air-outlet bend, insulated Intake-air noise suppressor for recirculated-air Outlet-air sailcloth fittings Intake-air noise suppressor for mixed-air units Telescopic outlet-air fittings Built-in wall frame for fresh-air fittings Outlet-air noise-suppressor fittings Weather-protection grill, RAL 9002, painted Built-in wall frame for weather-protection grill Spare filter, G1 Spare filter, G2, G3 Image brochure Application brochures Product brochures Data & Facts and operation manuals (available only as PDF) You are on this level of our documentation structure. You can order at no charge from the first 3 levels as printed copies, under: [email protected]. You can download all brochures as PDF files from the following Internet site: www.gea-airtreatment.com. PR-2008-0305-GB • We reserve the right to make changes without notice • Version: 09/2008 15 Customer proximity, sales structures Reachable always and everywhere! GEA Happel Belgium N. V. B-1130 Brussels Tel. +32 / 2 / 2406161 D EVISS Ltd. BG-7000 Rousse Tel . +359 / 82 / 81000 BIH GEA Klimatechnik GmbH & Co KG RS-11070 Novi Beograd Tel. +381 / 11 / 3193955 BY GEA Klimatechnik UAB LT-01141 Vilnius Tel. +370 / 5 / 2106060 CH ATC Klimatec Schweiz AG CH-3065 Bolligen-Station Tel. +41 / 31 / 9171919 CZ GEA Klimatizace spol. s r.o. CZ-46312 Liberec Tel. +420 / 48 / 5225-303 D GEA Happel Klimatechnik GmbH D-44625 Herne Tel. +49 / 2325 / 468-00 D D GEA Happel Wieland GmbH D-44625 Herne Tel. +49 / 2325 / 468-754 GEA Deichmann Umwelttechnik GmbH D-36179 Bebra Tel. +49 / 6622 / 504-0 GEA Delbag-Luftfilter Vertriebsgesellschaft mbH D-10709 Berlin Tel. +49 / 30 / 43592-3 DK GEA Klimateknik ApS DK-2610 Rødovre Tel . +45 / 38 / 887070 E GEA Air Treatment Marketing Services Int. GmbH – oficina España E-28036 Madrid Tel. +34 / 91 / 3837701 EST GEA Klimatechnik UAB LT-01141 Vilnius Tel. +370 / 5 / 2106060 F GEA LVZ, a.s. CZ-46312 Liberec Tel. +420 / 48 / 5225-111 CZ GEA Delbag Lufttechnik GmbH D-44625 Herne Tel. +49 / 2325 / 468-700 F GEA Delbag Filtration de l‘air F-77450 Montry Tel. +33 / 1 / 60043355 GEA Happel France sarl F-59436 Roncq Cedex Tel. +33 / 3 / 20689020 FIN OY TEKNOCALOR AB FIN-01300 Vantaa Tel. + 358 / 10 / 8201100 GB GEA Denco Ltd. UK-HR4 8DS Hereford Tel. +44 / 1432 / 277 277 H HR IE GEA Klimatechnika Kft H-1037 Budapest Tel. +36 / 1 / 4393200 P Nónio, Lda. P-1269-090 Lisboa Tel. +351 / 21 / 3826160 GEA Klima-rashladna tehnika d.o.o. HR-10000 Zagreb Tel. +385 / 1 / 6064900 PL GEA Klimatyzacja Sp. z o.o. PL-54610 Wroclaw Tel. +48 / 71 / 3737952 RO GEA Klimatechnik s.r.l. RO-300222 Timisoara Tel. +40 / 356 / 423703 Aspect Environmental Ltd. Ardee, Co. Louth Ireland Tel. +353 / 41 / 6858983 IS Rafn Jensson IS-110 Reykjavik Tel. +354 / 56 / 780-30 L GEA Happel Luxembourg L-4940 Bascharage Tel. +352 / 26 / 502970 LT LV GEA Klimatechnik UAB LT-01141 Vilnius Tel. +370 / 5 / 2106060 GEA Klimatechnik UAB LT-01141 Vilnius Tel. +370 / 5 / 2106060 MWE GEA Klimatechnik GmbH & Co KG RS-110 70 Novi Beograd Tel. +381 / 11 / 3193955 RUS GEA Klimatechnik GmbH & Co KG RU-105094 Moskva Tel. +7 / 495 / 9566674 S SK GEA EXOS Ventilation AB S-74528 Enköping Tel. +46 / 171 / 85530 GEA Klimatizácia s.r.o. SK-83104 Bratislava Tel. +421 / 7 / 44457917 SLO GEA Klimatizacijska Tehnika d.o.o. SI-1000 Ljubljana Tel. +386 / 1 / 2573850 SRB GEA Klimatechnik GmbH & Co KG RS-11070 Novi Beograd Tel. +381 / 11 / 3193955 TR N GEA Klimaprodukter AS N-0484 Oslo Tel. +47 / 220 / 27990 NL GEA Happel Nederland B.V. UA NL-2909 LL Capelle a/d Ijssel UAE Tel. +31 / 10 / 2350606 GEA ISISAN TR-80700 Balmumcu Istanbul Tel. +90 / 212 / 2757171 GEA Ukraina t.o.v. UA-01135 Kyiv Tel. +38 / 044 / 4619356 GEA Air Treatment Middle East UAE-Dubai Tel. +971 / 4 / 887 3881 Test e ro om - a i r hy g 6022 ie (D ) ne d The complete addresses are available on the Internet under: www.gea-air-eco2nomy.com. e gien of hy Seal SWKI V(CAH) VDI Te s 10 4- ted 01 by I LH www.gea-air-eco2nomy.com BE PR - 2008-0305-GB • Subject to modification Issue 09/2008 • Copyright GEA Air Treatment BG D IN B GEA Klimatechnik GmbH & Co KG A-4673 Gaspoltshofen Tel. +43 / 7735 / 8000-0 RL A