Wolf Heiztechnik
Transcription
Wolf Heiztechnik
Technical documentation TopWing Unit Heater TLH TLHK 1 TopWing Contents TLH / TLHK Contents......................................................................................................................Page Unit heaters TLH.....................................................................................................................................3 Unit heaters TLHK..................................................................................................................................4 Performance table, cooling, TLHK / Condensate drain................................................................5 Performance table, heating power, TLH 25 / TLHK 25, Type 4..................................................6 Performance table, heating power, TLH 40 / TLHK 40, Type 4..................................................7 Performance table, heating power, TLH 63 / TLHK 63, Type 4..................................................8 Performance table, heating power, TLH 100 / TLHK 100, Type 4..............................................9 Dimensions TLH / TLHK.......................................................................................................................10 Shut-off sets / Fixing accessories TLH / TLHK..............................................................................11 Fixing accessories TLH / TLHK.................................................................................................12 - 14 Discharge Accessories TLH......................................................................................................15 - 16 Intake Accessories TLH / TLHK................................................................................................17 - 19 Switchgear and Control Units TLH................................................................................................. 20 Switchgear TLH........................................................................................................................... 21 - 25 Switchgear for flap servomotors TLH/TLHK................................................................................. 24 Positioning drives for outdoor air and maxed air TLH.............................................................. 26 Room Thermostats TLH...................................................................................................................... 27 Thermostats, terminal box TLH....................................................................................................... 28 Control systems WRS for TLH.................................................................................................29 - 33 5-stage electronic switch for 0 - 10V TLH/TLHK....................................................................... 34 Room Thermostats TLHK................................................................................................................... 35 Thermostats, terminal box TLHK..................................................................................................... 36 Control systems WRS for TLHK..............................................................................................37 - 38 Planning information TLH / TLHK..........................................................................................39 - 42 Horizontal throw TLH......................................................................................................................... 43 Vertical throw TLH.............................................................................................................................. 44 Speeds table TLH................................................................................................................................. 45 Sound pressure levels TLH / TLHK................................................................................................... 46 Power as a function of accessories TLH........................................................................................ 47 Number of cores / Weights TLH / TLHK........................................................................................ 48 Texts for quoations TLH / TLHK..............................................................................................49 - 55 2 TopWing Unit heaters The TLH-series unit heaters were developed specifically for convenient heating. Various models are available, catering to the following applications: heating, ventilation or filtration. Each device can be used in conjunction with suitable accessories for recirculated-air, mixed-air or outdoor-air operation and mounted on the wall or ceiling. There are four different sizes for air flow rates up to 9000 m³/h and heating-power ratings up to 164 kW. TLH Cu/Al heat exchanger: The heating elements are large-size registers. The advantage of this arrangement is that discharge temperatures of approximately 36°C can be achieved even with low-temperature heating systems or highefficiency boiler systems with flow/return spreads of 50/40°C and maximum volume flow in recirculation mode. - 4 heat-exchanger types per unit-heater size for pressurized warm water (PWW) - Heat exchangers made of Cu/Al, manifolds steel or copper, pull out to the side for removal Housing: - Ports with inch-system threads for PWW - Welded, galvanized and powder-coated sectional frame - Threaded adapters for PN 16 up to 140°C - Skin panels made of sheet steel, powder-coated, color standard white RAL 9016, with bonded PU soft-foam insulation, 25mm thick - Water flow on air discharge side, top/bottom - Rear panel with deep-drawn intake nozzle, powder-coated, color standard white RAL 9016 - Connection side right/left in direction of air flow - Discharge louver with individually adjustable vanes, powder-coated, color Wolf silver, similar to RAL 9006 - Water return on air intake side, top/bottom - Connection sizes: see performance tables. Range of colors: Motor- fan guard unit: The motor/fan unit has a super-quiet cresent-wing rotor with a singlephase 230V AC or 3 x 400V motor. - Motor fan guard unit fitted on the back panel with antivibration mounts - Three-phase motor 3 x 400V, 50Hz Star wiring: low speed Delta wiring: high speed - Single-phase alternating-current motor 230V, 50Hz high speed only; lower speeds selectable by means of multistage switch. - Degree of protection IP54, heat class CLF - Grooved ball bearing with special grease lubrication for temperatures down to -40°C - Winding protection through integral thermal contacts; only effective in conjunction with a step switch and a control unit The housing of the TLH unit heater is normally finished in standard white (RAL 9016) and the discharge louver in Wolf silver (similar to RAL 9006). Other RAL colors are available on request. 3 TopWing Unit heater The TLHK-series unit heaters were developed specifically for convenient heating or cooling. Shey are suitable for heating or cooling. Each device can be used in conjunction with Each device can be used in conjunction with suitable accessories for recirculated-air or mixed-air and mounted on the wall. Air filtration is also possible with the relevant accessories. There are four different sizes for air flow rates up to 9000 m³/h and heating-power ratings up to 164 kW, or air flow rates up to 4280³/h im Kühlbetrieb und einer cooling-power ratings up to 37,5kW. TLHK Cu/Al heat exchanger: Large two-line heat exchangers (type 4) are used for heating or cooling. This has the benefit that in cooling mode, sufficient cooling capacity is available, and in heating mode with low temperature heating systems or condensing systems with flow/return spreads of 50/40 °C and a maximum flow rate in recirculation air mode, discharge temperatures of approx. 36 °C are reached. - Heat exchangers made of Cu/Al, manifolds steel or copper, pull out to the side for removal, threaded adapters for PN 16 up to 140°C - Connection side right/left in direction of air flow Housing: Range of colors: - Welded, galvanized and powder-coated sectional frame - Skin panels made of sheet steel, powder-coated, color standard white RAL 9016, with bonded PU soft-foam insulation, 25mm thick - Rear panel with deep-drawn intake nozzle, powder-coated, color standard white RAL 9016 - Integral condensate pan made of aluminium with a fall for complete draining - Unit with ½“ drain connector for free draining - Induction louvre with secondary air cone - Supply air sensor fitted and pre-wired Motor- fan guard unit: The motor/fan unit has a super-quiet cresent-wing rotor with a single-phase 230V AC or 3 x 400V motor.. -Motor fan guard unit fitted on the back panel with antivibration mounts - Motor fan unit pre-wired in the control unit - Degree of protection IP54, heat class CLF 4 The housing of the TLHK unit heater is normally finished in standard white (RAL 9016) and the discharge louver in Wolf silver (similar to RAL 9006). Other RAL colors are available on request. TopWingPerformance table, cooling TLHK Condensate drain For cold water Type 25 Motor power Speed [rpm] Vol. flow VO [m³/h] PKW 5/10 PKW 6/12 PKW 8/14 °C %r.F. 32 40 28 47 26 49 25 50 32 40 28 47 26 49 25 50 32 40 28 47 26 49 25 50 3 x 400V 750 940 tLA QO kW °C 7,2 15 5,9 14 5,1 14 4,7 13 6,3 16 5,0 15 4,2 14 3,8 14 5,4 17 4,1 16 3,4 15 3,1 15 Motor power [kW] (3 x 400 V) Consumption [A] (3 x 400 V) Motor power [kW] (1 x 230 V) Consumption [A] (1 x 230 V) Water capacity [L] Connections 40 1 x 230V 750 940 tLA QO kW °C 7,2 15 5,9 14 5,1 14 4,7 13 6,3 16 5,0 15 4,2 14 3,8 14 5,4 17 4,1 16 3,4 15 3,1 15 3 x 400V 800 1660 tLA QO kW °C 12,9 15 10,6 15 9,2 14 11,4 16 11,4 16 9,1 15 7,7 15 7,0 14 9,8 17 7,6 16 6,2 12 5,6 15 63 1 x 230V 600 1240 tLA QO kW °C 10,4 14 8,6 13 7,5 13 9,2 15 9,2 15 7,4 14 6,3 14 5,7 13 8,0 16 6,2 15 5,0 14 4,5 14 3 x 400V 550 2690 tLA QO kW °C 22,5 14 18,6 14 16,3 13 20,1 15 20,1 15 16,2 15 13,8 14 12,7 13 17,4 16 13,6 15 11,2 15 10,0 14 100 1 x 230V 500 2440 tLA QO kW °C 20,9 14 17,3 13 15,1 13 18,7 15 18,7 15 15,1 14 12,9 14 11,8 13 16,2 16 12,6 12 10,4 14 9,3 14 3 x 400V 500 4280 tLA QO kW °C 37,5 14 31,2 13 27,4 12 33,9 15 33,9 15 27,6 14 23,7 13 21,8 13 29,6 16 23,3 15 19,4 14 17,5 14 max. 0,18 max. 0,32 max. 0,34 max. 0,76 max. 0,40 max. 0,62 max. 0,85 max. 1,70 max. 0,20 max. 0,30 max. 0,40 - max. 0,90 max. 1,40 max. 1,80 - 1,8 R 1“ 2,5 R 1“ 5,5 R 1¼“ 9,5 R 1½“ TLHK with free drainage TLHK with free drainage: - Condensate hose to the drain connector - Fitted ½“ drain connector for connection to a ½“ drain hose 5 TopWing Performance table, heating power TLH 25 TLHK 25, Type 4 For warm water Type 1 Speed [min-1] Vol. flow VO [m³/h] PWW 45/35 PWW 50/40 PWW 60/40 PWW 70/50 PWW 80/60 Connections * At tLA - tRoom = 10K 6 1000 1700 tLA °C -2 2 6 10 13 17 21 24 0 4 8 11 15 19 22 26 0 4 7 11 15 18 22 26 3 7 10 14 18 22 25 29 6 10 14 17 21 25 29 32 QO tLE[°C] kW - 15 10,7 - 10 9,5 - 5 8,4 ± 0 7,2 + 5 6,1 + 10 5,0 + 15 4,0 + 20 2,9 - 15 11,9 - 10 10,7 - 5 9,5 ± 0 8,4 + 5 7,3 + 10 6,2 + 15 5,1 + 20 4,0 - 15 11,7 - 10 10,6 - 5 9,4 ± 0 8,3 + 5 7,2 + 10 6,1 + 15 5,0 + 20 4,0 - 15 14,1 - 10 13,0 - 5 11,8 ± 0 10,7 + 5 9,5 + 10 8,4 + 15 7,3 + 20 6,3 - 15 16,6 - 10 15,4 - 5 14,2 ± 0 13,0 + 5 11,9 + 10 10,7 + 15 9,6 + 20 8,5 Motor power [kW] (3 x 400 V) Consumption [A] (3 x 400 V) Motor power [kW] (1 x 230 V) Consumption [A] (1 x 230 V) Throw, wallmounted [m]* Throw, ceilingmounted [m]* Water capacity [L] 2 1350 2100 tLA °C 0 3 7 11 14 18 21 25 1 5 9 12 16 19 23 26 1 5 9 12 16 19 23 26 5 8 12 16 19 23 26 30 8 12 15 19 23 26 30 33 QO kW 9,5 8,5 7,4 6,4 5,5 4,5 3,5 2,6 10,5 9,5 8,5 7,5 6,5 5,5 4,5 3,6 10,4 9,4 8,4 7,4 6,4 5,5 4,5 3,6 12,6 11,5 10,5 9,5 8,5 7,5 6,6 5,6 14,7 13,6 12,6 11,6 10,6 9,6 8,6 7,6 3 1350 2000 1000 1600 tLA °C 5 8 11 15 18 21 24 27 7 10 14 17 20 23 26 29 7 11 14 17 20 23 26 29 12 15 18 21 25 28 31 34 16 19 23 26 29 32 35 38 QO kW 15,1 13,5 11,9 10,3 8,8 7,3 5,8 4,3 16,7 15,1 13,5 11,9 10,4 8,8 7,3 5,8 16,8 15,2 13,6 12,1 10,5 9,0 7,5 6,0 20,1 18,5 16,9 15,3 13,7 12,2 10,7 9,1 23,3 21,7 20,1 18,5 16,9 15,3 13,8 12,2 tLA °C 7 10 13 16 19 22 24 27 9 12 15 18 21 24 27 30 9 13 16 19 22 24 27 30 14 17 20 23 26 29 32 35 19 22 25 28 31 34 37 40 QO kW 13,2 11,8 10,4 9,1 7,7 6,4 5,1 3,8 14,6 13,2 11,8 10,4 9,1 7,7 6,4 5,1 14,7 13,3 12,0 10,6 9,3 7,9 6,6 5,3 17,6 16,2 14,8 13,4 12,0 10,7 9,4 8,0 20,4 18,9 17,5 16,1 14,8 13,4 12,1 10,7 4 1350 1800 1000 1450 tLA °C 11 14 17 19 22 24 27 29 14 17 19 22 25 27 29 32 15 17 20 23 25 28 30 32 20 23 26 28 31 34 36 38 26 28 31 34 37 39 42 44 QO kW 17,9 16,0 14,1 12,3 10,5 8,8 7,0 5,3 19,7 17,8 16,0 14,1 12,3 10,5 8,8 7,0 20,1 18,2 16,4 14,5 12,7 10,9 9,2 7,4 23,8 21,9 20,1 18,2 16,4 14,6 12,8 11,1 27,5 25,6 23,7 21,8 20,0 18,2 16,4 14,6 1350 1700 tLA °C 13 16 18 21 23 25 28 30 16 19 21 24 26 28 31 33 17 20 22 25 27 29 31 34 23 26 28 31 33 36 38 40 29 31 34 37 39 42 44 46 QO kW 15,5 13,9 12,3 10,7 9,2 7,6 6,1 4,6 17,1 15,5 13,9 12,3 10,7 9,2 7,7 6,2 17,5 15,9 14,3 12,7 11,1 9,6 8,1 6,5 20,7 19,1 17,5 15,9 14,3 12,7 11,2 9,7 23,8 22,2 20,6 19,0 17,4 15,8 14,3 12,7 1000 1350 tLA °C 20 22 23 25 27 29 30 32 23 25 27 29 31 32 34 36 24 26 28 30 32 33 35 37 31 33 35 37 39 41 43 44 38 40 42 45 47 48 50 52 QO kW 22,1 19,8 17,6 15,3 13,1 10,9 8,8 6,6 24,4 22,1 19,8 17,5 15,3 13,1 10,9 8,8 25,0 22,7 20,4 18,2 15,9 13,7 11,5 9,4 29,5 27,2 24,9 22,6 20,4 18,2 16,0 13,8 33,9 31,6 29,3 27,0 24,7 22,5 20,3 18,1 tLA °C 22 24 25 27 29 30 31 33 25 27 29 31 32 34 35 37 27 29 30 32 34 35 37 38 34 36 38 40 42 43 45 46 41 43 45 47 49 51 53 54 QO kW 18,7 16,8 14,9 13,0 11,1 9,3 7,5 5,7 20,5 18,6 16,7 14,8 12,9 11,1 9,3 7,5 21,2 19,3 17,4 15,5 13,6 11,7 9,9 8,1 25,0 23,0 21,1 19,2 17,3 15,5 13,6 11,8 28,6 26,6 24,7 22,8 20,9 19,1 17,2 15,4 max. 0,18 max. 0,18 max. 0,18 max. 0,18 max. 0,40 max. 0,40 max. 0,40 max. 0,40 max. 0,20 - max. 0,20 - max. 0,20 - max. 0,20 - max. 0,90 - max. 0,90 - max. 0,90 - max. 0,90 - 15,5 12,5 14,5 12 13 10,5 12,5 10 4,7 5,4 4,5 5,0 4,2 4,8 5,7 0,7 R ¾“ 1,0 R 1“ 1,1 R 1“ 4,0 1,8 R 1“ TopWing Performance table, heating power TLH 40 TLHK 40, Type 4 For warm water Type 1 Speed [min-1] Vol. flow VO [m³/h] PWW 45/35 PWW 50/40 PWW 60/40 PWW 70/50 PWW 80/60 tLE[°C] - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 Motor power [kW] (3 x 400 V) Consumption [A] (3 x 400 V) Motor power [kW] (1 x 230 V) Consumption [A] (1 x 230 V) Throw, wallmounted [m]* Throw, ceilingmounted [m]* Water capacity [L] Connections 2 1350 3500 1000 2500 tLA °C 0 4 7 11 15 18 21 25 2 5 9 13 16 20 23 27 2 6 9 13 16 20 23 27 5 9 13 16 20 23 27 30 9 12 16 20 23 27 30 34 QO kW 20,1 17,9 15,8 13,7 11,7 9,6 7,7 5,7 22,2 20,1 17,9 15,8 13,8 11,7 9,7 7,7 22,3 20,1 18,0 15,9 13,9 11,9 9,9 7,9 26,7 24,5 22,4 20,3 18,2 16,1 14,1 12,1 31,1 28,9 26,7 24,5 22,4 20,3 18,3 16,2 tLA °C 3 6 9 13 16 19 23 26 4 8 11 15 18 21 25 28 5 8 11 15 18 22 25 28 8 12 15 19 22 26 29 32 12 16 19 23 26 30 33 36 QO kW 16,5 14,8 13,1 11,3 9,7 8,0 6,4 4,8 18,3 16,5 14,8 13,1 11,4 9,7 8,0 6,4 18,4 16,7 14,9 13,2 11,6 9,9 8,3 6,6 22,0 20,3 18,5 16,8 15,1 13,4 11,7 10,1 25,6 23,8 22,0 20,2 18,5 16,8 15,1 13,4 3 1350 3400 1000 2400 tLA °C 4 7 10 14 17 20 23 26 6 9 12 16 19 22 25 28 6 9 13 16 19 22 25 28 10 13 17 20 23 27 30 33 14 17 21 24 28 31 34 37 QO kW 24,0 21,4 18,9 16,4 14,0 11,6 9,2 6,9 26,6 24,0 21,4 18,9 16,5 14,0 11,6 9,3 26,7 24,2 21,6 19,2 16,7 14,3 11,9 9,6 31,9 29,4 26,8 24,3 21,8 19,3 16,9 14,5 37,1 34,5 31,9 29,3 26,8 24,3 21,9 19,4 tLA °C 7 10 13 16 19 21 24 27 9 12 15 18 21 24 27 30 9 12 15 18 21 24 27 30 14 17 20 23 26 29 32 35 18 21 25 28 31 34 37 40 QO kW 19,5 17,4 15,4 13,4 11,4 9,5 7,5 5,7 21,5 19,4 17,4 15,4 13,4 11,4 9,5 7,6 21,8 19,7 17,7 15,7 13,7 11,8 9,8 7,9 25,9 23,9 21,8 19,8 17,8 15,8 13,8 11,9 30,1 27,9 25,9 23,8 21,8 19,8 17,8 15,9 4 1350 3100 1000 2200 tLA °C 12 15 17 20 22 25 27 29 15 18 20 23 25 28 30 32 16 19 21 24 26 29 31 33 21 24 27 30 32 35 37 39 27 30 33 35 38 41 43 46 QO kW 31,9 28,6 25,3 22,1 18,9 15,8 12,7 9,7 35,1 31,7 28,5 25,2 22,1 18,9 15,8 12,8 36,1 32,8 29,5 26,3 23,1 20,0 16,8 13,7 42,6 39,3 36,0 32,7 29,5 26,3 23,2 20,1 49,0 45,6 42,3 39,0 35,8 32,6 29,4 26,3 1350 2800 tLA °C 16 18 20 22 25 27 29 31 19 21 23 26 28 30 32 34 20 22 25 27 29 31 33 35 26 28 31 33 36 38 40 42 32 35 37 40 42 44 47 49 QO kW 25,3 22,7 20,2 17,6 15,1 12,7 10,2 7,8 27,9 25,2 22,7 20,1 17,6 15,1 12,7 10,2 28,9 26,2 23,7 21,1 18,6 16,1 13,6 11,1 33,9 31,3 28,7 26,1 23,6 21,1 18,6 16,2 38,9 36,2 33,6 31,0 28,5 26,0 23,5 21,0 1000 2000 tLA °C 19 21 23 25 27 29 31 32 23 25 27 29 31 33 34 36 24 26 28 30 32 34 36 37 31 33 35 38 40 41 43 45 38 40 42 44 47 49 51 52 QO kW 36,3 32,6 28,9 25,3 21,7 18,2 14,7 11,2 39,9 36,1 32,5 28,8 25,2 21,7 18,2 14,7 41,5 37,7 34,0 30,4 26,7 23,2 19,6 16,1 48,6 44,9 41,2 37,5 33,9 30,3 26,7 23,2 55,6 51,8 48,1 44,4 40,8 37,2 33,6 30,1 tLA °C 23 24 26 28 29 31 32 33 26 28 30 32 33 35 36 38 28 30 32 34 35 37 38 39 35 37 39 41 43 45 46 48 42 45 47 49 51 52 54 56 QO kW 28,4 25,5 22,7 19,9 17,1 14,4 11,6 8,9 31,1 28,2 25,4 22,6 19,8 17,0 14,3 11,6 32,6 29,7 26,8 24,0 21,2 18,4 15,6 12,9 38,0 35,1 32,3 29,4 26,6 23,9 21,1 18,4 43,3 40,4 37,5 34,7 31,9 29,1 26,4 23,7 max. 0,32 max. 0,32 max. 0,32 max. 0,32 max. 0,62 max. 0,62 max. 0,62 max. 0,62 max. 0,30 - max. 0,30 - max. 0,30 - max. 0,30 - max. 1,40 - max. 1,40 - max. 1,40 - max. 1,40 - 23 16 22,5 15 20 13,5 18 12 4,1 5,5 3,9 5,0 3,6 4,5 5,6 1,0 R ¾“ 1,5 R 1“ 2,0 R 1“ 3,3 2,5 R 1“ * At tLA - tRoom = 10K 7 TopWing Performance table, heating power TLH 63 TLHK 63, Type 4 For warm water Type 1 Speed [min-1] Vol. flow VO [m³/h] PWW 45/35 PWW 50/40 PWW 60/40 PWW 70/50 PWW 80/60 tLE[°C] - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 Motor power [kW] (3 x 400 V) Consumption [A] (3 x 400 V) Motor power [kW] (1 x 230 V) Consumption [A] (1 x 230 V) Throw, wallmounted [m]* Throw, ceilingmounted [m]* Water capacity [L] Connections * At tLA - tRoom = 10K 8 2 900 5300 700 4000 tLA °C 2 5 9 12 16 19 22 26 4 7 11 14 18 21 24 28 4 8 11 15 18 22 25 28 8 11 15 18 22 25 29 32 11 15 18 22 25 29 32 36 QO kW 33,6 30,2 26,7 23,3 20,0 16,7 13,4 10,2 37,1 33,6 30,1 26,7 23,3 20,0 16,7 13,5 38,0 34,6 31,1 27,7 24,3 21,0 17,7 14,4 45,0 41,5 38,0 34,6 31,2 27,8 24,5 21,2 51,9 48,4 44,8 41,4 37,9 34,5 31,2 27,8 tLA °C 4 7 11 14 17 20 23 27 6 9 13 16 19 22 26 29 6 10 13 17 20 23 26 29 10 14 17 21 24 27 30 34 14 18 21 25 28 31 35 38 QO kW 28,6 25,6 22,7 19,8 17,0 14,2 11,5 8,7 31,5 28,5 25,6 22,7 19,8 17,0 14,2 11,5 32,4 29,4 26,5 23,6 20,8 18,0 15,2 12,4 38,3 35,3 32,3 29,4 26,5 23,7 20,9 18,1 44,1 41,0 38,1 35,1 32,2 29,3 26,5 23,7 3 900 5200 700 3900 tLA °C 7 10 13 16 19 22 25 28 10 13 16 19 22 24 27 30 10 13 16 19 22 25 28 31 15 18 21 24 27 30 33 36 19 23 26 29 32 35 38 41 QO kW 43,6 39,1 34,6 30,2 25,8 21,5 17,3 13,1 48,1 43,5 39,0 34,6 30,2 25,9 21,6 17,4 49,3 44,7 40,2 35,8 31,4 27,1 22,8 18,5 58,3 53,7 49,2 44,7 40,3 35,9 31,6 27,3 67,3 62,6 58,0 53,5 49,0 44,6 40,2 35,9 tLA °C 10 13 15 18 21 23 26 29 12 15 18 21 24 26 29 31 13 16 19 22 24 27 30 32 18 21 24 27 30 32 35 38 23 26 29 32 35 38 41 43 QO kW 36,5 32,7 29,0 25,3 21,7 18,1 14,6 11,1 40,2 36,4 32,6 28,9 25,3 21,7 18,1 14,6 41,3 37,5 33,8 30,1 26,5 22,8 19,3 15,7 48,8 45,0 41,2 37,5 33,8 30,2 26,6 23,0 56,2 52,3 48,5 44,7 41,0 37,4 33,7 30,1 4 900 4600 700 3500 tLA °C 14 17 19 22 24 26 28 30 17 20 22 25 27 29 31 33 18 21 23 26 28 30 33 35 24 27 29 32 34 37 39 41 30 33 35 38 40 43 45 48 QO kW 50,7 45,5 40,4 35,3 30,3 25,4 20,5 15,7 55,7 50,5 45,3 40,2 35,2 30,3 25,4 20,6 57,8 52,6 47,4 42,3 37,3 32,3 27,4 22,5 67,9 62,6 57,5 52,3 47,3 42,3 37,3 32,4 77,8 72,5 67,3 62,1 57,0 52,0 47,0 42,1 900 4400 tLA °C 17 19 21 24 26 28 30 31 20 22 25 27 29 31 33 35 22 24 26 28 31 33 34 36 28 30 33 35 37 39 41 43 34 36 39 41 44 46 48 50 QO kW 42,1 37,8 33,6 29,4 25,3 21,2 17,2 13,2 46,2 41,9 37,6 33,5 29,3 25,2 21,2 17,2 48,2 43,9 39,6 35,4 31,2 27,1 23,0 19,0 56,5 52,1 47,8 43,6 39,4 35,3 31,2 27,2 64,5 60,2 55,9 51,6 47,4 43,3 39,2 35,1 700 3400 tLA °C 22 24 26 27 29 31 32 33 25 27 29 31 33 34 36 37 27 29 31 33 35 36 38 39 35 37 39 41 42 44 46 47 41 44 46 48 50 52 53 55 QO kW 61,3 55,1 49,0 42,9 37,0 31,1 25,3 19,5 67,1 60,9 54,8 48,7 42,8 36,9 31,0 25,3 70,5 64,2 58,1 52,0 46,0 40,0 34,1 28,1 82,2 75,9 69,7 63,7 57,6 51,7 45,8 39,9 93,5 87,2 81,1 74,9 68,9 63,0 57,1 51,3 tLA °C 24 26 28 29 31 32 33 34 28 30 32 33 35 36 37 39 30 32 34 36 37 39 40 41 38 40 42 43 45 47 48 49 45 47 49 51 53 54 56 58 QO kW 50,5 45,4 40,4 35,5 30,6 25,8 21,0 16,3 55,2 50,1 45,1 40,1 35,3 30,5 25,7 21,0 58,3 53,2 48,1 43,2 38,2 33,3 28,5 23,6 67,7 62,6 57,6 52,6 47,7 42,8 38,0 33,2 76,9 71,7 66,7 61,7 56,8 52,0 47,1 42,4 max. 0,34 max. 0,34 max. 0,34 max. 0,34 max. 0,85 max. 0,85 max. 0,85 max. 0,85 max. 0,40 - max. 0,40 - max. 0,40 - max. 0,40 - max. 1,80 - max. 1,80 - max. 1,80 - max. 1,80 - 26 18 24 17 21 15 20 14 5,3 6,9 5,1 6,1 4,5 5,8 7,1 2,5 R 1“ 3,5 R 1¼“ 3,5 R 1¼“ 4,4 5,5 R 1¼“ TopWing Performance table, heating power TLH 100 TLHK 100, Type 4 For warm water Type 1 Speed [min-1] Vol. flow VO [m³/h] PWW 45/35 PWW 50/40 PWW 60/40 PWW 70/50 PWW 80/60 tLE[°C] - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 - 15 - 10 - 5 ± 0 + 5 + 10 + 15 + 20 Motor power [kW] (3 x 400 V) Consumption [A] (3 x 400 V) Throw, wallmounted [m]* Throw, ceilingmounted [m]* Water capacity [L] Connections 2 900 9000 700 6700 tLA °C 2 5 9 12 16 19 22 26 4 7 11 14 18 21 24 28 4 8 11 15 18 22 25 28 8 11 15 18 22 25 29 32 11 15 18 22 25 29 32 36 QO kW 57,1 51,2 45,3 39,6 33,9 28,3 22,8 17,3 62,9 57,0 51,1 45,3 39,6 33,9 28,4 22,9 64,6 58,6 52,8 47,0 41,3 35,6 30,1 24,5 76,5 70,5 64,5 58,7 52,9 47,2 41,5 35,9 88,2 82,1 76,1 70,2 64,4 58,6 52,9 47,2 tLA °C 4 7 11 14 17 20 24 27 6 9 13 16 19 22 26 29 7 10 13 17 20 23 26 29 10 14 17 21 24 27 31 34 14 18 21 25 28 31 35 38 QO kW 48,1 43,1 38,2 33,4 28,6 23,9 19,3 14,7 53,0 48,0 43,0 38,2 33,4 28,7 24,0 19,4 54,5 49,5 44,6 39,8 35,0 30,2 25,5 20,9 64,4 59,4 54,4 49,5 44,7 39,9 35,2 30,5 74,2 69,1 64,1 59,1 54,2 49,4 44,6 39,9 3 900 8800 QO kW 72,8 65,2 57,7 50,3 43,0 35,7 28,6 21,6 80,4 72,7 65,1 57,7 50,3 43,0 35,9 28,8 81,9 74,3 66,8 59,3 52,0 44,7 37,5 30,4 97,3 89,5 81,9 74,4 67,0 59,6 52,4 45,2 112,3 104,5 96,8 89,2 81,7 74,3 67,0 59,7 700 6500 tLA °C 7 10 13 16 19 22 25 27 9 12 15 18 21 24 27 30 10 13 16 19 22 25 28 30 14 18 21 24 27 30 33 35 19 22 25 28 32 35 38 40 tLA °C 10 12 15 18 21 23 26 28 12 15 18 21 23 26 29 31 13 16 19 21 24 27 29 32 18 21 24 27 30 32 35 37 23 26 29 32 35 38 40 43 QO kW 60,4 54,1 47,9 41,8 35,7 29,8 23,9 18,1 66,5 60,2 54,0 47,8 41,8 35,8 29,9 24,0 68,2 61,9 55,7 49,5 43,5 37,5 31,5 25,6 80,7 74,3 68,1 61,9 55,7 49,7 43,7 37,8 93,0 86,6 80,2 74,0 67,8 61,7 55,7 49,7 4 900 8300 QO kW 93,9 84,3 74,8 65,5 56,3 47,2 38,2 29,3 103,1 93,4 83,9 74,6 65,3 56,2 47,2 38,2 107,3 97,6 88,1 78,7 69,4 60,2 51,1 42,0 125,9 116,2 106,6 97,1 87,8 78,5 69,4 60,3 144,0 134,3 124,6 115,1 105,7 96,4 87,2 78,2 700 6000 tLA °C 15 17 20 22 24 27 29 31 18 20 23 25 27 30 32 34 19 22 24 27 29 31 33 35 25 28 30 33 35 38 40 42 31 34 36 39 41 44 46 48 QO kW 75,1 67,5 60,0 52,5 45,2 38,0 30,9 23,8 82,3 74,7 67,1 59,7 52,3 45,1 37,9 30,9 86,2 78,5 70,9 63,5 56,1 48,7 41,5 34,2 100,8 93,0 85,4 77,9 70,5 63,2 55,9 48,7 114,9 107,2 99,6 92,0 84,6 77,2 70,0 62,8 900 7700 tLA °C 18 20 23 25 27 28 30 32 21 24 26 28 30 32 34 35 23 25 28 30 32 34 35 37 30 32 34 36 39 41 43 44 36 38 41 43 45 47 49 51 QO kW 107,5 96,8 86,1 75,7 65,4 55,1 45,0 35,0 117,5 106,7 96,1 85,6 75,2 65,0 54,9 44,9 124,4 113,6 102,9 92,3 81,9 71,5 61,2 50,9 144,5 133,6 122,9 112,3 101,9 91,5 81,3 71,1 164,0 153,0 142,3 131,7 121,3 110,9 100,7 90,6 700 5600 tLA °C 22 24 26 28 29 31 32 34 25 27 29 31 33 35 36 38 28 30 32 34 35 37 39 40 35 37 39 41 43 45 46 48 41 44 46 48 50 52 54 55 QO kW 84,5 76,1 67,9 59,7 51,7 43,7 35,8 27,9 92,2 83,8 75,5 67,4 59,3 51,3 43,5 35,7 98,3 89,8 81,5 73,2 65,1 57,0 48,9 40,8 113,7 105,2 96,9 88,6 80,5 72,4 64,5 56,6 128,6 120,1 111,8 103,5 95,4 87,4 79,4 71,6 max. 0,76 max. 0,76 max. 0,76 max. 0,76 max. 1,70 max. 1,70 max. 1,70 max. 1,70 26 18 24 17 21 15 20 14 7,1 5,3 6,9 5,1 6,1 4,5 5,8 4,4 3,5 R 1“ 5,5 R 1½“ 7,5 R 1½“ tLA °C 25 27 28 30 31 33 34 35 29 30 32 34 35 37 38 39 32 33 35 37 38 40 41 42 39 41 43 44 46 48 49 50 46 48 50 52 54 55 57 58 9,5 R 1½“ * At tLA - tRoom = 10K 9 TopWing Dimensions TLH / TLHK Dimensions, basic unit TLH Dimensions, basic unit TLH a TLH 25 40 63 100 a 540 670 840 1040 b 300 300 300 340 c 410 415 420 470 b c Connections, basic unit TLH a c d øe b TLH 25-1 25-2/-3/-4 40-1 40-2/-3/-4 63-1 63-2/-3/-4 100-1 100-2/-3/-4 a 98 158 98 143 103 143 124 179 b 68 68 68 86 63 86 84 89 c 92 95 96 100 95 98 115 109 d Øe 445 ¾“ 445 1“ 574 ¾“ 570 1“ 746 1“ 742 1¼“ 926 1“ 932 1½“ Dimensions, basic unit TLHK Dimensions, basic unit TLHK a TLHK a 25 540 40 670 63 840 100 1040 c d øe 10 d 530 535 540 590 Connections, basic unit TLHK a 1/2” b c 120 120 120 120 c b d 53 b 300 300 300 340 TLHK 25 40 63 100 a 94 99 99 109 b 445 570 743 932 c 68 83 83 89 d 158 143 143 179 Øe 1“ 1“ 1¼“ 1½“ TopWing Shut-off sets / Fixing accessories Shut-off sets for heat exchanger TLH / TLHK Shut-off set as straight-through version or angled version for heat exchanger flow and return for TLH 25: Type 2/3/4, TLH 40: Type 2/3/4, TLH 63: Type 1, TLH 100: Type 1, TLHK 25 and TLHK 40 units are suitable for heating water temperatures up to 110 °C and an operating pressure up to 10 bar. Comprising: 1“ fitting for connection to flow and return with flat gasket Automatic air vent valve (quick-action air vent valve) with automatic shut-off valve in the flow Drain & fill valve with cap and hose connection in the return Ball valves with 1“ female thread in the flow and return Durchgangsform Eckform Connection option ¾“ male thread (e.g. for thermometer) in the flow and return Hydraulic balancing valves to ensure even heat distribution in the system Hydraulic balancing valve Brackets DN 20 DN 20 DN 25 4 - 15 l/min 8 - 30 l/min 6 - 20 l/min DN 25 DN 32 DN 40 10 - 40 l/min 20 - 70 l/min 30 - 120 l/min For wall- and ceiling-mounting, made of folded sheet steel, 2mm thick, powder-coated, colour standard white RAL 9016. Complete installation kit, consisting of: 2 brackets and hex-head screws for installation in the TLH/TLHK heater TLH/TLHK a b c d e f g h i 25 40 63 100 480 480 784 784 250 250 350 350 380 2x170 170+340+170 170+340+170 70 90 72 72 30 50 32 32 170 2x170 3x170 3x170 155 70 137 137 155 70 137 137 434 564 734 894 11 TopWing Fixing accessories Fixing set for concrete beam, vertical For fixing the TLH/TLHK to a concrete beam by hooking it into a pre-assembled installation rail. Provide rawl plugs and screws on site. Comprising: Installation rail, 2 mounting rails (zinc-plated sheet steel), screws and nuts. Mounting rail Fixing set for steel beam, vertical TLH/TLHK 25 40 b 100-300 100-300 25 40 b 100-300 100-300 Support rails Mounting brackets TLH-appliance For fixing to a steel beam by hooking into a pre-assembled installation rail using clamping claws. Suitable for all steel beams with a flange width “b” of 100 mm to 300 mm, and a flange thickness “t“ of 6 mm to 21 mm. Comprising: Installation rail, 2 mounting rails (zinc-plated sheet steel), 4 clamping claws, screws and nuts. t 6-21 6-21 Fixing set for horizontal and tilted steel beams, with no selfaligning brackets TLH TLH / TLHK For fixing to a horizontal or tilted steel beam with a flange width “b“ of 100 mm to 300 mm, and a flange thickness “t“ of 6 mm to 21 mm. Comprising: 2 mounting rails (zinc-plated sheet steel), 4 clamping claws, screws and nuts. * Provide M8 threaded rods on site. Installation examples: t 6-21 6-21 * Fixing directly to a horizontal steel beam Note: 12 Fixing directly to a tilted steel beam Suspended fixing to a horizontal steel beam Before using the fixing sets, check and factor in the static regulations of the on-site concrete pillars or steel beams. TopWing Fixing accessories Fixing set for tilted steel beam with self-aligning brackets TLH / TLHK For fixing to a steel beam with a flange width “b“ of 100 mm to 300 mm, and a flange thickness “t“ of 6 mm to 21 mm. Comprising: 2 mounting rails (zinc-plated sheet steel), 4 clamping claws, 4 self-aligning brackets, screws and nuts. Mounting rail Clamping claw M8 threaded rods (on site) Fixing panels Self-aligning bracket TLH unit TLH 25 40 Hangers for configurations with horizontal air flow b 100-300 100-300 t 6-21 6-21 For suspending the TLH/TLHK heater vertically from the ceiling, powder-coated, color standard white RAL 9016. Suitable for use in conjunction with threaded rods or perforated strip for configurations with horizontal air flow. (Set = 4 pce) TLH/TLHK 25 40 63 100 a 350 480 650 810 b 266 266 266 306 c 60 60 60 60 13 TopWing Fixing accessories Hangers for configurations with vertical air flow TLH / TLHK For suspending the TLH heater horizontally from the ceiling, powder-coated, color standard white RAL 9016. Suitable for use in conjunction with threaded rods or perforated strip for configurations with vertical air flow. (Set = 4 pce) Outermost anchorange on rear panel TLH 25 40 63 100 Bracket for intake accessory, loose b 580 710 880 1040 c 620 750 920 1080 dmin 250 250 350 350 For wall-mount or ceiling-mount installation of the TLH heater and zur for wall-mount of the TLHK heater with mixed-air box, recirculated-air box, outdoor-air box or filter box, powder-coated, color standard white RAL 9016. Four brackets are required for installation and are enclosed with the intake accessory (seal against wall/ceiling to be provided by others). TLH/TLHK 25 40 63 100 14 a 270 440 610 780 a 500 630 800 1000 b 550 680 850 1050 c 600 730 900 1100 TopWing Discharge Accessories Discharge cone TLH To increase throw if the unit is high above the floor. Powder-coated, color standard white RAL 9016. (See pages 35/36 for throw) TLH 25 40 63 100 Discharge nozzle a 460 590 760 920 b 420 550 720 880 c 190 250 260 320 d 390 480 585 685 c 200 240 270 320 d 750 790 920 1010 e 940 1030 1235 1375 With adjustable deflector vanes, suitable for heating low-ceilinged rooms, uniform air discharge to all four sides. Powder-coated, color standard white RAL 9016. Vanes Wolf silver, similar to RAL 9006. TLH 25 40 63 100 Wide discharge / swirl wide discharge b 460 590 760 920 For extended throw, suitable as an air curtain at doors. Discharge temperature for air-curtain operation approx. 10-15°C above room temperature. Powder-coated, color standard white RAL 9016. (See pages 40/41 for throw) TLH 25 40 63 100 Four-way discharge a 280 370 430 530 a 500 630 800 1000 b 155 155 155 155 c 705 705 805 845 Spread the stream of warm air to each side. Air cone spread up to approx. 120°; vanes individually adjustable horizontally and vertically. Powder-coated, color Wolf silver, similar to RAL 9006. Wide discharge Swirl wide discharge (See pages 40/41 for throw) 15 TopWing Discharge Accessories Induction louver with secondary-air cone TLH For optimizing throw and temperature distribution Description of function The induction louver with secondary-air cone divides the warm air into separate flows and inducts secondary air (room air) directly into the current of warm air downstream from the deflector vanes. The induction of secondary air ensures that the warm air is thoroughly mixed with the room air within a very short distance, and this reduces the discharge temperature of the air. This reduction in temperature prevents the warm air from rising, thus extending throw and depth of penetration into the room, especially in systems with high air-discharge temperatures. The induction louver with secondary-air cone is adjustable (which means that the direction of the current of warm air is also variable) and can be moved either manually or by means of an electric motor to suit all operating conditions and on-site situations. Wall-mounted Energy savings High temperatures close to the ceiling are avoided, and this reduces ventilation-related and transmissionrelated heat losses. Energy savings up to 15% can be achieved. Scope of supply Induction louver with secondary-air cone mounted on the heater, with 230V / 50Hz servomotor for control via pushbutton, or servomotor 24 V which can be controlled via ventilation module LM2. Alternatively: Induction louver with secondary-air cone, manually adjustable. Ceiling-mounted Dimensions of basic unit and induction louver with secondaryair cone a TLH 25 40 63 100 b d 16 c a 540 670 840 1040 b 300 300 300 340 c 120 120 120 120 d 530 535 540 590 TopWing Intake Accessories Mixed-air box optional: with or without thermal isulation For custom air-flow settings. Outdoor-air intake at the rear, recirculated-air intake at the side or from above or below with the mixed-air box turned through 90°. Powder-coated, color standard white RAL 9016. Stepless adjustment between recirculated air only through mixed air to outdoorair only, adjustment manual or by means of 230V servomotor. In Connection with LM2 ventilation control unit 24V stepless. TLH/TLHK 25 40 63 100 Recirculated-air box TLH/TLHK 25 40 63 100 a 500 630 800 1000 b 300 500 500 540 a 500 630 800 1000 b 300 500 500 540 a 400 530 700 860 b 500 500 500 540 c 800 800 800 880 d 245 360 530 690 e 400 530 700 860 c 600 600 600 680 Outdoor-air box with air intake at rear, for connection to a wall penetration or outdoor-air duct. Powdercoated, color standard white RAL 9016. c 600 800 800 880 Louver flap for outdoor-air box TLH 25 40 63 100 a 500 630 800 1000 Recirculated-air box for recirculated-air intake through two side screens or, when rotated through 90°, intake from above and below. Powder-coated, color standard white RAL 9016. Outdoor-air box TLH 25 40 63 100 TLH / TLHK Louver flap for installation in outdoor-air box, sheet steel, galvanized. For damper actuators, see page 22-23. b 400 530 700 860 17 TopWing Intake Accessories Filter box TLH/TLHK 25 40 63 100 a 500 630 800 1000 With filter element as dust trap in outdoor-air and mixed-air modes, filter category G4 for TLH-(K) 63, filter category G3 for TLH-(K) 25, 40, 100. Bracket on request. Powder-coated, color standard white RAL 9016. b 300 300 300 340 c 600 600 600 680 Rain cowl with birdproof screen TLH/TLHK 25 40 63 100 a 640 770 940 1140 TLH / TLHK b 500 630 800 1000 Roof penetration With birdproof screen (flow-stop louver available on request), for inducting outdoor air through the roof. Connects to TLH/TLHK heater with roof penetration. Sheet steel, galvanized. c 606 736 906 1106 d 1011 1254 1570 1944 For connecting the TLH/TLHK heater to the rain cowl through the roof. Roof must be sealed on site. Sheet steel, galvanized. TLH/TLHK 25 40 63 100 Flashing b 500 630 800 1000 c 600 730 900 1100 As weathering collar for roof penetration, sheet steel, galvanized TLH/TLHK 25 40 63 100 18 a 1100 1100 1100 1100 a 170 170 170 170 b 580 710 880 1080 TopWing Intake Accessories Intake cowl with weatherproof screen With birdproof screen for outdoor-air intake through the wall (available with flow-stop louver on request). Sheet steel, galvanized. TLH/TLHK 25 40 63 100 Flow-stop louver for rain cowl/intake cowl TLH / TLHK a 470 600 770 960 b 480 610 780 960 c 330 420 545 680 d 320 380 550 710 e 420 550 720 880 For installation in the rain cowl or in the wall penetration for the intake cowl. Sheet steel, galvanized. TLH/TLHK 25 40 63 100 Weatherproof screen a 360 420 590 750 c 460 590 760 920 d 400 530 700 860 Weatherproof screen with birdproof screen. Sheet steel, galvanized. TLH/TLHK 25 40 63 100 Weatherproof screen with flow-stop louver b 300 360 530 690 a 410 540 710 870 b 75 55 55 50 c 20 20 20 20 Weatherproof screen with birdproof screen and flow-stop louver. Sheet steel, galvanized. TLH/TLHK 25 40 63 100 a 410 540 710 870 b 75 55 55 50 c 20 20 20 20 19 TopWing Switchgear and Control Units TLH Single-phase AC motor 230 V Three-phase motor 3 x 400 V 5x 5x 6x 6x 9x E5-7T 5-stage 6x E3-7T 3-stage D5-... 5-stage D3-4 3-stage DS-2 2-stage D1-2 1-stage 5x 5x 3x Thermostatic timer with day/week programs 4x Thermostatic timer with week programs and remote temperature sensor 4x Room thermostat, industrial grade Room thermostat with summer / winter switch Room thermostat 20 TopWing SwitchgearTLH D1-2 1-stage switch D1-2 Supply Fan motor with thermo contact L1 L2 L3 N PE 200 For single-speed operation of one or more unit heaters with thermistor-type motor protection and restart disablement. L1 150 Operating voltage 400 V Control voltage 230 V Capacity, max. 8A Weight 0,9 kg Degree of protection IP 54 L2 L3 PE N TK T W2 U2 V2 T U1 V1 W1 U1 V1 W1 TK PE Bridge acc. To type plate. R2 * R1 150 1 F1 J 3 13 53 5 A1 K1 2,5AT 2 H2 4 A2 14 54 6 H1 1µF X2 250V 0 1 S1 3 4 1 2 * When connecting a room thermostat remove bridge. H1 - Operation (green),H2 -Break-down (red) S1/K1 - Contact location depends on the type installed by factory T- TB/TW Thermo contact Contact K1 53-54 Heater requirement Automatic restart when winding temperature drops (motor). Restart by setting multistage switch to 0 position and then select desired speed. DS-2 2-stage switch DS-2 Supply L1 L2 L3 N PE 200 For two-speed operation of one or more unit heaters with thermistor-type motor protection and restart disablement. Fan motor with thermo contact L1 150 Operating voltage 230 V Capacity, max. 8A Weight 0,9 kg Degree of protection IP 54 L3 PE N T TK TK PE W2 U2 V2 U1 V1 W1 U1 V1 W1 W2 U2 V2 R2 * R1 150 1 400 V Control voltage L2 T J H2 1µF X2 250V S1 3 5 13 53 A1 K1 F1 2,5AT 2 4 6 14 54 A2 H1 0 1 2 18 17 2 9 13 3 6 14 15 8 10 Automatic restart when winding temperature drops (motor). Restart by setting multistage switch to 0 position and then select desired speed. Note: * When connecting a room thermostat remove bridge. H1 - Operation (green),H2 -Break-down (red) S1/K1 - Contact location depends on the type installed by factory T- TB/TW Thermo contact F2-4 5,0AT Contact K1 53-54 Heater requirement Without switches for complete protection we do not give motor warranty! When the winding temperature is being exceeded without a complete motor protection switch, the motor can get badly damaged. Thermistor-type motor protection switches for 3 x 230 V available on request. 21 TopWing SwitchgearTLH D3-4 3-stage switch D 3-4 with restart disablement Supply Fan motor with thermo contact L1 L2 L3 N PE For 3-speed operation of one or more unit heaters with thermistor-type motor protection. L1 Operating voltage 400 V Control voltage 230 V Current, max. 8,0 kg Degree of protection IP 20 L3 PE N TK W2 U2 V2 T U1 V1 W1 U1 V1 W1 TK PE * R2 R1 3 4 F1 ϑ 2,5AT F2 H2 1µF X2 250V 4A Weight L2 Bridge acc. To type plate. T F3 F4 H1 0 3 2 1 1 3 5 13 3 2 4 6 14 4 A1 K1 A2 13(23) 14(24) 5 (9) 3 (5) 1 (1) 4 (4) 3 2 1 10 (16) 9 (13) 11(17) 7 (21) 400V 230V 140V 140V 230V 400V 1 2 3 T1 T2 * When connecting a room thermostat remove bridge. H1 - Operation (green),H2 -Break-down (red) S1/K1 - Contact location depends on the type installed by factory T- TB/TW Thermo contact Contact 3/4 -Heater requirement F2-4 = D5-1 – 1,25AT (6,3x32mm) Latched shutdown if winding overheats (motor). Restart by setting multistage switch to 0 position and then select desired speed. D5-1 5-stage switch D 5... Fan motor with thermo contact Supply L1 L2 L3 N PE For 5-speed operation of one or more unit heaters with thermistor-type motor protection with restart disablement. PE N L1 L2 L3 TK T W2 U2 V2 T U1 V1 W1 U1 V1 W1 TK PE Bridge acc. To type plate. R2 * R1 3 4 F2-4 Dimensions D5-1 D5-3 D5-7 D5-12 D5-19 Width A 150 230 230 230 310 Height B 200 310 310 310 385 Depth C 175 185 185 185 225 D5-1 D5-3 D5-7 D5-12 D5-19 Type Operating voltage V 400 400 400 400 400 Control voltage V 230 230 230 230 230 1 2 4 7 12 kg 4,5 7,0 9,0 19,0 27,0 Protection IP 40 20 20 20 20 Current, max. A Note: 1µF X2 250V S1 3 5 13 53 A1 K1 2,5AT 2 H2 Type Weight 1 F1 ϑ 4 6 14 54 A2 H1 0 5 4 3 2 1 21 (23) 22 (24) 7 3 9 5 1 4 (7) (3) (9) (5) (1) (4) 20 (16) 13 (13) 17 (17) 11 (21) 15 (15) 19 (19) 5 4 3 2 1 1 2 3 4 5 400V 280V 230V 180V 140V T1 140V 180V 230V 280V 400V T2 * When connecting a room thermostat remove bridge. H1 - Operation (green),H2 -Break-down (red) S1/K1 - Contact location depends on the type installed by factory T- TB/TW Thermo contact Contact 3/4 -Heater requirement F2-4 = D5-1 – 1,25AT (6,3x32mm) Latched shutdown if winding overheats (motor). Restart by setting multistage switch to 0 position and then select desired speed. Without switches for complete protection we do not give motor warranty! When the winding temperature is being exceeded without a complete motor protection switch, the motor can get badly damaged. Thermistor-type motor protection switches for 3 x 230 V available on request. 22 TopWing SwitchgearTLH E3-7T 3-stage switch E 3-7T with restart disablement Supply 200 For 3-speed operation of one or more unit heaters with single-phase AC motors with thermistor-type motor protection. L1 N PE 150 Fan motor with thermo contact 150 PE L1 N T T Z U2 U1 PE TK TK PE N VM R1 * R2 3 4 F2 1 Operating voltage Current, max. 3 230 V 4,5 kg Degree of protection IP 40 A1 K1 2,5AT 2 6 4 7A Weight 7 5 F1 8 A2 1µF X2 250V H1 ϑ H2 S1 0 3 2 1 7 ( 11 ) 8 ( 12 ) 3 2 1 0 5 (5) 3 (3) 1 (1) 6 ( 10 ) T1 230V 145V 105V * When connecting a room thermostat remove bridge. H1 - Operation (green),H2 -Break-down (red) S1/K1 - Contact location depends on the type installed by factory T- TB/TW Thermo contact Contact 3/4 -Heater requirement F2 – 8,0AT ( 6,3x32mm ) Latched shutdown if win ding overheats (motor). Restart by setting multistage switch to 0 position and then select desired speed. E5-7T 5-stage switch E 5-7T with restart disablement Supply 200 For 5-speed operation of one or more unit heaters with single-phase AC motors wit thermistor-type motor protection and restart disablement. L1 N PE Fan motor with thermo contact T 17 5 PE 150 F2 8AT Operating voltage Current, max. 230 V N TK TK 1 3 5 4,5 kg Degree of protection IP 40 13 Z N VM U2 R1 U1 PE * R2 3 4 A1 K1 2,5AT 2 14 6 4 1µF X2 250V A2 H1 H2 S1 0 5 4 3 2 1 1 ( 11 ) 2 ( 12 ) 11 ( 9 ) 9 (7) 7 (5) 5 (3) 3 (1) 4 ( 10 ) Automatic restart when winding temperature drops (motor). Restart by setting multistage switch to 0 position and then select desired speed. PE F1 7A Weight Note: L1 T 5 4 3 2 1 0 T1 230V 160V 145V 130V 105V * When connecting a room thermostat remove bridge. H1 - Operation (green),H2 -Break-down (red) S1/K1 - Contact location depends on the type installed by factory T- TB/TW Thermo contact Contact 3/4 -Heater requirement Without switches for complete protection we do not give motor warranty! When the winding temperature is being exceeded without a complete motor protection switch, the motor can get badly damaged. Thermistor-type motor protection switches for 3 x 230 V available on request. 23 TopWing Switchgear Switch for 230V / 50Hz servomotor, induction louver with secondary-air cone TLH / TLHK L N PE For surface mounting or flush mounting; for stepless adjustment of the induction louver for optimized throw.. Operating voltage 230 V Current, max. 10 A Degree of protection IP 20 Surface-mount/ flushmount switch 1 Zu Auxiliary terminal by others 2 close open 1 2 3 N Zu Auf LM 230 W 24 1 4 2 5 Auf Servomotor open/close 230V induction louver TopWing SwitchgearTLH Automatic relay, A1 Auxiliary relay for automatic actuation of the outdoor-air flap with 230 V servomotor for „open/ close“. Open/close servomotor 2 3 1 When the TLH switches off or the frost-protection thermostat trips, the A1 automatic relay moves the servomotor to the „closed“ position. When the TLH switches on the A1 moves the servomotor to the „open“ position. Control voltage 230 V Capacity, max. 1,5 kW Weight 0,5 kg Degree of protection IP 54 Interchange 2 and 3 to reverse function M 8 9 4 3 11 1 Automatic relay A1 Frostprotection thermostat J 10 K1 2 AL UL F1 3,15A Outdoor/ recirculated air switch (by others) L1 N PE 1 Switchgear Open/close servomotor M interchange 2 and 3 to reverse function 2 3 A1 K1 A2 8 9 4 3 11 1 10 K2 2 Automatic relay A1 F1 3,15A L1 L2 L3 N PE Automatic relay, A1S Auxiliary relay with integral position controller for automatic actuation of the mixed-air flap with 230 V servomotor for stepless positioning. Servomotor, stepless The automatic relay A1S switches the actuator to the position set on the position transmitter, if the LH-unit is switched off or if the anti-frost thermostat is activated. Switching on the LH-unit, the actuator switches to the position set at the position transmitter. Control voltage 230 V Capacity, max. 1,5 kW Weight 0,5 kg Degree of protection IP 54 Position controller Switchgear 25 TopWing SwitchgearTLH Servomotor stepless, for outdoor-air/recirculated-air flap Servomotor OPEN/CLOSED for outdoor-air flap A1 automatic relay Automatic relay A1S with integral position controller A1 automatic relay Position controller Frostprotection thermostat Switchgear or control unit Servomotor, OPEN/CLOSE 230V Motor drive for an outdoor-air flap in conjunction with an A1 automatic relay. TLH starts up TLH shuts down or frost-protection device trips Servomotor, stepless 230V or 24V 26 Outdoor-air flap opens Outdoor-air flap opens Stepless, motor-driven actuation of outdoor-air and recirculated-air flaps in conjunction with an A1 automatic relay and a position controller, either in the switchgear cabinet or surface-mounted, or with an A1S automatic relay with integral position controller TLH starts up Outdoor-air flap opens to preset distance, recirculated-air flap closes accordingly.nd. TLH shuts down or frost-prorection device trips Outdoor-air flap closes fully recirculating-air flap opens 100%. TopWing Room Thermostats TLH Room Thermostat Plastic housing 75 x 75 x 25 mm for surface mounting. Switching capacity: heating 10(4) A, cooling 5(2) A at 230 V / 50 Hz, thermal feedback. Temperature range 5 - 30 °C Switching differential 0,5 K Degree of protection IP 30 Room thermostat with summer/winter switch Plastic housing 75 x 75 x 25 mm for surface mounting. Switching capacity: heating 10(4) A, cooling 5(2) A at 230 V / 50 Hz, thermal feedback. Temperature range 5 - 30 °C Switching differential 0,5 K Degree of protection IP 30 Room thermostat, industrial grade Plastic housing 150 x 110 x 72 mm for surface mounting. Switching capacity 16(4) A at 230 V / 50 Hz Temperature range 0 - 40 °C Switching differential ±0,75 K Degree of protection IP 54 Thermostatic timer with week program Plastic housing 132 x 82 x 32 mm for installation in plug-in base; day and night temperatures can be adjusted separately. Temperature setback can be adjusted by 2 - 10 K Switching capacity 10(4) A at 230 V / 50 Hz Temperature range 5 - 40 °C Switching differential can be adjusted by ±0,1 - 3 K Degree of protection IP 20 External remote sensor (optional) 27 TopWing Thermostats, terminal box Remote sensor for room thermostat clock TLH Plastic housing 52 x 50 x 35 mm for installation in plugin base. Degree of protection IP 54 Frost-protection thermostat If the air discharge temperature drops below a preset value the frost-protection thermostat switches off the TLH to prevent frost damage to the heat exchanger. The TLH restarts automatically when the air discharge temperature increases. The frost-protection thermostat must be wired in series with the thermal contacts! Switching capacity 10 A at 230 V / 50 Hz Range of adjustment 2 °C to 20 °C Switching differential 2,5 K Degree of protection IP 43 Dimensions W x H x D Intermediate terminal box 85 x 75 x 40 mm Intermediate terminal box for parallel wiring of up to three TLH heaters with 3 x 400V, 50Hz motors. Degree of protection IP 54 Dimensions W x H x D 105 x 170 x 112 mm All-pole Isolator AR8 28 fitted and wired TopWing Control systems for TLH BML ventilation programming module • • • • • • • • WRS Room-/weather-compensated temperature control LCD with background illumination Easy plain text guide through the menus Control by rotary selector with key function Four function keys for frequently used functions (Info, Temperature- , speed adjustment, fresh air proportion) Installation either inside the ventilation control unit or, as remote control, in a wall mounting base Only one BML ventilation programming modul required to control up to 7 zones Demand-optimised boiler water temperature demand via eBUS eBus interface Wall mounting base • Wall mounting base for use with the BML ventilation programming module as remote control. LM1 ventilation control unit • • • • • LM2 ventilation control unit • Ventilation module LM2 to control the room temperature via speed or mixer • 2-stage motor control in conjunction with ventilation module LM1 or 5-stage motor control via 0-10V signal in connection with 5-stage switch • Easy controller configuration by selecting one of the preset system versions • Control of one heat source Demand-optimised boiler water temperature demand via eBUS • eBus interface with automatic energy management • BML ventilation programming module to clip into LM2 ventilation control unit • Control of mixed air damper (in connection with servomotor 24V) • Induction louvre control (incl. room temperature sensor) Ventilation module to control air heaters with a two-stage motor Easy controller configuration by selecting one of the preset system versions Demand-optimised room temperature control via air heater speed Control of the heating circuit pump Control of one heat source Demand-optimised boiler water temperature demand via eBUS eBus interface with automatic energy management BML ventilation programming module to clip into LM2 ventilation control unit Outside-, ceiling- or room temperature sensor Radio clock • For synchronising the clock inside the control unit with the DC77 transmitter Radio clock with outside temperature sensor • For synchronising the clock inside the control unit with the DC77 transmitter, and capturing the outside temperature 29 TopWing Control systems for TLH Differential pressure switch • Differential pressure switch, loose, for on-site control. 5-stage switch 0-10 V • Electronic five-stage speed controller, input 0-10V Supply air sensor and sensor retainer • for measuring the supply air temperature ISM 5 - LON-interface module • to connect ventilation modules LM1 and LM2 to a building management system applying LON-standard network variables 30 WRS TopWing Control systems for TLH WRS LM1 ventilation control unit with BML Description This configuration is used for heating buildings in conjunction with air heaters. The room temperature is captured by a sensor and the fan, heating circuit pump and heat source are switched on or off subject to demand. If the temperature deviation (set room temperature to actual room temperature) is low, the fan is operated in stage 1. If the temperature deviation is greater, it is switched to stage 2. AF Example: Unit heater, heating with room temperature control 2 BML 2 LM1 2 5 9 2 3 L1 L2 L3 N PE J supply Heating circuit pump room sensor Unit heater Boiler Installation diagram: BML LM1/X1 X1/K1 X1/eBus Netz X1/M2 B1 X1/B2 2 X1/M1 X1/B3 6 4 5 Nr. Description 1 room sensor 2 outside sensor 3 external release 4 motor 2-stage 5 heating circuit pump 6 heat source 3 1 31 TopWing Control systems for TLH WRS LM1 ventilation control and LM2 with BML Description: This configuration is used for heating buildings in conjunction with air heaters. The room temperature is captured by a sensor, and the fans, heating circuit pump, heating circuit mixer and heat source are switched on or off subject to demand. Example: Unit heater, heating with room temperature control, Mmixer control, motor control, 2-stage 2 BML AF 2 2 2 LM1 LM2 5 3 3 2 9 3 3 J 2 3 L1 N PE HCP mixer LD15 supply M Unit heater 2 J supply L1 L2 L3 N PE 2 2 3 mixed air J frost-protection thermostat supply room air sensor M sensor J ceiling induction sensor louver Boiler Installation diagram: BML LM1/X1 LM1/X2 LM2/X2 LM2/X1 Netz X2/M1 Netz SS 14 X1/B2 3 X2/B3 X2/M2 B1 X1/B1 X1/B5 4 32 Nr. Description 1 room sensor 2 supply air sensor 3 outside sensor 4 ceiling sensor 5 External release 7 Frost-protection thermostat 8 induction louver 9 motor 2-stage 10 heating circuit pump 11 heating circuit mixer 12 heat source 13 mixed air damper 14 LD15, ceiling fan X1/Y3 X1/Y2 M1 X1/K1 5 X1/B4 8 2 13 7 eBus 9 X1/Y1 X1/M2 1 11 10 12 TopWing Control systems for TLH WRS LM2 ventilation control unit with BML Description: This configuration is used for heating buildings in conjunction with air heaters. The room temperature is captured by a sensor, and the fans, heating circuit pump, heating circuit mixer and heat source are switched on or off subject to demand. The extract air fan is enabled subject to the fresh air proportion. Example: Unit Heater, heating with room temperature control, mixer control, motor control with electronic 5-stage speed regulator AF 2 BML 2 Electronic 5-stage control unit 2 2 Electronic 5-stage control unit LM2 2 0 - 10V 0 - 10V 5 2 3 5 3 2 3 3 J 2 3 L1 N PE 9 L1 L2 L3 N PE supply 9 HcP mixer L1 L2 L3 N PE Extract air unit M supply Mixed air unit 2 J supply mixed air 2 M induction louver supply air sensor J Room sensor Frostprotection thermostat J ceiling sensor Boiler Installation diagram: Nr. Description 1 room sensor 2 supply air sensor 3 outside sensor 4 ceiling sensor 5 mixed air damper 6 fan 7 frequency inverter 8 heating circuit pump 9 heating circuit mixer 10 heat source 11 frost-protection thermostat 12 induction louver 33 TopWing 5-stage electronic switch 0 - 10V TLH / TLHK 5-stage switch 0-10 V: Switch type D5-2F D5-4F E5-6F Voltage 400 V 400 V 230 V 2A 4A 6A Weight 7,4 kg 11,0 kg 5,2 kg Degree of protection IP 21 IP 21 IP 20 Capacity, max. L=170 B=220 H=315 Wiring diagram D5-..... 1 2 3 4 5 D1 D1 TB TB 13 14 15 16 6 * fault indication T2 of LM2 N L1 L2 L3 N L1 L2 L3 PE V U Operation indication supply 3~400V U ON/OFF 01 TB TB * If the function is not required, bridge the terminals fault indication supply 1~230V Operation indication ON/OFF * If the function is not required, bridge the terminals 34 V M 3~ W PE bzw. 3~ motor with integral thermostat switches Wiring diagram E5-6F T2 of LM2 (0 - 10 V) W * TopWing Room Thermostats Room Thermostat TLHK Plastic housing 75 x 75 x 25 mm for surface mounting. Switching capacity: heating 10(4) A, cooling 5(2) A at 230 V / 50 Hz, thermal feedback. Temperature range 5 - 30 °C Switching differential 0,5 K Degree of protection IP 30 Room thermostat with summer/winter switch Plastic housing 75 x 75 x 25 mm for surface mounting. Switching capacity: heating 10(4) A, cooling 5(2) A at 230 V / 50 Hz, thermal feedback. Temperature range 5 - 30 °C Switching differential 0,5 K Degree of protection IP 30 Room thermostat, industrial grade Plastic housing 150 x 110 x 72 mm for surface mounting. Switching capacity 16(4) A at 230 V / 50 Hz Temperature range 0 - 40 °C Switching differential ±0,75 K Degree of protection IP 54 Thermostatic timer with week program Plastic housing 132 x 82 x 32 mm for installation in plug-in base; day and night temperatures can be adjusted separately. Temperature setback can be adjusted by 2 - 10 K External remote sensor (optional) Switching capacity 10(4) A at 230 V / 50 Hz Temperature range 5 - 40 °C Switching differential can be adjusted by ±0,1 - 3 K Degree of protection IP 20 35 TopWing Thermostats, terminal box Remote sensor for room thermostat clock TLHK Plastic housing 52 x 50 x 35 mm for installation in plugin base. Degree of protection IP 54 Frost-protection thermostat If the air discharge temperature drops below a preset value the frost-protection thermostat switches off the TLHK to prevent frost damage to the heat exchanger. The TLHK restarts automatically when the air discharge temperature increases. The frost-protection thermostat must be wired in series with the thermal contacts! Switching capacity 10 A at 230 V / 50 Hz Range of adjustment 2 °C to 20 °C Switching differential 2,5 K Degree of protection IP 43 Dimensions W x H x D Intermediate terminal box 85 x 75 x 40 mm Intermediate terminal box for parallel wiring of up to three TLHK heaters with 3 x 400V, 50Hz motors. Degree of protection IP 54 Dimensions W x H x D 105 x 170 x 112 mm All-pole Isolator AR8 36 fitted and wired TopWing Control systems for TLHK BML ventilation programming module • • • • • • • • WRS Room-/weather-compensated temperature control LCD with background illumination Easy plain text guide through the menus Control by rotary selector with key function Four function keys for frequently used functions (Info, Temperature- , speed adjustment, fresh air proportion) Installation either inside the ventilation control unit or, as remote control, in a wall mounting base Only one BML ventilation programming modul required to control up to 7 zones Demand-optimised boiler water temperature demand via eBUS eBus interface Wall mounting base • Wall mounting base for use with the BML ventilation programming module as remote control. LM1 ventilation control unit • • • • • LM2 ventilation control unit • Ventilation module LM2 to control the room temperature via speed or mixer • 2-stage motor control in conjunction with ventilation module LM1 or 5-stage motor control via 0-10V signal in connection with 5-stage switch • Easy controller configuration by selecting one of the preset system versions • Control of one heat source Demand-optimised boiler water temperature demand via eBUS • eBus interface with automatic energy management • BML ventilation programming module to clip into LM2 ventilation control unit • Control of mixed air damper (in connection with servomotor 24V) • Induction louvre control (incl. room temperature sensor) Ventilation module to control air heaters with a two-stage motor Easy controller configuration by selecting one of the preset system versions Demand-optimised room temperature control via air heater speed Control of the heating circuit pump Control of one heat source Demand-optimised boiler water temperature demand via eBUS eBus interface with automatic energy management BML ventilation programming module to clip into LM2 ventilation control unit Outside-, ceiling- or room temperature sensor Radio clock • For synchronising the clock inside the control unit with the DC77 transmitter Radio clock with outside temperature sensor • For synchronising the clock inside the control unit with the DC77 transmitter, and capturing the outside temperature 37 TopWing Control systems for TLHK Differential pressure switch • Differential pressure switch, loose, for on-site control. 5-stage switch 0-10 V • Electronic five-stage speed controller, input 0-10V Supply air sensor and sensor retainer • for measuring the supply air temperature ISM 5 - LON-interface module • to connect ventilation modules LM1 and LM2 to a building management system applying LON-standard network variables 38 WRS TopWing Planning information General guidelines TLH, wall-mounted Position Wolf unit heaters in such a way and brackets that the discharged air does not blow directly on to people or machines. TLH, ceiling-mounted and brackets TLH / TLHK TLHK, wall-mounted and brackets Temperature distribution in a room is more uniform if a number of small units are installed instead of one large unit. Whenever possible the heaters should be arranged in such a way that their discharge currents support the circulation of the air in the with filter box, Mixed-air box and with discharge nozzle and brackets with filter box, Mixed-air box and Weatherproof screen room, rather than blowing in opposed Weatherproof screen directions. An unobstructed intake of air must be ensured at all times. Select the throw of your Wolf heaters to suit the dimensions of the room. The figures in the performance tables are guideline values that can be varied by installing accessories such as discharge cones, wide discharges and four-way discharges to suit the dimensions of individual rooms. (accessories for TLH only). The sound levels of Wolf unit heaters are very low. The dB(A) values quoted in the performance tables are averages. with discharge nozzle and brackets All control and shutoff valves must close automatically when the fan shuts down. General notes on planning Wide discharge/ swirl wide discharge to shorten throw and widen the current of air Installation height min. 2,5m max. 4,0m min. 0,7m TLH / TLHK: • The requisite air volume flow rate (m³/h) is at least 2.5 or better 3-4 times the enclosed space. • Make sure the current of air does not blow directly on to persons in the room. • Spacing between heaters 10-15m. • Wall-mounted heaters: distance above floor min 2.5m, max. 4m. • Take the throw into account. • Install wall-mounted heaters at the heights indicated in the sketch on the left. TLH: • If distanace between heater and opposite wall is short, install a wide discharge or a swirl-wide discharge. • If the throw of a ceiling-mounted heater with discharge louver is insufficient, install a discharge cone or an induction louver with secondary-air cone. • In low-ceilinged rooms where the distance from the bottom of the discharge screen to the floor is less than 2.5m, use a four-way discharge. 39 TopWing Planning information TLH Clearances Secondary eddy 40 9 - 11 3-5 63 11 - 13 4-6 100 13 - 15 5-7 Primary air by approx. 25% 3-4 Throw increased TLH to wall 7-9 min. 2,0 m TLH to TLH 25 up to max. 2,5 m TLH Throw Clearances for ceiling-mounted or wallmounted TLH heaters in m Secondary eddy Primary air Primary air Spacing Spacing Spacing 7 - 15 m 7 - 15 m 3-7m Discharge cone to increase throw in high-ceilinged rooms Four-way discharge for low-ceilinged rooms Discharge accessories for optimized air distribution For clearances as specified above, air-temperature increase ∆tL ( = tdischarge - troom ) of approx. 25K and high speed TLH Clearance: discharge/floor up to 2,5 m 3-4 m 4-5 m 5-6 m more than 6 m 25 40 63 100 4-way discharge 4-way discharge 4-way discharge 4-way discharge Wide discharge Wide discharge Wide discharge Wide discharge Louver Louver Cone Cone Louver Wide discharge Cone Cone Cone Louver Cone Cone Cone Cone This accessory selection table is no longer valid at a temperature differential ∆tL vof more than 30 K because of the reduced penetration depth. 40 TopWing Planning information TLH / TLHK TLH unit heaters: Induction louver with secondary-air cone Clearances TLH Clearances, wall-mounted units and clearances, ceiling-mounted units, louvers vertical Ceiling-mounted units, louvers angled toward side 25 40 63 100 Wall-mounted units: TLH to TLH TLH to side wall 7-9 m 3-4 m 9-11 m 3-5 m 11-13 m 4-6 m 13-15 m 5-7 m Ceiling-mounted units: TLH to TLH TLH to side wall -12 m 4-6 m -14 m 5-7 m -16 m 6-8 m -18 m 7-9 m TLHK TLHK to TLHK TLHK to side wall Throw, wall-mounted units 63 100 11-13 m 4-6 m 13-15 m 5-7 m 25 40 63 100 Type 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 at high speed 19 18 16 15 27 26 23 21 29 27 25 23 36 35 34 32 at low speed 16 15 13 12 20 19 16 14 22 20 18 17 30 28 26 25 Throw [m]* 0,2m/sec. Angle of adjustment Installed height min. 2,5m min. 4,0m 40 9-11 m 3-5 m TLH Throw m TLHK Throw [m]* Within range, air flow rate 0.2 m/sec. Height, ceiling-mounted units Installed height [m] 25 7-9 m 3-4 m Angle of adjustment 25 40 63 100 15 21 23 32 * Figures as stated in the table represent throw under defined operating conditions with a mixedair temperature 10 K above room temperature. Throw is shorter when the mixed-air temperature is more than 10 K above room temperature. TLH 25 40 63 100 Type 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Installed height [m]* 5 4,5 4 3,5 6 5,5 5 4,5 7 6,5 6 5,5 8 7,5 7 6,5 * The optimum angle of the louvres depends on the conditions of the room. Greater installation heights on request. Within range, air flow rate 0.2 m/sec. 41 TopWing Planning information TLH TLHK, Type 4 Water resistance [kPa] TLH 25 TLH 40 Water flow rate (m³/h) Water flow rate (m³/h) 1 0,5 Type 2 10 5 1 Type 3 TLHK 5 1 Type 1 5 0,5 Type 4 2 1 0,5 0,2 50 100 10 1 100 50 10 50 100 10 5 Type 3 5 10 50 100 1 5 10 50 100 1 TLHK Type 4 Water flow rate (m³/h) 5 Type 2 Type 3 TLHK Type 4 1 0,5 5 1 50 100 10 10 5 50 100 10 50 100 Water flow rate w (m³/h) 0,86 • Q ∆tW Q = Heating power ∆tw = Flow/return temperature differential Pages 38 - 39: Throw (depending on air temperature increase and discharge accessories) Pages 40: Speed (in conjunction with multi-stage switch) Pages 41: Speed (in conjunction with multi-stage switch) Pages 42: Heating power Air flow rate and air discharge temperature (depending on accessories and speed) 2 1 500 50 100 10 5 1 10 5 2 5 Type 1 10 10 50 5 100 20 100 50 100 10 0,5 1 5 10 50 100 0,5 1 5 10 50 100 Type 3 TLHK Type 4 50 5 1 Type 2 10 5 TLH 100 1 500 50 100 1 Water flow rate (m³/h) Type 1 42 Type 2 10 TLH 63 0,5 w= 5 Type 1 10 5 2 1 0,5 Frost protection by mixing in antifreeze: If low temperatures are to be expected (outdoor air operation) or if the cooling system is installed in a cold environment, an adequate amount of antifreeze should be mixed into the circulating water. The addition of antifreeze reduces the specific thermal capacity of the water. For example, the specific thermal capacity of ethylene glycol (trade name Antifogen N) is 2.357 kJ/kgK, so at the same output, the volume of circulating water must be increased. The water resistance also increases. Freezing point (°C) Antifreeze (Vol%) Increase in water resistance. -40 50 -20 -30 40 45% 30 30% -10 ±0 20 10 0 15% 0% TopWing Planning information TLH Horizontal throw Horizontal throw is the distance travelled by the air discharged by the TLH wall-mounted heater with discharge louver (m³/h) Air volume (m³/h) Luftmenge TLH 25 Heat increases (K) Lufterwärmung (K) 20 10 30 20 30 2100 2100 2000 2000 1800 1800 1600 1600 1400 1400 1200 1200 1000 1000 55 10 10 15 15 20 25 30 35 25 30 35 30 30 35 35 Wurfweite (m) Air throw (m) TLH 40 Heat increases (K) Lufterwärmung (K) 30 30 Air volume (m³/h) (m³/h) Luftmenge 3500 3500 3400 3400 20 10 3200 3200 3000 3000 2800 2800 2600 2600 2400 2400 2200 2200 2000 2000 10 15 55 10 15 Air throw (m) Wurfweite (m) Air volume (m³/h) (m³/h) Luftmenge TLH 63 20 Heat increases (K) Lufterwärmung (K) 30 30 20 5300 5300 5000 5000 10 4600 4600 4200 4200 3800 3800 3400 3400 3000 3000 55 10 10 15 15 20 20 25 25 Wurfweite (m) Air throw (m) TLH 100 Heat increases (K) Lufterwärmung (K) 30 20 30 20 9000 9000 10 10 (m³/h) Luftmenge Air volume (m³/h) 8500 8500 8000 8000 7500 7500 7000 7000 6500 6500 6000 6000 5500 5500 5000 5000 55 10 10 15 15 20 20 25 25 30 30 35 35 Air throw (m) Wurfweite (m) Example: TLH 100 with discharge louver ∆tL = tLAeff - tRaum = 20 K; air flow rate = 7300 m³/h Result: horizontal throw = 17m 43 TopWing Planning information TLH Vertical throw Vertical throw is the distance travelled by the hot air discharged by the TLH wall-mounted heater with discharge louver / swirl- wide discharge/ wide discharge Heat increases (K) Lufterwärmung (K) 50 30 20 15 Heat increases (K) Lufterwärmung (K) 10 3 2100 2000 (m /h) Luftmenge Air volume (m³/h) Air volume (m³/h) (m3/h) Luftmenge TLH 25 with discharge cone / discharge nozzle 1800 1600 1400 1200 10 60 40 30 20 15 3500 3400 3 2600 2400 2200 6 8 10 60 40 30 20 15 12 20 15 10 12 10 12 10 3200 2800 2600 2400 2 4 Wurfweite (m) Air throw (m) 6 8 Heat increases (K) Lufterwärmung (K) 10 3 4600 4200 3800 3400 60 50 40 5300 5000 30 25 20 4600 4200 3800 3400 3000 6 8 10 12 4 2 Wurfweite (m) Air throw (m) Heat increases (K) Lufterwärmung (K) 60 40 30 20 15 6 8 Heat increases (K) Lufterwärmung (K) 10 60 50 40 9000 8500 8500 8000 8000 Air volume (m³/h) Luftmenge (m /h) 7500 3 3 10 3000 2000 12 Luftmenge (m /h) Air volume (m³/h) 3 Luftmenge (m /h) Air volume (m³/h) 2 4 Wurfweite (m) Air throw (m) 2 4 Wurfweite (m) Air throw (m) Luftmenge (m /h) Air volume (m³/h) 8 2200 3000 7000 6500 6000 5500 30 25 20 15 7500 7000 6500 6000 5500 5000 5000 2 4 Wurfweite (m) Air throw (m) 44 60 40 30 Heat increases (K) Lufterwärmung (K) 9000 6 Heat increases (K) Lufterwärmung (K) 2800 TLH 100 10 1400 2 4 Wurfweite (m) Air throw (m) 10 3000 5300 5000 15 1600 12 (m /h) Luftmenge Air volume (m³/h) Air volume (m³/h) (m3/h) Luftmenge 8 6 3200 TLH 63 20 1800 Heat increases (K) Lufterwärmung (K) 2000 30 1000 2 4 Wurfweite (m) Air throw (m) 3500 3400 60 50 40 1200 1000 TLH 40 2100 2000 6 8 10 12 2 4 Wurfweite (m) Air throw (m) 6 8 10 12 TopWing DrehzahltabelleTLH Table of speeds for TLH fan motors Line voltage Stage Single-stage switch TLH 25 TLH 40 TLH 63 TLH 100 Speed min Speed min Speed min Speed min-1 -1 -1 -1 3 x 400 V - 1350 1350 900 900 3 x 400 V Y - 1000 1000 700 700 3 x 400 V II 1350 1350 900 900 3 x 400 V Y I 1000 1000 700 700 III 1350 1350 900 900 II 1150 1150 800 750 Two-stage switch Three-stage switch 3 x 400 V 3 x 400 V Y 1 x 230 V I 750 800 550 500 III 1000 1000 700 700 II 700 800 500 500 I 400 450 300 300 III 1350 1350 900 - II 1250 900 750 - I 750 600 500 - V 1350 1350 900 900 IV 1280 1250 850 800 III 1150 1150 800 750 II 950 950 700 650 I 750 800 550 500 Five-stage switch 3 x 400 V 3 x 400 V Y 1 x 230 V V 1000 1000 700 700 IV 900 900 600 600 III 700 800 500 500 II 550 600 400 350 I 400 450 300 300 V 1350 1350 900 - IV 1300 1100 800 - III 1250 900 750 - II 1200 750 650 - I 750 600 500 - 45 TopWing Sound pressure levels TLH / TLHK Sound pressure levels / sound power levels as a function of speed Speed min-1 1350 1280 1150 1000 950 900 750 700 550 400 360 280 210 160 1350 1300 1250 1200 750 630 500 430 360 280 210 160 Speed TLH 25 Sound power level dBA 3 x 400V 70 69 67 64 63 61 57 56 51 44 41 36 30 24 1 x 230V 70 69 68 68 57 54 49 45 41 36 30 24 TLHK 25 Sound power level dBA Sound pressure level* dBA 2m Speed 59 58 56 53 52 50 46 45 40 33 30 25 19 13 1350 1250 1150 1000 950 900 800 600 450 400 360 280 210 160 59 58 57 57 46 43 38 34 30 25 19 13 1350 1100 900 750 600 500 430 360 280 210 160 Sound pressure level* dBA min-1 2m 3 x 400V Heating 1350 70 59 1000 64 53 750 57 46 1 x 230V Cooling 1350 70 59 1000 64 53 750 57 46 3 x 400V Heating 810 59 48 570 51 40 410 44 33 1 x 230V Cooling 810 60 49 570 52 41 410 45 34 min-1 Speed TLH 40 Sound power level dBA 3 x 400V 74 72 71 68 66 65 63 56 50 48 45 40 34 28 1 x 230V 72 68 63 59 54 51 47 43 38 32 26 TLHK 40 Sound power level dBA Sound pressure level* dBA 2m Speed min-1 TLH 63 Sound power level dBA 63 61 60 57 55 54 52 45 39 37 34 29 23 17 900 850 800 700 600 550 500 400 300 260 210 160 61 57 52 48 43 40 36 32 27 21 15 900 800 750 650 500 430 360 280 210 160 Sound pressure level* min-1 dBA 2m 3 x 400V Heating 1350 74 63 1000 68 57 750 61 50 1 x 230V Cooling 1350 72 61 1000 66 55 750 59 48 3 x 400V Heating 810 63 52 570 55 44 41 48 37 1 x 230V Cooling 810 61 50 570 53 42 410 46 35 Speed Sound pressure level* dBA 2m Speed min-1 TLH 100 Sound power level dBA 3 x 400V 70 69 67 65 61 59 57 52 46 43 39 33 59 58 56 54 50 48 46 41 35 32 28 22 900 800 750 700 650 600 500 350 300 260 210 160 3 x 400V 74 71 70 69 67 65 61 54 50 47 43 37 63 60 59 58 56 54 50 43 39 36 32 26 1 x 230V 70 67 66 63 57 54 50 45 39 33 59 56 55 52 46 43 39 34 28 22 - 1 x 230V - - TLHK 63 Sound power level dBA Sound pressure level* min-1 dBA 2m 3 x 400V Heating 900 70 59 700 65 54 500 57 46 1 x 230V Cooling 900 70 59 700 65 54 500 57 46 3 x 400V Heating 540 59 48 380 51 40 270 44 33 1 x 230V Cooling 540 49 48 380 51 40 270 44 33 * Sound pressure level for a room with medium absorption characteristics, enclosed space approximately 1500 m³. 46 Speed TLHK 100 Sound power level dBA Sound pressure level* dBA 2m Sound pressure level* min-1 dBA 2m 3 x 400V Heating 900 74 63 700 69 58 500 61 50 1 x 230V Cooling 3 x 400V Heating 540 53 52 380 55 44 270 48 37 1 x 230V Cooling - TopWing Leistung in Abhängigkeit vom Zubehör Symbols in formula Conversion: 1 Pa = 0,1 mm WS 1 kPa = 1000 Pa V = Volume flow VB = Reference volume flow VO = Catalog volume flow Veff = Effective volume flow tLE = Air intake temperature tLA = Air discharge temperature tLAeff= Effective air discharge temperature ∆tL = Air-temperature increase ∆tW = Temp. spread of the water W = Water flow rate Q = Heating power QO = Catalog heating power Qeff = Effective heating power ∆p = Air resistance ∆pW = Water resistance e = Heat-rise factor qeff = Heating power factor leff = Air flow rate factor K = Accessory index of the entire heater Accessory index k: Mixed-air box 3 Four-way discharge 2 Discharge nozzle 2 Discharge cone 2 Wide discharge 0 Swirl-wide discharge 1 Filter, clean 5 Rain cowl 2 Weatherproof screen 7 Weatherproof screen with flow-stop louver 9 Flow-stop louver 3 Outdoor-air box 0 Recirculated-air box 0 Intake cowl 1 Induction louver with secondary-air cone 2 m³/h m³/h m³/h m³/h °C °C °C K K m³/h kW kW kW Pa kPa k = 0,1 • ∆ p • ( Worked example Given: TLH 100 type 4, tLE = -5°C, PWW 50/40 from performance table on page 10: (always read off the higher speed, because correction factors for operation at lower speeds are taken into account in the charactersitics graph.) VO = 7700m³/h QO =96,1kW tLA = 29 °C ∆tLO = (29+5)K = 34K Calulate k for non-Wolf accessories as follows: VB V TLH Line voltage 3 x 400 V Δ with 5-stage switch, switch stage 1 from speeds table on page 41: 500 min-1 )2 Accessories: mixed-air box and filter accessories by others: fresh-air duct ∆p =Air resistance (Pa) at V (m³/h) V =Volume flow rate (m³/h) at ∆ p (Pa) TLH VB 25 2000m³/h 40 3000m³/h ∆p k k k k kges 63 6000m³/h TLH 100, 500rpm, k = 12 100 10000m³/h from characteristics graph: ( ) leff =0,4 e =1,35 qeff=0,55 Speed (min-1) TLH63/TLH100 Characteristics graph Speed (min-1) TLH25/TLH40 = 10Pa bei 5000m³/h =0,1 • 10 • 10000 2 5000 = 4 (duct), = 3 ((mixed-air box) = 5 (filter) = 4 + 3 + 5 = 12 Find: Effective air flow rate Veff Effective air-temp. increase ∆tL eff Effective air discharge temp. tLA eff Effective heating power Qeff Water throughput W Water resistance ∆pw Solution: Veff = VO • leff = 7700m³/h • 0,4 = 3080m³/h ∆tL eff = ∆tLO • e = 34K • 1,35 = 45,9K tLA eff = tLE + ∆tL eff = -5 + 45,9°C = 40,9°C Qeff = QO • qeff = 96,1kW • 0,55 = 52,9kW leff e (Air flow rate factor) (Heat rise factor) qeff(Heating power factor) w = 0,86 • Qeff = 0,86 • 52,9 = 4,5m³/h ∆tw 10 ∆pw (from diagram on page 34) = 8,5kPa ∆pw (Diagramm Seite 34) = 8,5kPa 47 TopWing Number of cores / Weights Number of cores for connecting cables TLH / TLHK Connection from to Switchgear D1-2 DS-2 A2 D3-4 D5.. E3-7T E5-7T A1 A1S supply 5 5 5 5 5 3 3 - - TLH-motor 3x400V 6 9 9 6 6 - - - - TLH-motor 1x230V - - - - - Room thermostat 3/4 3/4 5 3/4 3/4 3/4 3/4 - - 5 5 62) 5 5 5 - - - Automatic relay, A1 4 4 4 4 4 4 4 - - Servomotor - - - - - - - 4 6 Room thermostat with clock 1) 1) 2) 1) 5 1) 5 1) 1) If using a room thermostat with thermal feedback.. 2-stage. Make the connection to the frost stat using 3 cores. 1) 2) Weights in kg Basic Unit 25 40 63 100 TLH Unit heater, type 1 26 35 51 80 TLH Unit heater, type 2 28 38 54 86 TLH Unit heater, type 3 29 39 55 88 TLH Unit heater, type 4 30 41 57 92 TLHK Unit heater 32 44 64 101 Mixed-air box 26 32 42 68 Outdoor-air box (only TLH) 15 27 29 47 Recirculated-air box 16 28 31 50 Filter box 13 16 20 37 Rain cowl 13 19 30 43 Roof penetration 22 27 37 48 Intake cowl 2 5 6 20 Flow-stop louver 2 2 4 5 Weatherproof screen 6 9 14 20 Weatherproof screen with flow-stop louver 8 11 18 25 Discharge nozzle 5 7 10 14 Discharge cone 4 12 19 27 Wide discharge 4 7 11 16 Swirl-wide discharge 4 7 11 16 Four-way discharge 5 7 13 16 Induction louver with Secondary-air cone 4 5 8 10 3 3 9 9 Intake accessories Discharge accessories (only TLH) Other supporting brackets (1set) 48 TopWing Texts for quoations Pos. Qty. TLH Unit heater, basic unit Part No. Unit price Total price for operation in mixed-air, outdoor-air and recirculated-air modes and for wall-mounted and ceiling-mounted installation. Housing welded, galvanized and powder-coated sectional frame, skin panels powder-coated, color standard white RAL 9016 with improved thermal insulation through fitted PU soft-foam insulation, 25mm thick. Discharge louver with individually adjustable deflector vanes, powdercoated, color Wolf silver, similar to RAL 9006.. Axial-flow fan with aluminum cresent-wing rotor, for low-noise operation, with protective screen. Fan/motor unit on vibration damper, 230V, 50Hz, alternatively 3 x 400V, 50Hz, Degree of protection IP 54, heat class CL F, through switchgear up to 5 stages, Winding protection by integral thermal contacts. Heat exchanger pulls to one side for removal Cu/Al, steel header (or copper as alternative), ports with inch system threads, threaded adapters for PN 16 up to 140°C. Water flow/return on air discharge side top/bottom. Technical specifications: Volume flow rate Heating power Air temp. rise from Heating medium Water resistance Motor speed Motor power Operating voltage Rated current Degree of protection ......................................................m³/h ......................................................kW .......................... to........................°C ...................................................... / ......................................................kPa .......................... rpm .......................... kW .......................... V .......................... A ......................................................IP °C Dimensions: Length:........................................mm Width:.........................................mm Height:........................................mm Weight:.......................................kg Make: Wolf Type: TLH 49 TopWing Texts for quoations Pos. Qty. TLHK Unit heater, basic unit Part No. For recirculation air mode, or alternatively mixed air mode, for wall mounting. With infinitely adjustable induction louvre and secondary air cone fitted to the unit. Housing welded, galvanized and powder-coated sectional frame, skin panels powder-coated, color standard white RAL 9016 with with improved thermal insulation through fitted PU soft-foam insulation, 25mm thick. Induction louver with secondary air cone color standard white RAL 9016 for wall-mounted units to optimise the throw and temperature distribution, alternative: with servomotor 230 V / 50 Hz with servomotor 24 V / 50 Hz manually adjustable, no motor Axial-flow fan with aluminum cresent-wing rotor, for low-noise operation, with protective screen. Fan/motor unit Fan motor unit with anti-vibration mounts, 230 V, 50 Hz, alternatively 3 x 400 V, 50 Hz, degree of protection IP 54, heat class CL F, Winding protection by integral thermal contacts. Heat exchanger Heat exchanger type 4, two-line system for pumped hot water PWW or pumped cold water PKW with copper pipes and aluminium louvres, manifold steel (or copper as alternative) threaded connector PN 16. Heat exchanger can be removed at the side. Cooling mode Aluminium condensate pan with a fall, integrated into the unit. Unit with ½“ drain connector on the bottom for free drainage or ready for connection to a hose. Technical specifications: Volume flow rate Heating power Air temp. rise from Heating medium Water resistance Motor speed Motor power Operating voltage Rated current Degree of protection ......................................................m³/h ......................................................kW .......................... to........................°C ...................................................... / ......................................................kPa .......................... min-1 .......................... kW .......................... V .......................... A ......................................................IP Dimensions: Length:........................................mm Width:.........................................mm Height:........................................mm Weight:.......................................kg Make: Wolf 50 Type: TLHK °C Unit price Total price TopWing Texts for quoations Pos. Qty. Intake accessories TLH / TLHK TLH TLHK Mixed-air box without isolation with integral dampers for outdoor air on the back and recirculation air on the side; can be adjusted manually or with damper servomotor; powder-coated, colour standard white RAL 9016 • • Mixed-air box with isolation with integral dampers for outdoor air on the back and recirculation air on the side; can be adjusted manually or with damper servomotor; powder-coated, colour standard white RAL 9016 • • Outdoor-air box with air intake at the rear for connection to a wall penetration or outdoor-air duct; powdercoated, color standard white RAL 9016 • Louver flap for outdoor-air box. • Recirculated-air box with two side screens for recirculated-air intake; powdercoated, color standard white RAL 9016 • • Filter box complete with replaceable filer element, filter class G4 for TLH-(K) 63, filter class G4 for TLH-(K) 25, TLH-(K) 40, TLH-(K) 100; powdercoated, color standard white RAL 9016 • • Rain cowl with birdproof screen, sheet steel, galvanized. • • Roof penetration, sheet steel, galvanized. • • Flashing for roof penetration, sheet steel, galvanized. • • Intake cowl with birdproof screen, sheet steel, galvanized. • • Flow-stop louver for rain/intake cowl, sheet steel, galvanized. • • Weatherproof screen with birdproof screen without flow-stop louver, sheet steel, galvanized. • • Weatherproof screen with birdproof screen and flow-stop louver, sheet steel, galvanized. • • Sailcloth adapter on 4-hole sectional frame, sheet steel, galvanized. • • Part No. Unit price Total price 51 TopWing Texts for quoations Pos. Qty. Discharge accessories TLH / TLHK TLH TLHK Discharge nozzle for extra-long throw, suitable for use as air curtain; powdercoated, color standard white RAL 9016 • Discharge cone for high-ceilinged rooms to extend throw; powdercoated, color standard white RAL 9016 • Four-way discharge with adjustable side deflector vanes for low-ceilinged rooms; powdercoated, color standard white RAL 9016; Vanes Wolf color Wolf silver, similar to RAL 9006. • Wide discharge with individually adjustable vertical and horizontal deflector vanes for warm-air current up to 120° spread, powdercoated, color Wolf silver, similar to RAL 9006. • Swirl wide discharge with individually adjustable vertical and horizontal deflector vanes for warm-air current up to 120° spread, powdercoated, color Wolf silver, similar to RAL 9006. • Induction louver with secondary-air cone, color standard white RAL 9016 for wall-mounted heater for optimized throw and temperature distribution, alternative: with servomotor 230 V / 50 Hz with servomotor 24 V / 50 H manually adjustable, no motor • • • Induction louver with secondary-air cone, color standard white RAL 9016 for ceiling-mounted heater for optimized throw and temperature distribution, alternative: with servomotor 230 V / 50 Hz with servomotor 24 V / 50 H manually adjustable, no motor • • • Miscellaneous 52 Shut-off set for flow and return, straight-through version • • Absperrset for flow and return, angled version • • Supporting brackets for wall-mount and ceiling-mount installation of the TLH heater, powdercoated, color standard white RAL 9016. • • Fixing set for installing the TLH-(K)-25/40 unit on a vertical concrete beam, sheet steel, galvanised • • Fixing set for installing the TLH-(K)-25/40 unit on a vertical steel beam, sheet steel, galvanised • • Fixing set for installing the TLH-(K)-25/40 unit on a horizontal or tilted steel beam, without self-aligning brackets, sheet steel, galvanised • Fixing set for installing the TLH-(K)-25/40 unit on a tilted steel beam, with self-aligning brackets, sheet steel, galvanised • Suspension brackets for wall-mount and ceiling-mount installation of theintake accessories, powdercoated, color standard white RAL 9016. • • Hangers for horizontal (TLH/TLHK)or vertical (TLH) installation of the heater, powdercoated, color standard white RAL 9016. • • Differential pressure switch 20 - 300Pa; Degree of protection IP 54 • • Part No. Unit price Total price TopWing Texts for quoations Pos. Qty. Electrical accessories TLH / TLHK TLH TLHK Single-stage switch, D1-2 Motor thermistor-type protection switch with restart disablement for singlespeed fan operation. Capacity, max. 8A, Operating voltage 400V, Control voltage 230V, Degree of protection IP 54; dimensions W x H x D: 150 x 200 x 175mm. • Two-stage switch, DS-2 Motor thermistor-type protection switch with restart disablement for twospeed fan operation. Capacity, max. 8A, Operating voltage 400V, Control voltage 230V, Degree of protection IP 54; dimensions W x H x D: 200 x 300 x 190mm. • Three-stage switch, D3-4 Motor thermistor-type protection switch with restart disablement for three-speed fan operation. Capacity, max. 4A, Operating voltage 400V, Control voltage 230V, Degree of protection IP 20; dimensions W x H x D: 230 x 310 x 185mm. • Five-stage switch, D5-1 Motor thermistor-type protection switch with restart disablement for fivespeed fan operation. Capacity, max. 1A, Operating voltage 400V, Control voltage 230V, Degree of protection IP 40; dimensions W x H x D: 150 x 200 x 175mm. • Five-stage switch, D5-3 Motor thermistor-type protection switch with restart disablement for fivespeed fan operation. Capacity, max. 2A, Operating voltage 400V, Control voltage 230V, Degree of protection IP 20; dimensions W x H x D: 230 x 310 x 185mm. • Five-stage switch, D5-7 Motor thermistor-type protection switch with restart disablement for fivespeed fan operation. Capacity, max. 4A, Operating voltage 400V, Control voltage 230V, Degree of protection IP 20; dimensions W x H x D: 230 x 310 x 185mm. • Five-stage switch, D5-12 Motor thermistor-type protection switch with restart disablement for fivespeed fan operation. Capacity, max. 7A, Operating voltage 400V, Control voltage 230V, Degree of protection IP 20; dimensions W x H x D: 230 x 310 x 185mm. • Three-stage switch, E3-7T Motor thermistor-type protection switch with restart disablement for three-speed fan operation with single-phase AC motor. Capacity, max. 7A, Operating voltage 230 V, Degree of protection IP 40; dimensions W x H x D: 150 x 200 x 175mm. • Control connection box for Wolf boiler controller. • All-pole-isolating repair switch type AR8. • Part No. Unit price Total price 53 TopWing Texts for quoations Pos. Qty. Electrical accessories TLH / TLHK TLH TLHK Intermediate terminal box for parallel operation of up to 3 TLH heaters. • Earth strap for equipotential bonding • • Frost-protection thermostat, mounted on the TLH(-K) heater Length of capillary sensor 1,5m or 3m. • • Room thermostat for surface mounting with thermal feedback. Switching capacity 10(4)A at 230V, temperature range 5-30°C, Degree of protection IP 30; dimensions W x H x D: 75 x 75 x 25mm. • Room thermostat with summer/winter switch for switching from heating to ventilation; for surface mounting, with thermal feedback. Switching capacity 10 (4) at 230V, temperature range 5-30°C, Degree of protection IP 30; dimensions W x H x D: 75 x 75 x 25mm. • Room thermostat, industrial grade Switching capacity 16 (4) A at 230V, temperature range 0-40°C, Degree of protection IP 54; dimensions W x H x D: 110 x 150 x 72mm. • Thermostatic timer with week programs For installation in a plug-in base; day and night temperatures can be adjusted separately. Temperature setback can be adjusted by 2-10 K. Switching capacity 10(4) A at 230V, temperature range 5-40°C, Degree of protection IP 20; dimensions W x H x D: 132 x 82 x 32mm. • Remote sensor for room thermostat clock For installation in plug-in base, Degree of protection IP 54. dimensions W x H x D: 52 x 50 x 35mm. • Servomotor for stepless flap control or stepless mixer control, 230V /50Hz. • Servomotor for stepless flap control 24V. 54 • • Servomotor for flap open/close 230V / 50Hz. • Automatic relay, A1 for servomotor (open/close). • Automatic relay, A1S with position controller for servomotor (stepless). • • Position controller for installation in front panel of switchgear cabinet for actuating the servomotor (stepless) in conjunction with automatic relay A1. • • Position controller for surface mounting for actuating the servomotor (stepless) in conjunction with automatic relay A1. • • Pushbutton For servomotor 230 V/50 Hz for induction louvre with secondayr air cone • • Part No. Unit price Total price TopWing Texts for quoations Pos. Qty. Electrical accessories WRS TLH / TLHK TLH TLHK BML ventilation programming module Room temperature-dependent control for regulating up to 7 zones with eBUS interface • • Wall mounting base for use with the BML ventilation programming module as remote control. • • LM1 ventilation control unit (incl. room temperature sensor) For room temperature-dependent control of air heaters with 2-stage motor • • LM2 ventilation control unit Room temperature controlled via mixer or speed in conjunction with EC motors with additional LM1 module, 2-stage motor control • • Outside or room temperature sensor • • Radio clock For synchronising the clock inside the control unit with the DC77 transmitter • • Radio clock with outside temperature sensor For synchronising the clock inside the control unit with the DC77 transmitter, and capturing the outside temperature • • Supply air sensor and sensor retainer • • 5-stage electronic switch D5-2F, D5-4F 400V/2A/4A To control air heaters Speed via an external 0-10 V signal • • 5-stage electronic switch E5-6F 230V/6A To control air heaters Speed via an external 0-10 V signal • • ISM 5 - LON-interface module to connect ventilation modules LM1 and LM2 to a building management system applying LON-standard network variables • • Part No. Unit price Total price 55 The comprehensive equipment range from system supplier Wolf offers the ideal solution for commercial and industrial buildings, for new build and for modernisation projects alike. The range of Wolf control units fulfils every need where heating convenience is concerned. The products are easy to operate, energy-efficient and reliable. Photovoltaic and solar heating systems can be quickly integrated into existing systems. All Wolf products can be easily and rapidly commissioned and maintained. The competent brand for energy saving systems 56 Part no. 48 00 439 GB 201402 Subject to technical modifications Wolf GmbH, PO Box 1380, D-84048 Mainburg, Tel.: +49 87 51 / 74-0, Fax: +49 87 51 / 74-1600, Internet: www.wolf-heiztechnik.de