D50 0 - D520 SELECTION TABLE Vdc D5020S Passive Tx tech
Transcription
D50 0 - D520 SELECTION TABLE Vdc D5020S Passive Tx tech
D50 0 - D520 SELECTION TABLE Field device Model Hazardous Area ChI> per unit Safe Area 4-20mA (source' only) 2-Wires Tx only; 20-30 Vdc Smart compati.ble 2 050145 1 4·..20mA (source or sink) 4-20 rnA D5014D Sit level 1 05011S D5011D Suppty 2-Wires Active or Passive Tx; 2 20-30 Vdc Smart compatible Two duplicated outputs. D5014D 1 4-20mA + Modbus 4-20 mA Two duplicated outputs + Modbus 2-Wires Passive Tx One Triplicate'd + One singLe 20-30 outputs Vdc 2 + Modbus One Quadriplicatedoutput 1 + Modbus D5020S 4-20mA 2-Wires Tx Active or Passive; Smart compatible 4-20mA 2 Trip Amplifiers each whit 1 SPST (relay contact) + Modbus 1 iI-20mA, 4..20mA 1 Analog Signal to lIP Bus powered signal from DeS, pte or other control devices .. Converters, Electroyaives, D-5020D Actuators and Displays; Smart compatible FOR MORE INFORMATION Two dupUcated outputs .. - PLEASE, CONT~CT 1.0-30 Vdc ~ 5.iL 1 , -20-30 Vdc 2 US ! tech'nology' for safety PAGE 1 0'5000 - 0520 Field device SELECTION TABLE sa Ch.. Model Hazardous Area D50305 Voltage free Contact, D5030D, Proximity Switch line fautt detecnon Isolated inputs per unit 1SPOT (relay cmtact) + lID (fault status) 1 1SP5f (retaycmtact) + 1 SPST (alann adupti:atcr) + lED level 20-30 Vdc 1 + lED (fault status) Voltage free Contact, Proximity Switch Line fault detection Isolated inputs Supp,ty 2 1Open Cdlector 050315 1 (fault status) 2SPST~<mtact) + l.ED (fault status) D5030D D50310 Safe Area 2'Open Cdlectas status) 1 + l.£D(fault 20",]0 Vdc 1Open Cdlectcr D5031D + 1 0 ..C, (alann duplkator) 2 + lED (fault status) Voltage free Contact, Proximity Switch line fault detection (fait status) 20..30 Vdc + Modbus 1 SPOT' (relayantact) D5'0325 + tED Voltage free Contact" D5032D 8 Open Cdtecb:J3 + lED Proximit.y Swit.ch Line fault detection Isolated inputs 1 (fault status) 1SP5f(relay'COltact) + 1 SPST (alann ordtplicator) + lED (fauttstatus) 2'SPST (relaycootact) + tED (fault Lj,ne fault detection Isolated -inputs 20-30 Vdc 2 status) 050345 Voltage free Contact, Proximity Switch 1 1 Transparent input o to repeater of 20-30 status 8 mA Vdc range D5034D 2 FOR MORE INFORMATION - PLEASE, CONTACT us ! DTS0262-2 PAnp, 2. 05000 - 520 field -device Model D5048S 05,049S SELECTION TABLE Hazardous Area NE solenoid valve, other control devkes. line open/short fault detection reflected on PLC.. loop Powered control signal from safety 1 pte, DeS Bus Powered controt signal from safety 1 pte, DeS FaG solenoid valve, other control devices ..tine open! short fault detection. High Availability (1002) 0-50 KHz Magnetic Pickup or 052655 o u or V Intrinsically Safe Encoder Transparent repeater 1 4-20 rnA (source or sink) + Modbus 1 Independent set point via 1 Solid State Relay 1 Universal TC, 3-Wires RTD, Potentiometer, mV 4-20 rnA (source or sink) + Modbus 4,·20 rnA + 314-Wires RTD$ Pot; mV FOR MORE INFORMATION ~+ 2O-11Vdc (source or sink) Vdc Vdc 2 Modbus 4- 20 rnA (source or sink) 2 independent set points via 1 SPDT Relay each + Modbus 20-30 20-30 20-30 Vdc Duplicator Universal TC, Vdc Out, 1 ti UJ > z: rnA. (source) 1 Proximity Switch 3/4,-Wires RTD, Potentiometer, mY' tI) from safety PlC, OCS Pulse repeater Output + Modbus Universal TC, .0:: W Loop Powered control signal 20-30 1 21 :J. :J21 SIt.. SIt.. 20-30 Vdc - PLEASE" CONTACT US ! technology for safety PAGE 3 D5 00 - 05200 ACCESSORIES Code JDFT049 Description 12 mm Power Bus Connector for DIN Rail Mounting 1 needed for each BUS Module -_._-------_._-----------------JDFT050 22 mm Power Bus Connector for DIN 'Rail Mounting 1 needed for each BUS Module ---------------------------------------------------------------------------~--MCHP196 Bus End Stopper One for each end of Bus Required MOR017 Plug-in terminal block male, horizontal out, for Power Bus MOR022 Plug-in terminal block female, horizontal out, for Power Bus MCHP'183, Blue Terminal MCHP184 Grey' MCHP'18;S Blue Terminal ,Btock Plug 22 mm Btock Plug 12 mm Terminal 'Block Plug 12 mm ,------"-----------MCH,P18,6 Grey Terminal Btock Plug 22 mm ---_.----,-------_.OPT5096 Kit for Bus Mounting: 1 x MOR017, 1 x MOR022~ 2 PPC,5092 PC Adapter required x MCHP196 to configure -programmable units; Mini USB Male to USB,Port SWC5090 PC Software for Configuration FOR MORE INFORMATION - PLEASE, CONTACT US' '! 'DTS0262'...2 PAnF·4