D50 0 - D520 SELECTION TABLE Vdc D5020S Passive Tx tech

Transcription

D50 0 - D520 SELECTION TABLE Vdc D5020S Passive Tx tech
D50 0 - D520
SELECTION TABLE
Field
device
Model
Hazardous Area
ChI>
per unit
Safe Area
4-20mA
(source' only)
2-Wires Tx only;
20-30
Vdc
Smart compati.ble
2
050145
1
4·..20mA
(source or sink)
4-20 rnA
D5014D
Sit
level
1
05011S
D5011D
Suppty
2-Wires
Active or Passive
Tx;
2
20-30
Vdc
Smart compatible
Two
duplicated outputs.
D5014D
1
4-20mA
+ Modbus
4-20 mA
Two
duplicated outputs
+ Modbus
2-Wires
Passive Tx
One Triplicate'd
+ One singLe
20-30
outputs
Vdc
2
+ Modbus
One
Quadriplicatedoutput
1
+ Modbus
D5020S
4-20mA
2-Wires Tx
Active or Passive;
Smart compatible
4-20mA
2 Trip Amplifiers each
whit 1 SPST (relay contact)
+ Modbus
1
iI-20mA,
4..20mA
1
Analog Signal to lIP
Bus powered
signal from DeS, pte or other
control devices ..
Converters, Electroyaives,
D-5020D
Actuators and Displays;
Smart compatible
FOR MORE INFORMATION
Two dupUcated
outputs ..
- PLEASE, CONT~CT
1.0-30
Vdc
~
5.iL 1
,
-20-30
Vdc
2
US !
tech'nology' for safety
PAGE 1
0'5000 - 0520
Field
device
SELECTION TABLE
sa
Ch..
Model
Hazardous Area
D50305
Voltage free Contact,
D5030D,
Proximity Switch
line fautt detecnon
Isolated inputs
per unit
1SPOT (relay cmtact)
+ lID (fault status)
1
1SP5f (retaycmtact)
+ 1 SPST (alann adupti:atcr)
+ lED
level
20-30
Vdc
1
+ lED (fault status)
Voltage free Contact,
Proximity Switch
Line fault detection
Isolated inputs
Supp,ty
2
1Open Cdlector
050315
1
(fault status)
2SPST~<mtact)
+ l.ED (fault status)
D5030D
D50310
Safe Area
2'Open Cdlectas
status)
1
+ l.£D(fault
20",]0
Vdc
1Open Cdlectcr
D5031D
+ 1 0 ..C,
(alann duplkator)
2
+ lED (fault status)
Voltage free Contact,
Proximity Switch
line fault detection
(fait status)
20..30
Vdc
+
Modbus
1 SPOT' (relayantact)
D5'0325
+ tED
Voltage free Contact"
D5032D
8 Open Cdtecb:J3
+ lED
Proximit.y Swit.ch
Line fault detection
Isolated inputs
1
(fault status)
1SP5f(relay'COltact)
+ 1 SPST (alann ordtplicator)
+ lED
(fauttstatus)
2'SPST (relaycootact)
+ tED (fault
Lj,ne fault detection
Isolated -inputs
20-30
Vdc
2
status)
050345
Voltage free Contact,
Proximity Switch
1
1
Transparent
input
o to
repeater
of
20-30
status
8 mA
Vdc
range
D5034D
2
FOR MORE INFORMATION
- PLEASE, CONTACT
us !
DTS0262-2
PAnp,
2.
05000 - 520
field
-device
Model
D5048S
05,049S
SELECTION TABLE
Hazardous Area
NE solenoid valve,
other control devkes.
line open/short
fault detection
reflected on PLC..
loop Powered control signal
from safety
1
pte, DeS
Bus Powered controt
signal
from safety
1
pte, DeS
FaG solenoid valve, other
control devices ..tine open!
short fault detection.
High Availability (1002)
0-50 KHz
Magnetic Pickup or
052655
o
u
or V
Intrinsically Safe Encoder
Transparent repeater
1
4-20 rnA (source or sink)
+ Modbus
1 Independent set point via
1 Solid State Relay
1
Universal TC,
3-Wires RTD,
Potentiometer,
mV
4-20 rnA (source or sink)
+ Modbus
4,·20 rnA
+
314-Wires RTD$
Pot; mV
FOR MORE INFORMATION
~+
2O-11Vdc
(source or
sink)
Vdc
Vdc
2
Modbus
4- 20 rnA (source or sink)
2 independent set points
via 1 SPDT Relay each
+ Modbus
20-30
20-30
20-30
Vdc
Duplicator
Universal TC,
Vdc
Out,
1
ti
UJ
>
z:
rnA. (source)
1
Proximity Switch
3/4,-Wires RTD,
Potentiometer, mY'
tI)
from safety PlC, OCS
Pulse repeater Output
+ Modbus
Universal TC,
.0::
W
Loop Powered control signal
20-30
1
21
:J.
:J21
SIt..
SIt..
20-30
Vdc
- PLEASE" CONTACT US !
technology for safety
PAGE 3
D5 00 - 05200 ACCESSORIES
Code
JDFT049
Description
12 mm Power Bus Connector for DIN Rail Mounting
1 needed for each BUS Module
-_._-------_._-----------------JDFT050
22 mm Power Bus Connector
for DIN 'Rail Mounting
1 needed for each BUS Module
---------------------------------------------------------------------------~--MCHP196
Bus End Stopper
One for each end of Bus Required
MOR017
Plug-in terminal block male, horizontal out, for Power Bus
MOR022
Plug-in terminal block female, horizontal out, for Power Bus
MCHP'183,
Blue Terminal
MCHP184
Grey'
MCHP'18;S
Blue Terminal ,Btock Plug 22 mm
Btock Plug
12 mm
Terminal 'Block Plug 12 mm
,------"-----------MCH,P18,6
Grey Terminal
Btock
Plug 22
mm
---_.----,-------_.OPT5096
Kit for Bus Mounting:
1 x MOR017, 1 x MOR022~ 2
PPC,5092
PC Adapter
required
x MCHP196
to configure
-programmable
units;
Mini USB Male
to USB,Port
SWC5090 PC Software for Configuration
FOR MORE INFORMATION
- PLEASE, CONTACT US' '!
'DTS0262'...2
PAnF·4