Quick Lift Anchors
Transcription
Quick Lift Anchors
Quick Lift Anchors 5-1 www.cfsfixings.com Contents Anchor Types 5-3 Type FSA - Spread Anchor 5-4 Type FSA - Load Capacities for Slabs and Thick Walled Products 5-5 Type FSA - Load Capacities for Thin Walled Products 5-6 Type FTH - Two Hole Anchor 5-8 Type FTH - Load Capacity and Additional Reinforcement Requirements 5-9 5-11 Tilting Anchor Load Capacity and Additional Reinforcement Requirements 5-12 Type FFA - Flat Foot Anchor 5-13 Type FFA - Capacity and Additional Reinforcement Requirements 5-14 Type FPA - Plate Anchor 5-15 Flat Plate Anchor Capacity and Additional Reinforcement Requirements 5-16 Quick Lift Clutch 5-17 Rubber Recess Former Bayonet 5-18 Holding Plate 5-19 Holding Screw 5-19 QUICK LIFT ANCHORS Type FE - Tilting Anchor 10 www.cfsfixings.com 5-2 Anchor Types Spread anchor type FSA Flat foot anchor type FFA Suitable for load ranges 0.7 t to 22.0 t for use in both thin panels and slabs. The additional hole in the anchor is for additional reinforcement which is used in certain special applications. This anchor is intended for use in slabs. Additional reinforcement is placed over the foot of the anchor. Two hole anchor type FTH Plate anchor type FPA Suitable for load ranges 0.7 t to 22.0 t similar to the spread anchor, except this anchor utilises additional reinforcement passed through the hole for anchorage. This anchor is suitable for use in the thinnest of slabs. Additional reinforcement is placed over the flat plate of the anchor. Erection anchor type FE This anchor is designed for tilting panels from the horizontal to the vertical. The anchor head is designed so that loads are not transferred to the upper part of the concrete surface. This avoiding spalling. 5-3 www.cfsfixings.com Type FSA - Spread Anchor The lifting anchor is made of St 52-3 steel with an additional hole. The stress transfer to the concrete occurs through the lower spead of the flat steel. It provides optimum anchoring whether used in thin walls or large concrete units. a c b d Part No Load Group Dimensions a b c CFS-FSA-0.7-110 110 5 CFS-FSA-1.4-110 110 6 CFS-FSA-1.4-160 160 6 CFS-FSA-2.0-130 130 8 d mm CFS-FSA-2.0-160 CFS-FSA-2.0-210 2.5 30 160 8 210 8 120 10 150 10 CFS-FSA-2.5-200 200 10 CFS-FSA-2.5-250 250 10 CFS-FSA-3.0-160 160 10 CFS-FSA-3.0-220 220 10 CFS-FSA-3.0-280 280 10 CFS-FSA-4.0-140 140 10 CFS-FSA-4.0-180 180 10 240 12 CFS-FSA-4.0-240 5 40 CFS-FSA-4.0-320 320 12 CFS-FSA-5.0-180 180 15 CFS-FSA-5.0-240 240 15 CFS-FSA-5.0-400 400 15 CFS-FSA-7.5-260 260 16 CFS-FSA-7.5-300 300 16 CFS-FSA-7.5-420 420 16 300 20 CFS-FSA-10-300 10 60 CFS-FSA-10-370 370 20 CFS-FSA-10-520 520 20 CFS-FSA-14-370 370 20 CFS-FSA-14-460 460 20 500 20 620 20 CFS-FSA-22-500 CFS-FSA-22-620 26 60 QUICK LIFT ANCHORS CFS-FSA-2.5-120 CFS-FSA-2.5-150 14 18 27 35 www.cfsfixings.com 5-4 Type FSA - Load Capacities for Slabs and Thick Walled Products Load capacity and installation dimensions for large-area precast elements or concrete beams Part No Permissible axial load kN Minimum thickness of precast unit Minimum Spacing Minimum thickness of beam c b 2xa Concrete strength in N/mm2 Concrete strength in N/mm2 15 mm 25 15 mm 25 35 mm CFS-FSA-0.7-110 7 145 390 280 70 70 70 CFS-FSA-1.4-110 14 145 390 380 110 80 70 CFS-FSA-2.0-130 20 165 460 460 150 110 90 CFS-FSA-2.0-160 20 195 660 660 120 80 80 CFS-FSA-2.5-150 25 185 530 530 180 130 100 CFS-FSA-2.5-200 25 235 730 700 130 90 70 CFS-FSA-3.0-160 30 195 560 560 210 150 120 CFS-FSA-3.0-220 30 255 700 700 160 120 100 CFS-FSA-4.0-180 40 215 630 630 280 200 160 CFS-FSA-4.0-240 40 275 840 840 200 140 110 CFS-FSA-5.0-180 50 215 630 630 380 270 220 CFS-FSA-5.0-240 50 275 840 840 270 190 150 CFS-FSA-7.5-260 75 300 910 910 420 300 240 CFS-FSA-7.5-300 75 340 1050 1050 360 250 200 CFS-FSA-10-300 100 340 1050 1050 540 380 300 CFS-FSA-10-370 100 410 1300 1300 420 300 240 CFS-FSA-14-370 140 410 1300 1300 700 500 400 CFS-FSA-14-460 140 500 1610 1610 530 380 300 CFS-FSA-22-500 220 540 1750 1750 900 640 520 CFS-FSA-22-620 220 660 2170 2170 700 500 400 TECHNICAL MANUAL – 2D SYSTEM Minimum edge distance = b/2 2D-VERSION 06-2013 If the lift is an angled pull β≥30° in a panel or wall, additional reinforcement will be required. Please also include the “Angled reinforcement as directed on page 6-7 forLARGE-AREA thin panels. PRECAST ELEMENTS OR CONCRETE BEAMS LOAD Pull” CAPACITY, INSTALLATION DIMENSIONS FOR When the load is towards the narrow edge, reinforcement for angled pull is necessary. Picture 34 Picture 33 Designation 5-5 Anchor length „L” www.cfsfixings.com Minimum Load thickness of range precast unit „c” Minimum spacing between centre „b” Table 15 Minimum thickness of beam „2 x a” fcu ≥ 15N/mm² fcu ≥ 25N/mm² fcu ≥ 35N/mm² fcu ≥ 15N/mm² fcu ≥ 25N/mm² fcu ≥ 35N/mm² [mm] [t] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 110 0,7 145 390 280 280 70 70 70 Load group 2,5t (0,7t – 2,5t) SA-B 0.7 T – 110 Type FSA - Load Capacities for Thin Walled Products TECHNICAL TECHNICAL TECHNICAL MANUAL MANUAL – MANUAL 2D –SYSTEM 2D SYSTEM – 2D SYSTEM 2D-VERSION 2D-VERSION 06-2013 2D-VERSION 06-2013 06-2013 Load capacity and installation dimensions for thin panels and walls LOADLOAD CAPACITY, CAPACITY, LOAD CAPACITY, INSTALLATION INSTALLATION INSTALLATION DIMENSIONS DIMENSIONS DIMENSIONS FOR FOR THIN-WALLED THIN-WALLED FOR THIN-WALLED PRECAST PRECAST ELEMENTS PRECAST ELEMENTS ELEMENTS Picture Picture 35 Picture 35 35 Picture Picture 36 Picture 36 36 With reinforcement With reinforcement With reinforcement tails placed tails placed as tails close placed as close to astoclose to Axial or angled load up toreinforcement β=30° Without Without reinforcement Without reinforcement tails tails tails Angled load 45° ≤ β ≤ 30° Picture Picture 37 Picture 37 37 the recess the recess former the recess former as possible former as possible as possible Table Table 16 16 Table For thin-walled precast elements, additional edge reinforcement and link reinforcement is required. For angled lift 16 Minimum thickness Minimum thickness of thickness precast of precast unit of precast unit unit Spacing Spacing SpacingMinimum 100% 100% F perm F100% perm 80%F Fperm 80% perm F perm 80% F perm where β > 30°, angled pull reinforcement bar is also used. The“2angled pull is insertedPull inAngled an opposite x a” “2 x a” “2 xreinforcement a” L between L between Lanchor between anchor anchor Pull Pull Angled pull Angled pull pull Designation Designation direction Designation to the load. The type of mesh is≥"determined by the permanent works engineer. centrecentre "present b " "centre b f"cu b " (β≤30°) (β≤30°) (β≤30°) (β>30°) (β>30°) (β>30°) 15N/mm² fcu≥ 15N/mm² fcu≥ f15N/mm² fcu≥ 25N/mm² fcu≥ f25N/mm² fcu≥ 35N/mm² fcu≥ 35N/mm² cu≥ 25N/mm² cu≥ 35N/mm² Lifting with Axial Pull [mm] [mm] [mm] [mm][mm] [mm][mm] [mm] [mm] [mm] [mm] [mm][mm] [mm] [mm] [kN] [kN] Load Load groupgroup 2,5t Load (0,7t 2,5t group –(0,7t 2,5t) 2,5t – 2,5t) (0,7t – 2,5t) Part No SA-B SA-B 0.7 T –0.7 SA-B 110 T – 0.7 110T – 110 110 110 160 160 SA-B SA-B 2.0T –2.0T SA-B 130 – 130 2.0T – 130 130 130 SA-B SA-B 2.0T –2.0T SA-B 160 – 160 2.0T – 160 160 160 SA-B SA-B 2.0T –2.0T SA-B 210 – 210 2.0T – 210 210 210 SA-B SA-B 2.5T –2.5T SA-B 150 – 150 2.5T – 150 150 150 kN 450 450 150 450 120 mm 120 120 90mm90 SA-B SA-B 2.5T –2.5T SA-B 200 – 200 2.5T – 200 CFS-FSA-0.7-110 SA-B SA-B 2.5T –2.5T SA-B 250 – 250 2.5T – 250 CFS-FSA-1.4-110 200 200 600 200 7 600 750 250 14 750 600 120 330 120 750 120 330 120 120 9070 90 120 9080 90 6090 80 6080 7090 80 7080 80 25 2 x 25 Ø6 x 400 80 25 2 x 25 Ø6 x 400 14 480 160 20 600 220 20 840 280 20 540 180 25 720 240 25 960 320 480 480 160 390 160 600 120 120 480 840 120 120 630 540 210 210 450 720 150 150 600 960 150 150 80 160 100 110100 70 100 90 100 90 100 90 130 90 120 90 120 2 x Ø6 x 400 90 30 2 x 30 Ø6 x 500 90 30 30 2 x Ø6 x 500 90 30 30 2 x Ø6 x 500 100 40 40 2 x Ø8 x 600 100 40 40 2 x 40 Ø8 x 600 100 40 250 250 Load Load groupgroup 5t Load (3,0t-5,0t) 5t group (3,0t-5,0t) 5t (3,0t-5,0t) CFS-FSA-1.4-160 SA-B SA-B 3.0T – 3.0T SA-B 160 – 160 3.0T – 160 160 160 CFS-FSA-2.0-130 SA-B SA-B 3.0T –3.0T SA-B 220 – 220 3.0T – 220 CFS-FSA-2.0-160 SA-B SA-B 3.0T –3.0T SA-B 280 – 280 3.0T – 280 CFS-FSA-2.0-210 SA-B SA-B 4.0T –4.0T SA-B 180 – 180 4.0T – 180 CFS-FSA-2.5-150 SA-B SA-B 4.0T –4.0T SA-B 240 – 240 4.0T – 240 CFS-FSA-2.5-200 SA-B SA-B 4.0T –4.0T SA-B 320 – 320 4.0T – 320 CFS-FSA-2.5-250 SA-B SA-B 5.0T –5.0T SA-B 180 – 180 5.0T – 180 CFS-FSA-3.0-160 SA-B SA-B 5.0T –5.0T SA-B 240 – 240 5.0T – 240 CFS-FSA-3.0-220 SA-B SA-B 5.0T –5.0T SA-B 400 – 400 5.0T – 400 220 220 280 280 180 180 240 240 320 320 480 600 840 540 720 960 240 240 25 540 540 180 30 720 720 240 400 400 30 1200 1200 400 180 180 CFS-FSA-3.0-280 Load Load groupgroup 10t Load (5,3t-10t) 10t group (5,3t-10t) 10t (5,3t-10t) 30 540 350 750 350 720 180 480 180 1200180 600 180 840 120 100 100 110 120 100 100 110 210 130 130 120 150 120 120 120 150 120 120 90 80 80 70 90 8090 90 90 80 90 90 80 100 100 80 100 100 80 100 100 120210 350 210 160150 180 150 90 210 150 80 150 100 150 120 90120 120150 180 150 100 150 120 90120 120 100 90 Link reinforcement 60 7,0 7,0 7,05,6 nxØxL 70 14 14 14 11,2 [kN] Edge 5,6 5,6 reinforcement 11,2 11,2 70 14 mm20 80 14 20 14 11,2 11,2 2016 mm 16 80 20 20 2016 16 16 80 20 20 2016 16 16 80 25 25 2520 20 20 2520 Ø206 Ø206 20 2 x 50 Ø8 x 600 150 50 2 x 50 Ø8 x 700 120 50 2 x 50 Ø8 x 700 120 50 2520 3024 3024 3024 4032 4032 4032 Ø6 Ø246 24 Ø6 24 Ø6 32 Ø8 32 Ø328 5040 Ø408 Ø408 5040 Ø408 5040 2 x Ø8 x 700 Ø8 11,2 16 20 24 24 24 32 32 32 40 40 40 CFS-FSA-4.0-180 SA-B SA-B 5.3T –5.3T SA-B 220 – 220 5.3T – 220 220 220 40 660 660 220 660 350 540 350 210210 350 210 130 210 150 100 150 2 x 53 Ø8 x 800 150 53 Ø8 53 42,4 42,4 42,4 SA-B SA-B 5.3T –5.3T SA-B 260 – 260 5.3T – 260 CFS-FSA-4.0-240 SA-B SA-B 5.3T – 5.3T SA-B 340 – 340 5.3T – 340 CFS-FSA-4.0-320 260 260 780 260 40 780 1020 340 40 1020 780 180 720 180 1020180 960 180 180 150 150150 150 120 100 120 120 150 120 120 120 100 200 150 150 150 210 120 53 2 x 53 Ø8 x 800 120 53 53 2 x Ø8 x 800 53 42,4 42,4 Ø8 53 42,4 42,4 Ø8 42,4 SA-B SA-B 7.5T –7.5T SA-B 260 – 260 7.5T – 260 CFS-FSA-5.0-180 SA-B SA-B 7.5T –7.5T SA-B 300 – 300 7.5T – 300 CFS-FSA-5.0-240 SA-B SA-B 7.5T –7.5T SA-B 420 – 420 7.5T – 420 CFS-FSA-5.0-400 SA-B SA-B 10.0T 10.0T SA-B – 300 –10.0T 300 – 300 CFS-FSA-7.5-260 SA-B SA-B 10.0T 10.0T SA-B – 370 –10.0T 370 – 370 CFS-FSA-7.5-300 SA-B SA-B 10.0T 10.0T SA-B – 520 –10.0T 520 – 520 340 340 260 260 300 300 420 420 300 300 370 370 520 520 CFS-FSA-7.5-420 Load Load groupgroup 26t Load (12,5t-26t) 26t group (12,5t-26t) 26t (12,5t-26t) CFS-FSA-10-300 SA-B SA-B 14.0T 14.0T SA-B – 370 –14.0T 370 – 370 370 370 CFS-FSA-10-370 SA-B SA-B 14.0T 14.0T SA-B – 460 –14.0T 460 – 460 460 460 CFS-FSA-10-520 SA-B SA-B 22.0T 22.0T SA-B – 500 –22.0T 500 – 500 500 500 SA-B SA-B 22.0T 22.0T SA-B – 620 –22.0T 620 – 620 620 620 CFS-FSA-14-370 780 260 50 900 300 50 1260 420 50 900 300 75 1110 370 75 1560 520 1560 780 340 540 340 900 240 240 720 1260200 200 1200 900 450 450 780 1110270 270 1560250 900 250 100 1110 1110 370 100 1380 460 1380 1110610 900 610 1380350 1110 350 450360 610 360 270 350 210 210 100 1500 1500 500 1500760 1560 760 1860 620 140 1860 1860450 1110 450 75 CFS-FSA-14-460 alterations alterations reserved alterations reserved reserved CFS-FSA-22-500 140 220 CFS-FSA-22-620 220 780 180 150 150150 900 1260 900 1110 1260 340 200 350200 240 160 160 180 200 160 160 180 450 270 270 340 270 190 190 240 250 190 190 200 160 150 160 150 270 200 190 160 190 160 140 140 120 140 140 120 190 190 150 160 160 140 160 160 140 150 2 x 75 Ø10 x75 800 140 75 75 2 x Ø10 x 800 140 75 75 2 x Ø10 x 800 190100 100 4 x Ø10 x 800 160100 100 4 Ø10 x100 800 160x100 4 x Ø10 x 800 7560 7560 7560 10080 10080 10080 42,4 Ø6010 60 Ø 10 60 Ø 10 80 Ø 10 80 Ø8010 60 Ø 10 60 60 80 80 80 6 x140 Ø10 x140 1000 140 260 112 6 x Ø10 x 1000 170140 140 140 112 6 x220 Ø10 x220 1000 220 340 176 Ø 12 112 Ø 12 112 Ø 12 176 112 250460 760 460 270 360 260 190 260 190 210 170 160 170 190 460 340 160 340 450 280 610280 280 240 260 240 360 240 176 Ø 176 6 x220 Ø10 x220 1000 220 16 176 1380 350 210 460 1860 450 280 10/29/2013 10/29/2013 1500 10/29/2013 760 170 QUICK LIFT ANCHORS SA-B SA-B 1.4 T -1.4 SA-B 160 T - 160 1.4 T - 160 Permissible Minimum Minimum thickness of 330 110 330 330 70 70 70 60 60 60 60 60 axial load Spacing unit 330 110 330 330 80 80 80 70 70 70 70 70 b 2xa 480 160 480 480 80 80 80 70 70 70 70 70 strength 390 130 390 390 110 110 110 90Concrete 90 90 80 80 in N/mm2 480 160 480 480 110 110 110 90 90 90 80 80 2590 80 3580 630 210 630 630 110 110 110 9015 90 SA-B SA-B 1.4 T –1.4 SA-B 110 T – 1.4 110T – 110 110 110 [kN] [kN] [kN] 112 176 6 x Ø10 x 1000 Ø 16 340 19Ø 1619 Page 19 8 x Ø10 x 1200 PagePage 240 8 x Ø10 x 1200 Ø 16 Minimum edge distance = b/2 Please see next page for arrangement of additional reinforcement and also angled pull capacities. www.cfsfixings.com 5-6 Type FSA - Load Capacities for Thin Walled Products Lifting with Angled Pull Part No Permissible axial load Minimum Spacing Minimum thickness of unit 2a b Concrete strength in N/mm2 15 25 Link reinforcement Edge reinforcement Angled pull reinforcement Ø x Ls mm mm mm 35 kN mm CFS-FSA-0.7-110 5.6 330 mm 70 60 60 4 x Ø6 x 400 Ø8 Ø 6 x 450 CFS-FSA-1.4-110 11.2 330 80 70 70 4 x Ø6 x 400 Ø8 Ø 6 x 900 CFS-FSA-1.4-160 11.2 480 80 70 70 4 x Ø6 x 400 Ø8 Ø 6 x 900 CFS-FSA-2.0-130 16 390 110 90 80 4 x Ø6 x 500 Ø8 Ø 8 x 950 CFS-FSA-2.0-160 16 480 110 90 80 4 x Ø6 x 500 Ø8 Ø 8 x 950 CFS-FSA-2.0-210 16 630 110 90 80 4 x Ø6 x 500 Ø8 Ø 8 x 950 CFS-FSA-2.5-150 20 450 120 90 80 4 x Ø8 x 600 Ø 10 Ø 8 x 1200 CFS-FSA-2.5-200 20 600 120 90 80 4 x Ø8 x 600 Ø 10 Ø 8 x 1200 CFS-FSA-2.5-250 20 750 120 90 80 4 x Ø8 x 600 Ø 10 Ø 8 x 1200 CFS-FSA-3.0-160 24 480 160 100 90 4 x Ø8 x 700 Ø 10 Ø 10 x 1150 CFS-FSA-3.0-220 24 600 120 100 90 4 x Ø8 x 700 Ø 10 Ø 10 x 1150 CFS-FSA-3.0-280 24 840 120 100 90 4 x Ø8 x 700 Ø 10 Ø 10 x 1150 CFS-FSA-4.0-180 32 540 210 130 100 4 x Ø8 x 800 Ø 12 Ø 10 x 1500 CFS-FSA-4.0-240 32 720 150 120 100 4 x Ø8 x 800 Ø 12 Ø 10 x 1500 CFS-FSA-4.0-320 32 960 150 120 100 4 x Ø8 x 800 Ø 12 Ø 10 x 1500 CFS-FSA-5.0-180 40 540 350 210 150 4 x Ø10 x 800 Ø 12 Ø 12 x 1550 CFS-FSA-5.0-240 40 720 180 150 120 4 x Ø10 x 800 Ø 12 Ø 12 x 1550 CFS-FSA-5.0-400 40 1200 180 150 120 4 x Ø10 x 800 Ø 12 Ø 12 x 1550 CFS-FSA-7.5-260 60 780 340 200 150 4 x Ø10 x 800 Ø 12 Ø 16 x 2000 CFS-FSA-7.5-300 60 900 240 160 140 4 x Ø10 x 800 CFS-FSA-7.5-420 60 1260 200 160 140 4 x Ø10 x 800 Ø 12 Ø 16 x 2000 TECHNICAL MANUAL – 2D SYSTEM Ø 12 Ø 16 x 2000 CFS-FSA-10-300 80 900 450 270 190 6 x Ø10 x 1000 CFS-FSA-10-370 80 2D-VERSION 06-2013 Ø 16 Ø 16 x 2300 1110 AT ANCHOR 270 ZONE 190 160 6 x Ø10ELEMENTS x 1000 Ø 16 REINFORCEMENT TYPES FOR THIN-WALLED PRECAST 1560 250 190 160 6 x Ø10 x 1000 Ø 16 Ø 16 x 2300 CFS-FSA-10-520 80 CFS-FSA-14-370 112 1110 610 360 260 CFS-FSA-14-460 112 1380 350 210 MANUAL SYSTEM 170 TECHNICAL 8 x Ø10 x 1000 – 2D Ø 16 CFS-FSA-22-500 176 1500 760 CFS-FSA-22-620 176 1860 450 8 x Ø10 x 1000 Ø 16 x 2300 Ø 16 Ø 20 x 2600 Ø 20 x 2600 460 340 x Ø10 x 12002D-VERSION Ø 16 06-2013 TECHNICAL MANUAL – 2D8 SYSTEM 280 240 2D-VERSION 8 x Ø10 x 1200 06-2013 Ø 28 x 3550 Ø 16 Ø 28 x 3550 REINFORCEMENT TYPES AT ANCHOR ZONE FOR THIN-WALLED PRECAST ELEMENTS Minimum edge distance = b/2 EINFORCEMENT TYPES AT ANCHOR ZONE FOR THIN-WALLED PRECAST ELEMENTS Link and Edge Reinforcement Angled Pull Reinforcement Applied load Angled pull reinforcement is inserted in the opposite direction to the load. Picture 39 SR L Picture 38 Required for angled pull ≥30° panel edge reinforcement placed alongside the anchor Angled pull reinforcement SR = over all length = 2× leg length Picture 38 Picture 38 is inserted in the opposite direction to the load. in the 39 T ypical additionaAngled l links as tpull able treinforcement o be used over a zis oneinsertedPicture opposite direction to the load. of 3× the anchor length. Picture 39 Ls (overall length) = 2 x length of leg The edge and link reinforcement should be installed on both sides of the anchor in an area equal to 3 x length of the 40 be installed as close as possible to the recess Picture 41 anchor. The two links in the vicinity of the anchor Picture should former. Concrete strength fcu ≥ 15 N / mm² Table 17 Pull (β≤30°) 5-7 www.cfsfixings.com Designation Load group 2,5t (0,7t – 2,5t) Load range Slot-in-link [t] [mm] nxØxL Angled pull (β>30°) Edge reinforcement [mm] Slot-in-link nxØxL [mm] Edge reinforcement [mm] Ls (overall length) = 2 x length of leg Angled pull reinforcement Ø x Ls [mm] Type FTH - Two Hole Anchor The lifting anchor is made of St 52-3 steel. The stress transfer to the concrete occurs through the reinforcement bar. a c b d Part No Load Group Dimensions a b c d mm CFS-FTH-07-90 0.7 30 90 5 14 CFS-FTH-14-90 1.4 30 90 6 14 2 30 90 8 14 2.5 30 90 10 14 CFS-FTH-30-120 3 40 120 10 18 CFS-FTH-40-120 4 40 120 12 18 CFS-FTH-50-120 5 40 120 15 18 CFS-FTH-75-160 7.5 60 160 15 26 CFS-FTH-100-170 10 60 170 20 27 CFS-FTH-140-240 14 80 240 20 35 CFS-FTH-220-300 22 80 300 25 35 www.cfsfixings.com QUICK LIFT ANCHORS CFS-FTH-20-90 CFS-FTH-25-90 5-8 TECHNICAL MANUAL – 2D SYSTEM 2D-VERSION 06-2013 TECHNICAL MANUAL – 2D SYSTEM Type FTH - Load Capacity and Additional Reinforcement Requirements 2D-VERSION 06-2013 LOAD CAPACITY, INSTALLATION DIMENSIONS LOAD CAPACITY, INSTALLATION DIMENSIONS FOR LARGE-AREA PRECAST ELEMENTS OR CONCRETE BEAMS Picture 47 Part No Picture 48 Minimum Spacing Without reinforcement tails b mm CFS-FTH-07-90 400 Designation 500 Designation CFS-FTH-14-90 600 CFS-FTH-25-90 600 [mm] [mm] 100 0,7 750 110 110 90 110 SA-ST 1.4T SA-B– 90 2.0T – 130 CFS-FTH-75-160 1200 SA-ST 2.0T – 90 CFS-FTH-100-170 1200 SA-B 2.0T – 160 90 130 130 90 140 160 2,0 SA-ST 2.5T CFS-FTH-140-240 1500 SA-B– 90 2.5T – 150 90 160 150 2,5 CFS-FTH-220-300 1500 Load group 5t (3,0t-5,0t) SA-B 2.5T - 200 180 200 2,5 SA-ST 3.0T – group 120 5t (3,0t-5,0t) Load 120 SA-B– 120 3.0T – 160 SA-ST 4.0T 160 3,0 120 thickness of Part No Minimum Spacing b 90 100 120 1,4 2,0 30 145 400 145 50 500 165 Angled lift, 45° ≤ β ≤ 30° 700 195 Permissible axial mm 240 160 80 180 160 4,0 kN 800 275 5.6 5,0 1200 215 CFS-FTH-20-90 600 Load group 10t (5,3t-10t) CFS-FTH-25-90 600 Load group 26t (12,5t-26t) SA-B 5.3T – 220 CFS-FTH-30-120 650 SA-ST 14.0T – 240 SA-B 5.3T – 260 CFS-FTH-40-120 700 SA-ST 22.0T – 300 CFS-FTH-50-120 750 SA-B 7.5T – 260 SA-ST 26.0T – 300 CFS-FTH-75-160 1200 SA-B 7.5T – 300 80 240 170 90 SA-B 10.0T – 300 300 10 340 SA-B 10.0T – 370 370 10 1200 CFS-FTH-140-240 1500 CFS-FTH-220-300 1500 140 80 110 14 460 2 x Ø10 x 800 150 20 4660 x Ø10 x 800 120 25 4530 x Ø10 x 1000 180 4 x Ø12 x 1200 700 560 40 630 630 630 mm 840 340 Ø8 4 x Ø8 x 600 Ø 10 840 1 x Ø25 x 1850 6 x Ø10 x 1000 1050 1050 1300 1300 1300 SA-B edge 14.0Tdistance – 370 14 410 1300 1300 Minimum = b/2 370 2 Concrete strength assumed to be 15N/mm SA-B 14.0T – 460 460 14 500 1610 1610 The type mesh–present is determined by the engineer. 1750 SA-Bof 22.0T 500 500 22 permanent 540 works1750 1300 Load group 26t (12,5t-26t) alterations reserved SA-B 22.0T – 620 alterations reserved www.cfsfixings.com 180 620 22 112 176 1 x Ø32 x 2350 410 1 x Ø32 x 3000 10/29/2013 660 280 mm 4 x Ø6 x 500 100 840 1050 160 210 140 1 x Ø12 x 800 4 x Ø6 x 400 2170 10/29/2013 Ø8 Ø8 200 380 270 70 90 Ø 121680 Ø 1620130 Ø 16 80 100 90 70 Ø 12 240 Ø 12 420 Ø 12 360 Ø 12 32150 120 200 160 Angled pull 120 100 40 reinforcement Ø x Ls mm 140 42,4 Ø6 x 900 60270 110 220 Ø6 x 900 190 80 Ø8 x 950 150 Ø8 x 1200 Ø 10 280 Ø16 x 2300 160 140 240 200 300 300 240 700 500 400 1610 530 380 300 1750 900 640 520 2170 700 Ø 16 8 x Ø10 x 1200 Ø 16 540 200x 1150 Ø10 112 180x 1500 Ø10 176 Ø12 300x 1550 208 Ø16 250x 2000 380 8 x Ø10 x 1000 2170 70 Ø 10 Edge 160 reinforcement 1 x Ø10 x 650 770 4 x Ø8 x 700 770 160 140 1 x880 Ø16 x 1200 880 4 x Ø8 x 800 880 180 220 1 x910 Ø16 x 1500 910 4 x Ø10 x 800910 200 260 1 1050 x Ø20 x 1750 1050 4 x Ø10 x 8001050 300 70 5,680 Ø8 11,2 110 Ø8 24 840 53 4 x Ø6 x 400 630 630 75 1 x770 Ø16 x 1000 300 130 Ø8 30 560 1 x Ø12 x 1000 260 70 2 x Ø8 x 800 560110 840 20 5,3 24 1500 5,3 32 1500 7,5 40 1500 7,5 60 280 7,0 380 Reinforcement Link reinforcement 700 700 50 tail n 120 x Ø x La 700 nxØxL 840120 1 x Ø10 x 650 630130 5,0 1200 275 16 100 100 mm 11.2 220 100 240 260 110 300 120 260 300 130 300 CFS-FTH-100-170 3000 730 1 x Ø28 x700 235 2xa 180 SA-B– 160 5.0T – 180 SA-ST 7.5T CFS-FTH-14-90 500 SA-B – 5.0T SA-ST 10.0T 170 – 240 1 x Ø28 x530 2350 530100 220 SA-B – 180 Load group 10t 4.0T (5,3t-10t) mm SA-B 4.0T SA-ST 5.3T – 160 – 240 2 x Ø8 x 700 280 1 x Ø16 x380 1500 75 3,0 load 750 255 4,0 215 2 x Ø8 x 700 1 x Ø16 x 1200 460 80 1 x Ø20 x460 1750 90 1850 660 1 x Ø25 x660 650 Minimum 1 x Ø16 x 1000 390 80 600 100 195 600 140 185 beam 220 120 400 390 40 SA-B– 120 3.0T – 220 SA-ST 5.0T CFS-FTH-07-90 Table 15 Minimum spacing mm Minimum kN mm mmthickness of beam Minimum between centre „b” „2 xTable a” 21 Load thickness of 7 1 x Ø10 x 650 2 x Ø6 x 400 Ø6 Minimum spacing thickness 100% F perm 80% F perm range precast unit Minimum fcu ≥ f ≥ fcu ≥ f ≥ f ≥ fcu ≥ 14„c” 1 x Ø10 x cu 650 2Pull x Ø6 x 400 cu Ø 6 cupull between centre of precast unit 15N/mm² 25N/mm² 35N/mm² 15N/mm²Angled 25N/mm² 35N/mm² "b" 20 "2 x1 a" (β≤30°) (β>30°) x Ø12 x 800 2 x Ø6 x 500 Ø6 [t] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]25 [mm] 1 x Ø12 x 1000 2[kN] x Ø8 x 600 Ø 6[kN] CFS-FTH-20-90 CFS-FTH-50-120 5-9 mm Anchor 80 length „L” L80 Load group 2,5t (0,7t – 2,5t) CFS-FTH-30-120 Load group 2,5t (0,7t – 650 2,5t) SA-B 0.7 T – 110 CFS-FTH-40-120 700 SA-ST 0.7T SA-B– 90 1.4 T – 110 Picture 49 When the load is towards the narrow edge, Minimum thickness Axial and angled lift, β ≤ 30° reinforcement for angled pull is necessary. With reinforcement tails placed as close to of beam Permissible Reinforcement tail Link reinforcement Picture 33 the recess Picture 34 Edge former axial as possible load n x Ø x La nxØxL reinforcement 2xa 420 Ø20 x 2600 Ø25 x 3000 Page 23 500 400 Page 18 Two Hole Anchor Load Capacity and Additional Reinforcement Requirements TECHNICAL MANUAL – 2D SYSTEM 2D-VERSION 06-2013 REINFORCEMENT TYPE USED IN ANCHOR ZONE TECHNICAL MANUAL – 2D SYSTEM 2D-VERSION 06-2013 REINFORCEMENT TYPES AT ANCHOR ZONE FOR THIN-WALLED PRECAST ELEMENTS TECHNICAL MANUAL – 2D SYSTEM La = overall length. 2D-VERSION 06-2013 The bending angle must be ≤ 30 ° TECHNICAL MANUAL – 2D SYSTEM 2D-VERSION 06-2013 Picture 50 Picture 51 REINFORCEMENT TYPES AT ANCHOR ZONE FOR THIN-WALLED PRECAST ELEMENTS Reinforcement tail Link and Edge Reinforcement Angled Pull Reinforcement Applied load Angled pull reinforcement is inserted in the opposite direction to the load. Picture 39 SR Picture 38 L Picture 52 SR = over all length = 2× leg length Picture 38 Load of 3× the anchor length. =the overall length. aDesignation range The endsLof bar may be straight The bending angle must be ≤ 30 ° instead of turned in. Picture Load group 2,5t (0,7t – 2,5t) in the opposite direction to the load. Table 22 Picture 39 T ypical additional links as table to be used over a zone [t] 51 Required for angled pull ≥30° Pull (β≤30°) Slot-in-link nxØxL Edge reinforcement [mm] [mm] Reinforcement tail n x Ø x La [mm] QUICK LIFT ANCHORS panel edge reinforcement Ls (overall length) = 2 x length of leg placed alongside Angled pull is inserted the anchorreinforcement Picture 53 Ls (overall length) = 2 x length of leg The SA-ST Picture edge should be2 installed on40both sidesØof6 the anchor in1 an area to 3 41 x length of the 1.4 T and link reinforcement1,4 x Ø 6 x 400 x Ø10 x 650equalPicture Concrete strength fcu ≥ 15 N / mm² anchor. The two links in the vicinity of the anchor should be installed as close as possible to the recess former. Table 17 SA-ST 2.0T 2,0 2 x Ø 6 x 500 Ø6 1 x Ø12 x 800 Pull (β≤30°) Angled pull (β>30°) SA-ST 2.5T 2,5 Load group 5t (3,0t-5,0t) Designation 2 x Ø 8 x 600 Load range 3,0 2 x Ø 8 x 700 [t] SA-ST 3.0T SA-ST 4.0T 2 x Ø 8 x 700 Load group4,0 2,5t (0,7t – 2,5t) SA-ST 5.0T SA-B 0.7 T5,0 2 x Ø 8 x 800 0,7 Picture 40 SA-B 1.4 T Load group 10t (5,3t-10t) 1,4 Concrete strength fcu ≥ 15 N / mm² SA-ST 5.3T SA-ST 7.5T SA-ST 10.0T nxØxL Edge reinforcement Ø8 [mm] [mm] 1Slot-in-link x Ø12 x1000 nxØxL 1 x [mm] Ø14 x1000 [mm] group 2,5t (0,7t – 2,5t) SA-B 5.0T 14 SA-ST Load 14.0T 4 x Ø10 x1000 5,0 Ls (overall length) = 2 x length of leg SA-B 0,722 2 x Ø 64 xx 400 SA-ST 22.0T0.7 T Ø12 x1200 Load group 10t (5,3t-10t) [mm] Ø 6 x 450 Ø 6 x 900 Ø6 Picture 41x 400 4xØ6 Ø8 Table 17 2 x Ø10 x 800 Ø14 Ø6 Ø10 4 Ø14 x Ø 6 x 300 Ø28x x2350 41xxØ10 800 Ø12 Ø 8 x 950 Ø 8 x 1200 Ø10 x 1150 Ø10 x 1500 Ø12 x 1550 Ø18x Ø28 x3000 Ø 6 x 450 2 x Ø 6 x 400 Ø6 4 x Ø 6 x 400 2 x Ø10 x 800 Ø10 Ø 4 x8 Ø10 x 800 Ø 6 x 900 Ø12 Ø12 x 1650 2,0 SA-B 7.5T 2 x Ø 6 x 500 7,5 Ø6 4 x Ø 6 x 500 4 x Ø10 x 800 Ø10 Ø 4 x8 Ø10 x 800 Ø 8 x 950 Ø12 Ø14 x 2000 SA-B 2.5T SA-B 10.0T 2,5 2 x Ø 8 x 600 10 Ø12 Ø 68 x Ø10 x1000 4 x Ø 8 x 600 6 x Ø10 x1000 Ø 8 x 1200 Ø14 Ø10 Ø16 x 2300 Load group 5t (3,0t-5,0t) Load group 26t (12,5t-26t) 2 x Ø 8 x 700 14 Ø14 Ø 68 x Ø10 x1000 4 x Ø 8 x 700 8 x Ø10 x1000 Ø10 x 1150 Ø14 Ø10 Ø20 x 2600 2 x Ø 8 x 800 22 Ø14 Ø 88 x Ø10 x1200 4 x Ø 8 x 800 8 x Ø10 x1200 Ø10 x 1500 Ø16 Ø12 Ø28 x 3550 Ø10 4 10/29/2013 x Ø10 x 800 Ø12 Ø12 x 1550 SA-B 2.0T 53 Pull (β≤30°) Edge SA-B 3.0T reinforcement SA-B 4.0T SA-B 5.0T 10/29/20135,3 Table 22 Reinforcement tail SA-B 14.0T 3,0 n x Ø x La SA-B 22.0T 4,0 [mm] Load group 10t (5,3t-10t) 5,0 2 x Ø10 x 800 alterations reserved Page 24 Ø 6 SA-B 5.3T 1 x Ø10 x 6505,3 2 x Ø10 x 800 Ø10 4 x Ø10 x 800 Ø12 Ø12 x 1650 SA-B 7.5T 7,5 4 x Ø10 x 800 Ø10 4 x Ø10 x 800 Ø12 Ø14 x 2000 10 6 x Ø10 x1000 Ø12 6 x Ø10 x1000 Ø14 Ø6 Ø x Ls 1,4 SA-B 5.3T alterations reserved Picture Ø6 Angled pull reinforcement 2 x Ø 6 x 400 2,0 2 x Ø 6 x 500 Ø6 4 x Ø 6 x 500 Ø8 5,3 2 x Pull Ø 8 x(β≤30°) 800 Ø8 1 x (β>30°) Ø16 x1750 Angled pull SA-B 2.5T 2,5 2 x Ø 8 x 600 Ø 8 4 x Ø 8 x 600 Ø10 Load Slot-in-link Slot-in-link 7,5 2 x Ø10 x 800 Ø10 1 x Ø20 x1750Angled pull Edge Edge reinforcement range Load group 5t (3,0t-5,0t) reinforcement reinforcement 10 4 x Ø10 x 800 Ø12 1 x Ø25 x1850 nxØxL Ø x LØ10 s SA-B 3.0T 3,0 2 x Ø 8 x 700 n x Ø x LØ 8 4 x Ø 8 x 700 [mm] [mm] [mm]Ø12 SA-B 4.0T[t] 4,0 [mm] 2 x Ø 8 x 800 [mm] Ø 8 4 x Ø 8 x 800 Designation SA-B 1.4 T Edge reinforcement Ø 8 Ls (overall length) 1 x=Ø16 2 x x1200 length of leg 2 x Ø 6 x 400 Ø 8 Ø6 41xxØØ16 6 x x1500 300 Ø8 SA-B 2.0T Load group 26t (12.5t-26t) [mm] Slot-in-link Ø 6 SA-B 10.0T 1 x Ø12 x 800 1 x Ø12 x1000 Page 20 Ø16 x 2300 www.cfsfixings.com Load group 26t (12,5t-26t) SA-B 14.0T 14 6 x Ø10 x1000 Ø14 8 x Ø10 x1000 Ø14 Ø20 x 2600 Ø 8 SA-B 22.0T 1 x Ø14 x100022 8 x Ø10 x1200 Ø14 8 x Ø10 x1200 Ø16 Ø28 x 3550 5-10 Type FE - Tilting Anchor The lifting anchor is made of St 52-3 steel and is used for erecting and turning thin walled precast units in both directions. The stress transfer to the concrete occurs through the reinforcement bar, which is laid over both sides of the anchor. a c d b Part No Load Group Dimensions a b c d mm 5-11 CFS-FE-14-200 1.4 55 200 6 14 CFS-FE-25-150 2.5 55 150 10 14 CFS-FE-25-230 2.5 55 230 10 14 CFS-FE-40-270 4 70 270 12 18 CFS-FE-50-290 5 70 290 15 18 CFS-FE-75-320 7.5 95 320 18 26 CFS-FE-100-390 10 95 390 20 26 www.cfsfixings.com TECHNICAL MANUAL – 2D SYSTEM Tilting Anchor Load Capacity and Additional Reinforcement Requirements 2D-VERSION 06-2013 LOAD CAPACITY, INSTALLATION DIMENSIONS TECHNICAL MANUAL – 2D SYSTEM 2D-VERSION 06-2013 LOAD CAPACITY, INSTALLATION DIMENSIONS Picture 65 Part No Picture 66 Minimum Spacing Picture 67 Load Capacities Additional Reinforcement without tail reinforcement Axial or angled load 45>β≤30° Angled load β>30° Tilting load Erecting and pitching reinforcement b 2xa mm mm kN kN kN mm CFS-FE-14-200 700 100 14 11.2 7 Ø 10 x 700 CFS-FE-25-150 550 120 25 20 12.5 Ø 12 x 800 CFS-FE-25-230 800 120 25 20 12.5 Ø 12 x 800 CFS-FE-40-270 950 150 40 32 20 Ø 16 x 1000 CFS-FE-50-290 1000 160 50 40 25 Ø 16 x 1000 CFS-FE-75-320 1200 250 75 60 37.5 Ø 20 x 1200 CFS-FE-100-390 1500 Picture 300 68 100 80 50 Picture 69 Ø 20 x 1500 Erecting and pitching reinforcement QUICK LIFT ANCHORS Minimum thickness of beam Reinforcement tail for lifting Minimum edge distance = b/2 2 Concrete assumed be 15N/mm La = overall length. Picture 65 to The Picture 66 Picture 67 Lv =strength length before bending. height of bend depend on the element thickness (2 by x a)the permanent works engineer.The bending angle must be ≤ 30° The type of mesh present is determined Erecting and Pitching Reinforcement Load group Load group 1,25t - 1,5t Table 31 Erecting and pitching reinforcement Ø x Lv Load range Reinforcement tail Ø x La [t] [mm] [mm] 1,25 – 1,5 Ø 8 x 600 Ø 8 x 700 1,4 Ø10 x 700 Ø10 x 650 2,5 Ø12 x 800 Ø12 x 1000 4,0 Ø14 x 950 Ø16 x 1200 5,0 Ø16 x 1000 Ø16 x 1500 7,5 each Ø20 x 1200 Load group 2,5t (0,7t – 2,5t) Load group 5t (3,0t-5,0t) 2 No Load erecting pitching bars required for Picture 68 groupand 10t (5,3t-10t) anchor 10,0 and pitching reinforcement Lv = length beforeErecting bending The height of the bend depends on the element thickness Ø20 x 1750 Picture 69 Ø20 x 1500 Ø20 x 1900 Reinforcement tail for lifting La = overall length. Lv = length before bending. The height of bend depend on the alterations reserved 10/29/2013 Page 28 element thickness (2 xas a)the erecting and pitching reinforcement The bendingprovides angle must beresistance ≤ 30° No angled pull reinforcement is required the required. Load group Load group 1,25t - 1,5t Load group 2,5t (0,7t – 2,5t) Load range Erecting and pitching reinforcement Ø x Lv Table 31 Reinforcement tail Ø x La [t] [mm] 1,25 – 1,5 Ø 8 x 600 [mm] 1,4 Ø10 x 700 Ø10 x 650 2,5 Ø12 x 800 Ø12 x 1000 www.cfsfixings.com Ø 8 x 700 5-12 Type FFA - Flat Foot Anchor The lifting anchor is made of St 52-3 steel. The stress transfer to the concrete occurs through the reinforcement bar, which is laid over the spread foot. c a d b w Part No Load Group Dimensions a b c d w mm CFS-FFA-07-065 0.7 30 65 5 14 100 CFS-FFA-14-068 1.4 30 68 6 14 100 CFS-FFA-20-070 2 30 70 8 14 100 CFS-FFA-25-075 2.5 30 75 10 14 100 CFS-FFA-30-090 3 40 90 10 18 120 CFS-FFA-40-110 4 40 110 12 18 120 CFS-FFA-50-125 5 40 125 15 18 120 4–1 5-13 www.cfsfixings.com SA-FA 2.5T – 75 45928 45929 75 30 10 100 2,5 0,230 SA-FA 3.0T – 90 45930 SA-FA 4.0T – 110 45932 45931 90 40 10 120 3,0 0,380 45933 110 40 12 120 4,0 0,520 SA-FA 5.0T – 125 45934 45935 125 40 15 120 5,0 0,705 Load group 5t (3,0t-5,0t) Type FFA - Capacity and Additional Reinforcement Requirements REINFORCEMENTS TYPE USED IN ANCHOR ZONE Picture 73 Note: Part No Minimum thickness Minimum Spacing as Permitted Reinforcement tails placed as close to the anchor possible.load of precast unit Picture 74 Reinforcement bars Axial, angled and transverse pull Ø L c alterations reserved 10/29/2013 Page 30 b 15 25 mm mm kN CFS-FFA-07-065 80 280 7 7 8 200 CFS-FFA-14-068 80 280 14 14 8 250 CFS-FFA-20-070 90 300 18 20 8 300 CFS-FFA-25-075 100 320 20 25 8 300 CFS-FFA-30-090 120 380 28 30 10 400 CFS-FFA-40-110 140 460 37 40 12 450 CFS-FFA-50-125 160 520 44 50 12 500 mm QUICK LIFT ANCHORS Concrete strength in N/mm2 Minimum edge distance = b/2 1 1 2 2 1 3 3 1 www.cfsfixings.com 5-14 Type FPA - Plate Anchor The lifting anchor is made of St 52-3 steel. The stress transfer to the concrete occurs through the reinforcement bar, which is laid over the plate crosswise. a c b d c Part No 5-15 Load Group Dimensions a b c d mm mm mm mm CFS-FPA-14-50 1.4 30 50 80 8 CFS-FPA-25-80 2.5 30 80 100 8 CFS-FPA-50-120 5 40 120 100 10 CFS-FPA-100-160 10 60 160 100 12 www.cfsfixings.com SA-FA 2.5T – 75 45928 45929 75 30 10 100 2,5 0,230 SA-FA 3.0T – 90 45930 SA-FA 4.0T – 110 45932 45931 90 40 10 120 3,0 0,380 45933 110 40 12 120 4,0 0,520 5,0 0,705 Load group 5t (3,0t-5,0t) Flat Plate Anchor Capacity and Additional Reinforcement Requirements SA-FA 5.0T – 125 45934 45935 125 40 REINFORCEMENTS TYPE USED IN ANCHOR ZONE 15 120 Minimum thickness precast un L Designation "c” [mm] [mm] SA-FA 0.7T – 65 65 80 SA-FA 1.4T – 68 68 80 SA-FA 2.0T – 70 70 90 SA-FA 2.5T – 75 75 100 90 120 110 140 125 160 Load group 2,5t (0,7t – 2,5t) Load group 10t (5,3t-10t) SA-FA 3.0T – 90 SA-FA 4.0T – 110 Picture 73 SA-FA Note: Minimum thickness Minimum Spacing Permitted load Reinforcement tails placed as close to the anchor as possible. of precast unit Part No 5.0T – 125 Picture 74 Reinforcement bars c b Axial or angled load 45>β≤30° Angled load β>30° Ø mm mm kN kN mm 230 14 11.2 8 200 10/29/2013 CFS-FPA-25-80 110 330 25 20 10 300 CFS-FPA-50-120 150 480 50 40 12 450 CFS-FPA-100-160 200 660 100 80 16 600 Page 30 QUICK LIFT ANCHORS alterations reserved CFS-FPA-14-50 80 L Load gro SA-FA SA-FA SA-FA SA-FA Load gro SA-FA SA-FA SA-FA RECESS FORMER “RBF” The recess former RBF is made of rubber (picture 7 recess formers are available for load range 1,25 - 26 to www.cfsfixings.com 5-16 Quick Lift Clutch The lifting clutch is made of special steel casting. The lifting bolt is inserted into the hole of the lifting anchor and can be removed afterwards. Part No Load Group CFS-F2-15 1.5 CFS-F2-25 2.5 CFS-F2-50 5 CFS-F2-100 10 CFS-F2-260 26 Use of Quick Lift Clutch Engagement Simply insert the lift clutch into the recess formed in the concrete and close the locking bolt manually, ensure that it is fully engaged & flush with the concrete surface. Lifting The quick lift clutch system can be subjected to loads in any direction and no extra or special part is required for angled lifts and turning. It is therefore essential to follow the instructions regarding rebars in the concrete. Once the ring clutch has been engaged in the anchor, the shackle can move in any direction, even under load. Release To release, shift the locking bolt back by hand, this will release the lifting clutch. Marking Every ring clutch is marked with the load capacity and a serial number. Clutches should be examined regularly and re-tested annually. 5-17 www.cfsfixings.com Rubber Recess Former Bayonet Recess former for fixing with holding screw for mounting plate or bayonet fixing Part No Load Group a b c Thread CFS-FRBI-15 1.5 29 62 35 M8 CFS-FRBI-25 2.5 43 104 45 M8 CFS-FRBI-50 5 49 126 59 M8 CFS-FRBI-100 10 67 188 85 M12 CFS-FRBI-260 26 112 233 121 M16 c b a QUICK LIFT ANCHORS www.cfsfixings.com 5-18 Holding Plate For fastening of the recess former onto the formwork Part No Load Group a b c CFS-FIP-15 1.5 45 15 3 CFS-FIP-25 2.5 73 15 4 CFS-FIP-50 5 85 30 4 CFS-FIP-100 10 128 40 6 CFS-FIP-260 26 178 65 8 b c a Holding Screw m For fastening of the recess former through the formwork. Part No Load Group l m CFS-FDV-25 2.5 160 M8 CFS-FDV-50 5 160 M8 CFS-FDV-100 10 160 M12 CFS-FDV-260 26 180 M16 l 5-19 www.cfsfixings.com QUICK LIFT ANCHORS www.cfsfixings.com 5-20
Similar documents
Pressure
reversal: All reversing valves are cast aluminium and therefore highly resistant to corrosion. One-sided sealed, deep groove ball bearings are used for the bedding of the actuating piston. Connecti...
More information