PHASE I ENVIRONMENTAL SITE ASSESSMENT Ganley Pontiac
Transcription
PHASE I ENVIRONMENTAL SITE ASSESSMENT Ganley Pontiac
PHASE I ENVIRONMENTAL SITE ASSESSMENT Ganley Pontiac 25870 Lorain Road North Olmsted, Ohio 44070 PREPARED FOR: Ganley Management Co. c/o ORG Holdings 3733 Park East Drive Beachwood, Ohio 44122 PREPARED BY: RP Consultants, Inc. 8500 Station Street Mentor, Ohio 44060 (440) 946-5888 RP-1824 October 30, 2003 TABLE OF CONTENTS SECTION PAGE(S) Executive Summary Introduction Scope of Investigation Walkover Survey Topography Soils Wetlands Groundwater Pollution Potential Asbestos Containing Materials Polychlorinated Biphenyls Underground and Aboveground Storage Tanks Waste Sites Stored Chemicals Lead Paint City Directories Water Quality Radon Recommendations Informational Sources Site Map Tax Map and Ownership Information Soil Map Wetlands Map Groundwater Pollution Potential Map Topographic Maps Aerial Photographs Photography Database Research 3-6 6 6-7 7-9 9 9-10 10 10 11 11-13 13-14 15 16 16 16-17 17 17-18 19 20 21 22-27 28 29 30 31-32 33-39 40-65 Appendix I 2 EXECUTIVE SUMMARY RP Consultants, Inc. was retained by Ganley Management Company c/o ORG Holdings to conduct an environmental assessment of the property situated at 25870 Lorain Road in North Olmsted, Ohio 44070. The scope of services provided under this project are described in RP Consultant’s contract with Ganley Management Company c/o ORG Holdings. The overall objective of the environmental assessment was to provide an independent, professional opinion regarding potential environmental liabilities, if any, associated with the subject property. RP Consultants, Inc. understands that the results of this project are to be used and relied upon Ganley Management Company. The environmental assessment of the site included a site inspection, an agency database records search, and limited historical research. This assessment has revealed the following recognized environmental conditions (RECs) in connection with the subject property: REC #1: Several aboveground and abandoned in-ground lifts were observed in the main building on the subject property. The remnants of six hydraulic in-ground lifts were observed hanging from the basement ceiling in the main building. The lift equipment was observed to be stained and oil was leaking from the lifts onto the basement floor. One abandoned in-ground lift was also observed in the basement of the main building. Evidence of staining was also observed near this lift. No evidence of staining or leakage was observed near the aboveground lifts on the subject property. Based upon the above information and observations, RP Consultants, Inc. concludes that there a possibility that the abandoned lifts contain PCBcontaminated hydraulic oil. Accordingly, the lifts should be removed from the property and the oil within the lifts should be sampled and analyzed for PCBs. Furthermore, the basement floor should be sampled to determine if they have been contaminated by the leaking lifts. If PCBs are found to be above acceptable levels, proper cleanup and/or disposal 3 under Toxic Substances Control Act 40 CFR 761 and Ohio EPA guidelines should be performed. REC #2: The subject property was surveyed for evidence of aboveground storage tanks (ASTs), underground storage tanks (USTs), and petroleum distribution equipment such as fill caps, vent pipes, pump islands, pipelines, and depressed or stained soil. Three 250-gallon new oil, concrete diked ASTs and two solvent ASTs were observed in the main building on the subject property. One waste oil AST was also observed outside near the northwest corner of the main building on the subject property. No evidence of leakage or staining was observed near the ASTs. A vent pipe was also observed along the east side of the main building on the subject property. Aerial photographs showing the subject property in 1951, 1959, 1977, 1978, 1979, 1988, and 2000 were reviewed. No evidence of ASTs or USTs was noted on the photographs. A file review was conducted at the North Olmsted Fire Department and all pertinent information is as follows: A permit application was filed in September 1989 for the removal of two 550-gallon and one 1000-gallon USTs from the subject property. BP Oil Company was listed as the owner of the USTs. BP Oil Company contacted BUSTR regarding the intent to remove the USTs in September 1989. United Plumbing and Excavation removed the USTs from the subject property on October 20, 1989 as indicated by analytical data in the fire department records. BP Oil Company notified the North Olmsted Fire Department on January 5, 1990 that the excavation was considered to be “clean”. The letter also indicated that the soil removed from the excavation was being transported to Norton Landfill and that the tank cavity was being filled with clean soil. Based upon the above information and observations, RP Consultants concludes that since USTs were removed from the subject property prior to or during the advent of current State of Ohio Bureau of UST 4 Regulations (BUSTR) protocol, there is a possibility that residual contamination remains on the subject property. Furthermore, RP Consultants, Inc. recommends that a BUSTR file review be conducted for the USTs removed in October 1989. It is unclear as to whether or not a Closure Report was submitted to BUSTR since the subject property address is not listed on the Registered Underground Storage Tank list or the Leaking Underground Storage Tank list. Further recommendations will be made after it is determined if BUSTR has documentation regarding the subject property. REC #3: The property was surveyed for evidence of ground contamination such as open leaking drums, old batteries, waste ponds, lagoons, or stressed vegetation that might indicate hazardous waste. Several oil buckets and two floor drains were observed in the basement of the main building. Evidence of slight staining was observed near the buckets and drains. Water and mold damage was observed in the parts storage area in the basement of the main building. Several oil stains were also observed in the shop area in the main building. Aerial photographs showing the subject property in 1951, 1959, 1977, 1978, 1979, 1988, and 2000 were reviewed. No evidence of waste sites was noted on the photographs. A file review was conducted at the North Olmsted Fire Department and all pertinent information is as follows: A fire inspection report indicated that several issues needed to be addressed in the basement of the main building on the subject property, including removing old, unlabeled drums, cleaning up all leakage on the basement floor, and cleaning up the floor area under and around the waste oil tank. An oil spill was reported on the subject property in June 1990 in which approximately 200 gallons of waste crankcase drainings were spilled onto the subject property. The spill was caused by a truck driver who left his truck unattended while the pump was engaged and pumping waste material. The spill headed toward a sewer with approximately 10-15 gallons entering before a wall of oil dry was formed to contain the spill. 5 It should be noted that the past waste generation practices (e.g. from the 1970s) on the subject property are unknown. Accordingly, there is a possibility that the past use of the property has led to contamination in levels that could constitute a release. Subsequently, a phase two is recommended for waste sites. Specifically, soil (and groundwater, if encountered) samples should be taken and analyzed for volatile and semivolatile organic compounds, metals, PCBs and total petroleum hydrocarbons. Also, a mold survey, conducted by a licensed industrial hygienist should be conducted to address the water damage and mold in the basement of the main building. All areas should be sampled and properly remediated as determined by the industrial hygienist. A. INTRODUCTION RP Consultants, Inc. has performed a Phase I Environmental Site Assessment for Ganley Management Company c/o ORG Holdings, 3733 Park East Drive, Beachwood, Ohio 44122. The purpose of this assessment is to identify any environmental conditions associated with the property or any facilities located on the property that may require further investigation or remediation. This is accomplished by direct observations of the property and facilities, and by review of historical information regarding past use of the subject and adjacent properties. Sampling of soils, building materials, air and water is not within the scope of this assessment, however, if potential environmental hazards or liabilities are identified as a result of this assessment, such sampling may be recommended under the Phase II Recommendations section of this report. B. SCOPE OF INVESTIGATION RP Consultants, Inc. was hired to conduct a Phase I Environmental Site Assessment of the property located at 25870 Lorain Road, North Olmsted, Ohio 44070. This assessment was performed within the scope and limitations of the ASTM E-1527-00 Standard Practice for Phase One Site Assessments and RP Consultants, Inc. guidelines and standard operating procedure for phase one site assessments. This report represents site conditions on October 16, 2003. All conclusions and findings are based 6 upon this limited site assessment and historical research conducted by RP Consultants, Inc. We can provide no assurance that information obtained from others is accurate or complete. Furthermore, any change in site condition after the date of the walkover survey is beyond the scope of this assessment. Accordingly, RP Consultants, Inc. cannot make any guarantees concerning future conditions. The client should also be aware that this report is not a guarantee or certification that the site is free of contamination or hazardous materials, but rather it is an opinion of the potential for contamination to exist. Moreover, no tests of any materials or substances have been performed in connection with this assessment. Accordingly, RP Consultants, Inc. cannot absolutely guarantee that the property is free of contamination or hazardous materials or substances. C. WALKOVER SURVEY The property surveyed consists of two single-story brick, block and wood buildings with metal deck roofs and full basements on approximately 5.0 acres of land. The used car building was constructed in the 1950’s or earlier and the main building was constructed in the 1960’s. A retention pond is also located along the north side of the subject property. Improvements to the subject property include an asphalt and concrete parking lot. The walkover survey was conducted on October 16 and 17, 2003 by Patrick Duncan and Erik Ehinger of RP Consultants, Inc. An interview was conducted during the survey with Mr. Mike Hayes, former General Manager for Ganley Pontiac. According to the interviewee, as well as information obtained from reviews of aerial photographs, city directories, tax maps, and a review of files at the North Olmsted Fire Department, the history of the subject property is as follows: Prior to 1951: The use of the subject property is unknown. 1951 to 1959: The subject property is shown as residential and vacant land. The current used car building was shown as a residential property and was listed in city directories as residential from 1962 to 1982. 7 Between 1962 and 1970: The main building was constructed on the subject property. The used car building was listed as residential from 1962 to 1966. 1970 to 1993: The main building was listed as Paradise Honda and Pontiac. The used car building was listed as Pocorelli Hair, As You Like It Photo, and a travel agency from 1986 to 1993. 1998 to 2002: The main building was listed as Ganley Honda and Pontiac. The used car building was listed as Kenneth Paradise in 2002. Present: The subject property is used for Ganley Pontiac. The address of 25876 Lorain Road also appears in City Directories as Ganley Resale in 2002. This property address was not listed from 1962 to 1998. Municipal electric, gas, sewer, and water are available on the subject property. Adjacent properties include: residential properties to the north; Original Mattress Factory, City Club Restaurant, Bob Evan Restaurant, and Ponderosa to the south; AT & T Wireless to the east; and woods and an apartment building to the west. None of the adjacent properties appeared to be affecting the subject property at the time of the walkover survey. Furthermore, none of the neighboring properties appeared on any of the state or federal environmental site lists searched as part of this report. The subject property is listed on Cuyahoga County Tax Map 232, page 34, as parcels 3, 4, 5, 6, 7, 90, 100, and 102. The present owners of the subject property are listed as Michael Paradise, Kay Francis Paradise, and Kenneth Paradise. Previous owners of the subject property are listed as P & D Enterprises, Ltd. and individuals. Information regarding other previous owners was not listed, but could be 8 obtained through a chain of title search, which can be conducted or reviewed at the request of the client. A copy of the tax map is included in this report. It should be noted that the basement in the used auto building was inaccessible at the time of the walkover survey, and several vehicles were being stored in the buildings making the buildings difficult to assess. Accordingly, RP Consultants, Inc. is not responsible for environmental conditions that could not be observed due to lack of access or visibility. D. TOPOGRAPHY The elevation of the subject property is approximately 750 feet above sea level (National Geodetic Vertical Datum of 1929). The local topography slopes to the north-northwest. Major topographical features in the area include Interstate 480 approximately 3/4 miles to the south, Dover Center Road approximately one mile to the west, and Rocky River Reservation approximately one mile to the southeast. In general, the surrounding properties are used for commercial purposes. A copy of the topographic map is included with this report. E. SOILS The predominant soils on the subject property are the Urban landMahoning complex, undulating and Oshtemo-Urban land complex, undulating. The Urban land-Mahoning complex, undulating consists of Urban land (areas covered by concrete and buildings) and a deep, nearly level and gently sloping, somewhat poorly drained Mahoning soil. This soil occurs on glacial till plains and on the higher parts of lake plains. Most areas are irregular in shape, and range from 30 to several hundred acres in size. Urban land-Mahoning complex, undulating, is considered to be a nonhydric soil with hydric components. Accordingly, there is a potential for wetlands development on isolated portions of this soil. 9 The Oshtemo-Urban land complex, undulating soil consists of a deep, well drained Oshtemo soil and Urban land. This soil occurs on beach ridges and terraces. The soil contains about 45 percent Oshtemo sandy loam and 40 percent Urban land. Oshtemo-Urban land complex, undulating, is not considered to be a hydric, or a non-hydric soil with hydric components. Accordingly, the potential for wetlands development is low. A copy of the soil map is included in this report. F. WETLANDS The subject property was surveyed for evidence of wetland systems, such as saturated or inundated soils and wetland vegetation. A retention pond was observed along the north side of the subject property; however, no wetland systems were observed. The national wetlands inventory map was reviewed for the subject property. No evidence of wetlands was noted on the map. Given the developed nature of most of the subject property (buildings, asphalt), RP Consultants, Inc. concludes that there is no evidence to suggest that wetlands are an issue. A copy of the wetlands map is included with the report. G. GROUNDWATER POLLUTION POTENTIAL A review of the Ohio Department of Natural Resources Groundwater Pollution Potential map of Cuyahoga County, Ohio indicated that the subject property lies within zones containing pollution potential indexes between 100 and 159. This indicates that the groundwater on the subject property has a moderate to high vulnerability to contamination. Accordingly, there is a moderate to high probability that contamination could migrate off of the subject property to the neighboring properties, or from the neighboring properties to the subject property. A copy of the groundwater pollution potential map is included in this 10 report. H. ASBESTOS CONTAINING MATERIALS (ACM) The subject property was surveyed for evidence of friable ACM, such as pipe and boiler insulation, and non-friable ACM, such as floor tile and drywall. Drywall, ceiling tile, floor tile, linoleum, and pipe insulation were observed in the buildings. All of the materials were in good condition. The building appears to contain a mixture of old and new building materials. The last date for asbestos in most U.S.-made surfacing materials such as drywall and floor tile is 1980. It should be noted, however, that surfacing materials made after 1980 can still contain asbestos, especially if they were imported (e.g. from Canada or Mexico). Thus, it is possible that ACM could exist in a building of any age. Based upon the above information, a phase two is recommended for nonfriable asbestos only if building materials are to be removed (e.g. if the building is to be demolished or if any areas are to be remodeled). If asbestos is found, then Occupational Safety and Health Administration (OSHA) Guidelines should be followed concerning the abatement plan for the building. If building materials are not to be removed, then they must be assumed to contain asbestos. Accordingly, any damaged areas should be repaired and encapsulated. If this is done, then an operations and maintenance plan following OSHA guidelines should be instituted. Essentially, the plan would involve monitoring the suspect ACM for damage, and making any appropriate repairs. I. POLYCHLORINATED BIPHENYLS (PCBs) The subject property was surveyed for evidence of potential PCBs and possible PCB-contaminated equipment, including transformers, hydraulic lifts, leaking fluorescent light ballasts, elevator motors, and compressors. 11 The following were observed: 1. FLUORESCENT LIGHT BALLASTS Fluorescent light ballasts were observed on the subject property. According to the interviewee, some of the lights were installed prior to 1979. Since PCBs were commonly used in fluorescent light ballasts until 1979, the older fluorescent lights should be considered a potential risk to the subject property. Accordingly, in the event of a leak or explosion, proper cleanup standards as per Toxic Substances Control Act 40 CFR 761 should be followed. 2. POLE AND PAD MOUNTED TRANSFORMERS Multiple pole mounted transformers and one pad mounted transformer were observed on the subject property. The transformers are property of First Energy. No leakage or staining was observed around the transformers. Information regarding the transformers was unavailable from First Energy. While the transformers could be considered a potential risk to the subject property, as leakage could contaminate the property with PCBs and/or petroleum hydrocarbons, any such contamination is the responsibility of First Energy. If the transformers are ever found to be leaking, or are to be removed from the property, First Energy should be contacted regarding remediation and/or removal. 3. COMPRESSOR One compressor was observed in the main building on the subject property. According to the interviewee, the compressor was recently installed as new equipment. Since PCBs have not been used in compressor motor oil since 1979, the compressor is not considered to be a risk to the subject property. 12 4. LIFTS Several aboveground and abandoned in-ground lifts were observed in the main building on the subject property. The remnants of six hydraulic inground lifts were observed hanging from the basement ceiling in the main building. The lift equipment was observed to be stained and oil was leaking from the lifts onto the basement floor. One abandoned in-ground lift was also observed in the basement of the main building. Evidence of staining was also observed near this lift. No evidence of staining or leakage was observed near the aboveground lifts on the subject property. Based upon the above information and observations, RP Consultants, Inc. concludes that there a possibility that the abandoned lifts contain PCBcontaminated hydraulic oil. Accordingly, the lifts should be removed from the property and the oil within the lifts should be sampled and analyzed for PCBs. Further, the basement floor should be sampled to determine if they have been contaminated by the leaking lifts. If PCBs are found to be above acceptable levels, proper cleanup and/or disposal under Toxic Substances Control Act 40 CFR 761 and Ohio EPA guidelines should be performed. Also, RP Consultants, Inc. concludes that PCBs may exist in the older fluorescent light ballasts and/or transformers on the subject property. It should be noted, however, that the equipment does not appear to be leaking at this time, and therefore poses little threat to the subject property. J. UNDERGROUND AND ABOVEGROUND STORAGE TANKS The subject property was surveyed for evidence of aboveground storage tanks (ASTs), underground storage tanks (USTs), and petroleum distribution equipment such as fill caps, vent pipes, pump islands, pipelines, and depressed or stained soil. Three 250-gallon new oil, concrete diked ASTs and two solvent ASTs were observed in the main building on the subject property. One waste oil AST was also observed outside near the northwest corner of the main building on the subject property. No evidence of leakage or staining was observed 13 near the ASTs. A vent pipe was also observed along the east side of the main building on the subject property. Aerial photographs showing the subject property in 1951, 1959, 1977, 1978, 1979, 1988, and 2000 were reviewed. No evidence of ASTs or USTs was noted on the photographs. A file review was conducted at the North Olmsted Fire Department and all pertinent information is as follows: A permit application was filed in September 1989 for the removal of two 550-gallon and one 1000-gallon USTs from the subject property. BP Oil Company was listed as the owner of the USTs. BP Oil Company contacted BUSTR regarding the intent to remove the USTs in September 1989. United Plumbing and Excavation removed the USTs from the subject property on October 20, 1989 as indicated by analytical data in the fire department records. BP Oil Company notified the North Olmsted Fire Department on January 5, 1990 that the excavation was considered to be “clean”. The letter also indicated that the soil removed from the excavation was being transported to Norton Landfill and that the tank cavity was being filled with clean soil. Based upon the above information and observations, RP Consultants concludes that since USTs were removed from the subject property prior to or during the advent of current State of Ohio Bureau of UST Regulations (BUSTR) protocol, there is a possibility that residual contamination remains on the subject property since BUSTR does not appear to have monitored the UST removal activities. Further, RP Consultants, Inc. recommends that a BUSTR file review be conducted for the USTs removed in October 1989. It is unclear as to whether or not a Closure Report was submitted to BUSTR since the subject property address is not listed on the Registered Underground Storage Tank list or the Leaking Underground Storage Tank list. Further recommendations will be made after it is determined if BUSTR has documentation regarding the subject property. 14 K. WASTE SITES The property was surveyed for evidence of ground contamination such as open leaking drums, old batteries, waste ponds, lagoons, or stressed vegetation that might indicate hazardous waste. Several oil buckets and two floor drains were observed in the basement of the main building. Evidence of slight staining was observed near the buckets and drains. Water and mold damage was observed in the parts storage area in the basement of the main building. Several oil stains were also observed in the shop area in the main building. Aerial photographs showing the subject property in 1951, 1959, 1977, 1978, 1979, 1988, and 2000 were reviewed. No evidence of waste sites was noted on the photographs. A file review was conducted at the North Olmsted Fire Department and all pertinent information is as follows: A fire inspection report indicated that several issues needed to be addressed in the basement of the main building on the subject property, including removing old, unlabeled drums, cleaning up all leakage on the basement floor, and cleaning up the floor area under and around the waste oil tank. An oil spill was reported on the subject property in June 1990 in which approximately 200 gallon of waste crankcase drainings were spilled onto the subject property. The spill was caused by a truck driver who left his truck unattended while the pump was engaged and pumping waste material. The spill headed toward a sewer with approximately 10-15 gallons entering before a wall of oil dry was formed to contain the spill. It should be noted that the past waste generation practices on the subject property are unknown. Accordingly, there is a possibility that the past use of the property has led to contamination in levels that could constitute a release. Subsequently, a phase two is recommended for waste sites. Specifically, soil (and groundwater, if encountered) samples should be taken and analyzed for volatile and semi-volatile organic compounds, metals, PCBs and total petroleum hydrocarbons. Also, a mold survey, conducted by a licensed industrial hygienist, should 15 be conducted to address the water damage and mold in the basement of the main building. All areas should be sampled and properly remediated as determined by the industrial hygienist. L. STORED CHEMICALS The property was surveyed for evidence of stored chemicals such as labeled drums. Several types of automotive fluids as well as one 55-gallon drum of window wash fluid were observed in the main building on the subject property. All chemicals appeared to be properly stored and labeled. Based upon the above information and observations, RP Consultants, Inc. concludes that there is no evidence to suggest that chemicals are improperly stored on the subject property. M. LEAD PAINT The property was inspected for potential sources of lead such as peeling paint on old debris. No such evidence was observed. Based upon the age of the buildings, it is possible that lead paint exists in the buildings. A lead paint survey can be conducted at the request of the client. N. CITY DIRECTORIES/SANBORN FIRE INSURANCE MAPS City directories were reviewed at the Cleveland Public Library. Sanborn maps were not available at the Cleveland Public Library. A complete history of the subject property is given in section “C” of this report. SOUTH NEIGHBOR (Original Mattress Factory) Not listed from 1962 to 1974, listed as Swing Set Hair in 1982, Hair Systems in 1986, The Hair Shop from 1990 to 1998, and Mattress Factory in 2002. 16 SOUTH NEIGHBOR (City Club Restaurant) Not listed in 1962, listed as Redwood Tavern from 1966 to 1982, and listed as City Club Restaurant from 1990 to 2002. SOUTH NEIGHBOR (Bob Evans Restaurant) Listed as Red Fox Inn from 1962 to 1970, not listed from 1974 to 1978, and listed as Bob Evans from 1982 to 2002 (All State Sales in 1993 only). SOUTH NEIGHBOR (Ponderosa) Listed as residential from 1962 to 1966, not listed in 1970, and listed as Ponderosa from 1974 to 2002. EAST NEIGHBOR (AT&T Wireless) Not listed from 1962 to 1970, listed as Alder Rube Sporting and Lawson’s from 1974 to 1982, and Eyeglass Factory from 1990 to 2002. WEST NEIGHBOR (apartment building) Listed as apartments from 1962 to 1986, not listed in 1990, and listed as residential from 1993 to 2002. O. WATER QUALITY Since water is supplied to the subject property by a municipal source, a study of water quality is not applicable here. P. RADON A radon gas survey was not conducted as part of this study. According to Ohio Geological Survey Report 144, Geological Controls on Indoor Radon in Ohio, the median indoor radon concentration in North Olmsted, Ohio (zip code 44070) is 2.3 picocuries of radiation per liter of air (pCi/l). This level is below the 4.0 pCi/l "action threshold" recommended by the U.S. EPA for house remediation. 17 It should be noted that the above data does not necessarily indicate that low radon levels exist on the subject property, they only represent a typical concentration for North Olmsted, Ohio 44070. Accordingly, the only definitive method to determine radon concentrations on the subject property is through a radon test, which can be conducted at the request of the client. 18 RECOMMENDATIONS AND CONCLUSIONS N = NO EVIDENCE OF RECOGNIZED ENVIRONMENTAL CONDITIONS OR ISSUES O&M = OPERATIONS AND MAINTENANCE PLAN RECOMMENDED P = POTENTIAL RECOGNIZED ENVIRONMENTAL CONDITIONS D = WETLANDS DELINEATION RECOMMENDED HAZARD Friable Asbestos Containing Materials Non-Friable Asbestos Containing Materials Polychlorinated Biphenyls Aboveground Storage Tanks Underground Storage Tanks Waste Sites Stored Chemicals Lead Based Paint Radon Water Quality Wetlands Sincerely, Patrick W. Duncan Principal Geologist 19 O&M O&M P N P P N Not Available Not Available Not Applicable N INFORMATIONAL RESOURCES CONSULTED Federal NPL site list Federal CERCLIS list Federal CERCLIS NFRAP site list Federal RCRA CORRACTS facilities list Federal RCRA non-CORRACTS TSD facilities list Federal ERNS list OEPA-equivalent NPL OEPA-equivalent CERCLIS OEPA landfill and/or solid waste disposal site lists BUSTR Leaking UST list BUSTR Registered UST list Topographic Map (North Olmsted, Ohio) Wetlands Map (North Olmsted, Ohio) ODNR Groundwater Pollution Potential Map (Cuyahoga County) Information Request (North Olmsted Fire Department) Aerial Photographs (Euclid Blueprint, Cuyahoga County Soil Conservation Service, and US Geological Survey) Cuyahoga County Tax Maps Soil Conservation Service (Cuyahoga County) City Directories Review (Cleveland Public Library) Sanborn Fire Insurance Map Review (Cleveland Public Library) Geological Controls on Indoor Radon Report (ODNR) 20 SITE MAP SHOWING SUBJECT PROPERTY 21 TAX MAP SHOWING SUBJECT PROPERTY 22 OWNERSHIP INFORMATION REGARDING SUBJECT PROPERTY 23 OWNERSHIP INFORMATION REGARDING SUBJECT PROPERTY 24 OWNERSHIP INFORMATION REGARDING SUBJECT PROPERTY 25 OWNERSHIP INFORMATION REGARDING SUBJECT PROPERTY 26 OWNERSHIP INFORMATION REGARDING SUBJECT PROPERTY 27 SOIL MAP SHOWING SUBJECT PROPERTY 28 WETLANDS MAP SHOWING SUBJECT PROPERTY 29 GROUNDWATER POLLUTION POTENTIAL MAP SHOWING SUBJECT PROPERTY 30 2-D TOPOGRAPHIC MAP SHOWING SUBJECT PROPERTY 31 3-D TOPGRAPHIC MAP SHOWING SUBJECT PROPERTY 32 AIR PHOTO DATED 1951 33 AIR PHOTO DATED 1959 34 AIR PHOTO DATED 1977 35 AIR PHOTO DATED 1978 36 AIR PHOTO DATED 1979 37 AIR PHOTO DATED 1988 38 AIR PHOTO DATED 2000 39 SUBJECT PROPERTY AS SEEN FROM LORAIN ROAD 40 VIEW SHOWING NORTH AND EAST SIDES OF SUBJECT PROPERTY 41 VIEW SHOWING NORTH AND WEST SIDES OF SUBJECT PROPERTY 42 VIEW SHOWING SOUTH SIDE OF USED CAR BUILDING ON SUBJECT PROPERTY 43 RETENTION POND ON NORTH SIDE OF SUBJECT PROPERTY 44 EAST SIDE OF MAIN BUILDING ON SUBJECT PROPERTY SHOWING VENT PIPES 45 NORTHWEST CORNER OF MAIN BUILDING ON SUBJECT PROPERTY SHOWING WASTE OIL AST 46 VIEW SHOWING PAD MOUNTED TRANSFORMER ON SUBJECT PROPERTY 47 AUTO SHOWROOM IN MAIN BUILDING ON SUBJECT PROPERTY 48 VIEW SHOWING SHOP AREA IN BASEMENT IN MAIN BUILDING ON SUBJECT PROPERTY 49 VIEW SHOWING SHOP AREA IN BASEMENT IN MAIN BUILDING ON SUBJECT PROPERTY 50 SUSPECT ACM ON PIPING IN BASEMENT OF MAIN BUILDING ON SUBJECT PROPERTY 51 DEBRIS AND STAINING IN SHOP AREA IN MAIN BUILDING ON SUBJECT PROPERTY 52 CLEANING AND WASH AREA IN SHOP IN MAIN BUILDING ON SUBJECT PROPERTY 53 NEW OIL ASTS IN SHOP AREA IN MAIN BUILDING ON SUBJECT PROPERTY 54 WATER DAMAGE AND MOLD IN PARTS STORAGE AREA IN BASEMENT OF MAIN BUILDING ON SUBJECT PROPERTY 55 ABANDONED IN-GROUND HYDRAULIC LIFT IN BASEMENT OF MAIN BUILDING ON SUBJECT PROPERTY 56 ABANDONED IN-GROUND LIFT SYSTEM IN BASEMENT OF MAIN BUILDING ON SUBJECT PROPERTY 57 ABANDONED IN-GROUND LIFTS HANGING DOWN INTO BASEMENT FROM FIRST FLOOR IN MAIN BUILDING ON SUBJECT PROPERTY 58 OIL STAINING FROM ABANDONED LIFTS IN BASEMENT OF MAIN BUILDING ON SUBJECT PROPERTY 59 NEIGHBORING PROPERTY TO THE EAST (AT & T WIRELESS) 60 NEIGHBORING PROPERTIES TO THE WEST (WOODS AND APARTMENT BUILDING) 61 NEIGHBORING PROEPRTY TO THE WEST (APARTMENT BUILDING) 62 NEIGHBORING PROPERTY TO THE SOUTH (ORIGINAL MATTRESS FACTORY AND CITY CLUB RESTAURANT) 63 NEIGHBORING PROPERTY TO THE SOUTH (BOB EVANS RESTAURANT) 64 NEIGHBORING PROPERTY TO THE SOUTH (PONDEROSA) 65