SC Design Guidelines
Transcription
SC Design Guidelines
ARCHITECTURAL GUIDELINES TABLE OF CONTENTS Architectural Approval Component I. Homesite Plan A. Site Plan; Building Envelope B. Set-Back Lines II. Utilities A. Aerobic System B. Other Utilities III. Landscape & Grounds A. Site Grading & Drainage B. Driveways, Headwalls & Culverts C. Mailboxes D. Lighting E. Irrigation Systems F. Landscaping G. Fencing H. Pools IV. Building Design and Materials A. Architecture B. Floor Plans, Elevations C. Square Footage D. Materials E. Roof F. Use of Color G. Garages V. Guidelines and Procedures A. Procedures B. No Waiver of Future Approvals C. Variances D. Limitation of Liability E. Certificate of Compliance Stone Canyon Architectural Guide as of 2-26-09 -1- ARCHITECTURAL APPROVAL COMPONENT Great care has been taken to ensure that the natural beauty, quality of life and personal investments within Stone Canyon are preserved. Stone Canyon’s Architectural Review Process will help ensure that only homes that are well designed, with good proportion, balance and color are constructed within our community. By staying true to this approval process, we can create a community of diverse style, high level of quality and long-term value. No structure or thing shall be placed, erected, orinstalled upon any Lot and no improvements or other work (including staking, clearing, excavation, grading and other site work, exterior alterations of existing improvements, or planting or removal of landscaping) shall take place within Stone Canyon, except in compliance with the Stone Canyon Master Declaration (your attention is specifically referred to Article IV thereof), the Restrictions and Rules and the Architectural Guidelines. All items governed by this document will require written architectural approval by the architectural “Reviewer” as that term is defined in the Master Declarations of Stone Canyon prior to construction/installation ofany structures or features. In the event that supplemental features not included in original submittal are desired (i.e. additional fencing, detached structures, external re-models), a separate submission must be made for these items seeking written Architectural approval so that construction may begin on these additional items. Any fees charged by the Reviewer and any other professional (including, without limitation, any professional employed by the Declarant or the Association) in relation to reviewing the application shall be paid by the applicant. I. Homesite Plan A. Site Plan; Building Envelope . A scaled lot layout file will be provided to builders for each lot. This layout will include all easements appearing on the recorded plat for the subject lot, as well as minimum suggested Finished Floor Elevations (FFE). As part of the Architectural app lication, builders will be asked to show, to scale, the layout of all planned structures, including fencing, for each lot. This document will serve as the Site Plan for the subject lot. B. Set-Back Lines . No buildings, outbuildings, structures, or parts thereof shall be constructed or maintained on lots nearer to the property lines than the set-back lines provided herein or shown on the accompanying plat. The minimum building set-back lines for dwellings or other outbuilding structure shall be: Front Yard: Side Yard: 35 feet 10 feet Back Yard: Other Side Yard: 20 feet 15 feet II. Utilities A. Aerobic System . All lots within Settler’s Creek shall have an in dividual aerobic septic system with alarm incorporated. Aerobic systems are to be located on side yards within 25 feet from the front of the home, unless topography or Stone Canyon Architectural Guide as of 2-26-09 -2- context requires alternative placement and new location is approved. Our goal is for aerobic systems to be readily available such that they are easily accessible by third-party service workers at all times, i.e., not behind fences or within landscaped beds. Although not expressly detailed in this document at this time, new technology and/or certain additional security or maintenance features may be added to the Architectural Guidelines, and therefore required for all new individual aerobic systems within Stone Canyon. All lots within Stone Canyon are subject to any agreement initiated by the Developer for the scheduled, regular maintenance of individual aerobic systems. Each lot may be subject to ne Canyon Deed of assessments for such maintenance, as allowed in Stone Dedication (see below). As per the Covenants, Conditions & Restrictions for Stone Canyon: Article VI, 1. (j). Individual Sanitary Sewer Disposal System : Sewage shall be disposed of by individual on-site Department of Environmental Quality approved aerobic sewage disposal systems. No other on-site individual sewage disposal system shall be allowed without written approval from the Declarant. All sewage disposal systems shall be installed and maintained in accordance with the rules and regulations set forth by the Oklahoma Department of Environmental Quality. The Declarant reserves the right to designate an approved third-party contractor with experience in installing and/or maintaining aerobic sewage disposal systems for the purpose of performing regular maintenance and monitoring of functions of all such aerobic systems within Stone Canyon. The fees for such services may be satisfied through regular and/or special assessments imposed on each Lot as provided in the Master Declaration. The Declarant further reserves the right to specify the general location of the individual aerobic system upon each Lot pursuant to the site plan requirements contained within the Architectural Guidelines of Stone Canyon. The precise plan and specifications of such aerobic system, including (without limitation) any new applications related thereto, may be specially designated by the Declarant in order to ensure the optimum performance and monitoring of such aerobic system. In the event Declarant or the Association determines that an Owner of a Lot is not taking the necessary action to assist in the proper maintenance or functioning of such Owner’s aerobic system, then the Declarant or the Association, or their respective designee, may, but shall not be obligated to, perform such maintenance or function and the cost of such service shall reimbursed by the Lot Owner whose aerobic system was serviced. In the event such Lot Owner does not pay for such service within thirty (30) days after request for payment, such costs shall become a lien against such Lot subject to the terms and conditions of the Master Declaration. Please show proposed location of Aerobic System on Site Plan that is submitted for Architectural Approval. Stone Canyon Architectural Guide as of 2-26-09 -3- B. Other Utilities . 1. Gas meters must be located near the house and appropriately landscaped such that the meters are not easily visible. 2. Stone Canyon has contracted with AT&T to provide our residents with the newest technology for phone, internet, television and cable. In order to ensure all current and future residents will be able to benefit from this technology, certain wiring specifications are recommended for every home in Stone Canyon. Please see Appendix E for AT&T wiring specifications diagram. III. Landscape & Grounds The rural setting of Stone Canyon contemplates an overland drainage system whereby storm water is conveyed to certain areas along the surface of the ground. Bar ditches along the roadway and drainage easements along lot line boundaries will be used to convey large amounts of storm water during and after significant rainfall events. Furthermore, very heavy rainfall can result in bar ditches and drainage easements being inundated by storm water. Storm water can overflow these conveyance systems and travel across yards and driveways for significant periods of time until the flow of storm water recedes back into the conveyance systems. It is not uncommon for ponding to occur in areas within the yard after such rainfall events. This method of overland storm water conveyance is different than the underground storm sewers fund in many non-rural settings. Therefore, although the appearance of rushing storm water across yards may seem extraordinary to residents who have only witnessed urban drainage systems, there is nothing inappropriate about such rushing overland storm water in the more rural settings found in Stone Canyon. A. Site Grading & Drainage . Builder and Homeowner have joint responsibility to create a grading plan specific to each lot’s needs. Grading plans for each lot must consider the individual topography features, future irrigation plans, provide for any special needs, and meet the minimum customary standards of at least one (1) foot of fall in every ten (10) feet away from dwelling and all structures, for a minimum distance of 10 feet. Roadways and/or adjacent lots must not receive dirt, mud, debris, or increased/altered water flow from the building site or homesite. Builder/Owner will be responsible for correcting these issues at Builder/Owner expense. Minimum recommended Finished Floor Elevations (FFE) will be provided on Final Plat . Use of square hay bails and silt fencing during construction is required. B. Driveways, Headwalls & Culverts . All driveways into lot from any street must be constructed of concrete or asphalt, at least sixteen (16) feet in width, and incorporate a headwall and drainage culvert. Any concrete stain to be natural color (i.e. grey, brown, black). Headwalls are to conform to the Reviewer’s approved specifications in size, shape, placement, and safety lighting as illustrated in Appendix C. Safety lighting is the only allowed lighting for any headwall, and consists of a down flood light Stone Canyon Architectural Guide as of 2-26-09 -4- placed midway on the inside of each head wall, for illumination of driveway, and minimizing glare to drivers. The street-side edge of each headwall is to be placed no closer than twenty-four (24) inches from edge of street, unless otherwise approved by the Reviewer. Mailboxes, statues, lamps and any other extra features may not be incorporated into headwalls. Culverts are to be made using HDPE or PVC pipe, and installed according to Developer’s Engineer and Rogers County standards listed on Final Plat, and should allow for no exposed concrete, metal or piping. C. Mailboxes . All mailboxes in Stone Canyon are to be unifor m and of Reviewer’s choice. Specific order information is available from the Reviewer upon request. All mailboxes are to be free-standing, on a concrete pad, and placed in appropriate manner near street. D. Lighting . All lighting features are to be kept in good working condition. 1. Yard Lamps . Yard lamps, on a photocell for operation during dark hours, will be required for every home in Stone Canyon Lamps are to be placed twenty-five (25) feet from the edge of the street, anywhere between driveway and front yard. Poles and light features to be of Reviewer’s choice, or as approved. Specific order information is available from the Reviewer upon request. Desired placement of yard light to be shown on Site Plan for approval. 2. Home Lighting. Home lighting is required for every home. Four (4) up flood lights are to be placed such that the entire front elevation of the home is illuminated. Additional lights to illuminate the home or landscaping are allowed, provided they do not disrupt or distract neighbors or traffic. E. Irrigation Systems . Every lot must incorporate an irrigation system for at least the front yard and associated landscaping. F. Landscaping . Please refer to Appendix A for examples of the types of landscape plans that are appropriate for homes in S tone Canyon. Full Landscape Plan should be submitted to Architectural Committee prior to installation and/or occupancy, which ever may occur first. Landscape plan should include types of fauna to be incorporated, as well as placement of landscape beds and trees. Landscape Plan should be implemented upon completion of home or within one month (30 days) of occupancy. No planting locations will be approved that interfere with the maintenance and/or access to common areas or Stone Canyon irrigation systems. Unoccupied lots are to be kept mowed on a reasonable schedule and kept free from debris. 1. Sod. Front, back and side yards of each lot to be laid with sod, including bar ditch. Stone Canyon Architectural Guide as of 2-26-09 -5- 2. Trees. The final combination of pre-existing and new planted trees should be: Front Yard - a minimum of three (3) trees of at least 2” caliper. Back Yard – a minimum of two (2) trees of at least 2” caliper. All mandatory new planted trees are to be a minimum of 2” caliper, and chosen from the Approved Tree List. Any additional desired trees may be any size of homeowner’s choice, but also chosen from the Approved Tree List, found in Appendix D. 3. Plantings. The Suggested Supplemental Plantings List is also available in Appendix D. This grouping of native and ornamental fauna contains those species that are compatible with the region and add a pleasing aesthetic to landscaping. G. Fencing . All fences must be approved prior to installation. Please mark fence placement and materials on submitted Site Plan. Please reference the sample application’s site plan for an example of labeling type and placement. Placement: 1. Front Yard fencing may consist of post and rail, iron or masonry to match the dwelling. Front yard fencing is to be placed parallel to the front face of the dwelling and may be flush with the dwelling face or set back as deemed appropriate for side yards not containing aerobic systems. The side yard that contains the aerobic system must have a front fence set-back of least twenty-five (25) feet to accommodate side yard aerobic system sites. On regular rectangle-shaped lots, front fencing may extend to the side property line on either side of the lot. For corner lots: the front fence may extend toward the street as far as the build line along the street; for a side yard not along a street, the side fence may extend to the property line. 2. Side Yard fence may consist of a planting screen or “Post and Rail” fence. Within typical rectangle-shaped lots, side fence may be placed along side property lines from the front fence to the back yard fence. For corner lots, side fencing along any street is to follow the build line in the side yard, typically 35’ from the street. Side yards on corner lots that do not follow a street may follow the side property line. 3. Back Yard fencing should be within fence easement along back property line of lot. 4. Pools (back yard only) may have plantings for privacy screen, ornamental iron fence or masonry fence/wall to match the dwelling. 5. Back Yard fencing may consist of a planting screen or “Post and Rail” fence. Back Yard fencing to be placed along back property line, within fence easement. Stone Canyon Architectural Guide as of 2-26-09 -6- Material Specifications: 1. Privacy : Wood Privacy Fence will not be allowed into Stone Canyon 2. Post & Rail fencing must consist of five (5) inch diameter posts. Fence height must be (5) feet high, 3 rail, and incorporate black vinyl chain link. Wood stain on fence posts to be a neutral, natural wood tone, or clear sealant. 3. Masonry Wall of material and style to match dwelling and associated structures, must be a minimum of five (5) feet tall, or as otherwise approved. 4. Iron Fencing: Ornamental/Iron must be a minimum of five (5) feet tall, or as otherwise approved. 5. Plantings- see Suggested Supplemental Plantings List for examples of appropriate plantings that offer privacy with full growth. Certain additional hardscape/landscape features may be considered for Architectural approval, if their purpose is decorative in nature and not for the intention of fencing. No fence that is not approved may be constructed within Stone Canyon. H. Pools . No above ground pools allowed on any unit. IV. Building Design and Materials A. Architecture : Home styles welcomed to Stone Canyon include French Country, Traditional, and Tudor; additional styles such as Mediterranean or Tuscan will also be considered, and may be approved on a case by case basis. Any special considerations or allowances must be approved on a case by case basis. Please refer to Appendix A for examples of Architectural Styles and features. B. Floor Plans, Elevations : Floor Plans for every story, as well as Elevation s for all four sides of structure will be required for Architectural Review. Homes over two story will require Architectural approval. C. Square Footage : Single story homes must contain a minimum of 2500 square feet of living space. Two story homes must contain a total of over 2600 square feet of living space; ground level to exceed 1600 square feet. Square footage shall be computed on measurements over frame of living space exclusive of porches, patios, and garages. D. Materials : All Structures in Stone Canyon must be construct ed of masonry (i.e. brick, stone, or stucco) over 75% of building, excluding windows. Stone Canyon Architectural Guide as of 2-26-09 -7- E. Roof : All roof accessories such as vents, pipes and flashings shall be copper or painted to match the roof. Whenever possible, fixture vents, hot water tank and furnace vents should be located on the side or rear of the roof to reduce visibility from street. Full guttering is required; colors should be appropriate to the overall color scheme of the dwelling, and/or consistent with roof accessories colors. 1. Pitch of at least 9/12 over 75% of roof required, or as otherwise approved for specific styles. 2. Shingles. Quality of or exceeding Heritage II. 3. Chimney Caps are to be of architectural quality. 4. Shingle Color. Mandatory use of Earth-tone colors (i.e. Weathered Wood, Black, Multi-Gray). Non Earth-tone color shingles must be approved. F. Use of Color : All colors incorporated into any aspect of the exterior of the dwelling or any other structures on the lot must be thoughtfully planned to be in harmony with each other, and to be subtle in nature. Extreme colors of nonnatural hue will not be allowed. Please refer to Appendix A for sample groupings of approved color schemes. For submittal for Architectural approval, digital photographs of grouped color samples in adequate lighting are encouraged. G. Garages : All dwellings shall incorporate garages suitable for accommodating a minimum of two (2) standard size automobiles. Architectural-styled doors are required, i.e. doors with wood/composite cross-back features, windows, designer color, etc. Typical panel doors will not be appropriate. See Appendix B for examples of appropriate garage doors. Carports shall not be permitted. 1. Attached Garagesmust be “side-entry” only and not directly face the street in front of the lot. Attached tandem/3 car garages may face the front of lot if appropriately set back from the front of dwelling and approved by the Architectural Committee. 2. Detached Garages may have doors that face the front of the lot. These structures must be constructed behind the back build line of the dwelling using identical materials and colors as dwelling, as well as meet the same architectural requirements of the Home, including roof pitch and masonry requirements. V. Guidelines and Procedures A. Procedures . Except as otherwise specifically provided in theArchitectural Guidelines, no activities shall commence on any portion of Stone Canyon until an application for approval has been submitted to and approved by the Reviewer. Such application shall include plans and specifications showing site layout, structural design, exterior elevations, exterior materials and colors, landscaping, Stone Canyon Architectural Guide as of 2-26-09 -8- exterior lighting, irrigation, and other features of proposed construction, as applicable. The Architectural Guidelines and the Reviewer may require the submission of such additional information as may reasonably be necessary to consider any application. B. No Waiver of Future Approvals. Each Owner acknowledges that the persons reviewing applications under this Article will change from time to time and that opinions on aesthetic matters, as well as interpretation and application of the Architectural Guidelines, may vary accordingly. In addition, each Owner acknowledges that it may not always be possible to identify objectionable features until work is completed, in which case it may be unreasonable to require changes to the improvements involved, but the Reviewer may refuse to approve similar proposals in the future. Approval of applications or plans, or in connection with any other matter requiring approval, shall not be deemed to constitute a waiver of the right to withhold approval as to any similar applications, plans, or other matters subsequently or additionally submitted for approval. C. Variances. The Reviewer may authorize variances from compliance with any of its guidelines and procedures when circumstances such as topography, natural obstructions, hardship, or aesthetic or environmental considerations require, but only in accordance with duly adopted rules and regulations. No variance shall (a) be effective unless in writing; (b) be contrary to this Declaration; or (c) preclude the Reviewer from denying a variance in other circumstances. For purposes of this Section, the inability to obtain approval of any governmental agency, the issuance of any permit, or the terms of any financing shall not be considered a hardship warranting a variance. D. Limitation of Liability. The standards and procedures established by this Article are intended as a mechanism for maintaining and enhancing the overall aesthetics of Stone Canyon; they do not create any duty to any Person. Review and approval of any application pursuant to this Article may be made on the basis of aesthetic considerations only, and the Reviewer shall not bear any responsibility for ensuring the structural integrity or soundness of approved construction or modifications, nor for ensuring compliance with building codes and other governmental requirements, nor for ensuring that all dwellings are of comparable quality, value of size, or similar design, or aesthetically pleasing or otherwise acceptable to neighboring property owners . Declarant, the Association, the Board, any committee, or member of any of the foregoing shall not be held liable for soil conditions, drainage or other general sight work; any defects in plans revised or approved hereunder; any loss or damage arising out of the action, inaction, integrity, financial condition, or quality of work of any contractor or its subcontractors, employees, or agents, whether or not Declarant has approved or featured such contractor as a builder in Oklahoma; or any injury, damages, or loss arising out of the manner of quality or other circumstances of approved construction on or modifications to any Unit. In all matters, the Association shall indemnify the Declarant, the Board, the ARC, and the members of each as provided in Section 7.6. Stone Canyon Architectural Guide as of 2-26-09 -9- E. Certificate of Compliance . Any Owner may request that the Reviewer issue a certificate of architectural compliance certifying that there are no known violations of this Article or the Architectural Guidelines. The Association shall either grant or deny such request within thirty (30 ) days after receipt of a written request and may charge a reasonable administrative fee for issuing such certificates. Issuance of such a certificate shall preclude the Association from taking enforcement action with respect to any condition as to which the Association had notice as of the date of such certificate. Stone Canyon Architectural Guide as of 2-26-09 - 10 -