table of contents - coatingsmall.com
Transcription
table of contents - coatingsmall.com
TA B L E O F C O N T E N T S To go directly to a TDS, click on the product name / application. To return to this page, click on the LIMCO logo on any TDS. A p p l i c a t i o n P ro c e d u re s Standard Preparation for Plastic Parts Standard Preparation for Steel, Aluminum & Galvanized Metals Standard Preparation for OEM and Cured Finishes Supreme PLUS Basecoat Blending Procedure - U.S. National Rule VOC Supreme PLUS Basecoat Blending Procedure - Low VOC Recommendation U n d e rc o a t s 800K 2K Primer Surfacer - Primer Surfacer Application with LH810, LH820 800K 2K Primer Surfacer - Primer Surfacer Application with LHF, LHM, LHS 800K 2K Primer Surfacer - Tinted Wet-On-Wet Sealer Application with LH810, LH820 800K 2K Primer Surfacer - Tinted Wet-On-Wet Sealer Application with LHF, LHM, LHS 846 1K Acrylic Primer - Primer Application H1000 1K Waterborne Primer - Primer Surfacer Application LP20 Epoxy Primer - Primer Application LP20 Epoxy Primer - Low VOC Primer Application LP20 Epoxy Primer - Primer Surfacer Application LP20 Epoxy Primer - Low VOC Primer Surfacer Application LP20 Epoxy Primer - Wet-On-Wet Sealer Application LP20 Epoxy Primer - Low VOC Wet-On-Wet Sealer Application LP100 Etch Primer - Primer Application LP100 Etch Primer - Low VOC Primer Application LP610 Low VOC Primer - Primer Surfacer Application LP610 Low VOC Primer - Sealer Application LP620 Low VOC Primer - Primer Surfacer Application LP620 Low VOC Primer - Low VOC Primer Surfacer Application LP620 Low VOC Primer - Sealer Application LP620 Low VOC Primer - Low VOC Sealer Application LS56 1K Sealer - Wet-On-Wet Sealer Application LS800 2K Sealer - Wet-On-Wet Sealer Application PS21nr 1K Gray Sealer - Wet-On-Wet Sealer Application To p c o a t s Limco Synthetic Enamel (Limco 1) - U.S. National Rule VOC Limco Synthetic Enamel (Limco 1) with Catalyst - U.S. National Rule VOC Limco Acrylic Enamel (Limco 2) - U.S. National Rule VOC Limco Urethane (Limco 3) - U.S. National Rule VOC Limco Low VOC Urethane (Limco 3) - 420 gms/liter (3.5 lbs/gal) VOC Limco Basecoat (Limco 4) - U.S. National Rule VOC Limco Basecoat (Limco 4) with hardener - U.S. National Rule VOC Limco Direct-to-metal Light Industrial Topcoat (Limco 5) - U.S. National Rule VOC Limco Low VOC Industrial Urethane Single Stage (Limco 7) - 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Acrylic 1K Single Stage - U.S. National Rule VOC Supreme PLUS Low VOC Acrylic 1K Single Stage - 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage - 420 gms/liter (3.5 lbs/gal) VOC US. Rev. 3/22/16 AD2503L To p c o a t s c o n t i n u e d Supreme PLUS Acrylic 2K Single Stage - U.S. National Rule VOC Supreme PLUS Low VOC Acrylic 2K Single Stage - 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage - 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Urethane Single Stage with LA2799 - U.S. National Rule VOC Supreme PLUS Urethane Single Stage with LA2999 - U.S. National Rule VOC Supreme PLUS Low VOC Urethane Single Stage with LA2799 - 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage with LA2899 - 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage with LA2799 - 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage with LA2899 - 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Basecoat - U.S. National Rule VOC Supreme PLUS Low VOC Basecoat - 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS 2K Direct-to-metal - U.S. National Rule VOC Supreme PLUS 2K Direct-to-metal - 420 gms/liter (3.5 lbs/gal) VOC C l e a rc o a t s LC4000 Clearcoat - U.S. National Rule VOC LC4100 High Solids Clearcoat - U.S. National Rule VOC LC4200 Low VOC Clearcoat - 250 gms/liter (2.1 lbs/gal) VOC LC4500 Express Clear - U.S. National Rule VOC LC4800 Low 2.0 VOC Express Clear - 250 gms/liter (2.1 lbs/gal) VOC Miscellaneous 892 Flex Agent LE800 Fisheye Eliminator LF10 Flattening Agent A P P L I C AT I O N P R O C E D U R E S Standard Preparation for Plastic Parts General Cleaning This system is used to repair damaged flexible or rigid plastic parts, or to refinish replacement plastic parts. Wash all areas to be refinished with water and a mild detergent soap. Rinse thoroughly and let dry. Clean all areas to be painted with plastic cleaner. R-M 902 Plastic Prep-Cleaner, then R-M 909 Final Wipe Sanding Prepare any areas that are to be painted by scuffing with a fine scuff pad. Scotchbrite #7447 Cleaning Use an air blow gun to remove all traces of dust and dirt from the cracks and surfaces of the vehicle. R-M 902 Plastic Prep-Cleaner, then R-M 909 Final Wipe Clean all areas to be painted with plastic cleaner. Do not allow plastic cleaners to dry on the surface. Apply wet and then dry with a clean rag. Pre-prime For bare plastic on flexible plastic parts, apply one coat of 868, 869 or 870. Do not sand. For bare plastic on semi-rigid or rigid parts, apply one coat of 868, 869 or 870. Primer Surfacer For flexible parts, apply 2 or 3 coats of primer surfacer mixed with flex additive over any areas that require filling. After drying, finish sand with 240 to 320 grit dry, or 280 to 500 grit wet. For semi-rigid or rigid parts, apply 2 or 3 coats of primer surfacer. After drying, finish sand with 240 to 320 grit dry, or 280 to 500 grit wet. Sealer US. Rev. 11/21/14 Apply 1 medium wet coat over entire part. Allow to flash for 20 to 30 minutes. See the sealer technical reference sheets for flexed mix ratios. R-M 868 1K Plastic Primer R-M 869 1K Low VOC Adhesion Promoter R-M 870 High Solids Adhesion Promoter for Plastics 800K 2K Primer Surfacer 846 1K Acrylic Primer 892 Flex Agent LP20 Epoxy Primer (rigid parts only) LP610 Low VOC Primer (rigid parts only) LP620 Low VOC Primer (rigid parts only) 800K 2K Primer Surfacer LP20 Epoxy Primer (rigid parts only) LP610 Low VOC Primer (rigid parts only) LP620 Low VOC Primer (rigid parts only) LS56 1K Sealer LS800 2K Sealer PS21nr 1K Gray Sealer A P P L I C A T I O N P R O C E D U R E S Standard Preparation for Plastic Parts Topcoat Clearcoat All Basecoats and 1K Acrylic / Synthetic Enamel colors maybe used on plastic parts without a flex additive. For all other topcoats see specific technical data sheet for flex recommendations. All Limco Topcoats 892 Flex Agent Apply 2 coats of clear over, Limco Basecoat colors. Limco 892 Flex Agent must be added the Limco clearcoats. See the clearcoat's technical reference sheet for flexed mix ratios. LC4000 Clearcoat LC4100 High Solids Clearcoat LC4200 Low VOC Clearcoat LC4500 Express Clear LC4800 Low 2.0 VOC Express Clear 892 Flex Agent Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Refer to the appropriate Technical Data Sheet(s) for detailed processing information. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. A P P L I C AT I O N P R O C E D U R E S Standard Preparation for steel, aluminum, & galvanized metals General Use this procedure to prepare bare steel, aluminum, zinc coated or galvanized metals. Cleaning Remove all traces of oil, grease, welding residue or any other material with wax and grease remover. Remove any traces of rust by sanding, wire wheel, brush or sandblasting. Remove all traces of paint stripper by following manufacturer’s instructions. Sanding Steel: dry sand with 80 to 180 grit sandpaper. 203 Wax and Grease Remover, then 139 Final Wash Cleaner Aluminum: dry sand with 120 to 180 grit sandpaper. Zinc or galvanized metal: use coarse scuff pad. (Do not remove zinc or galvanized coating.) Cleaning Blow off any dust and reclean metal with 139 Final Wash Cleaner. 139 Final Wash Cleaner Do not allow cleaner to dry on the surface. Apply wet and then dry with a clean rag. Notes Prime bare metal as soon as possible to prevent further oxidation. Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Refer to the appropriate Technical Data Sheet(s) for detailed processing information. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. US. Rev. 11/21/14 A P P L I C AT I O N P R O C E D U R E S Standard Preparation for OEM and cured finishes General Cleaning Use this procedure to repair or refinish OEM finishes or fully cured, sound old paint work. Wash all areas to be refinished with water and a mild detergent soap. Rinse thoroughly and let dry. Clean all areas to be painted with 203 Wax and Grease Remover, then do a final wipe with 139 Final Wash Cleaner. Sanding 203 Wax and Grease Remover, then 139 Final Wash Cleaner Dry sand all painted areas and any body filler areas that will be primed with 240 grit sandpaper. Be sure to only prime over sanded areas. Sand any areas that will be topcoated directly with 400 grit or finer wet or 320 grit or finer dry. Prepare any areas that are to be blended into by compounding and scuffing with a fine scuff pad. Cleaning Use an air blow gun to remove all traces of dust and dirt from the cracks and surfaces of the vehicle. Clean all areas to be painted with pre-paint cleaner 139 Final Wash Cleaner making sure to remove all residue. Do not allow pre-paint cleaners to dry on the surface. Apply wet and then dry with a clean rag. Notes 139 Final Wash Cleaner Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Refer to the appropriate Technical Data Sheet(s) for detailed processing information. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. US. Rev. 11/21/14 A P P L I C AT I O N P R O C E D U R E S Supreme PLUS Basecoat Blending Procedure U.S. National Rule VOC General Preparation Pre-prime Supreme PLUS Basecoat U.S. National Rule VOC is based upon a modified acrylic resin system that can be blended for the repair of original basecoat/clearcoat finishes. Follow the appropriate procedures in the “Standard Preparation” section. Apply 1 or 2 coats of precoat primer to all bare metal areas. Allow sufficient flash time between coats. Do not sand. Allow to dry for 30 minutes before applying primer surfacer. LP20 Epoxy Primer LP100 Etch Primer Primer Surfacer Build up any damaged areas with 2 or 3 coats of primer surfacer. After drying, sand dry with 320 grit sandpaper or sand wet with 400 grit sandpaper. * Dry sand only and can not be used over LP100. H1000 1K Waterborne Primer * 800K 2K Primer Surfacer 846 1K Acrylic Primer LP20 Epoxy Primer LP610 Low VOC Primer LP620 Low VOC Primer Sealer A sealer can improve holdout, maximize adhesion and minimize sand scratch swelling. Apply sealer per technical reference sheets. 800K 2K Primer Surfacer LP20 Epoxy Primer LP610 Low VOC Primer LP620 Low VOC Primer LS56 1K Sealer LS800 2K Sealer PS21nr 1K Gray Sealer US. Rev. 11/21/14 A P P L I C A T I O N P R O C E D U R E S Supreme PLUS Basecoat Blending Procedure U.S. National Rule VOC Blending Procedure Repair area should be sanded with 320-400 grit sandpaper for topcoating with Supreme PLUS Basecoat. Sand the rest of the panel with 800-1000 grit sandpaper. Clean area with pre-paint cleaner. 139 Final Wash Cleaner Apply 1 coat of LA1202 mixed 1:1 to 1:3 with LR11 over the area to be blended, let that flash for 10 minutes. Apply color as needed to achieve proper hiding, make sure to stay inside the area with the LA1202 mixture on it. Supreme PLUS Basecoat Blend out color as needed into LA1202 mixture. Allow 10 minutes flash before applying first coat of clear over entire blend area. LC4100 High Solids Clearcoat LC4500 Express Clear Apply second wet coat of clear over the entire panel. Notes Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Refer to the appropriate Technical Data Sheet(s) for detailed processing information. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. A P P L I C AT I O N P R O C E D U R E S Supreme PLUS Basecoat Blending Procedure Low VOC Recommendation General Preparation Pre-prime Supreme PLUS Basecoat Low VOC is based upon a modified acrylic resin system that can be blended for the repair of original basecoat/clearcoat finishes. Follow the appropriate procedures in the “Standard Preparation” section. Apply 1 or 2 coats of precoat primer to all bare metal areas. Allow sufficient flash time between coats. Do not sand. Allow to dry for 30 minutes before applying primer surfacer. LP20 Epoxy Primer LP100 Etch Primer Primer Surfacer Build up any damaged areas with 2 or 3 coats of primer surfacer. After drying, sand dry with 320 grit sandpaper or sand wet with 400 grit sandpaper. * Dry sand only and can not be used over LP100 H1000 1K Waterborne Primer * LP20 Epoxy Primer LP610 Low VOC Primer LP620 Low VOC Primer Sealer A sealer can improve holdout, maximize adhesion and minimize sand scratch swelling. Apply sealer per technical reference sheets. LP20 Epoxy Primer LP610 Low VOC Primer LP620 Low VOC Primer US. Rev. 11/21/14 A P P L I C A T I O N P R O C E D U R E S Supreme PLUS Basecoat Blending Procedure Low VOC Recommendation Blending Procedure Repair area should be sanded with 320-400 grit sandpaper for topcoating with Supreme PLUS Low VOC Basecoat. Sand the rest of the panel with 800-1000 grit sandpaper. Clean area with pre-paint cleaner. 909 Final Wipe (low VOC mix) Apply 1 coat of LC4200 or LC4800 mixed 4:1:600-800% with LR21 over the area to be blended, let that flash for 10 minutes. Supreme PLUS Low VOC Basecoat Apply color as needed to achieve proper hiding, make sure to stay inside the area with the over reduced clear mixture on it. LC4200 Low VOC Clearcoat LC4800 Low 2.0 VOC Express Clear Blend out color as needed into over reduced clear mixture. Allow 10 minutes flash before applying first coat of clear over entire blend area. Apply second wet coat of clear over the entire panel. Notes Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Refer to the appropriate Technical Data Sheet(s) for detailed processing information. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S 800K 2K Primer Surfacer Primer Surfacer Application with LH810, LH820 Description: Limco 800K 2K Primer Surfacer is a very fast curing, easy sanding primer, that provides good sand scratch filling, no settling in the can, excellent adhesion and topcoat holdout. Materials: Primer Surfacer: 800K Hardeners: LH810 LH820 Flex Agent: 892 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat) R-M 902 Plastic Prep-Cleaner 220 grit R-M 902 Plastic Prep-Cleaner NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: US. Rev. 11/21/14 Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. T E C H N I C A L D A T A 800K 2K Primer Surfacer Primer Surfacer Application with LH810, LH820 Flexed S Mixing ratio: 4:1 4:1:1 Primer 4 parts 800K 4 parts 800K Hardener 1 part LH810 or LH820 1 part LH810 or LH820 Flex Agent — 1 part 892 Potlife at 68°F/20°C 1.5 hours 1.5 hours Spray viscosity Ford #4 @ 68°F/20°C 18 - 21 seconds 18 - 21 seconds Gravity gun nozzle HVLP 1.5 - 1.7 mm 1.5 - 1.7 mm Spray pressure HVLP at the cap 8 - 10 psi 8 - 10 psi Application 2 - 3 medium wet coats 2 - 3 medium wet coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 3.0 mils Coverage 532 sq. ft./gal @ 1.0 mil 604 sq. ft./gal @ 1.0 mil 68°F/20°C 60 minutes with LH810; 1.5 - 2 hours with LH820 90 minutes with LH810; 2.5 hours with LH820 140°F/60°C 20 minutes 20 minutes Infra red short wave N/A N/A Infra red medium wave N/A N/A Wet by Hand 320 - 400 grit 320 - 400 grit Dry by Hand 400 grit 400 grit Dry by Machine 320 - 400 grit 320 - 400 grit VOC as packaged 577 gms/liter (4.78 lbs/gal) 577 gms/liter (4.78 lbs/gal) VOC as applied 515 gms/liter (4.3 lbs/gal) 481 gms/liter (4.0 lbs/gal) Drying: Sanding: Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S 800K 2K Primer Surfacer Primer Surfacer Application with LHF, LHM, LHS Description: Limco 800K 2K Primer Surfacer is a very fast curing, easy sanding primer, that provides good sand scratch filling, no settling in the can, excellent adhesion and topcoat holdout. Materials: Primer Surfacer: 800K Hardeners: LHF LHM LHS Reducers: LR10 LR11 LR12 LR13 LR15 Flex Agent: 892 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat) R-M 902 Plastic Prep-Cleaner 220 grit R-M 902 Plastic Prep-Cleaner NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: US. Rev. 11/21/14 Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. T E C H N I C A L D A T A 800K 2K Primer Surfacer Primer Surfacer Application with LHF, LHM, LHS Flexed S Mixing ratio: 8:1:1 8:2:1:1 Primer 8 parts 800K 8 parts 800K Hardener 1 part LHF, LHM or LHS 2 parts LHF, LHM or LHS Reducer 1 part LR10, LR11, LR12, LR13 or LR15 1 part LR10, LR11, LR12, LR13 or LR15 Flex Agent — 1 part 892 Potlife at 68°F/20°C 30 minutes 30 minutes Spray viscosity Ford #4 @ 68°F/20°C 18 - 21 seconds 18 - 21 seconds Gravity gun nozzle HVLP 1.5 - 1.7 mm 1.5 - 1.7 mm Spray pressure HVLP at the cap 8 - 10 psi 8 - 10 psi Application 2 - 3 medium wet coats 2 - 3 medium wet coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 3.0 mils Coverage 308 sq. ft./gal @ 2.0 mils 325 sq. ft./gal @ 2.0 mils 68°F/20°C 60 minutes with LHF; 1.5 - 2 hours with LHS 90 minutes with LHF; 2.5 hours with LHS 140°F/60°C 20 minutes 20 minutes Infra red short wave N/A N/A Infra red medium wave N/A N/A Wet by Hand 320 - 400 grit 320 - 400 grit Dry by Hand 400 grit 400 grit Dry by Machine 320 - 400 grit 320 - 400 grit VOC as packaged 577 gms/liter (4.78 lbs/gal) 577 gms/liter (4.78 lbs/gal) VOC as applied 540 gms/liter (4.5 lbs/gal) 515 gms/liter (4.3 lbs/gal) Drying: Sanding: Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S 800K 2K Primer Surfacer Tinted Wet-On-Wet Sealer Application with LH810, LH820 Description: Limco 800K 2K as a tinted wet-on-wet sealer is a very fast drying sealer that provides excellent adhesion with good topcoat color holdout. Materials: Primer Sealer: 800K Limco Bases *: LB Bases Quick Mix Colors: Q Bases Hardeners: LH810 LH820 Reducers: LR21 LR25 Flex Agent: 892 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat) R-M 902 Plastic Prep-Cleaner 220 grit R-M 902 Plastic Prep-Cleaner NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. * LA bases cannot be used to tint 800K due to VOC compliance issues. US. Rev. 11/21/14 T E C H N I C A L D A T A 800K 2K Primer Surfacer Tinted Wet-On-Wet Sealer Application with LH810, LH820 Flexed S Mixing ratio: Step 1 - 1:1 Step 1 - 1:1 Primer 1 part 800K 1 part 800K Base 1 part LB Base (without mixing clear) 1 part LB Base (without mixing clear) Step 2 - 4:1:1 4 parts 800K / LB Base mixture Step 2 - 4:1:1:1 4 parts 800K / LB Base mixture Hardener 1 part LH810 or LH820 1 part LH810 or LH820 Reducer 1 part LR21 or LR25 1 part LR21 or LR25 Flex Agent — 1 part 892 Potlife at 68°F/20°C 8 hours 8 hours Spray viscosity Ford #4 @ 68°F/20°C 13 - 15 seconds 13 - 15 seconds Gravity gun nozzle HVLP 1.5 - 1.7 mm 1.5 - 1.7 mm Spray pressure HVLP at the cap 8 - 10 psi 8 - 10 psi Application 1 medium wet coat 1 medium wet coat Flash-off time @ 68°F/20°C 15 - 30 minutes 15 - 30 minutes Film build 0.5 - 1.5 mils 0.5 - 1.5 mils Coverage 531 sq. ft./gal @ 1.0 mil 602 sq. ft./gal @ 1.0 mil 68°F/20°C 15 - 30 minutes 15 - 30 minutes 140°F/60°C N/A N/A Infra red short wave N/A N/A Infra red medium wave N/A N/A Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged 577 gms/liter (4.78 lbs/gal) 577 gms/liter (4.78 lbs/gal) VOC as applied 433 gms/liter (3.6 lbs/gal) 398 gms/liter (3.3 lbs/gal) Drying: Sanding: Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S 800K 2K Primer Surfacer Tinted Wet-On-Wet Sealer Application with LHF, LHM, LHS Description: Limco 800K 2K as a tinted wet-on-wet sealer is a very fast drying sealer that provides excellent adhesion with good topcoat color holdout. Materials: Primer Sealer: 800K Limco Bases *: LB Bases Quick Mix Colors: Q Bases Hardeners: LHF LHM LHS Reducers: LR21 LR25 Flex Agent: 892 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat R-M 902 Plastic Prep-Cleaner 220 grit R-M 902 Plastic Prep-Cleaner NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. * LA bases cannot be used to tint 800K due to VOC compliance issues. US. Rev. 11/21/14 T E C H N I C A L D A T A 800K 2K Primer Surfacer Tinted Wet-On-Wet Sealer Application with LHF, LHM, LHS Flexed S Mixing ratio: Step 1 - 1:1 Step 1 - 1:1 Primer 1 part 800K 1 part 800K Base 1 part LB Base (without mixing clear) 1 part LB Base (without mixing clear) Step 2 - 4:1:1 4 parts 800K / LB Base mixture Step 2 - 4:1:1:1 4 parts 800K / LB Base mixture Hardener 1 part LHF, LHM or LHS 1 part LHF, LHM or LHS Reducer 1 part LR21 or LR25 1 part LR21 or LR25 Flex Agent — 1 part 892 Potlife at 68°F/20°C 8 hours 8 hours Spray viscosity Ford #4 @ 68°F/20°C 13 - 15 seconds 13 - 15 seconds Gravity gun nozzle HVLP 1.5 - 1.7 mm 1.5 - 1.7 mm Spray pressure HVLP at the cap 8 - 10 psi 8 - 10 psi Application 1 medium wet coat 1 medium wet coat Flash-off time @ 68°F/20°C 15 - 30 minutes 15 - 30 minutes Film build 0.5 - 1.5 mils 0.5 - 1.5 mils Coverage 631 sq. ft./gal @ 1.0 mil 689 sq. ft./gal @ 1.0 mil 68°F/20°C 15 - 30 minutes 15 - 30 minutes 140°F/60°C N/A N/A Infra red short wave N/A N/A Infra red medium wave N/A N/A Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged 577 gms/liter (4.78 lbs/gal) 577 gms/liter (4.78 lbs/gal) VOC as applied 455 gms/liter (3.8 lbs/gal) 420 gms/liter (3.6 lbs/gal) Drying: Sanding: Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S 846 1K Acrylic Primer Primer Surfacer Application Description: Limco 846 1K Acrylic Primer is a non-settling, fast drying, easy sanding, flexible primer that meets the U.S. National Rule and provides excellent adhesion plus good color hold-out. Materials: Primer: 846 Reducers: LR21 LR25 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat) R-M 902 Plastic Prep-Cleaner 220 grit R-M 902 Plastic Prep-Cleaner NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. 846 is a high filling, fast sanding 1K lacquer primer. Best results are obtained when thinner coats, with 5 - 10 minutes flash between coats, are observed. Excessive film builds of lacquer primer can lead to soft topcoats or premature film failures. US. Rev. 11/21/14 T E C H N I C A L D A T A 846 1K Acrylic Primer Primer Surfacer Application S Mixing ratio: 1:1 Primer 1 part 846 Reducer 1 part LR21 or LR25 Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 12 - 15 seconds Gravity gun nozzle HVLP 1.5 mm Spray pressure HVLP at the cap 10 psi Application 2 - 3 medium wet coats Flash-off time @ 68°F/20°C 5 - 10 minutes Film build 2.0 - 3.0 mils Coverage 203 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 20 minutes 140°F/60°C N/A Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand 320 grit Dry by Machine 280 grit VOC as packaged 550 gms/liter (4.6 lbs/gal) VOC as applied 550 gms/liter (4.6 lbs/gal) Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S H1000 1K Waterborne Primer Primer Surfacer Application Description: Limco H1000 1K Waterborne Primer is a grey, 1K Low VOC Waterborne System that is fast drying, easy sanding and provides excellent adhesion with good color holdout. Materials: Primer Surfacer: H1000 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe O.E.M. primed spare parts R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe Bare steel R-M 909 Final Wipe 80 - 180 grit R-M 909 Final Wipe Galvanized Steel R-M 909 Final Wipe Then, pre-prime with LP20 Coarse scuff pad R-M 909 Final Wipe Aluminum R-M 909 Final Wipe Then, pre-prime with LP20 120 - 180 grit R-M 909 Final Wipe Fiberglass plastic parts (without gelcoat) R-M 909 Final Wipe 220 grit R-M 909 Final Wipe NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Low VOC Urethane (Limco 3) 420 gms/liter (3.5 lbs/gal) VOC Limco Low VOC Industrial Urethane Single Stage (Limco 7) 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Shelf Life - 12 months Keep from freezing. Store at temperatures 40°F - 105°F / 5°C - 40°C. Dry sand only. DO NOT wet sand H1000 1K Waterborne Primer. US. Rev. 11/21/14 T E C H N I C A L D A T A H1000 1K Waterborne Primer Primer Surfacer Application S Mixing ratio: Ready for use Primer H1000 Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 14 - 16 seconds Gravity gun nozzle HVLP 1.5 mm Spray pressure HVLP at the cap 10 psi Application 2 - 3 coats Flash-off time @ 68°F/20°C 5 - 10 minutes between coats Film build 2.0 - 3.0 mils Coverage 327 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 30 minutes 140°F/60°C N/A Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand 320 grit Dry by Machine 280 grit VOC as packaged 75 gms/liter (0.6 lbs/gal) VOC as applied 75 gms/liter (0.6 lbs/gal) Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP20 Epoxy Primer Primer Application Description: Limco LP20 Epoxy Primer is a two part epoxy primer for use as a primer under 800K, 846, PS21nr, LS800 or LS56. LP20 offers excellent adhesion and corrosion protection when used over steel, aluminum, zinc coated or galvanized metals. LP20 can be applied over cured, cleaned and sanded paint finishes (except acrylic lacquers). Materials: Primer: LP20 Activator: LA20 Reducer: LR21 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat) LP20 is not recommended over this substrate NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: US. Rev. 11/21/14 Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. T E C H N I C A L D A T A LP20 Epoxy Primer Primer Application S Mixing ratio: 3:1:1 Primer 3 parts LP20 Activator 1 part LA20 Reducer 1 part LR21 Potlife at 68°F/20°C 8 hours Spray viscosity Ford #4 @ 68°F/20°C 12 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi Application 1 - 2 light coats Flash-off time @ 68°F/20°C 5 - 10 minutes between coats Film build 0.5 - 0.75 mils Coverage 970 - 1038 sq. ft./gal @ 0.5 mil Drying: 68°F/20°C 15 - 30 minutes 140°F/60°C N/A Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged 515 gms/liter (4.3 lbs/gal) VOC as applied 312 gms/liter (2.6 lbs/gal) Comments Do not use over flexible parts. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP20 Epoxy Primer Low VOC Primer Application Description: LP20 Epoxy Primer is a two part epoxy primer for use as a primer under H1000, LP610 or LP620. LP20 offers excellent adhesion and corrosion protection when used over steel, aluminum, zinc coated or galvanized metals. LP20 can be applied over cured, cleaned and sanded paint finishes (except acrylic lacquers). Materials: Primer: LP20 Activator: LA25 Reducer: LR21 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe O.E.M. primed spare parts R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe Bare steel R-M 909 Final Wipe 80 - 180 grit R-M 909 Final Wipe Galvanized Steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe Aluminum R-M 909 Final Wipe 120 - 180 grit R-M 909 Final Wipe Fiberglass plastic parts (without gelcoat) LP20 is not recommended over this substrate NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Low VOC Urethane (Limco 3) 420 gms/liter (3.5 lbs/gal) VOC Limco Low VOC Industrial Urethane Single Stage (Limco 7) 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC Remarks: US. Rev. 11/21/14 Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. T E C H N I C A L D A T A LP20 Epoxy Primer Low VOC Primer Application S Mixing ratio: 4:1:1 Primer 4 parts LP20 Activator 1 part LA25 Reducer 1 part LR21 Potlife at 68°F/20°C 8 hours Spray viscosity Ford #4 @ 68°F/20°C 12 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi Application 1 - 2 light coats Flash-off time @ 68°F/20°C 5 - 10 minutes between coats Film build 0.5 - 0.75 mils Coverage 970 - 1038 sq. ft./gal @ 0.5 mil Drying: 68°F/20°C 15 - 30 minutes 140°F/60°C N/A Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged 515 gms/liter (4.3 lbs/gal) VOC as applied 211 gms/liter (1.7 lbs/gal) Comments Do not use over flexible parts. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP20 Epoxy Primer Primer Surfacer Application Description: Limco LP20 Epoxy Primer is a two part epoxy primer for use as a Primer Surfacer. LP20 offers excellent adhesion and corrosion protection when used over steel, aluminum, zinc coated or galvanized metals. LP20 can be applied over cured, cleaned and sanded paint finishes (except acrylic lacquers). Materials: Primer Surfacer: LP20 Activator: LA20 Reducer: LR21 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat) LP20 is not recommended over this substrate NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: US. Rev. 11/21/14 Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. T E C H N I C A L D A T A LP20 Epoxy Primer Primer Surfacer Application S Mixing ratio: 3:1:1 Primer 3 parts LP20 Activator 1 part LA20 Reducer 1 part LR21 Potlife at 68°F/20°C 8 hours Spray viscosity Ford #4 @ 68°F/20°C 12 seconds Gravity gun nozzle HVLP 1.5 - 1.8 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 medium coats Flash-off time @ 68°F/20°C 5 - 10 minutes between coats Film build 2.0 - 2.5 mils Coverage 344 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 3 hours 140°F/60°C 30 - 35 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand 400 - 600 grit Dry by Hand 320 - 400 grit Dry by Machine 320 - 400 grit VOC as packaged 515 gms/liter (4.3 lbs/gal) VOC as applied 312 gms/liter (2.6 lbs/gal) Comments Do not use over flexible parts. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP20 Epoxy Primer Low VOC Primer Surfacer Application Description: Limco LP20 Epoxy Primer is a two part epoxy primer for use as a Primer Surfacer. LP20 offers excellent adhesion and corrosion protection when used over steel, aluminum, zinc coated or galvanized metals. LP20 can be applied over cured, cleaned and sanded paint finishes (except acrylic lacquers). Materials: Primer Surfacer: LP20 Activator: LA25 Reducer: LR21 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe O.E.M. primed spare parts R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe Bare steel R-M 909 Final Wipe 80 - 180 grit R-M 909 Final Wipe Galvanized Steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe Aluminum R-M 909 Final Wipe 120 - 180 grit R-M 909 Final Wipe Fiberglass plastic parts (without gelcoat) LP20 is not recommended over this substrate NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Low VOC Urethane (Limco 3) 420 gms/liter (3.5 lbs/gal) VOC Limco Low VOC Industrial Urethane Single Stage (Limco 7) 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC Remarks: US. Rev. 11/21/14 Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. T E C H N I C A L D A T A LP20 Epoxy Primer Low VOC Primer Surfacer Application S Mixing ratio: 4:1:1 Primer 4 parts LP20 Activator 1 part LA25 Reducer 1 part LR21 Potlife at 68°F/20°C 8 hours Spray viscosity Ford #4 @ 68°F/20°C 20 seconds Gravity gun nozzle HVLP 1.5 - 1.8 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 medium coats Flash-off time @ 68°F/20°C 5 - 10 minutes between coats Film build 2.0 - 2.5 mils Coverage 381 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 6 hours 140°F/60°C 30 - 35 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand 400 - 600 grit Dry by Hand 320 - 400 grit Dry by Machine 320 - 400 grit VOC as packaged 515 gms/liter (4.3 lbs/gal) VOC as applied 211 gms/liter (1.7 lbs/gal) Comments Do not use over flexible parts. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP20 Epoxy Primer Wet-On-Wet Sealer Application Description: Limco LP20 Epoxy Primer is a two part epoxy primer for use as a wet-on-wet sealer under Limco topcoats. LP20 can be applied over cured, cleaned and sanded paint finishes (except acrylic lacquers). Materials: Sealer: LP20 Activator: LA20 Reducer: LR21 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat) LP20 is not recommended over this substrate NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: US. Rev. 11/21/14 Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. T E C H N I C A L D A T A LP20 Epoxy Primer Wet-On-Wet Sealer Application S Untinted Tinted with LB Bases Tinted with LA Bases Mixing ratio: 3:1:1 3:1:1:1 3:1:1:1 Primer 3 parts LP20 3 parts LP20 3 parts LP20 Base – 1 part LB Base 1 part LA Base Activator 1 part LA20 1 part LA20 1 part LA20 Reducer 1 part LR21 1 part LR21 1 part LR21 Potlife at 68°F/20°C 8 hours 8 hours 8 hours Spray viscosity Ford #4 @ 68°F/20°C 12 seconds 12 seconds 12 seconds Gravity gun nozzle HVLP 1.5 - 1.8 mm 1.5 - 1.8 mm 1.5 - 1.8 mm Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi 6 - 10 psi Application 1 medium wet coat or 2 light coats 1 medium wet coat or 2 light coats 1 medium wet coat or 2 light coats Flash-off time @ 68°F/20°C 5 - 10 minutes between coats 5 - 10 minutes between coats 5 - 10 minutes between coats Film build 0.75 - 1.3 mils 0.75 - 1.3 mils 0.75 - 1.3 mils Coverage 688 sq. ft./gal @ 1.0 mil 696 sq. ft./gal @ 1.0 mil 702 sq. ft./gal @ 1.0 mil 68°F/20°C 45 minutes before topcoating with Limco 45 minutes before topcoating with Limco 45 minutes before topcoating with Limco 140°F/60°C N/A N/A N/A Infra red short wave N/A N/A N/A Infra red medium wave N/A N/A N/A Wet by Hand N/A N/A N/A Dry by Hand N/A N/A N/A Dry by Machine N/A N/A N/A VOC as packaged 515 gms/liter (4.3 lbs/gal) 515 gms/liter (4.3 lbs/gal) 515 gms/liter (4.3 lbs/gal) VOC as applied 312 gms/liter (2.6 lbs/gal) 338 gms/liter (2.8 lbs/gal) 357 gms/liter (3.0 lbs/gal) Comments Do not use over flexible parts. Drying: Sanding: Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP20 Epoxy Primer Low VOC Wet-On-Wet Sealer Application Description: Limco LP20 Epoxy Primer is a two part epoxy primer for use as a wet-on-wet sealer under Limco topcoats. LP20 can be applied over cured, cleaned and sanded paint finishes (except acrylic lacquers). Materials: Sealer: LP20 Activator: LA25 Reducer: LR21 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe O.E.M. primed spare parts R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe Bare steel R-M 909 Final Wipe 80 - 180 grit R-M 909 Final Wipe Galvanized Steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe Aluminum R-M 909 Final Wipe 120 - 180 grit R-M 909 Final Wipe Fiberglass plastic parts (without gelcoat) LP20 is not recommended over this substrate NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Low VOC Urethane (Limco 3) 420 gms/liter (3.5 lbs/gal) VOC Limco Low VOC Industrial Urethane Single Stage (Limco 7) 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC Remarks: US. Rev. 11/21/14 Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. T E C H N I C A L D A T A LP20 Epoxy Primer Low VOC Wet-On-Wet Sealer Application S Untinted Tinted with LB Bases Tinted with LA Bases Mixing ratio: 4:1:1 4:1:1:1 4:1:1:1 Primer 4 parts LP20 4 parts LP20 4 parts LP20 Base – 1 part LB Base 1 part LA Base Activator 1 part LA25 1 part LA25 1 part LA25 Reducer 1 part LR21 1 part LR21 1 part LR21 Potlife at 68°F/20°C 8 hours 8 hours 8 hours Spray viscosity Ford #4 @ 68°F/20°C 12 seconds 12 seconds 12 seconds Gravity gun nozzle HVLP 1.5 - 1.8 mm 1.5 - 1.8 mm 1.5 - 1.8 mm Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi 6 - 10 psi Application 1 medium wet coat or 2 light coats 1 medium wet coat or 2 light coats 1 medium wet coat or 2 light coats Flash-off time @ 68°F/20°C 5 - 10 minutes between coats 5 - 10 minutes between coats 5 - 10 minutes between coats Film build 0.75 - 1.3 mils 0.75 - 1.3 mils 0.75 - 1.3 mils Coverage 762 sq. ft./gal @ 1.0 mil 762 sq. ft./gal @ 1.0 mil 762 sq. ft./gal @ 1.0 mil 68°F/20°C 45 minutes before topcoating with Limco 45 minutes before topcoating with Limco 45 minutes before topcoating with Limco 140°F/60°C N/A N/A N/A Infra red short wave N/A N/A N/A Infra red medium wave N/A N/A N/A Wet by Hand N/A N/A N/A Dry by Hand N/A N/A N/A Dry by Machine N/A N/A N/A VOC as packaged 515 gms/liter (4.3 lbs/gal) 515 gms/liter (4.3 lbs/gal) 515 gms/liter (4.3 lbs/gal) VOC as applied 211 gms/liter (1.7 lbs/gal) 262 gms/liter (2.2 lbs/gal) 285 gms/liter (2.4 lbs/gal) Comments Do not use over flexible parts. Drying: Sanding: Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP100 Etch Primer Primer Application Description: Limco LP100 Etch Primer is chromate free and has excellent adhesion properties that work equally well on steel, aluminum and galvanized steel. When applied over bare steel, LP100 is an effective rust inhibitor. Limco LP100 can be primed over with any approved Limco undercoat except H1000. Limco LP100 should also not be used under waterborne primers or peroxide-cured body fillers. Materials: Primer: LP100 Activator: LPA100 Reducers: LR10 LR11 LR12 LR13 LR15 Substrate/Pretreatment: Cleaning Well cured old paint work LP100 is not recommended over this substrate Sanding Second Cleaning O.E.M. primed spare parts LP100 is not recommended over this substrate Bare steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Galvanized steel 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat) LP100 is not recommended over this substrate NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: A topcoat can not be applied directly over LP100. Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. US. Rev. 11/21/14 T E C H N I C A L D A T A LP100 Etch Primer Primer Application S Mixing ratio: 1:1:50% Primer 1 part LP100 Activator 1 part LPA100 Reducer 50% LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 12 - 13 seconds Gravity gun nozzle HVLP 1.5 mm Spray pressure HVLP at the cap 8 - 10 psi Application 1 medium wet coat or 2 light coats Flash-off time @ 68°F/20°C 5 - 10 minutes Film build 0.5 - 1.5 mil Coverage 171 sq. ft./gal @ 1.0 mil Drying: 68°F/20°C 15 minutes 140°F/60°C N/A Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged 460 gms/liter (3.84 lbs/gal) VOC as applied 697 - 770 gms/liter (5.8 - 6.4 lbs/gal) Comments Appropriate undercoat must be applied on top of LP100 within 4 hours of application. This product may be reduced up to 150%. Higher reduction will alter viscosity, film build per coat and square foot coverage. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP100 Etch Primer Low VOC Primer Application Description: Limco LP100 Etch Primer is chromate free and has excellent adhesion properties that work equally well on steel, aluminum and galvanized steel. When applied over bare steel, LP100 is an effective rust inhibitor. Limco LP100 can be primed over with any approved Limco undercoat except H1000. Limco LP100 should also not be used under waterborne primers or peroxide-cured body fillers. Materials: Primer: LP100 Activator: LPA100 Reducers: LR21 LR25 Substrate/Pretreatment: Cleaning Well cured old paint work LP100 is not recommended over this substrate Sanding Second Cleaning O.E.M. primed spare parts LP100 is not recommended over this substrate Bare steel R-M 909 Final Wipe 80 - 180 grit R-M 909 Final Wipe Galvanized steel R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe Aluminum R-M 909 Final Wipe 120 - 180 grit R-M 909 Final Wipe Fiberglass plastic parts (without gelcoat) LP100 is not recommended over this substrate NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: A topcoat can not be applied directly over LP100. Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. US. Rev. 11/21/14 T E C H N I C A L D A T A LP100 Etch Primer Low VOC Primer Application S Mixing ratio: 1:1:150% Primer 1 part LP100 Activator 1 part LPA100 Reducer 150% LR21 or LR25 Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 10 - 11 seconds Gravity gun nozzle HVLP 1.5 mm Spray pressure HVLP at the cap 8 - 10 psi Application 1 medium wet coat or 2 light coats Flash-off time @ 68°F/20°C 5 - 10 minutes Film build 0.5 - 1.5 mil Coverage 122 sq. ft./gal @ 1.0 mil Drying: 68°F/20°C 15 minutes 140°F/60°C N/A Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged 460 gms/liter (3.84 lbs/gal) VOC as applied 612 gms/liter (5.1 lbs/gal) Comments Appropriate undercoat must be applied on top of LP100 within 4 hours of application. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP610 Low VOC Primer Low VOC Primer Surfacer Application Description: Limco LP610 Low VOC Primer is a quick cure, sandable primer that provides good sand scratch filling with excellent adhesion and topcoat holdout. It is a 2.1 VOC compliant performance primer that provides good filling properties. Materials: Primer: LP610 Hardeners: LH401 LH405 LH415 Reducers: LR21 LR25 Flex Agent: 892 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe O.E.M. primed spare parts R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe Bare steel R-M 909 Final Wipe Then, pre-prime with LP20 or LP100 80 - 180 grit R-M 909 Final Wipe Galvanized Steel R-M 909 Final Wipe Then, pre-prime with LP20 or LP100 Coarse scuff pad R-M 909 Final Wipe Aluminum R-M 909 Final Wipe Then, pre-prime with LP20 or LP100 120 - 180 grit R-M 909 Final Wipe Fiberglass plastic parts (without gelcoat) R-M 909 Final Wipe 220 grit R-M 909 Final Wipe NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Low VOC Urethane (Limco 3) 420 gms/liter (3.5 lbs/gal) VOC Limco Low VOC Industrial Urethane Single Stage (Limco 7) 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Use an adhesion promoter when refinishing raw plastic parts. US. Rev. 2/5/15 T E C H N I C A L D A T A LP610 Low VOC Primer Low VOC Primer Surfacer Application Flexed Mixing ratio: Primer S 8:1:2 4:1:1:1 8 parts LP610 4 parts LP610 Flex Agent — 1 part 892 Hardener 1 part LH401, LH405 or LH415 1 part LH401, LH405 or LH415 Reducer 2 parts LR21 or LR25 1 part LR21 or LR25 Potlife at 68°F/20°C 30 - 45 minutes 30 - 45 minutes Spray viscosity Ford #4 @ 68°F/20°C 13 - 18 seconds 15 - 19 seconds Gravity gun nozzle HVLP 1.5 - 1.7 mm 1.5 - 1.7 mm Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi Application 2 - 3 medium wet coats 2 - 3 medium wet coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 mils total dry film build 2.0 mils total dry film build Coverage 336 sq. ft./gal @ 2.0 mils 379 sq. ft./gal @ 2.0 mils 68°F/20°C 60 - 90 minutes 90 - 120 minutes 140°F/60°C 30 minutes; allow 10 minutes flash before force dry 30 minutes; allow 10 minutes flash before force dry Infra red short wave 5 - 7 minutes 6 - 8 minutes Infra red medium wave N/A N/A Wet by Hand 400 grit 400 grit Dry by Hand 320 grit 320 grit Dry by Machine 320 grit 320 grit VOC as packaged 222 gms/liter (1.8 lbs/gal) 222 gms/liter (1.8 lbs/gal) VOC as applied 231 gms/liter (1.9 lbs/gal) 250 gms/liter (2.1 lbs/gal) Drying: Sanding: Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP610 Low VOC Primer Low VOC Sealer Application Description: Limco LP610 Low VOC Primer is a quick cure, sandable primer that provides good sand scratch filling with excellent adhesion and topcoat holdout. It is a 2.1 VOC compliant performance primer that provides good filling properties. Materials: Primer: LP610 Hardeners: LH401 LH405 LH415 Reducers: LR21 LR25 Flex Agent: 892 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe O.E.M. primed spare parts R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe Bare steel R-M 909 Final Wipe Then, pre-prime with LP20 or LP100 80 - 180 grit R-M 909 Final Wipe Galvanized Steel R-M 909 Final Wipe Then, pre-prime with LP20 or LP100 Coarse scuff pad R-M 909 Final Wipe Aluminum R-M 909 Final Wipe Then, pre-prime with LP20 or LP100 120 - 180 grit R-M 909 Final Wipe Fiberglass plastic parts (without gelcoat) R-M 909 Final Wipe 220 grit R-M 909 Final Wipe NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Low VOC Urethane (Limco 3) 420 gms/liter (3.5 lbs/gal) VOC Limco Low VOC Industrial Urethane Single Stage (Limco 7) 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Use an adhesion promoter when refinishing raw plastic parts. US. Rev. 2/5/15 T E C H N I C A L D A T A LP610 Low VOC Primer Low VOC Sealer Application Flexed Mixing ratio: Primer S 8:1:4 4:1:1:2 8 parts LP610 4 parts LP610 Flex Agent — 1 part 892 Hardener 1 part LH401, LH405 or LH415 1 part LH401, LH405 or LH415 Reducer 4 parts LR21 or LR25 2 parts LR21 or LR25 Potlife at 68°F/20°C 45 - 60 minutes 30 - 45 minutes Spray viscosity Ford #4 @ 68°F/20°C 12 - 15 seconds 13 - 16 seconds Gravity gun nozzle HVLP 1.5 mm 1.5 - 1.6 mm Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi Application 2 - 3 medium wet coats 1 - 2 medium wet coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 1.0 - 1.5 mils total dry film build 1.0 - 1.5 mils total dry film build Coverage 437 sq. ft./gal @ 1.0 mils 331 sq. ft./gal @ 2.0 mils 68°F/20°C 30 minutes flash before topcoating 30 minutes flash before topcoating 140°F/60°C N/A N/A Infra red short wave N/A N/A Infra red medium wave N/A N/A Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged 222 gms/liter (1.8 lbs/gal) 222 gms/liter (1.8 lbs/gal) VOC as applied 231 gms/liter (1.9 lbs/gal) 250 gms/liter (2.1 lbs/gal) Drying: Sanding: Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP620 Low VOC Primer Primer Surfacer Application Description: Limco LP620 Low VOC Primer in this National Rule presentation is a quick cure, sandable primer that provides good sand scratch filling with excellent adhesion and topcoat holdout. It is a National Rule compliant performance primer that provides good filling properties. Materials: Primer: LP620 Hardeners: LHF LHM LHS Reducers: LR10 LR11 LR12 LR13 LR15 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat) R-M 902 Plastic Prep-Cleaner 220 grit R-M 902 Plastic Prep-Cleaner NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Use an adhesion promoter when refinishing raw plastic parts. US. Rev. 8/4/15 T E C H N I C A L D A T A LP620 Low VOC Primer Primer Surfacer Application Mixing ratio: S 4:1:1 Primer 4 parts LP620 Hardener 1 part LHF, LHM or LHS Reducer 1 part LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C 45 minutes Spray viscosity Ford #4 @ 68°F/20°C 16 - 20 seconds Gravity gun nozzle HVLP 1.5 - 1.7 mm Spray pressure HVLP at the cap 6 - 10 psi Application 1 - 2 medium wet coats Flash-off time @ 68°F/20°C 5 minutes Film build 2.0 - 3.0 mils total dry film build Coverage 723 sq. ft./gal @ 1.0 mil Drying: 68°F/20°C 60 - 90 minutes 140°F/60°C 30 - 40 minutes; allow 10 minutes flash before force drying. Infra red short wave 5 - 7 minutes Infra red medium wave N/A Sanding: Wet by Hand 400 grit Dry by Hand 320 grit Dry by Machine 320 grit VOC as packaged 222 gms/liter (1.8 lbs/gal) VOC as applied 330 gms/liter (2.8 lbs/gal) Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP620 Low VOC Primer Low VOC Primer Surfacer Application Description: Limco LP620 Low VOC Primer is a quick cure, sandable primer that provides good sand scratch filling with excellent adhesion and topcoat holdout. It is a 2.1 VOC compliant performance primer that provides good filling properties. Materials: Primer: LP620 Hardeners: LH401 LH405 LH415 Reducers: LR21 LR25 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe O.E.M. primed spare parts R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe Bare steel R-M 909 Final Wipe Then, pre-prime with LP20 or LP100 80 - 180 grit R-M 909 Final Wipe Galvanized Steel R-M 909 Final Wipe Then, pre-prime with LP20 or LP100 Coarse scuff pad R-M 909 Final Wipe Aluminum R-M 909 Final Wipe Then, pre-prime with LP20 or LP100 120 - 180 grit R-M 909 Final Wipe Fiberglass plastic parts (without gelcoat) R-M 909 Final Wipe 220 grit R-M 909 Final Wipe NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Low VOC Urethane (Limco 3) 420 gms/liter (3.5 lbs/gal) VOC Limco Low VOC Industrial Urethane Single Stage (Limco 7) 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Use an adhesion promoter when refinishing raw plastic parts. US. Rev. 11/21/14 T E C H N I C A L D A T A LP620 Low VOC Primer Low VOC Primer Surfacer Application Mixing ratio: S 4:1:1 Primer 4 parts LP620 Hardener 1 part LH401, LH405 or LH415 Reducer 1 part LR21 or LR25 Potlife at 68°F/20°C 45 minutes Spray viscosity Ford #4 @ 68°F/20°C 16 - 20 seconds Gravity gun nozzle HVLP 1.5 - 1.7 mm Spray pressure HVLP at the cap 6 - 10 psi Application 1 - 2 medium wet coats Flash-off time @ 68°F/20°C 5 minutes Film build 2.0 - 3.0 mils total dry film build Coverage 719 sq. ft./gal @ 1.0 mil Drying: 68°F/20°C 60 - 90 minutes 140°F/60°C 30 - 40 minutes; allow 10 minutes flash before force drying. Infra red short wave 5 - 7 minutes Infra red medium wave N/A Sanding: Wet by Hand 400 grit Dry by Hand 320 grit Dry by Machine 320 grit VOC as packaged 222 gms/liter (1.8 lbs/gal) VOC as applied 238 gms/liter (1.9 lbs/gal) Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP620 Low VOC Primer Sealer Application Description: Limco LP620 Low VOC Primer in this National Rule presentation is a quick cure, sandable primer that provides good sand scratch filling with excellent adhesion and topcoat holdout. It is a National Rule compliant performance primer that provides good filling properties. Materials: Primer: LP620 Hardeners: LHF LHM LHS Reducers: LR10 LR11 LR12 LR13 LR15 Flex Agent: 892 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat) R-M 902 Plastic Prep-Cleaner 220 grit R-M 902 Plastic Prep-Cleaner NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Use an adhesion promoter when refinishing raw plastic parts. US. Rev. 8/4/15 T E C H N I C A L D A T A LP620 Low VOC Primer Sealer Application Flexed Mixing ratio: S Tinted 4:1:2 4:1:1:2 4:4:1:2 Primer 4 parts LP620 4 parts LP620 4 parts LP620 Color — — 4 parts LA Base Flex Agent — 1 part 892 — Hardener 1 part LHF, LHM or LHS 1 part LHF, LHM or LHS 1 part LHF, LHM or LHS Reducer 2 parts LR10, LR11, LR12, LR13 or LR15 2 parts LR10, LR11, LR12, LR13 or LR15 2 parts LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C 60 minutes 90 minutes 60 minutes Spray viscosity Ford #4 @ 68°F/20°C 13 - 16 seconds 13 - 16 seconds 13 - 16 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi 6 - 10 psi Application 1 medium wet coat 1 medium wet coat 1 medium wet coat Flash-off time @ 68°F/20°C N/A N/A N/A Film build 1.0 - 1.5 mils total dry film build 1.0 - 1.5 mils total dry film build 1.0 - 1.5 mils total dry film build Coverage 620 sq. ft./gal @ 1.0 mil 671 sq. ft./gal @ 1.0 mil 608 sq. ft./gal @ 1.0 mil 140°F/60°C 30 minutes flash before topcoating N/A 30 minutes flash before topcoating N/A 30 minutes flash before topcoating N/A Infra red short wave N/A N/A N/A Infra red medium wave N/A N/A N/A Wet by Hand N/A N/A N/A Dry by Hand N/A N/A N/A Dry by Machine N/A N/A N/A VOC as packaged 222 gms/liter (1.8 lbs/gal) 222 gms/liter (1.8 lbs/gal) 222 gms/liter (1.8 lbs/gal) VOC as applied 470 gms/liter (4.0 lbs/gal) 430 gms/liter (3.6 lbs/gal) 495 gms/liter (4.2 lbs/gal) Drying: 68°F/20°C Sanding: Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LP620 Low VOC Primer Low VOC Sealer Application Description: Limco LP620 Low VOC Primer is a 2.1 VOC compliant performance sealer that provides good filling properties and quick drying with good melt-in and topcoat holdout.. Materials: Primer: LP620 Hardeners: LH401 LH405 LH415 Reducers: LR21 LR25 Flex Agent: 892 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe O.E.M. primed spare parts R-M 909 Final Wipe 240 - 400 grit R-M 909 Final Wipe Bare steel R-M 909 Final Wipe Then, pre-prime with LP20 or LP100 80 - 180 grit R-M 909 Final Wipe Galvanized Steel R-M 909 Final Wipe Then, pre-prime with LP20 or LP100 Coarse scuff pad R-M 909 Final Wipe Aluminum R-M 909 Final Wipe Then, pre-prime with LP20 or LP100 120 - 180 grit R-M 909 Final Wipe Fiberglass plastic parts (without gelcoat) R-M 909 Final Wipe 220 grit R-M 909 Final Wipe NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Low VOC Urethane (Limco 3) 420 gms/liter (3.5 lbs/gal) VOC Limco Low VOC Industrial Urethane Single Stage (Limco 7) 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Use an adhesion promoter when refinishing raw plastic parts. US. Rev. 11/21/14 T E C H N I C A L D A T A LP620 Low VOC Primer Low VOC Sealer Application Flexed Mixing ratio: Primer S 4:1:2 4:1:1:2 4 parts LP620 4 parts LP620 Flex Agent — 1 part 892 Hardener 1 part LH401, LH405 or LH415 1 part LH401, LH405 or LH415 Reducer 2 parts LR21 or LR25 2 parts LR21 or LR25 Potlife at 68°F/20°C 60 minutes 90 minutes Spray viscosity Ford #4 @ 68°F/20°C 13 - 16 seconds 13 - 16 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi Application 1 medium wet coat 1 medium wet coat Flash-off time @ 68°F/20°C N/A N/A Film build 1.0 - 1.5 mils total dry film build 1.0 - 1.5 mils total dry film build Coverage 616 sq. ft./gal @ 1.0 mil 668 sq. ft./gal @ 1.0 mil 68°F/20°C 30 minutes flash before topcoating 30 minutes flash before topcoating 140°F/60°C N/A N/A Infra red short wave N/A N/A Infra red medium wave N/A N/A Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged 222 gms/liter (1.8 lbs/gal) 222 gms/liter (1.8 lbs/gal) VOC as applied 240 gms/liter (2.0 lbs/gal) 236 gms/liter (2.0 lbs/gal) Drying: Sanding: Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LS56 1K Sealer Wet-On-Wet Sealer Application Description: Limco LS56 1K Sealer is a fast drying sealer that provides excellent adhesion with good topcoat color hold out. Materials: Sealer: LS56 Reducer: LR21 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover Then, Pre-prime with LP20 or LP100 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 120 - 180 grit 139 Final Wash Cleaner Fiberglass (with gelcoat) R-M 902 Plastic Prep-Cleaner 220 grit R-M 902 Plastic Prep-Cleaner NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: US. Rev. 11/21/14 Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. T E C H N I C A L D A T A LS56 1K Sealer Wet-On-Wet Sealer Application Mixing ratio: S 2:1 Sealer 2 parts LS56 Reducer 1 part LR21 Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 12 - 14 seconds Gravity gun nozzle HVLP 1.5 - 1.7 mm Spray pressure HVLP at the cap 8 - 10 psi Application 1 medium wet coat Flash-off time @ 68°F/20°C 30 minutes; 10 hours (max.) Film build 0.5 - 0.8 mils Coverage 825 sq. ft./gal @ 0.5 mil Drying: 68°F/20°C 30 minutes 140°F/60°C N/A Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged 545 gms/liter (4.6 lbs/gal) VOC as applied 550 gms/liter (4.6 lbs/gal) Comments Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S LS800 2K Sealer Wet-On-Wet Sealer Application Description: The LS800 2K Sealer is a tintable wet-on-wet sealer that dries quickly and provides excellent adhesion. LS800 2K Sealer can be tinted using either Limco LB bases or Limco Supreme LA bases. Materials: Sealer: LS800 Limco Bases: LB Bases Supreme Bases: LA Bases Hardeners: LHF LHM Reducers: LR10 LR11 LR12 LR13 Flex Agent: 892 Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat) R-M 902 Plastic Prep-Cleaner 220 grit R-M 902 Plastic Prep-Cleaner NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Do not use mixed color to tint LS800. Tint LS800 with LB bases or LA bases only. Do not force dry LS800, wet-on- wet application. US. Rev. 11/21/14 T E C H N I C A L D A T A LS800 2K Sealer Wet-On-Wet Sealer Application S Untinted Tinted with LB Bases Tinted with LA Bases Mixing ratio: 4:1:2 4:1:1:2 4:1:1:2 Primer 4 parts LS800 4 parts LS800 4 parts LS800 Base — 1 part LB Base 1 part LA Base Hardener 1 part LHF or LHM 1 part LHF or LHM 1 part LHF or LHM Reducer 2 parts LR10, LR11, LR12 or LR13 2 parts LR10, LR11, LR12 or LR13 2 parts LR10, LR11, LR12 or LR13 Potlife at 68°F/20°C 45 - 60 minutes 45 - 60 minutes 45 - 60 minutes Spray viscosity Ford #4 @ 68°F/20°C 13 - 15 seconds 13 - 15 seconds 13 - 15 seconds Gravity gun nozzle HVLP 1.4 - 1.5 mm 1.4 - 1.5 mm 1.4 - 1.5 mm Spray pressure HVLP at the cap 8 - 10 psi 8 - 10 psi 8 - 10 psi Application 1 - 2 medium wet coats 1 - 2 medium wet coats 1 - 2 medium wet coats Flash-off time @ 68°F/20°C 15 minutes 15 minutes 30 minutes Film build 1.0 - 1.5 mils 1.0 - 1.5 mils 1.0 - 1.5 mils Coverage 600 sq. ft./gal @ 1.0 mil 600 sq. ft./gal @ 1.0 mil 615 sq. ft./gal @ 1.0 mil 68°F/20°C 15 minutes (no longer than 3 hours before topcoat) 15 minutes (no longer than 3 hours before topcoat) 30 minutes (no longer than 4 hours before topcoat) 140°F/60°C N/A N/A N/A Infra red short wave N/A N/A N/A Infra red medium wave N/A N/A N/A Wet by Hand N/A N/A N/A Dry by Hand N/A N/A N/A Dry by Machine N/A N/A N/A VOC as packaged < 431 gms/liter (< 3.6 lbs/gal) < 431 gms/liter (< 3.6 lbs/gal) < 431 gms/liter (< 3.6 lbs/gal) VOC as applied < 550 gms/liter (< 4.6 lbs/gal) < 550 gms/liter (< 4.6 lbs/gal) < 550 gms/liter (< 4.6 lbs/gal) Comments For flexible plastic parts: Drying: Sanding: 4 parts LS800 1 part 892 1 additional part of hardener Then follow appropriate tinted or untinted mix ratio. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. U N D E R C O AT S PS21nr 1K Gray Sealer Wet-On-Wet Sealer Application Description: Limco PS21nr 1K Gray Sealer improves color hold-out and eliminates sand scratch swelling. This sealer is non-sanding, fast drying and ensures excellent adhesion. Materials: Sealer: Substrate/Pretreatment: Cleaning Sanding Second Cleaning Well cured old paint work 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner O.E.M. primed spare parts 203 Wax and Grease Remover 240 - 400 grit 139 Final Wash Cleaner Bare steel 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 80 - 180 grit 139 Final Wash Cleaner Galvanized Steel 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 Coarse scuff pad 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover Then, pre-prime with LP20 or LP100 120 - 180 grit 139 Final Wash Cleaner Fiberglass plastic parts (without gelcoat) PS21nr is not recommended under this substrate PS21nr NOTES: On Galvanized Steel and Aluminum, make sure sanding is not so vigorous that it removes the galvanized coating. With the second cleaning, make sure all residue is removed. Pay special attention when cleaning Galvanized Steel and Aluminum. Topcoats: Limco Synthetic Enamel (Limco 1) Limco Acrylic Enamel (Limco 2) Limco Urethane (Limco 3) Limco Basecoat (Limco 4) Supreme PLUS Acrylic 1K Single Stage Supreme PLUS Acrylic 2K Single Stage Supreme PLUS Urethane Single Stage Supreme PLUS Basecoat Remarks: US. Rev. 11/21/14 Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. T E C H N I C A L D A T A PS21nr 1K Gray Sealer Wet-ON-Wet Sealer Application Mixing ratio: Sealer S Ready for use PS21nr Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 13 seconds Gravity gun nozzle HVLP 1.5 mm Spray pressure HVLP at the cap 10 psi Application 1 - 2 light coats Flash-off time @ 68°F/20°C 5 to 10 minutes between coats Film build 0.5 - 1.0 mil Coverage 451 sq. ft./gal @ 1.0 mil Drying: 68°F/20°C 20 minutes 140°F/60°C N/A Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged 544 gms/liter (4.5 lbs/gal) VOC as applied 544 gms/liter (4.5 lbs/gal) Comments If allowed to dry overnight, sand with 400 grit then, clean with 139 Final Wash Cleaner to remove sanding residue prior to topcoating. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Limco Synthetic Enamel (Limco 1) U.S. National Rule VOC Description: Limco Synthetic Enamel is a superior development in automotive enamels for refinishing passenger cars, light trucks and commercial vehicles. It is a fast drying enamel providing fast film build, ease of application and a durable finish. Limco Synthetic Enamel is also available in Quick Mix colors. Materials: Limco Bases: LB Bases Quick Mix Colors: Q Bases Synthetic Enamel Mixing Clear: LMC1 Reducers: LR10 LR11 LR12 LR13 LR15 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 400 grit Primer Surfacer 800K 320 - 500 grit Primer Surfacer 846 320 - 500 grit Primer Surfacer LP20 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LS56 Sanding not required Primer Sealer LS800 Sanding not required Primer Sealer PS21nr Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Limco Synthetic Enamel (U.S. National Rule) colors, the color (LB, Q bases) must be mixed 2 parts to 1 part of LMC1 by volume prior to addition of reducer. US. Rev. 8/1/13 T E C H N I C A L D A T A Limco Synthetic Enamel (Limco 1) U.S. National Rule VOC S Mixing ratio: 4:1 Color 4 parts Color Reducer 1 part LR10, LR11, LR12, LR13 or LR15 (1) Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 18 - 20 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm Spray pressure HVLP at the cap 10 psi Application 2 - 3 coats Flash-off time @ 68°F/20°C 5 - 10 minutes between coats Film build 2.0 - 2.5 mils Coverage 235 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 30 minutes dust free; 8 hours to handle 140°F/60°C 35 minutes; allow 20 minutes flash before force dry Infra red short wave 10 - 15 minutes Infra red medium wave 35 minutes Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied 551 - 599 gms/liter (4.6 - 5.0 lbs/gal) Comments (1) LR15 is recommended for most high temperature conditions. LR15 will be used as a blend with LR13 (up to 50%). Wait 72 hours before sanding, compounding or recoating Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Limco Synthetic Enamel (Limco 1) with catalyst U.S. National Rule VOC Description: Limco Synthetic Enamel with catalyst adds improved gloss, shorter dry times and increased durability to the standard Limco Synthetic Enamel. Limco Synthetic Enamel is also available in Quick Mix colors. Materials: Limco Bases: LB Bases Quick Mix Colors: Q Bases Synthetic Enamel Mixing Clear: LMC1 Hardeners: LH100 LH130 Reducers: LR10 LR11 LR12 LR13 LR15 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 400 grit Primer Surfacer 800K 320 - 500 grit Primer Surfacer 846 320 - 500 grit Primer Surfacer LP20 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LS56 Sanding not required Primer Sealer LS800 Sanding not required Primer Sealer PS21nr Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Limco Synthetic Enamel with catalyst (U.S. National Rule) colors, the color (LB, Q bases) must be mixed 2 parts to 1 part of LMC1 by volume prior to addition of hardener and reducer. US. Rev. 8/1/13 T E C H N I C A L D A T A Limco Synthetic Enamel with catalyst (Limco 1) U.S. National Rule VOC S LH100 catalyst LH130 catalyst Mixing ratio: 8:1:4 4:1 Color 8 parts Color 4 parts Color Hardener 1 part LH100 1 part LH130 Reducer 4 parts LR10, LR11, LR12, LR13 or LR15 (1) — Potlife at 68°F/20°C 4 hours 2 hours Spray viscosity Ford #4 @ 68°F/20°C 15 - 18 seconds 18 - 20 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm Spray pressure HVLP at the cap 10 psi 10 psi Application 2 - 3 coats 2 - 3 coats Flash-off time @ 68°F/20°C 10 minutes 10 minutes Film build 2.0 - 2.5 mils 2.0 - 2.5 mils Coverage 251 sq. ft./gal @ 2.0 mils 277 sq. ft./gal @ 2.0 mils 68°F/20°C 30 minutes dust free; 8 hours to handle 30 minutes dust free; 8 hours to handle 140°F/60°C 30 minutes; allow 20 minutes flash before force dry 30 minutes; allow 20 minutes flash before force dry Infra red short wave 10 minutes 10 minutes Infra red medium wave 30 minutes 30 minutes Sanding: Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged Varies, dependent on color Varies, dependent on color VOC as applied < 599 gms/liter (< 5.0 lbs/gal) 539 - 587 lbs/gal (4.5 - 4.9 gms/liter) Comments (1) LR15 is recommended for most high temperature conditions. LR15 will be used as a blend with LR13 (up to 50%). Drying: Wait 24 hours before sanding, compounding or recoating. Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Limco Acrylic Enamel (Limco 2) U.S. National Rule VOC Description: Limco Acrylic Enamel is a specially formulated acrylic enamel with hardener which produces a superior high gloss durable finish. Limco Acrylic Enamel is also available in Quick Mix colors. Materials: Limco Bases: LB Bases Quick Mix Colors: Q Bases Acrylic Mixing Clear: LMC2 Hardeners: LHF LHM LHS Reducers: LR10 LR11 LR12 LR13 LR15 Flex Agent: 892 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 400 grit Primer Surfacer 800K 320 - 500 grit Primer Surfacer 846 320 - 500 grit Primer Surfacer LP20 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LS56 Sanding not required Primer Sealer LS800 Sanding not required Primer Sealer PS21nr Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Limco Acrylic Enamel (U.S. National Rule) colors, the color (LB, Q bases) must be mixed 2 parts to 1 part of LMC2 by volume prior to addition of hardener and reducer. US. Rev. 8/1/13 T E C H N I C A L D A T A Limco Acrylic Enamel (Limco 2) U.S. National Rule VOC Flexed S Mixing ratio: 8:1:4 8:1:4:1 Color 8 parts Color 8 parts Color Hardener 1 part LHF, LHM or LHS 1 part LHF, LHM or LHS Reducer 4 parts LR10, LR11, LR12, LR13 or LR15 (1) 4 parts LR10, LR11, LR12, LR13 or LR15 (1) Flex Agent — 1 part 892 Potlife at 68°F/20°C 4 hours 4 hours Spray viscosity Ford #4 @ 68°F/20°C 16 - 19 seconds 16 - 19 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm Spray pressure HVLP at the cap 10 psi 10 psi Application 2 - 3 coats (additional mist coat may be required for certain metallics) 2 - 3 coats (additional mist coat may be required for certain metallics) Flash-off time @ 68°F/20°C 5 - 10 minutes between coats 5 - 10 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 3.0 mils Coverage 246 sq. ft./gal @ 2.0 mils 246 sq. ft./gal @ 2.0 mils 68°F/20°C 45 - 60 minutes dust free; 6 hours to handle 45 - 60 minutes dust free; 6 hours to handle 140°F/60°C 35 minutes; allow 20 minutes flash before force dry 35 minutes; allow 20 minutes flash before force dry Infra red short wave 10 - 15 minutes 10 - 15 minutes Infra red medium wave 35 minutes 35 minutes Sanding: Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged Varies, dependent on color Varies, dependent on color VOC as applied 527 - 599 gms/liter (4.4 - 5.0 lbs/gal) 527 - 599 gms/liter (4.4 - 5.0 lbs/gal) Comments (1) LR15 is recommended for most high temperature conditions. LR15 will be used as a blend with LR13 (up to 50%). Drying: Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Limco Urethane (Limco 3) U.S. National Rule VOC Description: Limco Urethane is a specially formulated polyurethane with hardener which produces a superior high gloss and durable finish. Limco Urethane is also available in Quick Mix colors. Materials: Limco Bases: LB Bases Quick Mix Colors: Q Bases Urethane Mixing Clear: LMC3 Hardeners: LH310 LH320 Reducers: LR10 LR11 LR12 LR13 LR15 Flex Agent: 892 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 400 grit Primer Surfacer 800K 320 - 500 grit Primer Surfacer 846 320 - 500 grit Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LS56 Sanding not required Primer Sealer LS800 Sanding not required Primer Sealer PS21nr Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Limco Urethane (U.S. National Rule) colors, the color (LB, Q bases) must be mixed 2 parts to 1 part of LMC3 by volume prior to addition of hardener and reducer. US. Rev. 11/21/14 T E C H N I C A L D A T A Limco Urethane (Limco 3) U.S. National Rule VOC Flexed S Mixing ratio: 8:1:4 8:1:4:1 Color 8 parts Color 8 parts Color Hardener 1 part LH310 or LH320 1 part LH310 or LH320 Reducer 4 parts LR10, LR11, LR12, LR13 or LR15 (1) 4 parts LR10, LR11, LR12, LR13 or LR15 (1) Flex Agent — 1 part 892 Potlife at 68°F/20°C 4 hours 4 hours Spray viscosity Ford #4 @ 68°F/20°C 15 - 17 seconds 15 - 17 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm Spray pressure HVLP at the cap 8 - 10 psi 8 - 10 psi Application 2 - 3 coats (additional mist coat may be required for certain metallics) 2 - 3 coats (additional mist coat may be required for certain metallics) Flash-off time @ 68°F/20°C 5 - 10 minutes between coats 5 - 10 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 3.0 mils Coverage 270 - 290 sq. ft./gal @ 2.0 mils 270 - 290 sq. ft./gal @ 2.0 mils 68°F/20°C 45 - 60 minutes dust free; 4 hours to handle 45 - 60 minutes dust free; 4 hours to handle 140°F/60°C 35 minutes 35 minutes Infra red short wave 10 - 15 minutes 10 - 15 minutes Infra red medium wave 35 minutes 35 minutes Sanding: Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged Varies, dependent on color Varies, dependent on color VOC as applied 539 - 587 gms/liter (4.5 - 4.9 lbs/gal) 539 - 587 gms/liter (4.5 - 4.9 lbs/gal) Comments (1) LR15 is recommended for most high temperature conditions. LR15 will be used as a blend with LR13 (up to 50%). Drying: Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Limco Low VOC Urethane (Limco 3) 420 gms/liter (3.5 lbs/gal) VOC Description: Limco Low VOC Urethane 420 gms/liter (3.5 lbs/gal) VOC is a specially formulated polyurethane with hardener and accelerator which produces a superior high gloss durable finish. Limco Urethane 420 gms/liter (3.5 lbs/gal) VOC is also available in Quick Mix colors. Materials: Limco Bases: LB Bases Quick Mix Colors: Q Bases Flow Control: LB105 * Urethane Mixing Clear: LMC3HS Hardeners: LHF LHM LHS Reducers: LR21 LR25 Flex Agent: 892 Substrates prepared for topcoating: Finish Sanding Cleaner Well cured old paint work 400 grit R-M 909 Final Wipe Primer Surfacer H1000 320 - 400 grit (dry sand only) R-M 909 Final Wipe Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP610 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. * Limco Low VOC Urethane 420 gms/liter (3.5 lbs/gal) VOC Quick Mix colors must have LB105 Flow and Sag Control and LMC3HS Urethane Mixing Clear added prior to use. For custom Limco Low VOC Urethane (420 gms/liter) colors, the color (LB, Q bases) must be mixed 2 parts to 1 part of LMC3HS by volume prior to addition of hardener and reducer. LB105 Flow and Sag Control is contained in most color formulas, or may be added to Limco Low VOC Urethane 420 gms/liter (3.5 lbs/gal) VOC intermixes at a rate of 3% for solid colors or 5% for metallic colors prior to catalyzing the mixture. US. Rev. 11/21/14 T E C H N I C A L D A T A Limco Low VOC Urethane (Limco 3) 420 gms/liter (3.5 lbs/gal) VOC Flexed S Mixing ratio: 4:1:2 4:1:2:1 Color 4 parts Color 4 parts Color Hardener 1 part LHF, LHM or LHS 1 part LHF, LHM or LHS Reducer 2 parts LR21 or L25 2 parts LR21 or LR25 Flex Agent — 1 part 892 Potlife at 68°F/20°C 4 hours 4 hours Spray viscosity Ford #4 @ 68°F/20°C 14 - 16 seconds 14 - 16 seconds Gravity gun nozzle HVLP 1.5 - 1.7 mm 1.5 - 1.7 mm Spray pressure HVLP at the cap 10 psi 10 psi Application 2 coats (additional mist coat may be required for certain metallics) 2 coats (additional mist coat may be required for certain metallics) Flash-off time @ 68°F/20°C 5 - 10 minutes between coats 5 - 10 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 3.0 mils Coverage 320 sq. ft./gal @ 2.0 mils 320 sq. ft./gal @ 2.0 mils 68°F/20°C 2 to 3 hours dust free; 8 hours to handle 2 to 3 hours dust free; 8 hours to handle 140°F/60°C 30 minutes 30 minutes Infra red short wave 10 - 20 minutes 10 - 20 minutes Infra red medium wave 40 minutes 40 minutes Sanding: Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged Varies, dependent on color Varies, dependent on color VOC as applied 383 - 419 gms/liter (3.2 - 3.5 lbs/gal) 383 - 419 gms/liter (3.2 - 3.5 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Drying: Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Limco Basecoat (Limco 4) U.S. National Rule VOC Description: Limco Basecoat is part of a basecoat/clearcoat system that features high strength, fast hiding basecoat colors. This system can be used for the repair of original basecoat/clearcoat finishes or for a complete paint job. Limco Basecoat color must be clearcoated. Limco Basecoat is also available in Quick Mix colors. Materials: Limco Bases: LB Bases Quick Mix Colors: Q Bases Basecoat Mixing Clear: Reducers: LMC4 LBR1470 LBR1480 LBR1490 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 400 grit Primer Surfacer 800K 320 - 500 grit Primer Surfacer 846 320 - 500 grit Primer Surfacer LP20 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LS56 Sanding not required Primer Sealer LS800 Sanding not required Primer Sealer PS21nr Sanding not required Clearcoats: LC4000 LC4100 LC4500 Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Suggested temperature ranges for Limco Reducers LBR1470 LBR1480 LBR1490 US. Rev. 8/1/13 up to 75°F 75° - 90°F 90°F and up For custom Limco Basecoat (U.S. National Rule) colors, the color (LB, Q bases) must be mixed 2 parts to 1 part of LMC4 by volume prior to addition of reducer. T E C H N I C A L D A T A Limco Basecoat (Limco 4) U.S. National Rule VOC S Mixing ratio: 2:1 Color 2 parts Color Reducer 1 part LBR1470, LBR1480 or LBR1490 Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 12 - 14 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 coats or to hiding Flash-off time @ 68°F/20°C 5 - 10 minutes between coats; 5 minutes before force dry Film build 2.0 mils Coverage 470 sq. ft./gal @ 1.0 mil Drying: 68°F/20°C 20 minutes 140°F/60°C 10 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied 479 - 599 gms/liter (4.0 - 5.0 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Limco Basecoat (Limco 4) with hardener U.S. National Rule VOC Description: Limco Basecoat is part of a basecoat/clearcoat system that features high strength, fast hiding basecoat colors. This system can be used for the repair of original basecoat/clearcoat finishes or for a complete paint job. Limco Basecoat color must be clearcoated. The use of LHF Hardener will result in increased durability and intercoat adhesion, plus reduce any film softness that might be exhibited when using a poorer hiding color. Limco Basecoat is also available in Quick Mix colors. Materials: Limco Bases: LB Bases Quick Mix Colors: Q Bases Basecoat Mixing Clear: LMC4 Hardener LHF Reducers: LBR1470 LBR1480 LBR1490 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 400 grit Primer Surfacer 800K 320 - 500 grit Primer Surfacer 846 320 - 500 grit Primer Surfacer LP20 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LS56 Sanding not required Primer Sealer LS800 Sanding not required Primer Sealer PS21nr Sanding not required Clearcoats: LC4000 LC4100 LC4500 Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Suggested temperature ranges for Limco Reducers LBR1470 LBR1480 LBR1490 US. Rev. 8/1/13 up to 75°F 75° - 90°F 90°F and up For custom Limco Basecoat with hardener (U.S. National Rule) colors, the color (LB, Q bases) must be mixed 2 parts to 1 part of LMC4 by volume prior to addition of hardener and reducer. T E C H N I C A L D A T A Limco Basecoat (Limco 4) with hardener U.S. National Rule VOC S Mixing ratio: 8:1:4 Color 8 parts Color Hardener 1 part LHF Reducer 4 parts LBR1470, LBR1480 or LBR1490 Potlife at 68°F/20°C 2 hours Spray viscosity Ford #4 @ 68°F/20°C 12 - 14 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm Spray pressure HVLP at the cap 8 - 10 psi Application 2 - 3 coats or to hiding Flash-off time @ 68°F/20°C 5 - 10 minutes between coats; 5 minutes before force dry Film build 2.0 mils Coverage 518 sq. ft./gal @ 1.0 mil Drying: 68°F/20°C 20 minutes 140°F/60°C N/A Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied 575 - 653 gms/liter (4.8 - 5.4 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Limco Direct-to-metal Light Industrial Topcoat (Limco 5) U.S. National Rule VOC Description: Limco DTM topcoat is a two component, high build, acrylic urethane for topcoating properly prepared bare steel, aluminum and galvanized substrates. Limco DTM topcoat is a very glossy, durable and chemically resistant topcoat finish. It has excellent flow, leveling properties and good sag resistance. Materials: Limco Bases: LB Bases DTM Mixing Clear: LMC5 Hardeners: LHF LHM LHS LH710 * Reducers: LR10 LR11 LR12 LR13 LR15 Substrates prepared for topcoating: Finish Sanding Cleaner Steel 80 - 180 grit 203 Wax and Grease Remover Aluminum 120 - 180 grit 203 Wax and Grease Remover Zinc or Galvanized Coarse scuff pad 203 Wax and Grease Remover (Do not remove zinc or galvanized coating) Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Surface cleaning and preparation is critical for Limco DTM Topcoat's success. All grease, dirt and rust must be removed from substrate. * Use LH710 DTM Hardener for aluminum substrates. Agitate thoroughly on a mixing machine before each use. For custom Limco Direct-to-metal Light Industrial Topcoat (U.S. National Rule) colors, the color (LB bases) must be mixed 1 part to 1 part of LMC5 by volume prior to addition of hardener and reducer. US. Rev. 8/1/13 T E C H N I C A L D A T A Limco Direct-to-metal Light Industrial Topcoat (Limco 5) U.S. National Rule VOC S Mixing ratio: 4:1:1 Color 4 parts Color Hardener 1 part LHF, LHM, LHS or LH710 Reducer 1 part LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C 4 - 5 hours Spray viscosity Ford #4 @ 68°F/20°C 16 - 20 seconds Gravity gun nozzle HVLP 1.5 mm Spray pressure HVLP at the cap 9 - 10 psi Application 2 - 3 medium wet coats Flash-off time @ 68°F/20°C 5 minutes between coats Film build 2.0 - 3.0 mils Coverage 343 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 1.5 - 2 hours dust free 140°F/60°C 30 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied 455 - 491 gms/liter (3.8 - 4.1 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Limco Low VOC Industrial Urethane Single Stage (Limco 7) 420 gms/liter (3.5 lbs/gal) VOC Description: Limco Low VOC Industrial Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC is a specially formulated polyurethane with hardener and accelerator which produces a superior high gloss durable finish. Limco Low VOC Industrial Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC also available in Quick Mix colors. Materials: Limco Bases: LB Bases Quick Mix Colors: Q Bases CV Mixing Clear: LMC7 * Hardeners: LHF LHM LHS Reducers: LR21 LR25 Substrates prepared for topcoating: Finish Sanding Cleaner Well cured old paint work 400 grit R-M 909 Final Wipe Primer Surfacer H1000 320 - 400 grit (dry sand only) R-M 909 Final Wipe Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP610 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. * LMC7 available in 5 gallon container only. For custom Limco Low VOC Industrial Urethane Single Stage (420 gms/liter) colors, the color (LB, Q bases) must be mixed 2 parts to 1 part of LMC7 by volume prior to addition of hardener and reducer. US. Rev. 11/21/14 T E C H N I C A L D A T A Limco Low VOC Industrial Urethane Single Stage (Limco 7) 420 gms/liter (3.5 lbs/gal) VOC S Mixing ratio: 4:1:2 Color 4 parts Color Hardener 1 part LHF, LHM or LHS Reducer 2 parts LR21 or LR25 Potlife at 68°F/20°C 4 hours Spray viscosity Ford #4 @ 68°F/20°C 14 - 16 seconds Gravity gun nozzle HVLP 1.5 - 1.7 mm Spray pressure HVLP at the cap 10 psi Application 2 coats (additional mist coat may be required for some metallics) Flash-off time @ 68°F/20°C 5 to 10 minutes between coats Film build 2.0 - 3.0 mils Coverage 420 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 2 - 3 hours dust free, 8 hours to handle 140°F/60°C 30 minutes Infra red short wave 15 - 20 minutes Infra red medium wave 40 minutes Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied 383 - 419 gms/liter (3.2 - 3.5 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Acrylic 1K Single Stage U.S. National Rule VOC Description: Limco Supreme PLUS U.S. National Rule Topcoat is a specially formulated Acrylic 1K Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet markets. Limco Supreme PLUS U.S. National Rule Acrylic 1K Single Stage Topcoat dries quickly to a dust-free surface with excellent flow and leveling, good hiding and good gloss. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Acrylic 1K Mixing Clear: LA4999 Reducers: LR10 LR11 LR12 LR13 LR15 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer 800K 320 - 500 grit Primer Surfacer 846 320 - 500 grit Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP620 Sanding not required Primer Sealer LS56 Sanding not required Primer Sealer LS800 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Acrylic 1K (600 gms/liter) colors, the color (LA, LIB, G bases) must be mixed 1 part to 1 part of LA4999 by volume prior to addition of reducer. OPTIONAL: For a more durable finish, Limco Hardener LHF, LHM or LHS may be added at a ratio of 10:1 with 1 part of reducer. Caution: Lighter colors may yellow with the addition of hardener. Adding hardener will result in a four hour pot life. US Rev. 2/22/16 T E C H N I C A L D A T A Supreme PLUS Acrylic 1K Single Stage U.S. National Rule VOC S Mixing ratio: 8:1 Color 8 parts Color Reducer 1 part LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 14 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.7 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats Film build 2.0 - 3.0 mils Coverage 270 - 295 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 140°F/60°C 30 - 45 minutes dust free; 2 - 4 hours tack free 30 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied < 600 gms/liter (< 5.0 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. For areas requiring recoating four or more hours after application: Scuff with a fine scuff pad (Scotchbrite #7447). Cleaning:Use an air blow gun to remove all traces of dust and dirt from the cracks and surfaces of the vehicle. Clean all areas to be painted with 139 Final Wipe Cleaner. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Description: Limco Supreme PLUS Topcoat 340 gms/liter (2.8 lbs/gal) VOC is a specially formulated Acrylic 1K Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet markets. Limco Supreme PLUS Acrylic 1K Single Stage Topcoat 340 gms/liter (2.8 lbs/gal) VOC dries quickly to a dust-free surface with excellent flow and leveling, good hiding and good gloss. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Low VOC Acrylic 1K Mixing Clear: LA4899 Reducers: LR21 LR25 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer H1000 320 - 500 grit (dry sand only) Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP610 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP610 Sanding not required Primer Sealer LP620 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Low VOC Acrylic 1K (340 gms/liter) colors, the color (LA, LIB, G bases) must be mixed 1 part to 2.5 parts of LA4899 by volume prior to addition of reducer. OPTIONAL: For a more durable finish, Limco Low VOC Hardener LH401, LH405 or LH415 may be added at a ratio of 10:1 with 1 part of reducer. Caution: Lighter colors may yellow with the addition of hardener. Adding hardener will result in a four hour pot life. US Rev. 11/21/14 T E C H N I C A L D A T A Supreme PLUS Low VOC Acrylic 1K Single Stage 340 gms/liter (2.8 lbs/gal) VOC S Mixing ratio: 8:1 Color 8 parts Color Reducer 1 part LR21 or LR25 (may use up to 2 parts of reducer) Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 14 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.7 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats Film build 2.0 - 3.0 mils Coverage 262 - 285 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 140°F/60°C 60 - 90 minutes dust free; 3 - 5 hours tack free 30 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied < 340 gms/liter (< 2.8 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. For areas requiring recoating four or more hours after application: Scuff with a fine scuff pad (Scotchbrite #7447). Cleaning:Use an air blow gun to remove all traces of dust and dirt from the cracks and surfaces of the vehicle. Clean all areas to be painted with 909 Final Wipe Cleaner. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Description: Limco Supreme PLUS Topcoat 420 gms/liter (3.5 lbs/gal) VOC is a specially formulated Acrylic 1K Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet markets. Limco Supreme PLUS Acrylic 1K Single Stage Topcoat 420 gms/liter (3.5 lbs/gal) VOC dries quickly to a dust-free surface with excellent flow and leveling, good hiding and good gloss. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Low VOC Acrylic 1K Mixing Clear: LA4899 Reducers: LR10 LR11 LR12 LR13 LR15 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer H1000 320 - 500 grit (dry sand only) Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP610 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP610 Sanding not required Primer Sealer LP620 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Low VOC Acrylic 1K (420 gms/liter) colors, the color (LA, LIB, G bases) must be mixed 1 part to 2.5 parts of LA4899 by volume prior to addition of reducer. OPTIONAL: For a more durable finish, Limco Low VOC Hardener LH401, LH405 or LH415 may be added at a ratio of 10:1 with 1 part of reducer. Caution: Lighter colors may yellow with the addition of hardener. Adding hardener will result in a four hour pot life. US Rev. 11/21/14 T E C H N I C A L D A T A Supreme PLUS Low VOC Acrylic 1K Single Stage 420 gms/liter (3.5 lbs/gal) VOC S Mixing ratio: 8:1 Color 8 parts Color Reducer 1 part LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 14 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.7 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats Film build 2.0 - 3.0 mils Coverage 262 - 285 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 60 - 90 minutes dust free; 3 - 5 hours tack free 140°F/60°C 30 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied < 420 gms/liter (< 3.5 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. For areas requiring recoating four or more hours after application: Scuff with a fine scuff pad (Scotchbrite #7447). Cleaning:Use an air blow gun to remove all traces of dust and dirt from the cracks and surfaces of the vehicle. Clean all areas to be painted with 909 Final Wipe Cleaner. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Acrylic 2K Single Stage U.S. National Rule VOC Description: Limco Supreme PLUS U.S. National Rule Topcoat is a specially formulated Acrylic 2K Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet markets. Limco Supreme PLUS U.S. National Rule Acrylic 2K Single Stage Topcoat dries quickly to a dust-free surface with excellent flow and leveling, good hiding and mirror-like gloss. The Supreme PLUS U.S. National Rule Acrylic 2K Single Stage Topcoat film is also chemically resistant and has superior hardness. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Acrylic 2K Mixing Clear: LA3899 Hardeners: LHF LHM LHS Reducers: LR10 LR11 LR12 LR13 LR15 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer 800K 320 - 500 grit Primer Surfacer 846 320 - 500 grit Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP620 Sanding not required Primer Sealer LS56 Sanding not required Primer Sealer LS800 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Acrylic 2K (600 gms/liter) colors, the color (LA, LIB, G bases) must be mixed 1 part to 1 part of LA3899 by volume prior to addition of hardener and reducer. US Rev. 2/10/16 T E C H N I C A L D A T A Supreme PLUS Acrylic 2K Single Stage U.S. National Rule VOC S Mixing ratio: 8:1:1 Color 8 parts Color Hardener 1 part LHF, LHM or LHS Reducer 1 part LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C 2 - 4 hours Spray viscosity Ford #4 @ 68°F/20°C 14 - 16 seconds Gravity gun nozzle HVLP 1.3 - 1.7 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats Film build 2.0 - 3.0 mils Coverage 305 - 333 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 30 - 45 minutes dust free; 4 - 6 hours tack free 140°F/60°C 30 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied < 600 gms/liter (< 5.0 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC Description: Limco Supreme PLUS Topcoat 340 gms/liter (2.8 lbs/gal) VOC is a specially formulated Acrylic 2K Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet markets. Limco Supreme PLUS Acrylic 2K Single Stage Topcoat 340 gms/liter (2.8 lbs/gal) VOC dries quickly to a dust-free surface with excellent flow and leveling, good hiding and mirror-like gloss. The Supreme PLUS Acrylic 2K Single Stage Topcoat 340 gms/liter (2.8 lbs/gal) VOC film is also chemically resistant and has superior hardness. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Acrylic 2K Mixing Clear: LA3899 Hardeners: LH401 LH405 LH415 Reducers: LR21 LR25 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer H1000 320 - 500 grit (dry sand only) Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP610 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP610 Sanding not required Primer Sealer LP620 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Low VOC Acrylic 2K (340 gms/liter) colors, the color (LA, LIB, G bases) must be mixed 1 part to 2.5 parts of LA3899 by volume prior to addition of hardener and reducer. US Rev. 11/21/14 T E C H N I C A L D A T A Supreme PLUS Low VOC Acrylic 2K Single Stage 340 gms/liter (2.8 lbs/gal) VOC S Mixing ratio: 8:1:1 Color 8 parts Color Hardener 1 part LH401, LH405 or LH415 Reducer 1 part LR21 or LR25 (may use up to 2 parts of reducer) Potlife at 68°F/20°C 2 - 3 hours Spray viscosity Ford #4 @ 68°F/20°C 14 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.7 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats Film build 2.0 - 3.0 mils Coverage 278 - 300 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C LH401: 25 - 30 minutes dust free; 2 hours tack free (depending on reducer) LH405: 60 - 70 minutes dust free; 4 hours tack free (depending on reducer) 140°F/60°C 30 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied < 340 gms/liter (< 2.8 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC Description: Limco Supreme PLUS Topcoat 420 gms/liter (3.5 lbs/gal) VOC is a specially formulated Acrylic 2K Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet markets. Limco Supreme PLUS Acrylic 2K Single Stage Topcoat 420 gms/liter (3.5 lbs/gal) VOC dries quickly to a dust-free surface with excellent flow and leveling, good hiding and mirror-like gloss. The Supreme PLUS Acrylic 2K Single Stage Topcoat 420 gms/liter (3.5 lbs/gal) VOC film is also chemically resistant and has superior hardness. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Acrylic 2K Mixing Clear: LA3899 Hardeners: LH401 LH405 LH415 Reducers: LR10 LR11 LR12 LR13 LR15 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer H1000 320 - 500 grit (dry sand only) Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP610 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP610 Sanding not required Primer Sealer LP620 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Low VOC Acrylic 2K (420 gms/liter) colors, the color (LA, LIB, G bases) must be mixed 1 part to 2.5 parts of LA3899 by volume prior to addition of hardener and reducer. US Rev. 11/21/14 T E C H N I C A L D A T A Supreme PLUS Low VOC Acrylic 2K Single Stage 420 gms/liter (3.5 lbs/gal) VOC S Mixing ratio: 8:1:1 Color 8 parts Color Hardener 1 part LH401, LH405 or LH415 Reducer 1 part LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C 2 - 3 hours Spray viscosity Ford #4 @ 68°F/20°C 14 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.7 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats Film build 2.0 - 3.0 mils Coverage 278 - 300 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 35 - 45 minutes dust free: 4 - 6 hours tack free 140°F/60°C 30 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied < 420 gms/liter (< 3.5 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Urethane Single Stage U.S. National Rule VOC with LA2799 Description: Limco Supreme PLUS U.S. National Rule Topcoat is a specially formulated 2K Urethane Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet markets. Limco Supreme PLUS U.S. National Rule Urethane Single Stage Topcoat dries quickly to a dust-free surface with excellent flow and leveling, good hiding and mirror-like gloss. The Supreme PLUS U.S. National Rule Urethane Single Stage Topcoat film is also chemically resistant and has superior hardness. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Urethane Mixing Clear: LA2799 Hardeners: LHF LHM LHS Reducers: LR10 LR11 LR12 LR13 LR15 Flex Agent: 892 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer 800K 320 - 500 grit Primer Surfacer 846 320 - 500 grit Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP620 Sanding not required Primer Sealer LS56 Sanding not required Primer Sealer LS800 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Urethane Single Stage (U.S. National Rule) colors, the color (LA, LIB, G bases) must be mixed 2 parts to 1 part of LA2799 by volume prior to addition of hardener and reducer. US Rev. 2/22/16 T E C H N I C A L D A T A Supreme PLUS Urethane Single Stage U.S. National Rule VOC with LA2799 Flexed S Mixing ratio: 4:1:2 8:3:2:2 Color 4 parts Color 8 parts Color Hardener 1 part LHF, LHM or LHS 3 part LHF, LHM or LHS Flex Agent — 2 part 892 Reducer 2 parts LR10, LR11, LR12, LR13 or LR15 2 part LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C 4 hours 4 hours Spray viscosity Ford #4 @ 68°F/20°C 16 - 18 seconds 16 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi Application 2 - 3 wet coats 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 3.0 mils Coverage 575 - 625 sq. ft./gal @ 1.0 mil 700 - 750 sq. ft./gal @ 1.0 mil 68°F/20°C 3 - 4 hours dust free; 8 - 10 hours to handle 3 - 4 hours dust free; 8 - 10 hours to handle 140°F/60°C 30 minutes 30 minutes Infra red short wave N/A N/A Infra red medium wave N/A N/A Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged Varies, dependent on color Varies, dependent on color VOC as applied < 600 gms/liter (< 5.0 lbs/gal) < 600 gms/liter (< 5.0 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Drying: Sanding: Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Urethane Single Stage U.S. National Rule VOC with LA2999 Description: Limco Supreme PLUS U.S. National Rule Topcoat is a specially formulated 2K Urethane Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet markets. Limco Supreme PLUS U.S. National Rule Urethane Single Stage Topcoat dries quickly to a dust-free surface with excellent flow and leveling, good hiding and mirror-like gloss. The Supreme PLUS U.S. National Rule Urethane Single Stage Topcoat film is also chemically resistant and has superior hardness. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Urethane Single Stage Mixing Clear: LA2999 LA2999S (Slow) Hardeners: LHF LHM LHS Reducers: LR10 LR11 LR12 LR13 LR15 Flex Agent: 892 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer 800K 320 - 500 grit Primer Surfacer 846 320 - 500 grit Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP620 Sanding not required Primer Sealer LS56 Sanding not required Primer Sealer LS800 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Urethane Single Stage (U.S. National Rule) colors, the color (LA, LIB, G bases) must be mixed 1 part to 1 part of LA2999 by volume prior to addition of hardener and reducer. For larger areas, use LA2999S for slower application properties. US Rev. 8/4/15 T E C H N I C A L D A T A Supreme PLUS Urethane Single Stage U.S. National Rule VOC with LA2999 Flexed S Mixing ratio: 4:1:2 4:1:1:1 Color 4 parts Color 4 parts Color Hardener 1 part LHF, LHM or LHS 1 part LHF, LHM or LHS Flex Agent — 1 part 892 Reducer 2 parts LR10, LR11, LR12, LR13 or LR15 1 part LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C 1 - 1.5 hours 3 - 4 hours with LA2999S 1 - 1.5 hours 3 - 4 hours with LA2999S Spray viscosity Ford #4 @ 68°F/20°C 16 - 18 seconds 16 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi Application 2 - 3 wet coats 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 3.0 mils Coverage 575 - 625 sq. ft./gal @ 1.0 mil 700 - 750 sq. ft./gal @ 1.0 mil 68°F/20°C 1 - 1.5 hours with LA2999S:3 - 4 hours dust free; 8 hours to handle 1 - 1.5 hours with LA2999S:3 - 4 hours dust free; 8 hours to handle 140°F/60°C 30 minutes 30 minutes Infra red short wave N/A N/A Infra red medium wave N/A N/A Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged Varies, dependent on color Varies, dependent on color VOC as applied < 600 gms/liter (< 5.0 lbs/gal) < 600 gms/liter (< 5.0 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Drying: Sanding: Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC with LA2799 Description: Limco Supreme PLUS Topcoat 340 gms/liter (2.8 lbs/gal) VOC is a specially formulated 2K Urethane Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet markets. Limco Supreme PLUS Urethane Single Stage Topcoat 340 gms/liter (2.8 lbs/gal) VOC dries quickly to a dust-free surface with excellent flow and leveling, good hiding and mirror-like gloss. The Supreme PLUS Urethane Single Stage Topcoat 340 gms/liter (2.8 lbs/gal) VOC film is also chemically resistant and has superior hardness. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Urethane Mixing Clear: LA2799 Hardeners: LH601 LH604 LH606 Reducers: LR21 LR25 Flex Agent: 892 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer H1000 320 - 500 grit (dry sand only) Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP610 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP610 Sanding not required Primer Sealer LP620 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Low VOC Urethane Single Stage (340 gms/liter) colors, the color (LA, LIB, G bases) must be mixed 1 part to 1 part of LA2799 by volume prior to addition of hardener and reducer. US Rev. 2/24/16 T E C H N I C A L D A T A Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC with LA2799 Flexed S Mixing ratio: 4:1:2 8:3:2:2 Color 4 parts Color 8 parts Color Hardener 1 part LH601, LH604 or LH606 3 parts LH601, LH604 or LH606 Flex Agent — 2 parts 892 Reducer 2 parts LR21 or LR25 2 parts LR21 or LR25 Potlife at 68°F/20°C 4 hours 4 hours Spray viscosity Ford #4 @ 68°F/20°C 16 - 18 seconds 16 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi Application 2 - 3 wet coats 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 3.0 mils Coverage 600 - 650 sq. ft./gal @ 1.0 mil 690 - 730 sq. ft./gal @ 1.0 mil 68°F/20°C 3 - 4 hours dust free; 8 - 10 hours to handle 3 - 4 hours dust free; 8 - 10 hours to handle 140°F/60°C 30 minutes 30 minutes Infra red short wave N/A N/A Infra red medium wave N/A N/A Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged Varies, dependent on color Varies, dependent on color VOC as applied < 340 gms/liter (< 2.8 lbs/gal) < 340 gms/liter (< 2.8 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Drying: Sanding: Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC with LA2899 Description: Materials: Limco Supreme PLUS Topcoat 340 gms/liter (2.8 lbs/gal) VOC is a specially formulated 2K Urethane Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet markets. Limco Supreme PLUS Urethane Single Stage Topcoat 340 gms/liter (2.8 lbs/gal) VOC dries quickly to a dust-free surface with excellent flow and leveling, good hiding and mirror-like gloss. The Supreme PLUS Urethane Single Stage Topcoat 340 gms/liter (2.8 lbs/gal) VOC film is also chemically resistant and has superior hardness. Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Low VOC Urethane Single Stage Mixing Clear: LA2899 Hardeners: LH401 LH405 LH415 Reducers: LR21 LR25 Flex Agent: 892 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer H1000 320 - 500 grit (dry sand only) Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP610 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP610 Sanding not required Primer Sealer LP620 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Low VOC Urethane Single Stage (340 gms/liter) colors, the color (LA, LIB, G bases) must be mixed 1 part to 2 parts of LA2899 by volume prior to addition of hardener and reducer. US Rev. 8/4/15 T E C H N I C A L D A T A Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC with LA2899 Flexed S Mixing ratio: 8:2:2 8:3:2:2 Color 8 parts Color 8 parts Color Hardener 2 parts LH401, LH405 or LH415 3 parts LH401, LH405 or LH415 Flex Agent — 2 parts 892 Reducer 2 parts LR21 or LR25 2 parts LR21 or LR25 Potlife at 68°F/20°C 1 - 1.5 hours 1 - 1.5 hours Spray viscosity Ford #4 @ 68°F/20°C 16 - 18 seconds 16 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi Application 2 - 3 wet coats 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 3.0 mils Coverage 600 - 650 sq. ft./gal @ 1.0 mil 690 - 730 sq. ft./gal @ 1.0 mil 68°F/20°C 1 hour 1 hour 140°F/60°C 30 minutes 30 minutes Infra red short wave N/A N/A Infra red medium wave N/A N/A Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged Varies, dependent on color Varies, dependent on color VOC as applied < 340 gms/liter (< 2.8 lbs/gal) < 340 gms/liter (< 2.8 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Drying: Sanding: Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC with LA2799 Description: Limco Supreme PLUS Topcoat 420 gms/liter (3.5 lbs/gal) VOC is a specially formulated 2K Urethane Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet markets. Limco Supreme PLUS Urethane Single Stage Topcoat 420 gms/liter (3.5 lbs/gal) VOC dries quickly to a dust-free surface with excellent flow and leveling, good hiding and mirror-like gloss. The Supreme PLUS Urethane Single Stage Topcoat 420 gms/liter (3.5 lbs/gal) VOC film is also chemically resistant and has superior hardness. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Urethane Mixing Clear: LA2799 Hardeners: LH401 LH405 LH415 Reducers: LR21 LR25 Flex Agent: 892 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer H1000 320 - 500 grit (dry sand only) Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP610 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP610 Sanding not required Primer Sealer LP620 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Low VOC Urethane Single Stage (420 gms/liter) colors, the color (LA, LIB, G bases) must be mixed 2 parts to 1 part of LA2799 by volume prior to addition of hardener and reducer. US Rev. 2/22/16 T E C H N I C A L D A T A Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC with LA2799 Flexed S Mixing ratio: 4:1:2 8:3:2:2 Color 4 parts Color 8 parts Color Hardener 1 part LH401, LH405 or LH415 3 parts LH401, LH405 or LH415 Flex Agent — 2 parts 892 Reducer 2 parts LR21 or LR25 2 parts LR21 or LR25 Potlife at 68°F/20°C 1 - 1.5 hours 1 - 1.5 hours Spray viscosity Ford #4 @ 68°F/20°C 16 - 18 seconds 16 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi Application 2 - 3 wet coats 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 3.0 mils Coverage 600 - 650 sq. ft./gal @ 1.0 mil 690 - 730 sq. ft./gal @ 1.0 mil 68°F/20°C 3 - 4 hours dust free; 8 - 10 hours to handle 3 - 4 hours dust free; 8 - 10 hours to handle 140°F/60°C 30 minutes 30 minutes Infra red short wave N/A N/A Infra red medium wave N/A N/A Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged Varies, dependent on color Varies, dependent on color VOC as applied < 420 gms/liter (< 3.5 lbs/gal) < 420 gms/liter (< 3.5 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Drying: Sanding: Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC with LA2899 Description: Materials: Limco Supreme PLUS Topcoat 420 gms/liter (3.5 lbs/gal) VOC is a specially formulated 2K Urethane Single Stage system designed to meet the rigorous demands of Refinish, Commercial Vehicle, Agricultural and Fleet markets. Limco Supreme PLUS Urethane Single Stage Topcoat 420 gms/liter (3.5 lbs/gal) VOC dries quickly to a dust-free surface with excellent flow and leveling, good hiding and mirror-like gloss. The Supreme PLUS Urethane Single Stage Topcoat 420 gms/liter (3.5 lbs/gal) VOC film is also chemically resistant and has superior hardness. Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Low VOC Urethane Single Stage Mixing Clear: LA2899 Hardeners: LH401 LH405 LH415 Reducers: LR10 LR11 LR12 LR13 LR15 Flex Agent: 892 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer H1000 320 - 500 grit (dry sand only) Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP610 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP610 Sanding not required Primer Sealer LP620 Sanding not required Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Low VOC Urethane Single Stage (420 gms/liter) colors, the color (LA, LIB, G bases) must be mixed 1 part to 2 parts of LA2899 by volume prior to addition of hardener and reducer. US Rev. 8/4/15 T E C H N I C A L D A T A Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC with LA2899 Flexed S Mixing ratio: 8:2:1 8:3:2:2 Color 8 parts Color 8 parts Color Hardener 2 parts LH401, LH405 or LH415 3 parts LH401, LH405 or LH415 Flex Agent — 2 parts 892 Reducer 1 part LR10, LR11, LR12, LR13 or LR15 2 parts LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C 1 - 1.5 hours 1 - 1.5 hours Spray viscosity Ford #4 @ 68°F/20°C 16 - 18 seconds 16 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi 6 - 10 psi Application 2 - 3 wet coats 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 3.0 mils Coverage 600 - 650 sq. ft./gal @ 1.0 mil 690 - 730 sq. ft./gal @ 1.0 mil 68°F/20°C 1 hour 1 hour 140°F/60°C 30 minutes 30 minutes Infra red short wave N/A N/A Infra red medium wave N/A N/A Wet by Hand N/A N/A Dry by Hand N/A N/A Dry by Machine N/A N/A VOC as packaged Varies, dependent on color Varies, dependent on color VOC as applied < 420 gms/liter (< 3.5 lbs/gal) < 420 gms/liter (< 3.5 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Drying: Sanding: Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Basecoat U.S. National Rule VOC Description: Limco Supreme PLUS U.S. National Rule Basecoat is a Basecoat/Clearcoat system that features high strength, fast hiding basecoat colors and a very durable clearcoat. This system can be used for the repair of original basecoat/clearcoat finishes or for a complete paint job. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Basecoat Mixing Clear: LA1399 Reducers: LR10 LR11 LR12 LR13 LR15 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer 800K 320 - 500 grit Primer Surfacer 846 320 - 500 grit Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP620 Sanding not required Primer Sealer LS56 Sanding not required Primer Sealer LS800 Sanding not required Clearcoats: LC4100 LC4500 Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Basecoat (U.S. National Rule) colors, the color (LA, LIB, G bases) must be mixed 2 parts to 1 part of LA1399 by volume prior to addition of reducer. US Rev. 11/21/14 T E C H N I C A L D A T A Supreme PLUS Basecoat U.S. National Rule VOC S Mixing ratio: 2:1 Color 2 parts Color Reducer 1 part LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 14 - 16 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 - 10 minutes between coats Film build 0.5 - 1.5 mils Coverage 275 - 410 sq. ft./gal @ 1.0 mil Drying: 68°F/20°C 15 - 30 minutes before clearcoating 140°F/60°C 10 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied < 680 gms/liter (< 5.7 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC Description: Limco Supreme PLUS Low VOC Basecoat is a Basecoat/Clearcoat system that features high strength, fast hiding basecoat colors and a very durable clearcoat. This system can be used for the repair of original basecoat/clearcoat finishes or for a complete paint job. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases Low VOC Basecoat Mixing Clear: LA1299 Hardeners: LH401 LH405 LH415 Reducers: LR21 LR25 Substrates prepared for topcoating: Finish Sanding Well cured old paint work 500 grit Primer Surfacer H1000 320 - 500 grit (dry sand only) Primer Surfacer LP20 320 - 500 grit Primer Surfacer LP610 320 - 500 grit Primer Surfacer LP620 320 - 500 grit Primer Sealer LP20 Sanding not required Primer Sealer LP610 Sanding not required Primer Sealer LP620 Sanding not required Clearcoats: LC4200 LC4800 Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For custom Supreme PLUS Low VOC Basecoat (420 gms/liter) colors, the color (LA, LIB, G bases) must be mixed 1 part to 2 parts of LA1299 by volume prior to addition of hardener and reducer. US Rev. 11/21/14 T E C H N I C A L D A T A Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC S Mixing ratio: 3:1 + 3% Color 3 parts Color Reducer 1 - 2 parts LR21 or LR25 Hardener 3% LH401, LH405 or LH415 Potlife at 68°F/20°C N/A Spray viscosity Ford #4 @ 68°F/20°C 14 - 16 seconds Gravity gun nozzle HVLP 1.3 - 1.5 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 - 10 minutes between coats Film build 0.8 - 1.2 mils Coverage 275 - 430 sq. ft./gal @ 1.0 mil Drying: 68°F/20°C 15 - 30 minutes before clearcoating 140°F/60°C 10 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied < 420 gms/liter (< 3.5 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS 2K Direct-to-metal U.S. National Rule VOC Description: Limco Supreme PLUS U.S. National Rule 2K Direct-to-metal Topcoat is a two component, high build, acrylic urethane for topcoating properly prepared bare steel, aluminum and galvanized substrates. Limco Supreme PLUS 2K Direct-to-metal topcoat is a very glossy, durable and chemically resistant topcoat finish. It has excellent flow, leveling properties and good sag resistance. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases DTM Mixing Clear: LA5999 Hardener: LH710 Reducers: LR10 LR11 LR12 LR13 LR15 Substrates prepared for topcoating: Cleaning Finish Sanding Steel 203 Wax and Grease Remover 80 - 180 grit 139 Final Wash Cleaner Aluminum 203 Wax and Grease Remover 120 - 180 grit 139 Final Wash Cleaner Zinc or Galvanized 203 Wax and Grease Remover Coarse scuff pad 139 Final Wash Cleaner Second Cleaning NOTES: Make sure sanding is not so vigorous that it removes the galvanized or zinc coating. With the second cleaning, make sure all residue is removed. Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Surface cleaning and preparation is critical for Limco Supreme PLUS 2K Direct-to-metal Topcoat's success. All grease, dirt and rust must be removed from substrate. Agitate thoroughly on a mixing machine before each use. For custom Supreme PLUS 2K Direct-to-metal (U.S. National Rule) colors, the color (LA, LIB, G bases) must be mixed 1 part to 2 parts of LA5999 by volume prior to addition of hardener and reducer. US. Rev. 11/21/14 T E C H N I C A L D A T A Supreme PLUS 2K Direct-to-metal U.S. National Rule VOC S Mixing ratio: 4:1:1 Color 4 parts Color Hardener 1 part LH710 Reducer 1 part LR10, LR11, LR12, LR13 or LR15 Potlife at 68°F/20°C 4 hours Spray viscosity Ford #4 @ 68°F/20°C 14 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.7 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats Film build 2.0 - 3.0 mils Coverage 275 - 295 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 25 - 30 minutes dust free; 2 hours tack free (depending on reducer) 140°F/60°C 30 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied < 600 gms/liter (< 5.0 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. T O P C O AT S Supreme PLUS 2K Direct-to-metal 420 gms/liter (3.5 lbs/gal) VOC Description: Limco Supreme PLUS 2K Direct-to-metal Topcoat 420 gms/liter (3.5 lbs/gal) VOC is a two component, high build, acrylic urethane for topcoating properly prepared bare steel, aluminum and galvanized substrates. Limco Supreme PLUS 2K Direct-to-metal Topcoat 420 gms/liter (3.5 lbs/gal) VOC is a very glossy, durable and chemically resistant topcoat finish. It has excellent flow, leveling properties and good sag resistance. Materials: Supreme Bases: LA & LIB Bases Supreme Grab & Go Colors: G Bases DTM Mixing Clear: LA5999 Hardener: LH710 Reducers: LR21 LR25 Substrates prepared for topcoating: Cleaning Finish Sanding Second Cleaning Steel R-M 909 Final Wipe 80 - 180 grit R-M 909 Final Wipe Aluminum R-M 909 Final Wipe 120 - 180 grit R-M 909 Final Wipe Zinc or Galvanized R-M 909 Final Wipe Coarse scuff pad R-M 909 Final Wipe NOTES: Make sure sanding is not so vigorous that it removes the galvanized or zinc coating. With the second cleaning, make sure all residue is removed. Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Surface cleaning and preparation is critical for Limco Supreme PLUS 2K Direct-to-metal Topcoat's success. All grease, dirt and rust must be removed from substrate. Agitate thoroughly on a mixing machine before each use. For custom Supreme PLUS 2K Direct-to-metal (420 gms/liter) colors, the color (LA, LIB, G bases) must be mixed 1 part to 2 parts of LA5999 by volume prior to addition of hardener and reducer. US. Rev. 11/21/14 T E C H N I C A L D A T A Supreme PLUS 2K Direct-to-metal 420 gms/liter (3.5 lbs/gal) VOC S Mixing ratio: 4:1:1 Color 4 parts Color Hardener 1 part LH710 Reducer 1 part LR21 or LR25 Potlife at 68°F/20°C 4 hours Spray viscosity Ford #4 @ 68°F/20°C 14 - 18 seconds Gravity gun nozzle HVLP 1.3 - 1.7 mm Spray pressure HVLP at the cap 6 - 10 psi Application 2 - 3 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats Film build 2.0 - 3.0 mils Coverage 275 - 295 sq. ft./gal @ 2.0 mils Drying: 68°F/20°C 25 - 30 minutes dust free; 2 hours tack free (depending on reducer) 140°F/60°C 30 minutes Infra red short wave N/A Infra red medium wave N/A Sanding: Wet by Hand N/A Dry by Hand N/A Dry by Machine N/A VOC as packaged Varies, dependent on color VOC as applied < 420 gms/liter (< 3.5 lbs/gal) Comments Shake new tinting bases for 15 minutes using a mechanical paint shaker before placing on a mixing machine. Tinting bases on a mixing machine need to be agitated for 15 minutes at the start of the work day and every 4 hours during the day to ensure good color matching. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. C L E A R C O AT S LC4000 Clearcoat U.S. National Rule VOC Description: Limco LC4000 Clearcoat is an acrylic urethane clear for use over Limco Basecoat (Limco 4) colors. It is designed to increase the profitability and productivity of the repair facility. It is U.S. National Rule compliant, easy to apply and has excellent gloss and leveling. Materials: Clearcoat: LC4000 Hardeners: LHF LHM LHS Flex Agent: 892 Basecoat: Limco Basecoat (Limco 4) Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. LC4000 is not covered by a warranty and should not be used with warrantable systems. US Rev. 8/1/13 T E C H N I C A L D A T A LC4000 Clearcoat U.S. National Rule VOC Flexed S Mixing ratio: 4:1 4:2:1 Clear 4 parts LC4000 4 parts LC4000 Hardener 1 part LHF, LHM or LHS 2 parts LHF, LHM or LHS Flex Agent — 1 part 892 Potlife at 68°F/20°C 6 hours 4 hours Spray viscosity Ford #4 @ 68°F/20°C 14 - 16 seconds 15 - 17 seconds Gravity gun nozzle HVLP 1.1 - 1.3 mm 1.1 - 1.3 mm Spray pressure HVLP at the cap 9 - 10 psi 9 - 10 psi Application 2 - 3 coats 2 - 3 coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 - 2.4 mils 2.0 - 2.4 mils Coverage 506 sq. ft./gal @ 1.0 mil 693 sq. ft./gal @ 1.0 mil 68°F/20°C 30 minutes dust free; 8 hours to handle 30 minutes dust free; 8 hours to handle 140°F/60°C 30 minutes; must allow 5 minutes flash before force dry 30 minutes; must allow 5 minutes flash before force dry Infra red short wave 6 - 8 minutes 6 - 8 minutes Infra red medium wave N/A N/A Wet by Hand 1200 or Finer 1200 or Finer Dry by Hand 1200 or Finer 1200 or Finer Dry by Machine 1200 or Finer 1200 or Finer VOC as packaged 633 gms/liter (5.3 lbs/gal) 633 gms/liter (5.3 lbs/gal) VOC as applied 550 gms/liter (4.6 lbs/gal) 484 gms/liter (4.1 lbs/gal) Comments Wait 24 hours before sanding, compounding or recoating. Drying: Sanding: Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. C L E A R C O AT S LC4100 High Solids Clearcoat U.S. National Rule VOC Description: Limco LC4100 High Solids Clearcoat is a U.S. National Rule Compliant acrylic urethane clear for use over Limco Basecoat (Limco 4) and Supreme PLUS Basecoat colors. It is designed to increase the profitability and productivity of the repair facility. LC4100 is an easy to apply two coat clear that has excellent gloss and leveling. LC4100 offers a range of reducers to meet your temperature needs. Materials: Clearcoat: LC4100 Hardeners: LHF LHM LHS Reducers: LR10 LR11 LR12 LR13 LR15 LR21 LR25 Flex Agent: 892 Basecoats: Limco Basecoat (Limco 4) Supreme PLUS Basecoat Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. LC4100 is not covered by a warranty and should not be used with warrantable systems. US Rev. 11/21/14 T E C H N I C A L D A T A LC4100 High Solids Clearcoat U.S. National Rule VOC Flexed * S Mixing ratio: 8:2:1 4:1:1 4:2:1:1 Clear 8 parts LC4100 4 parts LC4100 4 parts LC4100 Hardener 2 part LHF, LHM or LHS 1 part LHF, LHM or LHS 2 parts LHF, LHM or LHS Reducer 1 part LR10, LR11, LR12, LR13 or LR15 1 part LR21 or LR25 1 part LR10, LR11, LR12, LR13 or LR15 Flex Agent — — 1 part 892 Potlife at 68°F/20°C 4 hours 5 hours 3 hours Spray viscosity Ford #4 @ 68°F/20°C 14 - 16 seconds 14 - 16 seconds 15 - 17 seconds Gravity gun nozzle HVLP 1.1 - 1.3 mm 1.1 - 1.3 mm 1.1 - 1.3 mm Spray pressure HVLP at the cap 9 - 10 psi 9 - 10 psi 9 - 10 psi Application 2 coats 2 coats 2 coats Flash-off time @ 68°F/20°C 5 - 10 minutes between coats 5 - 10 minutes between coats 5 - 10 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 2.4 mils 2.0 - 3.0 mils Coverage 617 sq. ft./gal @ 1.0 mil 565 sq. ft./gal @ 1.0 mil 677 sq. ft./gal @ 1.0 mil 68°F/20°C 30 minutes dust free; 8 hours to handle 30 minutes dust free; 8 hours to handle 45 minutes dust free; 8 hours to handle 140°F/60°C 30 minutes; must allow 5 minutes flash before force dry 30 minutes; must allow 5 minutes flash before force dry 30 minutes; must allow 5 minutes flash before force dry Infra red short wave 6 - 10 minutes 6 - 10 minutes 6 - 10 minutes Infra red medium wave N/A N/A N/A Wet by Hand 1200 or Finer 1200 or Finer 1200 or Finer Dry by Hand 1200 or Finer 1200 or Finer 1200 or Finer Dry by Machine 1200 or Finer 1200 or Finer 1200 or Finer VOC as packaged 552 gms/liter (4.6 lbs/gal) 552 gms/liter (4.6 lbs/gal) 552 gms/liter (4.6 lbs/gal) VOC as applied 535 gms/liter (4.5 lbs/gal) 500 gms/liter (4.2 lbs/gal) 497 gms/liter (4.2 lbs/gal) Comments Wait 24 hours before sanding, compounding or recoating. Drying: Sanding: * Mixing with flex agent will alter dry times and viscosity. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. C L E A R C O AT S LC4200 Low VOC Clearcoat 250 gms/liter (2.1 lbs/gal) VOC Description: Limco LC4200 Clearcoat is a low 250 gms/liter (2.1 lbs/gal) VOC acrylic urethane clearcoat for use over Supreme PLUS Low VOC Basecoat colors. LC4200 is easy to apply and has excellent gloss and leveling. Materials: Clearcoat: LC4200 Hardeners: LH401 LH405 LH415 Flex Agent: 892 Basecoat: Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. LC4200 is not covered by a warranty and should not be used with warrantable systems. US Rev. 11/21/14 T E C H N I C A L D A T A LC4200 Clearcoat 250 gms/liter (2.1 lbs/gal) VOC Flexed S Mixing ratio: 4:1 8:2:1 Clear 4 parts LC4200 8 parts LC4200 Hardener 1 part LH401, LH405 or LH415 2 parts LH401, LH405 or LH415 Flex Agent — 1 part 892 Potlife at 68°F/20°C 1.5 hours 1.5 hours Spray viscosity Ford #4 @ 68°F/20°C 15 - 17 seconds 15 - 17 seconds Gravity gun nozzle HVLP 1.1 - 1.3 mm 1.1 - 1.3 mm Spray pressure HVLP at the cap 9 - 10 psi 9 - 10 psi Application 2 - 3 coats 2 - 3 coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 - 2.4 mils 2.0 - 2.4 mils Coverage 640 sq. ft./gal @ 1.0 mil 670 sq. ft./gal @ 1.0 mil 68°F/20°C 45 minutes dust free; 8 hours to handle 45 minutes dust free; 8 hours to handle 140°F/60°C 30 minutes; must allow 5 minutes flash before force dry 30 minutes; must allow 5 minutes flash before force dry Infra red short wave 6 - 10 minutes 6 - 10 minutes Infra red medium wave N/A N/A Wet by Hand 1200 or Finer 1200 or Finer Dry by Hand 1200 or Finer 1200 or Finer Dry by Machine 1200 or Finer 1200 or Finer VOC as packaged 204 gms/liter (1.7 lbs/gal) 204 gms/liter (1.7 lbs/gal) VOC as applied 239 gms/liter (2.0 lbs/gal) 225 gms/liter (1.9 lbs/gal) Comments Wait 24 hours before sanding, compounding or recoating. Drying: Sanding: Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. C L E A R C O AT S LC4500 Express Clear U.S. National Rule VOC Description: Limco LC4500 Express Clear is a U.S. National Rule Compliant acrylic urethane clear for use over Limco Basecoat (Limco 4) and Supreme PLUS Basecoat colors. It is designed to increase the profitability and productivity of the repair facility. LC4500 is an easy to apply two coat clear that has excellent gloss and leveling. LC4500 offers a range of reducers to meet your temperature needs. Materials: Clearcoat: LC4500 Hardeners: LHF LHM LHS Reducers: LR10 LR11 LR12 LR13 LR15 Flex Agent: 892 Basecoats: Limco Basecoat (Limco 4) Supreme PLUS Basecoat Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. LC4500 is not covered by a warranty and should not be used with warrantable systems US Rev. 11/21/14 T E C H N I C A L D A T A LC4500 Express Clear U.S. National Rule VOC Flexed S Mixing ratio: 8:2:1 4:2:1:1 Clear 8 parts LC4500 4 parts LC4500 Hardener 2 parts LHF, LHM or LHS 2 parts LHF, LHM or LHS Reducer 1 part LR10, LR11, LR12, LR13 or LR15 1 part LR10, LR11, LR12, LR13 or LR15 Flex Agent — 1 part 892 Potlife at 68°F/20°C 2 - 3 hours 2 hours Spray viscosity Ford #4 @ 68°F/20°C 13 - 15 seconds 12 - 14 seconds Gravity gun nozzle HVLP 1.1 - 1.3 mm 1.1 - 1.3 mm Spray pressure HVLP at the cap 9 - 10 psi 9 - 10 psi Application 2 - 3 coats 2 - 3 coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 - 3.0 mils 2.0 - 3.0 mils Coverage 572 sq. ft./gal @ 1.0 mil 649 sq. ft./gal @ 1.0 mil 68°F/20°C 15 minutes dust free; 3 - 4 hours to handle 15 minutes dust free; 3 - 4 hours to handle 140°F/60°C 30 minutes; may be handled or polished after cool down 30 minutes; may be handled or polished after cool down Infra red short wave 6 - 10 minutes 6 - 10 minutes Infra red medium wave N/A N/A Wet by Hand 1200 or Finer 1200 or Finer Dry by Hand 1200 or Finer 1200 or Finer Dry by Machine 1200 or Finer 1200 or Finer VOC as packaged 539 gms/liter (4.5 lbs/gal) 539 gms/liter (4.5 lbs/gal) VOC as applied 535 gms/liter (4.4 lbs/gal) 486 gms/liter (4.1 lbs/gal) Comments Wait 8 hours before sanding, compounding or recoating. Drying: Sanding: Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. C L E A R C O AT S LC4800 Low 2.0 VOC Express Clear 250 gms/liter (2.1 lbs/gal) VOC Description: Limco LC4800 Low 2.0 VOC Express Clear is a two component, 250 gms/liter (2.1 lbs/gal) VOC compliant fast acrylic urethane clear for use over Supreme PLUS Low VOC Basecoat colors. It is designed to accommodate fast air-dry and quick bake conditions, increasing the productivity and profitability for the repair facility. It is ideal for spot and panel repairs with easy application and good appearance. Materials: Clearcoat: LC4800 Hardeners: LH401 LH405 LH415 Flex Agent 892 Basecoat: Supreme PLUS Low VOC Basecoat 420 gms/liter (3.5 lbs/gal) VOC Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. LC4800 is not covered by a warranty and should not be used with warrantable systems US Rev. 11/21/14 T E C H N I C A L D A T A LC4800 Low 2.0 VOC Express Clear 250 gms/liter (2.1 lbs/gal) VOC Flexed S Mixing ratio: 4:1 8:2:1 Clear 4 parts LC4800 8 parts LC4800 Hardener 1 part LH401, LH405 or LH415 2 parts LH401, LH405 or LH415 Flex Agent — 1 part 892 Potlife at 68°F/20°C 2 - 3 hours 2 - 3 hours Spray viscosity Ford #4 @ 68°F/20°C 13 - 15 seconds 13 - 15 seconds Gravity gun nozzle HVLP 1.1 - 1.3 mm 1.1 - 1.3 mm Spray pressure HVLP at the cap 9 - 10 psi 9 - 10 psi Application 2 wet coats 2 wet coats Flash-off time @ 68°F/20°C 5 minutes between coats 5 minutes between coats Film build 2.0 - 2.5 mils 2.0 - 2.5 mils Coverage 610 sq. ft./gal @ 1.0 mil 650 sq. ft./gal @ 1.0 mil 68°F/20°C 15 minutes dust free; 4 hours to handle 20 - 25 minutes dust free 140°F/60°C 30 minutes; may be handled or polished after cool down 30 minutes; may be handled or polished after cool down Infra red short wave 8 - 10 minutes 8 - 10 minutes Infra red medium wave N/A N/A Wet by Hand 1500 or Finer 1500 or Finer Dry by Hand 1500 or Finer 1500 or Finer Dry by Machine 1500 or Finer 1500 or Finer VOC as packaged 228 gms/liter (1.9 lbs/gal) 228 gms/liter (1.9 lbs/gal) VOC as applied 240 gms/liter (2.0 lbs/gal) 250 gms/liter (2.1 lbs/gal) Comments Wait 8 hours before sanding, compounding or recoating. Drying: Sanding: Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. MISCELLANEOUS 892 Flex Agent Description: Limco 892 Flex Agent is a urethane additive that gives flexibility to Limco Undercoats, Topcoats and Clearcoats. Limco 892 is formulated to resist fading, stone chipping and chemical staining while increasing the durability and flexibility of most interior and exterior parts. Mixing: When finishing flexible parts, refer to the appropriate technical data sheets for detailed processing information. Undercoat: • 800K (4 parts 800K: 1 part LH810 or LH820: 1 part 892) • 800K tinted wet-on-wet sealer (1 part 800K: 1 part LB base without mixing clear; then 4 parts tinted 800K: 1 part LH810 or LH820: 1 part LR21 or LR25: 1 part 892) • LP610 primer surfacer (4 parts LP610: 1 part LH401, LH405 or LH415: 1 part LR21 or LR25: 1 part 892) • LP610 sealer (4 parts LP610: 1 part LH401, LH405 or LH415: 2 parts LR21 or LR25: 1 part 892) • LS800 (4 parts LS800: 1 part 892: then mix according to appropriate tinted or untinted mix ratio, see LS800 tech sheet for complete mixing instructions.) Topcoat: • Limco Acrylic Enamel (Limco 2) (8 parts LB base without mixing clear: 1 part 892; then 8 parts color: 1 part LHF, LHM or LHS: 4 parts LR10, LR11, LR12, LR13 or LR15) • Limco Urethane (Limco 3) (8 parts color: 1 part LH310 or LH320: 4 parts LR10, LR11, LR12, LR13 or LR15: 1 part 892) • Limco Low VOC Urethane (Limco 3) (4 parts color: 1 part LHF, LHM or LHS: 2 parts LR21 or LR25: 1 part 892) • Supreme PLUS Urethane Single Stage National Rule (4 parts color: 1 part LHF, LHM or LHS: 1 part 892: 1 part LR10, LR11, LR12, LR13 or LR15) • Supreme PLUS Low VOC Urethane Single Stage 340 gms/liter (2.8 lbs/gal) VOC (8 parts color: 3 parts LH401, LH405 or LH415: 2 parts 892: 2 parts LR21 or LR25) • Supreme PLUS Low VOC Urethane Single Stage 420 gms/liter (3.5 lbs/gal) VOC (8 parts color: 3 parts LH401, LH405 or LH415: 2 parts 892: 2 parts LR10, LR11, LR12, LR13 or LR15) Clearcoat: • LC4000 (4 parts clear: 2 parts LHF, LHM or LHS: 1 part 892) • LC4100 (4 parts clear: 2 parts LHF, LHM or LHS: 1 part LR10, LR11, LR12, LR13 or LR15: 1 part 892) • LC4200 (8 parts clear: 2 parts LH401, LH405 or LH415: 1 part 892) • LC4500 (4 parts clear: 2 parts LHF, LHM or LHS: 1 part LR10, LR11, LR12, LR13 or LR15: 1 part 892) • LC4800 (8 parts clear: 2 parts LH401, LH405 or LH415: 1 part 892) Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. For information on preparing plastic parts, refer to “Standard Preparation for Plastic Parts” in the APPLICATION PROCEDURES section of the Limco Technical Manual. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. US Rev. 8/1/13 MISCELLANEOUS LE800 Fisheye Eliminator Description: Limco LE800 Fisheye Eliminator is specially developed for use in Limco Single Stage Topcoats, Supreme PLUS Single Stage Topcoats and Limco Clearcoats. Mixing: Add up to 1 ounce (approximately 28 grams) of Limco LE800 Fisheye Eliminator per ready for use gallon of topcoats and clearcoats. Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. Only use if fisheyes or craters are encountered. DO NOT use in any undercoats or basecoats. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. US Rev. 8/1/13 MISCELLANEOUS LF10 Flattening Agent Description: Limco LF10 is a flattening agent that may be added to all Limco Single Stage Topcoats, Supreme PLUS Single Stage Topcoats and Limco Clearcoats for gloss reduction. Limco LF10 mixes easily and allows flattening to the extent desired. Mixing: Stir product thoroughly for 5 - 10 minutes before using. Add 25% - 50% of LF10 to the catalyzed (paint and hardener, no reducer) Limco mixture. Additional reduction is optional. Ensure proper flash-off periods are observed when spraying flattened products to prevent additional gloss. Polishing finishes containing LF10 will cause gloss levels to increase. Remarks: Always check local VOC laws to ensure that the use of these Limco products is compliant in your area. DO NOT use LF10 in any Basecoat color. Cannot be mixed with any Low VOC Limco product and still be VOC compliant. RFU formulas for Limco Clearcoats are available. Materials described are for application by professional trained personnel only using proper equipment. Products may be hazardous & should be used according to label directions & technical data information. Appropriate respiratory protection should be worn at all times while products are in use—read product label and Material Safety Data Sheet (MSDS) for specific details. Statements & methods described are based upon the latest standard of technology known to the manufacturer. Application procedures cited are suggestions only & are not to be interpreted as warranty for events resulting from their use. Dilution ratios are intended to provide maximum performance within the typical Volatile Organic Compound (VOC) restriction for product use. Specific VOC limits need to be referenced to verify local compliance. Altering the solvent or dilution ratio may impact VOC compliance. User is solely responsible to ensure product use and application is in accordance with all applicable regulatory, legislative, and municipal requirements. US Rev. 8/18/15