Family of Products

Transcription

Family of Products
®
Family of Products
Hydrophobic
Yellow
Aspheric
Preloaded
Lens-prep+ Power Range: 4.0 to 26.0 in 0.5D increments.
Available
With
Lens-prep™+
Design:
Overall Diameter:
Optic Diameter:
A-Constant**:
Refractive Index:
AC-Depth**:
*Glass Transition Temperature
Design:
Angulation:
Material:
Design:
Overall Diameter:
Optic Diameter:
A-Constant**:
Refractive Index:
AC-Depth**:
Angulation:
Optic
Available
With
Lens-prep™+
Optic
Bi-Convex
13.0mm
6.0 or 6.5 mm
118.2mm
1.49
5.1
Haptics:
Modified C
5º
PVDFu
u
Polyvinylidene Fluoride
Power Range: 4.0 to 34.0D (in 0.5D increments)
Bi-Convex
13.0mm
6.0mm
118.1mm
1.49
5.1
5º
Power Range: 4.0 to 34.0D (in 0.5D increments)
** A-Constant and AC-Depth are estimated and not based on clinical data.
The P.U.R.E.™ System
Precision UnResolved-materials Extraction™
P.U.R.E.™ is a unique molecular cleaning method developed by Aaren Scientific to remove materials and
extraneous processing materials found in hydrophilic lenses that are not fully polymerized. Aaren lenses
that go through the P.U.R.E.™ System have enduring optical clarity and enhanced biocompatibility. ALL
Aaren hydrophilic acrylic lenses are being treated with this proprietary system. Purity is verified by routine
use of high sensitivity mass spectrometry (MS) chemical analysis.
Over 1,000,000 P.U.R.E.™ lenses sold.
* A-Constants and AC-Depths are estimated and not based on clinical data.
u Polyvinylidene Fluoride
Benefits of Heparin Surface Modification
• Reduces postoperative inflammatory responses in the early postoperative period.**
• Results in reduced foreign-body reactions as measured by specular microscopy and slit-lamp
examination, especially in the early postoperative period.**
• Appears to be a valuable tool to decrease implant-associated bacterial endophthalmitis.**
• HSM posterior IOLs result in less cellular response observed one year after extra-capsular
cataract extraction.**
• Patients who are diabetic or have glaucoma can definitely benefit from an HSM acrylic IOL
compared to a non-HSM PMMA IOL, according to a multi-center study.**
(**Statements taken from industry articles on file.)
u Polyvinylidene Fluoride
* A-Constants and AC-Depths are estimated and not based on clinical data.
™
Introducing
and
Aspheric Lenses...
Traditional spherical IOLs are subject to aberrations that result in slightly distorted images on the retina particularly at large pupil diameter. This is because light rays that enter the eye peripherally undergo stronger
refraction than those that enter centrally. One of the benefits of Aaren PAL™ aspheric lenses is improved
contrast sensitivity, especially in low
MTF in Eye Model with Simulated Human Cornea
MTF in Eye Model with Simulated Human Cornea
5mm Aperture with 0.5mm Lens Decentration*
5mm Aperture with 1.0mm Lens Decentration*
light (large pupil) conditions.
The optics of Aaren Scientific’s
Precision Aspheric Lenses (PAL™)
are designed to compensate for
the aberrations of the human eye
to achieve exceptional optical
performance - even in instances of
naturally occurred IOL misalignment.
MTF
1.0
1.0
0.8
0.8
0.6
MTF
0.6
0.4
0.4
0.2
0.2
0.0
0
10
20
30
40
50
60
70
80
Spatial Frequency (cycles/mm)
0.0
90 100
0
10 20 30 40 50 60 70 80 90 100
Spatial Frequency (cycles/mm)
(100 cycles/mm equivalent to 20/20 vision)
MTF (Modulation Transfer Function)
analysis shows the significantly
improved image quality of an Aaren
PAL™ hydrophilic lens to a typical
aspheric lens, under various degrees
of decentration and tilt. In addition,
the MTF of PAL is comparable to or
better than that of a spherical optic
under these same conditions.
MTF in Eye Model with Simulated Human
Cornea 5mm Aperture with 0.5mm Lens
y-decentration and 7degrees x-tilt*
1.0
1.0
0.8
0.8
MTF
MTF
0.6
0.6
0.4
0.4
0.2
0.2
0.0
MTF in Eye Model with Simulated Human
Cornea 5mm Aperture with 0.5mm Lens
y-decentration and 7degrees y-tilt*
0
10 20 30 40 50 60 70 80 90 100
Spatial Frequency (cycles/mm)
0.0
0
10 20 30 40 50 60 70 80 90 100
Spatial Frequency (cycles/mm)
*Best Focus defined at 3mm aperture prior to determining MTF at 5mm.
PAL™ optics are
now available on
most Aqua-Sense®
and BioVue® lens
models.
For flexible haptics,
we recommend our SP
lens series.
For firmer haptics,
please try our XP series
Standard Power Range: 4.0 to 30.0 in 0.5D increments.
* Power Range, Low: 0.5 to 3.5 in 0.5D increments.
** Power Range, Negative: -0.5 to -12.0 in 0.5D increments.
“A” Constants and AC Depths are estimated
and not based on clinical data.
Viscoelastics and
Tension Rings
27 G
cannula
Aaren Scientific® Bio-Clear® is a high-quality,
high-molecular weight viscoelastic made
from highly purified hyaluronic acid from
rooster comb.
PMMA Capsular Tension Rings
Precision medical devices for insertion in the capsular bag
Suggested Indications:
• Weak or missing zonules
• IOL subluxation
• Expected complications during
phaco surgery
Advantages:
• Maintains circular expansion of
capsular bag
• Stabilizes conditions during surgery
• Improves IOL centration
• Minimizes risk of capsular fibrosis
• Prevents capsular collapse
®
4290 East Brickell Street, Bldg. A
Ontario, CA 91761 USA
Tel: (909) 937-1033 • Fax: (909) 937-1088
E-mail: [email protected]
Web: www.aareninc.com
P/N: 3227 J
Copyright © 2009 Aaren Scientific Inc.® All Rights Reserved.