Inpond All-in-one filter 1400
Transcription
Inpond All-in-one filter 1400
Blagdon Inpond Instructions AW.qxd Established over 40 years ago, Blagdon are committed to producing a comprehensive range of high quality, easy to use, pond equipment. An ongoing programme of research and development ensures excellent performance and value for all their customers. This product excellence is demonstrated by Blagdon’s award winning range of water gardening equipment. As a result Blagdon’s reputation for quality is unrivalled amongst experienced pond gardeners and retailers alike. Blagdon - The Pond Masters The name you can rely on Interpet Dorking, Surrey, RH4 3YX Leaflet Code: BG Inpond 1-a 17/12/10 10:05 Page 1 inpond all-in-one filter 1400 Blagdon Inpond Instructions AW.qxd 17/12/10 10:05 Page 3 inpond all-in-one filter 1400 Congratulations on buying a Blagdon Water Garden Filtration System. Manufactured with advanced technology to create a clean and healthy pond for your fish. IMPORTANT Please attach proof of purchase to this manual and file in a safe place. 1 Blagdon Inpond Instructions AW.qxd 17/12/10 10:05 Page 5 CONTENTS GETTING TO KNOW YOUR INPOND FILTER 30 Getting to know your Inpond filter Parts descriptions / spares codes - with exploded diagram 3 Technical specifications 5 Pump performance / flow chart 5 Installation 6 Electrical installation Installing Inpond Filter 28 27 8 6 25 7,8 & 9 Maintenance and cleaning 10 Cleaning 10 Step by step guides 11 Routine maintenance 11 Monthly maintenance 12 Annual maintenance 13 Winter storage 13 36 Troubleshooting and maximise performance 27 38 6 BLACK 5 14 37 4 33 14 & 15 23 3 Faults - problem procedure 26 7 GREEN Troubleshooting 31 29 3-4 36 16 Consumer advice contact details 16 Returning faulty pumps 16 Guarantee 17 22 21 2 24 32 20 19 35 9 18 11 34 1 2 10 12 13 14 15 16 17 3 Blagdon Inpond Instructions AW.qxd 17/12/10 10:05 Page 7 GETTING TO KNOW YOUR INPOND FILTER 4 No. Part Description Spare Code 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 35. 36. 37. 38. Filter body UVC Contact camber Polymer wool pad Polymer wool cartridge Medium foam Coarse Foam Filter lid Locking handle Locking cap Double threaded attachment 11/2” Connecting pipe Pump locking nut 11/2” Impeller cover O ring Impeller complete Pump motor unit Pump back panel Light level sensor Automatic LED Spot light O ring LED lamp LED lamp cover clear LED lamp screw cap Ball Joint 30cm Telescopic extension pipe 20cm extension pipe Control valve & diverter Fountain attachment Water bell large Daisy super Daisy Pump cable Low voltage transformer Blanking screw cap Ceramic media Ceramic media Screw on hosetails Silicone hose Control valve hose attachment N/A N/A 1051166 N/A 1051170 1051170 N/A N/A N/A N/A N/A N/A N/A N/A 1017800 N/A N/A N/A 1051330 N/A N/A N/A N/A N/A N/A N/A N/A N/A 1017763 1017763 1017763 N/A 1017763 N/A N/A 1051187 N/A N/A N/A GETTING TO KNOW YOUR INPOND FILTER Pump performance / flow chart Tech Specification: Cable Fitted 10 metres Voltage 12V Pump Watts 10 700ltr (154 gal) Safety Rating IP68 1.25m max head (4.1”) Maximum Depth _ 1.25 metres CC 12v Low voltage Maximum Lift 1.25 metres / 4’1” IP56 Weatherproof transformer 10m of low voltage cable 10w IP68 Lift Flow rates lph 2.0 metres - 1.5 metres - 1.0 metres 300 lph 0.5 metres 520 lph 0.0 metres 700 lph LED Photo sensor activated 0.76w Flow is given as optimum rate Specification chart 1400 1400 1400ltr/307.95gal 700ltr/153.97gal 700ltr/153.97gal 525ltr/116gal 262ltr 58gal 25mm/1” 5 Blagdon Inpond Instructions AW.qxd 17/12/10 10:05 Page 9 INSTALLATION Electrical installation The power supply must meet the specifications on the product. The pump is intended to be used with either a weather-proof cable connector or permanently connected to the fixed wiring in the main system other than by means of a plug and socket. The cores in the supply cable are coloured in accordance with the following code: Brown = Live, Blue = Neutral, Green/Yellow = Earth. The electric cable is permanently connected and sealed in the motor body. If the supply cable is damaged the pump must not be used. Do not use the supply cable to lift the pump as this may cause damage. WARNING - THIS PUMP MUST BE EARTHED A Residual Current Device (RCD), also know as the Residual Current Circuit Breaker (RCCB), with a tripping current not exceeding 30mA must be installed in the supply circuit. A means of disconnection from the supply having a contact separation of at least 3mm in all poles must be incorporated in the fixed wiring. INSTALLATION Locating your Inpond All-in-one Filter The Inpond pump and filter should be located on a firm and level base in the pond/water feature in a depth of at least 10cm, but no more than 1.25m. It is advisable to keep the pump off the bottom of the pond to avoid silt entering the pump causing excessive wear and increasing pre-filter cleaning. Fountain Make sure there is ample cable from mains supply. Place filter in desired location. Add Fountain extension pipes so fountain head is above surface of the pond. Fountain height can now be adjusted, see ‘Adjusting flow control’ diagram below. See "Getting to know your Inpond" for parts and descriptions. ADJUSTING FLOW CONTROL Turn clockwise to increase anti-clockwise to reduce flow. BELL FOUNTAIN Adjust bell by moving head higher for small bell and lower for a wider bell shape. For permanent installations to the mains supply, it is necessary to conform to the regulations of the local electricity authority and this would include the use of a metal or plastic conduit to protect the cable. Attention has been drawn to the fact that special rules may exist concerning the installation of your pond pump (i.e. local building regulations). These pumps must not be used in swimming pools, or areas where people are in contact with the water. Always disconnect the mains electricity supply whilst the equipment is being installed, repaired, maintained or handled. Consult a qualified electrician if in any doubt about wiring this product to the main supply. Tip: Ensure that any fountain or feature fitted does not empty water out of pond/water feature. Water Feature Install as for Fountain. Depending on water feature to be supplied, your Inpond all-in-one filter can be used with the flow control and the 1/2" hose fitting or 3/4" hose fitting. Hose clips should be used to secure hose. Warning - The Inpond pump is provided with a thermal cut out that temporarily switches off the pump in case of overheating and the pump may automatically restart. 6 7 Blagdon Inpond Instructions AW.qxd 17/12/10 10:05 Page 11 INSTALLATION INSTALLATION IMPORTANT CONVENIENT INSTALLATION The Inpond All-in-one filter can be installed either powering a waterfall or fountain. Waterfall option The outlet hose should be smooth bore (not corrugated) pipe installed over as short a distance as possible with no kinks or bends. We recommend that Blagdon smooth bore clear hose or Blagdon heavy duty smooth bore black hose are used. Fountain option WATERFALL MAX 70cm HOSE Inpond Filter TYPICAL INSTALLATION MIN 40cm Inpond Filter The recommended hose size for your Inpond filter is stated in the filter performance and specification chart. /1” CONNECTING OUTLET HOSES FOUNTAIN Recommended Always secure hose with a jubilee clip. Warming the hose in a bucket of boiling water can aid fitting. Always ensure that the smaller diameter hosetail is cut off and removed to prevent reduced filter performance. Use the shortest possible hose lengths to minimise flow restrictions. Avoid folds and kinks in the hose, which will reduce flow and filter performance. 8 9 Blagdon Inpond Instructions AW.qxd 17/12/10 10:05 Page 13 MAINTENANCE & CLEANING MAINTENANCE & CLEANING Opening and locking filter handle Warning - Failure to carry out routine maintenance leaving the pump under reduced or no flow conditions for long periods (i.e. blocked pre-filter) will result in a shorter pump life and will invalidate the guarantee. Easy lift integrated locking handle Locked Note the handle is in the locked position The Blagdon Inpond all in one pump is centrifugal with a magnetic impeller movement driven by a watertight synchronous motor. They require minimum cleaning, only periodic cleaning of the pre-filter and impeller is necessary. Routine Maintenance Carry out routine maintenance when filter flow is visibly reduced. Locked 1. Switch off electricity. 2. Remove filter from pond (do not use the cable to lift the pump.) * Ensure the filter is not carried by the pump cable. HOW IT WORKS - FLOW DETAIL Flow control Inlet grills Handle is in the central position. This will enable the filter and pump to be carried in and out of the pond. Automatic LED spot light Unlocked Coarse foam The handle is in the unlocked position allowing the filter media to be removed and cleaned. Low voltage Pump Locking handle Foams may be cleaned vigorously under a running tap or hose. Medium foam Polymer wool pad cartridge UVC contact chamber Inlets Ceramic biomedia Inpond UVC upgrade is available as a Blagdon product. Product code: 1051309 10 Adding Interpet Bio Start after filter maintenance will help replenish these beneficial bacterial populations and is highly recommended during the first two months of operation when the filter is slowly being colonised. Ceramic bio media These will only need very occasional cleaning (once per year), but must be rinsed in pond water to prevent damaging the beneficial bacteria which help maintain a healthy pond. 11 Blagdon Inpond Instructions AW.qxd 17/12/10 10:05 Page 15 MAINTENANCE & CLEANING MAINTENANCE & CLEANING LED Automatic Photo Sensor Polymer wool cartridge /2“ hose fitting 1 The polymer wool pad may be washed a limited number of times before it starts to lose efficiency and blocks rapidly. Automatic LED spot light Ball joint LED automatic sensor Replacement packs of polymer wool will be available from your retailer and are quick and easy to replace. Pump If the LED light is not required you can permanently remove the lamp (see removing lamp section page). See page 11 on how to remove the cartridge easily from the Inpond filter. Active hinge Polymer wool cartridge - detects when light levels are low/dusk The LED automatic sensor is positioned on top of the motor body between the outlet and the lamp. Ensure this is kept clean from dirt and algae as it needs sufficient light to activate correctly. This extremely efficient lamp uses less than 1 watt of electricity which automatically turns off at dawn. Annual maintenance of the filter Check for wear Polymer wool pad Once a year you should dismantle your Inpond filter. Dismantle the filter examining all the parts for wear or damage, replacing any parts showing obvious signs of wear and/or damage (see getting to know your filter for replacement codes and parts descriptions on page 2). Annual maintenance of the pump 23 Removing LED Lamp 22 Replacing or removing the lamp can be easily done by unscrewing part 23 from the lamp holder (part 19) then part 22 will be able to be removed. Allowing the lamp to be disconnected (part 21). 20 21 19 Dismantle pump and examine all parts for wear or damage, replacing any parts that show obvious wear and/or damage (see getting to know your Inpond filter for parts/description and replacement parts codes). Particular care should be taken to examine the cable entry points. Winter Storage Pump IMPORTANT - Ensure that the mains supply is switched off and the power isolated before removing the lamp cover. 12 Once a year you should service your pump. The Inpond filter and pump can be run in the pond during the winter but care should be taken to ensure that it is fully immersed and cannot freeze solid. If the pump is not used during the winter follow the annual maintenance procedure and store frost-free in the house or garage until spring 13 Blagdon Inpond Instructions AW.qxd 17/12/10 10:05 Page 17 TROUBLESHOOTING TROUBLESHOOTING Inpond Filter Inpond Pump Filter leaks Problem • Check that the filter outlet nut and O ring have been correctly assembled and that they are hand tight. Low flow from pump • PTFE tape may be needed to give a water tight seal and should be applied to utlet hosetails. 2. Follow monthly cleaning procedure. • Always secure the filter outlet hose with a jubilee clip. 1. Follow routine cleaning procedure if no improvement. 3. Ensure pipe work is not blocked, leaking or is laid so that it gets crushed or kinked. Cloudy/brown water 4. Keep the height that water is to be pumped from the water surface (called Head) to a minimum. The higher the head the lower the flow rate and the more wear on the pump. • The flow rate / pond turnover is to high or to low. Check that you have correctly calculated the pond volume and that pump flow rate is within limits. 5. Use the largest diameter, smoothest bore pond hose over the shortest distance and keep hose fittings to a minimum. This removes frictional loss of flow and so increases pump flow rates. • The filter is not being supplied with water 24 hours a day. Do not turn off your pump. Continuous running is needed to maintain a clean and healthy pond. Poor Fountain performance • Insure that the filter is installed on a flat and level base. • The filter foam pads are insufficiently blocked to trap the fine waste. Treat with Interpet Clear Pond treatment. • The water is extremely dirty, remove pond waste and leaves - carry out a partial water change. • Filter is incorrectly sized - refer to filter performance and specification chart. • The filter foams have not been positioned or replaced correctly,ensure that the foams fit tightly within the filter chamber. • Reduced height. DAISY • Jets blocked. To clean, remove head and rinse. Or in hard water areas, use Blagdon Pond Pump Cleaner. Clean flow adjuster and fountain head. Wash under a tap or hose. Blagdon Pond Pump Cleaner should be used to remove lime scale build-up/waste (see diagram) for improved results. No flow from pump 1. Check power supply is on. 2. Check fuse and wiring (SEE ELECTRICAL INSTALLATION). 3. Follow low flow procedure as above. If none of the above works contact Interpet (Blagdon) Consumer Advice Department (See Faults problem procedure Page 16). 14 15 Blagdon Inpond Instructions AW.qxd 17/12/10 10:05 Page 19 IMPORTANT FAULTS - PROBLEMS PROCEDURE Before returning your Inpond Filter to your dealer or contacting our Consumer Advice Department, please carry out the following steps. This will solve most problems quickly and easily. 1. Ensure electrical procedures have been followed fully. Check fuses and any cable connectors/switch boxes. 2. (a) Follow routine maintenance procedure fully. (b) Check location and connecting your pump details including flow rates. (c) Ensure that your pond volume and pump flow rate meet the maximum pond size recommended for the filter model on the filter performance and specification chart. (d) Follow troubleshooting guide. 3. If there is a mechanical breakdown of the filter or UVC, return to the point of purchase for inspection and advice (You will need proof of purchase). CLEARWATER GUARANTEE The Clearwater guarantee will be honoured for 1 year after proof of purchase. Clearwater is guaranteed to a depth of 1m, so that fish are clearly visible. Clearwater is guaranteed provided: • You follow all instructions as above. • Your filter is within the performance guidelines stated. • You consult the Consumer Advice Line and follow any advice to correct the situation. See details below. Refunds can only be authorised by Interpet Blagdon. CONSUMER ADVICE CONTACT DETAILS Interpet (Blagdon) Consumer Advice Department Vincent Lane, Dorking, Surrey RH4 3YX Telephone: 0845 226 7437 (Monday to Friday 10am to 4pm except Bank Holidays - Times may vary) Fax: 01306 876712 E-mail: [email protected] www.blagdonthepondmasters.co.uk 16 GUARANTEE This product is guaranteed against defects in material and workmanship for 2 years from the date of purchase, under normal usage. The guarantee DOES NOT APPLY in case of improper use, negligence, lack of maintenance or accidental damage to either the filter or UVC. If the filter or UVC fails due to a manufacturing fault within this period it will be either repaired or replaced free of charge. Liability is limited to replacement of the faulty product only; no other costs will be reimbursed. This guarantee is not transferable and does not affect your statutory rights. This guarantee does not confer any rights other than those expressly set out above. This guarantee does not cover the filter foams or UVC bulb, which will need replacing when worn or every 6 months. If any parts are needed, spares are available from your retailer. Environment friendly disposal You can help protect the environment. Please remember to respect the local regulations: hand in the non-working electrical equipments to an appropriate waste disposal centre.