ACCESSORIES - nihonkohden.de

Transcription

ACCESSORIES - nihonkohden.de
Fighting Disease with Electronics
ACCESSORIES
PATIENT MONITORING
2 0 1 3
2
Introduction
www.nihonkohden.net
Introduction
Dear Customer,
For more than 60 years NIHON KOHDEN has been one of Japan’s leading players in medical technology development and manufacturing and has subsidiaries and representative offices in Europe, the US, as well as in the Middle and Far East.
“Fighting Disease with Electronics“ – our corporate philosophy – reflects the high standards we have set ourselves in combating
disease by developing medical systems, contributing to higher quality of life for patients.
Our large product range of accessories and consumables is known for its outstanding quality, ease of use and reliability. Please
note, that only the use of original NIHON KOHDEN approved accessories and consumables guarantee optimal examination results
and make an important contribution towards ensuring that your device will continue to function impeccably and reliably even in
years to come, while preserving the device’s features and functional capabilities.
As your partner in patient care, NIHON KOHDEN provides only tested and approved product solutions from standard vital signs
monitoring such as ECG, SpO2, NIBP or Temperature measurement to specific parameters like Capnography, Anesthesia Gas, EEG,
TOF, IBP or ICP Measurement. Our commitment to ensure continually highest quality allows you the best care of your patients and
enhances your devices performances.
NIHON KOHDEN invites you to discover the quality and features of our complete accessories and consumables portfolio in this
catalogue. Call today for more information or order directly!
Best regards,
NIHON KOHDEN EUROPE GmbH
Dirk Mehlhorn
Kristin Baar
Director Production & Support Center
Product Manager Accessories & Consumables
3
www.nihonkohden.net
Content
Accessories for Patient Monitors
User Guide
7
A Novel Technology to Non-Invasively Measure Continuous Cardiac Output from ECG and SpO2
8
Smart Cable TM Technology
8
Highest Safety and Quality Standards
9
1
ECG Measurement
10
1.1
1.1.1
1.1.2
1.2
1.2.1
1.2.2
ECG Cables
ECG 3/6-Lead Cables
ECG 10-Lead Cables
ECG Electrodes
ECG Electrodes for Adults
ECG Electrodes for Children, Infants & Neonates
11
12
13
14
15
16
2
SpO2 Measurement
17
2.1
NIHON KOHDEN SpO2 Cables
SpO2 Adapter Cable for current patient monitors with rectangular connector
SpO2 Adapter Cable for older patient monitors with round connector
SpO2 Adapter Cable for OLV-2700/3100 & OPV-1500
Dual SpO2 Adapter Cable
NIHON KOHDEN SpO2 Probes
Reusable SpO2 Probes
Disposable SpO2 Probes
Disposable SpO2 Probes 24 pcs/box - cable length: 0.8 m
Disposable SpO2 Probes 24 pcs/box - cable length: 1.6 m
Disposable SpO2 Probes 5 pcs/box - cable length: 0.8 m
Disposable SpO2 Probes 5 pcs/box - cable length: 1.6 m
Disposable Multi-Site SpO2 Probes 5 pcs/box - cable length: 2.0 m
Cables for Nellcor & Masimo SpO2 Probes
18
2.1.1
2.1.2
2.1.3
2.1.4
2.2
2.2.1
2.2.2
2.2.2.1
2.2.2.2
2.2.2.3
2.2.2.4
2.2.2.5
2.3
18
18
18
18
19
21
23
23
24
24
26
27
28
4
Content
www.nihonkohden.net
3
NIBP Measurement (Non-Invasvie Blood Pressure)
30
3.1
3.2
3.3
3.4
NIBP Air Hoses
Reusable Standard NIBP Cuffs
Reusable YAWARA NIBP Cuffs
Disposable NIBP Cuffs
31
32
33
34
4
Temperature Measurement
36
4.1
4.2
Standard Temperature Measurement
Measurement of 2 Additional Temperatures
37
37
5
CO2 Measurement (Capnography)
38
5.1
5.1.1
5.1.2
5.1.3
5.2
5.2.1
5.2.2
5.2.2.1
5.2.2.2
CO2 Mainstream
Intubated expired CO2
Intubated expired and inspired CO2
Intubated and non-intubated expired CO2
CO2 Sidestream (Covidien)
Combination out of sampling-line and Airway Adapter
Nasal Lines for non-intubated patients
Nasal Lines for non-intubated patients without oxygen supply
Nasal Lines for non-intubated patients with oxygen supply
40
40
41
42
44
44
44
44
45
6
Anesthesia-Gas-Measurement
46
6.1
6.2
Accessories for AG-920 & GF-110/120R
Accessories for GF-210/220R
47
48
7
Spirometry - Flow / Paw Measurement
50
7.1
7.2
Flow / Paw Measurement AF-900P
Flow Measurement with GF-120PA/GF-220R
51
51
5
Content
www.nihonkohden.net
8
FiO2 Measurement & Respiration
52
8.1
8.2
FiO2 Measurement
Respiration
53
53
9
IBP & ICP Measurement (Invasive Blood Pressure & Intracranial Pressure)
54
9.1
9.2
9.3
9.4
IBP Transducer Cable with Direct Connection
IBP Transducer Cable with Adapter Cable K952
ICP Standard Adapter Cable
ICP Sensor Cable for BSM-9100
55
56
58
58
10
Cardiac Output (C.O.)
59
11
EEG Measurement
62
11.1
11.2
11.3
2-channel EEG
8-channel EEG
Further EEG Accessories
63
64
65
12
BIS & TOF Measurement
68
12.1
12.2
12.2.1
12.2.2
BIS Measurement
TOF Measurement
Mandatory Accessories for TOF Interface
Further TOF Accessories
69
69
69
69
13
Further Accessories
72
13.1
13.2
13.3
13.4
13.5
Recording Paper
Batteries & Battery Charger
Analog Output Cable
Power Cable
Pens
73
74
75
75
75
6
Content
www.nihonkohden.net
Accessories for Transmitters
14
Accessories for Transmitters
76
14.1
14.1.1
14.1.2
14.1.3
14.1.4
14.1.5
14.2
14.2.1
14.2.2
14.2.3
14.2.4
14.2.5
14.3
14.3.1
14.3.2
14.3.3
14.3.4
14.3.5
14.3.6
ECG Measurement
ECG Cables
ECG 3-Lead Cables for ZS-910/-920/-930/-530PG; ZM-920/-930/-940PG
ECG 6-Lead Cables for ZM-920/-930/-940PG
ECG Electrodes
ECG Electrodes for ZS-910/-920/-930/-940/-530PG; ZM-920/-930/-940PG
SpO₂ Measurement
SpO₂ Probes
SpO₂ Measurement with ZS-930/-940/-530PG; ZM-930/-940PG
Reusable SpO₂ Probes
Disposable SpO₂ Probes
NIBP Measurement (Non-Invasive Blood Pressure)
NIBP Measurement with ZS/ZM-940PG
Reusable NIBP Cuffs for attaching transmitter to the arm
NIBP Air Hoses for ZS/ZM-940PG
Reusable Standard NIBP Cuffs
Reusable YAWARA NIBP Cuffs
Disposable NIBP Cuffs for Infants & Children
Disposable NIBP Cuffs for Adults
77
78
79
79
80
83
84
86
86
86
93
94
94
94
95
96
97
97
15
Bags, Straps & Holder for Transmitters
98
Accessory Order Form
102
Index as per Supply Code
102
Index as per Model Code
104
Distributor Contact Details
106
7
User Guide
www.nihonkohden.net
User Guide
Care of Environment
NIHON KOHDEN is making every possible effort to ensure that the actions of the company and its employees contribute to
preserving the environment. In order to avoid paper resources, we decided a more environment friendly approach which allows us
to update the catalogue more frequently in the future. Therefore the new accessories and consumables catalogue was designed
for view on your computer. It allows you to zoom pictures in order to see more details of the product. If you need indeed certain
chapters in print version, you can easily select and print them.
Find the right accessories in the catalogue
You do not know exactly which article you need for your examination?
Following this user guide you will find the content of this catalogue which is organized into parameter categories. In a particular
category you will see a list of accessories and consumables with corresponding supply codes, model codes, descriptions and
pictures. If you are not sure if one of the listed products will fit to your requirements, please contact us or one of our regional
representatives.
You already know the article that you need for your examination?
In the index of the catalogue , from page 102 to page 103, the articles are listed alphabetically as per supply code; from page 104 to page 105,
the products are listed alphabetically as per model code. They will help you to find directly the according product page.
If you are using the PDF version, simply use the “search function” of this by entering the description, supply or model code.
Or just click on the related chapter on the left side of the document.
Order information
To order NIHON KOHDEN accessories and consumables or to get more information, please refer to the indicated regional
NIHON KOHDEN representatives below.
For your convenience, we have a printable order form at the end of this catalogue so that you can fax in your order directly or
mail/e-mail it to us. Please make sure to fill out all requested information as well as the required supply code and according
quantity. Please check the general terms and conditions including delivery time, payment and general warranty with your
responsible regional NIHON KOHDEN representatives:
For Germany, Austria, Switzerland and Benelux
NIHON KOHDEN EUROPE GmbH, Vertrieb Deutschland
Albert-Einstein-Ring 9, 14532 Kleinmachnow, Deutschland
Fax: +49 (0) 33203/573-19, E-Mail: [email protected]
For Spain and Portugal
NIHON KOHDEN IBERICA S.L.
C/Ulises, 75A, 28043 Madrid, Spain
Fax: +34 91 300 46 76, E-Mail: [email protected]
For United Kingdom
NIHON KOHDEN UNITED KINGDOM Ltd.
Tolworth Tower – 19th Floor, Ewell Road, Surbiton,
Surrey KT6 7EL, United Kingdom
Fax: +44 (0) 20 83 90 46 75, E-Mail: [email protected]
For France
NIHON KOHDEN FRANCE SARL
8, rue François Delage, 94230 Cachan, France
Fax: +33 (0) 1 49 08 93 32, E-Mail: [email protected]
For Italy
NIHON KOHDEN ITALIA S.r.l.
Via Fratelli Bronzetti, 28, 24124 Bergamo, Italy
Fax: +39 (0)35-232546, E-Mail: [email protected]
For all other European Countries, Russia, Turkey and Israel
NIHON KOHDEN EUROPE GmbH
Raiffeisenstraße 10, 61191 Rosbach v. d. H., Germany
Fax: +49 (0) 6003/827-599, E-Mail: [email protected]
esCCOTM & Smart Cable™Technology
8
www.nihonkohden.net
A Novel Technology to Non-Invasively Measure
Continuous Cardiac Output from ECG and SpO₂
Estimated Continuous Cardiac Output (esCCO) is a new technology to determine
the cardiac output using Pulse Wave Transit Time (PWTT) which is obtained by
the pulse oximetry and ECG-signals from each cycle of the ECG and peripheral
pulse wave.
esCCOTM provides real-time, continuous and non-invasive cardiac output measurement alongside the familiar vital sign parameter of ECG and SpO₂.
By only entering patient information such as age, gender, height and weight,
and an initial NIBP measurement, esCCOTM determines a reference value for calibration and is ready for start the measurement.
Enhanced Hemodynamic Monitoring at No Extra Cost
Provided over the NIHON KOHDEN Patient Monitoring Series, esCCOTM represents a care enhancing and economic solution as no additional running costs
(accessories) related to the regular use of the monitor appear.
Figure 1: Pulse Wave Transit Time derived
from ECG and pulse oximetry signal
NIHON KOHDEN is contributing to the quality of care by providing completely non-invasive hemodynamic monitoring information in order to judge
tissue oxygenation better.
NIHON KOHDEN - Smart Cable™ Technology
A Cost-Effective Solution to Modular Monitoring
With NIHON KOHDEN Smart Cable Technology, you’ll get complete modular flexibility at a significantly reduced cost and without all of the inconvenience associated with traditional modular systems. Smart CableTM technology miniaturizes circuits found in traditional modules and embeds that
circuitry into the cable. When you plug a Smart CableTM into a MULTI connector, it automatically detects the type of parameter and starts measuring.
Smart Connector Technology is available for the following parameters:
Version 08/2012; Subject to
change without notice
Parameter
Current Products
PVM-2700
BSM-3000
Older Products
BSM-6000
BSM-9100
BSM-2300
BSM-4100
BSM-5100
FloTrac
–
–
–
–
–
BISx
–
with YJ-671P
with YJ-230P
–
with YJ-510P
Bisx remarks
–
–
via JA-60xP
(DAU) only
–
Dual SpO₂ (Second SpO₂)
–
–
over AUX
port only
–
–
over AUX
port only
–
–
IBP (Invasive Blood Pressure)
C.O. (Cardiac Output)
–
EtCO₂ (Capnography)
with PVM-2703
–
–
–
–
–
–
–
–
–
–
–
–
–
TEMP (Temperature)
RESP (Respiration)
FiO₂ (Fraction of inspired oxygen)
= Available
− = N/A
–
9
Highest Safety and Quality Standards
www.nihonkohden.net
Highest Safety and Quality Standards
Comprehensive quality assurance systems ensure that each of the more than 4,000 NIHON KOHDEN staff members
makes his/her contribution towards development, manufacture, marketing and customer services such that
maximum product quality is guaranteed.
NIHON KOHDEN is certified according to ISO 9001, ISO 13485 and ISO 14001.
NIHON KOHDEN designs and manufactures medical equipment in conformity with the standards of IEC 60601-1
(Medical Electrical Equipment: General Requirements for Safety).
NIHON KOHDEN products have earned a reputation for quality and long life. One reason is that all export products
and major components are manufactured in our own ISO 9001 and IEC 13485 certified factories.
In 1984, NIHON KOHDEN implemented a comprehensive companywide quality system, IQC – Integrated Quality
Control. Under this system, quality begins at the earliest stage of every product’s life. Our IQC applies to the entire
manufacturing process, from the planning stage through product development, design, parts procurement,
production, inspection, storage, sales, distribution and after-sales support. IQC also involves nearly every employee.
Our rigid test procedures are structured to exceed the provisions of the GMP, Good Manufacturing Practice, codes
enforced by the US Food and Drug Administration. NIHON KOHDEN also has 130 in-house quality control inspection
staff to ensure that standards are implemented and maintained in every department of the company.
IQC extends beyond production and into sales and support at each subsidiary. This staff is responsible for ongoing
contact with customers to determine their needs and making sure that these changing requirements are reflected
in new products. Service engineers are responsible for communicating any problem that may arise in the use of
NIHON KOHDEN products, and assuring the customers of NIHON KOHDEN’s commitment to their satisfaction.
In 1995, NIHON KOHDEN received ISO 9001 certification, the international standard for quality systems. In addition,
NIHON KOHDEN’s four manufacturing facilities in Japan are the first factories in the medical equipment industry to
be certified by the CSA, Canadian Standards Association, under their category certification system. Most products
sent to North America carry the CSA label.
Quality improvement is and always has been an ongoing process for NIHON KOHDEN.
Convince yourself of our expertise and the high quality of our products and services! Order directly!
10
www.nihonkohden.net
ECG Measurement
Highly accurate ec1 arrhythmia analysis
NIHON KOHDEN’s ec1 arrhythmia analysis provides superior elimination of false
alarms. ec1 has been evaluated with worlds standard arrhythmia databases as well as
NIHON KOHDEN’s ECG database, with a result of 80% reduction of false alarms.
Number of false alarms
3000
2500
V. Rhythm
Tachy
2000
VPC Run
1500
VT
Ext. Tachy
1000
VF
500
0
Without ec1
With ec1
11
www.nihonkohden.net
ECG Cables
3/6-Lead
ad
12-Lead
12
Patient Monitors › ECG Measurement
www.nihonkohden.net
ECG 3/6-Lead Cables
6-lead ECG measurement
V4 V5
Powerful ECG measurement
96% of an ischaemia change can be
detected by 6 electrodes (II, V4, V5)
Supply Code
Model
6124-039432
–
ST Change Detection Report
• Only with I lead symbol 33%
• Only with V5 lead symbol 75%
• II + V5 lead symbol 80%
• II + V5 + V4 lead symbol 96%
More accurate ischaemia detection
Description
Connection Cable Cover for DIN Type Electrodes for K922
For current products: all BSM/PVM/TEC-8300
Packing unit: 1 pcs
K120
NA-0003
Electrode Lead Tube for K911/K910A
For current products: TEC-55/77/8300/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 5 pcs
K910A
BR-913P
3-Lead ECG Electrode Cable, snap, cable length: 0.8 m
TEC-55/7700: for connection to defibrillators L153 is required
BSM/PVM/TEC-8300: for connection to monitors K922 is required
For current products: TEC-55/77/8300/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 1 pcs
K911
BR-903P
3-Lead ECG Electrode Cable, clip, cable length: 0.8 m
TEC-55/7700: for connection to defibrillators L153 is required
BSM/PVM/TEC-8300: for connection to monitors K922 is required
For current products: TEC-55/77/8300/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 1 pcs
K912
BR-906P
6-Lead ECG Electrode Cable, clip, cable length: 0.8 m, requires K922
For current products: all BSM/PVM/TEC-8300; ZM-920/930/940PG
Packing unit: 1 pcs
K915
BR-916P
6-Lead ECG Electrode Cable, snap, cable length: 0.8 m, requires K922
For current products: all BSM/PVM/TEC-8300; ZM-920/930/940PG
Packing unit: 1 pcs
K922
JC-906P
3/6-Lead ECG Connection Cable for K910A/K911/K912/K915
to patient monitors/defibrillator, cable length: 3.0 m
For current products: all BSM/PVM/TEC-8300
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
13
Patient Monitors › ECG Measurement
www.nihonkohden.net
ECG 10-Lead Cables
Supply Code Model
Description
K901
BJ-900P
10-Lead ECG Patient Cable (12 channel ECG), cable length: 3.8 m,
incl. patient electrode lead & connection cable
For TEC-8300 AC-831V is required!
For current products: BSM-3000/5100/6000/9100/TEC-8300
Packing unit: 1 pcs
K921
JC-900P
10-Lead ECG Patient Cable (12 channel ECG), cable length: 3.0 m, for
AY-900/910/920, for connection of pre-wired disposable electrodes
with DIN type connector
For current products: BSM-3000/5100/6000/9100/TEC-8300
Packing unit: 1 pcs
Leads, Cables and Cords
Note: Do not touch the socket pin. Do not wet the socket.
Cleaning the Leads, Cables and Cords
• Wipe with a soft cloth moistened with neutral soap, water or alcohol
and wipe with a dry cloth or gauze.
Disinfecting the Leads, Cables and Cords
• Wipe with a non-abrasive cloth moistened with any of the
disinfectants listed below. Use the recommended concentration.
Disposing of Leads, Cables and Cords
• For detailed information about disposal, contact your NIHON KOHDEN
representative.
Disinfectant
Concentration %
Chlorhexidine gluconate solution
0.5
Benzethonium chloride solution
0.2
Glutaraldeyde solution
2.0
Benzalkonium chloride
0.2
Alkyldiaminoethylgycine hydrochloride
0.5
14
www.nihonkohden.net
ECG Electrodes
NIHON KOHDEN VITRODE Disposable ECG Electrodes –
The result of over 30 years experience in disposable electrode manufacturing.
The ECG electrodes are the most important portions of the ECG/arrhythmia monitoring system. It is through these electrodes that the electrical signals are conducted from the patient and into the monitoring system. If the electrodes are
left in place for an extended period of time (over 48 hours), or they are reused once they are removed, they do not adhere to the patient’s skin and they cause “noisy’’ ECG signals because of the poor conduction. In addition, the patient’s
movement causes the electrodes to lose conducting capabilities intermittently, and this leads to a “wandering’’ ECG
waveform and muscle artifact. The standard monitoring practice is to change these electrodes at least every 48 hours.
Please contact us for individual offer based on your annual volume! Use the possibility of call orders!
15
Patient Monitors › ECG Measurement
www.nihonkohden.net
Standard Electrodes Placements
It is important to prepare the skin before attaching
the electrodes by cleaning it and removing chest
hair. After this please attach the lead wire to the
electrodes before placing them on the skin. This
avoids pain to the patient. Secure the lead wire to
the skin (stress loop) preventing moving of the lead
wire and therefore noise on the ECG signal.
Three electrodes
Six electrodes
Ten electrodes
ECG Electrodes for Adults
Supply Code
Model
Description
G203
L-150
ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, foam tape, solid gel,
general use
Packing unit: 5 x 30 pcs
G204
C-150
ECG Electrode Vitrode C, Ag/AgCl, adult, size: 47 mm dia, breathable cottony softcloth
with an elastic quality for tension, solid gel
Packing unit: 5 x 30 pcs
G207
L-150X
ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, radiolucent (X-ray, MRI, CT),
foam tape, solid gel
Packing unit: 5 x 30 pcs
G210D
F-150M
ECG Electrode Vitrode F, Ag/AgCl, adult, size M: 25 x 45 mm, cotton tape especially for
sensitive skin, adhesive gel
Packing unit: 3 x 50 pcs
G236
M-150
ECG Electrode Vitrode M, Ag/AgCl, child/adult, size: 40 mm dia, foam tape,
higbrid gel, for stress test
Packing unit: 5 x 30 pcs
G250
J-150
ECG Electrode Vitrode J, Ag/AgCl, adult, size: 40 mm dia, foam tape, solid gel, excellent
adhesion even on sweaty skin
Packing unit: 5 x 30 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
16
Patient Monitors › ECG Measurement
Supply Code
Model
G272A
V-09OM3 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm, cable length: 1.0 m,
radiolucent (X-ray, MRI, CT), hydrogel, foam & cotton tape, 3 pre-wired electrodes with
DIN connector
Packing unit: 30 x 3 pcs
Description
G272B
V-040M4 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm, cable length: 1.0 m,
radiolucent (X-ray, MRI, CT), hydrogel, foam & cotton tape, 4 pre-wired electrodes with
DIN conector for limb leads
Packing unit: 10 x 4 pcs
G272C
V-06OM6 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm, cable length: 1.0 m,
radiolucent (X-ray, MRI, CT), hydrogel, foam & cotton tape, 6 pre-wired electrodes with
DIN conector for chest leads
Packing unit: 10 x 6 pcs
G278A
V-09IO3
ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm, cable length: 1.5 m,
radiolucent (X-ray, MRI, CT), solid gel, foam tape, 3 pre-wired electrodes with DIN
connector
Packing unit: 30 x 3 pcs
ECG Electrodes for Children, Infants & Neonates
Supply Code
Model
Description
G210C
F-150S
ECG Electrode Vitrode F, Ag/AgCl, neonate/child, size S: 18 x 36 mm, cotton tape
especially for sensitive skin, adhesive gel
Packing unit: 3 x 50 pcs
G271A
V-120S3
ECG Electrode Vitrode V, Ag/AgCl, neonate/infant, w/o motif print, size: 20 mm dia,
cable length: 0.6 m, radiolucent (X-ray, MRI, CT), foam & cotton tape, 3 pre-wired
electrodes with DIN connector
Packing unit: 40 x 3 pcs
G300A
N-03IS3
ECG Electrode Vitrode N, Ag/AgCl, for NICU, size: 14 x 25 mm, cable length: 0.6 m,
radiolucent (X-ray, MRI, CT), foam tape, adhesive gel, 3 pre-wired electrodes with
DIN connector
Packing unit: 10 x 3 pcs
www.nihonkohden.net
17
www.nihonkohden.net
SpO₂ Measurement
A Pulse Oximeter is a non-invasive device used to percutaneously measure oxygen saturation
in the blood by use of a clip-on finger probe. Pulse oximeter works with the integration of a
probe placed onto patient’s fingertip or toe, obtains signals from the probe and the main
device calculates oxygen saturation in the body.
Oxygen saturation measured by pulse oximeter is SpO₂. “P” stands for “pulse”, and the measurement principle is based on beat-by-beat changes in blood volume. In general, arterial
oxygen saturation measured by spectroscopic analysis is called “SaO₂”, and oxygen saturation measured by pulse oximeter is called “SpO₂”.
The method for determination of arterial oxygen saturation, based on the photoelectric plethysmography, was conceptualised and implemented in 1972 by the Japanese bio-engineer
Takuo Aoyagi (NIHON KOHDEN Corporation). This idea came about while using an ear densitometer for recording dilution curves for dyes (pigments). The first commercial oximeter
“OLV-5100” was presented by NIHON KOHDEN back in 1975.
Dr. Aoyagi’s innovative technology, pulse oximetry, has rapidly spread worldwide and become essential in critical care. In
2002, Dr. Aoyagi was awarded the Medal of Honor in Japan, in recognition of his great contribution to clinical medicine.
The NIHON KOHDEN SpO₂ Sensors of the BluPRO® Series are at the cutting edge of this progressive technology.
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
18
Patient Monitors › SpO2 Measurement
www.nihonkohden.net
NIHON KOHDEN SpO₂ Cables
SpO₂ Adapter Cable for current patient monitors with rectangular connector
Supply Code
Model
Description
K931
JL-900P SpO2 Connection Cable, cable length: 2.5 m, rectangular connector
For current products: all BSM/PVM/TEC-8300
Packing unit: 1 pcs
SpO₂ Adapter Cable for older patient monitors with round connector
Supply Code
Model
Description
L301
JC-024P
Adapter Cable for SpO2 Measurement, cable length: 3.0 m, round connector
For old products: BSM-2000
Packing unit: 1 pcs
L302
JC-025P
Adapter Cable for SpO2 Measurement, cable length: 1.5 m, round connector
For old products: BSM-2000
Packing unit: 1 pcs
SpO₂ Adapter Cable for OLV-2700/3100 & OPV-1500
Supply Code
Model
Description
L311
JL-302T
SpO2 Connection Cable, cable length: 2.5 m
For current products: OLV-2700/3100; OPV-1500
Packing unit: 1 pcs
Dual SpO₂ Adapter Cable
Supply Code
Model
Description
Y094A
JL-500P2 Dual SpO2 Cable for Input Boxes AY-661/663P, cable length: 2.5 m
For current products: BSM-6000/9100
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
19
www.nihonkohden.net
NIHON KOHDEN SpO₂ Probes
BluPRO® SpO₂ Probes – A Unique Sensing Technology
Reliability and high quality of our probes provide a continuous accurate and safe monitoring with highest patient
comfort. The comfortable, sure fitting and lightweight characteristic reduces the effect of hand movement for
highly reliable SpO2 measurement.
This ensures patient safety, reduces the costs of care and increases therefore clinical efficiency and cost
effectiveness. NIHON KOHDEN BluPRO® SpO2 Probes are comfortable, durable, accurate and needs-oriented.
Note that accurate and safe measurement is assured only when you use probes, connection cords and parts manufactured by NIHON KOHDEN. Some probes in the market may advertise as „compatible with NIHON KOHDEN
probes.“ We strongly recommend you to avoid these probes as a correct measurement cannot be guaranteed on
NIHON KOHDEN devices. NIHON KOHDEN is not responsible for problems caused by using other manufacturer’s probes.
Please contact us for an individual offer based on your annual volume! Use the possibility of call orders!
Disposable
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Patient Monitors › SpO2 Measurement
www.nihonkohden.net
SpO₂ Probes
ing
Child
Adult
)
(m
Disposable
Infant
it
un
h
gt
l en
l)
de
Mo
(
de
ck
Pa
Co
ble
Ca
ly
pp
Su
Low birth Neonate
weight
1000 g
P203A (TL-271T)
0.8
P203E (TL-271T3)
1.6
P204A (TL-271T)
0.8
P204E (TL-271T3)
1.6
P203B (TL-272T)
0.8
P203F (TL-272T3)
1.6
P204B (TL-272T)
0.8
P204F (TL-272T3)
1.6
P203C (TL-273T)
0.8
P203G (TL-273T3)
1.6
P204C (TL-273T)
0.8
P204G (TL-273T3)
1.6
P203D (TL-274T)
0.8
P203H (TL-274T3)
1.6
P204D (TL-274T)
0.8
P204H (TL-274T3)
1.6
P228A (TL-051S)
0.8
P228B (TL-052S)
1.6
P229A (TL-061S)
0.8
P229B (TL-062S)
1.6
P205A (TL-260T)
1.6
P260A (Tape S)
1.6
P225H (TL-201T1)
0.6
1.6
P311C (TL-631T3)
1.6
P310C (TL-630T3)
1.6
10 kg
20 kg
30 kg
40 kg
50 kg
24
5
24
5
24
5
5
5
5
1
P225G (TL-220T)
3 kg
5
P256
P225F (TL-201T)
2 kg
24
24
P260B (Tape L)
Reusable
20
Tape S
Tape L
Tape S
With P205A ear clip
21
Patient Monitors › SpO2 Measurement
www.nihonkohden.net
Reusable SpO₂ Probes
Reusable, but always clean – NIHON KOHDEN washable probes.
The reusable probes of the BluPRO® series are durable and washable,
so you can clean them under running water or even immerse them in a
soapy alkaline or disinfectant solution (glutaraldehyde solution 2.0 %
or hydrochloric alkyl diaminoethylene glycine 0.5 %)!
P225F / P225H
P225G
Durable, washable, needs-oriented!
P310C / P311C
Facts
NIHON KOHDEN reusable SpO2 finger-clips probes have paraellel mounted upper and lower sensor shells, thus, providing on the one hand, exact alignment of the optical sensor components vis-à-vis one another and on the other hand, markedly enhanced comfort during long-term attachment. In
addition, flexible lateral flaps shield the measuring signals from the external light, thus resulting to minimize the interference by additional artificial
light sources! Bright LEDs provide more accurate measurement even for thicker fingers or dark skin tones. The finger-clip reusable probe is the most
popular type of SpO2 probes. Instead of the typical hinge near the finger tip, P225F/P225H have a unique sure fitting and comfortable mechanism using
two sliding pieces for the front and back of the finger with two rubber flaps along both sides of the finger. When you press the button, the two halves
of the probe slide directly open, parallel to each other. No additional fixation tape is needed. For a stable and comfortable measurement P225F/P225H,
always keep the light emitters and detector aligned. NIHON KOHDEN provides unique reusable SpO2 probes.
Supply Code Model
Description
P225F
TL-201T
SpO₂ BluPRO® Finger-Clip Probe, child/adult (> 20 kg) finger, cable length: 1.6 m,
reusable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 1 pcs
P225H
TL-201T1
SpO2 BluPRO® Finger-Clip Probe, child/adult (> 20 kg) finger, cable length: 0.6 m,
reusable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 1 pcs
Facts
The multi-site probe P225G can be used for neonatal feet as well as adult fingers as its curved contact surface is designed to fits on different attachment
sites. The light emitter and detector are separate which allows especially an accurate alignment of the LED on the infant/neonatal instep. A unique sliding
adjuster gives the best fit on the attachment site secured by taping.
Supply Code Model
Description
P225G
SpO2 BluPRO® Multi-Site Probe, neonate (< 3 kg) instep,
child/adult ( > 3 kg) finger/toe, cable length: 1.6 m, reusable
For current products: all BSM/PVM/TEC/EEG;
ZS-930/530/940PG; ZM-930/940PG
Packing unit: 1 pcs
TL-220T
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
22
Patient Monitors › SpO2 Measurement
www.nihonkohden.net
Facts
Our special designed finger-tip probes, P310C and P311C, fit immediately on the finger and are perfect for long-term measurement. A less covered finger
area and cushioned materials lead to decrease pressure to the attachment site. The 3D molding attachment ensures a comfortable fit.
In combination with the soft and lightweight design the patient stress or discomfort is reduced and the probes can be remained up to 8 hours to one attachment site. A stable measurement is assured by gentle fixation tapes P263 or P267 that avoid the falling off of the probes and reduce artefacts from cable
movement.
Reusable but with the comfort of a disposable probe, P310C and P311C are also applicable for sleep studies, for patients that are often bending their fingers
or obese patients.
Supply Code Model
Description
P310C
TL-630T3
SpO2 BluPRO® Finger-Tip Probe L, child/adult (> 50 kg) finger, cable length: 1.6 m,
long-term use, reusable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 1 pcs
P311C
TL-631T3
SpO2 BluPRO® Finger-Tip Probe M, child/adult (> 20 kg) finger, cable length: 1.6 m,
long-term use, reusable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 1 pcs
P263
P267
Disposable Probe Cable Fixing Tape for P310C/P311C, size: 15 x 130 mm
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 3 x 30 pcs
YS-093P2
Reusable Probe Fastener Tape for P310C/P311C,
size: 15 x 140 mm
For current products: all BSM/PVM/TEC/EEG;
ZS-930/530/940PG; ZM-930/940PG
Packing unit: 30 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
23
Patient Monitors › SpO2 Measurement
www.nihonkohden.net
Facts
The multi-site probe P205A can be used for SpO2 measurement for children and adults as well as for prematures in combination with special attachment
tapes. For measuring SpO2 on children or adults with P205A, the ear clip P256 is required.
The ear clip is designed to hold the light emitters and detector of the probe P205A and be clipped onto the earlobe of the patient. P256 is intended for
use when SpO2 measurement on a finger or toe is difficult and the patient is at rest with little body movement. The P205A can be inserted in the special
designed slots on the ear clip without sticking out of the clip edge. A secure fit is provided by additional cable slots, silicone surfaces for the earlobe and
supplementary fixation of the cable with tape near the earlobe. The multi-site probe is intended for single-patient use and needs to be replaced after each
patient measurement. The ear clip can be reused. Clean it after every use with a soft cloth moistened with 70% ethanol solution. Dry the clip thoroughly
after cleaning.
Supply Code Model
Description
P205A
TL-260T
SpO2 Multi-Site Probe, cable length: 2.0 m, neonate (< 3kg ) instep, child/adult
(> 3 kg) finger/toe, fixed with P260A/B or for P256, single-patient use
For current products: all BSM/PVM/TEC/EEG
Packing unit: 5 pcs
P256
6143-012434 SpO2 Ear-Clip for P205A , child/adult (> 30 kg)
For current products: all BSM/PVM
Packing unit: 1 pcs
Disposable SpO₂ Probes
NIHON KOHDEN disposable probes, from neonate to adult sizes, place special emphasis on the exact positioning of the LEDs and
detector. For this reason the two optical components are designed separately and can thus be brought into precise alignment with
each other by the user. All probes have breathable material and can be remained up to 8 hours on one attachment site. Paediatric
probes have a cute cartoon character printed on the tape to reassure children.
Self-adhesive, soft and thin tape provides a secure fit. The special design allows an easy application to the attachment site. To get
the most comfortable fit, please bend the probe before attaching, do not strongly pull the attachment tape when attaching and do
not push the tip of the finger with the attachment tape.
Disposable SpO₂ Probes 24 pcs/box – cable length: 0.8 m
Supply Code Model
Description
P203A
TL-271T
SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
P203B
TL-272T
SpO2 BluPRO® Probe, child (10 – 50 kg) finger/toe, cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
24
Patient Monitors › SpO2 Measurement
Supply Code Model
Description
P203C
TL-273T
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
P203D
TL-274T
SpO2 BluPRO® Probe, infant (3 – 20 kg) finger/toe, cable length: 0.8 m,
disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
Disposable SpO₂ Probes 24 pcs/box - cable length: 1.6 m
Supply Code Model
Description
P203E
TL-271T3
SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
P203F
TL-272T3
SpO2 BluPRO® Probe, child ( 10 – 50 kg) finger/toe, cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
P203G
TL-273T3
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe, cable length:
1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
P203H
TL-274T3
SpO2 BluPRO® Probe, infant (3 – 20 kg) finger/toe, cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
Disposable SpO₂ Probes 5 pcs/box - cable length: 0.8 m
Supply Code Model
Description
P204A
SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
TL-271T
www.nihonkohden.net
25
Patient Monitors › SpO2 Measurement
Supply Code Model
Description
P204B
TL-272T
SpO2 BluPRO® Probe, child (10 – 50 kg) finger/toe, cable length: 0.8 m,
disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P204C
TL-273T
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P204D
TL-274T
SpO2 BluPRO® Probe, infant ( 3 –20 kg) finger/toe, cable length: 0.8 m
disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
www.nihonkohden.net
Facts
Absolutely cost-effective, the series P228 and P229 are intended for long-term measurement on a single patient. The probes do not need to be replaced
with a new one before 96 hours by changing the attachment site every 8 hours. So your running costs can be reduced!
The light emitter and detector are covered by sponge and the entire attachment site has a flat surface. This reduces the risk of skin burn and irritation.
Since the probe itself is not self-adhesive, you can easily remove and attach the probe to change the attached finger. For fixation, wrap the probe around
the finger with attachment tape P259.
Supply Code Model
Description
P228A
TL-051S
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 50 kg) finger,
cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P229A
TL-061S
SpO2 BluPRO® Probe, infant/child (3 – 15 kg) toe, child (15 – 50 kg) finger,
cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P259
COTTONY Tape for fixing disposable SpO2 Probes, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940OPG; ZM-930/940PG
Packing unit: 20 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
26
Patient Monitors › SpO2 Measurement
www.nihonkohden.net
Disposable SpO₂ Probes 5 pcs/box - cable length: 1.6 m
Supply Code Model
Description
P204E
TL-271T3
SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P204F
TL-272T3
SpO2 BluPRO® Probe, child (10 – 50 kg) finger/toe, cable length: 1.6 m,
disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P204G
TL-273T3
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P204H
TL-274T3
SpO2 BluPRO® Probe, infant (3 – 20 kg) finger/toe, cable length: 1.6 m,
disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
Facts
Absolutely cost-effective, the series P228 and P229 are intended for long-term measurement on a single patient. The probes do not need to be replaced
with a new one before 96 hours by changing the attachment site every 8 hours. So your running costs can be reduced! The light emitter and detector
are covered by sponge and the entire attachment site has a flat surface. This reduces the risk of skin burn and irritation. Since the probe itself is not
self-adhesive, you can easily remove and attach the probe to change the attached finger. For fixation, wrap the probe around the finger with attachment
tape P259.
Supply Code Model
Description
P228B
TL-052S
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 50 kg) finger, cable length: 1.6
m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P229B
TL-062S
SpO2 BluPRO® Probe, infant/child (3 – 15 kg) toe, child (15 – 50 kg) finger,
cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P259
COTTONY Tape for fixing disposable SpO2 Probes, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 20 pcs
Patient Monitors › SpO2 Measurement
27
www.nihonkohden.net
Disposable Multi-Site SpO₂ Probes 5 pcs/box - cable length: 2.0 m
Facts
The probe P205A is specially designed for extremely sensitive skin. It uses soft and breathable sponge for the attachment tape. The attachment tape
and sensor parts are separate. You can select from two sizes of attachment tape: P260A or P260B. When using the probes without those tapes for
prematures, SpO2 measurement may be incorrect and the skin at the attachment site may be irritated.
The attachment tape consists of two parts: adhesive and non-adhesive part. To get best fit, place the tape at the required attachment site. Wrap
the sponge attachment tape (non-adhesive part) around the attachment site. Confirm that the light emitters and detector face to each other before
removing backing paper of the adhesive part. Then continue wrapping to fasten the probe. Replace the sponge attachment tapes every 24 hours.
Supply Code Model
Description
P205A
SpO2 Multi-Site Probe, cable length: 2.0 m, neonate (< 3 kg) instep, child/adult (> 3 kg)
finger/toe, fixed with P260A/B or for P256, single-patient use
For current products: all BSM/PVM
Packing unit: 5 pcs
TL-260T
P260A
Sponge Attachment Tape Type S for P205A, premature (< 1 kg) instep, neonate/infant
(> 3 kg) finger/toe, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
P260B
Sponge Attachment Tape Type L for P205A, neonate (> 3 kg) instep, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
Handling of the probe affects measurement accuracy and patient safety
For the proper placement of the probe on the finger, it is advisable that the light emitters and detector are placed just opposite to each
other. When using a clip-finger probe, it is necessary to ensure that the probe covers the finger properly, otherwise some portion of the
light never passes through the body tissues and may reach the light-receiving part directly, leading to incorrect measurement results.
The more distant the light-emitters and detector gets, the weaker the transmitted light intensity becomes. Additionally, a thinner body part
tends to have small amount of blood, wich makes it difficult to extract the arterial blood signal component. The most suitable thickness
of the probe site is about 10 mm.
Too loose probes may interfere with alignment of LEDs and detector, come off easily by body movement, cause larger motion artifacts or
be effected by venous pulse.
Too tight probes may cause venous pulsation, cause skin injuries such as burn and necrosis or unstable measurement because of a lower
pulsatile signal.
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
28
www.nihonkohden.net
Nellcor & Masimo SpO₂ Probes
Please order Nellcor & Masimo SpO2 Probes from your local Nellcor & Masimo supplier!
Only initial sales packages together with patient monitors and/or input units can be provided by NIHON KOHDEN!
29
Patient Monitors › Nellcor & Masimo SpO2 Measurement
www.nihonkohden.net
Cables for Nellcor SpO₂ Probes
Supply Code
Model
Description
K935
JL-650P
Nellcor SpO2 Connection Cable, for modules AY-651/653P, cable length: 3.0 m
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
Cables for Masimo SpO₂ Probes
Supply Code
Model
Description
K936
JL-630P
Masimo Connection Cable modules for LNOP SpO2 Probes, for modules AY-631/633P,
cable length: 6.0 m
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
K937
JL-631P
Masimo Connection Cable for LNCS SpO2 Probes, for modules AY-631/633P,
cable length: 3.0 m
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
30
www.nihonkohden.net
NIBP Measurement (Non-Invasive Blood Pressure)
Blood pressure (BP) is the pressure exerted by circulating blood against the artery walls. During each heartbeat, the blood
pressure varies between a maximum (systolic) and a minimum (diastolic) pressure. The variation indicates the condition
of the pumping function of the heart as an important vital sign.
A non-invasive indirect method to measure the blood pressure is the oscillometric blood pressure measurement. This method is using an inflated blood pressure cuff which is applied to the patient’s arm or thigh. The blood pressure is detected
by partial occlusion of the artery by the cuff. The so called Korotkoff sound is generated by the distension of the arterial
wall with each cardiac impulse. Systolic and diastolic blood pressures are determined by an algorithmic interpretation of
the device based on the mean arterial pressure and changing amplitude of the Korotkoff sounds.
For a proper non-invasive measurement it is important to use the correct cuff size due to the fact that a cuff too small will
lead to faulty high pressure, while a large cuft can lead to wrong low pressure readings.
Please contact us for an individual offer based on your annual volume! Use the possibility of call orders!
31
Patient Monitors › NIBP Measurement
www.nihonkohden.net
NIBP Air Hoses
Supply Code
Model
Description
S901
YN-900P
Child/Adult NIBP Air-Hose, cable length: 1.5 m
For current products: all BSM/PVM/TEC-77/8300
Packing unit: 1 pcs
S902
YN-901P
Child/Adult NIBP Air-Hose, cable length: 3.5 m
For current products: all BSM/PVM/TEC-77/8300
Packing unit: 1 pcs
S903
YN-990P
NIBP Air-Hose Extension Cable, cable length: 1.5 m
For current products: all BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S904
YN-920P
Neonate NIBP Air-Hose, cable length: 1.5 m
For current products: all BSM/PVM
Packing unit: 1 pcs
S905
YN-921P
Neonate NIBP Air-Hose, cable length: 3.5 m
For current products: all BSM/PVM
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
32
Patient Monitors › NIBP Measurement
www.nihonkohden.net
Reusable Standard NIBP Cuffs
Supply Code Model
Description
S943A
YP-960T
Infant NIBP Cuff, width: 5 cm, arm-circumference: 8 to 13 cm, latex-free, reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S943B
YP-961T
Child NIBP Cuff, width: 7 cm, arm-circumference: 12 to 18 cm, latex-free, reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S943C
YP-962T
Child NIBP Cuff, width: 10 cm, arm-circumference: 15 to 23 cm, latex-free, reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S944B
YP-963T
Adult NIBP Cuff, width: 13 cm, arm-circumference: 21 to 30 cm, latex-free, reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S944C
YP-964T
Adult NIBP Cuff, width: 15 cm, arm-circumference: 26 to 36 cm, latex-free, reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S944D
YP-965T
Adult NIBP Cuff, thigh, width: 19 cm, thigh-circumference: 33 to 45 cm, latex-free,
reusable
For current products: BSM/PVM/TEC-77/8300
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
33
Patient Monitors › NIBP Measurement
www.nihonkohden.net
Reusable YAWARA NIBP Cuffs
Facts
NIHON KOHDEN YAWARA-CUFF means soft and strong. The name YAWARA is based on the Japanese words YAWARAkai = Soft (in Japanese),
YAWARA Judo (in Japanese) and Judo means Strong.
The softness of the cuff is realized in the soft and smooth polyester with a buffer sheet over the skin contact area reducing the risk of wrinkling the
patient’s skin and the risk of internal bleeding. The buffer sheet also evenly distributes the air pressure to prevent too much pressure on one point.
The strongness is realized both in the nylon cable in the air tube preventing incidents caused by tube kinking and the durable bladder material
(polyurethane).
In addition to this the YAWARA-CUFF is characterized by easy handling. A wide opening lets you easily remove and insert the bladder for cleaning. The cloth is
water-resistant, so you can wipe it without any problem. The watertight connector cap prevents fluid from getting into the air tube while cleaning and is provided with each cuff. An outside printed cuff scale behind the arm helps you quickly check if the cuff has the right size for the patient. The upper arm should be
between the minimum and maximum scale.
Supply Code Model
Description
S949A
YP-702T
Child NIBP YAWARA Cuff, width: 10 cm, arm-circumference: 15 to 23 cm, latex-free,
reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S949B
YP-703T
Adult NIBP YAWARA Cuff, width: 13 cm, arm-circumference: 21 to 30 cm, latex-free,
reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
34
Patient Monitors › NIBP Measurement
www.nihonkohden.net
Disposable NIBP Cuffs
Disposable NIBP Cuffs for Neonates
Supply Code
Description
NKD-S948A
Neonate NIBP Cuff, width: 1 cm, arm-circumference: 3 to 6 cm, color: orange, latex-free,
disposable
For current products: all BSM/PVM
Packing unit: 10 pcs
NKD-S948B
Neonate NIBP Cuff, width: 2 cm, arm-circumference: 4 to 8 cm, color: light blue,
latex-free, disposable
For current products: all BSM/PVM
Packing unit: 10 pcs
NKD-S948C
Neonate NIBP Cuff, width: 3 cm, arm-circumference: 6 to 11 cm, color: green, latex-free,
disposable
For current products: all BSM/PVM
Packing unit: 10 pcs
NKD-S948D
Neonate NIBP Cuff, width: 4 cm, arm-circumference: 7 to 14 cm, color: dark blue,
latex-free, disposable
For current products: all BSM/PVM
Packing unit: 10 pcs
NKD-S948E
Neonate NIBP Cuff, width: 5 cm, arm-circumference: 8 to 15 cm, color: red, latex-free,
disposable
For current products: all BSM/PVM
Packing unit: 10 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
35
Patient Monitors › NIBP Measurement
www.nihonkohden.net
Disposable NIBP Cuffs for Infants & Children
Supply Code
Description
NKD-S947A
Infant NIBP Cuff, width: 6 cm, arm-circumference: 8 to 14 cm, color: blue, latex-free,
disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947B
Child NIBP Cuff, width: 8 cm, arm-circumference: 13 to 20 cm, color: green, latex-free,
disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
Disposable NIBP Cuffs for Adults
Supply Code
Description
NKD-S947C
Small Adult NIBP Cuff, width: 10 cm, arm-circumference: 18 to 26 cm, color: orange,
latex-free, disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947D
Adult NIBP Cuff, width: 14 cm, arm-circumference: 26 to 35 cm, color: blue, latex-free,
disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947E
Adult Long NIBP Cuff, width: 15 cm, arm-circumference: 29 to 38 cm, color: red,
latex-free, disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947F
Adult Large NIBP Cuff, width: 7 cm, arm-circumference: 32 to 42 cm, color:green,
latex-free, disposable
For current products: all BSM/PVM, TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947G
Large Adult Long NIBP Cuff, width: 18 cm, arm-circumference: 35 to 44 cm,
color: orange, latex-free, disposable
For current products: all BSM/PVM, TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947H
Adult Thigh NIBP Cuff, width: 20 cm, thigh-circumference: 42 to 50 cm, color: blue,
latex-free, disposable
For current products: all BSM/PVM, TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
36
Temperature Measurement
Please contact us for an individual offer based on your annual volume! Use the possibility of call orders!
www.nihonkohden.net
37
Patient Monitors › Temperature Measurement
www.nihonkohden.net
Standard Temperature Measurement
Supply Code
Model
Description
NKD-P240A
YSI-401
Esophagus/Rectum Thermistor Probe, adult, 6.3 mm jack connector, size: 4 mm dia,
length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-P241A
YSI-402
Esophagus/Rectum Thermistor Probe, neonate/child, 6.3 mm jack connector,
size: 3.3 mm dia, length: 3.5 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-P242B
YSI-409B Body Surface Temperature Probe, 6.3 mm jack connector, disk size: 9.5 mm dia,
cable length: 3.5 m, reusable
Use NKD-Temphearts4009/4012 to fix this probe!
For current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300
Packing unit: 1 pcs
NKD-P249
Temperature Probe Cover for NKD-P240A/241A
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 10 pcs
NKD-TEMPHEARTS4009
Tempheart Adhesive Pads, to fix temperature probes, size: 1.5 cm dia
For current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300
Packing unit: 100 pcs
NKD-TEMPHEARTS4012
Mini-Tempheart Adhesive Pads, to fix temperature probes, size: 1.13 cm dia
For current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300
Packing unit: 100 pcs
Measurement of 2 Additional Temperatures
Supply Code
Model
Description
K961
JT-900P
Temperature Connection Cable for NKD-P241/242x, cable length: 0.3 m
For current products: BSM-5100/6000/9100/ TEC-8300
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
38
www.nihonkohden.net
CO₂ Measurement (Capnography)
Reasons to measure EtCO₂ (the level of carbon dioxide in the air exhaled from the body - normal value is about 38 mmHg):
Capnography helps to detect life-threatening problems in Airway, Breathing (ventilator or anesthesia circuit problems), Circulation and the Metabolism.
Capnography is a fast and reliable help to determinate respiratory difficulties, wrong connections of airway adapters, leaks in the
ventilator circuit due to its placement in the respiratory circuit. An early detection by capnography might help to avoid inadequate
oxygen supply of the body.
39
Patient Monitors › CO2 Measurement (Capnography)
www.nihonkohden.net
CO₂ Measurement (Capnography)
The necessity of monitoring EtCO₂ is recognized
by various health care associations guidelines:
capnometer
Mainstream Method
Canadian Anesthesia Society (CAS)
Guidelines for Sedation – January, 2012
In a mainstream system, the
Anesthesia Patient Safety Foundation (APSF)
Monitoring with Use of Post-op Opioids – August, 2011
the patient’s breathing circuit.
sensor is located directly in
Real time measurement values.
American Society for Anesthesiologists (ASA)
Standards for Basic Anesthetic Monitoring – July, 2011
CO₂ Sensor
Association of Anaesthetists of Great Britain & Ireland (AAGBI)
The use of capnography outside the operating theatre – May, 2011
American Association of Respiratory Care (AARC)
CPG for Capnography/Capnometry During Mechanical
Ventilation – April, 2011
capnometer
Sidestream Method
CO₂ Sensor
In a sidestream system, a gas
British Royal College of Anesthetists
Airway Recommendation (NAP4) – March, 2011
sample is removed from the
European Resuscitation Council (ERC)
Guidelines for Resuscitation – November, 2010
to a distant sensor.
patient’s airway and delivered
Measurement values delayed.
Suck in
American Heart Association (AHA)
Sampling tube
Resuscitation Guideline – November, 2010
CO₂ Selection Guide
Start
Yes
No
Is CO₂ the only gas to measure?
Multi gas unit
GF-110/120PA
GF-210/220R
No
Is the patient a neonate?
Yes
Sidestream measurement
Yes
Is the patient intubated?
Mainstream measurement
No
Is the patient intubated?
AG-400RA/K CO₂ unit
Filterline
Multi-gas measurement
No
Yes
Capnoline
CO₂ sensor kit P907 (TG-920P)
Is a humidifier or nebulizer used?
Both intubated & non-intubated
No
Yes
With nebulizer
CO₂ sensor kit P909 (TG-970P)
Intubated
Non-intubated
R805 (YG-121T) Airway adapter adult (>7 kg)
R804 (YG-111T) Airway
adapter (>7 kg)
V921 (YG-120T) Nasal adapter
(> 10 kg)
R806 (YG-213T) Airway adapter neonate/infant
(2 to 7 kg)
CO₂ sensor kit P903 (TG-900P)
R801 (YG-101T) Airway adapter adult, (>10 kg)
V922 (YG-121T) Nasal/Oral
adapter (>10 kg)
V923 (YG-122T) Nasal adapter
with O₂ supply tube adapter
(>10 kg)
NKD-02-Cap Oxygen cannula
40
Patient Monitors › CO2 Measurement (Capnography)
www.nihonkohden.net
CO₂ Mainstream
Application Fields of Airway Adapters
for Intubated Patients
Application Fields of Nasal Adapters
for Non-Intubated Patients
OR
Checking if endotracheal intubation is correctly done
and checking situations of low air ventilation, shock
(sudden drop of blood pressure), and pulmonary
embolism, checking respiration circuit during
anesthesia.
ICU/Recovery room/PACU/Transport
Where anesthetic drug effects may linger and ventilation
may be insufficient.
ER
Checking airway control, heart massages, checking if
endotracheal intubation is correctly done.
ICU/Ward
Preventing ventilator accidents/leaks.
ER/Cardiac cath lab/GI Endoscopy/Pain management
Where sedation and supplemental oxygen are frequently
administrated.
OR/Abdominal surgery/Obstetric/Orthopedic/Eye surgery/
Plastic surgery/Dental surgery
During surgery without intubation, such as under spinal/
epidural/local anesthesia.
CO₂ Mainstream
Intubated expired CO₂
Supply Code Model
Description
P903
TG-900P
CO2 Sensor Kit for Intubated Patients, semi-quantitative measurement,
incl. P922A/K981, expiratory CO2, cable length: 3.0 m
For Aiway Adapters: R801
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs
P922A
TG-101T
CO2 Sensor for Expiratory CO2 for Intubated Patients, part of CO2 Sensor Kit P903,
cable length: 1.0 m
Requires Adapter Cable: K981
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs
K981
JG-900P
CO2 Adapter Cable for P922A/P903, cable length: 2.0 m
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs
R801
YG-101T
Airway Adapter for P903/P906/P922A, intubated, semi-quantitative method,
child/adult (>10 kg), dead space: 5 mL
for P903: all BSM/PVM-2703/OLG-2800/TEC-8300
for P906: TEC-5500/7700
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 50 pcs
41
Patient Monitors › CO2 Measurement (Capnography)
www.nihonkohden.net
Intubated expired and inspired CO₂ „Opening a New Era in Capnography“
Facts
NIHON KOHDEN CO2 Sensor Sensation - P909 World‘s smallest and lightest mainstream EtCO2 Sensor (quantitative method) with only 4 g (±2 g).
This avoids tube pressures and increases patient comfort. Especially for this reason as well as the dead space of approximately 1 mL it is perfectly suited to
the most sensible intubated patients - neonates in critical care. Besides this P909 can be also applied to children and adults. Easy and simple handling is
guaranteed by its waterproofness (IPX7 standard) and our Smart CableTM Technology so that no additional module is needed. Just plug in and start a continuous measurement after only 10 seconds warm-up time. Those features make the P909 an unbeatable help for daily work routine in OR, ER, ICU or Ward.
Supply Code Model
Description
P909
TG-970P
CO2 Sensor Kit for Intubated Patients, quantitative
measurement, incl. P924/K987,
size: 8 x 13 x 35 mm, cable length: 3.5 m
For Airway Adapters: R805/R806
For current products: all BSM/PVM-2703/
OLG-2800/TEC-8300
Packing unit: 1 pcs
P924
TG-221T
CO2 Sensor for Intubated Patients, part of CO2 Sensor Kit P909, cable length: 3.0 m
Requires Adapter Cable: K987
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs
K987
JG-970P
CO2 Adapter Cable for P909/P924, cable length: 0.5 m
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs
R805
YG-211T
Airway Adapter for P909, intubated, quantitative method,
adult (>7 kg), dead space: 4 mL
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 30 pcs
R806
YG-213T
Airway Adapter for P909, intubated, quantitative method,
neonate/child (2-7 kg), dead space: 1 mL
For current products: all BSM/PVM-2703/OLG-2800
Packing unit: 30 pcs
V910
YG-270P
Connector for Airway Adapter R806, infant/child (4-7 kg), to use with P909
The V910 airway adapter has an inner cylinder to reduce dead space. When this airway
adapter and P909 CO2 sensor are used together with a ventilator which has a flow sensor that is close to the patient’s mouth, there is some interference between the flow
sensor and airway adapter because both the flow sensor and airway adapter have an
inner cylinder. To eliminate this interference, use a V910 connector between the airway
adapter and flow sensor.
For current products: all BSM/PVM-2703
Packing unit: 30 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
42
Patient Monitors › CO2 Measurement (Capnography)
www.nihonkohden.net
Intubated and non-intubated expired CO₂
„Opening a New Era in Capnography“
Facts
NIHON KOHDEN capONE... when every breath counts!
World’s first wearable, mainstream CO2 sensor P907 (semi-quantitative method) for intubated and non-intubated patients which is applicable for
children and adults.
Unique oral-nasal airway adapters catch oral as well as nasal expired CO2 – this increases accuracy. The capOne is not only small but has also a
mini-weight of only 4 g. This avoids tube pressures and increases patient comfort. Easy and simple handling is guaranteed by our Smart CableTM Technology so
that no additional module is needed, just plug in and start measuring after only 5 seconds. A continuous, stable and accurate measurement is ensured
due to no lag time and no need to change tubes because of occlusions. Its waterproofness and outstanding shock resistance are an unbeatable advantage in daily work routine.
Those features make the capOne P907 an excellent measurement tool in OR, ICU, Recovery Room, PACU, Transport, ER, Cardiac Catheter Laboratory, GI
Endoscopy, Pain Management, Abdominal Operation, Obstetric/Orthopedic/Eye Surgery, Plastic or Dental Surgery.
Supply Code Model
Description
P907
TG-920P
CapONE CO2 Sensor Kit for Intubated/Non-Intubated
Patients, semi-quantitative measurement,
incl. P923/K984, size: 11 x 11 x 40 mm, cable length: 3.5 m
For Airway Adapters:
Intubated patients: R804
Non-intubated patients: V921/V922/V923
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs
P923
TG-121T
CapONE CO2 Sensor for Intubated/Non-Intubated Patients, part of CO2 Sensor Kit
P907/P908, cable length: 1.5 m
Requires Adapter Cable: K984
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs
K984
JG-920P
CapONE CO2 Adapter Cable for P923/P907, cable length: 2.0 m
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 1 pcs
R804
YG-111T
Airway Adapter for P907/P908/P923, intubated, child/adult (>7 kg), dead space: 4 mL
for P907: all BSM/PVM-2703/TEC-8300/OLG-2800
for P908: TEC-5500/7700
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 30 pcs
V921
YG-120T
CO2 Nasal Adapter for Nasal Breathing, non-intubated, child/adult (>10kg)
for P907: all BSM/PVM-2703/TEC-8300/OLG-2800
for P908: TEC-5500/7700; EEG-1200/9100/9200
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/EEG
Packing unit: 30 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
43
Patient Monitors › CO2 Measurement (Capnography)
V922
YG-121T
CO2 Nasal Adapter for Nasal/Oral Breathing, non-intubated, child/adult (>10 kg)
for P907: all BSM/PVM-2703/TEC-8300/OLG-2800
for P908: TEC-5500/7700, EEG-1200/9100/9200
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/EEG
Packing unit: 30 pcs
V923
YG-122T
CO2 Nasal Adapter for Nasal/Oral Breathing with Oxygen Cannula Holder,
non-intubated, child/adult (>10kg)
for P907: all BSM/PVM-2703/TEC-8300/OLG-2800
for P908: TEC-5500/7700, EEG-1200/9100/9200
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/EEG
Packing unit: 30 pcs
NKD-O2-CAP
Oxygen Cannula for Nasal Adapter V923 for P907/P908
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/EEG
Packing unit: 50 pcs
NKD-CO2GAS
Calibration Gas for CO2-Measurement
Please be aware that the calibration gas cannot be sent by plane! So, when such
calibration gas is needed, you should be aware that the delivery might take some
time. Please store the gas below 50°C!
For current products: all BSM
Packing unit: 1 pcs
NKD-VENTIL3
CO2 Gas Valve
For current products: all BSM
Packing unit: 1 pcs
Supply Code Model
Description
R802
YG-201T
Airway Adapter for P905/P921, intubated, quantitative measurement, adult (>10 kg),
dead space: 5 mL
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 30 pcs
R803
YG-202T
Airway Adapter for P905/P921, intubated, quantitative measurement, neonate/child
(3-10 kg), dead space: 2 mL
For current products: all BSM/PVM-2703/OLG-2800/TEC-8300
Packing unit: 30 pcs
www.nihonkohden.net
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
44
Patient Monitors › CO2 Measurement (Capnography)
www.nihonkohden.net
CO₂ Sidestream (Covidien)
Supply Code Model
Description
V901
Exhaust Gas Line Adapter for Multigas Unit AG-920/GF-110/120, tube length: 3.0 m
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
YG-920P
Combination out of sampling-line and Airway Adapter
Supply Code
Description
NKD-006324
FilterLine Set H, neonate/infant (< 2 kg), intubated, dead space: < 0.4 mL,
tube length: 2.0 m
Applicable for: Humidified environments & Long-Term Use! ICU
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
NKD-XS04620
FilterLine Set, child/adult (> 2 kg), intubated, dead space: < 6.6 mL, tube length: 2.0 m
Applicable for: Short-Terme Use - OR/EMS/ED/Transport/Rapid Response
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
NKD-XS04624
FilterLine Set, child/adult (> 2 kg), intubated, dead space: < 6.6 mL, tube length: 2.0 m
Applicable for: Humidified environments & Long-Term Use! ICU
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
Nasal Lines for non-intubated patients without oxygen supply
Supply Code
Description
NKD-009818
Smart CapnoLine, oral/nasal, child/adult (>20 kg), non-intubated, tube length: 2.0 m
Applicable for: Short-Term Use - Sedation/SleepLab/ER/EMS/ED/Transport/Rapid
Response
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
NKD-007266
Smart CapnoLine, oral/nasal, child (10-20 kg), non-intubated, no O2 tubing, tube
length: 2.0 m
Applicable for: Short-Term Use - Sedation/SleepLab/ER/EMS/ED/
Transport/Rapid Response
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
45
Patient Monitors › CO2 Measurement (Capnography)
Supply Code
Description
NKD-008177
CapnoLine H, nasal, adult (> 55 kg), non-intubated, no O2 tubing, tube length: 2.0 m
Applicable for: Long-Term Use - ICU/SleepLab
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
NKD-008178
CapnoLine H, nasal, child (10-20 kg), non-intubated, no O2 tubing, tube length: 2.0 m
Applicable for: Long-Term Use - ICU/SleepLab
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
NKD-008179
CapnoLine H, nasal, neonate/infant (< 2 kg), non-intubated, no O2 tubing,
tube length: 2.0 m
Applicable for: Long-Term Use - ICU/SleepLab
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
www.nihonkohden.net
Nasal Lines for non-intubated patients with oxygen supply
Supply Code
Description
NKD-009822
Smart CapnoLine O2, oral/nasal, adult (> 20 kg), non-intubated, tube length: 2.0 m
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
NKD-007269
Smart CapnoLine O2, oral/nasal, child (10-20 kg), non-intubated,
O2 tubing, tube length: 2.0 m
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
NKD-008180
CapnoLine H O2, nasal, adult (> 55 kg), non-intubated, O2 tubing, tube length: 2.0 m
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
NKD-008181
CapnoLine H O2, nasal, child (10-20 kg), non-intubated, O2 tubing, tube length: 2.0 m
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
46
Anesthesia Gas Measurement
www.nihonkohden.net
47
Patient Monitors › Anesthesia Gas Measurement
www.nihonkohden.net
Accessories for AG-920 & GF-110/120R
Supply Code
Description
6144-900614A
Exhaust Gas Line
For current products: GF-1x0/GF-2x0
Packing unit: 1 pcs
NKD-CALGAS
Calibration Gas incl. Valve Gas with three components in oxygen. 4% Desflurane,
6% CO2, 45% N2O balance O2. The can contains about 10 liters at about 11 bar.
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-V915A
Dryline Water Trap for Multigas Unit AG-920/GF-1x0, adult
For current products: BSM-3000/6000/9100
Packing unit: 10 pcs
NKD-V915B
Dryline Water Trap for Multigas Unit AG-920/GF-1x0, neonate/child
For current products: BSM-3000/6000/9100
Packing unit: 10 pcs
NKD-V916A
Dryline Airway Adapter for Multigas Unit GF-1x0, straight, dead space: 5 mL,
single-patient use
For current products: BSM-3000/6000/9100
Packing unit: 10 pcs
NKD-V916B
Dryline Airway Adapter for Multigas Unit GF-1x0, elbow, dead space: 7 mL,
single-patient use
For current products: BSM-3000/6000/9100
Packing unit: 10 pcs
NKD-V917A
Gas Sampling Line, adult, tube length: 2.5 m, single-patient use
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
48
Patient Monitors › Anesthesia Gas Measurement
Supply Code
Model
www.nihonkohden.net
Description
NKD-V917B
Gas Sampling Line, neonate/child, tube length: 2.5 m, single-patient use
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
NKD-V917C
Gas Sampling Line for Multigas Unit GF-1x0, adult, tube length: 3.0 m,
single-patient use
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
NKD-V917D
Gas Sampling Line for Multigas Unit GF-1x0, neonate/child, cable length: 3.0 m,
single-patient use
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
V901
YG-920P
Exhaust Gas Line Adapter for Multigas Unit AG-920/GF-1x0, tube length: 3.0 m
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
V903F
618877
Airway Adapter for Multigas Unit GF-1x0, neonate/child, dead space: 0.5 mL
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
Accessories for GF-210/220R
Supply Code
Model
Description
6114-915735
Fan Filter for GF-2x0
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
6144-900614A
Exhaust Gas Line
For current products: GF-1x0/GF-2x0
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
49
Patient Monitors › Anesthesia Gas Measurement
Supply Code
Model
Description
K977
YJ-600P
Multilink Connection Cable from Multigas Unit GF-2x0 to Monitors, cable length: 0.3 m
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
K978
YJ-601P
Multilink Connection Cable from Multigas Unit GF-2x0 to Monitors, cable length: 2.5 m
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-8290285
T-piece for GF-2x0, reusable
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-936979
Watertrap Holder (receptacle) for GF-2x0
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-V918
Watertrap for GF-2x0 disposable
For current products: BSM-3000/6000/9100
Packing unit: 12 pcs
NKD-V919
Sampling Line for Airway Adapter T-pieces V920A/B, connection to NKD-V918,
length: 3.0 m, single-patient use, for Multigas Unit GF-2x0
For current products: BSM-3000/6000/9100
Packing unit: 10 pcs
V920A
YG-620P
Airway Adapter T-Piece for Multigas Unit GF-2x0, straigth, child/adult (>10 kg),
dead space: 5 mL, requires NKD-V919, single-patient use
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
V920B
YG-621P
Airway Adapter T-Piece for Multigas Unit GF-2x0, elbow, child/adult (>14 kg),
dead space: 7 mL, requires NKD-V919, single-patient use
For current products: BSM-3000/6000/9100
Packing unit: 25 pcs
www.nihonkohden.net
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
50
Spirometry - Flow / Paw Measurement
www.nihonkohden.net
51
Patient Monitors › Spirometry - Flow / Paw Measurement
www.nihonkohden.net
Flow / Paw Measurement AF-900PA
Supply Code
Model
Description
P912
TF-910P
Flow Sensor for AF-900PA, disposable
For current products: BSM-9100
Packing unit: 1 pcs
Flow Measurement with GF-120PA/GF-220R
Supply Code
Model
Description
P913
TF-120P
Flow Adapter for Multigas Unit GF-120/220, child/adult (>14 kg),
dead space: 7.3 mL, disposable
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
P914
YF-120P
Flow Tube for Multigas Unit GF-120/220, for P913, tube length: 3.0 m, disposable
For current products: BSM-3000/6000/9100
Packing unit: 5 pcs
P915
YS-094P0 Luer Cap for Multigas Unit GF-120/220, for Flow Adapter P913, disposable
For current products: BSM-3000/6000/9100
Packing unit: 10 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
52
www.nihonkohden.net
Respiration
FiO2 Measurement & Respiration
FiO₂
Measurement
53
Patient Monitors › FiO₂ Measurement & Respiration
www.nihonkohden.net
FiO₂ Measurement
Supply Code
Model
Description
K941
JO-900P
FiO2 Connection Cable to connect P911, cable length: 3.0 m
For current products: BSM-5100/6000/9100
Packing unit: 1 pcs
P911
74705
Oxygen Sensor, cable length: 0.6 m, requires K941
For current products: BSM-5100/6000/9100
Packing unit: 1 pcs
V912
110774
T-piece Adapter for O2-Sensor P911
For current products: BSM-5100/6000/9100
Packing unit: 1 pcs
Respiration
Supply Code
Model
Description
P901
TR-900P
Respiration Pickup for Nose, cable length: 3.0 m
For current products: BSM-5100/6000/9100
Packing unit: 1 pcs
P902
TR-910P
Respiration Pickup for Airway Adapter V911, cable length: 3.0 m
For current products: BSM-5100/6000/9100
Packing unit: 1 pcs
V911
YG-001P
CO2 Airway Adapter for P901/P902, thermistor method
For current products: BSM-5100/6000/9100
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
54
www.nihonkohden.net
IBP
IBP & ICP Measurement
(Invasive Blood Pressure & Intracranial Pressure)
Blood pressure (BP) is the pressure exerted by circulating blood against the artery walls. During each heartbeat, the blood
pressure varies between a maximum (systolic) and a minimum (diastolic) pressure. The variation indicates the condition of
the pumping function of the heart as an important vital sign.
A direct method to measure the blood pressure is the invasive blood measurement using catheters inserted into the blood
vessels, filled with saline solution and measure the pressure electrically with a connected transducer.
ICP
55
Patient Monitors › IBP & ICP Measurement
www.nihonkohden.net
IBP Transducer Cable with Direct Connection
Supply Code
Model
Description
K951
JP-900P
IBP Connection Cable for Becton Dickinson Transducers, cable length: 3.5 m
Applicable for Becton Dickinson (Ohmeda) Transducers: all current models:
Series DTX/Plus & Series RT2000; older models: Series P23XL
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
K952
JP-910P
IBP Adapter Cable for IBP Transducer Cables, BF type, cable length: 0.3 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
K957
JP-960P
IBP Connection Cable for Biosensors Transducers, cable length: 3.5 m
Applicable for Biosensors Transducers: Series Biotrans & Series Accutrans
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
L901
JP-920P
IBP Connection Cable for Edwards Lifesciences Transducers, cable length: 3.5 m
Applicable for Edwards Lifesciences Transducers:
Series TruWave: PX-600P, PX-600F30, PX-600P
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
L902
JP-921P
IBP Connection Cable for Edwards Lifesciences Transducers, cable length: 1.5 m
Applicable for Edwards Lifesciences Transducers:
Series TruWave: PX-600P, PX-600F30, PX-600P
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
56
Patient Monitors › IBP & ICP Measurement
www.nihonkohden.net
IBP Transducer Cable with Adapter Cable K952
Supply Code
Description
NKD-5203201
IBP Connection Cable for B. Braun Transducers, cable length: 3.0 m, requires K952
Applicable for B. Braun Transducers: Series Combitrans, Series Combidyns
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-BDP178NK1
IBP Connection Cable Set for Codan Transducers,
incl. adapter cable with 1 Pressure Connection, contact
board X-trans BDC 901 and holding plate B180090,
cable length: 0.5 m, requires K952
Applicable for Codan Transducers:
Series xTrans: DPT-9003, DPT-9009, DP 9300, DPT-9990
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 set
NKD-BDP178NK4
IBP Connection Cable for Codan Transducers with 4 Pressure Connections,
cable length: 0.5 m, requires K952
Applicable for Codan Transducers:
Series xTrans: DPT-9003, DPT-9009, DPT-9300, DPT-9990
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-BDPT-1078
IBP Connection Cable for Codan Transducers with 4 Pressure Connections,
cable length: 3.5 m, requires K952
Applicable for Codan Transducers: Series xTrans: DPT-6000
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/LOGICAL
IBP Connection Cable for Medex Transducers with 1 Pressure Connection,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Logical
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/LOGICAL2
IBP Connection Cable for Medex Transducers with 2 Pressure Connections,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Logical
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/LOGICAL3
IBP Connection Cable for Medex Transducers with 3 Pressure Connections,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Logical
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
57
Patient Monitors › IBP & ICP Measurement
Supply Code
Model
NKD-IBP/LOGICAL4
NKD-IBP/NOVATRANS
www.nihonkohden.net
Description
IBP Connection Cable for Medex Transducers with 4 Pressure Connections,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Logical
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
MX901-22
IBP Connection Cable for Medex Transducers with 1 Pressure Connection,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Novatrans
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/TRANSPAC
IBP Connection Cable for TRANSPAC Transducers with 1 Pressure Connection,
cable length: ca. 4.5 m, requires K952
Applicable for Abbott Transducers: Transpac IT, Transpac IV
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/TRANSTAR
IBP Connection Cable for Medex Transducers with 1 Pressure Connection,
cable length: 4.0 m, requires K952
Applicable for Medex Transducers: Series Transtar
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/UTAH
IBP Connection Cable PMK225 for Pulsion Transducers for Picco2
and Piccoplus with 1 Pressure Connection, cable length: 3.0 m,
requires K952 & 2NKD-IBP/UTAH2
Applicable for Pulsion Transducers for PICCO: PV81x, PV82xx
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
NKD-IBP/UTAH2
AUX Adapter Cable PC85200 to External Monitor for Pulsion Picco 2,
cable lenghth: 0,3 m, requires NKD-IBP/UTHA
For current products: all BSM/PVM-2703/TEC-8300
Packing
acking unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
58
Patient Monitors › IBP & ICP Measurement
www.nihonkohden.net
ICP Standard Adapter Cable
Supply Code Model
Description
K952
IBP Adapter Cable for IBP Transducer Cables, BF type, cable length: 0.3 m
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
JP-910P
ICP Sensor Cable for BSM-9100
Supply Code
Description
JP-911P
ICP Sensor Cable, CF type, for use with Integra LS ICP monitors
For current products: BSM-9100
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
59
www.nihonkohden.net
Cardiac
Cardiac Output (C.O.)
Output
60
Patient Monitors › Cardiac Output (C.O.)
www.nihonkohden.net
Cardiac Output (C.O.)
Supply Code
Model
Description
K962
JT-950P
C.O. Connection Cable for Becton Dickinson/Edwards Lifesciences, cable length: 2.0 m
For current products: all BSM
Packing unit: 1 pcs
NKD-ED/93528
Edwards Lifesciences Injectate Sensor Cable, cable length: 2.43 m
For current products: BSM-3000/5100/6000/9100
Packing unit: 1 pcs
NKD-SP4045
Becton Dickinson Inline Injection Sensor Cable B, BD DTXPlus, latex-free,
cable length: 2.43 m, requires K962
For current products: all BSM
Packing unit: 1 pcs
NKD-SP4572
Becton Dickinson Room Temperature Injection Kit, requires K962
Kit Contains: Injection Sensor Housing (NKD-SP5045) - 25 pcs, BD Spectraject™ Disposable 10cc Control Syringe with BD Touchguard™ Sheath for hand injections of contrast
media (682260)- 10 pcs
For current products: all BSM
Packing unit: 5 kits
NKD-SP5045
Becton Dickinson Injection Sensor Housing for Inline Injective Temperature
Measurement, requires NKD-SP4045
For current products: all BSM
Packing unit: 25 pcs
NKD-SP5107H
Becton Dickinson Thermo Dilution Catheter 7F, size: 2.33 mm dia, 4 lumes,
tube length: 1.1 m, requires K962
For current products: all BSM
Packing unit: 5 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
61
Patient Monitors › Cardiac Output (C.O.)
Supply Code
Description
NKD-SP5107H-IS
Becton Dickinson Thermo Dilution Catheter 7F with Inline Sensor NKD-SP5045,
size: 2.33 mm dia, 4 lumes, tube length: 1.1 m, requires K962
For current products: all BSM
Packing unit: 5 pcs
SP-4035-1
C.O. Extension Cable, cable length: 1.0 m
For current products: all BSM
Packing unit: 1 pcs
www.nihonkohden.net
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
62
www.nihonkohden.net
EEG Measurement
EEG measurements are increasingly used in intensive care units to monitor the brain activity trend at a glance giving
valuable information such as simple pattern recognition between normal and abnormal brain activity for the daily routine.
63
Patient Monitors › EEG Measurement
www.nihonkohden.net
2-channel EEG
Supply Code Model
Description
L461
JE-905P
EEG connection Cable, 2 channel, cable length: 3.0 m, for AE-910P/918P
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
K461
BE-930P
EEG Electrode Lead for Disposable Electrodes, for AE-910P/918P, snap,
cable length: 0.8 m
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
H471
BE-910P
Disk Electrodes for AE-918P, cable length: 0.8 m
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
H472
BE-920P
Collodion Electrodes for AE-918P, cable length: 0.8 m
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
64
Patient Monitors › EEG Measurement
www.nihonkohden.net
8-channel EEG
Supply Code Model
Description
L462
JE-906P
EEG connection Cable, 8 channel, cable length: 3.0 m, for AE-910P/918P
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
H503B
NE-114A
EEG Disk Electrode for EOG & EMG, Ag, w/ DIN connector, cable length: 0.8 m
For current products: all EEG/MEE-1000/BSM-3000/6000/9100
Packing unit: 1 pcs
H527
NE-136A
Surface Electrode, Ag, DIN connector, for all EEG, cable length: 0.7 m
For current products: EEG-1200/9100/BSM-3000/6000/9100
Packing unit: 12 pcs
H537A
NE-224S
Needle Electrode for EEG & EP, stainless steel, w/ DIN connector,
needle length: 12 mm, cable length: 1.5 m
For current products: EEG-1200/9100/MEB-9200/9400/BSM-3000/6000/9100
Packing unit: 20 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
65
Patient Monitors › EEG Measurement
www.nihonkohden.net
Further EEG Accessories
Please contact us for an individual offer based on your annual volume! Use the possibility of call orders!
Supply Code Model
Description
F020
YZ-0019
“SkinPure” Skin Preparation Gel, reduces the electrode skin impedance, 135 g tube
Packing unit: 2 pcs
F509
Z-181JE
Elefix EEG Conduction Paste, 180 g tube
Packing unit: 1 pcs
F510
Z-401CE
Elefix EEG Conduction Paste, 400 g cup
Packing unit: 1 pcs
NKD-EC2
Conductive Grass Paste EC2 for long-term EEG measurements, 100g tube
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 10 pcs
NKD-NPREP
Skin Preparation Gel for Neonates, 114g tube
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 3 pcs
NKD-AR205
Adhesive ECG Rings, size: 20 x 5 mm
For current products: all ECG/EEG/BSM-3000/6000/9100
Packing unit: 500 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
66
Patient Monitors › EEG Measurement
Supply Code
Description
NKD-BN100
Original BraiNet S, child/adult, 46 - 54 cm circumference, 14 electrodes
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-BN101
Original BraiNet L, child/adult, 54 - 62 cm circumference, 14 electrodes
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-BN106
10 - 20 BraiNet, child/adult, 45.5 - 49 cm circumference, 21 electrodes
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-BN107
10 - 20 BraiNet, child/adult, 49.5-54 cm circumference, 21 electrodes
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-BN108
10 - 20 BraiNet, child/adult, 54.5 - 57 cm circumference, 21 electrodes
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-BN109
10 - 20 BraiNet, child/adult, 57.5 - 62 cm circumference, 21 electrodes
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
www.nihonkohden.net
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
67
Patient Monitors › EEG Measurement
Supply Code
Description
NKD-BN111
Baby BraiNet 1, NICU, 25 - 29 cm circumference, 14 electrodes
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-BN112
Baby BraiNet 2, NICU, 29.5 - 33 cm circumference, 14 electrodes
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-BN113
Baby BraiNet 3, NICU, 33.5 - 37 cm circumference, 14 electrodes
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-BN114
Baby BraiNet 4, NICU, 37.5 - 41 cm circumference, 14 electrodes
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-BN115
Baby BraiNet 5, NICU, 41.5 - 45 cm circumference, 14 electrodes
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-BN500
Baby BraiNet Jack Box Overlay, adhesive colored stickers for jack box port customization
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-BN505
10/20 BraiNet Jack Box Overlay, adhesive colored stickers for jack box port customization
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 1 pcs
www.nihonkohden.net
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
68
www.nihonkohden.net
Mandatory Accessories for TOF-Interface
BIS & TOF Measurement
The bispectral index (BIS) monitors the depth of anesthesia by processing raw EEG data, obtained through a sensor placed on
the patient’s forehead. A calculated number between 0 and 100 provides a direct measure of the patient’s level of consciousness
and response to sedation. Whereas a BIS value of 100 indicates the patient is fully awake, a value of 0 indicates the absence of
brain activity.
When admistering a neuromuscular blocking, TOF measurement should be used during all phases of general anesthesia from
induction to maintenance, and through to the end of a surgical procedure to monitor the degree of neuromuscular blockade. It
may help detect remnant blockades linked to airway problems, ventilator failure and further postoperative complications such
as severe hypoxemia or pneumonia.
BIS Measurement
Further TOF Accessories
69
Patient Monitors › BIS & TOF Measurement
www.nihonkohden.net
BIS Measurement
Please order BIS Sensors from your local BIS Supplier! Only initial sales packing units can be provided by NIHON KOHDEN!
Supply Code
Description
NKD-L572
Pic Plus Patient Interface Cable for BisX to connect to the BISx and to BIS Sensors
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
TOF Measurement
Mandatory Accessories for TOF Interface
Supply Code
Description
NKD-TOF/CONNECTION
CABLE
TOF Connection Kit, incl.NKD-5750005, NKD-5750031 - TOF Link Cable 3.0 m,
TOF Watch SX Interface RS232 Adapter
For current products: BSM-3000/6000/9100
Packing unit: 1 kit
QF-909P
Interface Cable for TOF
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
Further Accessories for TOF
Facts
TOF Application Help
Place the stimulation electrodes G210C over the Nerve Ulnaris on the volar side of the wrist. The distal electrode is positioned where the proximal
bending line crosses the radial side of the flexor carpi ulnaris muscle. Place the electrodes on each side of the expected position of the ulnar nerve
(2 to 3 cm distance). Softly press the electrodes to ensure good fitting.
Fix the transducer (is part of supply code NKD-79950213) to the thumb by putting the flat side to the thumb. Take care that no traction is applied
and that movement of the thumb is not obstructed. Small sideway movements of the thumb may be noticed during stimulation. If this is the case,
reposition the transducer in such a way that the movement is perpendicular. The more distal the transducer is placed on the thumb, the stronger the
acceleration signal is. This effect can be used to adjust the signal strength.
During the measurement, the arm should be immobile and fixed to the OR table or by the hand adapter NKD-79950209.
Supply Code
Model
Description
G210C
F-150S
ECG Electrode Vitrode F, Ag/AgCl, neonate/child, size S: 18 x 36 mm, cotton tape
especially for sensitive skin, adhesive gel
For current products: all EEG/BSM-3000/6000/9100
Packing unit: 3 x 50 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
70
Patient Monitors › BIS & TOF Measurement
Supply Code
Model
NKD-TOF/
CONNECTION
CABLE
www.nihonkohden.net
Description
TOF Connection Kit, incl. NKD-5750005, NKD-5750031 TOF Link Cable 3.0 m, TOF Watch SX Interface
RS232 Adapter
For current products: BSM-3000/6000/9100
Packing unit: 1 kit
NKD-5750031
G001034
TOF Watch Interface RS232 Adapter
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-5750005
79950154
TOF Link Cable, cable length: 3.0 m
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-G001099
5750006
TOF Fixation Clamp
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-G016094
5750014
TOF Fix Advanced Clamp (to fix to the OR Table)
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-G010104
5750011
TOF Holder for IV-Pole
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-79950001 7995001
TOF Splint for Watch and Guard
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
71
Patient Monitors › BIS & TOF Measurement
Supply Code
Model
www.nihonkohden.net
Description
NKD-79950209 79950209
TOF Hand Adapter
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
NKD-79950217
79950217
TOF Elastic Band to fix the Hand Adapter NKD-79950209
For current products: BSM-3000/6000/9100
Packing unit: 10 pcs
NKD-79950152
79950152
TOF Thumb Adapter
For current products: BSM-3000/6000/9100
Packing unit: 50 pcs
NKD-79950207 79950207
TOF Eye Adapter
For current products: BSM-3000/6000/9100
Packing unit: 50 pcs
NKD-79950213
79950213
TOF Complete Wire Set incl. patient cable, white-black transducer,
with thermostat
For current products: BSM-3000/6000/9100
Packing unit: 1 set
NKD-5750027
5750027
TOF Complete Wire Set, white and black electrode lead,
transducer, without thermistor cable
For current products: BSM-3000/6000/9100
Packing unit: 1 set
NKD-5750019
79950208
TOF Link cable, cable length: 0.25 m
For current products: BSM-3000/6000/9100
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
72
www.nihonkohden.net
Batteries & Battery Charger
Further Accessories
Power Cable
Analog Output Cable
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
73
Patient Monitors › Further Accessories
www.nihonkohden.net
Recording Paper
Supply Code Model
Description
A226
FQS502-100
Thermal Paper, Z-fold, 50 mm x 20 m (page 100 mm), orange grid
For current products: TEC-5500/BSM-2300/-3000
Packing unit: 10 pcs
A721
FQW502-100
Recording Paper, 50 mm x 20 m
For current products: BSM-3000/6000/9100/all PVM
Packing unit: 10 pcs
NKD-A723
FQW503-100
Thermal Paper, Z-fold, 50 mm x 30 m (page 100mm), w/o grid
For current products: BSM-2300/5100/OPV-1500
Packing unit: 10 pcs
A810
QW60-2
Recording Paper, 60 mm x 20 m
For current products: OPV-1500
Packing unit: 10 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
74
Patient Monitors › Further Accessories
www.nihonkohden.net
Batteries & Battery Charger
Supply Code Model
Description
X060
NKB-101
Battery Pack, 12V, 1700 mAh, nickel-cadmium (NiCd), rechargeable
For current products: BSM-4100/5100
Packing unit: 1 pcs
X062
YS-076P5
Battery Pack, 12V, 3700 mAh, nickel-metal hydride (NiMH), rechargeable
For current products: BSM-2300
Packing unit: 1 pcs
X072
YS-085P6
Battery Pack, 12V, 2040 mAh
For current products: OLV-2700/OLG-2800
Packing unit: 1 pcs
X075
SB-671P
Battery Pack, 9.6V, 2900 mAh
For current products: BSM-3000/6000/WEP-520x
Packing unit: 1 pcs
X076
SB-201P
Battery Pack, 9.6V, 3700 mAh
For current products: all BSM/PVM-2703/TEC-8300
Packing unit: 1 pcs
SB-201VK
External Battery Charger, for one battery X060
For current products: BSM-4100/5100
Packing unit: 1 pcs
SB-610RK
Battery Charger, for X075 Batteries
For current products: BSM-3000/6000/WEP-5200
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
75
Patient Monitors › Further Accessories
www.nihonkohden.net
Analog Output Cable
Supply Code Model
Description
K974
YJ-910P
ECG/BP Output Cable, cable length: 5.0 m
For current products: BSM-3000/5100/6000/9100
Packing unit: 1 pcs
K975
YJ-920P
ECG/BP Output Cable with Phone Jack, cable length: 0.3 m
For current products: BSM-3000/5100/6000/9100
Packing unit: 1 pcs
Power Cable
Supply Code
Description
NKD-L936
Power Cable, Schuko plug, cable length: 2.0 m
Packing unit: 1 pcs
NKD-POWER
CABLE 1.5
Power cable with L-Connector, cable lenght: 1.5 m
Packing unit: 1 pcs
NKD-POWER
CABLE 2.0
Power cable with L-Connector, cable lenght: 2.0 m
Packing unit: 1 pcs
Pens
Supply Code Model
Description
Y011
404617
Thermal Head Cleaner Pen
For current products: all ECG/TEC/old MEB/EEG/all BSM/PVM/OPV/WEP
Packing unit: 1 pcs
Y075
YZ-0254
Touch Pen, incl. cord & touch pen holder, for easy use of touch screen monitors
For current products: all BSM/PVM/OPV
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
76
Accessories for Transmitters
Please contact us for an inividual offer based on your annual volume! Use the possibility of call orders!
www.nihonkohden.net
77
www.nihonkohden.net
ECG Measurement
Highly accurate ec1 arrhythmia analysis
NIHON KOHDEN’s ec1 arrhythmia analysis provides superior elimination of false
alarms. ec1 has been evaluated with worlds standard arrhythmia databases as well as
NIHON KOHDEN’s ECG database, with a result of 80% reduction of false alarms.
Number of false alarms
3000
2500
V. Rhythm
Tachy
2000
VPC Run
1500
VT
Ext. Tachy
1000
VF
500
0
Without ec1
With ec1
78
www.nihonkohden.net
ECG Cables
3/6-Lead
ad
12-Lead
79
Transmitters › ECG Measurement
www.nihonkohden.net
ECG 3 -Lead Cables for ZS-910/-920/-930/-530PG; ZM-920/-930/-940PG
Supply Code Model
Description
K120
NA-0003
Electrode Lead Tube, for K911/K910A
For current products: TEC-55/77/8300/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 5 pcs
K910A
BR-913P
3-Lead ECG Electrode Cable, snap, cable length: 0.8 m
TEC-55/7700: for connection to defibrillators L153 is required
BSM/PVM/TEC-8300: for connection to monitors K922 is required
For current products: TEC-55/77/8300/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 1 pcs
K911
BR-903P
3-Lead ECG Electrode Cable, clip, cable length: 0.8 m
TEC-55/7700: for connection to defibrillators L153 is required
BSM/PVM/TEC-8300: for connection to monitors K922 is required
For current products: TEC-55/77/8300/all BSM/PVM;
ZS-910/920/930/940/530PG; ZM-920/930/940PG
Packing unit: 1 pcs
ECG 6-Lead Cables for ZM-920/-930/-940PG
Supply Code Model
Description
K912
BR-906P
6-Lead ECG Electrode Cable, clip, cable length: 0.8 m, requires K922
For current products: all BSM/PVM/TEC-8300; ZM-920/930/940PG
Packing unit: 1 pcs
K915
BR-916P
6-Lead ECG Electrode Cable, snap, cable length: 0.8 m, requires K922
For current products: all BSM/PVM/TEC-8300; ZM-920/930/940PG
Packing unit: 1 pcs
Leads, Cables and Cords
Note: Do not touch the socket pin. Do not wet the socket.
Cleaning the Leads, Cables and Cords
• Wipe with a soft cloth moistened with neutral soap, water or alcohol
and wipe with a dry cloth or gauze.
Disinfecting the Leads, Cables and Cords
• Wipe with a non-abrasive cloth moistened with any of the
disinfectants listed below. Use the recommended concentration.
Disposing of Leads, Cables and Cords
• For detailed information about disposal, contact your NIHON KOHDEN
representative.
Disinfectant
Concentration %
Chlorhexidine gluconate solution
0.5
Benzethonium chloride solution
0.2
Glutaraldeyde solution
2.0
Benzalkonium chloride
0.2
Alkyldiaminoethylgycine hydrochloride
0.5
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
80
www.nihonkohden.net
ECG Electrodes
NIHON KOHDEN VITRODE Disposable ECG Electrodes –
The result of over 30 years experience in disposable electrode manufacturing.
The ECG electrodes are the most important portions of the ECG/arrhythmia monitoring system. It is through these electrodes that the electrical signals are conducted from the patient and into the monitoring system. If the electrodes are
left in place for an extended periode of time (over 48 hours), or they are reused once they are removed, they do not adhere to the patient’s skin and they causes “noisy’’ ECG signals because of the poor conduction. In addition, the patient’s
movement causes the electrodes to lose conducting capabilities intermittently, and this leads to a “wandering’’ ECG
waveform and muscle artifact. The standard monitoring practice is to change these electrodes at least every 48 hours.
Please contact us for individual offer based on your anual volume! Use the possibility of call orders!
81
Transmitters › ECG Measurement
www.nihonkohden.net
Standard Electrodes Placements
It is important to prepare the skin before attaching
the electrodes by cleaning it and removing chest
hair. After this please attach the lead wire to the
electrodes before placing them on the skin. This
avoids pain to the patient. Secure the lead wire to
the skin (stress loop) preventing moving of the lead
wire and therefore noise on the ECG signal.
Three electrodes
Six electrodes
Ten electrodes
ECG Electrodes for ZS-910/-920/-930/-530PG; ZM-920/-930/-940PG
Supply Code Model
Description
G203
L-150
ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, foam tape, solid gel
general use
Packing unit: 5 x 30 pcs
G204
C-150
ECG Electrode Vitrode C, Ag/AgCl, adult, size: 47 mm dia, breathable cottony softcloth,
solid gel with an elastic quality for tension
Packing unit: 5 x 30 pcs
G207
L-150X
ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, radiolucent (X-ray, MRI, CT),
foam tape, solid gel
Packing unit: 5 x 30 pcs
G210D
F-150M
ECG Electrode Vitrode F, Ag/AgCl, adult, size M: 25 x 45 mm, cotton tape especially for
sensitive skin, adhesive gel
Packing unit: 3 x 50 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
82
Transmitters › ECG Measurement
Supply Code Model
Description
G236
M-150
ECG Electrode Vitrode M, Ag/AgCl, child/adult, size: 40 mm dia, foam tape,
higbrid gel, for stress test
Packing unit: 5 x 30 pcs
G250
J-150
ECG Electrode Vitrode J, Ag/AgCl, adult, size: 40 mm dia, foam tape, solid gel, excellent
adhesion even on sweaty skin
Packing unit: 5 x 30 pcs
G210C
F-150S
ECG Electrode Vitrode F, Ag/AgCl, neonate/child, size S: 18 x 36 mm, cotton tape
especially for sensitive skin, adhesive gel
Packing unit: 3 x 50 pcs
www.nihonkohden.net
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
83
www.nihonkohden.net
SpO₂ Measurement
Pulse Oximeter is a non-invasive device used to percutaneously measure oxygen saturation
in the blood by use of a clip-on finger probe. Pulse oximeter works with the integration of
a probe placed onto patient’s fingertip or toe, obtains signals from the probe and the main
device calculates oxygen saturation in the body.
Oxygen saturation measured by pulse oximeter is SpO₂. “P” stands for “pulse”, and the measurement principle is based on beat-by-beat changes in blood volume. In general, arterial
oxygen saturation measured by spectroscopic analysis is called “SaO₂”, and oxygen saturation measured by pulse oximeter is called “SpO₂”.
The method for determination of arterial oxygen saturation, based on the photoelectric plethysmography, was conceptualised and implemented in 1972 by the Japanese bio-engineer
Takuo Aoyagi (NIHON KOHDEN Corporation). This idea came about while using an ear densitometer for recording dilution curves for dyes (pigments). The first commercial oximeter
“OLV-5100” was presented by NIHON KOHDEN back in 1975.
Dr. Aoyagi’s innovative technology, pulse oximetry, has rapidly spread worldwide and become essential in critical care. In
2002, Dr. Aoyagi was awarded the Medal of Honor in Japan, in recognition of his great contribution to clinical medicine.
The NIHON KOHDEN SpO₂ Sensors of the BluPRO® Series are at the cutting edge of this progressive technology.
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
84
www.nihonkohden.net
SpO₂ Probes
BluPRO® SpO₂ Probes – A Unique Sensing Technology
Reliability and high quality of our probes provide a continuous accurate and safe monitoring with highest patient
comfort. The comfortable, sure fitting and lightweight characteristic reduces the effect of hand movement for
highly reliable SpO2 measurement.
This ensures patient safety, reduces the costs of care and increases therefore clinical efficiency and cost
effectiveness. NIHON KOHDEN BluPRO® SpO2 Probes are comfortable, durable, accurate and needs-oriented.
Note that accurate and safe measurement is assured only when you use probes, connection cords and parts manufactured by NIHON KOHDEN. Some probes in the market may advertise as „compatible with NIHON KOHDEN
probes.“ We strongly recommend you to avoid these probes as a correct measurement cannot be guaranteed on
NIHON KOHDEN devices. NIHON KOHDEN is not responsible for trouble caused by using other manufacturer’s probes.
Please contact us for an individual offer based on your annual volume! Use the possibility of call orders!
Disposable
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
Transmitters › SPO2 Measurement
www.nihonkohden.net
SpO₂ Probes
ing
Child
Adult
)
(m
Disposable
Infant
it
un
h
gt
len
l)
de
Mo
(
de
ck
Pa
Co
ble
Ca
ly
pp
Su
Low birth Neonate
weight
1000 g
P203A (TL-271T)
0.8
P203E (TL-271T3)
1.6
P204A (TL-271T)
0.8
P204E (TL-271T3)
1.6
P203B (TL-272T)
0.8
P203F (TL-272T3)
1.6
P204B (TL-272T)
0.8
P204F (TL-272T3)
1.6
P203C (TL-273T)
0.8
P203G (TL-273T3)
1.6
P204C (TL-273T)
0.8
P204G (TL-273T3)
1.6
P203D (TL-274T)
0.8
P203H (TL-274T3)
1.6
P204D (TL-274T)
0.8
P204H (TL-274T3)
1.6
P228A (TL-051S)
0.8
P228B (TL-052S)
1.6
P229A (TL-061S)
0.8
P229B (TL-062S)
1.6
P205A (TL-260T)
1.6
P260A (Tape S)
1.6
P225H (TL-201T1)
0.6
1.6
P311C (TL-631T3)
1.6
P310C (TL-630T3)
1.6
10 kg
20 kg
30 kg
40 kg
50 kg
24
5
24
5
24
5
5
5
5
1
P225G (TL-220T)
3 kg
5
P256
P225F (TL-201T)
2 kg
24
24
P260B (Tape L)
Reusable
85
Tape S
Tape L
Tape S
With P205A ear clip
86
Transmitters › SpO2 Measurement
www.nihonkohden.net
SpO₂ Measurement with ZS-930/-940/-530PG; ZM-930/-940PG
Reusable SpO₂ Probes
Reusable, but always clean – NIHON KOHDEN washable probes.
The reusable Probes of the BluPRO® series are durable and washable,
so you can clean them under running water or even immerse them in a
soapy alkaline or disinfectant solution (glutaraldehyde solution 2.0 %
or hydrochloric alkyl diaminoethylene glycine 0.5 %)!
P225F / P 225H
P225G
P310C / P311C
Durable, washable, needs-oriented!
Facts
NIHON KOHDEN reusable SpO2 finger-clips probes have paraellel mounted upper and lower sensor shells, thus, providing on the one hand,
exact alignment of the optical sensor components vis-à-vis one another and on the other hand, markedly enhanced comfort during long-term
attachment. In addition, flexible lateral flaps shield the measuring signals from the external light, thus resulting to minimize the interference
by additional artificial light sources! Bright LEDs provide more accurate measurement even for thicker fingers or dark skin tones. The finger-clip
reusable probe is the most popular type of SpO2 probes. Instead of the typical hinge near the finger tip, P225F/P225H have a unique sure fitting
and comfortable mechanism using two sliding pieces for the front and back of the finger with two rubber flaps along both sides of the finger.
When you press the button, the two halves of the probe slide directly open, parallel to each other. No additional fixation tape is needed. For a stable and
comfortable measurement P225F/P225H, always keep the light emitters and detector aligned. NIHON KOHDEN provides unique reusable SpO2 probes.
Supply Code Model
Description
P225F
TL-201T
SpO₂ BluPRO® Finger-Clip Probe, child/adult (> 20 kg) finger, cable length: 1.6 m,
reusable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 1 pcs
P225H
TL-201T1
SpO2 BluPRO® Finger-Clip Probe, child/adult (> 20 kg) finger, cable length: 0.6 m,
reusable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 1 pcs
Facts
The multi-site probe P225G can be used for neonatal feet as well as adult fingers as its curved contact surface is designed to fits on different attachment
sites. The light emitter and detector are separate which allows especially an accurate alignment of the LED on the infant/neonatal instep. A unique sliding
adjuster gives the best fit on the attachment site secured by taping.
Supply Code Model
Description
P225G
SpO2 BluPRO® Multi-Site Probe, neonate (< 3 kg) instep, child/adult (> 3 kg) finger/toe,
cable length: 1.6 m, reusable
For current products: all BSM/PVM/TEC/EEG;
ZS-930/530/940PG; ZM-930/940PG
Packing unit: 1 pcs
TL-220T
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
87
Transmitters › SpO2 Measurement
www.nihonkohden.net
Facts
Our special designed finger-tip probes, P310C and P311C, fit immediately on the finger and are perfect for long-term measurement. A less covered finger
area and cushioned materials lead to decrease pressure to the attachment site. The 3D molding attachment ensures a comfortable fit.
In combination with the soft and lightweight design the patient stress or discomfort is reduced and the probes can be remained up to 8 hours to one attachment site. A stable measurement is assured by gentle fixation tapes P263 or P267 that avoid the falling off of the probes and reduce artefacts from cable
movement.
Reusable but with the comfort of a disposable probe, P310C and P311C are also applicable for sleep studies, for patients that are often bending their fingers
or obese patients.
Supply Code Model
Description
P310C
TL-630T3
SpO2 BluPRO® Finger-Tip Probe L, child/adult (> 50 kg) finger, cable length: 1.6 m,
long-term use, reusable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 1 pcs
P311C
TL-631T3
SpO2 BluPRO® Finger-Tip Probe M, child/adult (> 20 kg) finger, cable length: 1.6 m,
long-term use, reusable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 1 pcs
P263
P267
Disposable Probe Cable Fixing Tape for P310C/P311C, size: 15 x 130 mm
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 3 x 30 pcs
YS-093P2
Reusable Probe Fastener Tape for P310C/P311C,
size: 15 x 140 mm
For current products: all BSM/PVM/TEC/EEG;
ZS-930/530/940PG; ZM-930/940PG
Packing unit: 30 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
88
Transmitters › SpO2 Measurement
www.nihonkohden.net
Facts
The multi-site probe P205A can be used for SpO2 measurement for children and adults as well as for prematures in combination with special attachment
tapes. For measuring SpO2 on children or adults with P205A, the ear clip P256 is required.
The ear clip is designed to hold the light emitters and detector of the probe P205A and be clipped onto the earlobe of the patient. P256 is intended for
use when SpO2 measurement on a finger or toe is difficult and the patient is at rest with little body movement. The P205A can be inserted in the special
designed slots on the ear clip without sticking out of the clip edge. A secure fit is provided by additional cable slots, silicone surfaces for the earlobe and
supplementary fixation of the cable with tape near the earlobe. The multi-site probe is intended for single-patient use and needs to be replaced after each
patient measurement. The ear clip can be reused. Clean it after every use with a soft cloth moistened with 70% ethanol solution. Dry the clip thoroughly
after cleaning.
Supply Code Model
Description
P205A
TL-260T
SpO2 Multi-Site Probe, cable length: 2.0 m, neonate (< 3kg ) instep, child/adult
(> 3 kg) finger/toe, fixed with P260A/B or for P256, single-patient use
For current products: all BSM/PVM/TEC/EEG
Packing unit: 5 pcs
P256
6143-012434 SpO2 Ear-Clip for P205A , child/adult (> 30 kg)
For current products: all BSM/PVM
Packing unit: 1 pcs
Disposable SpO₂ Probes
NIHON KOHDEN disposable probes, from neonate to adult sizes, place special emphasis on the exact positioning of the LEDs and
detector. For this reason the two optical components are designed separately and can thus be brought into precise alignment with
each other by the user. All probes have breathable material and can be remained up to 8 hours on one attachment site. Paediatric
probes have a cute cartoon character printed on the tape to reassure children.
Self-adhesive, soft and thin tape provides a secure fit. The special design allows an easy application to the attachment site. To get
the most comfortable fit, please bend the probe before attaching, do not strongly pull the attachment tape when attaching and do
not push the tip of the finger with the attachment tape.
Disposable SpO₂ Probes 24 pcs/box – cable length: 0.8 m
Supply Code Model
Description
P203A
TL-271T
SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
P203B
TL-272T
SpO2 BluPRO® Probe, child (10 – 50 kg) finger/toe, cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
89
Transmitters › SpO2 Measurement
Supply Code Model
Description
P203C
TL-273T
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
P203D
TL-274T
SpO2 BluPRO® Probe, infant (3 – 20 kg) finger/toe, cable length: 0.8 m,
disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
Disposable SpO₂ Probes 24 pcs/box - cable length: 1.6 m
Supply Code Model
Description
P203E
TL-271T3
SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
P203F
TL-272T3
SpO2 BluPRO® Probe, child ( 10 – 50 kg) finger/toe, cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
P203G
TL-273T3
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe, cable length:
1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
P203H
TL-274T3
SpO2 BluPRO® Probe, infant (3 – 20 kg) finger/toe, cable length: 1.6 m
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
Disposable SpO₂ Probes 5 pcs/box - cable length: 0.8 m
Supply Code Model
Description
P204A
SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
TL-271T
www.nihonkohden.net
90
Transmitters › SpO2 Measurement
Supply Code Model
Description
P204B
TL-272T
SpO2 BluPRO® Probe, child (10 – 50 kg) finger/toe, cable length: 0.8 m,
disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P204C
TL-273T
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P204D
TL-274T
SpO2 BluPRO® Probe, infant ( 3 –20 kg) finger/toe, cable length: 0.8 m
disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
www.nihonkohden.net
Facts
Absolutely cost-effective, the series P228 and P229 are intended for long-term measurement on a single patient. The probes do not need to be replaced
with a new one before 96 hours by changing the attachment site every 8 hours. So your running costs can be reduced!
The light emitter and detector are covered by sponge and the entire attachment site has a flat surface. This reduces the risk of skin burn and irritation.
Since the probe itself is not self-adhesive, you can easily remove and attach the probe to change the attached finger. For fixation, wrap the probe around
the finger with attachment tape P259.
Supply Code Model
Description
P228A
TL-051S
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 50 kg) finger,
cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P229A
TL-061S
SpO2 BluPRO® Probe, infant/child (3 – 15 kg) toe, child (15 – 50 kg) finger,
cable length: 0.8 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P259
COTTONY Tape for fixing disposable SpO2 Probes, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940OPG; ZM-930/940PG
Packing unit: 20 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
91
Transmitters › SpO2 Measurement
www.nihonkohden.net
Disposable SpO₂ Probes 5 pcs/box - cable length: 1.6 m
Supply Code Model
Description
P204E
TL-271T3
SpO2 BluPRO® Probe, adult (> 30 kg) finger/toe, cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P204F
TL-272T3
SpO2 BluPRO® Probe, child (10 – 50 kg) finger/toe, cable length: 1.6 m,
disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P204G
TL-273T3
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) finger/toe,
cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P204H
TL-274T3
SpO2 BluPRO® Probe, infant (3 – 20 kg) finger/toe, cable length: 1.6 m,
disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
Facts
Absolutely cost-effective, the series P228 and P229 are intended for long-term measurement on a single patient. The probes do not need to be replaced
with a new one before 96 hours by changing the attachment site every 8 houers. So your running costs can be reduced! The light emitter and detector
are covered by sponge and the entire attachment site has a flat surface. This reduces the risk of skin burn and irritation. Since the probe itself is not
self-adhesive, you can easily remove and attach the probe to change the attached finger. For fixation, wrap the probe around the finger with attachment
tape P259.
Supply Code Model
Description
P228B
TL-052S
SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 50 kg) finger,
cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P229B
TL-062S
SpO2 BluPRO® Probe, infant/child (3 – 15 kg) toe, child (15 – 50 kg) finger,
cable length: 1.6 m, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 5 pcs
P259
COTTONY Tape for fixing disposable SpO2 Probes, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 20 pcs
92
Transmitters › SpO2 Measurement
www.nihonkohden.net
Disposable Multi-Site SpO₂ Probes 5 pcs/box - cable length: 2.0 m
Facts
The probe P205A is specially designed for extremely sensitive skin. It uses soft and breathable sponge for the attachment tape. The attachment tape
and sensor parts are separate. You can select from two sizes of attachment tape: P260A or P260B. When using the probes without those tapes for
prematures, SpO2 measurement may be incorrect and the skin at the attachment site may be irritated.
The attachment tape consists of two parts: adhesive and non-adhesive part. To get best fit, place the tape at the required attachment site. Wrap
the sponge attachment tape (non-adhesive part) around the attachment site. Confirm that the light emitters and detector face to each other before
removing backing paper of the adhesive part. Then continue wrapping to fasten the probe. Replace the sponge attachment tapes every 24 hours.
Supply Code Model
Description
P205A
SpO2 Multi-Site Probe, cable length: 2.0 m, neonate (< 3 kg) instep, child/adult (> 3 kg)
finger/toe, fixed with P260A/B or for P256, single-patient use
For current products: all BSM/PVM
Packing unit: 5 pcs
TL-260T
P260A
Sponge Attachment Tape Type S for P205A, premature (< 1 kg) instep, neonate/infant
(> 3 kg) finger/toe, disposable,
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
P260B
Sponge Attachment Tape Type L for P205A, neonate (> 3 kg) instep, disposable
For current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PG
Packing unit: 24 pcs
Handling of the probe affects measurement accuracy and patient safety
For the proper placement of the probe on the finger, it is advisable that the light emitters and detector are placed just opposite to each
other. When using a clip-finger probe, it is necessary to ensure that the probe covers the finger properly, otherwise some portion of the
light never passes through the body tissues and may reach the light-receiving part directly, leading to incorrect measurement results.
The more distant the light-emitters and detector gets, the weaker the transmitted light intensity becomes. Additionally, a thinner body part
tends to have small amount of blood, wich makes it difficult to extract the arterial blood signal component. The most suitable thickness
of the probe site is about 10 mm.
Too loose probes may interfere with alignment of LEDs and detector, come off easily by body movement, cause larger motion artifacts or
be effected by venous pulse.
Too tight probes may cause venous pulsation, cause skin injuries such as burn and necrosis or unstable measurement because of a lower
pulsatile signal.
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
93
www.nihonkohden.net
NIBP Measurement (Non-Invasvie Blood Pressure)
Blood pressure (BP) is the pressure exerted by circulating blood against the artery walls. During each heartbeat, the blood
pressure varies between a maximum (systolic) and a minimum (diastolic) pressure. The variation indicates the condition
of the pumping function of the heart as an important vital sign.
A non-invasive indirect method to measure the blood pressure is the oscillometric blood pressure measurement. This method is using an inflated blood pressure cuff which is applied to the patient’s arm or thigh. The blood pressure is detected
by partial occlusion of the artery by the cuff. The so called Korotkoff sound is generated by the distension of the arterial
wall with each cardiac impulse. Systolic and diastolic blood pressures are determined by an algorithmic interpretation of
the device based on the mean arterial pressure and changing amplitude of the Korotkoff sounds.
For a proper non-invasive measurement it is important to use the correct cuff size due to the fact that a too small cuff will
lead to faulty high pressure, while a too large will lead to wrong low pressure readings.
Please contact us for an individual offer based on your annual volume! Use the possibility of call orders!
94
Transmitters › NIBP Measurement
www.nihonkohden.net
NIBP Measurement with ZS/ZM-940PG
Reusable NIBP Cuffs for attaching transmitter to the arm
Supply Code Model
Description
S938B
YP-943P
Adult NIBP Cuff, width: 13 cm, arm-circumference: 21 to 30 cm, latex-free, reusable
For current products: ZS/ZM-940PG
Packing unit: 1 pcs
S938C
S938C
Adult NIBP Cuff, width: 15 cm, arm-circumference: 26 to 36 cm, latex-free, reusable
For current products: ZS/ZM-940PG
Packing unit: 1 pcs
NIBP Air Hoses for ZS/ZM-940PG
Supply Code Model
Description
S903
NIBP Air-Hose Extension Cable, cable length: 1.5 m
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
YN-990P
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
95
Transmitters › NIBP Measurement
www.nihonkohden.net
Reusable Standard NIBP Cuffs
Supply Code Model
Description
S943A
YP-960T
Infant NIBP Cuff, width: 5 cm, arm-circumference: 8 to 13 cm, latex-free, reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S943B
YP-961T
Child NIBP Cuff, width: 7 cm, arm-circumference: 12 to 18 cm, latex-free, reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S943C
YP-962T
Child NIBP Cuff, width: 10 cm, arm-circumference: 15 to 23 cm, latex-free, reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S944B
YP-963T
Adult NIBP Cuff, width: 13 cm, arm-circumference: 21 to 30 cm, latex-free, reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S944C
YP-964T
Adult NIBP Cuff, width: 15 cm, arm-circumference: 26 to 36 cm, latex-free, reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
96
Transmitters › NIBP Measurement
www.nihonkohden.net
Reusable YAWARA NIBP Cuffs
Facts
NIHON KOHDEN YAWARA-CUFF means soft and strong cuff. The name YAWARA is based on the Japanese words YAWARAkai = Soft (in Japanese),
YAWARA Judo (in Japanese) and Judo means Strong.
The softness of the cuff is realized in the soft and smooth polyester with a buffer sheet over the skin contact area reducing the risk of wrinkling the
patient’s skin and the risk of internal bleeding. The buffer sheet also evenly distributes the air pressure to prevent too much pressure on one point.
The strongness is realized both in the nylon cable in the air tube preventing incidents caused by tube kinking and the durable bladder material
(polyurethane).
In addition to this the YAWARA-CUFF is characterized by easy handling. A wide opening lets you easily remove and insert the bladder for cleaning. The cloth is
water-resistant, so you can wipe it without any problem. The watertight connector cap prevents fluid from getting into the air tube while cleaning and is provided with each cuff. An outside printed cuff scale behind the arm helps you quickly check if the cuff has the right size for the patient. The upper arm should be
between the minimum and maximum scale.
Supply Code Model
Description
S949A
YP-702T
Child NIBP YAWARA Cuff, width: 10 cm, arm-circumference: 15 to 23 cm, latex-free,
reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
S949B
YP-703T
Adult NIBP YAWARA Cuff, width: 13 cm, arm-circumference: 21 to 30 cm, latex-free,
reusable
For current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PG
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
97
Transmitters › NIBP Measurement
www.nihonkohden.net
Disposable NIBP Cuffs for Infants & Children
Supply Code
Description
NKD-S947A
Infant NIBP Cuff, width: 6 cm, arm-circumference: 8 to 14 cm, color: blue, latex-free,
disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947B
Child NIBP Cuff, width: 8 cm, arm-circumference: 13 to 20 cm, color: green, latex-free,
disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
Disposable NIBP Cuffs for Adults
Supply Code
Description
NKD-S947C
Small Adult NIBP Cuff, width: 10 cm, arm-circumference: 18 to 26 cm, color: orange,
latex-free, disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947D
Adult NIBP Cuff, width: 14 cm, arm-circumference: 26 to 35 cm, color: blue, latex-free,
disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947E
Adult Long NIBP Cuff, width: 15 cm, arm-circumference: 29 to 38 cm, color: red,
latex-free, disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947F
Adult Large NIBP Cuff, width: 7 cm, arm-circumference: 32 to 42 cm, color: green,
latex-free, disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947G
Large Adult Long NIBP Cuff, width: 18 cm, arm-circumference: 35 to 44 cm,
color: orange, latex-free, disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
NKD-S947H
Adult Thigh NIBP Cuff, width: 20 cm, thigh-circumference: 42 to 50 cm, color: blue,
latex-free, disposable
For current products: all BSM/PVM/TEC-77/8300, ZS/ZM-940PG
Packing unit: 20 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
98
www.nihonkohden.net
Straps
&
Bags, Straps & Holder for Transmitters
99
Transmitters › Bags, Straps & Holder
www.nihonkohden.net
Bags, Straps & Holder for Transmitters
Supply Code Model
Description
NKD-TC2016
Transmitter Transport Bag, reusable
For current products: ZS-910/920PG
Packing unit: 1 pcs
YP-960T
NKD-TC2017
Transmitter Transport Bag, reusable
For current products: ZS/ZM-930PG
Packing unit: 1 pcs
NKD-TC2018
Disposable Transmitter Bag, size: 25 cm x 15 cm, band length: 1.2 m, material recto:
plastic wrap, material verso: white fleece 100 mµ, velcro fastener
For current products: all NK Transmitters
Packing unit: 10 pcs
Y233
Strap for Transmitter
For current products: ZS-910/920/930/530PG
Packing unit: 1 pcs
Y234
YS-076P6
Holder for ZB- and ZS-900PG Transmitters
Packing unit: 1 pcs
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
100
Transmitters › Bags, Straps & Holder
Supply Code
Description
Y236
Strap for Transmitter
For current products: ZS/ZM-940PG
Packing unit: 1 pcs
Y237
Transmitter Bag, requires Y032B & Y032C and S903
For current products: ZS/ZM-940PG
Packing unit: 1 pcs
Y032B
Shoulder Belt for Y237
For current products: ZS/ZM-940PG
Packing unit: 1 pcs
Y032C
Waist Belt for Y237
For current products: ZS/ZM-940PG
Packing unit: 1 pcs
www.nihonkohden.net
Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories!
Reusable accessories are intended for repeated patient use on different patients during different examinations. Please make sure to clean reusable accessories after each patient or
between different applications to prevent or reduce the risk of cross infections!
101
www.nihonkohden.net
www.nihonkohden.net
ACCESSORY ORDER FORM
For your convenience we have a printable order form so that you can fax in your order directly or mail/e-mail it to us.
Please make sure to fill out all the information requested below!
Hospital/Practice
Contact Person
Department
Customer Code
Address
ZIP
City
Phone
Fax
E-Mail
ACCESSORY ORDER FORM
3 Days
2 Days
Monthly, please contact me for more details
Other
Standard
Supply Code
Description
Send in your order today!
Required Quantity
For Germany, Auastria, Switzerland and Benelux
Fax: +49 (0) 33203/573-19, E-Mail: [email protected]
For Spain and Portugal
Fax: +34 91 300 46 76, E-Mail: [email protected]
For United Kingdom
Fax: +44 (0) 20 83 90 46 75, E-Mail: [email protected]
Overnight
Price each in EUR / £
Price Total in EUR / £
For France
Fax: +33 (0) 1 49 08 93 32, E-Mail: [email protected]
For Italy
Fax: +39 (0)35-232546, E-Mail: [email protected]
For all other European Countries, Russia, Turkey and Israel
Fax: +49 (0) 6003/827-599, E-Mail: [email protected]
102
Index as per Supply Code
www.nihonkohden.net
Index as per Supply Code
Supply Code
page
Supply Code
page
Supply Code
page
Supply Code
page
804
42
K912
12, 79
NKD-009818
44
NKD-ED/93528
60
6114-915735
48
K915
12, 79
NKD-009822
45
NKD-G001099
70
6124-039432
12
K921
13
NKD-5203201
56
NKD-G010104
70
6144-900614A
47, 48
K922
12
NKD-5750005
70
NKD-G016094
70
A226
73
K931
18
NKD-5750019
71
NKD-IBP/LOGICAL
56
A721
73
K935
29
NKD-5750027
71
NKD-IBP/LOGICAL2
56
A810
73
K936
29
NKD-5750031
70
NKD-IBP/LOGICAL3
56
K937
29
NKD-79950001
70
NKD-IBP/LOGICAL4
57
NKD-TOF/
Connection Cable
69, 70
K941
53
NKD-79950152
71
NKD-IBP/TRANSPAC
57
F020
65
K951
55
NKD-79950207
71
NKD-IBP/TRANSTAR
57
F509
65
K952
55, 58
NKD-79950209
71
NKD-IBP/UTAH
57
F510
65
K957
55
NKD-79950213
71
NKD-IBP/UTAH2
57
G203
15, 81
K961
37
NKD-79950217
71
NKD-L572
69
G204
15, 81
K962
60
NKD-8290285
49
NKD-L936
75
G207
15, 81
K974
75
NKD-936979
49
NKD-N PREP
65
G210C
16, 69, 82
K975
75
NKD-A723
73
NKD-O2-CAP
43
G210D
15, 81
K977
49
NKD-AR205
65
NKD-P240A
37
G236
15, 82
K978
49
NKD-BDP178NK1
56
NKD-P241A
37
G250
15, 82
K981
40
NKD-BDP178NK4
56
NKD-P242B
37
G271A
16
K984
42
NKD-BDPT-1078
56
NKD-P249
37
G272A
16
K987
41
NKD-BN100
66
NKD-Power Cable 1,5 75
G272B
16
L301
18
NKD-BN101
66
NKD-Power Cable 2,0 75
G272C
16
L302
18
NKD-BN106
66
NKD-S947A
35, 97
G278A
16
L311
18
NKD-BN107
66
NKD-S947B
35, 97
G300A
16
L461
63
NKD-BN108
66
NKD-S947C
35, 97
H471
63
L462
64
NKD-BN109
66
NKD-S947D
35, 97
H472
63
L901
55
NKD-BN111
67
NKD-S947E
35, 97
H503B
64
L902
55
NKD-BN112
67
NKD-S947F
35, 97
H527
64
NKD-006324
44
NKD-BN113
67
NKD-S947G
35, 97
H537A
64
NKD-007266
44
NKD-BN114
67
NKD-S947H
35, 97
JP-911P
58
NKD-007269
45
NKD-BN115
67
NKD-S948A
34
K120
12, 79
NKD-008177
45
NKD-BN500
67
NKD-S948B
34
K461
63
NKD-008178
45
NKD-BN505
67
NKD-S948C
34
K901
13
NKD-008179
45
NKD-CALGAS
47
NKD-S948D
34
K910A
12, 79
NKD-008180
45
NKD-CO2GAS
43
NKD-S948E
34
K911
12, 79
NKD-008181
45
NKD-EC2
65
NKD-SP4045
60
103
Index as per Supply Code
www.nihonkohden.net
Index as per Supply Code
Supply Code
page
Supply Code
page
Supply Code
page
Supply Code
page
NKD-SP4572
60
P204E
26
R804
42
Y032C
100
NKD-SP5045
60
P204F
26, 91
R805
41
Y075
75
NKD-SP5107H
60
P204G
26, 91
R806
41
Y094A
18
NKD-SP5107H-IS
61
P205A
23, 27, 88, 92
S901
31
Y233
99
NKD-TC2016
99
P225F
21, 86
S902
31
Y234
99
NKD-TC2017
99
P225G
21, 86
S903
31, 94
Y236
100
NKD-TC2018
99
P225H
21, 86
S904
31
Y237
100
P228A
25, 90
S905
31
P228B
26, 91
S938B
94
P229A
25, 90
S938C
94
NKD-TEMPHEARTS4009
37
NKD-TEMPHEARTS
4012
37
P229B
26, 91
S943A
32, 96
NKD-V915A
47
P256
23, 88
S943B
32, 95
NKD-V915B
47
P259
25, 26, 90, 91
S943C
32, 95
NKD-V916A
47
P260A
27, 92
S944B
32, 95
NKD-V916B
47
P260B
27, 92
S944C
32, 95
NKD-V917A
47
P263
22, 87
S944D
32
NKD-V917B
48
P267
22, 87
S949A
33, 96
NKD-V917C
48
P310C
22, 87
S949B
33, 96
NKD-V917D
48
P311C
22, 87
SB-201VK
74
NKD-V918
49
P901
53
SB-610RK
74
NKD-V919
49
P902
53
SP-4035-1
61
NKD-VENTIL3
43
P903
40
V901
44, 48
NKD-XS04620
44
P907
42
V903F
48
NKD-XS04624
44
P909
41
V910
41
P203A
23, 88
P911
53
V911
53
P203B
23, 88
P912
51
V912
53
P203C
24, 89
P913
51
V920A
49
P203D
24, 89
P914
51
V920B
49
P203E
24, 89, 91
P915
51
V921
42
P203F
24, 89
P922A
40
V922
43
P203G
24, 89
P923
42
V923
43
P203H
24, 89
P924
41
X060
74
P204A
24, 89
QF-909P
69
X062
74
P204B
25, 90
R801
40
X072
74
P204C
25, 90
R802
43
X076
74
P204D
25, 90
R803
43
Y011
75
104
Index as per Model Code
www.nihonkohden.net
Index as per Model Code
Model Code
page
Model Code
page
Model Code
page
Model Code
page
74705
53
JG-970P
41
TL-201T
21, 86
YJ-920P
75
110774
53
JL-302T
18
TL-201T1
21, 86
YN-900P
31
404617
75
JL-500P2
18
TL-220T
21, 86
YN-901P
31
618877
48
JL-630P
29
TL-260T
23, 27, 88, 92
YN-920P
31
5750006
70
JL-631P
29
TL-271T
23, 24, 88, 89
YN-921P
31
5750011
70
JL-650P
29
TL-271T3
24, 26, 89, 91
YN-990P
31, 94
5750014
70
JL-900P
18
TL-272T
23, 25 , 88, 90
YP-702T
33, 96
8290286
49
JO-900P
53
TL-272T3
24, 26, 89, 91
YP-703T
33, 96
7995001
70
JP-900P
55
TL-273T
24, 25, 89, 90
YP-960T
32, 95, 99
79950152
71
JP-910P
55, 58
TL-273T3
24, 26, 89, 90
YP-961T
32, 95
79950154
70
JP-920P
55
TL-274T
24, 25, 89, 90
YP-962T
32, 95
79950207
71
JP-960P
55
TL-274T3
24, 26, 89, 91
YP-963T
32, 95
79950208
71
JT-900P
37
TL-630T3
22, 87
YP-964T
32, 95
79950209
71
JT-950P
60
TL-631T3
22, 87
YP-965T
32
79950213
71
L-150
15, 81
TR-900P
53
YS-076P5
75
79950217
71
L-150X
15, 81
V-040M4
16
YS-085P6
74
6143-012434
23, 88
M-150
15, 82
V-06OM6
16
YS-093P2
22, 87
BE-910P
63
N-03IS3
16
V-09IO3
16
YS-094P0
51
BE-920P
63
NA-0003
12
V-09OM3
16
YS-094P0
51
BE-930P
63
NE-114A
64
V-120S3
16
YSI-401
37
BJ-900P
13
NE-136A
64
YF-120P
51
YSI-402
37
BR-903P
12, 79
NE-224S
64
YG-001P
53
YSI-409B
37
BR-906P
12, 79
NKB-101
74
YG-101T
40
YZ-0019
65
BR-913P
12, 79
QW60-2
73
YG-111T
42
YZ-0254
75
BR-916P
12, 79
SB-201P
74
YG-120T
42
Z-181JE
65
C-150
15, 81
TF-120P
51
YG-121T
43
Z-401CE
65
F-150M
15, 81
TF-910P
51
YG-122T
43
NA-003
12, 79
F-150S
16, 69, 82
TR-910P
53
YG-201T
43
JP-912P
55
G001034
70
TG-101T
40
YG-202T
43
5750027
71
J-150
15, 82
TG-121T
42
YG-211T
41
FQS50-2-100
73
JC-024P
18
TG-221T
41
YG-213T
41
YG-620P
49
JC-025P
18
TG-900P
40
YG-270P
41
FQS50-2-100
73
JC-900P
13
TG-920P
42
YG-620P
49
FQW50-2-100
73
JC-906P
12
TG-970P
41
YG-621P
49
YP-943P
94
JE-905P
63
TL-051S
25, 90
YG-920P
44, 48
S938C
94
JE-906P
64
TL-052S
26, 91
YJ-600P
49
JG-900P
40
TL-061S
25, 90
YJ-601P
49
JG-920P
42
TL-062S
26, 91
YJ-910P
75
For Germany, Austria, Switzerland and Benelux
NIHON KOHDEN EUROPE GmbH, Vertrieb Deutschland
Albert-Einstein-Ring 9, 14532 Kleinmachnow, Deutschland
Fax: +49 (0) 33203/573-19, E-Mail: [email protected]
For Spain and Portugal
NIHON KOHDEN IBERICA S.L.
C/Ulises, 75A, 28043 Madrid, Spain
Fax: +34 91 300 46 76, E-Mail: [email protected]
For United Kingdom
NIHON KOHDEN UNITED KINGDOM Ltd.
Tolworth Tower – 19th Floor, Ewell Road, Surbiton,
Surrey KT6 7EL, United Kingdom
Fax: +44 (0) 20 83 90 46 75, E-Mail: [email protected]
NKE-BRZ-PMSK/A
For France
NIHON KOHDEN FRANCE SARL
8, rue François Delage, 94230 Cachan, France
Fax: +33 (0) 1 49 08 93 32, E-Mail: [email protected]
For Italy
NIHON KOHDEN ITALIA S.r.l.
Via Fratelli Bronzetti, 28, 24124 Bergamo, Italy
Fax: +39 (0) 35-232546, E-Mail: [email protected]
For all other European Countries, Russia, Turkey and Israel
NIHON KOHDEN EUROPE GmbH
Raiffeisenstraße 10, 61191 Rosbach v. d. H., Germany
Fax: +49 (0) 6003/827-599, E-Mail: [email protected]