TRICAD MS Releasenotes

Transcription

TRICAD MS Releasenotes
Daimler AG
Release Notes for TRICAD MS 2016.0
Introduction
Cover sheet
1. Introduction
1.1 Cover sheet
Release Notes for TRICAD MS 2016.0
for MicroStation V8i
Release May 2016
Status:
Author:
Status 02/05/2016
02/05/2016
VenturisIT GmbH
Page 1 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Introduction
Table of Contents
1.2 Table of Contents
Inhalt
1. Introduction................................................................................................................ 1
1.1
1.2
Cover sheet.............................................................................................................................. 1
Table of Contents ................................................................................................................... 2
2 Software Functionalities/Bug fixing TRICAD MS TGA Modules ....................... 4
2.1
2.1.1
2.1.2
2.1.3
2.2
2.2.1
2.3
2.3.1
2.3.2
2.4
2.4.1
2.4.2
2.4.3
2.4.4
2.4.5
2.4.6
2.5
2.5.1
General .................................................................................................................................... 4
Tool Labelling Height dimension in metres ..................................................................................... 4
Technical data - delete TRICAD MS TAGS .................................................................................... 5
New values for inserting Asymmetric Elbows ................................................................................. 6
TRICAD MS Heating ............................................................................................................ 7
Pumps with asymmetric outlet .......................................................................................................... 7
TRICAD MS Sanitary ........................................................................................................... 8
Straight screwed joints ...................................................................................................................... 8
New function: Connecting of gradient pipes + floor drains ............................................................. 9
TRICAD MS Ventilation ..................................................................................................... 16
New component Volume flow controller RN Ex ........................................................................... 16
Insulation thickness selection extended .......................................................................................... 17
New outlets from Krantz................................................................................................................. 18
Particulate filters - air diffusers ...................................................................................................... 20
Particulate filter box........................................................................................................................ 29
Change of term from Penetration to Opening ................................................................................. 30
TRICAD MS Sprinkler ....................................................................................................... 31
K360 Sprinkler types EC-25 incorporated...................................................................................... 31
3 Software functionalities/bug fixing TRICAD MS Factory Planning modules .. 32
3.1
3.1.1
3.1.2
3.1.3
3.1.4
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.3
3.4
3.4.1
3.4.2
3.4.3
3.4.4
3.4.5
3.4.6
3.4.7
3.4.8
3.4.9
3.4.10
3.4.11
3.4.12
3.4.13
3.4.14
3.4.15
3.5
TRICAD MS equipment layout .......................................................................................... 32
Thickness with system wall is now adjusted .................................................................................. 32
Change cell colour of manipulators ................................................................................................ 33
Extension to pulldown menu to accommodate vessels and pumps ................................................ 34
Two new robot types ...................................................................................................................... 35
Trailer ................................................................................................................................... 36
Show trailer seating plates .............................................................................................................. 36
Place trailer storage compartment rack without vehicle ................................................................. 37
Define name and description for storage compartment rack .......................................................... 38
Trailer entry at the rear ................................................................................................................... 40
Conveyor systems for loading of machines ........................................................................ 41
Platforms and maintenance platforms ............................................................................... 44
Place stage on the clicked corner points ......................................................................................... 44
Place stage on the clicked shape ..................................................................................................... 45
Stages preview window .................................................................................................................. 46
Place stair ........................................................................................................................................ 48
Place ladder ..................................................................................................................................... 51
Place support ................................................................................................................................... 52
Placing flaps, openings in stage railings ......................................................................................... 53
Delete 3D stage elements ................................................................................................................ 54
Stages, stairs and ladders are rebuilt ............................................................................................... 55
Change stage and opening areas ..................................................................................................... 56
Check stage railings ........................................................................................................................ 57
Change stage using definition dialogue .......................................................................................... 58
Display stage data mask.................................................................................................................. 60
Display stair and ladder data masks ................................................................................................ 61
Define stages ................................................................................................................................... 62
Stage module ......................................................................................................................... 63
Status 02/05/2016
Page 2 of 82 pages
Daimler AG
3.5.1
3.6
3.6.1
Release Notes for TRICAD MS 2016.0
Introduction
Table of Contents
Maintenance stages generated by new functions, analogous to Layout Functions ......................... 63
Chip module.......................................................................................................................... 64
Storeys / Layers .............................................................................................................................. 64
4 Changes in DAIMLER_ENV TGA modules ........................................................ 65
4.1
4.1.1
4.1.2
4.2
4.2.1
4.3
4.3.1
TRICAD MS Electrical ....................................................................................................... 65
Cell selector without plan type differentiation................................................................................ 65
New lights ....................................................................................................................................... 65
TRICAD MS infrastructure module .................................................................................. 75
Materials corrected ......................................................................................................................... 75
TRICAD MS Sanitary ......................................................................................................... 76
Nom. diameters in SML material supplemented ............................................................................ 76
5 Changes to DAIMLER_ENV factory planning modules..................................... 77
5.1
5.1.1
5.1.2
5.1.3
5.1.4
5.1.5
5.1.6
5.2
5.2.1
TRICAD MS Module Layout.............................................................................................. 77
Cell selector extended ..................................................................................................................... 77
New function for creating stages has been integrated .................................................................... 77
New function for machine loading integrated into parametric conveyor systems .......................... 78
New settings for system walls from GEMAC ................................................................................ 79
New report on area designations ..................................................................................................... 80
Trailer parametrics adapted ............................................................................................................ 81
Qualitool................................................................................................................................ 82
New name assignment to file attributes .......................................................................................... 82
Status 02/05/2016
Page 3 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
General
2 Software Functionalities/Bug fixing TRICAD MS TGA
Modules
2.1 General
2.1.1 Tool Labelling Height dimension in metres
With the labelling, the height can be read out in metres, as well as
the number of places after the point.
Supplement the height variable ${UKK} with “m” for the units and “:2” for the
places after the point ${UKK:m:2}
Status 02/05/2016
Page 4 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
General
2.1.2 Technical data - delete TRICAD MS TAGS
Append technical data in the dialogue
These can now also be deleted.
Status 02/05/2016
Page 5 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
General
2.1.3 New values for inserting Asymmetric Elbows
The insertion ends are defined in the "einschub_" files.
Format of the "einschub_" files:
Meaning of the factor MC:
MC = 0
MC = 2
MC = 1
MC = 3
Value ASS, ASE:
This value is for an asymmetric elbow, i.e. elbow with plug-in ends and unequal leg lengths!
Status 02/05/2016
Page 6 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Heating
2.2 TRICAD MS Heating
2.2.1 Pumps with asymmetric outlet
Pumps from Grundfos have been included. The cell selector choice for pumps was completely taken over
and re-sorted.
Status 02/05/2016
Page 7 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Sanitary
2.3 TRICAD MS Sanitary
2.3.1 Straight screwed joints
Straight screwed joints taken over from Swagelok
Normal straight screwed joint
Status 02/05/2016
with DN 15 possible bored-through screwed joint
Page 8 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Sanitary
2.3.2 New function: Connecting of gradient pipes + floor drains
2.3.2.1 Connecting gradient pipes:
Connection with rotated T-piece without query:
Connection with rotated T-piece: Rotated (sanitary mode)
Connection with rotated T-piece: Vertical / not rotated outwards
Status 02/05/2016
Page 9 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Sanitary
Connection with rotated T-piece: Vertical / 45° / rotated outwards:
Status 02/05/2016
Page 10 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Sanitary
2.3.2.2 Connect vertical pipe to header
Status:
Without query:
Status 02/05/2016
Page 11 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Sanitary
With query:
Connection directly under 45° on header? No
Connection with rotated T-piece: Rotated (sanitary mode)
Connect pipe with 45° or (88/89/90) degree T-piece? 45°
Status 02/05/2016
Page 12 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Sanitary
2.3.2.3 Floor drains:
Status:
Assignment
Status 02/05/2016
Page 13 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Sanitary
Connected individually:
All connected…Any rotation of T-piece is automatically calculated.
Status 02/05/2016
Page 14 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Sanitary
Drain with side outlet:
Rotation outwards is automatically calculated:
Status 02/05/2016
Page 15 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4 TRICAD MS Ventilation
2.4.1 New component Volume flow controller RN Ex
A KVS RN-Ex volume flow controller has been included in the components.
Status 02/05/2016
Page 16 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.2 Insulation thickness selection extended
Lack of insulation thicknesses, collisions caused by outer dimensions drawn too small, Necessary
parameters have been extended:
Status 02/05/2016
Page 17 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.3 New outlets from Krantz
2.4.3.1 Radial outlets of diverse types with and w/o connections
The selection of radial outlets from the manufacturer Krantz has been rounded out (highlighted were
available). In this, the subdivision has also been arranged more clearly.
Representation of the new types:
Status 02/05/2016
Page 18 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.3.2 Radial outlets that cannot be illustrated using XML
Adjustable radial outlet with core pipe RA-V2, radial outlet RA-N2 connection type F
2.4.3.3 Variable diffuser with core pipe
Status 02/05/2016
Page 19 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.4 Particulate filters - air diffusers
The particulate filters have been revised. Ceiling air diffuser types F640, F650, F654, F655, F656, F59,
F660 can be selected, also wall diffuser F670.
Type designations in the ordering key:
were not considered
Status 02/05/2016
Page 20 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.4.1 Types F64*
The nozzle form is the third digit in the number here.
Status 02/05/2016
Page 21 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.4.2 Types F650
Status 02/05/2016
Page 22 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.4.3 Types F654
Status 02/05/2016
Page 23 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.4.4 Types F655
Status 02/05/2016
Page 24 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.4.5 Types F656
Status 02/05/2016
Page 25 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.4.6 Types F659
Status 02/05/2016
Page 26 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.4.7 Types F660
The nozzle form here is here is the third digit in the number.
Status 02/05/2016
Page 27 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.4.8 Wall diffuser Type F670
Status 02/05/2016
Page 28 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.5 Particulate filter box
New component from the Schako company, particulate filter box FKU in RE design, version DQJA-SQ.
Status 02/05/2016
Page 29 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Ventilation
2.4.6 Change of term from Penetration to Opening
The term penetration has been changed to Opening.
Status 02/05/2016
Page 30 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software Functionalities/Bug fixing TRICAD MS TGA Modules
TRICAD MS Sprinkler
2.5 TRICAD MS Sprinkler
2.5.1 K360 Sprinkler types EC-25 incorporated
The selection of stationary sprinklers has been extended by adding Type E-25 from Tyko.
Status 02/05/2016
Page 31 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
TRICAD MS equipment layout
3 Software functionalities/bug fixing TRICAD MS Factory
Planning modules
3.1 TRICAD MS equipment layout
3.1.1 Thickness with system wall is now adjusted
If a new system wall is created from an existing one, the thickness of the wall is now taken over.
Status 02/05/2016
Page 32 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
TRICAD MS equipment layout
3.1.2 Change cell colour of manipulators
The button at the manipulators for changing cell colour is now stored.
Status 02/05/2016
Page 33 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
TRICAD MS equipment layout
3.1.3 Extension to pulldown menu to accommodate vessels and pumps
The pulldown menu Electric, Media has been extended to take the items vessels and pumps.
Status 02/05/2016
Page 34 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
TRICAD MS equipment layout
3.1.4 Two new robot types
Two new robots to choose from: Kuka KR150 R3100 Prime and ABB IRB 5500
Status 02/05/2016
Page 35 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Trailer
3.2 Trailer
3.2.1 Show trailer seating plates
Rectangular plates can be shown at the trailer corners for taking up the load. If positioning assistance is
also available, the rectangular plates are aligned to this.
Extension to the definition dialogue:
2.
3.
1.
Extension to the data mask:
Status 02/05/2016
Page 36 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Trailer
3.2.2 Place trailer storage compartment rack without vehicle
With trailers that have a storage compartment rack mount, this mount can also be placed as a single object
in the drawing.
The storage compartment rack has its own data mask and can be adapted (parametric cell) by changing
the data mask values.
Status 02/05/2016
Page 37 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Trailer
3.2.3 Define name and description for storage compartment rack
If storage compartment racks are placed as a separate cell without vehicle, the name and description
defined here are transferred to the storage compartment rack data mask.
Status 02/05/2016
Page 38 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Trailer
Example:
Placing of a trailer with storage compartment rack - switch ".. without placing vehicle" switched on
The storage compartment rack cell receives the predefined texts as name and designation attribute.
Status 02/05/2016
Page 39 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Trailer
3.2.4 Trailer entry at the rear
Trailer entry from the rear has been added to the existing left and/or right entries.
Status 02/05/2016
Page 40 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Conveyor systems for loading of machines
3.3 Conveyor systems for loading of machines
The
button of the machine design toolbox
starts the conveyor system toolbox.
Conveyor systems are used to transport components to and from machines. They consist of straight
elements, bends, entry/exit transfer, and redirecting elements. In addition to adjustable feet, catchment
trays and drive motors can be placed; direction arrows are shown on straight sections. The interference
space is displayed as an option above the conveyor system.
All components are created parametrically (... no cell libraries are used).
Status 02/05/2016
Page 41 of 82 pages
Daimler AG
Status 02/05/2016
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Conveyor systems for loading of machines
Page 42 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Conveyor systems for loading of machines
The toolbox makes the following functions available:
Define conveyor system layout, click corner point
Define conveyor system layout, click polyline
Place bend


Place redirection (4 construction forms available)
Place exit transfer (2 construction forms available)
Place adjustable feet
Place drive
Place or change catchment tray (place optional additional adjustable feet)
Shorten or lengthen conveyor
Connect conveyors across corners
Reverse directional arrows
Reconstruct conveyor system
Change conveyor system
Define conveyor system
Predefined settings for all elements of the conveyor system can be selected in the toolbox:
All parameters and graphics properties are defined in a conveyor system XML file.
Status 02/05/2016
Page 43 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4 Platforms and maintenance platforms
3.4.1 Place stage on the clicked corner points
The
button of the "Create stage" toolbox
opens the "Create stage, click corner points" dialogue.
Status 02/05/2016
Page 44 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.2 Place stage on the clicked shape
The
button of the "Create stage" toolbox
Status 02/05/2016
Page 45 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
Stage polygons
All polygons created by MicroStation (shapes, ComplexShapes, ellipses) can be used as stage polygons.
If a simple shape which contains polygon areas or circles is clicked, the program queries at each
3.4.3 Stages preview window
The
icon of the stages toolbox
opens a preview window in which the currently set stage is shown:
Status 02/05/2016
Page 46 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
The size of the window can be changed. Pressing the
Status 02/05/2016
button again closes the preview window.
Page 47 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.4 Place stair
The
button of the stage toolbox
opens the stair-placing dialogue:
The stair is fixed to the clicked-on endpoint. The direction is defined by clicking a second point.
Place stair
The program places the stair at the nearest stage edge point.
Status 02/05/2016
Page 48 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
Any height can be defined. The program then searches for a suitable stair construction. A guideline is 18
steps per flight. The form of construction can be changed at any time
There are 1, 2 and 3-flight stairs available
Status 02/05/2016
Page 49 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
Connect storeys by stairs
The stair leading to the stage (see "Set stair at stage") and beyond can also be connected to more than one
storey by external stairs.
Status 02/05/2016
Page 50 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.5 Place ladder
The
button of the stage toolbox
opens the ladder-placing dialogue:
Ladders can be set onto existing stages. The stage railing is automatically split when doing this.
If no stage is found at the clicked-on point, the ladder can also be placed as free-standing in the model.
Status 02/05/2016
Page 51 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.6 Place support
The
button of the stage toolbox
opens the support placing dialogue:
Status 02/05/2016
Page 52 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.7 Placing flaps, openings in stage railings
The
button of the stage toolbox
opens the "Place doors, built-in elements" dialogue
All buttons are described in the chapter "Set elements, doors in railings".
Status 02/05/2016
Page 53 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.8 Delete 3D stage elements
The
button of "Display/change stage data" toolbox
prompts the clicking of any 3D stage element (edge profile, floor profile, support, grid or railing). The
program searches through all 3D elements of the stage cell and then deletes all 3D elements belonging to
the same stage.
Note:
If a complete stage is copied, the link (2D stage cell to all 3D cells) is lost. See also "Stage cell" chapter.
The 3D elements cannot therefore be deleted. The following message appears:
A rebuilding of the copied stage must now be performed only once. The
for this.
Status 02/05/2016
Page 54 of 82 pages
function "Rebuild stages and stairs" is available
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.9 Stages, stairs and ladders are rebuilt
The
button of "Display/change stage data" toolbox
deletes 3D stages and 3D stair elements and then rebuilds these. For this, the 2D stage and 2D stair cells
are used as building instructions.
Status 02/05/2016
Page 55 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.10 Change stage and opening areas
The
button of "Display/change stage data" toolbox
enables simple changing of stages and openings. The following dialogue mask is opened:
The program automatically searches for the nearest edge or opening point.
Click the corner point of a stage edge or of an opening and delete.
Example:
The clicked opening point has been removed, the stage rebuilt.
Status 02/05/2016
Page 56 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.11 Check stage railings
The
button of "Display/change stage data" toolbox
prompts the clicking of any 3D stage element. The program then checks whether all railing sections of the
associated stage at the exits to stairs, ladders, built-in elements and possibly also through-going supports
are correctly interrupted.
The stage railings are automatically interrupted during the placing of stairs, ladders and built-in
components. This function is only needed when stairs, ladders etc. are moved or copied using
MicroStation.
Example:
A stair has been deleted, the gap in the stage railings must
now be closed.
The railings are again closed after the
"Check railings" function
performed.
Status 02/05/2016
has been
Page 57 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.12 Change stage using definition dialogue
The
button of "Display/change stage data" toolbox
starts the function "Change stage using definition dialogue".
After clicking the stage to be modified, all stage parameters are read in from the drawing and displayed in
"Define stage".
(Note: The stage information button
function is available for quick changes to the essential stage
parameters. All stage parameters can be modified using the Change Function definition dialogue).
Status 02/05/2016
Page 58 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
The current settings are stored by entering a data point. The function is ended with Reset (right mouse
button) and the clicked-on stage remains unchanged.
Example:
Change stage floor covering parameters, colours etc... and click data point (left mouse button)
Status 02/05/2016
Page 59 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.13 Display stage data mask
The
button of "Display/change stage data" toolbox
prompts the clicking of a stage element. The data mask of the steel stage is then displayed.
It is also possible to set whether the stage shape element (that the TRICAD-MS data mask possesses as a
linkage) is to be shown flashing.
All changes to the data mask
are taken over into the current stage by
pressing "OK"
.
Status 02/05/2016
Page 60 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.14 Display stair and ladder data masks
The
button of "Display/change stage data" toolbox
prompts the clicking of a stair or ladder element. The data mask of the stair or ladder is then displayed.
It is also possible to set whether the
stair element or ladder-shape element is to be shown as flashing.
Changes in the data mask are accepted
into the current stair by pressing "OK"
.
Status 02/05/2016
Page 61 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Platforms and maintenance platforms
3.4.15 Define stages
The
button of the stage toolbox
opens the Define stage dialogue:
Status 02/05/2016
Page 62 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Stage module
3.5 Stage module
3.5.1 Maintenance stages generated by new functions, analogous to Layout Functions
The
icon of the stages module toolbox
starts the "Create steel stages, stairs, ladders" toolbox.
For this, the equipment layout program triLay8i is automatically activated. As long as this steel stages
toolbox is open, a second instance of the equipment layout program cannot be started.
Status 02/05/2016
Page 63 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Software functionalities/bug fixing TRICAD MS Factory Planning modules
Chip module
3.6 Chip module
3.6.1 Storeys / Layers
Adapted for the English environment:
The “lagen” or “lagen_e” file is searched for at env\db\spaene:
If no "lagen" file is found at \env\db\spaene, a search is made at env\db\sani :
Status 02/05/2016
Page 64 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes in DAIMLER_ENV TGA modules
TRICAD MS Electrical
4 Changes in DAIMLER_ENV TGA modules
4.1 TRICAD MS Electrical
4.1.1 Cell selector without plan type differentiation
In the TRICAD MS setting files 3D Electrical for Daimler, the differentiation according to plan type in the cell selector has
been removed.
4.1.2 New lights
4.1.2.1 Waldmann
Status 02/05/2016
Page 65 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes in DAIMLER_ENV TGA modules
TRICAD MS Electrical
4.1.2.2 Regent
Status 02/05/2016
Page 66 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes in DAIMLER_ENV TGA modules
TRICAD MS Electrical
4.1.2.3 Tulux
Status 02/05/2016
Page 67 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes in DAIMLER_ENV TGA modules
TRICAD MS Electrical
4.1.2.4 ZUMTOBEL
Status 02/05/2016
Page 68 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes in DAIMLER_ENV TGA modules
TRICAD MS Electrical
4.1.2.5 TRILUX
Status 02/05/2016
Page 69 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes in DAIMLER_ENV TGA modules
TRICAD MS Electrical
4.1.2.6 CEAG
Status 02/05/2016
Page 70 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes in DAIMLER_ENV TGA modules
TRICAD MS Electrical
4.1.2.7 BEGA
Status 02/05/2016
Page 71 of 82 pages
Daimler AG
Status 02/05/2016
Release Notes for TRICAD MS 2016.0
Changes in DAIMLER_ENV TGA modules
TRICAD MS Electrical
Page 72 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes in DAIMLER_ENV TGA modules
TRICAD MS Electrical
4.1.2.8 Spectral
Status 02/05/2016
Page 73 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes in DAIMLER_ENV TGA modules
TRICAD MS Electrical
4.1.2.9 Ridi
Status 02/05/2016
Page 74 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes in DAIMLER_ENV TGA modules
TRICAD MS infrastructure module
4.2 TRICAD MS infrastructure module
4.2.1 Materials corrected
The materials for the pipelines in the infrastructure module were obsolete and could, in part, no longer
function. These have now been updated.
Status 02/05/2016
Page 75 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes in DAIMLER_ENV TGA modules
TRICAD MS Sanitary
4.3 TRICAD MS Sanitary
4.3.1 Nom. diameters in SML material supplemented
The SML pipe material has been extended by the nom. diameter DN 80.
Status 02/05/2016
Page 76 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes to DAIMLER_ENV factory planning modules
TRICAD MS Module Layout
5 Changes to DAIMLER_ENV factory planning modules
5.1 TRICAD MS Module Layout
5.1.1 Cell selector extended
The cell selector has been extended in some areas. Please set the filter “Release 05/2016" in the cell
selector for further details.
5.1.2 New function for creating stages has been integrated
New functions for placing simple stages have been adopted in the Daimler settings files of TRICAD MS
Layout.
Status 02/05/2016
Page 77 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes to DAIMLER_ENV factory planning modules
TRICAD MS Module Layout
5.1.3 New function for machine loading integrated into parametric conveyor systems
The new functions for placing parametric conveyor systems for machine loading have been adopted into
the Daimler settings files of TRICAD MS Layout.
Status 02/05/2016
Page 78 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes to DAIMLER_ENV factory planning modules
TRICAD MS Module Layout
5.1.4 New settings for system walls from GEMAC
Status 02/05/2016
Page 79 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes to DAIMLER_ENV factory planning modules
TRICAD MS Module Layout
5.1.5 New report on area designations
The lists in the settings files of TRICAD MS Layout have been extended by those from the area designation report.
Status 02/05/2016
Page 80 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes to DAIMLER_ENV factory planning modules
TRICAD MS Module Layout
5.1.6 Trailer parametrics adapted
The parametrics of the trailers have been adapted to the current software extensions.
Status 02/05/2016
Page 81 of 82 pages
Daimler AG
Release Notes for TRICAD MS 2016.0
Changes to DAIMLER_ENV factory planning modules
Qualitool
5.2 Qualitool
5.2.1 New name assignment to file attributes
Because of a changeover in file names in the FAPLIS Navigator, the automatic file-dependent rule
assignment has been converted from file name assignment to file attribute assignment.
The user does not see this in the program interface. To be able to use the function, work must be
performed with current DGN files from the administration system, from the current TRICAD MS version
and from the current Daimler ENV.
Status 02/05/2016
Page 82 of 82 pages