TRICAD MS Releasenotes
Transcription
TRICAD MS Releasenotes
Daimler AG Release Notes for TRICAD MS 2016.0 Introduction Cover sheet 1. Introduction 1.1 Cover sheet Release Notes for TRICAD MS 2016.0 for MicroStation V8i Release May 2016 Status: Author: Status 02/05/2016 02/05/2016 VenturisIT GmbH Page 1 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Introduction Table of Contents 1.2 Table of Contents Inhalt 1. Introduction................................................................................................................ 1 1.1 1.2 Cover sheet.............................................................................................................................. 1 Table of Contents ................................................................................................................... 2 2 Software Functionalities/Bug fixing TRICAD MS TGA Modules ....................... 4 2.1 2.1.1 2.1.2 2.1.3 2.2 2.2.1 2.3 2.3.1 2.3.2 2.4 2.4.1 2.4.2 2.4.3 2.4.4 2.4.5 2.4.6 2.5 2.5.1 General .................................................................................................................................... 4 Tool Labelling Height dimension in metres ..................................................................................... 4 Technical data - delete TRICAD MS TAGS .................................................................................... 5 New values for inserting Asymmetric Elbows ................................................................................. 6 TRICAD MS Heating ............................................................................................................ 7 Pumps with asymmetric outlet .......................................................................................................... 7 TRICAD MS Sanitary ........................................................................................................... 8 Straight screwed joints ...................................................................................................................... 8 New function: Connecting of gradient pipes + floor drains ............................................................. 9 TRICAD MS Ventilation ..................................................................................................... 16 New component Volume flow controller RN Ex ........................................................................... 16 Insulation thickness selection extended .......................................................................................... 17 New outlets from Krantz................................................................................................................. 18 Particulate filters - air diffusers ...................................................................................................... 20 Particulate filter box........................................................................................................................ 29 Change of term from Penetration to Opening ................................................................................. 30 TRICAD MS Sprinkler ....................................................................................................... 31 K360 Sprinkler types EC-25 incorporated...................................................................................... 31 3 Software functionalities/bug fixing TRICAD MS Factory Planning modules .. 32 3.1 3.1.1 3.1.2 3.1.3 3.1.4 3.2 3.2.1 3.2.2 3.2.3 3.2.4 3.3 3.4 3.4.1 3.4.2 3.4.3 3.4.4 3.4.5 3.4.6 3.4.7 3.4.8 3.4.9 3.4.10 3.4.11 3.4.12 3.4.13 3.4.14 3.4.15 3.5 TRICAD MS equipment layout .......................................................................................... 32 Thickness with system wall is now adjusted .................................................................................. 32 Change cell colour of manipulators ................................................................................................ 33 Extension to pulldown menu to accommodate vessels and pumps ................................................ 34 Two new robot types ...................................................................................................................... 35 Trailer ................................................................................................................................... 36 Show trailer seating plates .............................................................................................................. 36 Place trailer storage compartment rack without vehicle ................................................................. 37 Define name and description for storage compartment rack .......................................................... 38 Trailer entry at the rear ................................................................................................................... 40 Conveyor systems for loading of machines ........................................................................ 41 Platforms and maintenance platforms ............................................................................... 44 Place stage on the clicked corner points ......................................................................................... 44 Place stage on the clicked shape ..................................................................................................... 45 Stages preview window .................................................................................................................. 46 Place stair ........................................................................................................................................ 48 Place ladder ..................................................................................................................................... 51 Place support ................................................................................................................................... 52 Placing flaps, openings in stage railings ......................................................................................... 53 Delete 3D stage elements ................................................................................................................ 54 Stages, stairs and ladders are rebuilt ............................................................................................... 55 Change stage and opening areas ..................................................................................................... 56 Check stage railings ........................................................................................................................ 57 Change stage using definition dialogue .......................................................................................... 58 Display stage data mask.................................................................................................................. 60 Display stair and ladder data masks ................................................................................................ 61 Define stages ................................................................................................................................... 62 Stage module ......................................................................................................................... 63 Status 02/05/2016 Page 2 of 82 pages Daimler AG 3.5.1 3.6 3.6.1 Release Notes for TRICAD MS 2016.0 Introduction Table of Contents Maintenance stages generated by new functions, analogous to Layout Functions ......................... 63 Chip module.......................................................................................................................... 64 Storeys / Layers .............................................................................................................................. 64 4 Changes in DAIMLER_ENV TGA modules ........................................................ 65 4.1 4.1.1 4.1.2 4.2 4.2.1 4.3 4.3.1 TRICAD MS Electrical ....................................................................................................... 65 Cell selector without plan type differentiation................................................................................ 65 New lights ....................................................................................................................................... 65 TRICAD MS infrastructure module .................................................................................. 75 Materials corrected ......................................................................................................................... 75 TRICAD MS Sanitary ......................................................................................................... 76 Nom. diameters in SML material supplemented ............................................................................ 76 5 Changes to DAIMLER_ENV factory planning modules..................................... 77 5.1 5.1.1 5.1.2 5.1.3 5.1.4 5.1.5 5.1.6 5.2 5.2.1 TRICAD MS Module Layout.............................................................................................. 77 Cell selector extended ..................................................................................................................... 77 New function for creating stages has been integrated .................................................................... 77 New function for machine loading integrated into parametric conveyor systems .......................... 78 New settings for system walls from GEMAC ................................................................................ 79 New report on area designations ..................................................................................................... 80 Trailer parametrics adapted ............................................................................................................ 81 Qualitool................................................................................................................................ 82 New name assignment to file attributes .......................................................................................... 82 Status 02/05/2016 Page 3 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules General 2 Software Functionalities/Bug fixing TRICAD MS TGA Modules 2.1 General 2.1.1 Tool Labelling Height dimension in metres With the labelling, the height can be read out in metres, as well as the number of places after the point. Supplement the height variable ${UKK} with “m” for the units and “:2” for the places after the point ${UKK:m:2} Status 02/05/2016 Page 4 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules General 2.1.2 Technical data - delete TRICAD MS TAGS Append technical data in the dialogue These can now also be deleted. Status 02/05/2016 Page 5 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules General 2.1.3 New values for inserting Asymmetric Elbows The insertion ends are defined in the "einschub_" files. Format of the "einschub_" files: Meaning of the factor MC: MC = 0 MC = 2 MC = 1 MC = 3 Value ASS, ASE: This value is for an asymmetric elbow, i.e. elbow with plug-in ends and unequal leg lengths! Status 02/05/2016 Page 6 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Heating 2.2 TRICAD MS Heating 2.2.1 Pumps with asymmetric outlet Pumps from Grundfos have been included. The cell selector choice for pumps was completely taken over and re-sorted. Status 02/05/2016 Page 7 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Sanitary 2.3 TRICAD MS Sanitary 2.3.1 Straight screwed joints Straight screwed joints taken over from Swagelok Normal straight screwed joint Status 02/05/2016 with DN 15 possible bored-through screwed joint Page 8 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Sanitary 2.3.2 New function: Connecting of gradient pipes + floor drains 2.3.2.1 Connecting gradient pipes: Connection with rotated T-piece without query: Connection with rotated T-piece: Rotated (sanitary mode) Connection with rotated T-piece: Vertical / not rotated outwards Status 02/05/2016 Page 9 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Sanitary Connection with rotated T-piece: Vertical / 45° / rotated outwards: Status 02/05/2016 Page 10 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Sanitary 2.3.2.2 Connect vertical pipe to header Status: Without query: Status 02/05/2016 Page 11 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Sanitary With query: Connection directly under 45° on header? No Connection with rotated T-piece: Rotated (sanitary mode) Connect pipe with 45° or (88/89/90) degree T-piece? 45° Status 02/05/2016 Page 12 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Sanitary 2.3.2.3 Floor drains: Status: Assignment Status 02/05/2016 Page 13 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Sanitary Connected individually: All connected…Any rotation of T-piece is automatically calculated. Status 02/05/2016 Page 14 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Sanitary Drain with side outlet: Rotation outwards is automatically calculated: Status 02/05/2016 Page 15 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4 TRICAD MS Ventilation 2.4.1 New component Volume flow controller RN Ex A KVS RN-Ex volume flow controller has been included in the components. Status 02/05/2016 Page 16 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.2 Insulation thickness selection extended Lack of insulation thicknesses, collisions caused by outer dimensions drawn too small, Necessary parameters have been extended: Status 02/05/2016 Page 17 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.3 New outlets from Krantz 2.4.3.1 Radial outlets of diverse types with and w/o connections The selection of radial outlets from the manufacturer Krantz has been rounded out (highlighted were available). In this, the subdivision has also been arranged more clearly. Representation of the new types: Status 02/05/2016 Page 18 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.3.2 Radial outlets that cannot be illustrated using XML Adjustable radial outlet with core pipe RA-V2, radial outlet RA-N2 connection type F 2.4.3.3 Variable diffuser with core pipe Status 02/05/2016 Page 19 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.4 Particulate filters - air diffusers The particulate filters have been revised. Ceiling air diffuser types F640, F650, F654, F655, F656, F59, F660 can be selected, also wall diffuser F670. Type designations in the ordering key: were not considered Status 02/05/2016 Page 20 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.4.1 Types F64* The nozzle form is the third digit in the number here. Status 02/05/2016 Page 21 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.4.2 Types F650 Status 02/05/2016 Page 22 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.4.3 Types F654 Status 02/05/2016 Page 23 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.4.4 Types F655 Status 02/05/2016 Page 24 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.4.5 Types F656 Status 02/05/2016 Page 25 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.4.6 Types F659 Status 02/05/2016 Page 26 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.4.7 Types F660 The nozzle form here is here is the third digit in the number. Status 02/05/2016 Page 27 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.4.8 Wall diffuser Type F670 Status 02/05/2016 Page 28 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.5 Particulate filter box New component from the Schako company, particulate filter box FKU in RE design, version DQJA-SQ. Status 02/05/2016 Page 29 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Ventilation 2.4.6 Change of term from Penetration to Opening The term penetration has been changed to Opening. Status 02/05/2016 Page 30 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software Functionalities/Bug fixing TRICAD MS TGA Modules TRICAD MS Sprinkler 2.5 TRICAD MS Sprinkler 2.5.1 K360 Sprinkler types EC-25 incorporated The selection of stationary sprinklers has been extended by adding Type E-25 from Tyko. Status 02/05/2016 Page 31 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3 Software functionalities/bug fixing TRICAD MS Factory Planning modules 3.1 TRICAD MS equipment layout 3.1.1 Thickness with system wall is now adjusted If a new system wall is created from an existing one, the thickness of the wall is now taken over. Status 02/05/2016 Page 32 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.2 Change cell colour of manipulators The button at the manipulators for changing cell colour is now stored. Status 02/05/2016 Page 33 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.3 Extension to pulldown menu to accommodate vessels and pumps The pulldown menu Electric, Media has been extended to take the items vessels and pumps. Status 02/05/2016 Page 34 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules TRICAD MS equipment layout 3.1.4 Two new robot types Two new robots to choose from: Kuka KR150 R3100 Prime and ABB IRB 5500 Status 02/05/2016 Page 35 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Trailer 3.2 Trailer 3.2.1 Show trailer seating plates Rectangular plates can be shown at the trailer corners for taking up the load. If positioning assistance is also available, the rectangular plates are aligned to this. Extension to the definition dialogue: 2. 3. 1. Extension to the data mask: Status 02/05/2016 Page 36 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Trailer 3.2.2 Place trailer storage compartment rack without vehicle With trailers that have a storage compartment rack mount, this mount can also be placed as a single object in the drawing. The storage compartment rack has its own data mask and can be adapted (parametric cell) by changing the data mask values. Status 02/05/2016 Page 37 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Trailer 3.2.3 Define name and description for storage compartment rack If storage compartment racks are placed as a separate cell without vehicle, the name and description defined here are transferred to the storage compartment rack data mask. Status 02/05/2016 Page 38 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Trailer Example: Placing of a trailer with storage compartment rack - switch ".. without placing vehicle" switched on The storage compartment rack cell receives the predefined texts as name and designation attribute. Status 02/05/2016 Page 39 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Trailer 3.2.4 Trailer entry at the rear Trailer entry from the rear has been added to the existing left and/or right entries. Status 02/05/2016 Page 40 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Conveyor systems for loading of machines 3.3 Conveyor systems for loading of machines The button of the machine design toolbox starts the conveyor system toolbox. Conveyor systems are used to transport components to and from machines. They consist of straight elements, bends, entry/exit transfer, and redirecting elements. In addition to adjustable feet, catchment trays and drive motors can be placed; direction arrows are shown on straight sections. The interference space is displayed as an option above the conveyor system. All components are created parametrically (... no cell libraries are used). Status 02/05/2016 Page 41 of 82 pages Daimler AG Status 02/05/2016 Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Conveyor systems for loading of machines Page 42 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Conveyor systems for loading of machines The toolbox makes the following functions available: Define conveyor system layout, click corner point Define conveyor system layout, click polyline Place bend Place redirection (4 construction forms available) Place exit transfer (2 construction forms available) Place adjustable feet Place drive Place or change catchment tray (place optional additional adjustable feet) Shorten or lengthen conveyor Connect conveyors across corners Reverse directional arrows Reconstruct conveyor system Change conveyor system Define conveyor system Predefined settings for all elements of the conveyor system can be selected in the toolbox: All parameters and graphics properties are defined in a conveyor system XML file. Status 02/05/2016 Page 43 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4 Platforms and maintenance platforms 3.4.1 Place stage on the clicked corner points The button of the "Create stage" toolbox opens the "Create stage, click corner points" dialogue. Status 02/05/2016 Page 44 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.2 Place stage on the clicked shape The button of the "Create stage" toolbox Status 02/05/2016 Page 45 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms Stage polygons All polygons created by MicroStation (shapes, ComplexShapes, ellipses) can be used as stage polygons. If a simple shape which contains polygon areas or circles is clicked, the program queries at each 3.4.3 Stages preview window The icon of the stages toolbox opens a preview window in which the currently set stage is shown: Status 02/05/2016 Page 46 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms The size of the window can be changed. Pressing the Status 02/05/2016 button again closes the preview window. Page 47 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.4 Place stair The button of the stage toolbox opens the stair-placing dialogue: The stair is fixed to the clicked-on endpoint. The direction is defined by clicking a second point. Place stair The program places the stair at the nearest stage edge point. Status 02/05/2016 Page 48 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms Any height can be defined. The program then searches for a suitable stair construction. A guideline is 18 steps per flight. The form of construction can be changed at any time There are 1, 2 and 3-flight stairs available Status 02/05/2016 Page 49 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms Connect storeys by stairs The stair leading to the stage (see "Set stair at stage") and beyond can also be connected to more than one storey by external stairs. Status 02/05/2016 Page 50 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.5 Place ladder The button of the stage toolbox opens the ladder-placing dialogue: Ladders can be set onto existing stages. The stage railing is automatically split when doing this. If no stage is found at the clicked-on point, the ladder can also be placed as free-standing in the model. Status 02/05/2016 Page 51 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.6 Place support The button of the stage toolbox opens the support placing dialogue: Status 02/05/2016 Page 52 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.7 Placing flaps, openings in stage railings The button of the stage toolbox opens the "Place doors, built-in elements" dialogue All buttons are described in the chapter "Set elements, doors in railings". Status 02/05/2016 Page 53 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.8 Delete 3D stage elements The button of "Display/change stage data" toolbox prompts the clicking of any 3D stage element (edge profile, floor profile, support, grid or railing). The program searches through all 3D elements of the stage cell and then deletes all 3D elements belonging to the same stage. Note: If a complete stage is copied, the link (2D stage cell to all 3D cells) is lost. See also "Stage cell" chapter. The 3D elements cannot therefore be deleted. The following message appears: A rebuilding of the copied stage must now be performed only once. The for this. Status 02/05/2016 Page 54 of 82 pages function "Rebuild stages and stairs" is available Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.9 Stages, stairs and ladders are rebuilt The button of "Display/change stage data" toolbox deletes 3D stages and 3D stair elements and then rebuilds these. For this, the 2D stage and 2D stair cells are used as building instructions. Status 02/05/2016 Page 55 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.10 Change stage and opening areas The button of "Display/change stage data" toolbox enables simple changing of stages and openings. The following dialogue mask is opened: The program automatically searches for the nearest edge or opening point. Click the corner point of a stage edge or of an opening and delete. Example: The clicked opening point has been removed, the stage rebuilt. Status 02/05/2016 Page 56 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.11 Check stage railings The button of "Display/change stage data" toolbox prompts the clicking of any 3D stage element. The program then checks whether all railing sections of the associated stage at the exits to stairs, ladders, built-in elements and possibly also through-going supports are correctly interrupted. The stage railings are automatically interrupted during the placing of stairs, ladders and built-in components. This function is only needed when stairs, ladders etc. are moved or copied using MicroStation. Example: A stair has been deleted, the gap in the stage railings must now be closed. The railings are again closed after the "Check railings" function performed. Status 02/05/2016 has been Page 57 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.12 Change stage using definition dialogue The button of "Display/change stage data" toolbox starts the function "Change stage using definition dialogue". After clicking the stage to be modified, all stage parameters are read in from the drawing and displayed in "Define stage". (Note: The stage information button function is available for quick changes to the essential stage parameters. All stage parameters can be modified using the Change Function definition dialogue). Status 02/05/2016 Page 58 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms The current settings are stored by entering a data point. The function is ended with Reset (right mouse button) and the clicked-on stage remains unchanged. Example: Change stage floor covering parameters, colours etc... and click data point (left mouse button) Status 02/05/2016 Page 59 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.13 Display stage data mask The button of "Display/change stage data" toolbox prompts the clicking of a stage element. The data mask of the steel stage is then displayed. It is also possible to set whether the stage shape element (that the TRICAD-MS data mask possesses as a linkage) is to be shown flashing. All changes to the data mask are taken over into the current stage by pressing "OK" . Status 02/05/2016 Page 60 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.14 Display stair and ladder data masks The button of "Display/change stage data" toolbox prompts the clicking of a stair or ladder element. The data mask of the stair or ladder is then displayed. It is also possible to set whether the stair element or ladder-shape element is to be shown as flashing. Changes in the data mask are accepted into the current stair by pressing "OK" . Status 02/05/2016 Page 61 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Platforms and maintenance platforms 3.4.15 Define stages The button of the stage toolbox opens the Define stage dialogue: Status 02/05/2016 Page 62 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Stage module 3.5 Stage module 3.5.1 Maintenance stages generated by new functions, analogous to Layout Functions The icon of the stages module toolbox starts the "Create steel stages, stairs, ladders" toolbox. For this, the equipment layout program triLay8i is automatically activated. As long as this steel stages toolbox is open, a second instance of the equipment layout program cannot be started. Status 02/05/2016 Page 63 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Software functionalities/bug fixing TRICAD MS Factory Planning modules Chip module 3.6 Chip module 3.6.1 Storeys / Layers Adapted for the English environment: The “lagen” or “lagen_e” file is searched for at env\db\spaene: If no "lagen" file is found at \env\db\spaene, a search is made at env\db\sani : Status 02/05/2016 Page 64 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes in DAIMLER_ENV TGA modules TRICAD MS Electrical 4 Changes in DAIMLER_ENV TGA modules 4.1 TRICAD MS Electrical 4.1.1 Cell selector without plan type differentiation In the TRICAD MS setting files 3D Electrical for Daimler, the differentiation according to plan type in the cell selector has been removed. 4.1.2 New lights 4.1.2.1 Waldmann Status 02/05/2016 Page 65 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes in DAIMLER_ENV TGA modules TRICAD MS Electrical 4.1.2.2 Regent Status 02/05/2016 Page 66 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes in DAIMLER_ENV TGA modules TRICAD MS Electrical 4.1.2.3 Tulux Status 02/05/2016 Page 67 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes in DAIMLER_ENV TGA modules TRICAD MS Electrical 4.1.2.4 ZUMTOBEL Status 02/05/2016 Page 68 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes in DAIMLER_ENV TGA modules TRICAD MS Electrical 4.1.2.5 TRILUX Status 02/05/2016 Page 69 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes in DAIMLER_ENV TGA modules TRICAD MS Electrical 4.1.2.6 CEAG Status 02/05/2016 Page 70 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes in DAIMLER_ENV TGA modules TRICAD MS Electrical 4.1.2.7 BEGA Status 02/05/2016 Page 71 of 82 pages Daimler AG Status 02/05/2016 Release Notes for TRICAD MS 2016.0 Changes in DAIMLER_ENV TGA modules TRICAD MS Electrical Page 72 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes in DAIMLER_ENV TGA modules TRICAD MS Electrical 4.1.2.8 Spectral Status 02/05/2016 Page 73 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes in DAIMLER_ENV TGA modules TRICAD MS Electrical 4.1.2.9 Ridi Status 02/05/2016 Page 74 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes in DAIMLER_ENV TGA modules TRICAD MS infrastructure module 4.2 TRICAD MS infrastructure module 4.2.1 Materials corrected The materials for the pipelines in the infrastructure module were obsolete and could, in part, no longer function. These have now been updated. Status 02/05/2016 Page 75 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes in DAIMLER_ENV TGA modules TRICAD MS Sanitary 4.3 TRICAD MS Sanitary 4.3.1 Nom. diameters in SML material supplemented The SML pipe material has been extended by the nom. diameter DN 80. Status 02/05/2016 Page 76 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes to DAIMLER_ENV factory planning modules TRICAD MS Module Layout 5 Changes to DAIMLER_ENV factory planning modules 5.1 TRICAD MS Module Layout 5.1.1 Cell selector extended The cell selector has been extended in some areas. Please set the filter “Release 05/2016" in the cell selector for further details. 5.1.2 New function for creating stages has been integrated New functions for placing simple stages have been adopted in the Daimler settings files of TRICAD MS Layout. Status 02/05/2016 Page 77 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes to DAIMLER_ENV factory planning modules TRICAD MS Module Layout 5.1.3 New function for machine loading integrated into parametric conveyor systems The new functions for placing parametric conveyor systems for machine loading have been adopted into the Daimler settings files of TRICAD MS Layout. Status 02/05/2016 Page 78 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes to DAIMLER_ENV factory planning modules TRICAD MS Module Layout 5.1.4 New settings for system walls from GEMAC Status 02/05/2016 Page 79 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes to DAIMLER_ENV factory planning modules TRICAD MS Module Layout 5.1.5 New report on area designations The lists in the settings files of TRICAD MS Layout have been extended by those from the area designation report. Status 02/05/2016 Page 80 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes to DAIMLER_ENV factory planning modules TRICAD MS Module Layout 5.1.6 Trailer parametrics adapted The parametrics of the trailers have been adapted to the current software extensions. Status 02/05/2016 Page 81 of 82 pages Daimler AG Release Notes for TRICAD MS 2016.0 Changes to DAIMLER_ENV factory planning modules Qualitool 5.2 Qualitool 5.2.1 New name assignment to file attributes Because of a changeover in file names in the FAPLIS Navigator, the automatic file-dependent rule assignment has been converted from file name assignment to file attribute assignment. The user does not see this in the program interface. To be able to use the function, work must be performed with current DGN files from the administration system, from the current TRICAD MS version and from the current Daimler ENV. Status 02/05/2016 Page 82 of 82 pages