Walers and Struts
Transcription
Walers and Struts
MGF TECHNICAL FILE TRENCH SHEETS MGF stock an extensive range of hot rolled U Piles including Arcelor Mittal and Hoesch, making us the largest independent stockist in the UK. 5.2.6 Issue 2 Tel. 01942 402 704 Simple to assemble, two sided, hydraulic bracing system designed to be used with steel trench sheets to KRUL]RQWDOO\EUDFHVPDOOWUHQFKHVIRUWKHVDIHLQVWDOODWLRQRIXWLOLWLHV7KHUDQJHFRPSULVHV¿YHW\SHVRIZDOHUUDLO DQGWZRVL]HVRIK\GUDXOLFZDOHUVWUXWWRJHWKHUZLWKPPDQGPVWUXWH[WHQVLRQEDUV7KHV\VWHPFDQ support trench widths of 0.6m to 3.8m and is normally installed using excavators. MGF also provide Vertishore, a light weight hydraulic system used to brace small trenches vertically. )DEULFDWHGIURPHLWKHUJUDGH66VWHHOSUR¿OHVRUJUDGH7DOXPLXPSUR¿OHVWKHZDOHUUDLOVDUH attached to the hydraulic struts using simple pin and retaining clip assemblies. Each strut contains a hydraulic ram with between 300mm and 670mm of stroke. Connecting the rams (via hydraulic hoses) to an MGF hand RSHUDWHGK\GUDXOLFSXPSXQLWFRQWDLQLQJK\GUDXOLFVKRULQJÀXLGDOORZVWKHWUHQFKZLGWKVWREHTXLFNO\DQG easily adjusted to suit the excavation dimensions. Once the trench frames are fully assembled and located at the correct line and level, the rams are pre-loaded against the trench sheets using a hydraulic pump. Preloading of the legs ensures the frame cannot slip and minimises the extent of potential ground movements. Self sealing quick release valves and mechanical isolation valves ensure that the hydraulic ram pressure cannot be accidently released once installed. Handling and restraining points are provided on each waler to assist assembly / removal and to allow the brace to be supported off MGF restraining chains attached to the trench sheets by hooks. WALERS AND STRUTS MGF TECHNICAL FILE Description MGF can supply the systems with a full range of suitable handling and restraining chains, Edgesafe edge protection panels, Endsafe end protection panels and struts, Laddersafe access platforms and pole ladders, 'DYLWVDIHUHWULHYDOIDOODUUHVWV\VWHPVK\GUDXOLFSXPSLQVWDOODWLRQNLWVLQFOXGLQJELRGHJUDGDEOHVKRULQJÀXLG DQGK\GUDXOLFKRVHVDQGFRQ¿QHGVSDFHVUHJLPHHTXLSPHQW Manufactured and designed in accordance with BS EN 14653:2005 PARTS 1 and 2 Manually operated Shoring Systems for Groundwork Support and BS 5975 (2008) Code of Practice for Temporary Works Procedures and the Permissible Stress Design of Falsework. Product Notes 1. Waler and trench strut systems should only be installed and removed by competent persons in accordance ZLWKDVLWHVSHFL¿FGHWDLOHGGHVLJQLQVWDOODWLRQVHTXHQFHDQG0*)LQVWDOODWLRQJXLGHOLQHV1%6WUXWV can be located at a variety of positions along the length of the waler. The exact location of the struts will determine the strength of the waler system. 2. Installation is normally carried out by lowering the assembled frame to the correct installation level and preORDGLQJHDFKVWUXWLQWXUQWRHQVXUHWKDWWKHIUDPHLVSUHVVHG¿UPO\DJDLQVWWKHWUHQFKVKHHWVDQGFDQQRW slip. Max pre-load pressure of 100Bar (1500psi) must not be exceeded. 3. Restraining chains are hung off the trench sheets and attached to the waler to assist assembly / removal of the frame and ensure vertical support is provided at all times. All the supplied restraining chains should be installed (min 2 per waler) and adjusted to ensure an even vertical load distribution. Restraining chains should never be used for lifting nor solely relied upon to suspend loads above personnel. 4. Ensure all hydraulic ram isolation valves are closed and all strut pins in place and secured using the retaining clips provided prior to commencing works. 5. Individual walers and struts should be visually inspected for damage, H[FHVVLYHGHÀHFWLRQRUORVVRIUDPSUHVVXUHSULRUWRHQWHULQJWKHH[FDYDWLRQ 6. Walers and struts should always be installed square and plumb to the excavation walls ensuring contact with all the inward facing trench sheet pans. If this is not possible any gaps must be securely packed by using KDUGZRRGZHGJHVSULRUWR¿QDOSUHORDGLQJRIWKHK\GUDXOLFUDPV 7. Safe access/egress, edge protection (for personnel) and barrier protection (for plant) should always be considered. 8. Prior to removal of systems all hydraulic rams must be released and retracted to avoid the need for excessive extraction forces and to avoid damaging the struts. 9. No matter how much care is taken during the installation and removal of waler and strut trench systems some ground movement will occur in the areas immediately surrounding the excavation. Great care must be taken when specifying these systems for use adjacent to existing structures and services. 10. Ends of trench runs should always be battered back at a safe angle or end protection panels/struts installed (see section 6). [email protected] 5.3.1 5. Issue Issu 2 MGF TECHNICAL FILE WALERS AND STRUTS MGF Edgesafe - See Section 6 MGF Pole Ladder MGF Laddersafe See Section 6 MGF Endsafe Panel See Section 6 MGF Steel Walers 5.3.2 Issue 2 MGF Trench Sheets See Section 5.2 Tel. 01942 402 704 WALERS AND STRUTS MGF TECHNICAL FILE Handling Point WLL = 2.0t Walers are lifted and handled by attaching MGF lifting chains to the handling/restraining points as shown. Waler Strut Connection Detail Waler struts are connected to the waler via a pin and retaining clip detail. [email protected] Chain to Sheet Connection Detail 7KHKRRN¿WVRYHUWKHVKHHW Restraining Chain Connection Detail There are 2 types of chains used, the top frame will use shackle to hook type, while lower frames will use shackle to shackle type. Individual chain links selected to ensure all restraining chains are evenly loaded. 5.3.3 Issue 2 MGF TECHNICAL FILE WALERS AND STRUTS 6WHHO3UR¿OHV 5.3.4 Issue 2 Type Medium Duty Steel Waler Lengths 2.0m, 2.5m & 3.0m Material Grade S275 Moment Capacity 12.7kNm Section Modulus 69cm3 Type Medium Duty Steel Waler Lengths 3.5m & 4.0m Material Grade S275 Moment Capacity 19.3kNm Section Modulus 105cm3 Type Medium Duty Steel Waler Lengths 5.0m Material Grade S275 Moment Capacity 31.4kNm Section Modulus 171cm3 Tel. 01942 402 704 Heavy Duty Steel Waler Lengths 3.0m - 5.0m Material Grade S460 Moment Capacity 40.5kNm Section Modulus 132cm3 WALERS AND STRUTS MGF TECHNICAL FILE Type $OXPLQLXP3UR¿OHV [email protected] Type Medium Duty Aluminium Waler Lengths 2.0m - 4.0m Material Grade 6082T6 Moment Capacity 18.6kNm Section Modulus 111cm3 5.3.5 Issue 2 MGF TECHNICAL FILE WALERS AND STRUTS Medium Duty Steel Waler Medium Duty Steel Walers Sheet to Sheet (mm) Desc. Waler Weight (kg) Code L (mm) W (mm) C*MAX (mm) Min Max Assembled Weight** (kg) 2000 70 1.120 2000 83 1420 565 3800 176 2500 88 1.125 2500 83 1920 565 3800 212 3000 97 1.130 3000 83 2420 565 3800 230 3500 112 1.135 3500 93 2920 565 3800 260 4000 129 1.240 4000 93 3420 565 3800 294 5000 180 1.250 5000 116 4370 565 3800 396 * ** Depends of strut locations Assembled weight includes 2 No. type 800 struts Heavy Duty Steel Waler Heavy Duty Steel Walers Desc. Waler Weight (kg) Code L (mm) W (mm) C*MAX (mm) Min Max Assembled Weight** (kg) 3000 100 1.330 3000 108 2420 565 3800 236 4000 133 1.340 4000 108 3420 565 3800 302 5000 166 1.350 5000 108 4420 565 3800 368 * ** 5.3.6 Issue 2 Sheet to Sheet (mm) Depends of strut locations Assembled weight includes 2 No. type 800 struts Tel. 01942 402 704 WALERS AND STRUTS MGF TECHNICAL FILE Medium Duty Aluminium Waler Medium Duty Aluminium Walers Sheet to Sheet (mm) Desc. Waler Weight (kg) Code L (mm) W (mm) C*MAX (mm) Min Max Assembled Weight** (kg) 1500 18 1.015 1500 100 1010 565 3800 78 2000 24 1.020 2000 100 1510 565 3800 84 2500 30 1.025 2500 100 1910 565 3800 96 3000 36 1.030 3000 100 2410 565 3800 108 4000 47 1.040 4000 100 3310 565 3800 130 * ** [email protected] Depends of strut locations Assembled weight includes 2 No. type 800 struts 5.3.7 Issue 2 MGF TECHNICAL FILE WALERS AND STRUTS 80kN Single Acting Hydraulic Ram Assembly Hydraulic Cylinder Single Acting Material Aluminium Bore 50.8mm Max .Working Pressure 400 Bar (6000 psi) Test Pressure 400 Bar (6000 psi) Approx. Working Stroke 800mm Axial SWL 80kN Min. FOS (by test) 2 Working Temp Range -20ºC* to +50ºC Approx. Pre-Load 20kN Locating Pins ĭ18 and ĭ20mm :LQWHUPL[UHTXLUHGIRUVKRULQJÀXLGDWORZWHPSV 6KRULQJ ÀXLG LV SXPSHG LQWR the full bore side of the piston through the male QRV. Single acting cylinders cannot be retracted using a pump unit and have to be physically closed whilst releasing the male QRV. Ensure isolation valve is closed to maintain pre-load pressure and before release/ connection of QRV’s. Pump Units The pump is used to extend and retract the waler strut single acting hydraulic rams. The pumps contain bio-degradable Houghto Safe SF25 VKRULQJÀXLG'XULQJWKH6XPPHUPRQWKVWKHVKRULQJÀXLGLV diluted with water at a ratio of 3 parts water to 1 part Houghto Safe SF25. In the Winter the mix ratio is 1:1. Maximum recommended installation pressure 1500 psi (100 Bar). 5.3.8 Issue 2 Product ID 1.602 (SA) Capacity 20 litres Shoring Fluid Houghto Safe SF25 Installation Pressure 0-1500 psi Tel. 01942 402 704 WALERS AND STRUTS MGF TECHNICAL FILE The waler hydraulic strut is connected to the waler using a pin and retaining clip detail. Waler Struts - Hydraulic Single acting (SWL=80kN) Ext. Dims. Type Code Min Max Weight (kg) 600 (A) 1.455 550 900 13 800 (C) 1.480 800 1400 18 Min Max Weight (kg) Ext. 1 1.525 250 N/A 5 2 1.550 500 N/A 10 3 1.510 1000 N/A 20 The waler strut extension is bolted to the hydraulic strut using 4 No. M10 grade 8.8 bolts c/w nuts and washers. The strut extension is connected to the waler using a pin and retaining clip detail. Extension bar 88.9 x 5.0 CHS Grade S275 [email protected] 5.3.9 Issue 2 MGF TECHNICAL FILE WALERS AND STRUTS 5.3.10 Issue 2 SWL for Medium Duty Steel Walers at Various Strut Positions Tel. 01942 402 704 WALERS AND STRUTS MGF TECHNICAL FILE SWL for Heavy Duty Steel Walers at Various Strut Positions SWL for Aluminium Walers at Various Strut Positions [email protected] 5.3.11 Issue 2 MGF TECHNICAL FILE WALERS AND STRUTS Aluminium Vertishore SWL = 20kN/m (on Vertishore) * 5.3.12 Issue 2 Desc. Product ID Weight* (kg) 1500 1.014 28 2000 1.013 35 Assembled weight (excluding boards) with type A struts Pre-assembled, light weight, two sided hydraulic waler strut system designed to be installed from ground level directly against a soil face in the vertical plane. Suitable for trenches up to 2.0m deep and 1.4m wide. The System can be installed E\RQHSHUVRQDQGLVXVXDOO\VSHFL¿HGIRUVKRUW term utilities type trench work where the ground is considered self supporting and capable of arching a min. 1.5m between preloaded hydraulic vertical supports for the duration of the works. Backing boards are available to prevent localised pockets of loose material entering the excavation. Personnel should only enter and work in the space between two vertishores. A competent person should always inspect the excavation before allowing access to ensure that all the struts are pre-loaded and bearing directly onto the soil, the exposed soil faces are self supporting with no evidence of water ingress or very loose material. Vertical support must be provided at a max. 1.5m KRUL]RQWDOO\ Always install and remove the system from ground level and away from any potentially unstable edges. Vertishores are supplied with an installation kit, including a pump unit, lowering hook and valve release tool. Available hydraulic struts Type A : 550-900mm Type B: 700-1200mm Type C: 800-1400mm Tel. 01942 402 704 WALERS AND STRUTS MGF TECHNICAL FILE Waler End Protection Strut MGF Endsafe Struts are suitable for use in smaller excavations when it is not possible to safely batter the ends of the trench back to ground level. The simple telescopic strut system can be easily installed and removed by one person at the end of a waler run to support trench sheets. The pin connecting the inner and outer sections should always be used for safe handling purposes and can be removed once installed. The minimum overlap between the strut inner and outer is Inner Material 90x90x4 SHS (S355) Inner Unit Mass 10.5kg/m Outer Material 100x100x4 SHS (S355) Outer Unit Mass 11.9kg/m Waler Hydraulic Strut and EndSafe Strut Connection Pin [email protected] Pin ĭPPEDUPP long Material Grade 080M40 (EN8) Shear SWL 80kN 5.3.13 Issue 2 Safe Working Load for MGF End Protection Struts ϭϬϬ͘Ϭ ϵϬ͘Ϭ ϴϬ͘Ϭ ^ĂĨĞtŽƌŬŝŶŐ>ŽĂĚ;ŬEͬŵͿ MGF TECHNICAL FILE WALERS AND STRUTS Safe Working Load for Waler End Protection Struts ϳϬ͘Ϭ ϲϬ͘Ϭ ϱϬ͘Ϭ ϰϬ͘Ϭ ϯϬ͘Ϭ ϲϯϰ /ŶŶĞƌ ϮϬ͘Ϭ ϭϭϯϰ /ŶŶĞƌ ϭϯϴϰ /ŶŶĞƌ ϴϯϰ /ŶŶĞƌ ϭϬ͘Ϭ Ϭ͘Ϭ Ϭ͘ϲϱ Ϭ͘ϳϱ Ϭ͘ϴϱ Ϭ͘ϵϱ ϭ͘Ϭϱ ϭ͘ϭϱ ϭ͘Ϯϱ ϭ͘ϯϱ ϭ͘ϰϱ ϭ͘ϱϱ ϭ͘ϲϱ ϭ͘ϳϱ ^ŚĞĞƚƚŽ^ŚĞĞƚŝŵĞŶƐŝŽŶ;ŵͿ Recommended SWL Arrows indicate recommended inner section lengths to achieve desired range. 5.3.14 Issue 2 Tel. 01942 402 704