QM3A - Multi-Dec k
Transcription
QM3A - Multi-Dec k
8’ 12’ STD Fan 0.35/1 0.70/2 0.70/2 1.05/3 PSC Fan 0.22/1 0.44/2 0.44/2 0.66/3 ECM Fan 0.20/1 0.40/2 0.40/2 0.60/3 0.50 0.80 1.00 1.50 Light 8 337 0.50 15° D N SL OPE 0.75 1 54 8 Defrost Heater 3.30 (Electric - 230V) 5.61 7.93 E (Per row) 0.40 N LI 0.25 8 IT M 14 8 Lighted Shelves 313 LI (Double canopy, unlighted shelves) 215 22 11.54 32 61 8 All electrical data based on 115V and unlighted shelves. For lighted shelves, please add 0.25 amps per shelf. 233 4 155 8 DEFROST CONTROLS 51 2 4 Defrost Per Day Fail Safe Termination Off Cycle 4 35min 48°F Hot gas 4 20 min 48°F Electric 4 35 min 48°F 61 221 8 4 7 8 20 8 85 8 437 8 Add 3” thickness for a pair of ends. Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75°F and 55% relative humidity. Kysor//Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost® are registered trademarks of Kysor//Warren®. CAPACITIES BTUH per FT STD Fan PSC Fan 928 ECM Fan 918 NOTE: For sizing conventional/individual condensing units, add 8% to BTUH load. For lighted shelves, please add 19 BTUH. 6’ 4’ 938 2 Facing Area 11.9 ft 17.8 ft Cubic Capacity 20.2 ft3 30.2 ft3 800-866-5596 phone 706-568-8990 fax 12’ 2 35.6 ft2 40.3 ft3 60.5 ft3 23.8 ft Evap Temp Discharge Air Velocity (1 hr after discharge) Discharge Air Temp +24°F 250 FPM 29°F The above case model, has case lengths that are UL and NSF approved. Kysor//Warren 5201 Transport Blvd Columbus, GA 31907 8’ 2 www.kysorwarren.com Issue: 10.13.2009 QM3A - Multi-Deck 6’ AD LO 4’ Applications: CASE DATA AMPS 12’ Secondary Coolant: Glycol (Propylene) 35% 35% BTUH Heat Load 7504 11256 Glycol Temp Rise +6°F +6°F Glycol Flow Rate (GPM) 2.70 4.10 Pressure Drop (PSI) 3.70 8.50 STD Fan / # of Fans 0.70/2 1.05/3 PSC Fan / # of Fans 0.44/2 0.66/3 8 313 LO 8 AD 1.00 1.50 0.50 0.75 8 E N LI 0.60/3 14 IT M 0.40/2 337 LI ECM Fan / # of Fans 215 15° D N SL 541 22 8 OPE 32 Light (Double canopy, unlighted shelves) Lighted Shelves (Per row) Defrost Heater (Electric - 230V) 7.93 61 8 233 4 155 11.54 8 All electrical data based on 115V and unlighted shelves. For lighted shelves, please add 0.25 amps per shelf. 61 Defrost Per Day Fail Safe Termination 4 35min 48°F Hot gas 4 20 min 48°F Electric 4 35 min 48°F 4 207 2 85 8 8 DEFROST CONTROLS Off Cycle 51 4 221 8 8 437 8 Add 3” thickness for a pair of ends. Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75°F and 55% relative humidity. Kysor//Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost® are registered trademarks of Kysor//Warren®. BTUH per FT STD Fan CAPACITIES 4’ 938 6’ 2 PSC Fan 928 Facing Area 11.9 ft ECM Fan 918 Cubic Capacity 20.2 ft3 NOTE: For sizing conventional/individual condensing units, add 8% to BTUH load. For lighted shelves, please add 19 BTUH. 800-866-5596 phone 706-568-8990 fax 35.6 ft2 40.3 ft3 60.5 ft3 23.8 ft 30.2 ft3 12’ 2 Supply Temp Discharge Air Velocity (1 hr after discharge) Discharge Air Temp +20°F 250 FPM 29°F The above case model, has case lengths that are UL and NSF approved. Kysor//Warren 5201 Transport Blvd Columbus, GA 31907 17.8 ft 8’ 2 www.kysorwarren.com Issue: 3.22.2010 QM3A - Glycol - Multi-Deck 8’ Applications: CASE DATA AMPS 6’ 8’ 12’ STD Fan / # of Motors 0.35/1 0.70/2 0.70/2 1.05/3 PSC Fan / # of Motors 0.22/1 0.44/2 0.44/2 0.66/3 ECM Fan / # of Motors 0.20/1 0.40/2 0.40/2 0.60/3 0.50 0.80 1.00 1.50 0.25 0.40 0.50 0.75 3.30 5.61 7.93 11.54 Light (Double canopy, unlighted shelves) Lighted Shelves (Per row) Defrost Heater (Electric - 230V) All electrical data based on 115V and unlighted shelves. For lighted shelves, please add 0.25 amps per shelf. DEFROST CONTROLS Defrost Per Day Fail Safe Termination Off Cycle 4 35min 48°F Hot gas 4 20 min 48°F Electric 4 35 min 48°F Add 3” thickness for a pair of ends. Note: Installation & Operation Manual for this model contains detailed information regarding this case. CAPACITIES BTUH per FT STD Fan The above case model, has case lengths that are UL and NSF approved. PSC Fan 928 ECM Fan 918 6’ 4’ 938 NOTE: For sizing conventional/ individual condensing units, add 8% to BTUH load. For lighted shelves, please add 19 BTUH. 2 Facing Area 11.9 ft Cubic Capacity 20.2 ft3 17.8 ft 8’ 2 30.2 ft3 12’ 2 23.8 ft 35.6 ft2 40.3 ft3 60.5 ft3 Evap Temp Discharge Air Velocity (1 hr after discharge) Discharge Air Temp +24°F 250 FPM 29°F Issue: 7.10.2008 Kysor//Warren 5201 Transport Blvd Columbus, GA 31907 800-866-5596 phone 706-568-8990 fax www.kysorwarren.com Specification Sheet Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75°F and 55% relative humidity. Kysor//Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost® are registered trademarks of Kysor//Warren®. QM3AG - Multi-Deck 4’ Applications: CASE DATA AMPS 6’ 8’ 12’ % PG 35% 35% 35% 35% BTUH Heat Load 3752 5628 7504 11256 Glycol Temp Rise +6°F +6°F +6°F +6°F Glycol Flow Rate (GPM) 1.40 2.10 2.70 4.10 Glycol Pressure Drop (PSI) 0.80 2.10 3.70 8.50 STD Fan / # Fans 0.35/1 0.70/2 0.70/2 1.05/3 PSC Fan / # Fans 0.22/1 0.44/2 0.44/2 0.66/3 ECM Fan / # Fans 0.20/1 0.40/2 0.40/2 0.60/3 0.50 0.80 1.00 1.50 0.25 0.40 0.50 0.75 Light (Double canopy, unlighted shelves) Lighted Shelves (Per row) Defrost Heater (Electric - 230V) 3.30 5.61 7.93 Add 3” thickness for a pair of ends. DEFROST CONTROLS Defrost Per Day Off Cycle 4 35 min 48°F Warm Fluid 4 20 min 48°F Electric 4 35 min 48°F 11.54 All electrical data based on 115V and unlighted shelves. For lighted shelves, add 0.25 amps per shelf. Fail Safe Termination Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75°F and 55% relative humidity. Kysor//Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost® are registered trademarks of Kysor//Warren®. CAPACITIES BTUH per FT STD Fan 2 Facing Area (ft ) 938 3 Cubic Capacity (ft ) PSC Fan ECM Fan Kysor//Warren 5201 Transport Blvd Columbus, GA 31907 928 4’ 6’ 8’ 12’ 11.9 17.8 23.8 35.6 20.2 30.2 40.3 60.5 Supply Temp Discharge Air Velocity (1 hr after discharge) Discharge Air Temp +24°F 250 FPM 29°F 918 Issue: 3.23.2010 800-866-5596 phone 706-568-8990 fax www.kysorwarren.com QM3AG - G - Multi-Deck - Glycol 4’ Applications: CASE DATA AMPS 6’ 8’ 12’ STD Fan / # of Motors 0.35/1 0.70/2 0.70/2 1.05/3 PSC Fan / # of Motors 0.22/1 0.44/2 0.44/2 0.66/3 ECM Fan / # of Motors 0.20/1 0.40/2 0.40/2 0.60/3 0.47 0.68 0.94 1.41 3.30 5.61 7.93 11.54 Light (One Row of T5) Defrost Heater (Electric - 230V) All electrical data based on 115V and unlighted shelves. For lighted shelves, please add 0.25 amps per shelf. DEFROST CONTROLS Defrost Per Day Fail Safe Termination Off Cycle 4 35min 48°F Hot gas 4 20 min 48°F Electric 4 35 min 48°F Note: Installation & Operation Manual for this model contains detailed information regarding this case. Add 3” thickness for a pair of ends. Specification Sheet Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75°F and 55% relative humidity. Kysor//Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost® are registered trademarks of Kysor//Warren®. BTUH per FT The above case model, has case lengths that are UL and NSF approved. STD Fan 983.5 PSC Fan 975.5 ECM Fan 965.5 CAPACITIES NOTE: For sizing conventional/ individual condensing units, add 8% to BTUH load. For lighted shelves, please add 19 BTUH. 4’ 6’ 8’ 12’ Facing Area 11.1 16.7 22.2 33.3 Cubic Capacity 19.3 28.9 38.5 57.7 Evap Temp Discharge Air Velocity (1 hr after discharge) Discharge Air Temp +24°F 250 FPM 29°F Issue: 7.11.2008 Kysor//Warren 5201 Transport Blvd Columbus, GA 31907 800-866-5596 phone 706-568-8990 fax www.kysorwarren.com QM3GD- Multi-Deck 4’ Applications: CASE DATA AMPS 12’ 35% Propylene 35% Propylene BTUH Heat Load 7804 11706 Glycol Supply Temp +20°F +20°F Glycol Temp Rise +6°F +6°F Glycol Flow Rate 2.90 GPM 4.30 GPM 4.0 9.2 STD Fan Amps 0.70/2 1.05/3 PSC Fan Amps 0.44/2 0.66/3 ECM Fan Amps 0.40/2 0.60/3 0.94 1.41 Secondary Coolant: Glycol Pressure Drop (PSI) T5 HO Lights Amps (one row) All electrical data based on 115V and unlighted shelves. For lighted shelves, please add 0.25 amps per shelf. DEFROST CONTROLS Defrost Per Day Fail Safe Termination Off Cycle 4 35min +48°F Add 3” thickness for a pair of ends. Specification Sheet Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75°F and 55% relative humidity. Kysor//Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost® are registered trademarks of Kysor//Warren®. BTUH per FT STD Fan 984 PSC Fan 976 ECM Fan 966 Supply Temp Discharge Air Velocity (1 hr after defrost) Discharge Air Temp +20°F 250 FPM 29°F CAPACITIES Length Facing Area Cubic Capacity 8’ 22.2 ft² 38.5 ft³ 12’ 33.3 ft² 57.7 ft³ The above case model, has case lengths that are UL and NSF approved. Kysor//Warren 5201 Transport Blvd Columbus, GA 31907 800-866-5596 phone 706-568-8990 fax www.kysorwarren.com Issue: 3.23.2010 QM3GD - Glycol - Multi-Deck 8’ Applications: CASE DATA 8’ 12’ STD Fan / # of Motors 0.70/2 0.70/2 1.05/3 PSC Fan / # of Motors 0.44/2 0.44/2 0.66/3 ECM Fan / # of Motors 0.60/2 0.60/2 0.90/3 Lighted Shelves (Per row) Electric Defrost Heater (Optional 230 V) 0.40 0.50 0.75 5.61 7.93 11.54 All electrical data based on 115V and unlighted shelves. For lighted shelves, please add 0.25 amps per shelf. DEFROST CONTROLS Defrost Per Day Fail Safe Termination Electric 4 35 min 48°F Hot gas 4 20 min 48°F Off Cycle 4 40 min 48°F Assorted Shelving Options Available. Add 3” thickness for a pair of ends. 3 - 12' CASE 1448 963 - 8' CASE 8 1 - 6' CASE 724 213 4 5 STUB UP 58 AREA 101 8 10 22 41 8 587 8 35 1 48 STUB UP AREA 22 10 71 8 KICKPLATE LOCATION DRAIN CONNECTION (W/TRAP RIGHT OR LEFT) ELECTRICAL PENETRATION (TYP) REFRIGERATION PENETRATION (TYP) Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75°F and 55% relative humidity. Kysor/Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost® are registered trademarks of Kysor/Warren®. CAPACITIES BTUH per Side (unlighted shelves) 6’ 8’ 6’ 12’ 8’ 2 STD Fan 5628 7504 11256 Facing Area (per side) 17.8 ft PSC Fan 5568 7424 11136 Cubic Capacity (per side) 30.2 ft3 ECM Fan 5508 7344 11016 NOTE: For sizing conventional or individual condensing units, add 8% to BTUH load. For lighted shelves, add 19 BTUH per FT per row of lighted shelves. 12’ 2 23.8 ft 35.6 ft2 40.3 ft3 60.5 ft3 Evap Temp Discharge Air Velocity (1 hr. after defrost) Discharge Air Temp +24°F 250 FPM +29°F Issue: 8.24.2011 Kysor/Warren 5201 Transport Blvd Columbus, GA 31907 800-866-5596 phone 706-568-8990 fax www.kysorwarren.com Specification Sheet 503 4 STUB UP AREA 55 8 213 4 1 78 QM3T - 6’ 8’ 12’ Twin Island 6’ Applications: Case Data Amps per Side STD Fan / No. of Motors 0.70/2 PSC Fan / No. of Motors 0.44/2 ECM Fan / No. of Motors 0.60/2 Lighted Shelves (Per row) 0.40 Electric Defrost Heater 5.61 (Optional 230 V) All electrical data based on 115V and unlighted shelves. For lighted shelves, please add 0.25 amps per shelf. DEFROST CONTROLS Defrost Per Day Fail Safe Termination Electric 4 35 min 48°F Hot gas 4 20 min 48°F Off Cycle 4 40 min 48°F Assorted Shelving Options Available. 40 20 Add 3” thickness for a pair of ends. 71 8 STUB UP 55 8 AREA 503 4 STUB UP AREA 35 STUB UP 55 8 AREA 22 1 78 3 ELECTRICAL PENETRATION (TYP) Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75°F and 55% relative humidity. Kysor/Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost® are registered trademarks of Kysor/Warren®. BTUH - 4’ End (unlighted shelves) STD Fan 5628 PSC Fan 5568 ECM Fan 5508 NOTE: For sizing conventional or individual condensing units, add 8% to BTUH load. For lighted shelves, add 19 BTUH per FT per row of lighted shelves. CAPACITIES — 4’ End Facing Area 17.8 ft2 Cubic Capacity 30.2 ft3 Evap Temp Discharge Air Velocity (1 hr. after defrost) Discharge Air Temp +24°F 250 FPM +29°F Issue: 8.24.2011 Kysor/Warren 5201 Transport Blvd Columbus, GA 31907 800-866-5596 phone 706-568-8990 fax www.kysorwarren.com Specification Sheet 79 22 QM3TE - 4’ Island End Case 4 ‘ End Applications: CASE DATA AMPS 8’ Side STD Fan / No. of Motors 0.70/2 0.70/2 PSC Fan / No. of Motors 0.44/2 0.44/2 ECM Fan / No. of Motors 0.60/2 0.60/2 0.40 0.50 5.61 7.93 Lighted Shelves (Per row) Electric Defrost Heater (Optional 230 V) All electrical data based on 115V and unlighted shelves. For lighted shelves, please add 0.25 amps per shelf. DEFROST CONTROLS Defrost Per Day Fail Safe Termination Electric 4 35 min 48°F Hot gas 4 20 min 48°F Off Cycle 4 40 min 48°F 8’ Cross-Section See End Case Spec Sheet for End Case Cross-Section. Assorted Shelving Options Available. Add 3” thickness for a pair of ends. Specification Sheet Plan View See End Case Spec Sheet for End Case Plan View. Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75°F and 55% relative humidity. Kysor/Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost® are registered trademarks of Kysor/Warren®. BTUH per Side (unlighted shelves) CAPACITIES 4’ End 4’ End 8’ Side 2 23.8 ft2 40.3 ft3 8’ Side STD Fan 5628 7504 Facing Area 17.8 ft PSC Fan 5568 7424 Cubic Capacity 30.2 ft3 ECM Fan 5508 7344 NOTE: For sizing conventional or individual condensing units, add 8% to BTUH load. For lighted shelves, add 19 BTUH per FT per row of lighted shelves. Evap Temp Discharge Air Velocity (1 hr. after defrost) Discharge Air Temp +24°F 250 FPM +29°F Issue: 8.24.2011 Kysor/Warren 5201 Transport Blvd Columbus, GA 31907 800-866-5596 phone 706-568-8990 fax www.kysorwarren.com QM3TE - 12’ Twin Island with Unitized End Case 4’ End Applications: Case Data Amps per side End Case Cross-Section Assorted Shelving Options Available. 8’ Cross-Section Add 3” thickness for a pair of ends Kysor/Warren 5201 Transport Blvd Columbus, GA 31907 800-866-5596 phone 706-568-8990 fax www.kysorwarren.com QM3TE 12’ Unitized Island Cross-Section Drawings 12’ Unitized Island Cross-Section Drawings QM3TE
Similar documents
Q FG T -A - R eac h In - S ta ndard D oor (Anthony ) A
FLOOR PENETRATION AREA. PLUMBING, ELECTRICAL, & REFRIGERATION LINES.
More informationWe Listen, Respond... and Deliver!
All electrical data are based on 115V and unlighted shelves.
More information