QM3A - Multi-Dec k

Transcription

QM3A - Multi-Dec k
8’
12’
STD Fan
0.35/1
0.70/2
0.70/2
1.05/3
PSC Fan
0.22/1
0.44/2
0.44/2
0.66/3
ECM Fan
0.20/1
0.40/2
0.40/2
0.60/3
0.50
0.80
1.00
1.50
Light
8
337
0.50
15° D
N SL
OPE
0.75
1
54
8
Defrost Heater
3.30
(Electric - 230V)
5.61
7.93
E
(Per row)
0.40
N
LI
0.25
8
IT
M
14
8
Lighted Shelves
313
LI
(Double canopy, unlighted
shelves)
215
22
11.54
32
61
8
All electrical data based on 115V and unlighted shelves. For
lighted shelves, please add 0.25 amps per shelf.
233
4
155
8
DEFROST CONTROLS
51
2
4
Defrost
Per Day
Fail Safe
Termination
Off Cycle
4
35min
48°F
Hot gas
4
20 min
48°F
Electric
4
35 min
48°F
61
221
8
4
7
8
20
8
85
8
437
8
Add 3” thickness for a pair of ends.
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such
that conditions do not exceed 75°F and 55% relative humidity. Kysor//Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet®
and Air Defrost® are registered trademarks of Kysor//Warren®.
CAPACITIES
BTUH per FT
STD Fan
PSC Fan
928
ECM Fan
918
NOTE: For sizing conventional/individual
condensing units, add 8% to BTUH load.
For lighted shelves, please add 19 BTUH.
6’
4’
938
2
Facing Area
11.9 ft
17.8 ft
Cubic Capacity
20.2 ft3
30.2 ft3
800-866-5596 phone
706-568-8990 fax
12’
2
35.6 ft2
40.3 ft3
60.5 ft3
23.8 ft
Evap Temp
Discharge Air Velocity
(1 hr after discharge)
Discharge Air
Temp
+24°F
250 FPM
29°F
The above case model, has case lengths
that are UL and NSF approved.
Kysor//Warren
5201 Transport Blvd
Columbus, GA 31907
8’
2
www.kysorwarren.com
Issue: 10.13.2009
QM3A - Multi-Deck
6’
AD
LO
4’
Applications:
CASE DATA AMPS
12’
Secondary Coolant: Glycol
(Propylene)
35%
35%
BTUH Heat Load
7504
11256
Glycol Temp Rise
+6°F
+6°F
Glycol Flow Rate (GPM)
2.70
4.10
Pressure Drop (PSI)
3.70
8.50
STD Fan / # of Fans
0.70/2
1.05/3
PSC Fan / # of Fans
0.44/2
0.66/3
8
313
LO
8
AD
1.00
1.50
0.50
0.75
8
E
N
LI
0.60/3
14
IT
M
0.40/2
337
LI
ECM Fan / # of Fans
215
15° D
N SL
541
22
8
OPE
32
Light
(Double canopy, unlighted shelves)
Lighted Shelves (Per row)
Defrost Heater (Electric - 230V)
7.93
61
8
233
4
155
11.54
8
All electrical data based on 115V and unlighted shelves. For
lighted shelves, please add 0.25 amps per shelf.
61
Defrost
Per Day
Fail Safe
Termination
4
35min
48°F
Hot gas
4
20 min
48°F
Electric
4
35 min
48°F
4
207
2
85
8
8
DEFROST CONTROLS
Off Cycle
51
4
221
8
8
437
8
Add 3” thickness for a pair of ends.
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such
that conditions do not exceed 75°F and 55% relative humidity. Kysor//Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet®
and Air Defrost® are registered trademarks of Kysor//Warren®.
BTUH per FT
STD Fan
CAPACITIES
4’
938
6’
2
PSC Fan
928
Facing Area
11.9 ft
ECM Fan
918
Cubic Capacity
20.2 ft3
NOTE: For sizing conventional/individual
condensing units, add 8% to BTUH load.
For lighted shelves, please add 19 BTUH.
800-866-5596 phone
706-568-8990 fax
35.6 ft2
40.3 ft3
60.5 ft3
23.8 ft
30.2 ft3
12’
2
Supply Temp
Discharge Air Velocity
(1 hr after discharge)
Discharge Air
Temp
+20°F
250 FPM
29°F
The above case model, has case lengths
that are UL and NSF approved.
Kysor//Warren
5201 Transport Blvd
Columbus, GA 31907
17.8 ft
8’
2
www.kysorwarren.com
Issue: 3.22.2010
QM3A - Glycol - Multi-Deck
8’
Applications:
CASE DATA AMPS
6’
8’
12’
STD Fan / # of Motors
0.35/1
0.70/2
0.70/2
1.05/3
PSC Fan / # of Motors
0.22/1
0.44/2
0.44/2
0.66/3
ECM Fan / # of Motors
0.20/1
0.40/2
0.40/2
0.60/3
0.50
0.80
1.00
1.50
0.25
0.40
0.50
0.75
3.30
5.61
7.93
11.54
Light
(Double canopy, unlighted shelves)
Lighted Shelves
(Per row)
Defrost Heater
(Electric - 230V)
All electrical data based on 115V and unlighted shelves. For lighted
shelves, please add 0.25 amps per shelf.
DEFROST CONTROLS
Defrost
Per Day
Fail Safe
Termination
Off Cycle
4
35min
48°F
Hot gas
4
20 min
48°F
Electric
4
35 min
48°F
Add 3” thickness for a pair of ends.
Note: Installation & Operation Manual for this model contains detailed
information regarding this case.
CAPACITIES
BTUH per FT
STD Fan
The above case model,
has case lengths that are
UL and NSF approved.
PSC Fan
928
ECM Fan
918
6’
4’
938
NOTE: For sizing conventional/
individual condensing units, add 8%
to BTUH load. For lighted shelves,
please add 19 BTUH.
2
Facing Area
11.9 ft
Cubic Capacity
20.2 ft3
17.8 ft
8’
2
30.2 ft3
12’
2
23.8 ft
35.6 ft2
40.3 ft3
60.5 ft3
Evap
Temp
Discharge Air Velocity
(1 hr after discharge)
Discharge Air
Temp
+24°F
250 FPM
29°F
Issue: 7.10.2008
Kysor//Warren
5201 Transport Blvd
Columbus, GA 31907
800-866-5596 phone
706-568-8990 fax
www.kysorwarren.com
Specification Sheet
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that
conditions do not exceed 75°F and 55% relative humidity. Kysor//Warren®, whose policy is one of continuous improvement,
reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost®
are registered trademarks of Kysor//Warren®.
QM3AG - Multi-Deck
4’
Applications:
CASE DATA AMPS
6’
8’
12’
% PG
35%
35%
35%
35%
BTUH Heat Load
3752
5628
7504
11256
Glycol Temp Rise
+6°F
+6°F
+6°F
+6°F
Glycol Flow Rate
(GPM)
1.40
2.10
2.70
4.10
Glycol Pressure Drop
(PSI)
0.80
2.10
3.70
8.50
STD Fan / # Fans
0.35/1
0.70/2
0.70/2
1.05/3
PSC Fan / # Fans
0.22/1
0.44/2
0.44/2
0.66/3
ECM Fan / # Fans
0.20/1
0.40/2
0.40/2
0.60/3
0.50
0.80
1.00
1.50
0.25
0.40
0.50
0.75
Light
(Double canopy,
unlighted shelves)
Lighted Shelves
(Per row)
Defrost Heater
(Electric - 230V)
3.30
5.61
7.93
Add 3” thickness for a pair of ends.
DEFROST CONTROLS
Defrost
Per Day
Off Cycle
4
35 min
48°F
Warm Fluid
4
20 min
48°F
Electric
4
35 min
48°F
11.54
All electrical data based on 115V and unlighted shelves. For
lighted shelves, add 0.25 amps per shelf.
Fail Safe Termination
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that
conditions do not exceed 75°F and 55% relative humidity. Kysor//Warren®, whose policy is one of continuous improvement,
reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost® are registered trademarks of Kysor//Warren®.
CAPACITIES
BTUH per FT
STD Fan
2
Facing Area (ft )
938
3
Cubic Capacity (ft )
PSC Fan
ECM Fan
Kysor//Warren
5201 Transport Blvd
Columbus, GA 31907
928
4’
6’
8’
12’
11.9
17.8
23.8
35.6
20.2
30.2
40.3
60.5
Supply Temp
Discharge Air Velocity
(1 hr after discharge)
Discharge Air
Temp
+24°F
250 FPM
29°F
918
Issue: 3.23.2010
800-866-5596 phone
706-568-8990 fax
www.kysorwarren.com
QM3AG - G - Multi-Deck - Glycol
4’
Applications:
CASE DATA AMPS
6’
8’
12’
STD Fan / # of Motors
0.35/1
0.70/2
0.70/2
1.05/3
PSC Fan / # of Motors
0.22/1
0.44/2
0.44/2
0.66/3
ECM Fan / # of Motors
0.20/1
0.40/2
0.40/2
0.60/3
0.47
0.68
0.94
1.41
3.30
5.61
7.93
11.54
Light (One Row of T5)
Defrost Heater
(Electric - 230V)
All electrical data based on 115V and unlighted shelves.
For lighted shelves, please add 0.25 amps per shelf.
DEFROST CONTROLS
Defrost
Per Day
Fail Safe
Termination
Off Cycle
4
35min
48°F
Hot gas
4
20 min
48°F
Electric
4
35 min
48°F
Note: Installation & Operation Manual for this model contains detailed information regarding this case.
Add 3” thickness for a pair of ends.
Specification Sheet
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that
conditions do not exceed 75°F and 55% relative humidity. Kysor//Warren®, whose policy is one of continuous improvement,
reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost® are registered trademarks of Kysor//Warren®.
BTUH per FT
The above case model,
has case lengths that are
UL and NSF approved.
STD Fan
983.5
PSC Fan
975.5
ECM Fan
965.5
CAPACITIES
NOTE: For sizing conventional/
individual condensing units, add 8%
to BTUH load. For lighted shelves,
please add 19 BTUH.
4’
6’
8’
12’
Facing Area
11.1
16.7
22.2
33.3
Cubic Capacity
19.3
28.9
38.5
57.7
Evap
Temp
Discharge Air Velocity
(1 hr after discharge)
Discharge
Air Temp
+24°F
250 FPM
29°F
Issue: 7.11.2008
Kysor//Warren
5201 Transport Blvd
Columbus, GA 31907
800-866-5596 phone
706-568-8990 fax
www.kysorwarren.com
QM3GD- Multi-Deck
4’
Applications:
CASE DATA AMPS
12’
35%
Propylene
35%
Propylene
BTUH Heat Load
7804
11706
Glycol Supply Temp
+20°F
+20°F
Glycol Temp Rise
+6°F
+6°F
Glycol Flow Rate
2.90 GPM
4.30 GPM
4.0
9.2
STD Fan Amps
0.70/2
1.05/3
PSC Fan Amps
0.44/2
0.66/3
ECM Fan Amps
0.40/2
0.60/3
0.94
1.41
Secondary Coolant:
Glycol
Pressure Drop (PSI)
T5 HO Lights Amps
(one row)
All electrical data based on 115V and unlighted shelves.
For lighted shelves, please add 0.25 amps per shelf.
DEFROST CONTROLS
Defrost
Per Day
Fail Safe
Termination
Off Cycle
4
35min
+48°F
Add 3” thickness for a pair of ends.
Specification Sheet
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such
that conditions do not exceed 75°F and 55% relative humidity. Kysor//Warren®, whose policy is one of continuous
improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation.
Dual-Jet® and Air Defrost® are registered trademarks of Kysor//Warren®.
BTUH per FT
STD Fan
984
PSC Fan
976
ECM Fan
966
Supply
Temp
Discharge Air
Velocity
(1 hr after defrost)
Discharge
Air Temp
+20°F
250 FPM
29°F
CAPACITIES
Length
Facing
Area
Cubic
Capacity
8’
22.2 ft²
38.5 ft³
12’
33.3 ft²
57.7 ft³
The above case model, has case
lengths that are UL and NSF approved.
Kysor//Warren
5201 Transport Blvd
Columbus, GA 31907
800-866-5596 phone
706-568-8990 fax
www.kysorwarren.com
Issue: 3.23.2010
QM3GD - Glycol - Multi-Deck
8’
Applications:
CASE DATA
8’
12’
STD Fan / # of Motors
0.70/2 0.70/2
1.05/3
PSC Fan / # of Motors
0.44/2 0.44/2
0.66/3
ECM Fan / # of Motors
0.60/2 0.60/2
0.90/3
Lighted Shelves (Per row)
Electric Defrost Heater
(Optional 230 V)
0.40
0.50
0.75
5.61
7.93
11.54
All electrical data based on 115V and unlighted
shelves. For lighted shelves, please add 0.25 amps
per shelf.
DEFROST CONTROLS
Defrost
Per Day
Fail Safe
Termination
Electric
4
35 min
48°F
Hot gas
4
20 min
48°F
Off Cycle
4
40 min
48°F
Assorted Shelving Options Available.
Add 3” thickness for a pair of ends.
3 - 12' CASE
1448
963 - 8' CASE
8
1 - 6' CASE
724
213
4
5 STUB UP
58
AREA
101
8
10
22
41
8
587
8
35
1
48
STUB UP
AREA
22
10
71
8
KICKPLATE
LOCATION
DRAIN CONNECTION
(W/TRAP RIGHT OR LEFT)
ELECTRICAL PENETRATION
(TYP)
REFRIGERATION
PENETRATION (TYP)
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such
that conditions do not exceed 75°F and 55% relative humidity. Kysor/Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and
Air Defrost® are registered trademarks of Kysor/Warren®.
CAPACITIES
BTUH per Side (unlighted shelves)
6’
8’
6’
12’
8’
2
STD Fan
5628
7504
11256
Facing Area (per side)
17.8 ft
PSC Fan
5568
7424
11136
Cubic Capacity (per side)
30.2 ft3
ECM Fan
5508
7344
11016
NOTE: For sizing conventional or individual
condensing units, add 8% to BTUH load. For
lighted shelves, add 19 BTUH per FT per
row of lighted shelves.
12’
2
23.8 ft
35.6 ft2
40.3 ft3
60.5 ft3
Evap Temp
Discharge Air Velocity
(1 hr. after defrost)
Discharge
Air Temp
+24°F
250 FPM
+29°F
Issue: 8.24.2011
Kysor/Warren
5201 Transport Blvd
Columbus, GA 31907
800-866-5596 phone
706-568-8990 fax
www.kysorwarren.com
Specification Sheet
503
4
STUB UP
AREA
55
8
213
4
1
78
QM3T - 6’ 8’ 12’ Twin Island
6’
Applications:
Case Data Amps per Side
STD Fan / No. of Motors
0.70/2
PSC Fan / No. of Motors
0.44/2
ECM Fan / No. of Motors
0.60/2
Lighted Shelves (Per row)
0.40
Electric Defrost Heater
5.61
(Optional 230 V)
All electrical data based on 115V and unlighted shelves.
For lighted shelves, please add 0.25 amps per shelf.
DEFROST CONTROLS
Defrost
Per Day
Fail Safe
Termination
Electric
4
35 min
48°F
Hot gas
4
20 min
48°F
Off Cycle
4
40 min
48°F
Assorted Shelving Options Available.
40
20
Add 3” thickness for a pair of ends.
71
8
STUB UP
55
8 AREA
503
4
STUB UP
AREA
35
STUB UP
55
8 AREA
22
1
78
3
ELECTRICAL
PENETRATION (TYP)
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that
conditions do not exceed 75°F and 55% relative humidity. Kysor/Warren®, whose policy is one of continuous improvement,
reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and Air Defrost® are registered trademarks of Kysor/Warren®.
BTUH - 4’ End (unlighted shelves)
STD Fan
5628
PSC Fan
5568
ECM Fan
5508
NOTE: For sizing conventional or individual condensing units, add 8% to BTUH load. For lighted
shelves, add 19 BTUH per FT per row of lighted
shelves.
CAPACITIES — 4’ End
Facing Area
17.8 ft2
Cubic Capacity
30.2 ft3
Evap Temp
Discharge Air Velocity
(1 hr. after defrost)
Discharge Air
Temp
+24°F
250 FPM
+29°F
Issue: 8.24.2011
Kysor/Warren
5201 Transport Blvd
Columbus, GA 31907
800-866-5596 phone
706-568-8990 fax
www.kysorwarren.com
Specification Sheet
79
22
QM3TE - 4’ Island End Case
4 ‘ End
Applications:
CASE DATA AMPS
8’ Side
STD Fan / No. of Motors
0.70/2
0.70/2
PSC Fan / No. of Motors
0.44/2
0.44/2
ECM Fan / No. of Motors
0.60/2
0.60/2
0.40
0.50
5.61
7.93
Lighted Shelves
(Per row)
Electric Defrost Heater
(Optional 230 V)
All electrical data based on 115V and unlighted
shelves. For lighted shelves, please add 0.25
amps per shelf.
DEFROST CONTROLS
Defrost
Per Day
Fail Safe
Termination
Electric
4
35 min
48°F
Hot gas
4
20 min
48°F
Off Cycle
4
40 min
48°F
8’ Cross-Section
See End Case Spec Sheet for End Case Cross-Section.
Assorted Shelving Options Available.
Add 3” thickness for a pair of ends.
Specification Sheet
Plan View
See End Case Spec Sheet for End Case Plan View.
Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such
that conditions do not exceed 75°F and 55% relative humidity. Kysor/Warren®, whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet® and
Air Defrost® are registered trademarks of Kysor/Warren®.
BTUH per Side (unlighted shelves)
CAPACITIES
4’ End
4’ End
8’ Side
2
23.8 ft2
40.3 ft3
8’ Side
STD Fan
5628
7504
Facing Area
17.8 ft
PSC Fan
5568
7424
Cubic Capacity
30.2 ft3
ECM Fan
5508
7344
NOTE: For sizing conventional or individual condensing units, add 8% to BTUH load. For lighted
shelves, add 19 BTUH per FT per row of lighted
shelves.
Evap Temp
Discharge Air Velocity
(1 hr. after defrost)
Discharge Air
Temp
+24°F
250 FPM
+29°F
Issue: 8.24.2011
Kysor/Warren
5201 Transport Blvd
Columbus, GA 31907
800-866-5596 phone
706-568-8990 fax
www.kysorwarren.com
QM3TE - 12’ Twin Island with Unitized End Case
4’ End
Applications:
Case Data Amps per side
End Case Cross-Section
Assorted Shelving Options Available.
8’ Cross-Section
Add 3” thickness for a pair of ends
Kysor/Warren
5201 Transport Blvd
Columbus, GA 31907
800-866-5596 phone
706-568-8990 fax
www.kysorwarren.com
QM3TE
12’ Unitized Island Cross-Section Drawings
12’ Unitized Island Cross-Section Drawings
QM3TE

Similar documents

Q FG T -A - R eac h In - S ta ndard D oor (Anthony ) A

Q FG T -A - R eac h In - S ta ndard D oor (Anthony ) A FLOOR PENETRATION AREA. PLUMBING, ELECTRICAL, & REFRIGERATION LINES.

More information

We Listen, Respond... and Deliver!

We Listen, Respond... and Deliver! All electrical data are based on 115V and unlighted shelves.

More information