clear o3 manual

Transcription

clear o3 manual
WATER PURIFYING SYSTEM
O
D
T
A
O
IF
IED
PAR
M
FRIEN
LY
EC
INSTALLATION MANUAL
U NT C E R
004-027-8780-00 REV040714
US and Foreign patents and patents pending see www.1paramount.com/about/patents/
295 East Corporate Place • Suite 100 • Chandler, AZ 85225
Toll Free: 1.800.621.5886 • Phone: 480.893.7607
Fax: 480.753.3397
[email protected] • www.1Paramount.com
1
CONTENTS
SAFETY INSTRUCTIONS....................................................................................................................... 3
WHAT IS OZONE AND HOW DOES IT WORK............................................................................... 4
SELECTING LOCATION & MOUNTING UNIT................................................................................... 5
MAKING ELECTRICAL CONNECTIONS........................................................................................... 6
ALTERNATE ELECTRICAL CONNECTION FOR
MULTI-SPEED PUMP WITHOUT A CONTROLLER OF TIME CLOCK.................................... 8
MAKING PLUMBING CONNECTIONS...........................................................................................10
OPTIONAL SUBMERGED EQUIPMENT INSTALL.......................................................................13
PLUMBING FOR THE CLEAR03 ......................................................................................................15
USING THE VENTURI INJECTOR METHOD..................................................................................15
SETTING AIR FLOW...............................................................................................................................16
EXTERNAL SAFETY AIR BLEED KIT INSTRUCTIONS (OPTIONAL)......................................16
BULB REPLACEMENT..........................................................................................................................17
TROUBLESHOOTING & SERVICE...................................................................................................19
CLEAR O3 PART NUMBERS..............................................................................................................21
2
SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS: READ COMPLETELY BEFORE
PROCEEDING WITH INSTALLATION. SAVE THESE INSTRUCTIONS
When using this electrical equipment, basic safety precautions should always be
followed, including the following:
CAUTION: READ AND FOLLOW ALL INSTRUCTIONS
WARNING:
• Follow all applicable electrical codes.
• A qualified licensed electrician should perform electrical hookup.
• Turn off power at main source before making any electrical
connections or servicing the unit.
• Use only liquid-tight flexible nonmetallic conduit for electrical
connections.
• A terminal marked G is located inside the supply terminal
compartment. To reduce the risk of electric shock, this terminal must
be connected to the grounding means provided in the electrical supply
service panel with a continuous copper wire equivalent in size to the
circuit conductors supplying this equipment.
• At least one lug marked “BONDING LUG” provided on the external
surface of the unit. To reduce the risk of electric shock, connect the
local common bond grid in the area of the pool or spa to this terminal
with an insulated or bare copper conductor not smaller than 6 AWG.
WARNING:
• ALWAYS wear safety glasses when using power equipment during the
installation process.
• Install at least 5 ft from pool or spa water using nonmetallic plumbing.
Mount ozone generator near pool equipment at least one (1) foot
above maximum water level to prevent water from contacting electrical
equipment. Install in accordance with the installation instructions.
• Short-term inhalation of high concentrations of ozone and long-term
inhalation of low concentrations of ozone gas can cause serious
harmful physiological affects. Do not inhale gas produced by this unit.
If installed in an enclosed space make sure to account for adequate
ventilation.
3
• UV LIGHT PRODUCED BY THIS UNIT IS HARMFUL TO
THE EYES AND MAY CAUSE BLINDNESS. DO NOT LOOK
DIRECTLY AT A LIT BULB!
NOTICE TO INSTALLER/OWNER:
• Save these instructions and deliver to pool owner when installation is
complete.
• Lamp contains mercury. Dispose of in accordance with local and state
regulations.
WHAT IS OZONE AND HOW DOES IT WORK
• O
zone is created from oxygen using a simple yet powerful system of UV bulbs, to
be used as a pure shock (oxidizer) for the swimming pool.
• Ozone is injected into the pool water using the Clear O3® suction injection system,
where the ozone enriched air is mixed with the water going into the pool circulation
pump. This creates a dynamic environment that best mixes the air and water at
high pressure as it is sent into the filter
• Once in the water, the ozone breaks down materials such as ammonia, oils, and
other non-living waste that are detrimental to chlorine’s function in the pool. This
occurs between the pump and filter and also in the filter. Chlorine is in a group
of the least stable elements and must be combined with another material to
become stable. In swimming pools, this process creates the formation of combined
chlorines, like chloramines, which do not sanitize and have adverse effects
on human skin. Use of ozone allows the chlorine to work primarily as a water
disinfectant.
• Pool water treatment can be broken down into three primary categories:
1. D
ISINFECTANT - The killing of living organisms (virus, bacteria, algae). This
consumes only 10-20% of the chlorine normally placed in a pool.
2. O
XIDATION - The removal of non-living waste from pool water. This consumes up
to 70% of the chlorine placed in standard treated pools
3. R
ESIDUAL - The remaining, measurable sanitizer is left in the pool as a safety net
to maintain the water quality until it is brought through the pool equipment again.
Usually less than 10% of the chlorine originally placed in a pool is left over as
residual.
Installing a Clear O3® Water Purification system will reduce the amount of chlorine
needed to maintain a pool by up to70%.
THE BENEFITS OF USING OZONE INCLUDE:
• Fewer chemicals to maintain the pool.
• Less work to maintain the pool water.
• More enjoyable water, being treated similar to bottled water.
• Longer filter cycles, and increased life for the salt chlorinator cells (if present).
4
TO COMPLETE INSTALLATION YOU WILL NEED THE
FOL­LOWING ITEMS (NOT INCLUDED)
(1) Six (6) feet ½" non-metallic conduit outdoor rated.
(1) ½" conduit compression fitting.
SELECTING LOCATION & MOUNTING UNIT
1. S
elect a location on a wall near the pool equipment or insert posts into the ground,
which will be used to hang unit. The Clear O3® unit should be at least one (1) foot
above maximum water level, and for extra safety the unit should be mounted higher
than the filter. The unit should be within five (5) feet of an electrical source, and
within nine (9) feet of plumbing connection. A solid surface is necessary to mount
unit. Mounting brackets are horizontally adjustable to line up with hard points on
the mounting surface. The unit must be mounted horizontally and level on the wall.
Electrical connections should be facing downward.
2. Use provided screws and plastic wall inserts or poles and pole mount clamps
(not included) depending on installation surface available.
3. Four (4) mounting brackets are included (two for the top slot and two for the
bottom slot.
4. Install anchors and screws in desired location for the top hangers. They must be no
further apart than twelve (12) inches. Do not tighten screws all the way. (Fig. 1)
5. Hang the Clear O3® from the two top brackets by sliding the keyhole slots over
the screws.
6. Mark the location for the two bottom brackets. (Fig. 2)
7. R
emove the Clear O3® from the wall and install the wall anchors.
8. Place the Clear O3® unit back on the screws and line up the two lower brackets
with the wall anchors. (Fig. 3)
Fig. 1
9. Install the bottom two screws and
tighten all screws.
12" Maximum
Fig. 2
Fig. 3
5
MAKING ELECTRICAL CONNECTIONS
1. A
licensed electrician should make all electrical connections. Make sure the
unit is grounded by connecting to the pool equipments bond wire to comply
with local electrical codes.
2. Turn off power to the filtration system pump at the circuit breaker.
3. Install an approved seal tight flex conduit (not included) rated for outdoor
use, between the ClearO3 unit and filtration system pump time clock. Feed
the free ends of the wires from the ClearO3 through the conduit and into the
filter system pump time clock or equipment panel (Fig. 5A & 5B). Time clock
or equipment panel must be suitable for field wiring. Electrical connections
should be made in the time clock or equipment panel. NO ELECTRICAL
CONNECTIONS ARE TO BE MADE INSIDE THE CLEARO3!
3.1. The wires from the ClearO3 unit are provided to facilitate connecting to
a panel board that is a maximum of 10 feet away from the unit. If longer
conduit length is needed, then a Listed junction box suitable for the
application may need to be added. All electrical connections need to
be made in accordance with the National Electrical Code.
WARNING:
Turn off power at main source before making any
electrical connections or servicing the unit.
120 Vac 50-60 Hz 0.8A
Fig. 4
WHITE
BLACK
WIRE NUTS
WHITE
230 Vac 50-60 Hz 0.38A
LT GREEN
LT GREEN
BLACK
YELLOW WITH
GREEN STRIPE
WHITE
GREEN
BLACK
LAMP
2X BLUE
OUTPUT
30-60 Vac 700mA - 800mA CLASS P, TYPE
1, RATING: A “RS” ELECTRONIC BALLAST
2X RED
INTERNAL WIRING DIAGRAM OF THE CLEARO3
UNIT. NOT TO BE USED FOR INSTALLATION.
6
Fig. 5A
Fig. 5B
Ground Lug
Fig. 6A
4. Jumper Connections
4.1 C
aution: Be sure of line voltage before
connecting the ClearO3 to the power
source. Connecting the ClearO3 to the
incorrect voltage can cause damage
to the unit. Connect green ground wire
to the time clock ground bar (Fig. 6A).
The Clear O3® unit is set to 240VAC
to be connected to the load side (Fig.
6B) of the filtration pump time clock.
4.2 The ballast may be switched to 120VAC
if the line voltage is 110VAC (Fig. 7A).
4.3 M
ove the black jumper from the
220VAC pins to the 110VAC pins and
the white jumper to the 220VAC pins
(Fig. 7B).
4.4 If you do not have a terminal board and the
inside electrical connections look like (Fig.
8) contact Paramount for instructions on
how to change the voltage.
Fig. 7A
Black Jumper in
220 VAC Pins
Fig. 6A – Wiring connections
to be made inside time clock
or electrical panel.
Fig. 7B
Fig. 6B
Black Jumper in
110 VAC Pins
Fig. 8
Fig. 6B – Wiring connections
to be made inside time clock
or electrical panel.
7
The Clear O3® should run with the filter pump
as the filter pump creates the air draw through
the unit needed to create ozone. Do not set
the Clear O3® to run when the filter pump is
off and not pulling air through the unit.
Fig. 9
5. U
se external ground lug to connect the
Clear O3® to the pool pump ground bond.
Light Blue Glow Tube
(Fig. 5B)
6. Turn on power to filtration system pump.
Check glow tube on the left front of
the Clear O3®. A light blue light indicates lamp is lit and the unit should be
producing ozone. (Fig. 9)
WARNING:
UV light produced by this unit is harmful to the eyes and may cause
blindness! Do not look directly at a lit bulb!
ALTERNATE ELECTRICAL CONNECTION FOR MULTI-SPEED
PUMP WITHOUT A CONTROLLER OF TIME CLOCK
When a pool is built without a controller or time clock for the pump and a variable speed
pump is used the power input is hot all the time. The variable speed pump is turned on and
off by its own internal controller. There is nothing to connect the ClearO3 to (a relay in a
control panel) so it will turn on and off with the pump. When the ClearO3 is installed on these
pools it does not have a way to be turned off when the pump is not operating. These pumps
are available from all the major pool equipment suppliers and several small manufacturers.
Paramount has available an add-on paddle flow switch (Paramount part# 004-402-0010-00
or Grid Controls part # 57-F1-225-00W). The power is run through this switch and then to
the ClearO3. The flow switch is plumbed in the main line of the pool return. When it sees
flow the ClearO3 is turned on.
Fig. 10
breaker panel
Clear03
flow switch
steel tight flex
conduit
8
THE CLEARO3 UNIT IS FACTORY SET TO 240VAC. THE CLEARO3
SHOULD BE WIRED TO RUN WITH THE FILTER PUMP WHICH CREATES
THE AIR DRAW THROUGH THE UNIT NEEDED TO CREATE OZONE. DO
NOT SET THE CLEARO3 TO RUN WHEN THE FILTER PUMP IS OFF.
Fig. 11
Fig. 12
Normally open terminal.
common terminal
Fig. 13
Fig. 14
1. P
lumb the Flow Switch in the main
header after the filter. (Fig.10)
2. A
licensed electrician should make all
electrical connections. Make sure the
unit is grounded by connecting to the
pool equipment bond wire to comply
with local electrical codes.
3. T
urn off power to the filtration system
pump at the circuit breaker. (Fig 11)
4. Install an approved seal tight flex
conduit (not included) rated for
outdoor use between the breaker
panel and the flow switch and between
the ClearO3 and the breaker panel.
(Fig. 10)
5. C
onnect the black leg of the ClearO3
to normally open terminal of the flow
switch. (Fig. 12)
6. C
onnect a black wire to one of the
terminals of the filter pump breaker
and the other end to the power in
(common) terminal of the flow switch.
(Fig. 12)
7. C
onnect the red leg of the ClearO3
to the other terminal of the filter pump
breaker if a 220V circuit (Fig. 13)or to
the common bar in the electrical panel
for a 120V circuit. (Fig. 14)
8. C
onnect the green ground wire from
the ClearO3 to the ground bar in the
breaker panel. (Fig. 14)
9
Fig. 15
9.
se the external ground lug to
U
connect the ClearO3 to the pool
pump bond wire. (Fig. 15)
10. T
urn on power to the filtration
system pump. Check the glow
tube on the left front of the
ClearO3. (Fig. 16) A light blue light
indicates the lamp is lit and the unit
should be producing ozone.
Ground Lug
Fig. 16
NOTE: IF YOU SEE A RED OF
YELLOW LIGHT THRU THE GLOW
TUBE TURN OFF THE POWER
IMMEDIATELY AND REPLACE THE
LAMP. RUNNING THE UNIT WITH
A YELLOW OR RED LIGHT WILL
DAMAGE THE BALLAST.
Light Blue Glow Tube
WARNING:
UV light produced by this unit is harmful to the eyes and may cause
blindness! Do not look directly at a lit bulb!
MAKING PLUMBING CONNECTIONS
1. T
urn off power to the filtration
system pump at the circuit breaker.
2. Pump strainer pot installation: (Fig. 17)
2.1 Check pump elevation above
water level. Refer to (Chart
1)for proper check valve
selection. The 0.5 lb valve
comes standard with Clear
O3® and others are available
to order separately.
2.2 Remove strainer pot plug. If
there is an O-Ring on plug
take O-Ring off of pot plug
and slide over threaded end of
check valve.
Fig. 17
Chart 1
Pump Elevation
Above Water Level
Check Valve
Rating
Part Numbers
1' (30cm)
0.5 lb
005-402-1250-00
2' (60cm)
1.5 lb
005-402-2502-00
4' (120cm)
3.0 lb
005-401-2503-00
5' (150cm)
4.0 lb
005-401-2504-00
10
2.3 W
rap the check valve four
times with teflon tape and
install into the strainer pot
plug-hole. Add more tape if
valve does not seal. (Fig. 18)
2.4 Install the combination needle
valve flow meter on the bottom
of the Clear O3® unit. (Fig. 19)
2.5 Install 3/8" OD x 1/4" ID
tubing to compression end of
check valve. (Fig. 20)
3. P
re-pump standpipe installation:
(Fig. 20 & 21A)
3.1 Cut cap off standpipe.
3.2 G
lue a 3/4" elbow and a 3/4"
x 1/4" NPT reducer bushing on
end of standpipe.
3.3 Install the threaded end of the
check valve included in the
reducer bushing.
3.4 Install 3/8" OD x 1/4" ID
tubing to barbed end of check
valve. (Fig. 20)
Fig. 18
Fig. 19
Fig. 20
NOT TO SCALE
Fig. 21A
2" PIPE
3/4" PIPE
3/4" PIPE
WATER LINE
2" PIPE
3/4" PIPE
WATER LINE
11
4. O
PTIONAL SUBMERGED
EQUIPMENT INSTALLATION
(FIG. 21B)
Fig. 21B
WATER LINE
2-WAY VALVE
To complete this installation option you
will need a two way valve not included.
CLEAR O3
TO SKIMMER
3-WAY VALVE
4.1 Install the two way valve on the
inlet pipe to the pump suction.
(before the standpipe if installed)
4.2 Make all other connections before
the two way valve.
4.3 Make tubing connections to the
pump pot or standpipe as in
standard pump above water level
installation.
4.4 Start the pump with the valve fully
open.
4.5 Note the filter pressure. Then
close the valve slightly until the
pressure on the filter drops two or
three psi.
4.6 Go to setting the airflow on page
19 to finish setting airflow. The
slight restriction this creates on
the pump is the same as if it was
set at approximately one foot
above water level and allows the
pump to draw air in at the pump
pot or standpipe.
(Fig. 21B)
5. L
ay the 3/8 tubing along desired
route to the compression fitting on the
combination needle valve flow meter
on the Clear O3® unit.
6. Connect the tubing to the compression
fitting. (Fig. 22)
7. U
se the provided wires ties to tie
the loose tubing to the conduit or
plumbing. (Fig. 23)
12
TO MDX
*NOT TO SCALE*
CLEAR O3
WATER LINE
2-WAY VALVE
2" PIPE
Fig. 22
Fig. 23
3/4" PIPE
OPTIONAL SUBMERGED EQUIPMENT INSTALL
Fig. 24
2" x 2" x ¾" SLIP TEE
PRESSURE
SIDE FROM
FILTER
- (2) 2” X 2” X ¾” SLIP TEE
- (1) ¾” X ¾” UNION BALL VALVE
- (2) 2” VALVES ¾” FITTINGS AND PIPE
- (2) ¾” UNIONS
SUCTION SIDE
NOTE: ¾” PLUMBING CAN BE 2” IF
NEEDED FOR STRENGTH
Fig. 25A
¾" UNION BALL VALVE
PRESSURE
SIDE FROM
FILTER
SUCTION SIDE
Fig. 25B
VENTURI
PRESSURE
SIDE FROM
FILTER
SUCTION SIDE
New Installation using Paramount venturi
installation kit.
TO COMPLETE THIS INSTALLATION YOU
WILL NEED THE FOLLOWING ITEMS (NOT
INCLUDED)
1. Install two ea. 2" valves, and two each
2" X 2" by ¾" slip tees. One valve and one
slip tee on the suction side of the pump and
one slip tee and valve on the return side of
the pump (before the heater). (Fig. 24)
2. P
lumb ¾" slip tee PVC from pressure side
tee into a union ball valve. (Fig. 25A)
3. P
lumb ¾" PVC from the ball valve into the
inlet side of the venturi (coming from the
return line after the filter before the heater if
it has one.) (Fig. 25B)
4. P
lumb ¾" PVC from the suction side tee
to a ball valve and union and then into the
outlet side of the venturi. Note: The venturi
must be level and removable for cleaning.
The flow arrow on the venturi must point
to show the flow to the suction side of the
pump. (Fig. 25B)
13
Fig. 26A
3/4” PVC
VENTURI
FLO
W
SUCTION SIDE
TO POOL
PRESSURE SIDE
FROM FILTER
Fig. 26B
CHECK VALVE
INSTALLED IN-LINE
5. C
onnect a short piece of 3/8" OD X
¼" ID tubing on the barbed end of the
venturi.
6. C
onnect the ¼" barb in line check
valve to the short piece of tubing. Note:
The correct direction of flow through
the check valve (Fig. 26A & 26B).
7. C
onnect the rest of the 3/8" tubing
to the other end of the barbed in line
check valve.
8. C
onnect the tubing to the compression
fitting. (Fig. 27)
9. C
onnect the compression fitting to the
flow meter. (Fig 28)
SUCTION SIDE
TO POOL
FLOW
3/8” OD X 1/4” IO TUBING
PRESSURE SIDE
FROM FILTER
Fig. 27
NOTE: CLEAR O3 MUST BE
MOUNTED 1' ABOVE WATER
LEVEL
COMPRESSION FITTING
SUCTION SIDE
TO POOL
PRESSURE SIDE
FROM FILTER
Fig. 28
NOTE: CLEAR O3 MUST BE
MOUNTED 1' ABOVE WATER
LEVEL
FLOW METER
SUCTION SIDE
TO POOL
PRESSURE SIDE
FROM FILTER
14
PLUMBING FOR THE CLEAR03
USING THE VENTURI INJECTOR METHOD
The injector manifold must be installed in the pool’s main return line after the pool
filter, heater, chlorinator and spa return. (Fig. 29A) shows the basic installation.
Locate the appropriate section of the return line and install the injector manifold
using PVC primer and glue on all mating surfaces. Glue in a minimum 2” return line.
Water flow arrows on the manifold must be followed and the injector needs to be
facing up with the bypass down. See Fig. 29A & 29B.
The Clear03 ozone suction line will hook directly up to the bottom of the Clear03
and the other end to the injector with the check valve provided with the Clear03. No
flow meter is needed or provided.
NOTE: THE CLEARO3 UNIT MUST BE MOUNTED AT LEAST 1' ABOVE
POOL WATER LEVEL TO PREVENT WATER FROM CONTACTING
ELECTRICAL EQUIPMENT.
CLEAR03
Fig. 29A
CHECK VALVE
RETURN WATER
VENTURI INJECTOR
PUMP
FILTER
HEATER
SUCTION FROM
POOL OR SPA
Fig. 29B
15
SETTING AIR FLOW
Fig. 30
1. Clean
filter and pump basket before setting
airflow.
2. T
urn the knob on the needle valve/flow meter
clockwise to close valve completely.
3. T
urn the power on to the pump.
4. Turn the knob on the needle valve/flow meter
counter clockwise until the ball reads in the
middle of the two lines on the flow meter. (Fig. 30)
NOTE: F
rom time to time condensation may collect in the flow meter, especially
in moist climates or following a rain storm. The moisture may cause the
orange ball to become stuck. The flow meter is not broken. The water will
eventually dry up and the ball will begin to float again. To check draw to
the pump look for air bubbles entering the pump pot.
IMPORTANT NOTES REGARDING THE FLOW METER:
1. IF THE PUMP THAT THE CLEAR 03® UNIT IS INSTALLED ON IS A PUMP
RUNNING A PARAMOUNT IN-FLOOR SYSTEM, lock the water valve on
pause (the pause control is located on top of the Paramount water valve) when
the valve is switching ports and therefore at it’s maximum flow. Set the flow
meter so the ball is on the upper line of the “normal” range.
2. WHEN USING MULTIPLE SPEED PUMPS, SET THE FLOW METER WITH
THE PUMP RUNNING ON THE HIGHEST SPEED THAT WILL BE USED.
3. The Clear O3 flow meter is very sensitive and the red ball may drop down
below the ‘normal’ marker after it has been set. If this happens on your unit,
please be aware that this is normal. The flow meter will still deliver the proper
amount of ozone as long as the blue light is on. You do not need to reset the
flow meter until after you clean your filter.
EXTERNAL SAFETY AIR BLEED KIT INSTRUCTIONS
(OPTIONAL)
Sometimes the internal air bleed on the
filter is not sufficient to handle the extra air
in the system with an ozonator installed.
An External Safety Air Bleed Kit (006-4023872-00) (Fig. 31) for in-ground swimming
pools is available to remove excess air from
the filter and send it downstream (up to 15’)
past all equipment. After installing always
16
Fig. 31
test per instructions that air is vented from the filter when the pump is running. You
must install an external air bleed if the filter is old, does not have an internal air bleed,
there is a solar system on the pool or there is a robotic pressure side cleaner.
MOUNTING INSTRUCTIONS
1. Turn the power off to the pump.
Fig. 32
2. Remove the pressure gauge from
the filter.
2
3
1
3. Install the nipple into one end of
FILTER
HEATER
the brass tee.
CHLORINATOR
4. Install the pressure gauge by
4
threading into the other end of the
brass tee supplied.
FROM
RETURN
BIOSTAT/
PUMP
LINE
BIOCIDE
5. Install the tubing compression
fitting by threading into the side of
Installation of External Safety Air Bleed Kit
the brass tee.
6. Install the tee assembly by
threading into the hole where you removed the pressure gauge (Fig. 32).
7. Insert one end of the tubing into the compression fitting (Fig. 32).
8. Turn the power on to the pump and check that air is coming from the other end of
the tubing.
9. Turn the power off to the pump.
10. Pick a spot on the return pipe downstream of all other devices (heater,
chlorinator, pressure cleaner, etc.)
11. Drill a 7/16” hole through the return pipe at the location selected.
12. Install the saddle clamp with the fitting over the hole. Make sure the gasket is in
place between the fitting and the pipe. (Fig. 32)
13. Lay the tubing along the return pipe to the saddle clamp fitting and cut off
excess length.
14. Connect the end of the tubing to the compression fitting on the saddle clamp
(Fig. 32). The tubing can be secured to the pipe using cable ties (not included).
BULB REPLACEMENT
NOTE:
Ozone production from direct UV light will decline over time. UV bulbs continue
to illuminate after they stop producing an effective level of ozone to clean your
pool water. To make sure your pool continues to receive all the benefits of ozone,
Paramount recommends that you replace your bulb every three (3) years.
WARNING:
• Turn off power at main source before making any electrical connections
or servicing the unit.
• UV light produced by this unit is harmful to the eyes and may cause
blindness! Do not look directly at a lit bulb!
17
1.
2.
3.
4.
5.
6.
7.
8.
Turn the power off to filtration system pump at circuit breaker.
Remove three screws in left end side cap labeled “electrical connections”. (Fig. 33)
Remove side cap. (Fig. 34)
Grasp light bulb plug and pull light out about one inch. (Fig. 35)
Remove plug from light bulb. (Fig. 36)
Pull light bulb free from Clear O3® unit. (Fig. 37)
Make sure gasket is in place on replacement light bulb.
Align with key and slide into hole until bulb seats firmly and completely into unit.
(Fig. 38)
9. Press plug onto light bulb.
10. Replace side cap and three screws.
11. Turn on power to filtration system pump.
12. Check glow tube on the left front of the Clear O3®. A light blue light indicates
lamp is lit and the unit should be producing ozone.
Fig. 33
Fig. 36
Fig. 34
Fig. 37
Fig. 35
Fig. 38
18
TROUBLESHOOTING & SERVICE
ISSUE
SOLUTION
No air bubbles entering system or pool
Clean filter then adjust airflow needle
valve
Filter empties and pump loses prime
Replace check valve fitting at strainer pot
Light bulb does not light
Check power to Clear O3®, then
replace bulb
19
3
1
2
4
5
8
7
11
12
6
9
10
15
13
14
16
18
(optional)
(optional)
19
(optional)
17
(optional)
20
(optional)
20
CLEAR O3 PART NUMBERS
ITEM PART NUMBER
DESCRIPTION
SINGLE UNIT
1.
004-402-3880-00
Clear O3® Single Assembly
2.
005-402-3834-00
Lamp
3.
005-402-3820-00
Mounting Brackets (4Pk)
4.
**
Ground Lug
5.
005-402-1384-00
Conduit Compression Fitting 1/2"
6.
**
Wiring Harness 3-Wire 12 Gauge x 6'
7.
005-402-3361-00
Tubing With Check Valve Pump Mount, & Wire Ties
8.
**
Tubing 3/8" OD x 1/4" ID x 10'
9.
**
Pump Mount Check Valve 1/4" NPT x barb
10.
**
Wire Ties (4Pk)
11.
005-402-3247-00
Flow Meter Kit
12.
**
Compression Nut 1/4" x 3/8"
13.
**
Anchor #10
14.
**
Screw: 10 x 3/4" PHIL PH
15.
005-402-1050-00
Clear O3 Adapter Pot Plug (Optional)
16.
005-402-3824-00
Ballast & Filter
AIR BLEED
17.
006-402-3872-00
Clear O3 Air Bleed Kit (Optional)
18.
005-252-3250-00
Venturi Injector Kit (Optional)
19.
005-402-1242-00
Check Valve In-line Barb for Venturi Installations
20.
004-402-3873-00
Pressure Side Mazzie Injector Manifold
** Not available to purchase individually
21
22
U.S. and Foreign patents and patents pending go to: www.1paramount.com/about/patents/
004-027-7997-00
REV060914
Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitations or exclusions may not apply to you. Implied warranties
are limited in duration to the duration of the written limited warranty here within. Some
states do not allow limitations on how long an implied warranty lasts, so the above
limitations may not apply to you. This warranty gives you specific legal rights, and you
may also have other rights that may vary from state to state.
No warranty extends to any part of the PP&SS parts or components which is caused by
any of the following conditions or events:
1. Defects or failures caused by abuse, lack of responsible care, lack of necessary
maintenance, improper operation, vandalism, acts of God.
2. Damages or failures caused by abuse, lack of responsible care, lack of necessary
maintenance, improper operation, vandalism, acts of God.
3. PP&SS expressly denies any responsibility or liability for incidental or
consequential damages arising out of, or as a result of, use or ownership of
your PP&SS parts or as a result of use or ownership of your PP&SS parts or
components, or other related products covered under this limited warranty.
4. Any defects caused by acts of God, such as storms, earthquakes, ground
movement, or freezing, etc., that are beyond the normal conditions.
5. Installation of the PP&SS System by a non-authorized installer may render this
warranty null and void.
LIMITATIONS
Paramount Pool & Spa Systems (PP&SS) | 295 E. Corporate Place, Suite 100 | Chandler AZ 85225 | 1.800.621.5886 | 1Paramount.com
Contact PP&SS for an RMA number, and return it to PP&SS. Ship part in question freight
pre-paid, and upon confirmation of defect, PP&SS will repair or replace the PP&SS
warranted item at no charge to the original owner. The repaired or replaced PP&SS item will
be returned to the original owner with the return freight paid by original owner. Labor to reinstall the repaired or replaced item is the sole responsibility of the owner.
REPLACEMENT CONDITIONS
Replacement parts are warranted for a period of one (1) year from date of purchase and
are not sold with any field service program.
This limited warranty shall be subject to the original owner complying with the following
conditions:
PP&SS warrants to original owner, materials, and equipment to be free of defects for a
period of two (2) years from the date of swimming pool start-up or retail purchase. The
materials, parts and/or related component parts supplied or distributed by PP&SS are
covered under this two (2) year limited warranty. (PVC plumbing installed, labor, material
and all other work performed by contractors is not covered under PP&SS Warranty.)
PP&SS offers in field warranty service through a network of authorized Warranty Service
Stations (W.S.S.) for one (1) year from the date of swimming pool start up or retail
purchase. This warranty service must be arranged through your builder or retailer with
Paramount. There is no reimbursement for any labor charges incurred outside of the
Paramount W.S.S. network.
CONDITIONS
In compliance with the Magnuson-Moss Warranty-Federal Trade Commission Act (Public Law
930637, Paramount Pool & Spa Systems (PP&SS) provides the following limited warranties.
Clear O3TM Warranty Certificate
WARRANTY REGISTRATION
A one (1) year warranty on Clear O3®
parts shall be subject to the original
owner, as stated in the “Other Related
System Parts and Replacement Parts
Limited Manufacturer’s 1-Year Warranty.”
POOL OWNER INFORMATION
Name:
Address:
Cut Here and Return to Paramount
City:
State:
Zip Code:
Telephone:
Fax:
E-mail:
Pool Start-Up Date Purchased:
Type of Pool (check one):
Concrete
Vinyl
Fiberglass
Type of Pool System (check one):
PCC 2000
PV3
Cyclen
Vanquish
Vantage
EcoPool
POOL BUILDER INFORMATION
Name:
Address:
City:
State:
Zip Code:
When complete, remove this page, fold, stamp and return to
Paramount Pool & Spa Systems.
295 East Corporate Place, Suite 100 • Chandler, AZ 85225
Fax: 480.753.3397
E-mail: [email protected]
Web: www.1Paramount.com/products/warranty.php
Pool Valet
Place
Stamp
Here
Paramount Pool & Spa Systems
295 East Corporate Place, Suite 100
Chandler, AZ 85225
Staple Here
Cut Here and Return to Paramount
Fold Here