Accessories Catalog - Bio

Transcription

Accessories Catalog - Bio
EC-lab products
Electrochemistry
accessories
Analytical cell
Corrosion cell
Glassware
Electrodes
Rotating electrodes
Spectroelectrochemistry
Quartz crystal analyzer
Battery accessories
Fuel cell
Connection accessories
Bio-Logic
Bio-Logic SAS (founded in 1983)
is located near Grenoble
in the French Alps.
We design and manufacture
high performance, research
laboratory instruments for
electrochemistry, battery testing
and fuel cell testing.
Bio-Logic’s product range is
based on a modular and flexible design.
We offer potentiostat workstations
from single channel up to
16 channel systems, integrating
EIS capability and high current
boosters.
Analytical
Small volume cells
Large volume cells
Flow cells
InterDigitated Array (IDA) electrodes
Ring disk type electrodes
Screen Printed Electrodes (SPE)
Corrosion
Standard corrosion cells
Avesta cell
Flat cells
Galvanic cells
Plate material evaluating cell
Coating cell
10
11
12
13
13
13
Glassware
Small & big volume cell vials
Bridge & purge tubes for corrosion cells
Small size bridge tubes
Bridge & purge tubes for analytical cells
Bridge tubes with ceramic junction
14
16
16
17
18
Electrodes
Working electrodes
Small size reference electrodes
King size reference electrodes
Counter electrodes
Metallic electrodes
18
20
22
23
23
Rotating
Rotating Ring Disk Electrode (RRDE)
Working electrode tips
Rotating Disk Electrode (RDE)
24
25
26
Spectro-
Spectrometer
Static experiment
Flow experiment
Thin layer spectroelectrochemical cell 28
30
31
32
Quartz
EQCM
Quartz resonators
Biosensor QCM
34
35
36
Battery
Test cells
Dilatometers
Rack
Battery (BH-1) & Coin Cell Holder (CCH)
Current Collector (CC5)
Sense Adapter Module (SAM-50)
38
39
40
40
41
41
Fuel
Membrane Electrode Assemblies (MEA)
Educational kit
42
43
Connection
Multi-electrode investigation cables
Specific cables
External device connection
Test Boxes & Dummy cells
Faraday cages
Connectors
Transport cases
44
45
45
46
46
47
47
crystal analyzer
accessories
ELECTROCHEMISTRY accessories
cell
Analytical
cell
Corrosion
Glassware
Electrodes
Rotating
electrodes
electrochemistry
Spectro-
accessories
accessories
Connection
cell
Fuel
cell
crystal analyzer
electrochemistry
Quartz
electrodes
accessories
cell
Battery
cell
4
6
7
8
8
9
2/3
Analytical cell
SVC-2
Small volume cells
Each voltammetry cell
is designed for a
specific application
(specific working
electrode, volume of
solution, oxygen free
condition...).
SVC-3
For example, for voltammetry investigations using standard working
electrode with an outer diameter (OD) of 6 mm the fixed configuration
of SVC-3 kit is recommended.
For application requiring other working electrode shape, SVC-2 is
more suitable.
If only a small amount of the electroactive compound is available,
SVC-2 in the microvolume mode is recommended.
- SVC-2, modular
- SVC-3, for a volume of 5 to 20 mL, only for working electrode with OD of 6 mm.
- VC-4, for a volume of 1 to 3 mL, only for working electrode with OD of 6 mm.
- Bulk electrolysis cell, for a volume of 100 mL.
SVC-2 modularity:
microvolume mode
oxygen free mode
Small amount of solution
(200 μL in the sample holder)
For electrode
with OD of 10 mm
For electrode
with OD of 6 mm
For microelectrode
with OD of 4 mm
Note that a complete analytical special kit SK-2
(A-012763) is also proposed, but the reference
electrode has to be purchased separately.
This kit includes:
- SVC-3 kit (A-012669),
- PK-3 polishing kit (A-011975) (see page 18),
- one glassy carbon electrode, OD 6.0 mm,
ID 3.0 mm (A-002012) (see page 18),
- one platinum electrode, OD 6.0 mm,
ID 1.6 mm (A-002013) (see page 18).
30
20
10
I/nA
0
-10
-20
-30
-40
-50
-0.5
0
Ewe/V
0.5
cell
Analytical
Glassware
cell
Corrosion
Cell holder
Purge tube (ETFE)
Working electrodes
Reference electrodes
VC-4
A-011224
Bulk electrolysis cell
A-001197
20 mL
(7 pieces)
57 mm
A-001056
20 mL
(7 pieces)
50 mm
A-001056
5 mL
(7 pieces)
57 mm
A-011504
100 mL
(1 piece)
230 mm
A-012632
adapter
10 to 6
-
cell holder
A-011227
porous carbon electrode
lid for CE
chamber for CE
O-ring
port plug
stirrer bar
A-010530
A-001198
A-001196
A-001236
A-009131
A-000178
9.0 mm
(2 pieces)
for 20 mL
1m
A-012177
1m
see page 18
see page 20
A-010537
1m
A-010537
PTFE cap
A-001209
A-010537
6.0 mm
(2 pieces)
for 20 mL
1m
see page 18
see page 20
A-002222
A-011226
-
A-002234
A-0 12551
-
Rotating
A-002222
A-012671
-
electrodes
A-002222
A-012670
-
Electrodes
Catalog n°
A-012669
electrochemistry
Options
Sample holder
Catalog n°
SVC-3
A-012176
A-001209
A-010537
see page 20
10.2 mm
6.2 mm
1.65 mm
1.6 mm
1.6 mm
6.3 mm
6.2 mm
crystal analyzer
Counter electrode (CE)
PTFE cap
Purge tube (ETFE),
100 mm
Additional items
Catalog n°
A-012668
Quartz
Content
Sample vial
Catalog n°
SVC-2
1.6 mm
accessories
Products
Battery
Small volume cells
Bulk electrolysis cell
Spectro-
VC-4
Cell geometry
The geometry of the cell should be optimized to reduce the ohmic drop.
Working and reference electrodes have to be close to each other.
accessories
Connection
cell
Fuel
The counter should not be the limiting factor for the electron transfer,
so the surface area of the counter electrode should be larger than the
surface area of the working electrode.
ELECTROCHEMISTRY accessories
4/5
Analytical cell
Large volume cells
This analytical cell with volumes
from 50-250 mL is well adapted
for macro electrochemistry
applications.
Two types of packages are offered:
- the standard analytical cell kit,
- the complete analytical cell kit
(which allows temperature
control and gas purging).
Standard
analytical
cell kit (80 mL)
EL-ELECTRO-1
Complete
analytical
cell kit (80 mL)
EL-ELECTRO-2
Complete
analytical
cell kit (150 mL)
EL-ELECTRO-3
Glass cell 80 mL
Double jacketed glass cell 80 mL
Double jacketed glass cell 150 mL
PTFE cap 5 holes
PTFE ring, silicon encapsulated, OD 102 mm
Cell collar with clamp
Double purge tube
Bridge tube for reference electrode, OD 6 mm
Platinum counter electrode
Purge tube
Reference electrode
Double nut 25 mm and 12 mm diameter
Telescopic cell stand
Options
Electrode bridge extension for electroanalytical cell
Bridge tube for reference electrode of OD 8 mm
PT100 probe, indicate connector type
Magnetic stirrer & heater,
220 V
without PT100 probe
110 V
Aluminum base holder for magnetic stirrer
Set of 10 porous 4 mm glass frit (CoralPor™) with PTFE heat shrink (200 mm)
250 mL cells are also available: g lass cell EL-A-018 or
double jacketed glass cell EL-A-021
EL-A-012
EL-A-002
EL-A-003
EL-A-004
EL-A-005
Catalog n°
EL-A-001
EL-A-002
EL-A-020
EL-A-003
EL-A-004
EL-A-005
EL-A-006
EL-A-008
EL-A-009
EL-A-016
A-002056
EL-A-011
EL-A-012
EL-A-022
EL-A-017
EL-C-014
EL-C-015A
EL-C-015B
EL-C-018
092-VYC4
EL-A-008 EL-A-009
EL-A-022
cell
Analytical
Catalog n°
A-012798
Radial flow cell
OUTLET
flow channel
OUTLET INLET
INLET OUTLET
detector
Catalog n°
A-012799
Radial flow cell*
Schematic
diagram
gasket
Glassware
cell
Corrosion
Cross flow cell*
gasket
Rotating
Cross flow cell
Product
electrodes
Flow cells
Electrodes
Radial flow cell
Cross flow cell
detector
* Gasket, working, reference electrodes and connectors are sold separately
ELECTROCHEMISTRY accessories
electrochemistry
Spectro-
crystal analyzer
Quartz
accessories
Battery
cell
Dual, parallel/cross flow
A-001000
A-001002
A-001012
A-001008
A-001004
A-001009
A-001006
A-012583
A-001046
A-001047
A-001048
A-001049
A-001092
A-001093
A-001032
A-001016
A-012124
A-009908
A-011155
A-000999
A-010251
A-001146
A-001147
A-001148
A-012802
A-001192
A-001193
A-001031
A-012169
A-012173
A-012170
A-012174
A-012912
A-013273
A-001531
A-004130
Fuel
Dual, series/cross flow
glassy carbon
Ø 3 mm x 2 (dual type), size 25 x 25 mm
gold
Ø 3 mm x 2 (dual type), size 25 x 25 mm
platinum
Ø 3 mm x 2 (dual type), size 25 x 25 mm
silver
Ø 3 mm x 2 (dual type), size 25 x 25 mm
carbon paste
Ø 3 mm x 2 (dual type), size 25 x 25 mm
nickel
Ø 3 mm x 2 (dual type), size 25 x 25 mm
glassy carbon/gold
Ø 3 mm x 2 (dual type), size 25 x 25 mm
glassy carbon/platinum
Ø 3 mm x 2 (dual type), size 25 x 25 mm
gasket
TG-2M PTFE (4 pieces)
film thickness 12 µm
TG-5M PTFE (4 pieces)
film thickness 25 µm
TG-6M PTFE (4 pieces)
film thickness 50 µm
TG-8M PTFE (4 pieces)
film thickness 100 µm
TG-11M silicon (4 pieces)
film thickness 500 µm
TG-12M silicon (4 pieces)
film thickness 1,000 µm
cross flow cell block
material PEEK
Radial flow electrode glassy carbon
Ø 6 mm (single type), size 25 x 25 mm
glassy carbon
Ø 3 mm (single type), size 25 x 25 mm
platinum
Ø 3 mm (single type), size 25 x 25 mm
gold
Ø 3 mm (single type), size 25 x 25 mm
PFCE carbon
Ø 3 mm (single type), size 25 x 25 mm
carbon paste
Ø 3 mm (single type), size 25 x 25 mm
gasket
TG-2MR PTFE (4 pieces)
film thickness 12 µm
TG-5MR PTFE (4 pieces)
film thickness 25 µm
TG-6MR PTFE (4 pieces)
film thickness 50 µm
TG-8MR PTFE (4 pieces)
film thickness 100 µm
TG-11MR PTFE (4 pieces)
film thickness 500 µm
TG-12MR PTFE (4 pieces)
film thickness 1,000 µm
radial flow cell block
material PEEK
Cross/radial RE-3V Ag/AgCl reference electrode screw type size Ø 10 x 48 mm
RE-7V non aqueous reference electrode (Ag/Ag+) screw type, poly acetal resin
RE-3VP Ag/AgCl screw type electrode, PEEK resin
RE-7VP non aqueous reference electrode (Ag/Ag+) screw type, PEEK resin
0.04" single leal connector (2 pieces)
0.04" MM connector (10 pieces)
1/16" PEEK tube
ID 0.25 mm, length 3.0 m
dynaseal PEEK fingertight (10 pieces)
screw for pipe connecting integrated 1/16"
accessories
Single/radial flow
electrode
Connection
Options
Cross flow
6/7
Analytical cell
3 µm
InterDigitated Array (IDA) electrodes
2
Counter electrode
Passivation membrane
20
Reference electrode
Working electrode #1
Working electrode #2
Quartz plate,
thickness = 0.5 mm
12
The passivation membrane is a
Novolac resin + naphtoquinorediazido compounds.
10 µm
IDA electrode
Width
Interval Length
N° of feet
Film thickness
Catalog n°
Gold
Platinum
Gold without passivation membrane
Platinum without passivation membrane
Gold
Platinum
Gold without passivation membrane
Platinum without passivation membrane
Gold
Platinum
ITO
Carbon
Gold without passivation membrane
Platinum without passivation membrane
ITO without passivation membrane
Carbon without passivation membrane
2 µm
2 µm
2 µm
2 µm
3 µm
3 µm
3 µm
3 µm
10 µm
10 µm
10 µm
10 µm
10 µm
10 µm
10 µm
10 µm
2 µm
2 µm
2 µm
2 µm
3 µm
3 µm
3 µm
3 µm
5 µm
5 µm
5 µm
5 µm
5 µm
5 µm
5 µm
5 µm
65 pairs
65 pairs
65 pairs
65 pairs
65 pairs
65 pairs
65 pairs
65 pairs
65 pairs
65 pairs
65 pairs
65 pairs
65 pairs
65 pairs
65 pairs
65 pairs
90 nm
90 nm
90 nm
90 nm
90 nm
90 nm
90 nm
90 nm
90 nm
90 nm
100 ±20 nm
1200 ±100 nm
90 nm
90 nm
100 ±200 nm
1200 ±100 nm
A-012257
A-012258
A-012261
A-012264
A-012129
A-012130
A-012260
A-012263
A-012125
A-012126
A-012128
A-012127
A-012259
A-012262
A-012265
A-012266
2 mm
2 mm
2 mm
2 mm
2 mm
2 mm
2 mm
2 mm
2 mm
2 mm
2 mm
2 mm
2 mm
2 mm
2 mm
2 mm
Options
Cable kit for IDA electrode
Ag/AgCl ink for reference electrode (2.0 mL)
A-011066
A-011464
Ring disk type electrodes
Ring disk type electrodes
Ring OD
Ring ID
Disk
Catalog n°
Gold ring disk electrode (3 pieces)
Platinum ring disk electrode (3 pieces)
Carbon ring disk electrode (3 pieces)
6 mm
6 mm
6 mm
4 mm
4 mm
4 mm
3 mm
3 mm
3 mm
A-002081
A-002082
A-002083
cell
Analytical
cell
Corrosion
Screen Printed Electrodes (SPE) are low cost and
disposable. They include one reference electrode,
one counter electrode and one or several working
electrodes according to the design needed. The
working electrode can be made of glassy carbon,
platinum, gold. The SPE allows users to work with
a small amount of solution (25-100 μL).
Glassware
Screen Printed Electrodes (SPE)
Electrodes
U-GEM,
connector for
3-electrode SPE
Counter electrode
Reference electrode
Rotating
Working electrode
Packaging
Catalog n°
alumina
alumina
valox FR1
valox FR1
alumina
alumina
valox FR1
valox FR1
alumina
alumina
valox FR1
valox FR1
100 pieces
500 pieces
100 pieces
500 pieces
100 pieces
500 pieces
100 pieces
500 pieces
100 pieces
500 pieces
100 pieces
500 pieces
G-GGA/1
G-GGA/2
G-GGP/1
G-GGP/2
G-PTGA/1
G-PTGA/2
G-PTGP/1
G-PTGP/2
G-AUGA/1
G-AUGA/2
G-AUGP/1
G-AUGP/2
Option
Connector for 3-electrode Screen Printed Electrodes (2 mm banana plug)
Ø of WE:
size of pseudo-RE:
overall dimension:
0.8 mm
20 x 1 mm
45 x 19 mm
ELECTROCHEMISTRY accessories
Working electrode
Counter electrode & ref. electrode
Substrat
Packaging
Catalog n°
graphite
graphite
graphite
graphite
platinum
platinum
platinum
platinum
gold
gold
gold
gold
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
alumina
alumina
valox FR1
valox FR1
alumina
alumina
valox FR1
valox FR1
alumina
alumina
valox FR1
valox FR1
100 pieces
500 pieces
100 pieces
500 pieces
100 pieces
500 pieces
100 pieces
500 pieces
100 pieces
500 pieces
100 pieces
500 pieces
G-A-GA/1
G-A-GA/2
G-A-GP/1
G-A-GP/2
G-A-PTA/1
G-A-PTA/2
G-A-PTP/1
G-A-PTP/2
G-A-AUA/1
G-A-AUA/2
G-A-AUP/1
G-A-AUP/2
cell
Array of 16 WE
U-GEM
Fuel
Ø of WE: 2 mm
size of RE:
0.5 x 1 mm
ratio CE/WE surface area:4/1
overall dimension:
50 x 10 mm
electrochemistry
Substrat
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
Ag/AgCl
crystal analyzer
Ref. electrode
graphite
graphite
graphite
graphite
graphite
graphite
graphite
graphite
graphite
graphite
graphite
graphite
Quartz
Counter electrode
graphite
graphite
graphite
graphite
platinum
platinum
platinum
platinum
gold
gold
gold
gold
accessories
Working electrode
3-electrode
Battery
Screen Printed Electrodes
Spectro-
Array of 16 working electrodes
accessories
Three-electrode sensor
Connection
Note with Bio-Logic’s multichannel potentiostats,
it is possible to run simultaneous investigations
on each working electrode of the array (up to 16).
electrodes
A two–electrode set-up is used for multi working
electrode SPE with one shared reference electrode
and one shared counter electrode.
8/9
Corrosion cell
Standard corrosion cells
For corrosion applications,
two packages for large volume
i.e. ~1 L are available:
- basic corrosion cell kit,
- complete corrosion cell kit
(allows temperature control
and includes sample holder
and cell stand).
Basic corrosion
cell kit
EL-CORR-1
Complete
corrosion cell kit
EL-CORR-2
Options
Bridge tube for 6 mm diameter reference electrode
PT100 probe (indicate connector type)
Magnetic stirrer & heater, without PT100 probe
Catalog n°
EL-C-001
EL-C-002
EL-C-003
EL-C-004
EL-C-005
EL-C-006
EL-C-009
EL-C-011
EL-C-012
092-C-013
EL-C-016
EL-C-017
R-XR110
R-A94L111
R-X31M012
Glass cell 1 L
Double jacketed glass cell 1 L
PTFE cap
PTFE ring, silicon encapsulated, OD 102 mm
Cell collar with clamp
Double purge tube
Graphite counter electrode rod (2 pieces)
Double nut 25 mm and 12 mm diameter
Telescopic cell stand
Sample holder 1 cm2
Purge tube
Bridge tube for 8 mm diameter reference electrode
Calomel reference electrode length 80 mm, OD 8 mm screw cap
Cable connection for screw cap 100 mm, 2 mm banana plug
12 mm OD conical rings for reference electrode of 8 mm (4 pieces)
EL-C-008
EL-C-014
EL-C-015A
EL-C-015B
EL-C-018
092-VYC4
220 V
110 V
Aluminum base holder for magnetic stirrer
Set of 10 porous frit (4 mm CoralPor™) with PTFE heat shrink (200 mm)
500 mL or 2 L double jacketed glass cell
are also available (EL-C-020 and EL-C-021, respectively).
092-C-013
8
log (|I/nA|)
7
6
EL-C-002
5
4
3
-0.6
-0.4
0
-0.2
Ewe/V
0.2
EL-C-003
EL-C-004
EL-C-005
EL-C-017
EL-C-009
cell
Analytical
cell
Corrosion
Glassware
Electrodes
Avesta cell
Avesta cell is an electrochemical cell developed
for pitting corrosion testing (ASTM G150).
It is designed to avoid microcrevice corrosion
formed between the working electrode and the
gasket at the bottom aperture of the cell.
electrodes
Rotating
A filter paper ring placed between the sample
and the gasket is flooded by distilled water
in order to eliminate crevice corrosion.
Options
Peristaltic pump for low flow
Bridge tube for reference electrode
with OD of 8 mm
Single purge tube
Temperature probe PT100
Set of 10 porous frit (4 mm CoralPor™)
with PTFE heat shrink (200 mm)
Spectro-
EL-AV-002
EL-AV-003
EL-AV-004
EL-A-005
EL-AV-006
EL-AV-007
EL-C-009
EL-AV-010
EL-C-011
EL-AV-012
EL-AV-015
crystal analyzer
Content
Double jacketed cell glass 250 mL
PTFE cap 5 holes
O-ring PTFE silcone encapsulated
Cell collar with clamp
Double purge tube
Filter paper ring (100 pieces)
Graphite counter electrode rods (2 pieces)
Bridge tube for RE 6 mm
Double nut
Telescopic cell stand
Skeleton
Quartz
EL-AV-001
accessories
Catalog n°
Avesta cell kit
Battery
Avesta cell
electrochemistry
The water flow is controlled by a peristaltic pump
(EL-AV-008) which delivers 0.5 to 5 mL/h.
EL-AV-008
EL-AV-013
EL-AV-014
EL-C-014
092-VYC4
Fuel
Principle of Avesta cell
Connection
cell
External gasket
Filter paper ring
Internal gasket
INLET
ELECTROCHEMISTRY accessories
accessories
Sample
Copper
connector
10/11
Corrosion cell
Flat cells,
1 to 10 cm² sample area
This cell with a volume of 250 mL is
adapted to perform AC or DC experiments
on flat specimen of 1 cm² or 10 cm² area.
This cell has a double jacket for temperature
control and three holes for reference electrode,
purge tube and temperature probe with inner
diameter of 17.6 mm and the 2 others of 8.3 mm.
Thanks to its design, any sample with a thickness
inferior to 10 mm fits in the holder.
Flat cell 1 cm²
Catalog n°
Flat cell 10 cm²
Catalog n°
Flat cell kit 1 cm²
EL-FLAT
Flat cell kit 10 cm²
EL-FLAT-2
Content
RE-2B calomel reference electrode
(length: 90 mm, OD: 6 mm)
Platinum mesh counter electrode
(54 mm wire/ 80 mesh), 25 x 35 mm
Reference electrode bridge tube
(6 mm diameter)
Corrosion flat cell 1cm²
EL-FLAT-3 includes:
- glass part for flat cell (250 mL)
- mechanical part for corrosion
flat cell 1 cm²
A-002056
A-702439
EL-F-004
EL-FLAT-3
EL-F-002
EL-FLAT-3H
Content
RE-2B calomel reference electrode
(length: 90 mm, OD: 6 mm)
Platinum mesh counter electrode
(54 mm wire/ 80 mesh), 25 x 35 mm
Reference electrode bridge tube
(6 mm diameter)
Corrosion flat cell 10 cm²
EL-FLAT-4 includes:
- glass part for flat cell (250 mL)
- mechanical part for corrosion
flat cell 10 cm²
A-002056
A-702439
EL-F-004
EL-FLAT-4
EL-F-002
EL-FLAT-4H
Investigation in agressive media
If the experiment is performed in more agressive media such as fluorhydric acid media,
it is possible to get a body of the flat cell in PVDF* instead of glass.
Temperature
PTFE
PVDF*
Borosilicated glass
Fluorhydric
acid 48%
Sulfuric
acid 98%
Phosphoric
acid 85%
Hydrochloric
acid 35%
Nitric
acid 70%
Perchlorique
acid
20° C
20° C
20° C
20° C
20° C
20° C
50° C
50° C
50° C
50° C
Catalog n°
Options
PVDF* body (non double jacketed)
EL-F-PVDF
EPDM O-rings for 1 cm² with PEEK ferrule for CE**
EL-SEAL-1B
EPDM O-rings for 10 cm² with PEEK ferrule for CE**
EL-SEAL-10B
PTFE O-rings for 1 cm² with PEEK ferrule for CE**
EL-SEAL-T1B
PTFE O-rings for 10 cm² with PEEK ferrule for CE**
EL-SEAL-T10B
EPDM O-rings for 1 cm²**
EL-SEAL-1
EPDM O-rings for 10 cm²**
EL-SEAL-10
PTFE O-rings for 1 cm²**
EL-SEAL-T1
PTFE O-rings for 10 cm²**
EL-SEAL-T10
Set of 10 porous frit (4 mm CoralPor™) with PTFE heat shrink (200 mm)
092-VYC4
* Polyvinylidenefluoride
** The O-ring kits include 4 O-rings for the glassware side and 10 O-rings for the sample side
50° C
50° C
Sodium
Potassium
hydroxide 50% hydroxide
concentred
20° C
50° C
*
20° C
50° C
excellent
good
not recommended
not compatible
Polyvinylidenefluoride
cell
Analytical
cell
Corrosion
Glassware
Galvanic cell 1 cm²
Catalog n°
Galvanic cell 10 cm²
Catalog n°
Galvanic cell kit 1 cm²
EL-GAL-1
Galvanic flat cell kit 10 cm²
EL-GAL-10
EL-FLAT
092-FLAT/1
Content
Flat cell kit 10 cm²
Galvanic kit 10 cm²
EL-FLAT-2
092-FLAT/10
Content
Flat cell kit 1 cm²
Galvanic kit 1 cm²
Rotating
Thanks to the modular
design of the flat cell,
it is possible to place
two different materials
at each end of the cell.
Electrodes
Galvanic cells,
1 to 10 cm² sample area
Spectro-
electrochemistry
electrodes
The surface area may
be 1 or 10 cm².
Plate material evaluating cell
Catalog n°
A-011951
Content
PTFE cell [body & base] (1 piece)
O-ring (1 piece)
Screw 20 mm (1 piece)
Purging tube, 100 mm
Platinum counter electrode (1 piece)
A-002222
Options
O-ring (10 pieces)
A-012022
ELECTROCHEMISTRY accessories
Options
Ag/AgCl reference electrode (OD: 6mm)
Bridge tube for 6 mm reference electrode
Mask for 1 cm² (20 pieces)
Mask for 5 cm² (20 pieces)
Mask for 10 cm² (20 pieces)
crystal analyzer
Quartz
EL-P-002
EL-P-003
EL-P-004
EL-P-005
EL-P-006
EL-P-009
accessories
Battery
Content
Glass for coating cell
Nylon base with three feets
Rubber cup with two holes
Metallic clamp
O-ring for coating cell
Graphite rod counter electrode
(L: 145 mm, OD: 6 mm)
Catalog n°
EL-COAT
A-012167
EL-P-008
EL-P-011
EL-P-012
EL-P-013
cell
Plate material evaluating cell
Coating cell kit
Fuel
The required volume of solution is about 1 mL.
Coating cell
accessories
This cell was developed to evaluate a plate material
such as a metal, semi-conducting plate...
The sample plate is sandwiched between the two
cell blocks.
Coating cell
Connection
Plate material
evaluating cell,
up to 1 cm² sample area
12/13
Glassware
Small volume cell vials,
1 to 100 mL
To complete a kit,
the cell vials are also
offered separately.
50
Note that other
volumes are available
on request.
28
72
18
50
30
ID 15.6
A-011504
ID 25.6
A-001056
A-001209
ID 46.4
A-012632
cell holder for A-011506
70
45
55
25.6
40
15,6
80
50
40
A-012672
A-001051
A-012652
Small & big volume cell vials
Volume
OD
ID
Height
Quantity Purpose
Catalog n°
Small volume sample vial
cell vials
5 mL
20 mL
100 mL
5 mL
20 mL
100 mL
18 mm
28 mm
50 mm
40 mm
55 mm
70 mm
15.6 mm
25.6 mm
46.4 mm
15.6 mm
25.6 mm
46.4 mm
30 mm
50 mm
72 mm
40 mm
50 mm
80 mm
90 mm
120 mm
90 mm
120 mm
62 mm
90 mm
62 mm
90 mm
80 mm
175 mm
85 mm
200 mm
10
10
1
1
1
1
1
1
1
1
1
1
A-011504
A-001056
A-012632
A-012672
A-001051
A-012652
A-001209
EL-A-001
EL-C-001
EL-A-002
EL-C-002
EL-C-019
water jacketed-glass vial
Big volume
cell vials
cell holder for 20 mL vial
sample vial
80 mL
1,000 mL
water jacketed-glass vial 80 mL
1,000 mL
cell holder for king size vial (1 L)
VC-4
SVC-2, SVC-3
RRDE-3A, bulk electrolysis
VC-4
SVC-2, SVC-3
RRDE-3A, bulk electrolysis
SVC-2, SVC-3
EL-ELECTRO-1
EL-CORR-1
EL-ELECTRO-2
EL-CORR-2
EL-CORR-1
cell
Analytical
Corrosion
Big volume cell vials,
100 to 2,000 mL
90
cell
62
90
Glassware
62
85
Electrodes
80
Rotating
EL-A-002
EL-A-001
electrodes
120
90
120
Quartz
crystal analyzer
Spectro-
electrochemistry
90
200
cell
Fuel
accessories
Battery
175
accessories
Connection
EL-C-001
EL-C-002
EL-C-019,
cell holder for EL-C-001
Dimensions in mm
ELECTROCHEMISTRY accessories
14/15
Glassware
Purge tubes
Bridge tubes
for corrosion cells
The tolerance of
each dimension
is approximately
±0.5 mm.
EL-C-008
EL-C-017
for corrosion cells
EL-F-004B
EL-F-004
EL-C-006
100
120
220
140
10
250
60
10
200
60
EL-C-016
10
10
10
A-012176
Small size
bridge tubes
A-012177
65
6
65
9
10
cell
Analytical
EL-A-006
R-AL100
100
R-AL110
cell
with ceramic junction
for analytical cells
EL-A-008
Corrosion
for analytical cells
EL-A-017
Bridge tubes
Purge tubes
R-AL120
Glassware
Bridge tubes
Electrodes
70
138
165
electrodes
165
Rotating
200
Spectro-
electrochemistry
250
10
10
crystal analyzer
EL-A-016
Quartz
10
Vycor type compatibility
Catalog n°
2
22
2
22
1
1
1
1
1
1
1
1
1
1
1
1
1
092-VYC3(1)
A-012176
A-012306
A-012177
A-012307
EL-C-008
EL-C-017
EL-F-004
EL-F-004B
EL-A-017
EL-A-008
EL-A-016
EL-A-006
EL-C-016
EL-C-006
R-AL100
R-AL110
R-AL210
Bridge tube
for corrosion cells
Bridge tube
for analytical cells
Purge tube
for analytical cells
Purge tube
for corrosion cells
Bridge tube
with ceramic junction
Ø 8 mm
Ø 6 mm
single
double
single
double
short
standard
with reverse sleeve
(non aqueous)
standard
SVC-2, SVC-3
SVC-2, SVC-3
SVC-2
SVC-2
EL-CORR
EL-CORR
EL-FLAT
EL-FLAT
EL-ELECTRO
EL-ELECTRO
EL-ELECTRO
EL-ELECTRO
EL-CORR
EL-CORR
8 mm 138 mm 1
Options
(1) Set of 10 porous 2.8 mm glass frit (CoralPor™) with PTFE heat shrink (200 mm)
(2) Set of 10 porous 4 mm glass frit (CoralPor™) with PTFE heat shrink (200 mm)
ELECTROCHEMISTRY accessories
092-VYC4(2)
accessories
Quantity Purpose
68 mm
68 mm
68 mm
68 mm
250 mm
250 mm
120 mm
140 mm
165 mm
155 mm
165 mm
200 mm
200 mm
220 mm
70 mm
250 mm
138 mm
10
cell
Height
6 mm
6 mm
9 mm
9 mm
10 mm
10 mm
10 mm
10 mm
10 mm
10 mm
10 mm
10 mm
10 mm
10 mm
12 mm
8 mm
8 mm
Fuel
OD
Ø 6 mm
Ø 6 mm
Ø 9 mm
Ø 9 mm
Ø 6 mm
Ø 8 mm
accessories
Ref. electrode
Small size bridge tube
Connection
Glassware
Battery
10
R-AL120
092-VYC3
092-VYC4
Dimensions in mm
16/17
Electrodes
Working electrodes
To address every
application, a wide
range of working
electrodes (WE)
is offered with
diameters ranging
from 7 µm
up to 6 mm and
built with different
materials.
Small type
Standard type
15
15
Long type
Micro type
Gauze type
15
23
70
55
10
55
25
110
3
6
4
35
6
Working electrode maintenance
To refresh the surface
of the electrode we
recommend polishing the
electrode after
each measurement.
Working electrodes maintenance
Catalog n°
PK-3 electrode polishing kit
A-011975
Content
0.05 µm polishing alumina (20 mL)
1 µm polishing diamond (10 mL)
Glass plate (1 piece)
Alumina polishing pad (10 pieces)
Diamond polishing pad (10 pieces)
A-001050
A-002054
A-002249
-
Spare parts
Alumina polishing pad (20 pieces)
Diamond polishing pad (20 pieces)
Emery paper UF800 (20 pieces)
Coarse polishing pad (20 pieces)
6 µm polishing diamond (10 mL)
A-001040
A-001041
A-012611
A-001042
A-002053
Dimensions in mm
Analytical
pH =0
pH = 7
cell
Platinum
1 M HCIO4
0.1 m kci
standard PFCE carbon electrode
Platinum
small PFCE carbon electrode
platinum gauze electrode
long platinum electrode
standard platinum electrode
small platinum electrode
micro platinum electrode
Gold
gold gauze electrode
long gold electrode
standard gold electrode
small gold electrode
micro gold electrode
Silver
standard silver electrode
Copper
small silver electrode
standard palladium electrode
small palladium electrode
standard nickel electrode
micro nickel electrode
standard copper electrode
Iron
micro copper electrode
standard iron electrode
Palladium
Nickel
Carbon
paste
standard carbon paste electrode hole depth 4 mm
small carbon paste electrode hole depth 4 mm
CPO carbon paste oil base 1 g
ELECTROCHEMISTRY accessories
Electrodes
Rotating
basal plane
edge plane
electrodes
standard pyrolytic graphite electrode
electrochemistry
micro carbon fiber electrode
Spectro-
small glassy carbon electrode
crystal analyzer
A-012744
A-002417
A-002012
A-012297
A-002411
A-012298
A-002412
A-002002
A-002007
A-002252
A-002253
A-002408
A-002409
A-011854
A-002250
A-012745
A-002420
A-002422
A-002013
A-002313
A-002009
A-002003
A-002015
A-002005
A-002251
A-012746
A-002418
A-002421
A-002014
A-002314
A-002010
A-002004
A-002006
A-002416
A-002419
A-002011
A-002315
A-002019
A-002319
A-002016
A-002273
A-002017
A-012584
A-002271
A-002018
A-012585
A-002210
A-002223
A-001010
Quartz
Catalog n°
3 mm
5 mm
3 mm
1.6 mm
1 mm
1.6 mm
1 mm
33 µm
7 µm
3 mm
3 mm
3 mm
1 mm
1 mm
25 x 35 mm
3 mm
5 mm
3 mm
1.6 mm
1.6 mm
100 µm
25 µm
15 µm
10 µm
25 x 35 mm
3 mm
5 mm
3 mm
1.6 mm
1.6 mm
100 µm
25 µm
10 µm
5 mm
3 mm
1.6 mm
1.6 mm
1.6 mm
1.6 mm
1.5 mm
100 µm
1.6 mm
3 mm
25 µm
1.5 mm
3 mm
3 mm
1.6 mm
accessories
Electrode size ±4%
6 mm
10 mm
6 mm
6 mm
6 mm
3 mm
3 mm
4 mm
4 mm
6 mm
6 mm
6 mm
6 mm
3 mm
80 mesh
6 mm
10 mm
6 mm
6 mm
3 mm
4 mm
4 mm
4 mm
4 mm
100 mesh
6 mm
10 mm
6 mm
6 mm
3 mm
4 mm
4 mm
4 mm
10 mm
6 mm
6 mm
3 mm
6 mm
3 mm
6 mm
4 mm
6 mm
6 mm
4 mm
6 mm
6 mm
6 mm
3 mm
Battery
OD
PEEK
PEEK
PEEK
PEEK
PEEK
PEEK
PEEK
glass
glass
PEEK
PEEK
PEEK
PEEK
PEEK
PEEK
PEEK
PEEK
PEEK
PEEK
PEEK
glass
glass
glass
glass
PEEK
PEEK
PEEK
PEEK
PEEK
PEEK
glass
glass
glass
PEEK
PEEK
PEEK
PEEK
PEEK
PEEK
PEEK
glass
PEEK
PEEK
glass
PEEK
PEEK
PEEK
PEEK
long glassy carbon electrode
standard glassy carbon electrode
cell
Isolation
Carbon
Fuel
Working electrodes
Glassware
3
accessories
-3
-2
-1
0
1
2
Electroactivity window of the working electrodes in different media
cell
V vs SCE
Connection
Carbon
Corrosion
pH = 14
TBAP/ACN
TBAP/DMF
18/19
Electrodes
Small size reference electrodes
for aqueous media (Ag/AgCl, Hg)
Reference electrodes
are divided into two
groups according to
the media in which
the electrode is
immersed (aqueous
or organic media).
RE-1B
RE-1S
RE-1C
RE-2B
RE-2C
50
RE-3V
RE-6A
40.5
45
40
80
11
2.8
45
50
2.8
6
Ag/AgCl ink
Small size reference electrode for aqueous media (Ag/AgCl, Hg)
Junction
Electrolyte
Purpose
Catalog n°
RE-1B silver, silver chloride reference electrode(1)
vycor glass
3 M NaCl
A-012167
RE-1S silver, silver chloride reference electrode
RE-1C silver, silver chloride reference electrode
vycor glass
ceramic
3 M NaCl
saturated KCl
RE-3V silver, silver chloride reference electrode
screw type, poly acetal resin
RE-3VP Ag/AgCl screw type electrode,
PEEK resin
Ag/AgCl ink, 2 mL
vycor glass
3 M NaCl
vycor glass
3 M NaCl
SVC-2, SVC-3, VC-4, bulk
electrolysis, RRDE-3A, flat cell
SECM
SVC-2, SVC-3, VC-4, bulk
electrolysis, RRDE-3A, flat cell
for flow cell spectroelectrochemcial
cell SEC-3F
for flow cell spectro
electrochemcial cell SEC-3F
for micro CV cell, IDA measurment
SVC-2, SVC-3, VC-4, bulk
electrolysis, RRDE-3A, flat cell
A-002056
(1)
RE-2B calomel reference electrode
RE-2C Hg2SO4 reference electrode,
free from chloride
RE-6A Hg/HgO reference electrode
main body in polyacetal resin
RHE Reversible Hydrogen Electrode kit
Maintenance
of Vycor-based
reference
electrode
- surface resistance: 0.2 Ω/sq/25.4 µm
- viscosity: 50,000 ±10,000 CP @21.1 °C
- flash point: 82 °C
ceramic
saturated KCl
A-012168
A-002058
A-012169
A-012170
A-011464
A-002057
ceramic
saturated K2SO4
ceramic
1M NaOH
for alkaline media
A-012974
vycor glass
HCl or H2SO4
for acidic media (pH < 2)
A-013373
Spare parts
(1) Set of 10 porous 2.8 mm glass frit (CoralPor™) with PTFE heat shrink (200 mm)
092-VYC3
Options
RE-PV preservative vial for reference electrode, 10 mL
Bridge tube Ø 9.0 mm (2 pieces)
Bridge tube Ø 9.0 mm (22 pieces)
Double junction chamber kit for RHE
A- 012108
A-012177
A-012307
A-013375
Store your reference electrode
immersed in the electrolyte
When it is not in use, the recommended way to
maintain the reference electrode capability and
lifetime is to keep it in a sealed preservative vial
with solution. This storage solution should be
identical to the filling solution of the reference
electrode.
Prevent contamination
To prevent contamination of the reference
electrode, a sample holder can be used.
Replace the vycor when needed
Yellowish discoloration indicates contamination.
This is caused by the adsorption of organic
compounds into the pores.
cell
Analytical
Corrosion
Small size reference electrodes
RE-7S
10
10
20
RE-7V
RE-7VP
5.5
5.5
Glassware
RE-7
cell
for non aqueous media (Ag/Ag+)
20
35
30
35
30
23
11
11
Electrodes
44
Electrolyte
solution
Electrolyte
solution
Electrolyte
solution
Rotating
Electrolyte
solution
electrodes
68
Catalog n°
CV
SECM
flow cell
flow cell
A-012171
A-012172
A-012173
A-012174
Spare parts
Electrolyte solution (10 mL)
PTFE cap with Ag wire (for RE-7)
PTFE cap with Ag wire (for RE-7S)
Sample holder 6 mm diameter (for RE-7) (2 pieces)
(1) Set of 10 porous 2.8 mm glass frit (CoralPor) with PTFE heat shrink (200 mm)
A-012549
A-012057
A-012058
A-012176
092-VYC3
Options
RE-PV preservative vial for reference electrode, 10 mL
Bridge tube Ø 9.0 mm (2 pieces)
Bridge tube Ø 9.0 mm (22 pieces)
A- 012108
A-012177
A-012307
* Acetonitrile
** Tetra Butyl Ammonium Perchlorate
accessories
Hg/HgO/ NaOH (0.1 M)
Hg/Hg2SO4 / K2SO4 (sat)
Fc/Fc+ TBAP (0.1M) ACN
Ag/Ag+ TBAP (0.1M) ACN
Hg/Hg2Cl2 KCl (sat)
Hg/Hg2Cl2 NaCl (sat)
Ag/AgCl/ KCl (3.5 M)
Ag/AgCl/ KCl (sat)
Ag/AgCl/ NaCl( sat)
NHE Normal Hydrogen Electrode
cell
0.930 V
0.650 V 0.624 V 0.542 V 0.241 V
0.236 V
0.205 V
0.197 V
0.194 V
0.000 V Fuel
65
accessories
A-012108
Battery
To avoid electrolyte leakage or concentration due to evaporation
during storage or transport, the electrolyte is separated from
the body. This gives the possibility to fill it regularly.
A-012177
Spectro-
Purpose
Ag/Ag+/ACN*/TBAP**
Ag/Ag+/ACN*/TBAP**
Ag/Ag+/ACN*/TBAP**
Ag/Ag+/ACN*/TBAP**
crystal analyzer
Electrolyte
vycor glass
vycor glass
vycor glass
vycor glass
Quartz
Junction
Connection
RE-7 non aqueous reference electrode (Ag/Ag+)(1)
RE-7S non aqueous reference electrode (Ag/Ag+)(1)
RE-7V non aqueous reference electrode (Ag/Ag+) screw type, poly acetal resin
RE-7VP non aqueous reference electrode (Ag/Ag+) screw type, PEEK resin
electrochemistry
Small size reference electrode for non aqueous media (Ag/Ag+)
E/V vs NHE at 25 °C
9
Dimensions in mm
ELECTROCHEMISTRY accessories
20/21
Electrodes
King size reference electrodes
R-REF621
R-XR110
R-XR200
R-XR300
R-XR400
R-XR820
m
eas
120
Connection type Junction
Length
OD
Catalog n°
banana cable
banana cable
screw cap(1)
banana cable
screw cap(1)
screw cap(1)
ceramic
ceramic
ceramic
ceramic
ceramic
ceramic
103 mm
103 mm
103 mm
103 mm
103 mm
103 mm
7.5 mm
12 mm
8 mm
7.5 mm
8 mm
8 mm
R-REF201
R-REF251
R-REF421
R-REF601
R-REF621
R-REF921
screw cap(1)
screw cap(1)
screw cap(1)
screw cap(1)
screw cap(1)
screw cap(1)
screw cap(1)
ceramic
ceramic
ceramic
ceramic
ceramic
ceramic
ceramic
120 mm
120 mm
120 mm
120 mm
120 mm
120 mm
160 mm
8 mm
8 mm
8 mm
8 mm
8 mm
8 mm
8 mm
R-XR110
R-XR150
R-XR200
R-XR300
R-XR400
R-XR440
R-XR820
banana plug of 2 mm
banana plug of 2 mm
banana plug of 4 mm
ceramic
ceramic
ceramic
1m
100 mm
1m
70 mm
138 mm
250 mm
138 mm
Options
(1) Cable connection for screw cap electrode,
recommended to connect these references electrodes
to the Bio-Logic instruments
Salt bridge
-Im(Z)/Ohm
3,000
Salt bridge with reverse sleeve, non aqueous
Conical rings for 8 mm OD 12 mm electrodes (4 pieces)
0
0
2,000
Re(Z)/Ohm
4,000
160
Red rod reference electrode
Calomel reference electrode non aqueous (LiCl)
for general purpose
Calomel reference electrode in KCl sat for CV, straight
Calomel reference electrode in KCl sat for CV, curved
Hg/HgSO4 reference electrode in sat K2SO4 for CV
Ag/AgCl reference electrode Sat KCl for CV
Hg/HgO reference electrode in 0.1 M KOH for CV
Hg/HgO reference electrode in 1 M KOH with fiber rod
Ag/AgCl reference electrode for EIS
1,000
u re m
King size reference electrodes
Hg/HgSO4 reference electrode in sat. K2SO4, chloride free
2,000
en
t
EIS
12 mm
8 mm
8 mm
8 mm
R-CRI9439
R-A94L111
R-CL111
R-AL100
R-AL120
R-AL110
R-AL210
R-X31M012
cell
Analytical
A-002233
A-002234
A-002250
R-XM110
R-XM120
R-XM140
R-XM150
cell
A-002222
Metallic electrodes
Corrosion
Counter electrodes
Glassware
23
10
25
50
Electrodes
35
120
A-012198
A-002254
Wire Ø
Surf. area
Purpose
Catalog n°
57 mm
0.5 mm
~ 0.7 cm2
A-002222
0.5 mm
0.5 mm
0.5 mm
0.5 mm
1.5 mm
0.08 mm
0.08 mm
0.07 mm
0.12 mm
~ 0.7 cm2
~ 3.6 cm2
~ 3.6 cm2
~ 3.6 cm2
~ 2.35 cm2
~ 1 cm2
~ 1 cm2
~ 1 cm2
~ 5.1 cm2
SVC-2, VC-4, plate material
evaluating cell
SVC-3
RRDE-3A, bulk electrolysis, SVC-3
RRDE-3A, bulk electrolysis, SVC-3
RRDE-3A, bulk electrolysis, SVC-3
flow cell
Wire dimension
Catalog n°
8 mm
8 mm
8 mm
12 mm
8 mm
Ø 1 mm
plate 5 x 5 mm
plate 8 x 8 mm
disk of 10 mm
rod Ø of 3 mm
R-XM110
R-XM120
R-XM140
R-XM150
R-M291C
Glassy carbon(1)
Options
(1) Cable connection for screw cap electrode,
recommended to connect these references electrodes
to the Bio-Logic instruments
Quartz
R-CRI9439
R-A94L111
R-CL111
R-X31M012
accessories
Conical rings for 8 mm OD 12 mm electrodes (4 pieces)
1 m, banana plug of 2 mm
100 mm, banana plug of 2 mm
1 m, banana plug of 4 mm
accessories
OD
80 mm
120 mm
120 mm
120 mm
103 mm
Battery
Length
Platinum(1)
cell
Metallic electrodes
Fuel
flat cell
A-002233
A-002234
A-012638
A-012639
A-012198
A-002250
A-702439
A-002251
A-002254
Connection
50 mm
230 mm
Gold
230 mm
Nickel
230 mm
Stainless steel
50 mm
Platinum gauze electrode, PEEK
80 mesh
25 x 35 mm
Platinum gauze electrode, platinum wire of 51 mm 25 x 35 mm
Gold gauze electrode, PEEK
100 mesh
25 x 35 mm
55 mesh
40 x 50 mm
Spectro-
Length
Platinum
crystal analyzer
Counter electrodes
electrochemistry
electrodes
Rotating
100
Dimensions in mm
ELECTROCHEMISTRY accessories
22/23
Rotating electrodes
Rotating Ring Disk Electrode
(RRDE)
RRDE-3A is a system that can be used to perform hydrodynamic
(RDE or RRDE) measurement. Its design (short stainless steel shaft)
allows the users to control accurately the electrode rotation and
the modulation.
RRDE-3A is electronically controlled by a closed loop circuit driving
a DC servo-motor. Electrodes are small and rapidly interchangeable.
The unit also provides an adjustable valve system for inert gas
purging inside the cell vial. Additionally, the access to glass cell
is easy for rinsing, cleaning, and replacing the electrodes.
It is easy to remove and replace the cell vial.
RRDE-3A is able to be operated as a stand-alone unit or directly
controlled by Bio-Logic electrochemical workstation.
Features
- Remote- and manual-controlled rotation
- Small sample volume (up to 10 - 15 mL), gas line connector
is available, remote and manual controlled purge lines
- Open architecture for easy access to cell
Specifications
Rotational range
Setting resolution
Accuracy
Rotation control type
Bandwidth
100 - 8,000 rpm
1 rpm
< 0.1%
PLL (phase-locked loop)
60 Hz at 3,500 rpm
base and 1,000 rpm
peak-to-peak modulation
Inlet gas pressure
5 PSI
Temperature
10-50 °C
Power
100-240 VAC, 50/60 Hz
Dimensions (W x D x H) 185 x (base: 230, body: 120) x 400 mm
Weight
6 kg
Rotating Ring Disk Electrode
Catalog n°
RRDE-3A apparatus
A-012180
Working electrodes (page 25), reference electrodes (page 20)
and counter electrodes (page 23) have to be purchased separately.
Content
RRDE-3A glass cell vial 100 mL
Spin coating adapter
Nipple for purge valve
Tygon tubing, OD 6.4 mm x ID 3.2 mm (1.3 m)
PTFE cap for RRDE-3A
Instruction manual
Power cable
Options
Water-jacketed glass cell
(100 mL, OD 70 mm, ID 46.4 mm, H 80 mm)
DB9 cable to control RRDE-3A
Bipotentiostat cable for two standard channels
Bearing assembly
A-012632
A-012064
A-012065
A-010058
A-012631
A-012652
092-22/11
092-22/12
A-012625
cell
Analytical
cell
Corrosion
A-011162
A-011163
A-011164
A-011170
A-011171
Glassware
A-011172
A-011169
Option
PK-3 polishing kit
Rotating
electrodes
electrochemistry
crystal analyzer
Quartz
accessories
A-013336
A-013337
A-013338
A-013339
A-013362
A-013338
A-013339
A-013361
A-013364
A-013366
A-013339
A-013361
A-013365
A-013367
A-013339
A-013361
Tool kit
Disk electrode polishing and exchanging tool kit
A-011172
A-011162
A-011163
A-011164
A-012617
A-012618
A-011169
A-011170
A-011171
A-011966
A-011967
A-011968
A-011969
A-011970
A-011971
A-011972
A-011973
Battery
Catalog n°
RRDE
RDE
Catalog n°
4.0 mm
4.0 mm
4.0 mm
4.0 mm
4.0 mm
4.0 mm
3.0 mm
3.0 mm
3.0 mm
3.0 mm
3.0 mm
3.0 mm
3.0 mm
3.0 mm
3.0 mm
3.0 mm
3.0 mm
5.0 mm
5.0 mm
5.0 mm
5.0 mm
5.0 mm
5.0 mm
-
A-011975
Disk Replaceable Electrode tips
platinum ring/GC disk replaceable electrode kit
content platinum ring assembly
glassy carbon disk
PTFE spacer (3 pieces)
glassy carbon disk replaceable electrode kit
content glassy carbon disk
PTFE spacer (3 pieces)
disk assembly
gold disk replaceable electrode kit
content gold disk
PTFE spacer (3 pieces)
disk assembly
platinum disk replaceable electrode kit
content platinum disk
PTFE spacer (3 pieces)
disk assembly
Disk Ø
7.0 mm
7.0 mm
7.0 mm
7.0 mm
7.0 mm
7.0 mm
-
12 mm
12 mm
12 mm
12 mm
12 mm
12 mm
12 mm
12 mm
12 mm
12 mm
12 mm
12 mm
12 mm
12 mm
12 mm
12 mm
12 mm
RRDE platinum ring/GC disk replaceable electrode kit
cell
Disk electrode Ø 3 mm
RDE
Ø 12 mm
Ring OD
25 mm
25 mm
25 mm
25 mm
25 mm
25 mm
25 mm
25 mm
25 mm
25 mm
25 mm
25 mm
25 mm
25 mm
25 mm
25 mm
25 mm
Fuel
RDE
Tips length Tips OD Ring ID
A-013340
accessories
Disk electrode Ø 4 mm
Ring electrode Ø 7 mm
RRDE
Ø 12 mm
platinum ring/platinum disk
platinum ring/glassy carbon disk
gold ring/glassy carbon disk
platinum ring/gold disk
gold ring/platinum disk
glassy carbon ring/glassy carbon disk
glassy carbon disk
platinum disk
gold disk
aluminum disk
silver disk
copper disk
nickel disk
tantalum disk
titanium disk
tungsten disk
carbon paste disk, hole depth 4 mm
Connection
RRDE
Spectro-
Standard tips
Electrodes
Working electrode
Disk electrode polishing and exchanging tool kit
ELECTROCHEMISTRY accessories
24/25
Rotating electrodes
Rotating Disk Electrode
(RDE)
Rotating Disk Electrode
Catalog n°
Rotating Disk Electrode system including control unit and
electrode rotator
R-RDE/EDI
Content
CTV101, controlling unit for EDI101
EDI101 RDE without tip (10-5,000 tr/min)
R-R21V035
R-A35T040
The CTV101 speed control unit controls the EDI101 rotation
speed. It offers accuracy better than ±0.1% for precise and
fully reproducible experimental conditions. The measured
rotation speed is clearly displayed on a four-digit LCD.
The speed control unit can be directly driven from a Bio-Logic
potentiostat/galvanostat. You can program the variation of
the rotation speed from one method to another method
and achieve a “Levich” type experiment all in one go.
Options
BEC/EDI electrochemical cell with glassware and electrodes
glassy carbon
Ø 3 mm
EDI tip
glassy carbon
Ø 5 mm
platinum
Ø 2 mm
platinum
Ø 5 mm
gold
Ø 2 mm
gold
Ø 5 mm
copper
Ø 5 mm
graphite
Ø 4 mm
silver
Ø 5 mm
nickel
Ø 5 mm
without any material
stainless steel
Ø 5 mm
sample holder
Ø 11 mm
platinum, L 40 mm
Ø 5 mm
gold, L 40 mm
Ø 4 mm
Adapter EDI (banana 4 mm female, banana 2 mm male)
R-XR51V001
R-A35T090
R-A35T095
R-A35T100
R-A35T105
R-A35T110
R-A35T120
R-A35T130
R-A35T140
R-A35T150
R-A35T160
R-A35T402
R-A35T420
R-A35T450
R-A35T452
R-A35T456
R-X41V001
This RDE can be used with the EL-ELECTRO-1,
EL-ELECTRO-2 or EL-ELECTRO-3 kit.
Specifications
Rotational range
Accuracy
Eccentricity
Setting resolution
Material of EDI101
Gas inlet for brush contact purging
Temperature
Power
Consommation
Dimensions
Weight
100 - 5,000 rpm
< 0.1%
< ±0.1 mm
1 rpm
KeI-F
Ø 2 mm
5 - 40 °C
230 Vac, 47.5 - 63 Hz
12 VA
CTV101: 80 x 240 x 230 mm (W x D x H),
EDI101: 255 mm (length)
CTV101: 1.5 kg
EDI101: 0.3 kg
I/µA
The EDI101 is a versatile and rugged rotating disk electrode
ideal for use with any Bio-Logic potentiostat/galvanostat. It is
available with a wide choice of quick-fit exchangeable tips in
standard or custom materials: platinum, glassy carbon, gold...
Thanks to its conic shaft holder, the EDI101 can be used with
a wide range of cells.
700
600
500
400
300
200
100
0
0
0,2
0,4
Ewe/V
0,6
0,8
1
Analytical
Rotating electrodes
For RRDE measurement, a bipotentiostat is
needed. A bipotentiostat controls the two working
electrodes i.e. one channel to control the disk
electrode and the other to control the ring. An
SP-300 equipped with two channels would be an
appropriate instrument for RRDE applications.
)
3/2
An example of the Levich analysis is performed
on a 5.5 mM Potassium Hexacyanoferrate (III),
in KCl (0.1 M) solution. The working electrode
is a glassy carbon disk electrode.
The sequence comprised of 13 rotational velocities
from 10 rpm to 2000 rpm, and 13 twin-cycle cyclic
voltammograms. The resulting CVs are overlaid
and presented in the image below. The Levich
analysis leads to the diffusion coefficient (D)
determination which is D = 6.36 x 10-6 cm²/s.
Current/mA
0.88
0.68
0.48
0.28
Rotating
C
electrodes
-1/6
Of these two options, the latter is preferred
because the leakage current is less. All of the
Bio-Logic multichannel potentiostats (except
cyclers) offer such electrode connection type.
electrochemistry
( 0.62 n FmA v
Spectro-
D=
Because of the presence of two working electrodes
in the same setup, a specific connection mode
(to avoid any ground loop trouble) is needed.
This can be achieved in two different ways:
- isolating the two channels (at least one
potentiostat in floating mode),
- grounding the counter electrode.
The “CE-to-ground” mode of the Bio-Logic
instruments provides this unique capability.
At the disk electrode, the electro-active species
are oxidized or reduced according to the applied
potential. This new species is detected by
reduction or oxidation at the ring, respectively.
In a typical experiment, a CV is performed on the
disk electrode and a constant voltage is applied
on the ring electrode. It is the CV-CA technique
that is available in EC-Lab® in the “bipotentiostat”
techniques folder.
crystal analyzer
Where:
- ω is the rotational velocity (radian per second),
- n electrons involved within the reaction
(dimensionless),
- F is the Faraday constant (F = 96,485 C/mol),
- A is the disk area (cm²),
- D is the diffusion coefficient (cm²/s),
- v is the kinematic viscosity (cm²/s),
- C is the electroactive species concentration
(mol/cm3).
Quartz
IL = ±0.62 n F A D2/3 ω1/2 v-1/6 C
cell
A 20th century electro-chemist, Dr. Levich
proposed the relationship between the voltammetry
limiting current (IL, A) of a rotating disk electrode
and the physical parameters as follows:
Glassware
RRDE
Electrodes
RDE
Corrosion
cell
applications
accessories
7.57
ω⁄s-1/2
14.1
accessories
Connection
cell
Fuel
1
Battery
0.08
ELECTROCHEMISTRY accessories
26/27
Spectroelectrochemistry
Spectrometer
Utilization modes
Spectroelectrochemistry (SEC) can be useful to
elucidate electrochemical reaction mechanisms.
The spectroelectrochemical kit is composed of
three parts (spectrometer, light source and
cuvette holder).
Transmittance
The spectrometer is equipped with a trigger
to synchronize electrochemical and
spectroscopic measurements.
Reflectance
Absorbance/ - Concentration of chemicals (solution)
transmittance - Polymer extrusion processes
- DNA quantification
- Freshness testing
- Film thickness/composition (quality control)
- Activation energy of photocatalytic species
- Textile quality control
Fluorescence
Fluorescence
- Marine organisms
- Biology (DNA, protein,
cell proliferation assay,
histamine-analysis, alga monitoring)
- Environmental fields (waste water analysis, ground water
trace studies, hydrocarbon detection, dissolved oxygen)
- Plant efficiency (plant physiology, plant breeding, horticulture,
agronomy, agrochemicals, pollution studies, forestry, ecology)
- Tissue diagnosis
Scattering
- Oil concentrations of oil/water system
- Raman spectroscopy
- Physical transition phenomena (e.g, melting point,
glasstransition crystallize temperature)
Irradiance
Emission
Spectrometer
combo kit type
Content
Spectrometer
Light source
Cuvette holder
30 sec
60 sec
90 sec
120 sec
150 sec
180 sec
210 sec
240 sec
270 sec
Absorbance
0,2
0
-0,2
300
400
Wavelenght
500
- Astronomy (e.g, spectra of Hale-Bopp,
plasma monitoring)
- In situmetal monitoring
- Luminescence (PL,EL), LED & laser wavelength
SEC2000-UV/VIS
Catalog n°
SEC2000-VIS/NIR
Catalog n°
SEC2000-UV/VIS
A-012838
SEC2000-VIS/NIR
A-012973
SEC2000-UV/VIS
SEC2000-DH UV
SEC2000-CUV
A-012856
A-012193
A-012195
SEC2000-VIS/NIR
SEC2000-TH visible
SEC2000-CUV with
diffusion plate
A-012971
A-012194
A-012244
Option
Connecting cable to synchronize the spectrometer and the Bio-Logic potentiostat
092-22/11
cell
Analytical
X-ray
Ultraviolet ray
Infrared
Ultraviolet ray (UV)
100 (UV-C)
200 nm
UV-B
280 nm
Millimeter
Meter
Microwaves
Radio waves
Visible light
Infrared (IR)
UV-A
315 nm
Kilometer
Near IR
400 nm
700 nm
1,400 nm
IR
cell
Gamma ray
Micrometer
Corrosion
Nanometer
Far IR
3,000 nm
Glassware
Picometer
10,000 nm
Electromagnetic spectrum
2,048 pixels CCD array
500 - 1,000 nm
blazed at 750 nm
1.8 ±0.2 nm: slit 50 µm x 1,000 µm (standard) (1)
< 1% at a Abs
< 2 mAbs
14 bit
SMA905
USB 2.0
WindowsTM XP
98 x 118 x 35 mm
A-012971
Rotating
SEC2000-VIS/NIR combo kit
electrodes
SEC2000-UV/VIS combo kit
2,048 pixels CCD array
220 - 800 nm
blazed at 400 nm
1.8 ±0.2 nm: slit 50 µm x 1,000 µm (standard) (1)
< 1% at a Abs
< 2 mAbs
14 bit
SMA905
USB 2.0
WindowsTM XP
98 x 118 x 35 mm
A-012856
electrochemistry
Detector
Wave length range
Grating
Resolution
Accuracy
Dark noise
A/D resolution
Optical entrance
Interface
Operating system
Dimensions (W x D x H)
Catalog n°
Electrodes
Spectrometer
Spectro-
(1). Slit could be selected from: 10, 25, 100, 200 μm.
Spare parts
Bulb
200 - 1,100 nm
200 - 400 nm
< 5 x 10-8 W/nmsr
1 x 10-3 AU
< 0.25%/h
> 1,000 h
> 2,000 h
360 - 2,000 nm
-
SMA905 included
98 x 118 x 35 mm
A-012193
SMA905 not included
98 x 118 x 35 mm
A-012194
A-012221 (UV bulb)
A-012222 (TV bulb)
Quartz
SEC2000-TH Light source
(tungsten halogen)
1,500 h
accessories
Battery
Spectral range (Halogen + D2)
D2 lamp spectral range
power consumption (240 nm)
stability
drift
bulb life(2)
Halogen bulb life
lamp
Connector
Dimensions (W x D x H)
Catalog n° light source
SEC2000-DH Light source
(deuterium & tungsten halogen)
crystal analyzer
Light source
cell
Fuel
(2). Value for less than 50% power consumption of 240 nm.
ELECTROCHEMISTRY accessories
SEC2000-UV/VIS combo kit
SEC2000-VIS/NIR combo kit
A-012195
A-012244
accessories
Catalog n°
Connection
Cuvette holder
28/29
Spectroelectrochemistry
Static experiment
45
40
39
100
13
6
A-012904
A-012907
Platinum
Quartz glass spectroelectrochemical cell kit
0.5 mm
Content
platinum counter electrode
thin layer quartz glass cell
PTFE cap
purging tube (ETFE, 100 mm)
gauze working electrode
80 mesh,
height 5 mm
1 mm
Content
platinum counter electrode
thin layer quartz glass cell
PTFE cap
purging tube (ETFE, 100 mm)
gauze working electrode
80 mesh,
height 6 mm
Options
RE-1B Ag/AgCl reference electrode
RE-7 non aqueous reference electrode
Purging tube (ETFE), 1 m
UA
0.5
0.1
0
.1
0
0
0
0
70
60
0
4
0
(nm)
65
ngth
55
50
40
0
30
8
45
35
0
0
-0
6
Catalog n°
A-012906
Gold
A-011501
A-012814
A-012609
A-012815
A-011501
A-012606
A-012609
A-012815
A-011501
A-012607
A-012904
A-012906
A-012907
A-011501
A-011498
100 mesh,
height 5 mm
100 mesh,
height 6 mm
10
12
14
16
Purging tube
Catalog n°
A-012813
5.5 mm
0.5 mm
5 mm
A-012905
A-012906
A-012907
A-011501
A-012017
A-012167
A-012171
A-010537
0.4
0.3
0.2
Wave
le
A-011498
6.5 mm
1 mm
6 mm
cell
Analytical
Glassware
cell
Corrosion
Options
Reference Ø 10 x 55 mm
electrode
screw type
A-012169
A-012170
A-012173
A-012174
A-012655
A-012656
A-012657
A-012658
A-011465
A-010887
A-011233
A-011827
A-012661
A-012664
A-012665
A-012666
A-012667
A-011522
A-012234
electrodes
Rotating
Outlet
Inlet
Gold grid electrode A-012656
Solution volumes
Gasket of
100 µm
250 µm
500 µm
Volume
4.6 µl
11.5 µl
230 µl
accessories
Connection
cell
Fuel
RE-3V aqueous
RE-3VP aqueous (PEEK)
RE-7V non aqueous
RE-7VP non aqueous (PEEK)
Working 8 x 27 x 1 mm
platinum (1 piece)
grid
gold (1 piece)
electrode
carbon grid electrode (1 piece)
for flow
ITO electrode (4 pieces)
cell
8 x 27 x 0.5 mm ITO electrode (12 pieces)
10 x 20 x 0.5 mm ITO electrode (10 pieces)
10 x 10 x 0.5 mm ITO electrode (30 pieces)
Ø 4 inch x 0.5 mm ITO electrode (1 piece)
Gasket
silicone
S500, 500 µm thick (4 pieces)
PTFE
T500, 500 µm thick (4 pieces)
T250, 250 µm thick (4 pieces)
T100, 100 µm thick (4 pieces)
Fibre and lens
400 m optical fibre SR, 250 mm
400 µm optical fibre SR, 2 m
UV/VIS collimating lens, 200-2,000 nm
A-012661
A-012198
-
electrochemistry
SEC-2F S500 silicone gasket
Stainless tube OD 1.59 mm (length of 50 mm)
Needle adaptor
Dynaseal PEEK fingertight
Silicon tube (300 mm)
PTFE tube (1 m)
1
1
1
1
2
1
1
2
1
1
Spectro-
base
cover
block A
block B
Working electrode
Silicone gasket 500 µm
Counter electrode
Collimating Lens
Reference electrode
crystal analyzer
A-012660
Quartz
Content
SEC-2F flow cell
Catalog n°
accessories
Quantity
SEC-2F spectroelectrochemical flow cell
Battery
Flow experiment
Electrodes
Flow experiment
ELECTROCHEMISTRY accessories
30/31
Spectroelectrochemistry
Thin layer
spectroelectrochemical
cell
UF-Full
The UFS set is conceived to perform
thin-layer spectroelectrochemistry.
Spacer
Thin layer spectroelectrochemical cell kit
Catalog n°
Full kit
UF-Full
Pseudo-reference
electrode
Content
1 PTFE windows aligner + 1 spacer (platinum or gold working electrode/platinum auxiliary electrode/
Ag pseudo-reference electrode)
Stainless steel body cell
XY holder (with magnets) to universally fit the cell in a spectrophotometer
Plug
PTFE mask
Working electrode
Auxiliary electrode
Full kit +
PTFE adapter for optical fibres + optical fibre
Options
PTFE adapter for optical fibres with UV/VIS/NIR collimating lenses (200-2500 nm),
adjustable focus, SMA-905 connection
Base stand for optical fibres measurements
PTFE cuvette holder to be used with UF-OFA and UF-BS
1 spacer (platinum working electrode/platinum auxiliary electrode/Ag pseudo-reference electrode)
1 spacer (gold working electrode/platinum auxiliary electrode/Ag pseudo-reference electrode)
Optical fibre: SMA-SMA connector length 1 m
UF-SEC
UF-XY
UF-P
UF-M
UF-OFA
UF-BS
UF-C
UF-SPP
UF-SPA
092-101
Analytical
Spectroelectrochemistry
cell
applications
Ferrocene in CH2Cl2/NBu4PF4 (0.2 M)
Scan rate: 5 mV/s
cell
Glassware
Electrodes
Due to the high Infra-Red absorbance of more
common solvents and electrolytes, a very carefully
measured background should be obtained before
each Infra-Red spectroelectrochemical experiment.
400
electrodes
Rotating
For the same reason, it is also important to avoid
changing the tightness of the cell screws during
the experiment itself to avoid changes of the
optical path.
Starting potential : 150 mV
Step of 50 mV
electrochemistry
A cyclic voltammetry should be registered in
your SEC cell to better localize the redox process
of interest: in fact, the UF spacer has an silver
pseudo-reference electrode, which is sensitive to
the solution medium (but is expected to remain
constant in time in each given experimental
condition). Potential drifts can be observed in
the presence of irreversible redox reactions, which
may alter the solution/analyte composition.
A milli-molar concentration appears to be the
most optimized concentration, but in some cases,
the concentration can be adapted.
Spectro-
Small potential sweep rates (2-10 mV/s) are
necessary both to ensure homogeneity of the
reactant/product concentrations in the cell and
to control the resistive effects.
To maintain the ohmic drop as low as possible,
the current should also be kept low which means
low scan rates and low sample concentrations
may be preferred. However, in some cases,
due to the narrowness of the optical path, the use
of a relatively high concentration of the sample
may be required to study the changes of bands
with a low molar extinction coefficient.
300
ε/cm-1.M-1
In such finite diffusion conditions, a thin solution
layer (≤ 0.2 mm) adjacent to the electrode is
confined by the cell walls, so that the cell thickness
is smaller than the diffusion layer and the mass
transfer can be ignored. The most significant virtue
of thin-layer cells is the absence of the effect of
the diffusion process and the rapidity with which
the electro-active species can be exhaustively
electrolyzed. The dropping to near zero of the
current flow following the peak in the current
potential plot is a characteristic behavior of
thin-layer cells, indicating exhaustive electrolysis
of the cell reactant and minimal diffusion effects
in thin-layer electrochemical cells(1) (2).
Corrosion
Finite diffusion conditions
200
Quartz
crystal analyzer
100
80
0
400
0
800
λ/nm
1,200
(1): M. Krejčik, M. Danĕk and F. Hartl, J. Electroanal. Chem.,
1991, 317, 179.
(2): P. Leoni, F. Marchetti, C. Bonaccorsi, F. Fabrizi de Biani,
L. Marchetti, P. Zanello, Chem. Eur. J.,2008, 14, 847
accessories
-40
Battery
I/mA
40
-80
0
0.2
0.4
0.6
accessories
Connection
cell
Fuel
Ewe/V
ELECTROCHEMISTRY accessories
32/33
Quartz crystal analyzer
092-QCA-FC
EQCM
The instrument monitors both the resonant
frequency and the resonant resistance which
are also reflected on the two analog outputs.
It is possible to connect the Quartz Crystal
Analyzer (QCA922) to a Bio-Logic potentiostat
using a DB9-8BNC cable (catalog n°: 092-22/1).
SE-CL3
EQCM
Catalog n°
Quartz crystal microbalance 9 MHz kit
SE-QCA922B
Content
EQCM 9 MHz (or 5 MHz) main unit
Adapter cable
Male BNC/BNC cable (2 pieces, length 1 m)
SE-QCA922-00
SE-QCA922-10
COR28100
Options
Holder is needed to get a full
QCM or EQCM set-up
static and flow QCA cell
dip cell
well cell (PTFE)
well cell (PEEK)
transparent well cell
flow cell (90 µL) (PTFE)
flow cell (90 µL) transparent (PTFE)
flow cell (90 µL) (PEEK)
Connector from QCA to potentiostat
Low flow peristaltic pump
EQCM specifications
Frequency range
Resonant resistance range
∆F output
Resistance output
Gate time
Display
Interface
Dimensions (W x D x H)
Weight
Temperature
Power consumption
0.8
0.6
<I>/mA
0.4
0.2
0
-0.2
0
0.5
Ewe/V
1
1 MHz-10 MHz,
resolution 0.1 Hz
10-16 Ω,
resolution 0.1 Ω
full scale: ±10 V (12 bit)
±200 Hz / ±2 kHz / ±20 kHz / ±200 kHz
full scale: 0-10 V (11 bit)
1 / 2 / 4 / 8 / 16 kΩ
variable (0.1, 1.0, 10.0 s)
40 digits x 2 rows
IEEE-488, RS-232C
260 x 230 x 88 mm
3.3 kg
0 - 40 °C
100-120 V AC, 230-240 V AC, 50-60 Hz, (15 W)
092-QCA-FC
SE-CL3
SE-CL4
SE-CL4PK
SE-CL5
SE-CL6
SE-CL7
SE-CL6PK
092-22/1
EL-AV-008
mirror
finish
resonator
and
lead wire
separated
lead wire
Others
Resonators lead wire no sputter (50 pieces)
Resonators 9 MHz, no sputter
no lead wire (50 pieces)
mirror finish no lead wire (50 pieces)
cell
cell
Corrosion
Glassware
separated
lead wire
Platinum
electrode
Electrodes
resonator
and
lead wire
Stainless
steel
electrode
Rotating
standard
finish
Gold
electrode
SE-LEAD/2
SE-9Q/2
SE-9Q-M/2
crystal analyzer
polish finish
electrodes
SE-5AU
SE-9AU-E/1
SE-9AU-E/3
SE-9AU-P/1
SE-9AU-P/3
SE-9SI
SE-9AL
SE-9AU
SE-9C
SE-9CU
SE-9MO
SE-9NI
SE-9PT
SE-9SS
SE-9SU
SE-9SOS
SE-9AU-S
SE-9PT-S
SE-9SOS-S
SE-9SU-M
SE-9AL-M
SE-9AU-M
SE-9AU-M2
SE-9C-M
SE-9CU-M
SE-9IT-M
SE-9SOS-M
SE-9NI-M
SE-9PT-M
SE-9SI-M
SE-9SS-M
SE-9TI-M
SE-9AU-MS
SE-9IT-MS
SE-9PT-MS
SE-9SOS-MS
etching finish
gold electrode (25 pieces)
gold electrode (30 pieces)
gold electrode (100 pieces)
gold electrode (30 pieces)
gold electrode (100 pieces)
silicon electrode (25 pieces)
aluminum electrode (25 pieces)
gold electrode (25 pieces)
graphite electrode (25 pieces)
cupper electrode (25 pieces)
molybdenum electrode (25 pieces)
nickel electrode (25 pieces)
platinum electrode (25 pieces)
stainless steel (SUS304) electrode (25 pieces)
stainless steel (SUS316L) electrode (25 pieces)
SiO2 for solution measurement (25 pieces)
gold electrode (25 pieces)
platinum electrode (25 pieces)
SiO2 for solution measurement (25 pieces)
stainless steel (SUS316L) electrode (25 pieces)
aluminum electrode (25 pieces)
gold electrode (25 pieces)
gold electrode (500 pieces)
graphite electrode (25 pieces)
copper electrode (25 pieces)
ITO electrode (25 pieces)
SiO2 for solution measurement (25 pieces)
nickel electrode (25 pieces)
platinum electrode (25 pieces)
silicon electrode (25 pieces)
stainless steel (SUS304) electrode (25 pieces)
titanium electrode (25 pieces)
gold electrode (25 pieces)
ITO electrode (25 pieces)
platinum electrode (25 pieces)
SiO2 for solution measurement (25 pieces)
electrochemistry
Catalog n°
5 MHz
9 MHz
Spectro-
Quartz resonator (calibration at 5 MHz at factory with no charge when purchased)
Analytical
Quartz resonators
accessories
Electrode materials deposition
sputtered
vacuum deposition
sputtered
vacuum deposition
Battery
Roughness
0.6 µm
0.6 µm
0.06 µm
0.06 µm
accessories
Connection
cell
Fuel
Standard finish
Etching finish
Mirror finish
Polish finish
Quartz
Surface finishing
ELECTROCHEMISTRY accessories
34/35
Quartz crystal analyzer
Biosensor QCM
The specification (27 MHz) of the Quartz Crystal
Microbalance (QCM934) allows users to measure
a small mass change. QCM934 is especially
suitable in the bio-sensing field.
- Excellent sensitivity and resolution.
- Specially designed oscillation circuit
for added stability.
- Simultaneous measurement of resonant
frequency, resonant resistance and
temperature.
- Expandable up to 4 channels.
- Works with flows cell, well cell, dip cell.
- Computer control and data collection
via USB interface.
Flow mode
Catalog n°
Flow cell kit
SE-QCM934-F
Content
Main unit
WinQCM software
Oscillator & temperature control module
Cable for oscillator & temperature
control module
Measurement chamber
Flow cell (90 µL)
Options
Additional channel
Low flow peristaltic pump
Resonators of 9 MHz are compatible
with QCM934 and the cell (see page 35).
Specifications
Frequency range
25 MHz-27 MHz, resolution 0.01 Hz
Resonant resistance range 2 Ω, resolution 0.1 Ω
Max channel
4
Gate time
variable (0.1, 1.0, 10.0 s)
Display
20 digits x 2 rows
Interface
USB 2.0
Dimensions (W x D x H)
320 x 280 x 133 mm
Weight
5.5 kg
Temperature
10 - 40 °C
Power consumption
100-120 V AC, 230-240 V AC,
50-60 Hz, (60 W)
SE-QCM934-000
SE-WQCM
SE-QCM934-200
SE-QCM934-200A
SE-QCM934-500
SE-QCM934-510
SE-QCM934-1CHF
EL-AV-008
Oscillator & Temperature
Control Module
Osc.Status
Temp.Status
Power
QCM934
Quartz Crystal Microbalance
“Flow cell-based system of QCM934”, “perista pump” and
“notebook computer”
Batch mode
Catalog n°
Batch cell kit
SE-QCM934-B
Content
Main unit
WinQCM software
Oscillator & temperature control module
Cable for oscillator & temperature
control module
Cable for OSC module connection
SE-QCM934-000
SE-WQCM
SE-QCM934-200
SE-QCM934-200A
Options
Additional channel
SE-QCM934-300
SE-QCM934-1CHB
Dip cell
QA - CL3
Oscillator & Temperature
Control Module
Osc.Status
Temp.Status
Power
QCM934
Quartz Crystal Microbalance
Transparent well cell
QA -CL5
“Batch cell-based system of QCM934”, “transparent well/dip cell”
and “notebook computer”
Analytical
Quartz crystal analyzer
cell
applications
N
R
R
N
N
+ (2n+2)H+ + (2n+2+np)e-
R
The quartz electrode was immersed in an acetonitrile
solution (Bu4NPF6 0.2 mol.L) containing a solution
of 1 methylpyrrol monomer (0.01 mol.L).
Polypyrrol film growth on the quartz
working electrode
Corrosion
cell
Glassware
Electrodes
∆ƒ/kHz
electrodes
-0.2
300
-1
200
The mass calculation
is done automatically
in the process data
tool of EC-Lab®. More
details can be found in
the application note(3).
-1.4
150
100
-1.8
50
-2.2
0
-2.6
-50
electrochemistry
-0.6
250
90
95
100
Time/s
105
Spectro-
Fig. 2: graphic zoom
on one cycle showing
the resonant frequency
and the current density
versus elapsed time(3).
Rotating
The interesting point is to follow the frequency evolution
versus potential on one cycle. The figure below shows the
time evolution on one cycle.
110
-40
120
-60
100
-80
80
-100
60
-120
40
1,000
2,000
Time/s
(1): G
. Sauerbrey, Phys. Verh., 1957, 8, 113-114.
(2): G
. Sauerbrey, Z. Phys., 1959, 155, 206-222.
(3): A
pplication note #13. Section “Apps & literature of EC-Lab division”.
accessories
Connection
Fig. 1 presents the polypyrrol film growth on the
quartz electrode during the successive cycles of cyclic
voltammetry. The reversibility of the charge transfer in
such a polymer film is often dependent on the deposition
mode (quasi-reversible in this example). The growth is
very regular but tends to slow down in the last cycles.
That can be due to an interfacial depletion of the
solution in methyl pyrrol species in the layer close to
the electrode surface and to a saturation of the
working electrode surface area.
0.5
1
Ewe/V vs. Ag/AgCl / KCl (sat’d)
crystal analyzer
N
-12
Quartz
(n+2)
-200
0
np+
R
-10
accessories
The polypyrrol film was coated on an Au quartz
(used as the working electrode) using cyclic
voltammetry (20 cycles).
-8
-100
Battery
Electropolymerization of pyrrol
-6
0
cell
ƒ0: resonant frequency (Hz)
∆ƒ: frequency change (Hz)
∆m:mass change (g)
A:piezoelectrically active crystal area
(area between electrodes, cm²)
ρq: density of quartz (ρq = 2.648 g/cm³)
µq:shear modulus of quartz for AT-cut crystal
(µq = 2.947x1011 g/(cm.s²))
-4
100
Fuel
A ρqµq
∆m
-2
200
∆ƒ/kHz
2ƒ02
0
300
∆ƒ/kHz
∆ƒ =
Fig. 1: overlaid
frequency and current
vs. Ewe of the polymer
film growth. Scanning
at 100 mV/s between
0 and 1.018 V.
∆m/µg
The Sauerbrey equation is defined as:
Fig. 1 shows the resonant frequency decrease and the
resonant resistance increase while the polymer film is
growing. Moreover the variation is dependent on the
potential sweep resulting in a pseudo oscillation of
frequency and resistance related to the successive cycles.
This plot can also be made versus potential (see fig. 1).
<I>/mA
A mass increase results in a frequency decrease.
Sauerbrey was the first who provided a description
and experimental verification of the mass/frequency
relationship between foreign layers firmly attached
to the quartz crystal resonator(1)(2).
QCM measurements
during the film growth
<I>/mA
The Quartz crystal microbalance is a mass-sensitive
detector based on frequency changes of an oscillating
quartz crystal. The oscillation frequency of the crystal
is proportional to the mass of the crystal, as well as
solution properties near the surface (including viscosity,
density, temperature, and compression waves).
ELECTROCHEMISTRY accessories
36/37
Battery accessories
Test cells
3-electrode
test cell
These cells allow users to
characterize the electrode
(positive and negative electrode).
With the ECC-Ref test cell
(E-ECC-REF) a reference electrode
(Lithium wire) can be used to follow
the behavior of the negative and
positive electrode simultaneously.
ECC-AIR
Test cells
Catalog n°
For lithium Ion battery and
2-electrode test cell
other aprotic electrochemical 3-electrode test cell
system
2/3-electrode test cell
2/3-electrode test cell for gas analysis
5-electrode test cell (0.10 mm)
E-ECC-STD
E-ECC-REF
E-ECCCOM
E-ECCDEM
E-ECCMREF
Options
ECC-Std-kit, to upgrade E-ECC-STD to E-ECC-REF
ECC-Ref-kit, to upgrade E-ECC-REF to E-ECC-STD
For both aqueous and aprotic 2/3-electrode test cell
electrochemical systems with
Options
ref electrode
adjustment tool
For measuring
ECC-press-DL
gas evolution and
ECC-press-Aqu
for drawing gas samples
ECC-press-Air
(pressure test cell)
ECC-press
This can be done with a VSP,
VMP3 or MPG2 that offer a
5-lead type connection.
Other cells for specifics
utilization are also available.
For gas diffusion electrodes
For optical characterization
Option
cable to connect Bio-Logic instrument (DB9 connector)
to ECC-press
ECC-AIR electrochemical test cell (in aprotic media)
ECC-AIR electrochemical test cell
E-ECCSTD-K
E-ECCREF-K
E-ECCAQU
E-ECCAQU-1
E-ECCP-DL
E-ECCP-AQ
E-ECCP-A
E-ECCP
E-C-Press
E-ECCAIR
E-ECCAIR-N
Options
ECC-AIR-kit
ECC-Opto Std face to face
ECC SBS side by side, complete
E-ECCAIR-K
E-ECCOPT-S
E-ECC-SBS
Options
ECC-Opto Aqu-kit
lid (ECC-Opto) XRD, 6 mm
lid (ECC-Opto) XRD
lid (ECC-Opto) 10 mm
E-ECCOPT-4
E-ECCOPT-3
E-ECCOPT-2
E-ECCOPT-1
Tools
Electrode alignment and assembly tool
Catalog n°
Catalog n°
ECC CellLoad
E-ECCLOAD
E-ECCLI16
E-ECCLI17
E-ECCLI18
E-ECCLI19
E-ECCLI20
Options
REF - cleaning tool set
REF- load
Removing tool
E-ECC-104
E-ECC-103
E-ECC-102
Load the metal lithium
Catalog n°
REF-load for test cells (allow us to load lithium
metal inot REF bore of the E-ECC-REF)
E-ECCLOADR
Punching tool for lithium foil
Catalog n°
6 mm
7 mm
8 mm
9 mm
10 mm
E-ECCLI6
E-ECCLI7
E-ECCLI8
E-ECCLI9
E-ECCLI10
Catalog n°
11 mm
12 mm
13 mm
14 mm
15 mm
E-ECCLI11
E-ECCLI12
E-ECCLI13
E-ECCLI14
E-ECCLI15
16 mm
17 mm
18 mm
19 mm
20 mm
cell
Analytical
cell
Corrosion
Glassware
The dilatometer is a research grade instrument
dedicated to the measurement of chargeinduced strain (expansion and shrinkage) of
electrodes down to the sub-micrometer range.
The dilatometers have been developed for
the investigation of Li-ion battery and other
insertion-type electrodes. It may be used in
organic as well as aqueous electrolyte solutions.
Dilatometer
Catalog n°
Electro chemical dilatometer ECD-nano-DL (complete)
Electro chemical dilatometer ECD-2-DL (complete)
E-ECD-N
E-ECD-2DL
Options
Cable to connect Bio-Logic instrument (DB9 connector) to ECD-nano-DL
Cable to connect Bio-Logic instrument (DB9 connector) to ECD-2-DL
E-C-N
E-C-2DL
Specifications
2.5
2.5
3.5
0
50
Time/h
100
150
Rotating
accessories
Battery
Quartz
2
3
electrochemistry
Ewe/V
2
3
Spectro-
1.5
capacitive
LVDT
250 µm
500 µm
< 0.1% of full range
< 0.15% of full range
≤5 nm
≤50 nm
≥10 Hz
≥10 Hz
≤20 nm/h
≤100 nm/h
1.0 N (fixed)
0.3 N or 1.0 N (variable)
aprotic organic electrolytes, optional aqueous electrolytes
≤3 mL (ca. 2 ml electrolyte required)
-20 to 70 °C
2-electrode, 3-electrode (reference), auxiliary
-10 to 10 V
230 x 100 x 110 mm
2.5 kg
crystal analyzer
1
3.5
Displacement/µm
0.5
4
ECD-2-DL
electrodes
ECD-nano-DL
Displacement sensor
Dilatation range
linearity
Resolution
Bandwidth
Drift (sample-free)
Load on test specimen
Chemical compatibility
Cell electrolyte volume
Temperature range
Electrode configurations
DC output voltage
Dimensions (H x W x D)
Weight
0
4.5
Electrodes
Dilatometers
Cutting pliers
Catalog n°
16.5 mm
17 mm
17.5 mm
18 mm
19 mm
19.8 mm
Option
Cross hair to reduce cutting scrap, stop rail, assy
ELECTROCHEMISTRY accessories
E-ECS16B
E-ECS17
E-ECS17B
E-ECS18
E-ECS19
E-ECS19B
Catalog n°
20 mm
21 mm
22 mm
23 mm
24 mm
E-ECS20
E-ECS21
E-ECS22
E-ECS23
E-ECS24
cell
E-ECS11
E-ECS12
E-ECS13
E-ECS14
E-ECS15
E-ECS16
Fuel
Catalog n°
11 mm
12 mm
13 mm
14 mm
15 mm
16 mm
Docking station for 5 test cells Catalog n°
ECC-Stand for 5 test cells (ECC series)
(complete)
E-ECCSTAND
accessories
E-ECS6
E-ECS7
E-ECS8
E-ECS9
E-ECS9B
E-ECS10
Connection
Catalog n°
6 mm
7 mm
8 mm
9 mm
9.5 mm
10 mm
E-ECS-R
38/39
Battery accessories
Battery
Holder
- 4-point measurement,
- 4 A maximum current,
- adaptable to a wide variety of battery sizes
(coin cells, 18 650 or 26 650 cells),
- ability to link together many battery holders.
Battery Holder
Catalog n°
BH-1, dimensions (W x D x H) 134 x 79 x 185 mm
092-22/10
Coin Cell
Holder
The coin cell holder is
directly plugged to the
potentiostat connectors.
No cable is required.
4 coin cells can be
investigated simultaneously.
Rack
To get a compact setup,
it is possible to put five
units in a rack with
a lateral tablet for a
computer.
It is possible to use this
rack for VMP3, booster
chassis, HCP and CLB
only if the sliding option
is not purchased.
Rack for MPG-2xx series up to 5 units
Catalog n°
Including ethernet switch, power plugs,
computer tablet
With sliding tablet including ethernet switch,
power plugs, computer tablet
092-85/1
092-85/2
Specifications
Maximum units
5 units
Dimensions rack
600 x 710 x 1850 mm
(W x D x H) shelf with the sliding tablet 495 x 450 x 257 mm
shelf without the sliding tablet 495 x 450 x 295 mm
Temperature range
10 - 40° C
Coin Cell Holder
Catalog n°
CCH, dimensions (W x D x H) 82 x 83 x 65 mm
092-22/14
cell
Analytical
cell
Corrosion
Glassware
Current Collector (CC5)
Electrodes
Up to five current boosters can be connected in
parallel, increasing the maximum current that can
be passed through the cell. In order to simplify the
connections, a current collector was designed.
094-201/1
electrodes
electrochemistry
Catalog n°
CC5 Current Collector (5 channels)
for VSP-300/VMP300
Spectro-
Current Collector for 5 boosters
Rotating
A maximum current of 60 A can flow through the
CC5 (Current Collector for 5 boosters). This simple
device collects the current coming from each
booster in parallel and delivers it through two
600 mm power cables terminated by two sturdy
crocodile copper clips, similar to automobile battery
clips. All the boosters need to be connected
to each other using the DB 15 connectors.
Quartz
crystal analyzer
Sense Adapter
Module (SAM-50)
092-26
accessories
Catalog n°
SAM-50
accessories
Connection
cell
Fuel
Sense Adapter Module
Battery
To be added to a multichannel system to perform
stack measurements up to 50 V for 5 channel
boards and a 10-element measurement.
ELECTROCHEMISTRY accessories
40/41
Fuel cell
Membrane Electrode
Assemblies (MEA)
These MEAs are based on a 50 µm-thick
perfluoronated membrane, and a platinum loading
of 0.5 mg/cm² (±0.05), obtained with the standard
catalyst concentration, 70% Pt/C.
- 3 layers MEA corresponds to a Catalyst Covered
Membrane (CCM): the proton exchanged
membrane is covered with an ink containing the
catalyst on the electroactive area. Platinum and
platinum-Ruthenium alloys are available for
hydrogen and reformate operations respectively.
- 5 layers MEA corresponds to a CCM with Gas
Diffusion Layers (GDL) completing the electrodes
on the electroactive area on both sides of the
membrane.
- 7 layers MEA corresponds to a 5-layer MEA with
a flat gasket (fiberglass reinforced silicon) around
both electrodes.
A subgasket, protecting the membrane and the
edges of the active layer can be added to 5 and
7-layer MEAs.
Membrane Electrode Assemblies (MEA)
Catalog n°
Single cell fixture
(without MEA's)
095-08/1
095-08/2
095-07
095-08
095-08/3
095-09/13
095-09/14
095-09/15
095-09/16
095-09/17
095-09/18
095-09/1
095-09/2
095-09/3
095-09/4
095-09/5
095-09/6
095-09/7
095-09/8
095-09/9
095-09/10
095-09/11
095-09/12
Membrane Electrode
Assemblies
5 cm²
16 cm²
25 cm²
50 cm²
100 cm²
5 cm²
16 cm²
25 cm²
50 cm²
100 cm²
225 cm²
3 layers
5 layers
7 layers
3 layers
5 layers
7 layers
3 layers
5 layers
7 layers
3 layers
5 layers
7 layers
3 layers
5 layers
7 layers
3 layers
5 layers
7 layers
MEA selection
Only the 7-layer MEAs is fully active.
The other 3-layer and 5-layer MEAs need
to be modified.
50
I/A
40
30
20
10
0
0.4
0.6
Ewe/V
0.8
cell
Analytical
cell
Corrosion
Glassware
Electrodes
electrodes
Catalog n°
095-20/2
095-20/3
095-20/4
095-20/5
095-20/7
095-20/9
095-20/10
095-20/6
095-20/8
accessories
Connection
cell
Fuel
Options
25 cm² air-breathing cell (no MEA)
Power supply by two photovoltaic cells
095-20/1
electrochemistry
PEM#1: 25 cm² air-breathing cells
(MEA S25-7L N50-Pt/C 70%),
no possibility to dismantle the cell
PEM#2: 25 cm² air-breathing cells
(MEA S25-7L N125-Pt/C 70%),
no possibility to dismantle the cell
PEM#3: 25 cm² air-breathing cells
(MEA S25-7L N212-Pt/C 40%),
no possibility to dismantle the cell
Electrolyzer kit (including gas line)
Variable resistance
Data acquisition
(including connection, data logger, software)
Power supply 220 V
110 V/220 V adapter for 110 V configuration
Spectro-
Content
PEM kit
095-20/A
095-20/B
crystal analyzer
110 V electrical grid
220 V electrical grid
Quartz
Educational kit
(fuel cell /electrolyzer)
accessories
A porous material is placed inside the kit for the
homogeneous diffusion of hydrogen over the whole
surface area of the membrane electrode assembly.
Educational kit
Battery
The educational fuel cell kit is very simple and easy
to use: just plug the hydrogen tank into the cell and
let the fuel cell use the oxygen in the surrounding
air to produce electricity.
- 1 plastic electrolyser cell (25 cm²) containing a
7-layer membrane electrode assembly. At the
anode side of the electrolyser cell there is a water
reservoir, the hydrogen gas produced comes out
of the cell via one of the gas exits on the top and
bottom side of the cell. A plastic screw is included
for closing the unused gas exit.
- 1 plastic air-breathing fuel cell (25 cm²).
The cell has one hydrogen gas input and one exit.
Rotating
Educational kit
ELECTROCHEMISTRY accessories
42/43
Connection accessories
Specific cables
By default, the potentiostat and
the booster are provided with
a cell cable of 1.5 m long.
The cable connected from the
booster to the potentiostat is
800 mm long for VMP3 based
instruments.
For some applications, the user
may need cables with different
length. That’s why, longer cable
are offered.
Moreover for applications
performed in glove box, hermetic
cell cables are also offered.
Set-up connection
Bad connection could
induce some effects on the
measurement (effect on the
stability of the potentiostat,
artifact...).
We recommend the user to
optimize the set-up by using
the accessories offered in
this section.
Hermetic cell cable for glove box
Catalog n°
SP-50, SP-150, BiStat, VSP, VMP3, MPG2
A Jaeger connector 12 pins ensures the hermetic junction
(hole diameter to make in the glove box wall: 27 mm):
- cable with 2 mm connectors in one side and 12 pins Jaeger
connector in the other side (length 1 m),
- cable with DB-25 connector in one side and 12 pins Jaeger
connector in the other side (length 1.5 m),
- one feedthrough seal
SP-200, SP-240, SP-300, VSP-300, VMP-300
A Jaeger connector 25 pins ensures the hermetic junction
(hole diameter to make in the glove box wall: 45 mm):
- cable with electrometer in one side and 25 pins connector
in the other side (length: 1 m)
- cable with DB-25 connector in one side and 25 pins connector
in the other side (length: 1.5 m)
- two feedthrough seals one installed in the glove box wall the
other dedicated to the channel board calibration outside the box
092-23/5
094-101/6
Connection cable from booster to potentiostat Available length Catalog n°
All boosters
3m
5m
092-33/5
092-33/6
Longer cable
Available length
Catalog n°
SP-50, SP-150, VSP, VMP3, MPG2
2.5 m
3m
5m
10 m
2.5 m
3m
5m
2.5 m
3m
5m
092-23/2
092-23/7
092-23/3
092-23/4
092-33/11
092-33/12
092-33/13
092-33/21
092-33/22
092-33/23
Booster 2 A, 4 A, 5 A
Booster 8 A, 10 A, 20 A
cell
Analytical
cell
Corrosion
Glassware
Nstat box (8 channels)
Bipot cable: dedicated to RRDE applications
Electrodes
Multi-electrode
investigation cables
Nb of channels
Length
Catalog n°
4
8
8
2
2
2
1.5 m
1.5 m
1.5 m
1.5 m
3m
4m
092-16
092-22/3
092-22/4
092-22/12
092-22/12A
092-22/12B
low current
standard
092-16/1
Spectro-
Option
External power supply for the Nstat box (this option is needed if more than one
Nstat box is connected to VMP3 or if the user uses VSP)
electrodes
Bipot cable
(for VSP, BiStat, VMP3)
Channel
standard
electrochemistry
Nstat box
(for VSP, VMP3)
Rotating
Multi-electrode investigation cables
Quartz
crystal analyzer
External device
connection
DB9-8 BNC connector for auxiliary I/O
PT100 temperature probe,
to be connected to the auxiliary I/O,
temperature range: -50 °C to 250 °C,
dimensions: 3 x 20 mm,
length of cable: 2.5 m
IS1 isolation module for auxiliary I/O
for SP300 based instruments
092-22/1
092-22/13
accessories
External device connection
Battery
DB9-8 BNC connector
Catalog n°
ELECTROCHEMISTRY accessories
PT100 temperature probe
accessories
IS1
Connection
cell
Fuel
094-081/5
44/45
Connection accessories
Test Box 2
Test Box 3
Test Boxes
DC2
Dummy cell for booster
Dummy cells
Test Boxes
Catalog n°
Test Box 2 several circuits with high precision
resistors. For calibration and validation
Test Box 3 3 circuits: linear, exponential, non-linear.
For teaching and demonstration
092-22/6
092-22/7
The dummy cell for booster is especially
dedicated to check periodically a booster.
It is provided whith each booster chassis.
The dummy cell for booster and DC2
can be bound together as well.
Dummy cell
DC2
Dummy cell
for booster
Catalog n°
1 R/C circuit.
For standard check
1 power resistor, 5 mOhm.
For standard check
Dummy cell for
booster specifications
Resistance/mΩ
5
Standard tolerance
Temperature coefficient
1%
±50 ppm/°C
Standard Faraday cage
Advanced Faraday cage
Faraday cages
To avoid any external perturbations, specially
for low current application, we recommend using
the Faraday cage.
Please note that to activate this protection, Faraday
cage has to be connected to the ground of the
instrument (green plug on the rear panel of the
instrument).
Faraday cages
Catalog n°
Standard Faraday cage,
for standard channel
400 x 200 x 600 mm
for low current channel
Advanced Faraday cage, 286 x 230 x 320 mm
N-FAR600
NS-FAR600
A-012033
Advanced Faraday
cage specifications
Temperature
Power supply
Fuse
Gas pressure
Interface
Weight
0 - 50 °C
100 VAC-240 VAC, 50/60 Hz
1A
< 34 kPa max.
IEEE-488, RS-232C
3.8 kg
094-111/3
092-32/1
cell
Analytical
Corrosion
cell
Connectors
Catalog n°
Red colour
092-1001/2
Blue colour
092-1001/26
Alligator clip 4 mm
(pack of 5)
092-1001/13
092-1001/14
092-1001/23
Socket 2 mm female
(pack of 10)
092-1001/5
092-1001/6
092-1001/7
Socket 4 mm female
(pack of 10)
092-1001/25
092-1001/4
092-1001/3
Banana plug 2 mm
(pack of 10)
092-1001/9
092-1001/10
092-1001/11
092-1001/12
092-1001/16
092-1001/15
092-1001/24
092-1001/19
092-1001/20
092-1001/21
092-1001/18
Banana adapter 2 mm
female socket to 4 mm male plug
(pack of 5)
Adapter for banana 2 mm
female socket to 4 mm male plug
(pack of 5)
Banana adapter 4 mm
female socket to 2 mm male plug
(pack of 5)
Yellow colour
Electrodes
092-1001/8
092-1001/17
Rotating
Banana plug 4 mm
(pack of 5)
White colour
092-1001/22
Glassware
Black colour
092-1001/1
Alligator clip with 2 mm connector (pack of 10)
electrodes
Connectors
electrochemistry
092-1001/27
For booster board
blue, white, red, black,
blue, white, red
blue, white, red
red, black
blue, white, red
blue, white
092-1001/30
092-1001/31
crystal analyzer
- 4 alligator clips of 2 mm:
- 3 sockets of 2 mm:
- 3 alligator clips of 2 mm:
- 2 alligator clips of 4 mm:
- 3 sockets of 2 mm:
- 2 sockets of 4 mm:
Quartz
Connection kit
For standard board
Spectro-
092-1001/28
094-082
094-091
accessories
Catalog n°
SP-200
SP-240/SP-300
accessories
Connection
cell
Fuel
Transport cases
Battery
Transport cases
ELECTROCHEMISTRY accessories
46/47