IN-FIRE
Transcription
IN-FIRE
IN-FIRE Series 603 - 683 - 743 604 - 684 - 744 USER'S MANUAL, MAINTENANCE MANUAL INSTALLATION INSTRUCTIONS 07DH683A 04/98 Dear Customer Congratulations on the purchase of your new Bodart & Gonay appliance! Your choice shows the interest you have for high quality products. You are now a full member of the large international family of Bodart & Gonay customers, who have enjoyed for many years the elegance, efficiency and reliability of our equipment. This is why we deem it important to provide you with this user's and maintenance manual: to allow you to use your equipment under the best possible conditions and in the most optimal manner, and furthermore to increase its operating life. We strongly advise you to read it carefully. And, of course, to store it in a place where you are sure to find it again without any problem. We also provide hereunder a space where you can note for yourself the date of purchase, reference and the name and address of your supplier, so that this information is always kept safely. Also keep carefully the invoice or proof of purchase (necessary for the guarantee) and we advise you to clip them together with this manual. We wish you every satisfaction with your Bodart & Gonay equipment. After sales service. * Type of equipment: ................................................................................................................ * Reference: .............................................................................................................................. * Date of purchase: ....../....../20...... * Dealer: - name: .................................................................................................................... street: ........................................................................................................................ city: ........................................................................................................................ phone: ..................................................................................................................... In order to put back the baffles in the position adapted to your chimney stack after a chimney sweeping, note here the ideal position (cf. page 21, adjustment of the baffles): - Upper baffle: open - ½ open - closed - Lower baffle: open - closed -2- TABLE OF CONTENTS USERS AND MAINTENANCE MANUAL A. IMPORTANT RECOMMENDATIONS 4 B OPERATION OF THE APPLIANCE 5 C. MAINTENANCE 10 D. OPERATION ANOMALIES 12 E. GUARANTEE 13 INSTALLATION INSTRUCTIONS A. SAFETY 15 B. RECESS 16 C. CHIMNEY 16 D. HOT AIR DUCT 18 E. ELECTRICAL INSTALLATION 18 F. ADJUSTMENT OF THE BAFFLES 21 G. DISMANTLING THE BAFFLES: 22 H. INSTALLATION OF THE APPLIANCE 23 -3- USERS AND MAINTENANCE MANUAL A. IMPORTANT RECOMMENDATIONS - Pull to open the door flap. - Carry out the installation and follow the safety rules (cf. installation instructions). - It is imperative to place the parker screw in the middle of the above cross bar of the frame, in order to attach the frame to the body of the appliance. - FIRST FIRE: * Set the fans to maximum speed to run them in (during about 12 hours). * The first fire bakes the paint which leads to an emission of smoke (ý VENTILATE THE ROOM) DO NOT TOUCH THE PAINT UNTIL THE APPLIANCE HAS COOLED, BECAUSE IT GETS SOFT AT THE FIRST FIRING. - IT IS MANDATORY AT EACH FIRE: * TO SHUT THE DOOR OF THE ASH BOX * TO CLOSE THE DOOR FLAP * OPERATE THE CONVECTIONS FANS (except when running at the minimum rate) -4- B. OPERATION OF THE APPLIANCE I. USE OF THE CONTROL AND SAFETY DEVICES 1) The door flap: NEVER KEEP IT OPEN DURING THE OPERATION OF THE APPLIANCE. ALWAYS CLOSE IT BEFORE OPENING THE DOOR. NEVER OPEN IT WHEN THE DOOR IS OPEN. 2) The thermostat: It adjusts the quantity of primary air for burning in function of its position. Its flap opens and closes according to the temperature of the convection chamber. Its control button is telescopic to make its operation easier. 3) The secondary air dosing device: It allows to increase (lever to the left) or to decrease (lever to the right) the secondary air flow which also removes the smoke from the glass window. 4) The door of the ash box: It provides access to the ash box and to the de-ashing arm. IT MUST ALWAYS BE TIGHTLY CLOSED WHEN THE FIRE IS ON (otherwise the combustion air is not controlled and the fire races. ý OVERHEATING OF THE APPLIANCE). -5- 5) De-ashing arm: To use it, pull it towards the front. It is used to adapt the grate to the type of fuel to be burnt (left position: open grate for coal; right position: closed grate for wood). Removing the ashes is made by moving it from the right to the left. 6) The ashpan: In the shape of a shovel to allow the collection of ashes at the back of the equipment. Monitor the filling of the ashpan and empty it before it overflows. 7) Closing the door and the "cold handle":With the DOOR FLAP CLOSED place the cold handle in the hole of the latch to open and close. 8) Closing lever: USE THIS LEVER TO CLOSE THE DOOR FLAP. 9) Microswitch: A switch which automatically stops the fan convection when the door is opened. 10) The convection air filters: They prevent dirt accumulation on the fans and the circulation of dust. They may be removed without tools for cleaning. The variator: It allows you to control the speed of the fans. 1. Adjustment of the speed. 2. 2A fuse (remove the button, unscrew the plate and pull for replacement) 3. Adjustment screw for the minimum speed - under the button (calibrated in the factory) -6- 2 OPENING AND CLOSING THE DOOR WHEN A FIRE IS ON, OPEN THE DOOR SLOWLY. A fast opening may lead to a temporary spillage of smoke. TO SHUT THE DOOR, lift the handle, press the door against the combustion chamber in order to crush the seal slightly, then lower the handle to its stop position. 3 OPERATING WITH DIFFERENT FUELS: 1) Wood The QUALITY of the wood is ESSENTIAL for an optimal operation of the appliance (efficiency, cleanliness of the window, ...). A quality wood is a dry wood having dried at least 2 years under a ventilated shelter. To use your appliance with WOOD, you must place the GRATE in the CLOSED POSITION. Closed position Model IF 600 Maximum load Recommended load for 1 hour at max. rate 5 kg 2.5 kg IF 680 7 kg 3 kg IF 740 9 kg 3.5 kg REMARK: The use of briquettes is similar to operation th wood. LIGHTING THE FIRE: -7- 1. OPEN fully the air flow: THERMOSTAT on 9. Place the grate in the open position (lever to the left). 2. Place crumpled paper (or fire lighters) and KINDLING FIREWOOD in the appliance on the grate. 3. LIGHT the FIRE. 4. Leave the door SLIGHTLY AJAR to avoid an accumulation of dirt on the window, its temperature is too low it could leads to condensation and a deposit of particles on the glaas if the door is closed to early . 5. As soon as the window is sufficiently HOT, CLOSE THE DOOR. 6. Wait until the kindling firewood burns briskly and LOAD the first logs, choosing the smaller ones to start with. 7. START the VENTILATION (variator "ON"). 8. When the fire is hot, CLOSE THE GRATE (lever to the right), adjust the thermostat to the position wanted. 9. ADJUST THE SPEED OF THE VENTILATION in function of the quantity of hot air that you need. LONG DURATION COMBUSTION: - Keep a bed of glowing embers of 3 to 5 cm on the bottom of the appliance. Choose logs of very high cross section. Position the thermostat in accordance with the draught of your chimney. A reduced rate is generally obtained from 0 to 3 enabling your fire to be kept in for longer periods overnight burning. REMARK: - - The use at a reduced rate for a long time may, because of condensation, lead to an accumulation of creosote in the chimney and thus to a risk of setting the chimney on fire. AVOID A OPERATING AT A REDUCED RATE WHEN THE ATMOSPHERIC CONDITIONS ARE UNFAVOURABLE (low pressure and high humidity) as this could cause problems . -8- 2) Coal Use anthracite or non bituminous coal, with a size of 20/30 (or 12/22 if the draught is sufficient). To use your appliance with COAL, place the GRATE in the OPEN POSITION. Open position REMARK: For people frequently using coal, a basket of heat resisting steel is available as an accessory. It allows a better combustion of the coal and a protection of the air distributor at very high combustion temperature. LIGHTING A COAL FIRE: Points 1 to 5 as for wood fuel. 6. START the VENTILATION. 7. Place two coal shovels full of coal, WITHOUT SPREADING IT on the top of the briskly burning fire. 8. As soon as the fire burns through, place a LOAD of about 2.5 to 4 kg (depending on the model). 9. When the fire has burnt through the mass (flames will appear), add a SECOND LOAD. 10. Let the fire increase before reducing GRADUALLY the air admission until the position corresponding to the heat requirement is reached. 11. ALSO ADJUST THE SPEED OF THE VENTILATION. -9- REMARK: do not use the equipment with coal in warm weather. The draught and the burn rate being reduced, the combustion risks to becoming incomplete. 3) Prohibited fuels The use of treated wood (painted, ... etc.) and any other salvaged material that can emit noxious gazes for the environment and aggressive towards the components of the appliance is NOT ALLOWED and eliminates the rights of guarantee. For the same reasons, PETROLEUM COKE must not be used. The use of LIQUID FUELS (petrol, ...) is FORBIDDEN (even to light the fire). 4 THE USE OF THE SECONDARY AIR DOSER The Bodart & Gonay appliances have been designed to provide the best possible combustion. The least polluting combustion for the environment is obtained by closing as much as possible the air doser (positioned to the right). However, depending on the draught and the fuel, this position may lead to a faster dirtying of the window. In this case open gradually the air doser towards the left until a satisfactory situation is obtained. 5 OPERATION OF THE THERMOCONTACT (OPTION) This thermocontact is a switch that automatically switches the ventilation on when the equipment is hot and stops it when it has cooled. At the time of LIGHTING, there is a DELAY of about 20 minutes before it switches on, this is NORMAL. C. MAINTENANCE CHIMNEY SWEEPING: Not only to comply with the LAW, but from the point of view of SAFETY, have the chimney swept at least once per year. S Dismantle the 2 baffles (cf. "Dismantling the baffles"). Close the door, thermostat, secondary air doser and the ash box door. S Place the grate in the closed position (wood). S After the dust has settled, it can be removed with a vacuum cleaner. Check the state of the components subjected to high combustion temperatures. Small deformations do not prevent them from pursuing their good service. - 10 - CARRY OUT THE FOLLOWING OPERATIONS: * AIR DISTRIBUTOR: clear, if necessary, the air intake holes. * GRATES: check that there are no objects limiting their movements. * FANS: DISCONNECT the power supply, DISMANTLE the filter supports (remove the 2 blocking screws), DISCONNECT the fans, then REMOVE them. CLEAN the vanes of the turbines using a brush (COMPRESSED AIR IS NOT ALLOWED). RE-ASSEMBLE all. * DUST FILTERS: clean them with a vacuum cleaner and if necessary with water. * THERMOSTAT: check its correct clearance. Your dealer can check the adjustment. * DOOR: check the sealing of the stainless steel seal. If necessary, your dealer may adjust or replace it. Check the correct operation of the lock and of the opening safety. * WINDOW: if, for cleaning, you use a chemical product, PROTECT the exposed painted surfaces. We recommend the use of the "BG Clean" product available at your dealer's. * ASH BOX DOOR: check the state of the seal and if necessary replace it to ensure correct sealing. Check the operation of the spring clip. * REFRACTORY BRICKS: a split brick may function quite correctly. However, a missing piece should lead to the replacement to maintain an efficient protection of the appliance. * PAINT: the soiled areas may be restored using aerosols of a special HIGH TEMPERATURE paint, available at your dealer's. * LUBRICATION: in frequent use, it is recommended to lubricate every year the following elements: S door and door flap: hinges and lock S thermostat: control axis. DO NOT USE NORMAL GREASE. In fact, subjected to high temperatures it would dry up and lead to a seizing. If necessary, clean thoroughly the surfaces, then apply a GREASE RESISTANT TO HIGH TEMPERATURES, available at your dealer's. - 11 - D. OPERATION ANOMALIES ANOMALIES CURES THE WINDOW GETS DIRTY TOO QUICKLY - Check the humidity of the fuel - Open the secondary air doser - Open the passage of the baffles ( cf. "Adjusting the baffles") VENTILATION Does not function - Check the operation of the two motors - Check the microswitch - Check (and replace) the fuse of the variator - Check the thermocontact (option) - Check (and repair) the power supply VENTILATION Operates but the flow is low - Clean or replace the filters - Clean the vanes of the turbines Excessive DRAUGHT - Tighten the passage of the baffles (cf. Installation) - Consult your dealer DRAUGHT Too low with a possible generation of the room smoke in - Check the chimney (cf. installation instructions) - Remove the possible obstruction - Have the chimney swept - Open the passage of the baffles (cf. "Adjustment of the baffles") Trouble linked to weather conditions - If this is permanent, consult your dealer THE FIRE IS NOT BRISK ENOUGH - Check the humidity of the fuel - Check the thermostat - Empty the ash box - Clear the holes of the distributor THE THERMOSTAT DOES NOT CLOSE ANY MORE: - A foreign body prevents the closing of the flap - Mechanical blocking - Remove the foreign body - Replace the thermostat THE THERMOSTAT REMAINS CLOSED: 1. When COLD, the flap only rises from mean positions 2. When COLD, the flap does not rise THE FIRE CANNOT BE CONTROLLED: - The DOOR of the ash box is open or unsealed - The DOOR of the appliance is not sealed - Calibrate the adjustment - Replace the thermostat - Check the correct closing of the ash box door - Check the seal, replace if necessary - Adjust again the door seal - Adjust again the position of the closing roller In case the chimney catches fire, immediately close the door, the ash box door, close the thermostat and the air doser. - 12 - E. GUARANTEE DURATION AND LIMITATION - 6 years guarantee on: the general structure - 2 years guarantee on: the inner removable parts - 1 year guarantee on: grates, thermostat, fans and speed variator - no guarantee on: window, seals, bricks and cast iron plates. RESERVATIONS Bodart & Gonay reserve the right to modify their equipments, catalogues, and manuals independently, at any time and without prior notice. The validity of the guarantee is cancelled in case the mandatory recommendations of this manual are not fulfilled. The intervention under the guarantee are only made through the dealer on presentation of the purchase invoice. Parts will be delivered only against the faulty parts. EXCLUSION Disasters, breakdown or faulty operation linked to: - inadequate relation between the nominal power of the equipment and the heat requirements of the premises; - a faulty installation or faulty connections; - a damage to the thermostat through overheating due to intensive use: * the ash box door is left open * the ventilation is left off - an insufficient or excessive draught; - incorrect use; - non compatible fuels, destructive and/or damp fuels (treated wood,...); - consumption exceeding the use limits; - a lack of maintenance; - the use of electrical or electronic components that are not approved by Bodart & Gonay; - any modification, transformation inside the appliance; - transport and installation. Transport and packaging cost. All costs not previously accepted by Bodart & Gonay. Costs due to the non-use of the equipment. TAKING EFFECT - 13 - The guarantee starts on the date written on the invoice. The invoice is the only document valid for the guarantee. -14- INSTALLATION INSTRUCTIONS Your dealer is the SPECIALIST that BODART & GONAY has chosen to represent them in your area. For your SAFETY and SATISFACTION we recommend that you entrust him with carrying out your installation. The appliance must be installed in compliance with the rules of building regulations and any local regulations. As there are no precise regulations in Belgium, the French installation regulations (D.T.U. 24.2.2) are applicable. However, if you want to assume the installation, to avoid any mistakes allow us to recommend that you: - refer to the terms of our guarantee; - take the advice of your dealer. As it is impossible to mention all the particularities of all cases that may occur, we limit ourselves to the important points: A. SAFETY: - COMBUSTIBLE MATERIALS must be avoided in the proximity of the appliance and of the connection to the chimney. Example: a decorative wooden beam above the appliance requires to be well insulated. - INSULATING MATERIALS: use preferably materials that withstand HIGH TEMPERATURES (DO NOT USE GLASS WOOL). Example: around a metal part linking to the chimney, a ceramic insulation is mandatory. - THE SEALING OF THE CHIMNEY and of the linking parts is absolutely required in order: * to prevent any combustion gas leak * not to interfere with the draught of the chimney - Any COMBUSTION consumes AIR. From the gap under the door to the direct outside air intake, every one must choose the solution best adapted to the installation to compensate the slight consumption of air. Never create a depression in the room where the appliance is installed. DO NOT SEAL ALL THE AIR INTAKES. -15- IF AN EXTRACTION FAN CANNOT BE AVOIDED IN THE SAME PREMISES, AN ADEQUATE AIR INTAKE MUST BE PROVIDED TO AVOID ANY DEPRESSION. B. RECESS - Clear the recess for connecting to the chimney, and possibly, for the hot air ducts. Remove any sinks and dampers. - Make up the lateral and rear walls with a clearance of 2 cm around the appliance in order to be able to insert it with its insulation. This will provide a better heat yield, in particular if the equipment is placed against an outside wall. - In the case of masonry, it is FORBIDDEN to place masonry on the top of the InFire. The appliance is not load bearing. C. CHIMNEY The chimney flue must be made according to the best rules of the trade, here are the most important ones: - minimum height 4 m - the cross section must be neither too small (not less than the output cross section of the equipment) or too large (risk of condensation and poor draught) - the flue must be thermally insulated - avoid sloping parts, never exceed a slope of 45 ° and avoid any sharp bends of direction (large curving radius) - THE OUTPUT OF THE CHIMNEY AND ITS PLACEMENT ARE VERY IMPORTANT: ask for advice from a chimney expert (any device which reduces the cross section at the output must be avoided) - if there are obstacles near the output of the chimney, they must be taken into account. - foresee later chimney sweepings - connect only one appliance per flue - in case of a double flue: * choose the best one; * seal the one that is not used. -16- - in case of a lateral connection to an existing flue, make one of the following assemblies: SOOT TRAP - TIGHTNESS AND CLEANLINESS are important. - Seal all the linking parts so that the bottom of the flue socket is placed 10 mm higher than the top of the appliance that will be introduced. . Tightness Infire height + 10 mm - On installation, if necessary install a draught regulator. The depression must be measured at the time of the first fire. The IDEAL DRAUGHT is between 10 and 20 Pa (1 to 2 mm water column). If it goes outside these limits, it is MANDATORY to act on the chimney. D. HOT AIR DUCT Two ducts may be connected above the equipment to heat contiguous rooms. To install these ducts, limit their length, avoid as much as possible any bends and changes of direction, the resulting decrease of speed reduces the efficiency of the hot air output at the end of the ducts. -17- According to the requirements and the risk of heat loss, insulation of these ducts is useful. Remark: an efficient hot air circuit requires an air return so as to avoid depression in the room where the appliance is. For each room concerned, a ventilating grid placed near the ground allows the cooled air to come out of the place in order to complete its circuit. E. ELECTRICAL INSTALLATION Connexion: - Remove the filter support on the side you chose, corresponding to the power supply (unscrew the 2 mounting screws, turn and remove the filter support). - Bring the flexible power cable in front of the opening foreseen in the equipment. Provide a sufficient length for the connection and to facilitate possible later interventions. If, for the connection, you have removed the protecting stops, place it on the connector of the second fan that is not used. Stop to be placed on free connector - Avoid using the same circuit as those of the audio and video equipment. - Do not install the variator near these household equipments. BEWARE! The use of a variator and/or internal fuse which is not approved by Bodart & Gonay risks the exclusion to the right of the guarantee on the whole of the electrical equipment. -18- Diagram of the electrical connection in the in-fires (without thermocontact) MICRO-SWITCH 1 2 3 4 1. Blue 2. Brown 3. Black 4.Yellow-green Electrical connection diagram for the infires (with thermocontact) 1. Blue 2. Black 3. Yellow-green 4. Brown Position of the fans: The fans are mounted on self-gripping pads. TAKE CARE TO AVOID ANY DIRECT CONTACT BETWEEN THE FAN AND THE STRUCTURE OF THE APPLIANCE TO AVOID THE TRANSMISSION OF VIBRATIONS. Dismantling of the microswitch - The microswitch is situated in the left fan case. - Disconnect the power supply. - With the door closed, and door flap open, dismantle the left filter frame. -19- - Unscrew the two screws. SCREWS F. ADJUSTMENT OF THE BAFFLES The baffle system is designed to adapt the appliance to the draught of the chimney. The baffles rest on square supports. Baffles from the most closed to the most opened position (pictures 1 to 3). -20- Picture 4: wrong position. The upper baffle has on each side 3 positioning notches, allowing to open or close the flow of smoke at the back, as well as a release notch for the assembly and dismantling of the baffles. 1. POSITIONING NOTCHES 2. RELEASE NOTCH The lower baffle may be turned around and thus open the passage for the smoke in the front (for instance if the equipment forces back to easily). It also includes two release notches. 1. POSITIONING NOTCH 2.RELEASE NOTCH The most closed position is the best for the efficiency of the appliance. However, if the equipment tends to smoke back, open the baffles gradually. -21- G. DISMANTLING THE BAFFLES: 1. Place the upper baffle in the release position 2. Raise slightly the lower baffle and move it to bring the release notch at the height of the square support. 3. Lift one side and try to lower the other side of the baffle by passing the square support through the notch. 4. Remove the baffle obliquely outside of the appliance. 5. Raise slightly the upper baffle and move it to bring the release notch at the height of the square support. 6. Lower one side of the baffle by passing the square support through the notch. 7. Remove the baffle obliquely outside of the appliance. To re-assemble them, proceed inversely with the same steps. H. INSTALLATION OF THE APPLIANCE 1. Dismantle the removable parts: - the door (open to more than 45° and raise); - the baffles (cf. Dismantling the baffles); - the kit of refractory bricks or cast iron and the grids. 2. Introduce and position the appliance in the recess. 3. Connect the hot air sockets, if necessary through the output of the chimney. -22- 4. Connect the flue pipe into flue socket. AND SEAL WITH FIRE CEMENT ADHESIVE. 5. Carry out the electrical connection through one of the sides, either left or right. 6. Assemble the covering frame using the angle piece, washers and nuts. DO NOT TIGHTEN TOO MUCH, THIS WOULD DISTORT THE FRAME ON THE FRONT FACE. 7. Placement of the frame. After carrying out the assemblage of the corners, screw the parker screw (picture 1) on the upper cross bar. Place the frame (pictures 2-3). You just have to slide it between the covering and the springs. For the 3-side frame, slide the lower piece (picture 4) -23- A parker screw B Spring C Covering D Frame 8. Re-assemble the movable parts. Place the baffles in the most closed position (cf. Adjustment of the baffles). 9. Check the operation of the control elements, the opening safety of the door and the two fans (LEAVE ON MAXIMUM SPEED FOR THE FIRST FIRE). 10. Remove the dust on the visible painted surfaces. 11. Make a first fire to bake the paint (ventilate the room and do not touch the appliance). CHECK THE DRAUGHT. 12. Adjust the position of the baffles if necessary (cf. Adjustment of the baffles). Note the ideal position of the baffles for your chimney in the space provided on the first page of this manual. This will allow you to position them again correctly after a chimney sweeping. -24- Positioning of the baffles for the "INFIRE the 603-683-743" The system of baffles is conceived to adapt the hearth to the pulling of the chimney. The baffles are posed on square supports. The drawings show positioning, from the position most closed towards most open. Caution: in the most open position, it is necessary to turn over the lower baffle. The most closed position Average position Most open position. Lower baffle turned around Prohibited Position F:\HOME\RD\ME\GRAPH PDF\INFIRE\positionnement_chicane_FR_ES OPCIONES Y RECAMBIOS IF 603 OPTIONS AND SPARE PARTS IF 603 RECAMBIOS / SPARE PARTS Ref 02 03 04 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 32 33 34 35 36 37 38 39 40 41 42 43 44 45 45 46 46 47 47 48 49 50 52 53 --------- Concepto Code 37117400 07VM0150 37660002 37660072 07RV1036 27660026 37660018 27660043 07Q04002 17660013 03SZA008 27660014 27660015 37115018 07BP0103 17660000 1774P006 27660000 07FTS670 07EVDDA3 27668023 07NB08 37660006 07EEVENC 17660018 17000002 07EEG006 17660011 07MB05 27660016 27660017 37660000 07PBE001 37116241 27660024 27660020 27660019 37660015 37660016 03J706A6 07FFIG3 07FFIF62 07CB328 07FF0303 07CB300 07FF0301 07CB313 07FF0302 07CB305 07CB327 07CB325 07CB326 07CB325 07CB7160 07GR03 37674008 37674017 BOQUILLA AIRE CALIENTE DIA 125 EMPALME INOX TUBO CHIM DIAM 150 KIT MARCO RECUBRIMIENTO 3C 603 KIT MARCO RECUBRIMIENTO 4C 604 CERAM 505X297X4 IF.603/604 CONTRA PUERTA 603 FACHADA MONTADA IF 603 (98) TAPA BASCULANTE IF 603 (98) EJE BISAGRA DIA 6 LG125 MANDO APERTURA PUERTECILLA IF 96 FIX RAPID C2631 ZF (AMARILLO) SEGUNDA TEJA 683 TEJA 603 ATIZADOR MANO FRIA PRISMA SOPORTE PESTILLO 683 PESTILLO PRISMA FIJACION PESTILLO 683 TERMOSTATO TELESCOPICO DIA70 VENTILADOR DDL 76-86 (62-68) MARCO FILTRO 683 FILTRO 157X121X10 ARNES 1996 VARIADOR PARA EMPOTRAR EJE BISAGRA PUERTECILLA IF96 (98) TUERCA SWITCH - CLIP CLAP MICROSWITCH CON PULSADOR AISLANTE SWITCH IF 96 TAPON CAUCHO ICLB 1800-3 DOSIFICADOR AIRE SEGUNDARIO SOPORTE DOSIFICATOR 603 PUERTA CENIZERO 603 CLIP PUERTA CENIZERO BRAZO LIMPIACENIZA (88) CENIZERO 603 DEFLECTOR AIRE 603 REPARTIDOR AIRE 603 PARALENOS IF 603 SOPORTE PARALENOS IF96 TORNILLO SWAGEFORM (TH) M6X12) PARRILLA HIERRO FUNDIDO INF.LG PARRILLA ACERO CRO.SUP LG 210 LADRILLO 165X120X30 PLACA FUNDICION 165X120X30 LADRILLO 240X120X30 VT20 PLACA FUNDICION 240X120X30 LADRILLO 240X60X30 BISELADO PLACA FUNDICION 240X60X30 LADRILLO 150X120X30 BISELADO LADRILLO 120X60X30 BISELADO LADRILLO 180X60X30 BISELADO LADRILLO 150X120X60 BISELADO LADRILLO 180X60X30 BISELADO KIT LADRILLOS FONDO IF 603/604 GRASA SILTEMP HT 4 GR KIT LADRILLOS IF 603-683-743 1996 KIT FUNDICION IF 743/744 OPCIONES / OPTIONS Ref 54 ----------- Code 37680048 17660074 27660029 37660003 37660004 37660005 Concepto KIT THERMOCONTACTO INFIRE RC93 KIT BARBACOA IF 96 KIT PARA LENO FUNDICION STOP AIRE IF 96 MARCO 15 MM 4C IF 604 MARCO 15 MM 3C IF 603 Description HOT AIR PIPE DIA 125 PIPE ADAPTOR DIAM 150 3 SIDED FRAME KIT IF603 96 4 SIDES FRAME IF604 96 CERAM. 505X297X4 IF603/604 ST. STEEL SEAL IF603 1996 ASSEMBLED FACADE IF 603 PAINTED TIPPING COVER JOINT PIN DIA 6 LGTH 125 COVER OPENING LEVER IF96 RAPID FASTEN C 2631 ZF (YELLOW TOP BAFFLE IF603 1996 LOW BAFFLE IF603 1996 POKER COLD HANDLE IF96+PRISMA LATCH SUPPORT IF 96 LATCH INFIRE 95 LATCH CATCH IF96 TELESCOPIC THERMOSTAT DIA 70 FANS DDL76-86 (62-68) FILTER FRAME INFIRE 96 BULPRENS 157X121X10 ELECTICAL CONNECTION IF96 VARIATOR TO BE INSERTED HINGE AXLE IF 96 (98) SWITCH NUT-CLIP CLAP IF 96 MICROSWITCH WITH BUTTON SWITCH INSULATOR IF 96 COVER NAIL SECONDARY AIR DOSING IF603 DOSING SUPPORT IF603 ASHPAN DOOR IF603 ASHPAN DOOR SPRING D950207 ASH REMOVING ARM (88) ASHPAN IF603 AIR DEFLECTOR IF603 1996 AIR DISTRIBUTER IF603 1996 LOG RETAINER IF 603 LOG RETAINER HOLDER SCREW SWAGEFORM (TH) M6X12 LOWER CAST IRON GRATE LG 240 UPPER STEEL GRATE LG 210 BRICK 165X120X30 CAST IRON BRICK 165X120X30 REFRACTORY BR.240X120X30 VT20 CAST IRON BRICK 240X120X30 REFRACTORY BR.240X60X30 CHAMFE CAST IRON BRICK 240X60X30 REFRACTORY BR.150X120X30 CHAMF BRICK 150X60X30 CHAMFERED BRICK 180X60X30 CHAMFERED BRICK 150X60X30 CHAMFERED BRICK 180X60X30 CHAMFERED BOTTOM BRICK KIT IF603/604 SILTEMP GRASH HT 4 GR BRICK KIT IF 603-683-743 1996 CAST IRON SET IF 743-44 Description THERMOCONTACT KIT INFIRE RC93 GRILL SUPPORT IF96 + GRILL KIT CAST IRON FIREDOG IF96 STOP AIR IF 96 4-SIDED FRAME IF 604 3-SIDED FRAME IF 603 Imprimé, le 09/05/03 OPCIONES Y RECAMBIOS IF 603 ------------- 37660070 37660071 37660073 37660075 37660076 37660077 MARCO LATON PUERTA 603 EMBELLESEDOR LATON IF603 CESTA CARBON 603 MARCO LUX4C 604 EMBELLESEDOR 4C IF604 MARCO LUX 3C 603 OPTIONS AND SPARE PARTS IF 603 BRASS FRAME FOR DOOR BRASS COVER 3SIDES FRAME IF603 COAL BASKET IF603 96 4 SIDES LUXE FRAME 96 BRASS COVER 4SIDES FRAME IF604 3 SIDES LUX FRAME IF 603 96 Imprimé, le 09/05/03 OPCIONES Y RECAMBIOS IF 683 OPTIONS AND SPARE PARTS IF 683 RECAMBIOS / SPARE PARTS Ref 02 03 04 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 32 33 34 35 36 37 38 39 40 41 42 43 44 45 45 46 46 47 47 48 49 50 52 53 --------- Concepto Code 37117400 07VM0180 37668002 37668072 07RV1035 27668026 37668018 27668043 07Q04002 17660013 03SZA008 27668014 27668015 37115018 07BP0103 17660000 1774P006 27660000 07FTS690 07EVDDA3 27668023 07NB08 37660006 07EEVENC 17660018 17000002 07EEG006 17660011 07MB05 27668016 27668017 37668000 07PBE001 37116241 27668024 27668020 27668019 37668015 37660016 03J706A6 07FFIFG3 07FFIFG2 07CB328 07FF0303 07CB300 07FF0301 07CB313 07FF0302 07CB305 07CB327 07CB313 07CB325 07CB325 07CB7168 07GR03 37674008 37674017 BOQUILLA AIRE CALIENTE DIA 125 EMPALME INOX TUBO CHIM DIAM 180 KIT MARCO RECUBRIMIENTO 3C683 KIT MARCO RECUBRIMIENTO 4C 684 CERAM 565X351X4 IF683/684 CONTRA PUERTA 683 FACHADA MONTADA IF 683 (98) TAPA BASCULANTE IF 683 (98) EJE BISAGRA DIA 6 LG125 MANDO APERTURA PUERTECILLA IF 96 FIX RAPID C2631 ZF (AMARILLO) SEGUNDA TEJA 683 TEJA 683 ATIZADOR MANO FRIA PRISMA SOPORTE PESTILLO 683 PESTILLO PRISMA FIJACION PESTILLO 683 TERMOSTATO TELESCOPICO DIA90 VENTILADOR DDL 76-86 (62-68) MARCO FILTRO 683 FILTRO 157X121X10 ARNES 1996 VARIADOR PARA EMPOTRAR EJE BISAGRA PUERTECILLA IF96 (98) TUERCA SWITCH - CLIP CLAP MICROSWITCH CON PULSADOR AISLANTE SWITCH IF 96 TAPON CAUCHO ICLB 1800-3 DOSIFICADOR AIRE SEGUNDARIO SOPORTE DOSIFICATOR PUERTA CENIZERO IF96 CLIP PUERTA CENIZERO BRAZO LIMPIACENIZA (88) CENIZERO IF 96 DEFLECTOR AIRE 683 REPARTIDOR AIRE 683 PARALENOS IF 683 SOPORTE PARALENOS IF96 TORNILLO SWAGEFORM (TH) M6X12) PARRILLA FUND INFERIOR.LG 300 PARRILLA ACERO CRO.SUP. LG 266 LADRILLO 165X120X30 PLACA FUNDICION 165X120X30 LADRILLO 240X120X30 VT20 PLACA FUNDICION 240X120X30 LADRILLO 240X60X30 BISELADO PLACA FUNDICION 240X60X30 LADRILLO 150X120X30 BISELADO LADRILLO 120X60X30 BISELADO LADRILLO 240X60X30 BISELADO LADRILLO 180X60X30 BISELADO LADRILLO 180X60X30 BISELADO KIT LADRILLOS FONDO 683/684 GRASA SILTEMP HT 4 GR KIT LADRILLOS IF 603-683-743 1996 KIT FUNDICION IF 743/744 OPCIONES / OPTIONS Ref 54 ----------- Code 37680048 17660074 27660029 37660003 37668004 37668005 Concepto KIT THERMOCONTACTO INFIRE RC93 KIT BARBACOA IF 96 KIT PARA LENO FUNDICION STOP AIRE IF 96 MARCO 15 MM 4C IF 684 MARCO 15 MM 3C IF 683 Description HOT AIR PIPE DIA 125 PIPE ADAPTOR DIAM 180 3 SIDES FRAME KIT IF683 96 4 SIDES FRAME IF684 96 CERAM. 565X351X4 IF683/684 ST. STEEL SEAL IF683 1996 ASSEMBLED FACE IF 683 (98) PAINTED TIPPING COVER JOINT PIN DIA 6 LGTH 125 COVER OPENING LEVER IF96 RAPID FASTEN C 2631 ZF (YELLOW TOP BAFFLE IF683 1996 LOW BAFFLE IF683 1996 POKER COLD HANDLE IF96+PRISMA LATCH SUPPORT IF 96 LATCH INFIRE 95 LATCH CATCH IF96 TELESCOPIC THERMOSTAT DIA90 FANS DDL76-86 (62-68) FILTER FRAME INFIRE 96 BULPRENS 157X121X10 ELECTICAL CONNECTION IF96 VARIATOR TO BE INSERTED HINGE AXLE IF 96 (98) SWITCH NUT-CLIP CLAP IF 96 MICROSWITCH WITH BUTTON SWITCH INSULATOR IF 96 COVER NAIL SECONDARY AIR DOSING IF96 DOSING SUPPORT IF96 ASHPAN DOOR IF96 ASHPAN DOOR SPRING D950207 ASH REMOVING ARM (88) ASHPAN IF96 AIR DEFLECTOR IF683 1996 AIR DISTRIBUTER IF683 1996 LOG RETAINER IF 683 LOG RETAINER HOLDER SCREW SWAGEFORM (TH) M6X12 LOWER CAST IRON GRATE LG 300 UPPER STEEL GRATE LG 266 BRICK 165X120X30 CAST IRON BRICK 165X120X30 REFRACTORY BR.240X120X30 VT20 CAST IRON BRICK 240X120X30 REFRACTORY BR.240X60X30 CHAMFE CAST IRON BRICK 240X60X30 REFRACTORY BR.150X120X30 CHAMF BRICK 150X60X30 CHAMFERED REFRACTORY BR.240X60X30 CHAMFE BRICK 180X60X30 CHAMFERED BRICK 180X60X30 CHAMFERED BOTTOM BRICK KIT IF683/684 SILTEMP GRASH HT 4 GR BRICK KIT IF 603-683-743 1996 CAST IRON SET IF 743-44 Description THERMOCONTACT KIT INFIRE RC93 GRILL SUPPORT IF96 + GRILL KIT CAST IRON FIREDOG IF96 STOP AIR IF 96 4-SIDED 15 MM FRAME IF 683 3-SIDED 15 MM FRAME IF 683 Imprimé, le 09/05/03 OPCIONES Y RECAMBIOS IF 683 ------------- 37668070 37668071 37668073 37668075 37668076 37668077 MARCO LATON PUERTA 683 EMBELLESEDOR LATON 683 CESTA CARBON 683 MARCO LUX 4C 684 EMBELLESEDOR LATON 684 MARCO LUX 3C 683 OPTIONS AND SPARE PARTS IF 683 BRASS FRAME FOR DOOR IF683 BRASS COVER 3SIDES FRAME IF683 COAL BASKET IF683 1996 4 SIDES LUXE FRAME 96 BRASS COVER 4SIDES FRAME IF684 3 SIDES LUXE FRAME IF683 1996 Imprimé, le 09/05/03 OPCIONES Y RECAMBIOS IF 743 RECAMBIOS / SPARE PARTS Ref 02 03 04 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 32 33 34 35 36 37 38 39 40 41 42 43 44 45 45 46 46 47 47 48 49 50 51 52 53 --------- Concepto Code 37117400 07VM0180 37674002 37674072 07RV1034 27674026 37674018 27674043 07Q04002 17660013 03SZA008 27674014 27674015 37115018 07BP0103 17660000 1774P006 27660000 07FTS690 07EVDDA3 27668023 07NB08 37660006 07EEVENC 17660018 17000002 07EEG006 17660011 07MB05 27668016 27668017 37668000 07PBE001 37116241 27668024 27674020 27674019 37674015 37660016 03J706A6 07FFIFG3 07FFIFG2 07CB328 07FF0303 07CB300 07FF0301 07CB313 07FF0302 07CB305 07CB326 07CB313 07CB326 07CB325 07CB313 07CB7174 07GR03 37674008 37674017 BOQUILLA AIRE CALIENTE DIA 125 EMPALME INOX TUBO CHIM DIAM 180 KIT MARCO RECUBRIMIENTO 3C 743 KIT MARCO RECUBRIMIENTO 4C 744 CERAM 625X391X4 IF743/744 CONTRA PUERTA 743 FACHADA MONTADA IF 743 PUERTECILLA BASCULANTE IF 743 EJE BISAGRA DIA 6 LG125 MANDO APERTURA PUERTECILLA IF 96 FIX RAPID C2631 ZF (AMARILLO) TEJA SUPERIOR 743 TEJA INFERIOR 743 1996 ATIZADOR MANO FRIA PRISMA SOPORTE PESTILLO 683 PESTILLO PRISMA FIJACION PESTILLO 683 TERMOSTATO TELESCOPICO DIA90 VENTILADOR DDL 76-86 (62-68) MARCO FILTRO 683 FILTRO 157X121X10 ARNES 1996 VARIADOR PARA EMPOTRAR EJE BISAGRA PUERTECILLA IF96 (98) TUERCA SWITCH - CLIP CLAP MICROSWITCH CON PULSADOR AISLANTE SWITCH IF 96 TAPON CAUCHO ICLB 1800-3 DOSIFICADOR AIRE SEGUNDARIO SOPORTE DOSIFICATOR PUERTA CENIZERO IF96 CLIP PUERTA CENIZERO BRAZO LIMPIACENIZA (88) CENIZERO IF 96 DEFLECTOR AIRE 743 REPARTIDOR AIRE 743 PARALENOS IF 743 SOPORTE PARALENOS IF96 TORNILLO SWAGEFORM (TH) M6X12) PARRILLA FUND INFERIOR.LG 300 PARRILLA ACERO CRO.SUP. LG 266 LADRILLO 165X120X30 PLACA FUNDICION 165X120X30 LADRILLO 240X120X30 VT20 PLACA FUNDICION 240X120X30 LADRILLO 240X60X30 BISELADO PLACA FUNDICION 240X60X30 LADRILLO 150X120X30 BISELADO LADRILLO 150X120X60 BISELADO LADRILLO 240X60X30 BISELADO LADRILLO 150X120X60 BISELADO LADRILLO 180X60X30 BISELADO LADRILLO 240X60X30 BISELADO KIT LADRILLOS FONDO 743/744 GRASA SILTEMP HT 4 GR KIT LADRILLOS IF 743/744 1996 KIT FUNDICION IF 743/744 OPCIONES / OPTIONS Ref 54 --------- Code 37680048 17660074 27660029 37660003 37674004 Concepto KIT THERMOCONTACTO INFIRE RC93 KIT BARBACOA IF 96 KIT PARA LENO FUNDICION STOP AIRE IF 96 MARCO 15 MM 4C IF 744 OPTIONS AND SPARE PARTS IF 743 Description HOT AIR PIPE DIA 125 PIPE ADAPTOR DIAM 180 3 SIDES FRAME KIT IF743 96 4 SIDES FRAME KIT IF 743 CERAM.625X391X4 IF74/60 ST. STEEL SEAL IF743 1996 FRONT IF 743 TILTING SCREEN IF 743 JOINT PIN DIA 6 LGTH 125 COVER OPENING LEVER IF96 RAPID FASTEN C 2631 ZF (YELLOW TOP BAFFLE IF743 1996 LOW BAFFLE IF743 1996 POKER COLD HANDLE IF96+PRISMA LATCH SUPPORT IF 96 LATCH INFIRE 95 LATCH CATCH IF96 TELESCOPIC THERMOSTAT DIA90 FANS DDL76-86 (62-68) FILTER FRAME INFIRE 96 BULPRENS 157X121X10 ELECTICAL CONNECTION IF96 VARIATOR TO BE INSERTED HINGE AXLE IF 96 (98) SWITCH NUT-CLIP CLAP IF 96 MICROSWITCH WITH BUTTON SWITCH INSULATOR IF 96 COVER NAIL SECONDARY AIR DOSING IF96 DOSING SUPPORT IF96 ASHPAN DOOR IF96 ASHPAN DOOR SPRING D950207 ASH REMOVING ARM (88) ASHPAN IF96 AIR DEFLECTOR IF743 1996 AIR DISTRIBUTER IF743 1996 LOG RETAINER IF 743 LOG RETAINER HOLDER SCREW SWAGEFORM (TH) M6X12 LOWER CAST IRON GRATE LG 300 UPPER STEEL GRATE LG 266 BRICK 165X120X30 CAST IRON BRICK 165X120X30 REFRACTORY BR.240X120X30 VT20 CAST IRON BRICK 240X120X30 REFRACTORY BR.240X60X30 CHAMFE CAST IRON BRICK 240X60X30 REFRACTORY BR.150X120X30 CHAMF BRICK 150X60X30 CHAMFERED REFRACTORY BR.240X60X30 CHAMFE BRICK 150X60X30 CHAMFERED BRICK 180X60X30 CHAMFERED REFRACTORY BR.240X60X30 CHAMFE BOTTOM BRICK KIT IF743/744 SILTEMP GRASH HT 4 GR BRICK KIT IF 743/744 1996 CAST IRON SET IF 743-44 Description THERMOCONTACT KIT INFIRE RC93 GRILL SUPPORT IF96 + GRILL KIT CAST IRON FIREDOG IF96 STOP AIR IF 96 4-SIDED FRAME 15MM IF 744 Imprimé, le 26/08/02 OPCIONES Y RECAMBIOS IF 743 --------------- 37674005 37674070 37674071 37674073 37674075 37674076 37674077 MARCO 15 MM 3C IF 743 MARCO LATON CRISTAL IF 743 EMBELLESEDOR LATON 743 CESTA CARBON 743 MARCO LUX 4 C 744 EMBELLESOR LATON 744 MARCO LUX 3 C IF 743 1996 OPTIONS AND SPARE PARTS IF 743 4-SIDED FRAME IF 743 BRASS FRAME FOR DOOR IF743 BRASS COVER 3SIDES FRAME IF743 COAL BASKET IF743 1996 4 SIDES LUXE FRAME 1996 BRASS COVER 4SIDES FRAME IF743 3 SIDES LUXE FRAME IF743 1996 Imprimé, le 26/08/02