DataGator - Waterford Systems
Transcription
DataGator - Waterford Systems
A Novel and Accurate Flow Metering Technique for Open Channel and Full Pipe Flows in Sewers and Plant Effluent Discharge Pipes Raj Natarajan OUTLINE 1. Introduction 2. Flow Conditions in Sewer and Effluent Pipes 3. Existing Flow Measurement Technologies and Their Shortcomings 4. DataGator Flowmeter Design Concept 5. Laboratory Flow Calibration 6. System Test and Flow Measurement Accuracy 7. Conclusions Flow Conditions in Sewer and Effluent Pipes Open Channel ___ Free Flow Submerged Flow Surcharged Flow Full Pipe Flow ___ Without Surcharge With Surcharge Flow Direction ___ Both Forward and Reverse Open Channel – Free Flow Open Channel – Submerged Flow (backwater Condition) Full Pipe Flow Surcharged Flow (Flooded Manhole) Existing Flow Meter Technologies Full Pipe Flow Only Orifice Plate / Differential Pressure Ultrasonic – Doppler Flow Meter Electromagnetic Flow Meter (Magmeter) Vortex Flow Meter Venturi Tubes Most Industrial Flow Meters Open Chennel (Partial Pipe Flow) Only Flumes Wiers Open Channel AND Full Pipe Area-Velocity Meters DataGator Flow Meter Existing Flow Meter Technologies Flumes (Level Only Meters) • • • • Accuracy depends on the level measurement instrumentation CANNOT be used for Full Pipe, Surcharged and/or Reverse flow Conditions Silt build up at the bottom overestimates flow Does not work for in-line applications Existing Flow Meter Technologies Area Velocity Meters Principle of Operation: Flow = Velocity X Area • Can Measure Open Channel Free Flow and Full Pipe Without Surcharge • Surcharge Flow Measurements are Inaccurate, If Not Impossible • Average velocity of the Flow Profile is Arrived at Using A Single Point Velocity Measurement. Assumptions Used for This Conversion is NOT True for All Flow Situations. This Causes Large Errors in Velocity and Hence in Flow • To Reduce the Above Problem, an Elaborate In-Situ Calibration is Required. U.S. Government Compares Flowmeters Marsh-McBirney, Inc. Water & Wastes Digest September 1997 A comparison of open channel flowmeter response to one of 50 storm events. These results are typical of those obtained during extensive testing by the U.S. Government. This graphic compares magnetic and Doppler velocity sensing techniques using a a Calibrated Flume as the bench mark for measurement in the open channel flow condition. The DataGator Flow Metering System uses a calibrated flume/modified Venturi tube as its primary element for flow measurement. The only real difference between the DataGator and the U.S. Government bench mark is that the DataGator yields similar results under all possible flow conditionsopen channel, full pipe, submerged, surcharged and reverse. NIST traceable accuracy with absolutely no on-site calibration or flow profiling! Independent Comparison DataGator Flow Metering System and Velocity/Area Meter 8 inch flow loop Measurement Technique: Velocity/Area Meter: Q = V x A Velocity/Area DataGator Meter Primary sensors: Level - Pressure transducer Velocity - Magnetic principle DataGator Flow Metering System: Inline Flowmeter Pressure to flow conversion in a pre-calibrated flow tube Primary Sensors: Three high accuracy pressure transducers 8 inch pre-calibrated flow tube Performance: (All readings in GPM) Velocity/Area Actual 44.7 88.2 102.5 Throat Transducer Indicated 151.0 225.0 300.0 DataGator Actual 44.7 88.2 102.5 Indicated 46.5 89.6 99.8 After repositioning the velocity and level sensors and calibrating the system (1 hour 15 minutes) using readings from the inline and DataGator flow meters, Inlet Transducer Outlet Transducer the velocity/area unit did provide accurate readings under open channel flow conditions. The DataGator required no calibration or flow profiling. DataGator FLOWMETER DESIGN CONCEPT Combination of Two Proven Flow Measurement Techniques: Open Channel ___ Flume Full Pipe ___ Venturi Tubes DataGator -- Venturi Flume with Patented Throat Design • Conventional Venturi Flumes Suffered a Discontuinity in Flow Measurement at Transition From Open to Full Pipe Flow • DataGator Throat Design Provides a Sill That Achieves a Simultaneous Filling of the Throat and the Upstream Pipe. Hence NO DISCONTINUITY in Flow Measurement at Transition from Open to Full Pipe Flow. DataGator Flow Tube Design DataGator Flow Tube Design FLOW DataGator -- OPEN CHANNEL FLOW This Flowmeter is Designed Such That, 1.The Constriction at the Throat of the Flowmeter is Just Enough to Cause Critical Depth to Occur at the Throat Region, and 2.A Sill at the Top of the Throat Provides the Condition for Simultaneous Filling of the Throat and the Upstream Pipe. Under These Conditions, Open Channel Flow is Given by, Y1 + (V12 /2g) = Z + Yc + (Vc2 /2g) + hl, and Q = [ (A23 /T) * g] ½ g Y1 Yc Z A1,A2 T hl = = = = = = = Acceleration Due to Gravity Inlet Depth of Flow Throat Depth of Flow Throat Sill Height Inlet, Throat Area of Flow Top Width of Flow in Throat Head Loss DataGator -- FULL PIPE FLOW DataGator Functions Like a Venturi Tube During Full Pipe Flow. Hence, Q = [2g (Y1 – Y2)] ½ * A1 / [(A1/ A2)2 –1] ½ Q , the Flow rate, With and Without Surcharge is Dependent Only on the Differential Pressure Between Inlet and Outlet. Flow Tube Calibration Data University Of Utah Water Research Lab, Logan, Utah Flow Tube Calibration Data University Of Utah Water Research Lab, Logan, Utah DataGator – Flow Data From Customer Site DataGator – Flow Data From Customer Site DataGator – Flow Data From Customer Site DataGator – Flow Data From Customer Site DataGator – Flow Data From Customer Site DataGator – Installed in a Manhole DataGator – Spool Piece installation DataGator – Spool Piece installation DataGator – Installations DataGator – Installations DataGator – Installations CONCLUSIONS 1. DataGator Flowmeter Measures Flow Rate for All Flow Conditions in an Effluent Pipe or in Sewer Flow Applications. 2. No In-Situ Calibration Required 3. NIST Traceable Accuracy Readily Accepted by Wastewater Treatment Authorities Billing Purposes 4. CALCUflow Software Generates Reports and Graphs for Submission to Authorities. Other Services Available from Renaissance Instruments • • • • • • Installation and start up of DataGator On-site training System Integration – Hardware and Software Inflow and Infiltration studies Inflow and Infiltration remediation Recommendations Implementation Engineering Consulting Services