Insulation for Ventilated Rainscreen Cladding Systems
Transcription
Insulation for Ventilated Rainscreen Cladding Systems
Insulation Third Issue September 2010 Insulation for Ventilated Rainscreen Cladding Systems COMPLIANCE WITH APPROVED DOCUMENT B2 Low Energy Low Carbon Buildings Insulation for Ventilated Rainscreen Systems Four Steps to Compliance This Technical Bulletin details the route to compliance with Approved Document B2 to the Building Regulations for insulated rainscreen cladding systems fixed to new and existing steel framed or masonry walls. The requirements differ for constructions used in buildings: ● less than 18 metres in height; and ● 18 metres or more in height. Referring to Approved Document B2 Buildings other than dwellinghouses (2006 edition), amended 2007, the reader is directed as follows for guidance given in relation to the application of insulation materials: Figure 1 Buildings less than 18 metres in height with a non-combustible substrate Step 1 Please refer to Section 9 Table 13 Maximum Dimensions of cavities in non-domestic buildings (Purpose Group 2-7) (Figure 1). Step 2 Please refer to Section 9 paragraph 9.3 Junctions and cavity closures (Figure 2). Figure 2 In addition, cavity barriers should be provided to close the edge of cavities, including those around all openings. Cavity barriers also need to be provided at the junction with an internal wall or floor which is forming a fire resisting barrier. N.B. Kingspan Kooltherm® K15 Rainscreen Board should not be installed directly to steel framing. For buldings less than 18 metres in height, as Kingspan Kooltherm® K15 Rainscreen Board is classified by the Building Regulations as being Class 0, it complies with the requirements of Approved Document B2 if the maximum dimensions in any direction between cavity barriers is 20 metres. 2 Buildings 18 metres or more in height The following relates only to storeys at a height of 18 metres or greater. Step 3 In addition to Steps 1 and 2, due to the nature of the construction, please refer to Section 12 paragraph 12.5 External wall construction (Figure 3). Step 4 Refer to the guidance given in BR 135 for a building with a storey 18 metres or more above ground level (Figure 4). Figure 3 Figure 4 In addition, cavity barriers should be provided to close the edge of cavities, including those around all openings. Cavity barriers also need to be provided at the junction with an internal wall or floor which is forming a fire resisting barrier. N.B. Kingspan Kooltherm® K15 Rainscreen Board should not be installed directly to steel framing. For buldings of 18 metres or more in height, as Kingspan Kooltherm® K15 Rainscreen Board meets the BR 135 performance criteria when tested to BS 8414-1: 2002 with horizontal cavity barriers at a 3.5 metre vertical separation, Kingspan Kooltherm® K15 Rainscreen Board complies with the requirements of Approved Document B2 if installed on the outside of a non-combustible substrate i.e. calcium silicate board or masonry and the maximum vertical distance between cavity barriers is 3.5 metres. In the event the floor spacing is less than 3.5 metres cavity barriers should be provided at every floor level. 3 Kingspan Kooltherm® K15 Rainscreen Board is the first insulation board to achieve LABC Type Approval as a thermal insulation layer in rainscreen cladding systems. It remains the only insulation board that holds both BBA Certification and LABC Type Approval. Certificate No. 452-7-7194 LABC Type Approval is issued by one local authority and is accepted by all other local authorities throughout England and Wales. LABC Type Approvals cover compliance with the Building Regulations and a register of Approvals is kept by LABC to which local authority building control officers can refer. This LABC Type Approval thus eases the planning process for projects incorporating Kingspan Kooltherm® K15 Rainscreen Board, and applies in all situations shown on Diagram 40 of Approved Document B Volume 2, including those parts of a building more than 18m above ground (Figure 5). Kingspan Kooltherm® K15 Rainscreen Board is a premium performance rigid thermoset insulation board for use in ventilated rainscreen cladding systems. Figure 5 For technical guidance please contact the Kingspan Insulation Technical Services Department (see rear cover). 4 Contact Details Customer Service Technical Advice / Design For quotations, order placement and details of despatches please contact the Kingspan Insulation Customer Service Department on the numbers below: Kingspan Insulation supports all of its products with a comprehensive Technical Advisory Service for specifiers, stockists and contractors. Tel: +44 (0) 1544 388 601 Fax: +44 (0) 1544 388 888 email: [email protected] Literature & Samples Kingspan Insulation produces a comprehensive range of technical literature for specifiers, contractors, stockists and end users. The literature contains clear ‘user friendly’ advice on typical design; design considerations; thermal properties; sitework and product data. Available as a complete Design Manual or as individual product brochures, Kingspan Insulation technical literature is an essential specification tool. For copies please contact the Kingspan Insulation Marketing Department on the numbers below: Tel: +44 (0) 1544 387 384 Fax: +44 (0) 1544 387 484 email: [email protected] This includes a computer–aided service designed to give fast, accurate technical advice. Simply phone the Kingspan Insulation Technical Service Department with your project specification. Calculations can be carried out to provide U–values, condensation / dew point risk, required insulation thicknesses etc… Thereafter any number of permutations can be provided to help you achieve your desired targets. The Kingspan Insulation Technical Service Department can also give general application advice and advice on design detailing and fixing etc... Site surveys are also undertaken as appropriate. Please contact the Kingspan Insulation Technical Service Department on the numbers below: Tel: +44 (0) 1544 387 382 Fax: +44 (0) 1544 387 482 email: [email protected] General Enquiries For all other enquiries contact Kingspan Insulation on the numbers below: Tel: +44 (0) 1544 388 601 Fax: +44 (0) 1544 388 888 email: [email protected] Tapered Roofing For technical guidance, quotations, order placement and details of despatches please contact the Kingspan Insulation Tapered Roofing Department on the numbers below: Tel: +44 (0) 1544 387 383 Fax: +44 (0) 1544 387 483 email: [email protected] Kingspan Insulation Ltd. reserves the right to amend product specifications without prior notice. Product thicknesses shown in this document should not be taken as being available ex–stock and reference should be made to the current Kingspan Insulation price–list or advice sought from Kingspan Insulation’s Customer Service Department (see above left). The information, technical details and fixing instructions etc. included in this literature are given in good faith and apply to uses described. Recommendations for use should be verified as to the suitability and compliance with actual requirements, specifications and any applicable laws and regulations. For other applications or conditions of use, Kingspan Insulation offers a Technical Advisory Service (see above) the advice of which should be sought for uses of Kingspan Insulation products that are not specifically described herein. Please check that your copy of the literature is current by contacting the Kingspan Insulation Marketing Department (see left). Kingspan Insulation Ltd is a member of: The National Insulation Association (NIA) Kingspan Insulation Ltd Pembridge, Leominster, Herefordshire HR6 9LA, UK www.insulation.kingspan.co.uk ® Kingspan, Kooltherm and the Lion Device are Registered Trademarks of the Kingspan Group plc in the UK and other countries. All rights reserved. Registered in England & Wales, No. 01882722. Registered Office: Pembridge, Leominster, Herefordshire HR6 9LA UK. VAT GB428602456
Similar documents
28/4834 KDuct CPR / CE Tech Note v7.indd
herein. Recommendations for use should be verified as to the suitability and compliance with actual requirements, specifications and any applicable codes, laws and regulations. For other applicatio...
More informationOPTIM-R Rainscreen System
performance next generation insulation solution from Kingspan Insulation. It comprises of rigid vacuum insulation panels with a microporous core which is evacuated, encased and sealed in a thin, ga...
More information