Valutek Sterile Nitrile Cleanroom 12” Glove

Transcription

Valutek Sterile Nitrile Cleanroom 12” Glove
VV AA LL UU TT EE KK DD AA TT AA SS HH EE EE TT | G L O V E S
Valutek Sterile Nitrile Cleanroom 12” Glove
Part Number: VTGNCRBIR12
Description: Valutek’s 12” ambidextrous sterile nitrile cleanroom glove is
constructed from 100% synthetic nitrile polymer. This glove
contains no natural rubber latex, is silicone free and has a
textured fingertip design with beaded long cuff. This glove is
packaged in a cleanroom compatible plastic pouch. All Valutek
gloves are tested and manufactured in ISO compliant facilities
under Valutek inspection and strict process control to ensure
Valutek quality standards and product specifications.
Features:
Clean, synthetic nitrile polymer material (Acrylonitrile Butadiene)
Gamma irradiated
12”/290mm length with beaded long cuff
Textured fingertips
Powder-free, double chlorination, 18 megaohm D.I water rinse
Low levels of particles and extractable counts
ESD compliant, acid and solvent compatible
Application: As part of the Valutek Nanotek product family, this product is recommended for use in a clean-
room Class 1-10 (ISO 3-4) critical environment. It is also commonly used in sterile environments
and industries that require a very clean glove such as pharmaceutical, biotechnology, and medical device manufacturing.
VTGNCRBIR12 Packaging
1 pair/pack, 10 pairs/master Pack, 20 master packs/case, 200 pairs/case.
Critical environment compatible. All gloves are lot traceable with retention samples held in Quality
Control for 36 months from date of manufacturing.
Valutek West
USA-Phoenix.AZ
Valutek East
USA-Albany.NY
p 800.763.1250
Valutek Asia Sdn. Bhd
Malaysia
f 602.252.1972
Valutek P.R.C.
China
Valutek Latam
Puerto Rico
[email protected]
www.valutek.com
INNOVATIVE SOLUTIONS FOR CRITICAL ENVIRONMENTS
VA LU T E K DATA S H E E T | G LOV ES
Valutek Sterile Nitrile Cleanroom 12” Glove
Part Number: VTGNCRBIR12
VTGNCRBIR12 Physical Properties
Part Number
Size
Palm Width
(mm)
Weight (gm)
Length (inch/mm)
VTGNCRBIR12-XS
VTGNCRBIR12-SM
VTGNCRBIR12-MD
VTGNCRBIR12-LG
VTGNCRBIR12-XL
VTGNCRBIR12-2X
XS
SM
MD
LG
XL
2X
77 ± 3
83 ± 3
95 ± 3
106 ± 3
112 ± 3
118 ± 3
5.5 ± 0.2
6.0 ± 0.2
6.5 ± 0.2
7.0 ± 0.2
7.5 ± 0.2
8.0 ± 0.2
12”/290
Tensile
Strength
Ultimate
Elongation
Before Aging
18 MPa, min
500%, min
After Aging
18 MPa, min
450%, min
Tensile
Properties
Test Method
ASTM D412
Measured
Points
Fingertip
Palm
Cuff
Test Method
IEST-RP-CC005.4
ASTM D3767
Test Method
Thickness
5.9 mil
0.15 mm
4.72 mil
0.12 mm
3.94 mil
0.10 mm
ASTM D3767
*AQL Sampling Plan: AQL 1.5 Pinhole defect, AQL 2.5 Visual major defect, AQL 4.0 Visual minor defect.
VTGNCRBIR12 Technical Performance
Attribute
Value
Units
Test Method
<800
particles/cm2
IEST-RP-CC005.4, Sec 16.4
<2.0
<5.0
μg/cm2
μg/cm2
IEST-RP-CC005.4, Sec 17.2
IEST-RP-CC005.4, Sec 17.2
Particle Counts
LPC: ≥0.5 µm
Non Volatile Residue (NVR)
DI Water
IPA
FTIR
Silicone Oil, Amide, DOP
Extractable Counts (Ions)
Sodium(Na)
Potassium(K)
Calcium(Ca)
Magnesium(Mg)
Ammonium(NH4+)
Nitrate(NO3-)
Lithium(Li)
Zinc(Zn)
Copper(Cu)
ESD Properties
Electrostatic Decay
Surface resistivity
Wipers
Version v 2.0
Apparel
<0.02
<0.02
<0.40
<0.005
<0.005
<0.40
<0.005
<0.10
<0.0004
IEST-RP-CC005.4, Sec 17.4
Not Detectable
μg/cm2
μg/cm2
μg/cm2
μg/cm2
μg/cm2
μg/cm2
μg/cm2
μg/cm2
μg/cm2
seconds
<5
< 1 X 1011 Ω-2
Gloves
Aluminium(Al)
Iron(Fe)
<0.001
<0.001
<0.002
<0.50
<0.20
<0.001
<0.01
<0.005
μg/cm2
μg/cm2
μg/cm2
μg/cm2
μg/cm2
μg/cm2
μg/cm2
μg/cm2
Tribo Charge
50
v
Fluoride(F-)
Bromide(Br-)
Phosphate(PO43-)
Chloride(Cl-)
Sulfate(SO42-)
Nitrite(NO2−)
Glove Liners
Adhesive Mats
IEST-RP-CC005.4, Sec 17
ANSI/ESD SP15.1
Cleaning &
Maintenance
Documentation
ESD
www.valutek.com