Bi-Wire Fire System
Transcription
Bi-Wire Fire System
cfs0038_R1_Bi-Wire-4-page-leaflet_Layout 1 26/05/2011 15:26 Page 1 Bi-Wire Fire System Dual LED Indicator Saves both time and cost No requirement for separate sounder circuits Zone 1 Zone 2 Zone 3 Zone 4 • BS5839 Part 6 HMO compliant (4 & 8 zone) • Multi-Mode detector • ‘Self-Check’ technology • Improved functionality • Significant cost saving Cooper Patented Technology Bi-Wire UK Patent: GB2293257 Self-Check European Patent: EP:02253889.6 cfs0038_R1_Bi-Wire-4-page-leaflet_Layout 1 26/05/2011 15:26 Page 2 Bi-Wire Control Panels FX2200BW Range Overview Benefits The patented ‘Self-Check’ technology, integrated into the range of Bi-Wire panels, gives the panels the facility to flash all detector LED’s in a specified zone to indicate the location of any wiring fault in that zone, thereby simplifying the fault finding process. • BS5839 Pt 1 & 6 4 & 8 zone panel The 4 and 8 zone panels within the range now provide enhanced features, which include a HMO facility on each zone via a discreet DIP switch. If a zone has been programmed for HMO operation, any fire occurring within that zone will activate the zone fire LED and only the sounders within that zone. Providing the fire condition and affected detector smoke chamber is cleared within 2 minutes, the panel will reset automatically. If no reset occurs, the sounders, strobes and relays will be activated on all zones. • Supports up to 20 detectors and 20 outputs (sounders, LED beacons and relay modules) per zone • Time saving simplified fault finding procedure • The only conventional panel with ‘Internal’ detector fault monitoring • Weekly ‘end user’ test • Simple panel installation • Reduced wiring requirements provide savings in both installation and cost Bi-Wire Repeater Panel FXRP2200BW Overview Benefits The Bi-Wire range repeater panel provides a quick, cost effective method of providing system status information in key areas remote from the main control panel. It is available for connection to the 4 & 8 zone Bi-Wire control panels. • Matches the main panel • Requires only a single pair of wires to receive signals from main panel, plus local mains power supply, reducing cost of installation • Displays essential information at other key locations: - Zone fire and fault conditions - Test mode in operation - Zones or outputs in disabled mode cfs0038_R1_Bi-Wire-4-page-leaflet_Layout 1 26/05/2011 15:26 Page 3 Bi-Wire Multi-Mode Detector FXN922 Solid Amber LED Is continuous to indicate smoke sensing chamber fault or the detector has reached its limit of contamination Flashing Amber LED Can also be pulsed from the panel to help locate wiring faults Solid Red LED Is continuous to indicate that the detector is in alarm condition Overview Benefits The unique Bi-Wire conventional, 5 in 1, ‘Self-Check’ detector is designed and manufactured to provide peace of mind. One of the major benefits of the ‘SelfCheck’ detector is it’s ability to inform the end user when a detector has ceased to function correctly or indeed has failed. 5 modes that are simple to configure: • Optical • Optical/heat • Heat detector (1 of 3 modes) The detector has been designed to monitor itself for any internal fault condition or failure. Should a problem be detected, a zone fault will be generated at the panel and the detector LED will light (amber segment) indicating both zone and device. To aid contractors and service providers detectors in all zones can be instructed, from the panel, to pulse their LED (amber segment) every 2 seconds. This facility can then be used help to locate wiring faults on a zone’s wiring thereby saving both time and labour. - Rate of rise (A1R) - Fixed 77° (BS) - Fixed 92° (CS) ‘The only conventional detector to talk to the panel’ Bi-Wire Starter Kits FX2ZBWKIT / FX4ZBWHMOKIT Everything you need for a system installation 2 Zone Bi-Wire Kit 4 Zone Bi-Wire Kit • 1 x 2 Zone Panel • 1 x 4 Zone Panel • 6 x Detectors • 10 x Detectors • 4 x Bases • 6 x Bases • 2 x Sounder Bases • 4 x Sounder Bases • 2 x Callpoint • 4 x Callpoint e Kit 4 Zon laint Comp HMO cfs0038_R1_Bi-Wire-4-page-leaflet_Layout 1 26/05/2011 15:26 Page 4 Product Codes Bi-Wire Accessories Bi-Wire Control Panels Callpoints FX2202BW 2-Zone Panel • ‘Quick-Fit’ clip-fixed front cover FX2204BWHMO 4-Zone Panel • One key for test and cover removal FX2208BWHMO 8-Zone Panel Bi-Wire Repeater Panel Electronic Sounders FXRP2200BW • Ultra low current Repeater Panel Detectors and Detector Bases • High sound output FXN922 Multi-Mode Detector • Volume control FXN520 Standard Base • Lockable base FXN521BWS Sounder Base FXN521BWB Beacon Base FXN521BWSB Sounder Beacon Base FXN538COV Cover for Bases • Low current FX201 Flush/Surface Callpoint • Can be used as a stand-alone sounder, beacon or sounder beacon FX203 Weatherproof Callpoint CXPC Plastic Front Cover (Pk of 10) FX5G Spare Glasses (Pk of 5) FX009 Wall Sounder FXN004BW LED Beacon • High output LED beacon FXN01124V 24V dc Relay Module • Low current FXN011230 230V ac Relay Module Relay Modules Accessories Detector Bases • Integrated detector base • With detector fitted, one location for detection and alarm output LED Beacon Bi-Wire Starter Kits FX2ZBWKIT Bi-Wire 2 Zone Starter Kit FX4ZBWHMOKIT Bi-Wire 4 Zone Starter Kit • Connects on zone wiring • Relay operates on any fire activation Cooper Safety Fire Systems Cooper Lighting and Safety Ltd, Wheatley Hall Road, Doncaster, South Yorkshire, DN2 4NB. www.cooperfire.com Sales T: +44 (0)1302 303 999 F: +44 (0)1302 303 333 E: [email protected] Technical and Quotations T: +44 (0)1302 303 350 F: +44 (0)1302 303 332 E: [email protected] ®2010 Cooper Lighting and Safety. All rights reserved. Publication reference: CFS0038-BW4 Export T: +44 (0)1302 303 344 F: +44 (0)1302 303 345 E: [email protected] Awarded to: Cooper Industries (UK) Ltd